Alternative Devices for Taking Insulin

Similar documents
What I need to know about Diabetes Medicines

What do diabetes medicines do?

Design of Insulin Watch

The A1C Test and Diabetes

Am I at Risk for Type 2 Diabetes? Taking Steps to Lower Your Risk of Getting Diabetes

Insulin Pump Therapy

Policy for the safe administration of Insulin

Technology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE

Diagnosis of Diabetes

A Fact Sheet for Parents and Carers Insulin and Diabetes

Zollinger-Ellison Syndrome

Insulin Pump An information session to help you decide if you are ready to use an insulin pump.

Diagnosis of Diabetes National Diabetes Information Clearinghouse

Virtual Colonoscopy. National Digestive Diseases Information Clearinghouse

flow resulting from damage to blood vessels can also contribute to sexual dysfunction.

People with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT

DISCOVER THE POWER OF CONNECTION MINIMED 640G

Predicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY

DISCOVER THE POWER OF CONNECTION MINIMED 640G

Am I at Risk for Type 2 Diabetes?

DIABETES - FACT SHEET

National Digestive Diseases Information Clearinghouse

INSULIN INJECTION KNOW-HOW

10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:

Spring - A Patch Pump Without a Motor. Presented at ATTD 2011 by Hezkiah Tsoory, COO D-Medical/Spring

Flexible Sigmoidoscopy

Prediabetes and Diabetes Prevention Resources

National Kidney and Urologic Diseases Information Clearinghouse

Gas. What I need to know about. U.S. Department of Health and Human Services

Design and Analysis of Automatic Insulin Delivery System Using Pic Microcontroller

Liver Biopsy. National Digestive Diseases Information Clearinghouse

NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP

Insulin Pump Therapy. WakeMed Children s Endocrinology & Diabetes WakeMed Health & Hospitals Version 1.3, rev 5/21/13 MP

Autopen 24 is an easy to use insulin injection pen, designed for use with 3.0ml sanofi aventis insulin cartridges. Compatible with all pen needles*.

Colonoscopy. National Digestive Diseases Information Clearinghouse

Diabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE

WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES?

UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE

WHEN YOUR PANCREAS IS NOT A HAPPY CAMPER A PRESENTATION ON DIABETES MANAGEMENT IN THE CAMP SETTING AMANDA COSCHI, BSCN, RN, CDE

RELEASED. first steps. Icon Icon name What it means

Lower GI Series. National Digestive Diseases Information Clearinghouse

Monitoring of Blood Glucose Level

Digestive Diseases Statistics for the United States

National Digestive Diseases Information Clearinghouse

Diet for Kidney Stone Prevention

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes

DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson

Much of what is written on insulin pump use is biased in favor of insulin pump manufacturers.

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

Diabetes Medical Management Plan

Nonalcoholic Steatohepatitis National Digestive Diseases Information Clearinghouse

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

MiniMed 640G System Intelligent for Better Control

Date of Diabetes diagnosis Type I Type II. School Nurse Phone. Mother/Guardian. Address. Home phone Work Cell. Father/Guardian.

JDRF RESEARCH UPDATE. Daniel Finan, Ph.D. Research Director

GET TO KNOW YOUR PEN. Needle cap. Rubber seal. Insulin scale. Pen cap. Cartridge holder Plunger. Insulin name. Dose window Dose. pointer.

More Than 1 Year of Hybrid Closed Loop in Pediatrics. Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center

Important information on the Accu-Chek Insight insulin pump system: Update of the handling instructions for changing an insulin cartridge

AN INTRODUCTION TO YPSODOSE FOR THE LARGE-VOLUME INJECTION OF BIOLOGICS

PLEASE READ THIS USER MANUAL BEFORE USE

Getting you up to speed Quick Reference Guide

1. Continuous Glucose Monitoring

USER GUIDE BEST LIFE Insulin Pump

Diabetes: Prevention, Diagnosis, Treatment and Self-Management

MiniMed 640G System Intelligent for Better Control

MONMOUTH COUNTY VOCATIONAL SCHOOLS

Pump Mechanics and Management. Basic procedures for initiating pump therapy

The pump that gets updated, not outdated. *

GETTING STARTED WITH THE MINIMED 640G SYSTEM

Caregiver Guide WITH THE OMNIPOD. MyOmniPod.com RYAN OMNIPOD WEARER

Diabetes Medical Management Plan

Pancreatitis. Acute Pancreatitis

Diabetes Medical Management Plan/Individualized Healthcare Plan. Part A: Contact Information must be completed by the parent/guardian.

National Kidney and Urologic Diseases Information Clearinghouse (NKUDIC)

Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

FREEHOLD REGIONAL HIGH SCHOOL DISTRICT. Parents/Guardian of

National Digestive Diseases Information Clearinghouse

Pump Basics for the School Nurse. Children's Endocrinology Center of Dallas

Lilly. Disposable Insulin Delivery Device User Manual

Pump Failure Guidelines

COPYRIGHTED MATERIAL. Chapter 1 An Introduction to Insulin Pump Therapy WHAT IS INSULIN PUMP THERAPY?

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

DIABETES MANAGEMENT PLAN 2017

Approved by: Integrated Health Quality Management Subcommittee Effective Date: Department of Origin: Integrated Healthcare Services.

The design of an insulin pump preliminary requirements (a technical note)

DONGBAO PEN (ELECTRONIC) INSTRUCTION MANUAL

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

VICTORIA INDEPENDENT SCHOOL DISTRICT Diabetes Medical Management Plan

DIABETIC MANAGEMENT PLAN

HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

DIABETES & ENDOCRINE DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT

Diabetes Medical Management Plan (DMMP)

Insulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education

GLOOKO DREAMED FOR ANDROID USER GUIDE

Transcription:

Alternative Devices for Taking Insulin Many people with diabetes must take insulin to manage their disease. Most people who take insulin use a needle and syringe to inject insulin just under the skin. Several other devices for taking insulin are available and new approaches are under development. No matter which approach a person uses for taking insulin, consistent monitoring of blood glucose levels is important. Good blood glucose control can prevent complications of diabetes. Most people who take insulin use a needle and syringe to inject insulin just under the skin. What alternative devices for taking insulin are available? Insulin pens provide a convenient, easy-to-use way of injecting insulin and may be less painful than a standard needle and syringe. An insulin pen looks like a pen with a cartridge. Some of these devices use replaceable cartridges of insulin. Other pens are prefilled with insulin and are totally disposable after the insulin is injected. Insulin pen users screw a short, fine, disposable needle on the tip of the pen before an injection. Then users turn a dial to select the desired dose of insulin, inject the needle, and press a plunger on the end to deliver the insulin just under the skin. Insulin pens are less widely used in the United States than in many other countries. Insulin pens are a convenient alternative to a needle and syringe for insulin injections. External insulin pumps are typically about the size of a deck of cards or cell phone, weigh about 3 ounces, and can be worn on a belt or carried in a pocket. Most pumps use a disposable plastic cartridge as an insulin reservoir. A needle and plunger are temporarily attached to the cartridge to allow the user to fill the cartridge with insulin

from a vial. The user then removes the needle and plunger and loads the filled cartridge into the pump. Insulin pumps contain enough insulin for several days. An infusion set carries insulin from the pump to the body through flexible plastic tubing and a soft tube or needle inserted under the skin. Disposable infusion sets are used with insulin pumps to deliver insulin to an infusion site on the body, such as the abdomen. Infusion sets include a cannula a needle or a small, soft tube that the user inserts into the tissue beneath the skin. Devices are available to help insert the cannula. Narrow, flexible plastic tubing carries insulin from the pump to the infusion site. On the skin s surface, an adhesive patch or dressing holds the infusion set in place until the user replaces it after a few days. Users set the pumps to give a steady trickle or basal amount of insulin continuously throughout the day. Pumps can also give bolus doses one-time larger doses of insulin at meals and at times when blood glucose is too high based on the programming set by the user. Frequent blood glucose monitoring is essential to determine insulin dosages and to ensure that insulin is delivered. Injection ports provide an alternative to daily injections. Injection ports look like infusion sets without the long tubing. Like infusion sets, injection ports have a cannula that is inserted into the tissue beneath the skin. On the skin s surface, an adhesive patch or dressing holds the port in place. The user injects insulin through the port with a needle and syringe or an insulin pen. The port remains in place for several days and is then replaced. Use of an injection port allows a person to reduce the number of skin punctures to one every few days to apply a new port.

Using an injection port reduces the number of skin punctures to one every few days to apply a new port. The user injects insulin through the port. Injection aids are devices that help users give injections with needles and syringes through the use of spring-loaded syringe holders or stabilizing guides. Many injection aids have a button the user pushes to inject the insulin. Insulin jet injectors send a fine spray of insulin into the skin at high pressure instead of using a needle to deliver the insulin. What are the prospects for an artificial pancreas? To overcome the limitations of current insulin therapy, researchers have long sought to link glucose monitoring and insulin delivery by developing an artificial pancreas. An artificial pancreas is a system that will mimic, as closely as possible, the way a healthy pancreas detects changes in blood glucose levels and responds automatically to secrete appropriate amounts of insulin. Although not a cure, an artificial pancreas has the potential to significantly improve diabetes care and management and to reduce the burden of monitoring and managing blood glucose. An artificial pancreas based on mechanical devices requires at least three components: a continuous glucose monitoring (CGM) system an insulin delivery system a computer program that adjusts insulin delivery based on changes in glucose levels CGM systems approved by the U.S. Food and Drug Administration (FDA) include those made by Abbott, DexCom, and Medtronic. A CGM system paired with an insulin pump is available from Medtronic. This integrated system, called the MiniMed Paradigm REAL-Time System, is not an artificial pancreas, but it does represent the first step in joining glucose monitoring and insulin delivery systems using the most advanced technology available. Points to Remember Many people with diabetes who need insulin use a needle and syringe to inject insulin under the skin.

The most common alternative ways to deliver insulin are insulin pens and insulin pumps. Injection ports, injection aids, and insulin jet injectors are also available. Researchers are developing an artificial pancreas, a system of mechanical devices that will automatically adjust insulin delivery based on changes in glucose levels. People who take insulin should monitor their blood glucose levels regularly. Good glucose control can prevent complications of diabetes. Hope through Research Research supported by the National Institute of Diabetes and Digestive and Kidney Diseases and the National Institutes of Health is contributing to the development of new technologies for continuous glucose monitoring, insulin delivery, and an artificial pancreas. Participants in clinical trials can play a more active role in their own health care, gain access to new research treatments before they are widely available, and help others by contributing to medical research. For information about current studies, visit www.clinicaltrials.gov. For More Information For more information about insulin and devices for taking insulin, see the publication What I need to know about Diabetes Medicines, available by calling 1 800 860 8747 the FDA s information about insulin and insulin delivery devices at www.fda.gov/diabetes/insulin.html the American Diabetes Association s annual Resource Guide at www.diabetes.org/diabetes-forecast/resource-guide.jsp Acknowledgments Publications produced by the Clearinghouse are carefully reviewed by both NIDDK scientists and outside experts. This publication was reviewed by William V. Tamborlane, M.D., Yale University. This publication may contain information about medications. When prepared, this publication included the most current information available. For updates or for questions about any medications, contact the U.S. Food and Drug Administration toll-free at 1 888 INFO FDA (1 888 463 6332) or visit www.fda.gov. Consult your doctor for more information.

National Diabetes Education Program 1 Diabetes Way Bethesda, MD 20814 9692 Phone: 1 888 693 NDEP (1 888 693 6337) TTY: 1 866 569 1162 Fax: 703 738 4929 Email: ndep@mail.nih.gov Internet: www.ndep.nih.gov The National Diabetes Education Program is a federally funded program sponsored by the U.S. Department of Health and Human Services National Institutes of Health and the Centers for Disease Control and Prevention and includes over 200 partners at the federal, state, and local levels, working together to reduce the morbidity and mortality associated with diabetes. National Diabetes Information Clearinghouse 1 Information Way Bethesda, MD 20892 3560 Phone: 1 800 860 8747 TTY: 1 866 569 1162 Fax: 703 738 4929 Email: ndic@info.niddk.nih.gov Internet: www.diabetes.niddk.nih.gov The National Diabetes Information Clearinghouse (NDIC) is a service of the National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK). The NIDDK is part of the National Institutes of Health of the U.S. Department of Health and Human Services. Established in 1978, the Clearinghouse provides information about diabetes to people with diabetes and to their families, health care professionals, and the public. The NDIC answers inquiries, develops and distributes publications, and works closely with professional and patient organizations and Government agencies to coordinate resources about diabetes. NIH Publication No. 09 4643 May 2009