CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Similar documents
Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Call Medtronic at 1 (800) to verify the patient s current implanted system

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

Managing Metallic Artifacts in MRI

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

ENGINEERED TO ENABLE THE FUTURE OF CONNECTED HEALTH

FREQUENTLY ASKED QUESTIONS MONITORING

11 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

12 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

Model 5392 EPG Temporary Pacer

Advisa MRI and Ensura MRI SureScan pacing systems

MRI SureScan pacemakers & ICDs what you need to know

PACING AT THE BUNDLE OF HIS

CONSULTA CRT-P Model C4TR01

Pediatric pacemakers & ICDs:

HOW TO PERFORM HIS-BUNDLE PACING. Training Presentation

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Advanced ICD Concepts

Product Performance Report. Implantable devices. Pacing leads. Pacemakers. Defibrillators SNIA GROUP

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

Revo MRI Pacing System

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

Accessing Battery Information. Status symbol. Figure 1. Summary Dialog screen. Figure 2. Battery Status screen of a TELIGEN ICD 1

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

IMAGEREADY MR CONDITIONAL PACING SYSTEM

Industry-Tested. Stacks Up To the Competition 2

Percepta CRT-P MRI SureScan W1TR01

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

ICD: Basics, Programming and Trouble-shooting

2017 ACC/AHA/HRS SYNCOPE GUIDELINES

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

National Coverage Determination (NCD) for Cardiac Pacemakers (20.8)

AMPLIA MRI CRT-D SURESCAN DTMB1D4

UNLOCK THE ANSWER. The Reveal LINQ TM System lets your physician learn about your heart while you live your life.

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

Solara CRT-P MRI SureScan W1TR06

Tachycardia Devices Indications and Basic Trouble Shooting

IS THERE A LINK BETWEEN ATRIAL FIBRILLATION AND MY STROKE? Finding answers about cryptogenic stroke

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards

Preoperative Evaluation: Patients with Cardiac Disease

Advisa MRI SureScan. PACING SYSTEMs. References 1

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

CAPTIVATE SUMMARY CLINICAL SUMMARY. CAPTure Information Via Automatic Threshold Evaluation

WHY AM I FAINTING? Finding answers about unexplained fainting

Chapter 80 Implantable Cardiac Devices

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

Active Fixation Models: 7740, 7741 and 7742 Passive Fixation Models: 7731, 7732, 7735 and 7736

Perioperative Management of Cardiac Implantable Devices

POWERFUL CARDIAC MONITORING

WHAT CAN I DO ABOUT ATRIAL FIBRILLATION? Finding answers about atrial fibrillation

MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

John H. Ip, M.D FACC Associate Professor of Medicine Michigan State University Medical Director, EP Service

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

Check for the presence of blood or body fluids on the lead terminal/electrode tip and in header ports. Clean as necessary with sterile water.

A Closer Look. Connecting DF-4 and IS-4 Leads to DF-4 and IS-4 Defibrillators

ENABLE MRI CLINICAL STUDY SUMMARY

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

Azure XT DR MRI SureScan W2DR01

09/05/2018. True/False: All pacemakers have defibrillation capabilities.

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

CRF procedure PROCEDURE FLOW. PATIENT ASSESSMENT Symptoms and indication. Pacemaker & ICD registration. Procedures. Procedure ICD.

MRI GUIDELINES FOR INSPIRE THERAPY

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

Pacing Lead Implant Testing. Document Identifier

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

Implant Procedure Concepts

Inappropriate electrical shocks: Tackling the beast

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

12 th International Winter Arrhythmia School Collingwood, Ontario February 7, Dr. Derek Yung. MD, FRCPC

Cardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

Pacemaker System Malfunction Resulting from External Electrical Cardioversion: A Case Report

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Figure 2. Normal ECG tracing. Table 1.

Recurrent Implantable Defibrillator Discharges (ICD) Discharges ICD Storm

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

MEDICAL POLICY Cardioverter Defibrillators

Peri-operative management of pacemakers and implantable cardiac defibrillators

A SIMPLE SOLUTION FOR CARDIAC MONITORING

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

Need to Know: Implantable Devices. Carolyn Brown RN, MN, CCRN Education Coordinator Emory Healthcare Atlanta, Georgia

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

The Nuts and Bolts of ICD Therapy

Practice Questions.

BIVENTRICULAR PACEMAKER (CARDIAC RESYNCHRONIZATION THERAPY) FOR THE TREATMENT OF HEART FAILURE

Cardiac Pacemakers» 2013 HOSPITAL REIMBURSEMENT GUIDE

D044, D045, D046, D047, D174, D175, D176, D177 D020, D021, D022, D023 D150, D151, D152, D153 D010, D011, D012, D013 D140, D141, D142, D143

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

Supplemental Material

Transcription:

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART December 2015 This chart encompasses all Medtronic cardiac devices FDA-Approved as MR Conditional and included in the MRI SureScan portfolio. If a device and/or model number is not listed, then it is not approved for the MRI environment. Visit www.medtronic.com/mrc to search for a specific device or model number. THERAPY PRODUCT MODEL NUMBER MR CONDITIONAL MR MR SYSTEM SURESCAN LEADS RF COILS AVERAGE SAR GRADIENT SLEW RATE PER AXIS POSITIONING REQUIREMENTS PATIENT MONITORING OTHER CONDITIONS FOR USE PACEMAKERS Advisa MRI Revo MRI A2DR01 A3SR01 RVDR01 Yes If complete system is implanted with a SureScan pacemaker and SureScan lead(s) Horizontal bore magnet 1.5T only Pacing leads: 5086: 45, 52, 58 cm 5076: 35, 45, 52, 58, 65, 85 cm Integrated body coil Local receive coils extremities 200 T/m/s NA Maintain visual and verbal contact with the patient Monitor heart rate using pulse oximetry or ECG Advisa MRI and Revo MRI are approved for use with all SureScan leads. Please refer to device manuals for all conditions for use and cardiology training requirements. CARDIAC DEFIBRILLATORS Evera MRI S and XT DDMB1 D4, DVMB1 D4, DDMC3 D4, Yes If complete system is implanted with a SureScan ICD and SureScan lead(s) Horizontal bore magnet 1.5 T only Defibrillation leads: 6947M and 6935M Lengths 55, 62 cm See above for pacing leads. Integrated body coil Local receive coils extremities 200 T/m/s NA Maintain visual and verbal contact with the patient Monitor heart rate using pulse oximetry or ECG the entire time when SureScan is programmed to On Evera MRI is approved for use with all SureScan leads. Please refer to the device s MRI Technical Manual for all conditions for use and cardiology training requirements. CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATORS Amplia MRI Quad CRT-D Amplia MRI CRT-D Compia MRI Quad CRT-D Compia MRI CRT-D DTMB1QQ DTMB1D4 DTMC1QQ DTMC1D4 Yes If complete system is implanted with a SureScan CRT-D and SureScan lead(s) or the Model 6725 pin plug Horizontal bore magnet 1.5 T only CRT Leads: 4196, 4296, and 4396: Lengths: 78 and 88 cm 4298, 4398, and 4598: Lengths: 78 and 88 cm Integrated body coil Local receive coils extremities 200 T/m/s NA Maintain visual and verbal contact with the patient Monitor heart rate using pulse oximetry or ECG the entire time when SureScan is programmed to On All Amplia MRI and Compia MRI devices, including quadripolar and bipolar, are approved for use with all SureScan leads. Please refer to the device s MRI Technical Manual for all conditions for use and cardiology training requirements.

THERAPY PRODUCT MODEL NUMBER MR CONDITIONAL MR MR SYSTEM SURESCAN LEADS RF COILS AVERAGE SAR SLEW RATE POSITIONING REQUIREMENTS PATIENT MONITORING OTHER CONDITIONS FOR USE IMPLANTABLE CARDIAC MONITORS Reveal XT 9529 Yes Closed bore, Reveal DX 9528 Yes magnet 1.5 or 3.0T Reveal LINQ LNQ11 Yes Horizontal bore magnet 1.5 or 3.0T NA NA Surface receive-only coil (Do not use local, interventional, extremity volume, or surface transmit coil over or near the chest, trunk, or shoulder region) Receive-only coils extremities (Do not use local transmit coils on the chest, trunk, or shoulder region) Head SAR 4.0 W/kg 200 T/m/s 200 T/m/s Please refer to clinician manual Please refer to clinician manual Standard patient monitoring for MRI procedures Standard patient monitoring for MRI procedures 6-week post-implant delay. Please refer to clinician manual for all conditions for use. No post-implant delay. Please refer to clinician manual for all conditions for use. Brief Statement Advisa DR MRI and Advisa SR MRI SureScan Pacing Systems The Advisa DR MRI and Advisa SR MRI SureScan pacing systems are MR Conditional, and as such designed to allow patients to undergo MRI under the specified conditions for use. A complete SureScan pacing system, which consists of an approved combination (see http://www.mrisurescan.com/) MRI SureScan device with SureScan lead(s), is required for use in the MRI environment. Consult the device manuals to ensure all system components are MR Conditional. Indications The Advisa DR MRI SureScan Model A2DR01 and Advisa SR MRI SureScan Model A3SR01 IPGs are indicated for use as a system. A complete SureScan pacing system, including an Advisa DR MRI or Advisa SR MRI SureScan IPG and SureScan lead(s), are required for use in the MRI environment. The Advisa DR MRI and Advisa SR MRI SureScan systems are indicated for the following: Rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in activity Accepted patient conditions warranting chronic cardiac pacing include: Symptomatic paroxysmal or permanent second- or third-degree AV block Symptomatic bilateral bundle branch block Symptomatic paroxysmal or transient sinus node dysfunctions with or without associated AV conduction disorders Bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias The Advisa DR MRI device is also indicated for dual chamber and atrial tracking modes in patients who may benefit from maintenance of AV synchrony. Dual chamber modes are specifically indicated for treatment of conduction disorders that require restoration of both rate and AV synchrony, which include: Various degrees of AV block to maintain the atrial contribution to cardiac output VVI intolerance (for example, pacemaker syndrome) in the presence of persistent sinus rhythm Vasovagal syndromes or hypersensitive carotid sinus syndromes Antitachycardia pacing (ATP) is indicated for termination of atrial tachyarrhythmias in bradycardia patients with one or more of the above pacing indications The Advisa DR MRI and Advisa SR MRI SureScan systems are contraindicated for: Concomitant implantation with another bradycardia device Concomitant implantation with an implantable cardioverter defibrillator There are no known contraindications for the use of pacing as a therapeutic modality to control heart rate. The patient s age and medical condition, however, may dictate the particular pacing system, mode of operation, and implantprocedure used by the physician. Rate-responsive modes may be contraindicated in those patients who cannot tolerate pacing rates above the programmed Lower Rate Dual chamber sequential pacing is contraindicated in patients with chronic or persistent supraventricular tachycardias, including atrial fibrillation or flutter Asynchronous pacing is contraindicated in the presence (or likelihood) of competition between paced and intrinsic rhythms Single chamber atrial pacing is contraindicated in patients with an AV conduction disturbance ATP therapy is contraindicated in patients with an accessory antegrade pathway Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset, or device damage. Do not place transthoracic defibrillation paddles directly over the device. Use of the device should not change the application of established anticoagulation protocols. Patients and their implanted systems must be screened to meet the following requirements: no lead extenders, lead adaptors or abandoned leads no broken leads or leads with intermittent electrical contact as confirmed by lead impedance history a SureScan pacing system that has been implanted for a minimum of 6 weeks a SureScan pacing system implanted in the left or right pectoral region pace polarity parameters set to Bipolar for programming MRI SureScan to On pacing capture thresholds of 2.0 volts (V) at a pulse width of 0.4 milliseconds (ms) a lead impedance value of 200 ohms (Ω) and 1,500 Ω no diaphragmatic stimulation at a pacing output of 5.0 V and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when MRI SureScan is on Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate arrhythmia episodes, acceleration of tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Potential lead complications include, but are not limited to, valve damage, fibrillation, thrombosis, thrombotic and air embolism, cardiac perforation, heart wall rupture, cardiac tamponade, pericardial rub, infection, myocardial irritability, and pneumothorax. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation, or exit block. The SureScan system has been designed to minimize potential complications in the MRI environment. Potential MRI complications include, but are not limited to, lead electrode heating and tissue damage resulting in loss of sensing or capture or both, or induced currents on leads resulting in continuous capture, VT/VF, and/or hemodynamic collapse. See the device manuals before performing an MRI Scan for detailed information regarding the implant procedure, indications, MRI conditions of use, contraindications, warnings, precautions, and potential complications/adverse events. For further information, call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com. Caution: Federal law (USA) restricts these devices to sale by or on the order of a physician.

Reveal Insertable Cardiac Monitors and Patient Assistant 9538 Indications Reveal Insertable Cardiac Monitors The Reveal Insertable Cardiac Monitor Family are implantable patient-activated and automatically activated monitoring systems that record subcutaneous ECG and are indicated in the following cases: patients with clinical syndromes or situations at increased risk of cardiac arrhythmias patients who experience transient symptoms such as dizziness, palpitation, syncope, and chest pain, that may suggest a cardiac arrhythmia 9538 Reveal Patient Assistant The Reveal Patient Assistant is intended for unsupervised patient use away from a hospital or clinic. The Patient Assistant activates the data management feature in the Reveal Insertable Cardiac Monitor to initiate recording of cardiac event data in the implanted device memory. There are no known contraindications for the implant of Reveal Insertable Cardiac Monitors. However, the patient s particular medical condition may dictate whether or not a subcutaneous, chronically implanted device can be tolerated. Warnings/Precautions Reveal Insertable Cardiac Monitors Patients with a Reveal Insertable Cardiac Monitor should avoid sources of diathermy, high sources of radiation, electrosurgical cautery, external defibrillation, lithotripsy, therapeutic ultrasound, and radiofrequency ablation to avoid electrical reset of the device, and/or inappropriate sensing as described in the Medical procedure and EMI precautions manual. MRI scans should be performed only in a specified MR environment under specified conditions as described in the Reveal s Technical Manual. 9538 Reveal Patient Assistant Operation of the Model 9538 Patient Assistant near sources of electromagnetic interference, such as cellular phones, computer monitors, etc., may adversely affect the performance of this device. Potential complications include, but are not limited to, device rejection phenomena (including local tissue reaction), device migration, infection, and erosion through the skin. See the device manual for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/adverse events. For further information, please call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com. The Revo MRI SureScan pacing system is MR Conditional and as such is designed to allow patients to undergo MRI under the specified conditions for use. A complete SureScan pacing system, which consists of an approved combination (see http://www.mrisurescan.com/) MRI SureScan device with SureScan lead(s), is required for use in the MRI environment. Consult the device manuals to ensure all system components are MR Conditional. Indications The Revo MRI SureScan Model RVDR01 IPG is indicated for use as a system consisting of a Medtronic Revo MRI SureScan IPG implanted with two SureScan leads. A complete system is required for use in the MRI environment. The Revo MRI SureScan Model RVDR01 IPG is indicated for the following: Rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in activity Accepted patient conditions warranting chronic cardiac pacing include: Symptomatic paroxysmal or permanent second- or third-degree AV block Symptomatic bilateral bundle branch block Symptomatic paroxysmal or transient sinus node dysfunctions with or without associated AV conduction disorders Bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias The device is also indicated for dual chamber and atrial tracking modes in patients who may benefit from maintenance of AV synchrony. Dual chamber modes are specifically indicated for treatment of conduction disorders that require restoration of both rate and AV synchrony, which include: Various degrees of AV block to maintain the atrial contribution to cardiac output VVI intolerance (for example, pacemaker syndrome) in the presence of persistent sinus rhythm Antitachycardia pacing (ATP) is indicated for termination of atrial tachyarrhythmias in bradycardia patients with one or more of the above pacing indications. The device is contraindicated for: Implantation with unipolar pacing leads Concomitant implantation with another bradycardia device Concomitant implantation with an implantable cardioverter defibrillator There are no known contraindications for the use of pacing as a therapeutic modality to control heart rate. The patient s age and medical condition, however, may dictate the particular pacing system, mode of operation, and implantation procedure used by the physician. Rate responsive modes may be contraindicated in those patients who cannot tolerate pacing rates above the programmed Lower Rate Dual chamber sequential pacing is contraindicated in patients with chronic or persistent supraventricular tachycardias, including atrial fibrillation or flutter Single chamber atrial pacing is contraindicated in patients with an AV conduction disturbance ATP therapy is contraindicated in patients with an accessory antegrade pathway Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset, or device damage. Do not place transthoracic defibrillation paddles directly over the device. Use of the device should not change the application of established anticoagulation protocols. Patients and their implanted systems must be screened to meet the MRI Conditions of Use. Do not scan patients who do not have a complete Revo MRI SureScan pacing system consisting of a SureScan device and two SureScan leads; patients who have previously implanted devices, or broken, abandoned or intermittent leads; or patients who have a lead impedance value of < 200 Ω or > 1,500 Ω. Do not scan patients with a SureScan pacing system implanted in sites other than the left or right pectoral region. Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate arrhythmia episodes, acceleration of tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Potential lead complications include, but are not limited to, valve damage, fibrillation, thrombosis, thrombotic and air embolism, cardiac perforation, heart wall rupture, cardiac tamponade, pericardial rub, infection, myocardial irritability, and pneumothorax. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation, or exit block. The SureScan system has been designed to minimize potential complications in the MRI environment. Potential MRI complications include, but are not limited to, lead electrode heating and tissue damage resulting in loss of sensing or capture or both, or induced currents on leads resulting in continuous capture, VT/VF, and/or hemodynamic collapse.

Evera MRI System The Evera MRI SureScan defibrillation system is MR Conditional and, as such is designed to allow patients to be safely scanned by an MRI machine when used according to the specified MRI conditions for use. When programmed to On, the MRI SureScan feature allows the patient to be safely scanned while the device continues to provide appropriate pacing. Indications for Use The Evera MRI SureScan system is indicated to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. In addition, the dual chamber devices are indicated for use in the above patients with atrial tachyarrhythmias, or those patients who are at significant risk of developing atrial tachyarrhythmias. Notes: The ICD features of the device functions the same as other approved Medtronic market-released ICDs. The following notes are applicable based on the features available in the specific Evera MRI model. The use of the device has not been demonstrated to decrease the morbidity related to atrial tachyarrhythmias The effectiveness of high-frequency burst pacing (atrial 50 Hz Burst therapy) in terminating device classified atrial tachycardia (AT) was found to be 17%, and in terminating device classified atrial fibrillation (AF) was found to be 16.8%, in the VT/AT patient population studied The effectiveness of high-frequency burst pacing (atrial 50 Hz Burst therapy) in terminating device classified atrial tachycardia (AT) was found to be 11.7%, and in terminating device classified atrial fibrillation (AF) was found to be 18.2% in the AF-only patient population studied A complete SureScan defibrillation system is required for use in the MR environment, which is an Evera MRI SureScan ICD device with a SureScan defibrillation lead in the right ventricle and if using a dual chamber ICD, a SureScan atrial pacing lead. To verify that components are part of a SureScan system, visit http:// www.mrisurescan.com. Any other combination may result in a hazard to the patient during an MRI scan. The Evera MRI SureScan system is contraindicated for patients experiencing tachyarrhythmias with transient or reversible causes including, but not limited to, the following: acute myocardial infarction, drug intoxication, drowning, electric shock, electrolyte imbalance, hypoxia or sepsis. The device is contraindicated for patients who have a unipolar pacemaker implanted. The device is contraindicated for patients with incessant VT or VF. For dual chamber devices, the device is contraindicated for patients whose primary disorder is chronic atrial tachyarrhythmia with no concomitant VT or VF. For single chamber devices, the device is contraindicated for patients whose primary disorder is atrial tachyarrhythmia. Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset or device damage. Do not place transthoracic defibrillation paddles directly over the device. Patients and their implanted systems must be screened to meet the following requirements for MRI: no implanted lead extenders, lead adaptors, or abandoned leads; no broken leads or leads with intermittent electrical contact as confirmed by lead impedance history; a SureScan defibrillation system implanted in the left or right pectoral region; pacing capture thresholds of 2.0 V at a pulse width of 0.4 ms; no diaphragmatic stimulation at a pacing output of 5.0 V and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when MRI SureScan is programmed to On. Patients may be scanned using a horizontal field, bore, clinical 1.5T MRI system with operating frequency of 64 MHz, maximum spatial gradient 20 T/m, and maximum gradient slew rate performance per axis 200 T/m/s. Scanner must be operated in Operating Mode (whole body averaged specific absorption rate (SAR), head SAR ). Continuous patient monitoring is required while MRI SureScan is programmed to On. While MRI SureScan is programmed to On, arrhythmia detection and therapies are suspended, leaving the patient at risk of death from untreated spontaneous tachyarrhythmia. In addition, if the device is programmed to an asynchronous pacing mode, arrhythmia risk may be increased. Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate tachyarrhythmia episodes, acceleration of ventricular tachycardia and surgical complications such as hematoma, infection, inflammation and thrombosis. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation or exit block. The SureScan system has been designed to minimize potential complications in the MRI environment. Potential MRI complications include, but are not limited to, lead electrode heating and tissue damage resulting in loss of sensing or capture or both, or MR-induced stimulation on leads resulting in continuous capture, VT/VF and/or hemodynamic collapse. See the MRI SureScan Technical Manual before performing an MRI Scan and Device Manual for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/adverse events. For further information, please call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com or www.mrisurescan.com.

Amplia MRI /Amplia MRI Quad CRT-D SureScan Implantable Cardioverter Defibrillator with Cardiac Resynchronization System (CRT-D MRI System) The Amplia MRI CRT-D SureScan Model DTMB1D4 and Amplia MRI Quad CRT-D SureScan Model DTMB1QQ, hereafter referred to collectively as the Amplia MRI CRT-D device, is MR Conditional and, as such is designed to allow patients to be safely scanned by an MRI machine when used according to the specified MRI conditions for use. When programmed to On, the MRI SureScan feature allows the patient to be safely scanned while the device continues to provide appropriate pacing. Indications for Use The Amplia MRI CRT-D system is indicated for ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias, for use in patients with atrial tachyarrhythmias, or those patients who are at significant risk for developing atrial tachyarrhythmias and for providing cardiac resynchronization therapy in heart failure patients on stable, optimal heart failure medical therapy if indicated, and meet any of the following classifications: New York Heart Association (NYHA) Functional Class III or IV and who have a left ventricular ejection fraction 35% and a prolonged QRS duration. Left bundle branch block (LBBB) with a QRS duration 130 ms, left ventricular ejection fraction 30%, and NYHA Functional Class II. NYHA Functional Class I, II, or III and who have left ventricular ejection fraction 50% and atrioventricular block (AV block) that are expected to require a high percentage of ventricular pacing that cannot be managed with algorithms to minimize right ventricular pacing. Optimization of heart failure medical therapy that is limited due to AV block or the urgent need for pacing should be done post-implant. A complete SureScan defibrillation system is required for use in the MR environment. A complete SureScan CRT-D system includes the following components: The Amplia MRI CRT-D device A SureScan right atrial pacing lead or a Model 6725 pin plug for the right atrial port A SureScan left ventricular pacing lead A SureScan defibrillation lead To verify that components are part of a SureScan system, visit http://www.mrisurescan.com. Any other combination may result in a hazard to the patient during an MRI scan. Lead Integrity Alert The RV Lead Integrity Alert feature is intended primarily for patients who have a Medtronic ICD or CRT-D device and a Sprint Fidelis lead (Models 6949, 6948, 6931, and 6930), based on performance data. The RV LIA feature may not perform as well with a St. Jude Medical Riata /Durata lead or a Boston Scientific Endotak lead as it does when used with a Medtronic Sprint Fidelis lead. This is because different lead designs may have different failure signatures and conditions that may or may not be detected early by the RV LIA feature. The Amplia MRI CRT-D system is contraindicated for patients experiencing tachyarrhythmias with transient or reversible causes including, but not limited to, the following: acute myocardial infarction, drug intoxication, drowning, electric shock, electrolyte imbalance, hypoxia, or sepsis. The device is contraindicated for patients who have a unipolar pacemaker implanted. The device is contraindicated for patients with incessant VT or VF. The device is contraindicated for patients whose primary disorder is chronic atrial tachyarrhythmia with no concomitant VT or VF. Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset, or device damage. Do not place transthoracic defibrillation paddles directly over the device. Certain programming and device operations may not provide cardiac resynchronization. Patients and their implanted systems must be screened to meet the following requirements for MRI: no implanted lead extenders, lead adaptors, or abandoned leads; no broken leads or leads with intermittent electrical contact as confirmed by lead impedance history; a SureScan defibrillation system implanted in the left or right pectoral region; no diaphragmatic stimulation at a pacing output of 5.0 V and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when MRI SureScan is programmed to On. Additionally, for pacemaker-dependent patients, it is not recommended to perform an MRI scan if the right ventricular (RV) lead pacing capture threshold is greater than 2.0 V at 0.4 ms. A higher pacing capture threshold may indicate an issue with the implanted lead. Patients may be scanned using a horizontal field, bore, clinical 1.5T MRI system with operating frequency of 64MHz, maximum spatial gradient 20 T/m, and maximum gradient slew rate performance per axis 200 T/m/s. Scanner must be operated in Operating Mode (whole body averaged specific absorption rate (SAR), head SAR ). Continuous patient monitoring is required while MRI SureScan is programmed to On. While MRI SureScan is programmed to On, arrhythmia detection and therapies are suspended, leaving the patient at risk of death from untreated spontaneous tachyarrhythmia. In addition, if the device is programmed to an asynchronous pacing mode, arrhythmia risk may be increased. Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate tachyarrhythmia episodes, acceleration of ventricular tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation, or exit block. The SureScan system has been designed to minimize potential complications in the MRI environment. Potential MRI complications include, but are not limited to, lead electrode heating and tissue damage resulting in loss of sensing or capture or both, or MR-induced stimulation on leads resulting in continuous capture, VT/VF, and/or hemodynamic collapse. See the MRI SureScan Technical Manual before performing an MRI Scan and Device Manual for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/adverse events. For further information, please call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com or www.mrisurescan.com.

Compia MRI /Compia MRI Quad CRT-D SureScan Implantable Cardioverter Defibrillator with Cardiac Resynchronization System (CRT-D MRI System) The Compia MRI CRT-D SureScan Model DTMC1D4 and Compia MRI Quad CRT-D SureScan Model DTMC1QQ, hereafter referred to collectively as the Compia MRI CRT-D device, is MR Conditional and, as such is designed to allow patients to be safely scanned by an MRI machine when used according to the specified MRI conditions for use. When programmed to On, the MRI SureScan feature allows the patient to be safely scanned while the device continues to provide appropriate pacing. Indications for Use The Compia MRI CRT-D system is indicated for ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias and for providing cardiac resynchronization therapy in heart failure patients on stable, optimal heart failure medical therapy if indicated, and meet any of the following classifications: New York Heart Association (NYHA) Functional Class III or IV and who have a left ventricular ejection fraction 35% and a prolonged QRS duration. Left bundle branch block (LBBB) with a QRS duration 130 ms, left ventricular ejection fraction 30%, and NYHA Functional Class II. NYHA Functional Class I, II, or III and who have left ventricular ejection fraction 50% and atrioventricular block (AV block) that are expected to require a high percentage of ventricular pacing that cannot be managed with algorithms to minimize right ventricular pacing. Optimization of heart failure medical therapy that is limited due to AV block or the urgent need for pacing should be done post implant. A complete SureScan defibrillation system is required for use in the MR environment. A complete SureScan CRT-D system includes the following components: The Compia MRI CRT-D device A SureScan right atrial pacing lead or a Model 6725 pin plug for the right atrial port A SureScan left ventricular pacing lead A SureScan defibrillation lead To verify that components are part of a SureScan system, visit http://www.mrisurescan.com. Any other combination may result in a hazard to the patient during an MRI scan. Lead Integrity Alert The RV Lead Integrity Alert feature is intended primarily for patients who have a Medtronic ICD or CRT-D device and a Sprint Fidelis lead (Models 6949, 6948, 6931, and 6930, based on performance data. The RV LIA feature may not perform as well with a St. Jude Riata/Durata lead or a Boston Scientific Endotak lead as it does when used with a Medtronic Sprint Fidelis lead. This is because different lead designs may have different failure signatures and conditions that may or may not be detected early by the RV LIA feature. The Compia MRI CRT-D system is contraindicated for patients experiencing tachyarrhythmias with transient or reversible causes including, but not limited to, the following: acute myocardial infarction, drug intoxication, drowning, electric shock, electrolyte imbalance, hypoxia, or sepsis. The device is contraindicated for patients who have a unipolar pacemaker implanted. The device is contraindicated for patients with incessant VT or VF. The device is contraindicated for patients whose primary disorder is chronic atrial tachyarrhythmia with no concomitant VT or VF. Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset, or device damage. Do not place transthoracic defibrillation paddles directly over the device. Certain programming and device operations may not provide cardiac resynchronization. Patients and their implanted systems must be screened to meet the following requirements for MRI: no implanted lead extenders, lead adaptors, or abandoned leads; no broken leads or leads with intermittent electrical contact as confirmed by lead impedance history; a SureScan defibrillation system implanted in the left or right pectoral region; no diaphragmatic stimulation at a pacing output of 5.0 V and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when MRI SureScan is programmed to On. Additionally for pacemaker-dependent patients, it is not recommended to perform an MRI scan if the right ventricular (RV) lead pacing capture threshold is greater than 2.0 V at 0.4 ms. A higher pacing capture threshold may indicate an issue with the implanted lead. Patients may be scanned using a horizontal field, bore, clinical 1.5T MRI system with operating frequency of 64MHz, maximum spatial gradient 20 T/m, and maximum gradient slew rate performance per axis 200 T/m/s. Scanner must be operated in Operating Mode (whole body averaged specific absorption rate (SAR), head SAR ). Continuous patient monitoring is required while MRI SureScan is programmed to On. While MRI SureScan is programmed to On, arrhythmia detection and therapies are suspended, leaving the patient at risk of death from untreated spontaneous tachyarrhythmia. In addition, if the device is programmed to an asynchronous pacing mode, arrhythmia risk may be increased. Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate tachyarrhythmia episodes, acceleration of ventricular tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation, or exit block. The SureScan system has been designed to minimize potential complications in the MRI environment. Potential MRI complications include, but are not limited to, lead electrode heating and tissue damage resulting in loss of sensing or capture or both, or MR-induced stimulation on leads resulting in continuous capture, VT/VF, and/or hemodynamic collapse. See the MRI SureScan Technical Manual before performing an MRI Scan and Device Manual for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/adverse events. For further information, please call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com or www.mrisurescan.com. Medtronic 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879 medtronic.com Toll-free: 1 (800) 328-2518 (24-hour technical support for physicians and medical professionals) UC201204952j EN Medtronic 2015. Minneapolis, MN. All Rights Reserved. Printed in USA. 11/2015