Anatomical Considerations Regarding the Posterior Interosseous Nerve During Posterolateral Approaches to the Proximal Part of the Radius *

Similar documents
ANATOMICAL STUDY OF THE RADIAL TUNNEL BY CADAVERIC DISSECTION, FOR POSSIBLE SITES OF THE POSTERIOR INTEROSSEOUS NERVE ENTRAPMENT

Anatomic Landmarks for the Radial Tunnel

the shape, the size, the fit Ascension Modular Radial Head

Integra. Modular Radial Head System SURGICAL TECHNIQUE

Levels of the anatomical cuts of the upper extremity RADIUS AND ULNA right

Functional Anatomy of the Elbow

Coronal Shear Fractures of the Distal End of the Humerus*

Anterior Elbow Capsulodesis

Bipolar Radial Head System

Nearly all of these fractures are displaced, given the paucity of soft tissue attachments.

Risk of Axillary Nerve Injury in Standard Anterolateral Approach of Shoulder: Cadaveric Study

UDHT08.1.qxd:UDHT /03/08 17:14 Page 1. Surgical. Technique. Elbow Prosthesis. RHS Radial Head System.

The Elbow and the cubital fossa. Prof Oluwadiya Kehinde

Integra. Modular Radial Head System SURGICAL TECHNIQUE

Integra. Katalyst Bipolar Radial Head System SURGICAL TECHNIQUE

modular RADIAL HEAD E VOLVE

Competence of the Deltoid Ligament in Bimalleolar Ankle Fractures After Medial Malleolar Fixation *

The Biomechanics of the Human Upper Extremity-The Elbow Joint C. Mirzanli Istanbul Gelisim University

The Elbow 3/5/2015. The Elbow Scanning Sequence. * Anterior Joint (The anterior Pyramid ) * Lateral Epicondyle * Medial Epicondyle * Posterior Joint

MANAGEMENT OF INTRAARTICULAR FRACTURES OF ELBOW JOINT. By Dr B. Anudeep M. S. orthopaedics Final yr pg

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

Interesting Case Series. Posterior Interosseous Nerve Compression

Elbow Elbow Anatomy. Flexion extension. Pronation Supination. Anatomy. Anatomy. Romina Astifidis, MS., PT., CHT

Nerves of the upper limb Prof. Abdulameer Al-Nuaimi. E. mail:

Wright Medical Technology, Inc Cherry Road Memphis, TN

Rehabilitation after Total Elbow Arthroplasty

MUSCLES OF THE ELBOW REGION

Elbow Anatomy, Growth and Physical Exam. Donna M. Pacicca, MD Section of Sports Medicine Division of Orthopaedic Surgery Children s Mercy Hospital

Elbow dislocations represent 10% to 25% of all injuries. Elbow Fracture-Dislocations. The Role of Hinged External Fixation

The Elbow and Radioulnar Joints Kinesiology. Dr Cüneyt Mirzanli Istanbul Gelisim University

RADIOGRAPHY OF THE WRIST

Forearm and Wrist Regions Neumann Chapter 7

MEDIAL EPICONDYLE FRACTURES

MCQWeek2. All arise from the common flexor origin. The posterior aspect of the medial epicondyle is the common flexor origin.

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Ligaments of Elbow hinge: sagittal plane so need lateral and medial ligaments

Percutaneous Humeral Fracture Repair Surgical Technique

The Elbow Scanning Protocol

Chapter 6 The Elbow and Radioulnar Joints

region of the upper limb between the shoulder and the elbow Superiorly communicates with the axilla.

ARM Brachium Musculature

Proximal radioulnar translocation associated with elbow dislocation and radial neck fracture in child: a case report and review of literature

Locking Radial Head Plates

2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System.

KATALYST. Bipolar Radial Head System. Surgical Technique. orthopedics. KATALYST English. PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST and AFRICA ONLY

Terrible Triad: Tricks for Dealing with the Unstable Elbow

Lecture 9: Forearm bones and muscles

Anterior Displacement of Ulnar Nerve at the Elbow in Children Based on Ultrasonography

Recurrent subluxation or dislocation after surgical

Elbow. Chapter 2 LISTEN. Mechanism of Injury (If Applicable) Pain

divided by the bones ( redius and ulna ) and interosseous membrane into :

RADIOGRAPHY OF THE ELBOW & HUMERUS

RADIAL HEAD FRACTURES. It is far more common in adults than in children, (who more commonly fracture their neck of radius).

Elbow & Forearm H O W V I T A L I S T H E E L B O W T O O U R D A I L Y L I V E S?

LCP Distal Humerus Plates

the radial collateral ligament, the lateral ulnar collateral ligament, and the annular ligament 13

Pronator Teres Is an Appropriate Donor Muscle for Restoration of Wrist and Thumb Extension

Other Upper Extremity Trauma. Inje University Sanggye Paik Hospital Yong-Woon Shin

The Language of Anatomy. (Anatomical Terminology)

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4)

INTRODUCTION. Jianlin Shan 1 ; Chongwei Wang 1 ; Dajiang Ren 1 & Heng Jiang 2

Surgical Complications

Neurovascular Variations in Upper Limb

The Muscular System. Chapter 10 Part C. PowerPoint Lecture Slides prepared by Karen Dunbar Kareiva Ivy Tech Community College

Posteromedial approach to the distal humerus for fracture fixation

Pediatric Elbow Radiology. Seema Awatramani, MD Friday, April 5, 2018 ACOEP Spring Seminar

Monteggia Lesions In Children

Fractures and dislocations around elbow in adult

The posterior Monteggia lesion with associated ulnohumeral instability

Acu-Loc Wrist Plating System. Surgical Technique

Modular Ulnar Head surgical technique. Transforming Extremities

Lateral femoral traction pin entry: risk to the. femoral artery and other medial neurovascular structures

David G. Simpson, Ph.D.

1/19/2018. Winter injuries to the shoulder and elbow. Highgate Private Hospital (Whittington Health NHS Trust)

Elbow Hinge Fixator. Guided Flexion/Extension for Unstable Elbow Fractures.

PEDIATRIC UPPER EXTREMITY FRACTURE MANAGEMENT JULIA RAWLINGS, MD SPORTS MEDICINE SYMPOSIUM: THE PEDIATRIC ATHLETE 2 MARCH 2018

Hands PA; Obl. Lat.; Norgaard s Thumb AP; Lat. PA. PA; Lat.: Obls.; Elongated PA with ulnar deviation

Connects arm to thorax 3 joints. Glenohumeral joint Acromioclavicular joint Sternoclavicular joint

Case Presentation: Comminuted Fractures of the Proximal Ulna 11/28/2017. Disclosures. Surgical Strategy. Implant Choice. Melvin P.

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Nerve Injury. 1) Upper Lesions of the Brachial Plexus called Erb- Duchene Palsy or syndrome.

Hand and wrist emergencies

Chapter 6 part 2. Skeletal Muscles of the Body

Upper limb injuries in children. Key points, # & dislocations 7/23/2009 (MIMIC)

Interesting Case Series. Radial Tunnel Syndrome Complicated by Lateral Epicondylitis in a Middle-Aged Female

Elbow. Chapter 2 LISTEN. Mechanism of Injury (If Applicable) Pain

Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

Osteology of the Elbow and Forearm Complex. The ability to perform many activities of daily living (ADL) depends upon the elbow.

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

rhead System Radial Head Arthroplasty Operative technique

Biceps Brachii. Muscles of the Arm and Hand 4/4/2017 MR. S. KELLY

Predicting the Position of the Femoral Head Center

Lab Activity 11: Group II

Terrible triad of the elbow

Modified anconeus muscle transfer as treatment of failed surgical release of lateral epicondylitis of the elbow

Motion of Left Upper Extremity During A Right- Handed Golf Swing

Transcription:

Anatomical Considerations Regarding the Posterior Interosseous Nerve During Posterolateral Approaches to the Proximal Part of the Radius * BY THOMAS DILIBERTI, M.D., MICHAEL J. BOTTE, M.D., AND REID A. ABRAMS, M.D. Investigation performed at the Hand Surgery Service, Department of Orthopaedics, University of California, San Diego Abstract Background: The purpose of our study was to quantify the dimensions of a surgically safe zone along the proximal part of the radius, from the posterolateral aspect. Methods: The posterolateral approach between the anconeus and the extensor carpi ulnaris was performed in thirty-two cadaveric specimens, and the posterior interosseous nerve was exposed. Forearms were measured from the radial styloid process to the radiocapitellar joint. The distance from the capitellum to the point where the posterior interosseous nerve crossed the radial shaft and the angle between the nerve and the shaft were measured with forearms in pronation and supination. Results: Pronation of the forearm allowed safe exposure of at least the proximal thirty-eight millimeters of the lateral aspect of the radius, with an average proximal safe zone of 52.0 ± 7.8 millimeters. Supination decreased this proximal safe zone to as little as twentytwo millimeters and an average of 33.4 ± 5.7 millimeters. The angle formed by the posterior interosseous nerve and the radial shaft in supination averaged 47.4 ± 6.8 degrees; this decreased to 27.8 ± 6.7 degrees with pronation. Conclusions: Approaching the lateral aspect of the proximal part of the radius is safest in pronation. *No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. No funds were received in support of this study. 411 North Washington, Suite 7000, Dallas, Texas 75246. Scripps Clinic, 10666 North Torrey Pines Road, Mail Slot 116, La Jolla, California 92037. University of California, San Diego, 200 West Arbor Drive, Mail Code 8894, San Diego, California 92103. Copyright 2000 by The Journal of Bone and Joint Surgery, Incorporated The lateral 3, lateral J (Kocher J) 3, and posterolateral 3,5 approaches to the elbow are often used to expose the proximal part of the radius and the elbow joint in the management of fractures, arthritis, or contractures. While the surgical approaches and anatomy have been well described, and it is known that forearm pronation moves the posterior interosseous nerve distally along the posterolateral aspect of the radius, specific guidelines for safe exposure of the proximal portion of the radius have not been clearly delineated 1,2,4,6-13,16-19. The posterior interosseous nerve, known to be at risk during this exposure, crosses obliquely through the surgical field from proximal and anterior to distal and posterior. Surgeons have been advised to pronate the forearm to increase the safety of this exposure by allowing the posterior interosseous nerve to lie in a more anteromedial position 5,11,16,17. Previous studies have quantified the relationship of the posterior interosseous nerve to the proximal part of the radius from an anterior perspective 4,9,11-13. However, there is little data describing the position of the posterior interosseous nerve with respect to the proximal part of the radius and the elbow joint from a lateral perspective. The purpose of this study was to quantify the relationship of the posterior interosseous nerve to the head and proximal part of the shaft of the radius in order to establish a safe zone for the posterolateral approach to the elbow. Materials and Methods Thirty-two fresh cadaveric upper extremities from individuals who were an average of seventy-seven years old at the time of death were dissected. There were twelve right and twenty left upper extremities from fourteen men and eighteen women. All forearms could be passively rotated between 80 and 90 degrees of pronation and supination, and all had full flexion and extension of the elbow. A posterolateral approach to the proximal part of the radius and the elbow joint was performed through the interval between the extensor carpi ulnaris and anconeus muscles 3. In each limb, the posterior interosseous nerve was exposed proximally as it entered the supinator muscle and distally as it exited the supinator before arborizing into its terminal branches. The superficial layer of the supinator was incised over the posterior interosseous nerve, leaving the deep layer undisturbed. In each specimen, the distance from the most distal aspect of the capitellar surface to the point at which the posterior interosseous nerve crossed the midpoint of the width of the radius was measured with precision calipers (number 505-637; Mitutoyo, Tokyo, Japan). Measurements were to the nearest 0.001 inch (0.0254 millimeter) and were converted to millimeters. The angle formed by the posterior interosseous nerve and the longitudinal axis of the radius was measured with a handheld goniometer. Measurements were performed with the forearm in full supination and pronation (Figs. 1-A and 1-B). The first three specimens were studied with the elbow in 0, 45, and 90 degrees of flexion to determine if elbow position had any influence on the measurements. The remaining measurements were made with the elbow in 90 degrees of flexion, a typical position of the elbow during this surgical approach 5. To allow for the comparison of forearms of differing lengths, each radius was measured from the radiocapitellar joint to the tip of the ra- VOL. 82-A, NO. 6, JUNE 2000 809

810 T. DILIBERTI ET AL. TABLE I DATA ON THE THIRTY-TWO CADAVERIC SPECIMENS Average Standard Deviation Range Age (yrs.) 76.9 12.9 39-96 Male/female* 14/18 Right/left* 12/20 Supination Distance from capitellum to 33.4 5.7 22-47 posterior interosseous nerve (mm) Angle between posterior interosseous 47.4 6.8 32-69 nerve and radial shaft (degrees) Pronation Distance from capitellum to posterior 52.0 7.8 38-68 interosseous nerve (mm) Angle between posterior interosseous nerve and radial shaft (degrees) 27.8 6.7 18-50 *The values represent the numbers of cadavera rather than the average. dial styloid process so that safe zones could be expressed both as a Results percentage of the length of the radius and as an absolute distance. Averages and standard deviations were calculated with Microsoft Excel With the forearm in full supination, the posterior interosseous nerve crossed the midpoint of the long (version 7.0 [1983 to 1986]; Microsoft, Redmond, Washington). axis FIG. 1-A FIG. 1-B Photographs of a cadaveric specimen of a left arm, showing the posterior interosseous nerve (large arrowhead) with the forearm in full supination (Fig. 1-A) and full pronation (Fig. 1-B). The radiocapitellar joint (small arrowhead) is proximal and to the right. The top of each photograph is anterior. THE JOURNAL OF BONE AND JOINT SURGERY

ANATOMICAL CONSIDERATIONS REGARDING THE POSTERIOR INTEROSSEOUS NERVE 811 FIG. 2-A Drawing of a forearm in supination, demonstrating the effect on the position of the posterior interosseous nerve. The minimal distance from the radiocapitellar articulation (2.2 centimeters) is shown. FIG. 2-B Drawing of a forearm in pronation, demonstrating the effect on the position of the posterior interosseous nerve. The minimal distance from the radiocapitellar articulation (3.8 centimeters) is shown. of the radius at an average (and standard deviation) of 33.4 ± 5.7 millimeters (range, twenty-two to forty-seven millimeters) from the radiocapitellar articulation. With the forearm in full pronation, this distance increased to an average of 52.0 ± 7.8 millimeters (range, thirty-eight to sixty-eight millimeters). Flexion and extension of the elbow had no effect on these distances. The average radial length was 229.2 ± 14.7 millimeters (range, 208 to 259 millimeters). An average of 14.5 ± 2.0 percent (range, 10 to 19 percent) of the radius could be safely exposed proximally with the forearm in supination, and this average increased to 22.7 ± 3.0 percent (range, 17 to 27 percent) with the forearm in pronation. The angle formed by the posterior interosseous nerve and the long axis of the radius decreased from an average of 47.4 ± 6.8 degrees (range, 32 to 69 degrees) with the forearm in supination to 27.8 ± 6.7 degrees (range, 18 to 50 degrees) with the forearm in pronation (Table I). Thus, the posterior interosseous nerve becomes more parallel to the long axis of the radius with forearm pronation. VOL. 82-A, NO. 6, JUNE 2000

812 T. DILIBERTI ET AL. FIG. 3-A FIG. 3-B Lateral radiographs of a cadaveric left arm in supination (Fig. 3-A) and pronation (Fig. 3-B) with the course of the posterior interosseous nerve delineated with radiopaque markers. Discussion The posterior interosseous nerve moves medially as much as one centimeter with forearm pronation 8,15,16. This effect occurs in the coronal plane and is more useful when a surgeon is approaching the proximal part of the radius anteriorly. When a posterolateral approach to the elbow is performed, pronation of the forearm rotates the supinator and extensor muscles from a posterior to a relatively more anterior position, placing the posterior interosseous nerve more parallel to the radial shaft. By assuming this more parallel course, the posterior interosseous nerve is less likely to be injured during longitudinal sharp or blunt dissection (Figs. 2-A through 3-B). Exposure of the head, neck, and proximal part of the shaft of the radius is frequently necessary when fractures are treated with open reduction and internal fixation 14. The commonly used three-hole mini T-plate (Synthes, Paoli, Pennsylvania) is thirty-two millimeters in length. Proximal radial exposure with the forearm in pronation would have allowed safe placement of this device in all of the cadavera in the present study. However, forearm supination would have placed the posterior interosseous nerve at risk in most of our specimens. Osseous landmarks can be distorted when the radial head is fractured or dislocated. Since the posterolateral approach to the elbow is often used to treat these injuries, our measurements were based on the capitellar surface rather than on the radial head. Provided that the capitellum and the lateral column of the distal part of the humerus are intact, it is possible to accurately estimate the distance between the point at which the posterior interosseous nerve crosses the radial shaft and the most distal portion of the capitellum without relying on the radial head. It is our belief that the posterior interosseous nerve should be formally exposed and protected in any setting (trauma, posttraumatic reconstruction, tumor excision, and so on) in which the surgical dissection must be performed in proximity to the nerve as predicted by our measurements. The posterior interosseous nerve can be identified distally as it exits from beneath the supinator muscle, between its superficial and deep portions, and traced proximally back to the surgical zone to augment safety 10,11. The posterior interosseous nerve has been shown to enter and exit between the superficial and deep layers of the supinator at an average of 2.5 ± 0.3 centimeters and 6.0 ± 0.9 centimeters from the radiocapitellar joint, respectively 11. Our measurements should assist surgeons in operating more safely in the area of the proximal part of the radius, especially during complex trauma or revision surgery in which anatomical landmarks may not be as easily visualized. References 1. Capener, N.: The vulnerability of the posterior interosseous nerve of the forearm. A case report and an anatomical study. J. Bone and Joint Surg., 48-B(4): 770-773, 1966. 2. Carstam, N.: Operative treatment of fractures of the head and neck of the radius. Acta Orthop. Scandinavica, 19: 502-526, 1950. 3. Crenshaw, A. H.: Surgical techniques and approaches. In Campbell s Operative Orthopaedics, edited by S. T. Canale. Ed. 9, pp. 126-130. St. Louis, Mosby, 1998. 4. Fuss, F. K., and Wurzl, G. H.: Radial nerve entrapment at the elbow: surgical anatomy. J. Hand Surg., 16A: 742-747, 1991. 5. Hoppenfeld, S., and deboer, P.: Surgical Exposures in Orthopaedics: The Anatomic Approach. Ed. 2, pp. 103-106. Philadelphia, J. B. Lippincott, 1994. 6. Hotchkiss, R. N.: Displaced fractures of the radial head: internal fixation or excision? J. Am. Acad. Orthop. Surgeons, 5: 1-10, 1997. 7. Jupiter, J. B., and Mehne, D. K.: Trauma to the adult elbow and fractures of the distal humerus. In Skeletal Trauma. Fractures, Dislocations, Ligamentous Injuries, edited by B. D. Browner, J. B. Jupiter, A. M. Levine, and P. G. Trafton. Vol. 1, pp. 1125-1176. Philadelphia, W. B. Saunders, 1992. 8. Kaplan, E. B.: Surgical approach to the proximal end of the radius and its use in fractures of the head and neck of the radius. J. Bone and Joint Surg., 23: 86-92, 1941. THE JOURNAL OF BONE AND JOINT SURGERY

ANATOMICAL CONSIDERATIONS REGARDING THE POSTERIOR INTEROSSEOUS NERVE 813 9. Low, C. K.; Chew, J. T.; and Mitra, A. K.: A surgical approach to the posterior interosseous branch of the radial nerve through the brachioradialis a cadaveric study. Singapore Med. J., 35: 394-396, 1994. 10. Mayer, J. H., Jr., and Mayfield, F. H.: Surgery of the posterior interosseous branch of the radial nerve. Analysis of 58 cases. Surg., Gynec. and Obstet., 84: 979-982, 1947. 11. Mekhail, A. O.; Ebraheim, N. A.; Jackson, W. T.; and Yeasting, R. A.: Vulnerability of the posterior interosseous nerve during proximal radius exposures. Clin. Orthop., 315: 199-208, 1995. 12. Mekhail, A. O.; Ebraheim, N. A.; Jackson, W. T.; and Yeasting, R. A.: Anatomic considerations for the anterior exposure of the proximal portion of the radius. J. Hand Surg., 21A: 794-801, 1996. 13. Prasartritha, T.; Liupolvanish, P.; and Rojanakit, A.: A study of the posterior interosseous nerve (PIN) and the radial tunnel in 30 Thai cadavers. J. Hand Surg., 18A: 107-112, 1993. 14. Sanders, R. A., and French, H. G.: Open reduction and internal fixation of comminuted radial head fractures. Am. J. Sports Med., 14: 130-135, 1986. 15. Spinner, M.: Injuries to the Major Branches of Peripheral Nerves of the Forearm, pp. 28-32. Philadelphia, W. B. Saunders, 1972. 16. Strachan, J. C. H., and Ellis, B. W.: Vulnerability of the posterior interosseous nerve during radial head resection. J. Bone and Joint Surg., 53-B(2): 320-323, 1971. 17. Strauch, R. J.; Rosenwasser, M. P.; and Glazer, P. A.: Surgical exposure of the dorsal proximal third of the radius: how vulnerable is the posterior interosseous nerve? J. Shoulder and Elbow Surg., 5: 342-346, 1996. 18. Wadsworth, T. G.: The Elbow, pp. 24-27. New York, Churchill Livingstone, 1982. 19. Young, C.; Hudson, A.; and Richards, R.: Operative treatment of palsy of the posterior interosseous nerve of the forearm. J. Bone and Joint Surg., 72-A: 1215-1219, Sept. 1990. VOL. 82-A, NO. 6, JUNE 2000