Agilent Solutions for Lipidomics. Greater Insight into

Similar documents
Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Metabolomic and Proteomics Solutions for Integrated Biology. Christine Miller Omics Market Manager ASMS 2015

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Principles of Shotgun Lipidomics

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

The use of mass spectrometry in lipidomics. Outlines

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Mass Spectrometry based metabolomics

Glycerolipid Analysis. LC/MS/MS Analytical Services

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry

Phospholipid characterization by a TQ-MS data based identification scheme

AbsoluteIDQ p150 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

Thermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS

Automated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Lipid Class Separation Using UPC 2 /MS

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Mass-Spectrometric Analysis of Lipids (Lipidomics)

Agilent s LC/MS Portfolio and Applications Examples

Comprehensive Lipid Profiling of Human Liver Tissue Extracts of Non-Alcoholic Fatty Liver Disease

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

Annotation of potential isobaric and isomeric lipid species measured with the AbsoluteIDQ p180 Kit (and p150 Kit)

Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

Improving Coverage of the Plasma Lipidome Using Iterative MS/MS Data Acquisition Combined with Lipid Annotator Software and 6546 LC/Q-TOF

Achieve Broad Lipid Quantitation using a High-Throughput Targeted Lipidomics Method

New Instruments and Services

New Frontiers for MS in Metabolipidomics

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology

Comprehensive Food Profiling Combining High Resolution LC/MS and GC/MS Analyses

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

Join the mass movement towards mass spectrometry

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Choosing the metabolomics platform

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Agilent Lipidomics. Workflow Guide. MS Data Qualitative Workflow. With MS/MS ID Confirmation. Find features in one file by MFE in MH Qual.

Metabolomics: quantifying the phenotype

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

SimGlycan. A high-throughput glycan and glycopeptide data analysis tool for LC-, MALDI-, ESI- Mass Spectrometry workflows.

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions

CEU MASS MEDIATOR USER'S MANUAL Version 2.0, 31 st July 2017

Small Molecule Science: Experimental designs for achieving ultra trace analysis

The New 6495 Triple Quadrupole LC/MS

SimLipid 3.5. Manual PREMIER. Biosoft International Corina Way, Palo Alto, CA Tel: (650) FAX: (650)

High Throughput Workflow for Global Metabolomic Profiling of Biological Samples with RapidFire online SPE/MS system

AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification

SelexION Technology for Lipid Analysis: Pushing the Boundaries of Lipidomics

Lipid Analysis. Andréina Laffargue, IRD CRYMCEPT Montpellier workshop, October 17th Introduction to lipid structures

Welcome! Mass Spectrometry meets Cheminformatics WCMC Metabolomics Course 2014 Tobias Kind. Course: Search of MS/MS files with the NIST MS Search GUI

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Metabolite identification in metabolomics: Metlin Database and interpretation of MSMS spectra

Edgar Naegele. Abstract

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Metabolite identification in metabolomics: Database and interpretation of MSMS spectra

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Comparison of Relative Quantification of Monoclonal Antibody N-glycans Using Fluorescence and MS Detection

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Supporting Information

MASS SPECTROMETRY IN METABOLOMICS

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Life Science and Chemical Analysis Solutions. Baljit Ubhi, Jeff Patrick, David Alonso, and Joe Shambaugh 1 2 3

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Supplemental Information. LipiDex: An Integrated Software Package. for High-Confidence Lipid Identification

SCIEX Vitamin D 200M Assay for the Topaz System

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Essential Lipidomics Experiments using the LTQ Orbitrap Hybrid Mass Spectrometer

Non targeted Lipidomic Analysis by Direct Infusion Mass Spectrometry. Jianzhong Chen, PhD Assistant Professor School of Optometry UAB

Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

Practical application of UPLC MS/MS for targeted metabolite analysis

Agilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller

Determination of Amantadine Residues in Chicken by LCMS-8040

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

Accurate Quantification of Lipid Species by Electrospray Ionization Mass Spectrometry Meets a Key Challenge in Lipidomics

Go beyond. to realities unexplored. Comprehensive workflows, integrated solutions

Agilent Captiva Sample Preparation Filtration Portfolio GAUGE THE DIFFERENCE FILTRATION CAN MAKE

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

SYNAPT G2-S High Definition MS (HDMS) System

[application note] DIRECT TISSUE IMAGING AND CHARACTERIZATION OF PHOSPHOLIPIDS USING A MALDI SYNAPT HDMS SYSTEM

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Supporting information

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

MS/MS APPROACHES TO CLINICAL TESTING FOR INBORN ERRORS OF METABOLISM

Lipid Analysis ISOLATION, SEPARATION, IDENTIFICATION AND. Bridgwater, England LIPIDOMIC ANALYSIS. Fourth Edition. Invergowrie, Dundee, Scotland

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

1. Sample Introduction to MS Systems:

Transcription:

Agilent Solutions for Lipidomics Greater Insight into Lipid Metabolism

Understanding Lipidomics What is Lipidomics? The term "lipidome" refers to all the lipids that exist in an organism and their effects on diverse cellular processes. To understand the lipidome, it is important to characterize and quantify lipids, both collectively and individually. Mass spectrometry has emerged as a powerful analytical detection tool supporting effective lipid profiling for lipidomics research. HO Lipidomics Workflows The shotgun lipidomics workflow is a well-established infusion-based technique designed to rapidly yield quantitative lipid class data on a small number of lipids using class internal standards. This approach yields information on lipid class, composition, and R-groups, but does not provide unambiguous identification of the lipids. Shotgun lipidomics can be performed on either a triple quadrupole (QQQ) or quadrupole time-offlight (Q-TOF) mass spectrometer. Users can target specific lipid classes using precursor ion scan or neutral loss scan modes on QQQ mass spectrometers. A Q-TOF instrument offers higher sensitivity than a QQQ in scan modes and higher mass accuracy but lacks the specificity of the QQQ neutral loss scan. A significant limitation of shotgun lipidomics is ion suppression caused by the chemical diversity of the lipids and their very different ionization efficiencies. Without separation of the lipids, MS and MS/MS information alone cannot resolve biologically relevant differences in structure such as double bond location, R-group position, etc. The diverse chemical nature of lipid classes presents an ongoing challenge to the development of separation methodologies to resolve and identify individual lipids. Profiling lipidomics, a separation-based technique, has emerged as a more comprehensive approach, yielding relative quantitation and identification of hundreds of lipids in a single analysis. This development is made possible by advances in chromatography, as well as the development of ion mobility mass spectrometry (IMS) and advanced software analysis tools. 2

LIPIDOMICS TOOLS FOR A VARIETY OF APPLICATIONS Agilent is a leading provider of chromatography and mass spectrometry instruments, supplies, informatics, and technical support for global lipidomics research across multiple application areas. Basic and Clinical Research Study lipids in complex biofluids to identify lipid biomarkers and support understanding of cellular metabolism at a level of detail not attainable with classical analytical methods. Lipidomics can be used to document lipid profiles and reveal lipid alterations that occur in metabolic disorders, and is playing a pivotal role in understanding the mechanics of atherosclerosis, stroke, hypertension, and obesity. Agriculture Understand the roles of lipids in agriculture through their impact on soil and plant biology. Food and Nutrition Identify and evaluate how lipids, independently and together with proteins, regulate cellular and sub-cellular functions, including signaling and gene expression. Comprehensive lipidomics studies are unlocking new discoveries of the links between the food we eat and our health. Pharmaceutical Identify lipids to improve drug discovery and provide the foundation for more effective treatments for debilitating diseases. Biofuels Profile lipids in fatty acids and oil-producing microalgae as important markers for determining engine compatibility and performance metrics for biodiesels. Lipidomics is playing a role in engineering new strains to produce fatty acid ethyl esters (FAEEs), a component of biodiesel. Working with Agilent, we have co-developed enhanced workflows for the detection of low-abundance lipids using a combination of capture, separation, and nanofluidic chromatography followed by high-resolution tandem mass spectrometry. This approach has added critical detail to our understanding. Through our partnership with Agilent, we are also extending our research into areas related to lipidomics, including metabolomics, glycomics, and proteomics. Markus Wenk, Ph.D. National University of Singapore 3

The Lipidomics Separation Challenge Multiple Approaches, Multiple Solutions The structural diversity of lipids necessitates many separation approaches, with no single solution being suitable for all classes. Gas chromatography/mass spectrometry (GC/MS) has traditionally been used for fatty acyl characterization; this gives detailed R-group information but loses the lipid-level information due to the sample preparation (saponification). Terpenes and sterols are preferentially analyzed by GC/MS due to superior chromatographic separation and ionization. Both liquid chromatography (LC) and supercritical fluid chromatography (SFC) are very broadly applicable techniques that preserve the lipid-level information, require no derivatization, and interface easily to atmospheric pressure mass spectrometers. The choice of chromatographic method impacts the class of lipids resolved and detected, and therefore depends on the application. Lipid Category GC/MS LC/MS SFC/MS Fatty acids (acyls) Glycerolipids (triglycerides) Glycerophospholipids Sphingolipids Sterol lipids Prenol lipids Saccharolipids Terpenes (plants) Polyketides Table 1. Overview of the relative strength of the different chromatographic separations for various lipid classes. indicates the best separation technique for a given class. 4

Agilent supports a range of lipidomics solutions (Figure 1) with a unified data analytics platform across GC/MS, LC/MS, and SFC/MS. Data Acquisition Feature Finding Alignment and Statistical Analysis Identification Pathway Analysis MassHunter Software Mass Profiler Professional Software Qualitative Analytical Instruments Profinder Analysis and visualization ID Browser using Agilent METLIN Database and Agilent Fiehn Library Pathway Architect using public databases, such as KEGG Figure 1. Agilent lipidomics workflow solutions. 5

Powerful, Flexible, and Reliable Technology for Lipidomics The Chromatography of Lipids Normal phase and reversed-phase LC offer different benefits for lipid separation. Normal phase LC allows quick assessment of lipid classes (Figure 2), while reversedphase LC provides excellent retention time reproducibility and separation of lipids within a class (Figure 3). In comprehensive lipid analysis, normal phase LC is used for class-based fractionation, followed by reversed-phase LC of the fractions to resolve individual lipids. 5. 4. 3. 2. 1. Ceramides Sphingosines PE LPE PI PC SM LPC 1 5 1 15 2 25 3 35 Counts vs. Acquisition Time (min) Figure 2. Normal phase LC/MS separation of liver extract demonstrating separation by lipid class. PE = phosphatidylethanolamine; LPE = lysophosphatidylethanolamine; PI = phosphatidylinositol; PC = phosphatidylcholine; LPC = lysophosphatidylcholine. x1 6 9 8 7 6 5 4 3 2 1 Fatty Acids, Lyso-PLs Sphingosines Ceramides, SM, PLs DAGs 1 5 1 15 2 25 3 35 TAGs Counts vs. Acquisition Time (min) Figure 3. Reversed-phase LC/MS separation of liver extract demonstrating separation within lipid class. PL = phospholipid; SM = sphingomyelin; DAG = diacylglycerol; TAG = triacylglycerol. 6

Supercritical Fluid Chromatography (SFC) SFC uses very dense carbon dioxide as the main component in the SFC mobile phase. A form of normal phase chromatography, SFC is orthogonal to reversed-phase LC, providing high-resolution separation of polar and non-polar lipids in a single analysis. SFC is remarkably effective at resolving complex lipid mixtures (Figure 4). The Agilent 126 SFC system is designed to easily change between LC and SFC mode by means of a simple valve switch. x1 6 3 2 x1 6 x1 6 1.5 5 DGs Vit D precursors TGs 1 4 1 x1 6 1 2 Counts vs. Acquisition Time (min).5 1 1.4 Counts vs. Acquisition Time (min) 1.8 3 2 1 7 6 3 4 5 6 7 Counts vs. Acquisition Time (min) 5 4 3 2 1 1 2 3 4 5 6 7 Counts vs. Acquisition Time (min) Figure 4. SFC/MS analysis of fish oil from a commercial dietary supplement. Extracted ion chromatograms demonstrate the high resolving power SFC offers for the analysis of complex lipid mixtures. The Agilent 126 Infinity Analytical SFC/ UHPLC Hybrid System enables even greater versatility when a mass spectrometer (MS) is incorporated as an additional detector. The ability to rapidly switch back and forth between SFC/MS and HPLC/MS is a very powerful capability for lipidomics. The Agilent 126 SFC System Integrated Single software control of state-of-the-art SFC now on all Agilent LC/MS platforms Environmentally friendly Allows fast, high-resolution separation of compounds that cannot easily be separated by LC methods, with limited use of organic solvents Powerful Polar and non-polar lipids can be separated in a single run Versatile Delivers high flexibility with the greatest reliability 7

The Ion Mobility Advantage Ion mobility technology provides an additional, orthogonal dimension of separation for complex samples such as lipids. Following chromatographic separation, lipids are further resolved in the gas phase, providing separation based on the collision cross section of the lipid ion (Figure 5). Ion mobility can also provide lipid class separation for complex samples. The Agilent 656 IMS Q-TOF system (Figure 6) delivers accurate mass measurements combined with the highest resolution mobility separation commercially available. 7 6 Ion Mobility Drift Time (ms) 5 4 3 2 1 5 1 15 2 Mass (Da) Figure 5. IMS separation of an infused mixture of phosphatidylethanolamine (PE). The increase in drift time is associated with an increase in the number of carbon atoms. Ionization Source Front funnel Trapping gate Trapping funnel Drift tube Rear funnel Quad Mass Filter Collision Cell IBC Ion Pulser Figure 6. Each segment of the dynamic funnel assembly which includes a front funnel for sample enrichment, trapping ion funnel, drift tube and focusing rear funnel is carefully designed to maximize ion transmission from the source to the Q-TOF high-resolution mass analyzer. This enables resolution and characterization of complex samples using LC/IM/MS analysis while maintaining high sensitivity, providing a means to study the structural diversity of target molecules. 8

Lipid Identification LIPID Metabolites and Pathways Strategy (LIPID MAPS) is a consortium of laboratories created to develop the first internationally recognized lipid classification system, including lipid nomenclature and the structural representations necessary for identifying a large number of lipids. The LIPID MAPS classification system comprises eight lipid categories (Figure 7), with each category characterized by extensive structural and functional diversity, attributable to different aliphatic chains, stereoisomerism, chirality, and head group moieties. Complete lipid annotation and identification includes class, elemental composition, R-group size and location, number and location of double bonds, and double bond orientation (cis/trans). Sphingolipids Glycerophospholipids Polyketides Fatty Acyls Glycerolipids Acetyl CoA Saccharolipids Isopentenyl-PP Sterols Prenols Figure 7. The eight different lipid classes as defined by the LIPID MAPS consortium. Agilent offers different solutions for annotating or identifying lipids: database matching, MS/MS spectral library matching, or MS/MS theoretical spectral matching. Database matching can be performed using either the Agilent-METLIN database or SimLipid, a thirdparty software package from PREMIER BioSoft. MS/MS spectral library matching is performed only with the Agilent-METLIN MS/MS library, which is produced using chemical standards. SimLipid also supports MS/MS theoretical matching of lipid spectra. The Agilent-METLIN database and MS/MS library can be used for annotation and identification of lipids. It contains approximately 36,6 lipid entries from LIPID MAPS with approximately 64 of these having MS/MS spectra from standards. The SimLipid database includes eight lipid categories and 36,224 lipid entries. 9

Software Designed for Flexibility In lipid profiling, multiple samples are analyzed with the intent to compare and discover lipid differences between sample groups. Agilent offers MassHunter Profinder software for lipid feature extraction and alignment across samples. The MS-only results can be exported to either SimLipid for identification or Mass Profiler Professional (MPP) for statistical analysis. If SimLipid is not used for identification, lipids can be identified in MPP using the built-in ID Browser and the Agilent-METLIN database for accurate mass matching. Depending on the data analysis approach, various workflows can be employed, using a combination of Agilent software solutions (Figure 8). If MS/MS data was acquired, analysis can be performed using MassHunter Qualitative Analysis software, with identification through either SimLipid or the Agilent METLIN Metabolite Personal Compound Database and Library (PCDL)(Figure 9). MS-only MS-only MS-only MS or MS/MS MH Profinder MH Profinder MH Qual MH Qual Aligned Aligned SimLipid ~ ~ SimLipid3 MPP MPP SimLipid ~ ~ SimLipid3 Figure 8. Lipidomics workflow integrated into MassHunter software. Annotated Aligned Aligned and Annotated SimLipid ~ ~ SimLipid3 MPP ID Browser MPP SimLipid is available from PREMIER Biosoft International through their website www.premierbiosoft.com/lipid/ index.html. Experimental MS/MS Spectrum Difference Spectrum METLIN PCDL Spectrum Figure 9. Results of MS/MS library searching of a human serum sample in MassHunter Qualitative Analysis against the METLIN Metabolite PCDL. The top spectrum is the MS/MS collected on an Agilent Q-TOF for one of the compounds; the bottom is the library spectrum from METLIN. The middle shows the difference spectrum. The score in the Compound List (92.6) indicates a high-quality hit. 1

Pathway Architect Reveals Important Biological Context Analysis of lipid samples by LC/MS presents special challenges due to the choice of appropriate chromatography, as well as annotation and identification of compounds found. Untargeted profiling approaches will likely provide a large number of candidate lipids without a biological context. MPP s Pathway Architect module searches, filters, maps, and visualizes data onto biological pathways. Two types of pathway analyses are supported; one is a Literature Derived Network analysis based on natural language processing of published literature, while the other is designed to analyze publicly available curated biological pathways, such as KEGG, BioCyc, and Wikipathways. The experimental data is projected onto these pathways and allows users to interactively filter, zoom, or select data. Pathways can be selected and a list of lipids, proteins, metabolites, transcripts, and genes can be exported and used by other programs to create new pathway-directed experiments. In this example (Figure 1), a lipid analysis workflow begins with untargeted profiling of a sample by MS and MS/MS to find as many lipid compounds as possible. SimLipid identification software is used to annotate the results, which are then visualized in Pathway Architect on a KEGG pathway. Figure 1. Results of a pathway analysis of a human serum sample in Pathway Architect using the KEGG pathway database. Three lipid compounds were identified using SimLipid and found to be present in the sphingolipid metabolism pathway. Compounds are highlighted as yellow dots on the pathway; the currently selected compound (sphingosine) is outlined in green. 11

Automation FOR Lipidomics Automating Sample Prep for Improved Results Comparison of steps in manual versus semi-automated protocol Automated protocols for lipidomics sample preparation increase reproducibility and decrease the time spent preparing samples for analysis. In addition, automation frees valuable personnel for more complex tasks and minimizes the impact of staff turnover, which is especially important in long-term studies. For example, a semi-automated extraction method for phospholipids and sphingolipids from human plasma was developed using the Agilent Bravo Automated Liquid Handling Platform in the lab of Dr. Markus Wenk at SLING, the lipidomics incubator at the National University of Singapore. Manual Extraction Samples aliquoted manually from original tube into smaller fractions Extraction solvent added by manual transfer Sonication and centrifugation Semi-automated Extraction Samples automatically aliquoted from original tubes into smaller fractions Extraction solvent added by automated transfer Sonication and centrifugation (Manual tansfer to equipment) Supernatants manually transferred to vials for MS analysis Supernatants automatically transferred to 96 well plates for MS analysis Figure 11: In the Wenk lab, an automated method using the Bravo Liquid Handling Platform replaces three of the four steps in preparing phospholipid and sphingolipid samples. 12

Agilent s automated liquid handling solutions increase throughput without compromising data quality by simplifying error-prone tasks such as liquid handling, labeling and sealing. Bravo Extraction nmol/ml of plasma 14 y =.976x +.3895 12 R 2 =.9964 1 8 6 4 2 5 1 15 Manual Extraction nmol/ml of Plasma Lipid standard % RSD Semi-automated % RSD Manual PE 14:/14: 4.8 7.13 PC 14:/14: 5.85 5.72 C17 Ceramide 7.32 11.97 LysoPC 2: 5.27 5.5 SM 3:1 3.79 4.96 GluCer d18:1/8: 6.81 6.34 Figure 12. The regression plot shows equivalent quantitation results for the semi-automated preparation method on the Bravo Liquid Handling Platform compared to the manual method. In the table to the right, you can see that the semi-automated method is better at quantifying the standard lipids. 13

Agilent GC/MS and LC/MS Solutions for Lipidomics GC/MS Instruments 5977A Series GC/MSD System Ideal for routine targeted and discovery analysis. The Agilent 5977A GC/MSD provides reliability and ease of use for screening large numbers of samples. 7C and 71 Triple Quadrupole GC/MS Systems For more demanding target analyses, achieve the best MS/MS quantification and the lowest detection limits with the 71. 72B GC/MS Q-TOF System Identify for previously unknown lipids with high-resolution MS/MS data. The Agilent 72B GC/MS Q-TOF complements the separation power of the 789B GC with continuous high-resolution data. Agilent has a full family of GC and LC columns and supplies, for all the instruments in your lab, to support lipidomics research. Easily find the best set of solutions for your lab at www.agilent.com/chem/selectiontools 14

LC/MS Instruments 126 Infinity Analytical SFC Systems The Agilent 126 SFC/MS allows fast, highresolution separations of lipids that cannot easily be separated by other methods. Polar and nonpolar lipids can be separated in a single run, with high flexibility, high precision, and excellent reliability. 65 Series Accurate-Mass Q-TOF Ideal for profiling and identifying low molecular-weight compounds, the 65 Series Q-TOF provides MS/MS functionality. The typical mass accuracy increases confidence in lipid identification and reduces false positives in database searches. 129 Infinity II LC Achieves unmatched separation and detection performance, delivering data of the highest quality for ultimate confidence. Unmatched sample capacity and injection cycle speed combine with new levels of usability for highest throughput. 64 Series Triple Quadrupole LC/MS With extremely fast MRM transitions and robust and reliable performance, the 64 Series Triple Quadrupole LC/MS enables maximum uptime to analyze large sample sets. Sub-femtogram-level sensitivity enables detection of low-abundance lipids. Bravo Automated Liquid Handling Platform For lipid sample preparation, the Bravo platform is capable of transferring samples from collection tubes to wellplate format, performing liquid additions and sample extraction. 15

For more information, download the Lipidomics Workflow Overview and guide showing instructions for lipidomics analyses using MassHunter Qualitative Analysis, Profinder, SimLipid, and MPP software. These guides provide step-by-step details for lipidomics workflows. Find them by searching for 5991-1643eN and 5991-1644eN, available at www.agilent.com/chem/library. Learn more www.agilent.com/chem/lipidomics Find an Agilent customer center www.agilent.com/chem/contactus USA and Canada 1-8-227-977 agilent_inquiries@agilent.com europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc. 215 Published in the USA, May 11, 215 5991-5419EN