GSI AMTAS AUTOMATED AUDIOMETRY. Setting The Clinical Standard

Similar documents
GRASON-STADLER HEARING ASSESSMENT SYSTEMS

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

GSI-AMTAS. Setting The Clinical Standard. Part NumberD Rev. B

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

AD629 The true hybrid

GSI AMTAS FLEX USER MANUAL. Setting The Clinical Standard. Part Number D Rev. E

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

AC40. The true clinical. hybrid

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

VALIDITY OF DIAGNOSTIC COMPUTER-BASED AIR AND FOREHEAD BONE CONDUCTION AUDIOMETRY

AUDIOMETERS AUDIXI 10

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

myaudiometer. It s familiar, and it s so much

Unlock. your potential. Otometrics Madsen A450 the audiometer that works for you N O A H P M M R E P O R T I N G H I T C O U N S E L I N G

TOWN OF FAIRFIELD PUBLIC HEALTH NURSING. MANUAL: School Health APPROVED BY: Board of Health School Medical Advisor

Oscilla - excellence since 1960

What Is the Difference between db HL and db SPL?

A FRESH Approach to Pediatric Behavioral Testing

Basic Audiogram Interpretation

Hearing Conservation Services Specifications

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

Introduction to Audiology: Global Edition

HEARING CONSERVATION CHECKLIST

Audiogram+: GN Resound proprietary fitting rule

AMBCO AUDIOMETER

USERS GROUP AGENDA 2014

Eliminate the Most Common Challenges in Audiometric Testing A Case for Tablet Audiometry in Occupational Hearing Conservation

EVALUATION OF SPEECH PERCEPTION IN PATIENTS WITH SKI SLOPE HEARING LOSS USING ARABIC CONSTANT SPEECH DISCRIMINATION LISTS

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

Errol Davis Director of Research and Development Sound Linked Data Inc. Erik Arisholm Lead Engineer Sound Linked Data Inc.

Utility of Standard DPOAEs in the Evaluation of the Normal-Hearing Tinnitus Patient

Clinical evaluation of a computerized self-administered hearing test

ORIGINAL ARTICLE. Chung-Yi Lee, 1,2 Fu-Shan Jaw, 1 Shin-Liang Pan, 3,4 Tai-Hsin Hsieh, 2 Chuan-Jen Hsu 2 *

Supplementary Online Content

(b) is as low as is reasonably practicable, where it is not reasonably practicable to meet the standard under clause (a).

REFERRAL AND DIAGNOSTIC EVALUATION OF HEARING ACUITY. Better Hearing Philippines Inc.

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

Clinical Validation of the AMTAS Automated Audiometer Robert H Eikelboom 1,2,3, De Wet Swanepoel 1,2,3, Shahpar Motakef 1,2,4, Gemma S Upson 1,2

Clinical Validation of the AMTAS Automated Audiometer Robert H Eikelboom 1,2,3, De Wet Swanepoel 1,2,3, Shahpar Motakef 1,2,4, Gemma S Upson 1,2

Price list. Master Products

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017

Verification of soft speech amplification in hearing aid fitting: A comparison of methods

Basic Principles. The Current State of Auditory Steady-State Responses

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

Speech Recognition in Noise for Hearing- Impaired Subjects : Effects of an Adaptive Filter Hearing Aid

Bone conduction hearing solutions from Sophono

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

Hearing Conservation Program

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

False 4-kHz Air-Bone Gaps


Organisation Internationale de Métrologie Légale

Hearing Loss: From Audiogram to RFC Learn How to Effectively Represent Deaf and Hard of Hearing Claimants

User Manual. - Pro Edition -

L G Davison*, BSc C Barlow, PhD, MIOA M Ashmore, RHAD, MIOA R Weinstein, RHAD Southampton Solent University Faculty of Maritime and Technology

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

SECTION 6: DIAGNOSTIC CLASSIFICATION TERMS AND NORMATIVE DATA

A good audiologic diagnosis is increasingly more important

Prior authorization is required for all hearing aids.

Contents. Exercises and Questions. Answers

marketplace A special section featuring some of the hottest available products and services in the industry. Blueprint Solutions

Practical Grading System for Evaluating Cisplatin Ototoxicity in Children

SOFTWARE INSTRUCTION MANUAL

A three-frequency audiogram for use in industry

Audiometric Techniques Program in Audiology and Communication Sciences Pediatric Audiology Specialization

MEASUREMENTS AND EQUIPMENT FOR AUDIOLOGICAL EVALUATIONS

Hearing Protection for the Workplace

ABSTRACT INTRODUCTION

AD226 Diagnostic Audiometer

TAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM

Challenges in Fitting a Hearing Aid to a Severely Collapsed Ear Canal and Mixed Hearing Loss DOI: /jaaa

User Manual. - Pro Edition -

Welcome to Your Audiogram

General about Calibration and Service on Audiometers and Impedance Instruments

MA 25 Operating Manual

NEW YORK STATE MEDICAID PROGRAM HEARING AID PRIOR APPROVAL GUIDELINES

Rand Dollar Pound Aus Dollar Euro NZD KUDUwave Prime R54, $4, , $5, , $5,922.00

Effect of auditory processing on the preference of monaural amplification for adults with symmetrical hearing loss

Thresholds of Tone Burst Auditory Brainstem Responses for Infants and Young Children with Normal Hearing in Taiwan

It a graph that represents the hearing thresholds across frequencies.

Auditory model for the speech audiogram from audibility to intelligibility for words (work in progress)

Sandra Gordon-Salant Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742

DSL v5 in Connexx 7 Mikael Menard, Ph.D., Philippe Lantin Sivantos, 2015.

A Mixed-Methods Assessment of Hearing Conservation Program Effectiveness

General Catalogue. Hearing Screening & Diagnostics

Handheld OAE-Tympanometry Combination System

Mistakes on Real Ear Measures Clinicians Often Make. Michael Valente

Hearing Conservation Program Evaluation Checklist

Audiology Services. Table of Contents. Audiology Services Guidelines : Hearing services

Optimal Design: Bekesy Test for Mobile

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

UC Merced Hearing Conservation Program

UNM SRMC AUDIOLOGY PRIVILEGES

ISO INTERNATIONAL STANDARD

Transcription:

GSI AMTAS AUTOMATED AUDIOMETRY Setting The Clinical Standard

GSI AMTAS, or Automated Method for Testing Auditory Sensitivity, is a patient-directed evaluation tool that uses patented test methods and accuracy algorithms to perform diagnostic or screening audiometry. With over 10 years of research and development, the validity of AMTAS has been proven through comprehensive studies. Focus on Patient Care AMTAS was created as a resource for clinicians to help manage their busy schedules and promote an efficient office environment. Most importantly, AMTAS frees up the clinician, allowing them to spend more time focused on patient care. AMTAS is available in two versions, AMTAS Pro and AMTAS Flex, which give the hearing professional options to best fit clinical needs.

AMTAS Pro AMTAS Pro connects to a GSI audiometer, the AudioStar Pro or Pello. This version offers diagnostic and screening testing for air and bone conduction with masking and speech SRT, WRS with masking. This test typically takes 15-20 minutes to complete and provides nine quality indicators and two reporting options for interpretation. AMTAS Flex AMTAS Flex is a stand-alone test that uses a tablet with no audiometer required. This version offers screening and threshold air conduction audiometry. The screening test typically takes 1-2 minutes to complete. The threshold test provides up to six quality indicators and two reporting options: interpret and counseling. Threshold testing takes 10-15 minutes to complete.

AMTAS Frees Up More Time For Walk-ins In a practice that continues to get busier, AMTAS allows clinicians to have one patient working through an audiogram, while attending to walk-ins and other patients that may otherwise may have long waiting times. Clean and Checks When a patient returns for their annual evaluation, the clinician can start the patient on AMTAS while a clean and check of hearing aids is completed. Counseling One patient can work on AMTAS while the clinician meets with another patient for counseling on test results, hearing aid adjustments, or answering questions.

Validation in Testing With numerous comprehensive studies backed by years of research and development, AMTAS is different from other automated audiometric tests. AMTAS provides nine quality indicators, classification of audiometric findings and two report formats. Quality Indicators The quality indicators provide information about the patient's behavior during testing. Using the quality indicators gives the clinician insight on how to proceed with counseling and further testing. 9 Quality Indicators Classification of Audiometric Findings Once the data is obtained, AMTAS uses a patented method, AMCLASS, to classify the audiogram based upon the configuration, severity, and site of lesion. RELIABILITY SITE OF LESION SEVERITY ASYMMETRY Reporting AMTAS generates two reporting options. The Audiologist Report captures the quality indicators, classification, and audiometric data for a detailed look at the test results. The Patient Report is a comprehensive and easy-to-understand interpretation of the audiometric findings. Audiologist Report Patient Report

GSI AMTAS AUTOMATED AUDIOMETRY Technical Specifications Air Conduction Diagnostic Frequencies: 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz Bone Conduction Diagnostic Frequencies: 500, 1000, 2000, 4000 Hz Air Diagnostic Level Range: -20 to 100 db HL Bone Diagnostic Level Range: -20 to 75 db HL (frequency dependent) Masking: Narrow band noise, speech noise Air Conduction Screening Frequencies: 500, 1000, 2000, 4000 Hz Air Conduction Screening Level: 20 or 25 db HL Speech Testing: Speech Recognition Threshold (SRT), Word Recognition Score (WRS) AMTAS Flex AMTAS Pro Air Conduction Diagnostic 4 4 Air Conduction Screening 4 4 Masking 4 4 Bone Conduction Diagnostic 4 Speech SRT 4 Speech WRS 4 Connect to Audiometer 4 VA Quasar Integration 4 db HL Range 10 to 80-20 to 100 Quality Indicators 4 4 Audiogram Classification Limited Comprehensive Device Screen Size 10-12 inch 22 inch????????????? Rev A Setting The Clinical Standard www.grason-stadler.com Grason-Stadler, 10395 West 70th Street, Eden Prairie, Minnesota 55344 800-700-2282 952-278-4402 fax 952-278-4401 e-mail info@grason-stadler.com