FOR many decades, cardiovascular disease has been one of

Similar documents
Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with Stenosis

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm

NUMERICAL STUDY OF PULSATILE BLOOD FLOW IN THE CORONARY SYSTEM WITH THE RCA BYPASS GRAFT

Arteriovenous Graft Modeling and Hemodynamic Interpretation

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries

Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

EFFECT OF BRANCHINGS ON BLOOD FLOW IN THE SYSTEM OF HUMAN CORONARY ARTERIES. Benchawan Wiwatanapataphee. Yong Hong Wu. Thanongchai Siriapisith

Blood flow in vessels with artificial or pathological geometrical changes

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1

Blood Flow Simulation toward Actual Application at Hospital

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY

Analysis of the effects of plaque deposits on the blood flow through human artery

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture

Mathematical and Computational study of blood flow through diseased artery

A Review of Study of the Effects of Plaque Deposits on the Blood Flow through Human Artery

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

Simulations of the blood flow in the arterio-venous fistula for haemodialysis

A computational fluid dynamics simulation study of coronary blood flow affected by graft placement

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries

A Review: Hemodynamics of Cerebral Aneurysm with Mathematical Modeling

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study

Asymmetric flows of non-newtonian fluids in symmetric stenosed artery

Assessment of the Effects of Increasing Levels of Physiological Realism in the Computational Fluid Dynamics Analyses of Implanted Coronary Stents

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION

Post-conditioning. P a g e 1. To my Thesis Committee,

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis

Blood flow in S-shaped in-plane and out-of-plane coronary arteries

A Two-layered Model for the Analysis of Arterial Rheology

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics

Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel

A Computational Fluid Dynamics Study on Bidirectional Glenn Shunt Flow with an Additional Pulsatile Flow Through a modified Blalock-Taussig Shunt

NUMERICAL SIMULATION OF EFFECTS OF REYNOLDS NUMBER ON NON-NEWTONIAN BLOOD FLOW WITH SPIRAL COMPONENT THROUGH A REGULAR STENOSED ARTERY

Comparison of Stent Designs using Computational Fluid Dynamics

Physiological flow analysis in significant human coronary artery stenoses

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

Calculation of the Wall Shear Stress in the case of an Internal Carotid Artery with stenoses of different sizes

Simulation of Blood Flow Coronary Artery with Consecutive Stenosis and Coronary-Coronary Bypass

FSI Analysis of Diseased Coronary using Patient Specific Data

STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION

Experimental Flow Studies on Carotid Artery Models with and without Stents

Simulation of blood flow through endovascular prosthesis in patients with Abdominal Aortic Aneurysm

Non-Newtonian blood flow in human right coronary arteries: Transient simulations

The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries

Vascular reconstruction: CFD predictions of bypass graft haemodynamics

Saccular Aneurysm Formation in Curved and Bifurcating Arteries

Numerical analysis of blood flow in human abdominal aorta

Microrheology P38. Laminar blood flow in stenotic microchannels

Flow Analysis with Stent Placement in the Cerebral Aneurysm

Simulation of Physiological Non-Newtonian Blood Flow through 3-D Geometry of Carotid Artery with Stenosis

Flow in re-stenosed artery after angioplasty

Estimation and Comparison of T Graft Versus Conventional Graft for Coronary Arteries

FFR CT : Beyond FFR. Bon-Kwon Koo, MD, PhD. Seoul National University Hospital, Seoul, Korea. Seoul National University Hospital Cardiovascular Center

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

4D model of hemodynamics in the abdominal aorta

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta

Computational Fluid Dynamics Analysis of Blalock-Taussig Shunt

BLOOD SIMULATION AND VIRTUAL BYPASS SURGERY

A Mathematical Model for Flow and Diffusion through Stenotic Capillary-Tissue Exchange System

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

Keywords: Angioplasty, Explicit finite elements method, Tube hidroforming, Stents.

A numerical study on the effect of hematocrit on hemodynamic characteristics in arteriovenous graft

BLOOD FLOW VISUALISATION THROUGH CAROTID BIFURCATION USING ANSYS CFD

Medical device design using Computational Fluid Dynamics (CFD)

Correlations of coronary plaque wall thickness with wall pressure and wall pressure gradient: A representative case study

Computational design of Intracranial Stent using 3D visualization system

Developing Pulsatile Flow in a Deployed Coronary Stent

Original. Stresses and Strains Distributions in Three-Dimension Three-Layer Abdominal Aortic Wall Based on in vivo Ultrasound Imaging

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

Numerical Study on Effects of Drug-coating Position of Drug-eluting Stents on Drug Concentration

Mathematical modeling of atherosclerotic plaque formation coupled with a non-newtonian model of blood ow

Physiological Flow Simulation in Residual Human Stenoses After Coronary Angioplasty

Three Dimensional Large Eddy Simulation of Blood Flow and Deformation in an Elastic Constricted Artery

ANALYSIS OF FLUID-STRUCTURE INTERACTION IN ABDOMINAL AORTIC ANEURYSM WITH HIGH AND NORMAL BLOOD PRESSURE

CPM Specifications Document Aortofemoral Normal:

CPM Specifications Document Aortic Coarctation: Exercise

Deposited on: 21 January 2009

Research Article Effect of Pulsatile Flow Waveform and Womersley Number on theflowinstenosedarterialgeometry

Flow features in and around a (stented) coarctation

The Study of Abdominal Aortic Aneurysm Rupture Risk using Fluid-Structure Interaction

Exploring Blood Flow Dynamics Underlying Pathogenesis of Splenic Artery Aneurysms

3D Modeling of Plaque Progression in the Human Coronary Artery

Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics

BLOOD FLOW THROUGH A COMPOSITE STENOSIS IN CATHETERIZED ARTERIES INTRODUCTION

There has been extensive speculation in the literature about

Conference Paper Mathematical Modeling of Atherosclerotic Plaque Formation Coupled with a Non-Newtonian Model of Blood Flow

Identification of Atherosclerotic Lesion-Prone Sites through Patient-Specific Simulation of Low-Density Lipoprotein Accumulation

History of Vascular Modelling. William Harvey discovery of the circulation 1628

EVALUATION OF ABDOMINAL AORTIC ANEURYSM WALL STESS BASED ON FLOW INDUCED LOAD

Journal of Biomechanics

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta

Noninvasive Fractional Flow Reserve from Coronary CT Angiography

EasyChair Preprint. Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation

Study of Newtonian and Non-Newtonian Effect of Blood Flow in Portal Vein in Normal and Hypertension Conditions using CFD Technique

¼ density (kg/m 3 ) ij ¼ Reynolds stress tensor (kg/m-s 2 ) ! ¼ specific dissipation rate ("=k)

Fluid structure interaction modeling of aneurysmal conditions with high and normal blood pressures

An Evaluation of Proposed and Current Cardiovascular Stent Design Approaches to Aortoiliac Occlusive Disease

Transcription:

Vol:1, No:2, 27 Effect of Non-Newtonian Behaviour of Blood on Pulsatile Flows in Stenotic Arteries Somkid Amornsamankul, Benchawan Wiwatanapataphee, Yong Hong Wu, Yongwimon Lenbury International Science Index, Medical and Health Sciences Vol:1, No:2, 27 waset.org/publication/1528 Abstract In this paper, we study the pulsatile flow of blood through stenotic arteries. The inner layer of arterial walls is modeled as a porous medium and human blood is assumed as an incompressible fluid. A numerical algorithm based on the finite element method is developed to simulate the blood flow through both the lumen region and the porous wall. The algorithm is then applied to study the flow behaviour and to investigate the significance of the non-newtonian effect. Keywords stenotic artery, finite element, porous arterial wall, non-. I. INTRODUCTION FOR many decades, cardiovascular disease has been one of the most severe diseases causing a large number of deaths worldwide each year, especially in developed countries. Most of the cases are associated with some form of abnormal flow of blood in stenotic arteries. In the presence of a stenosis, the normal blood flow through the artery is disturbed resulting in blood recirculation and wall shear stress oscillation near the stenosis. The heart has to increase the blood pressure to impel the blood passing through the narrowing region so as to enforce the blood circulation. If the heart works too hard and the blood cannot flow well, heart attack may occur. In order to understand the blood flow behaviour in arteries so as to provide sufficient information for clinical purposes, intensive research has been carried out worldwide for both normal and stenotic arteries [1], [2], [3], [4], [5], [6]. Most analyses assumed the human blood to be Newtonian and the stenoses to be symmetric to make the problem more traceable [7], [8]. Various mathematical models and finite element based numerical methods have been developed to simulate blood flow through the stenotic arteries, including two-dimensional and three dimensional s and non-s [9], [1], [11], [12]. Althrough a large number of studies have led to better understanding of the flow behaviour induced by a stenosis, further analysis and development are still needed to accurately simulate blood flow under different conditions. One of the important aspects, in simulating blood flow, is to accurately describe the nature of blood as a fluid. It has been generally Manuscript received March 2,26. This work was supported by the Royal Thai Government, the Commission On Higher Education and the Australian Government through the 25 Australia Endeavour Chueng Kong Award. S. Amornsamankul and Y-H. Wu are with the Department of Mathematics and Statistics, Curtin University of Technology, WA 61 Australia (corresponding author phone: 618-9266-3142; email:somkid. amornsamankul@postgrad.curtin.edu.au). B.Wiwatanapataphee and Y. Lenbury are with the Department of Mathematics, Mahidol University, Bangkok 14 Thailand. Fig. 1. A cross section of the arterial vessel. accepted that blood behaves as a Newtonian fluid when the shear rate is greater than 1s 1 [13], [14], [15]. However, when the shear rate is lower than 1s 1, blood behaves as a non-newtonian fluid and the stresses depend nonlinearly on the deformation rate. Many models assume blood flow to be Newtonian, however, the instantaneous shear rate over a cardiac cycle may vary from zero to over 1s 1 depending on the circumstance. Therefore, it is useful to study the significance of non-newtonian effect on pulsatile blood flows. Hence, the aims of this study are two fold : to develop a finite element model to study the behaviour of blood flow through stenotic arteries taking into account of blood transport through the porous arterial wall, and to investigate the effect of non-newtonian viscosity of blood on pulsatile flow through an artery with an asymmetric or a symmetric stenosis over a cardiac cycle. II. MATHEMATICAL MODEL A blood vessel consists of several layers as shown in Fig. 1. Blood is transported mainly through the lumen but some could be transported through the porous layers including the lunica intima and lunica medium layers. In the lumen region, the equations governing the flow of blood include the continuity equation and the Navier-Stokes equations : u =, (1) International Scholarly and Scientific Research & Innovation 1(2) 27 18 scholar.waset.org/137-6892/1528

Vol:1, No:2, 27 TABLE I VALUES OF PARAMETERS USED IN COMPUTATIONAL REGION n α Q n θn Q α p n θn p 1 17.28 2.256-21.74 -.46 2-34.91 -.226-9.88.22 3-16.11 1.228 4.771 -.633 4 11.7 4.882 2.35-4.315 5 6.64 -.74.768 3.932 Fig. 2. mesh. The 3-D geometry of the 5% stenotic tubes and its finite element International Science Index, Medical and Health Sciences Vol:1, No:2, 27 waset.org/publication/1528 ρ ( u t + u u) = p 1 + (µ n ( u +( u) T )) + f, (2) where ρ denotes the blood density, u =(u 1,u 2,u 3 ) is the velocity vector, f =(f 1,f 2,f 3 ) is the volume force acting on the fluid, p 1 denotes pressure in the luminal channel, and µ n is the viscosity of blood. For Newtonian fluid, µ n is taken to be a constant. For non-newtonian fluid, µ n is a function of shear rate γ = 2D : D where D = 1 2 ( u +( u)t ) denotes the rate of deformation tensor. In this study we use the Carreau model for blood, namely µ n = µ +(µ µ )[1+(λ γ) 2 ] (n 1)/2, where µ, µ, λ, and n are constants. In the porous layer of the arterial wall, the flow of blood is described by the continuity equation and the Brinkman equations : v =, (3) ρ v t + µ κ v = p 2 + (µ ( v +( v) T )) + g, (4) where µ denotes the viscosity of blood in the porous layer, κ is the permeability of the porous media, v represents the velocity vector, p 2 denotes pressure in the wall, and g is the volume force acting on the fluid in the wall. To precisely describe the cyclic nature of the heart pump and the pulsatile flow condition in the arteries, we use Fourier series to represent the pulsatile pressure and flow rate in the arteries. Therefore, we impose a pulsatile flow rate condition on the inlet boundary and a corresponding pulsatile pressure condition on the outlet boundary of the computational region, namely, for i, j =1, 2, 3 u 1 =ū (t) = 1 A [ Q + 5 n=1 αq n cos( 2nπt T θ Q n )], u 2 = u 3 = on Ω in p = p + 5 n=1 αp ncos( 2nπt T θn), p ( ( )) µn u +( u) T n = on Ω out, (5) where A denotes the inlet cross section area of an artery, Q = 59.9 cm 3 /min, p = 122.5 mmhg are respectively the mean flow rate and mean pressure, T is the cardiac period, and the values of αn Q, αn, p θn Q, and θn p are listed in table I. On the interface between the lumen and the porous wall, the pressure and velocity are assumed to be continuous across the interface. On other wall surface, the no-slip condition is applied. Thus to this end, the boundary value problem for the investigated problem is BVP : Find u, p 1, v, p 2 such that (1) (4) are satisfied in the computation domain Ω=Ω L Ω W and all boundary conditions are satisfied. III. METHOD OF SOLUTION To develop the variational statement for the boundary value problem (BVP), we consider the following integral representation of the problem. Find p 1, u 1, u 2, u 3 and p 2, v 1, v 2, v 3 ɛ H 1 Ω such that for all test functions û i ɛh 1 u i (Ω), ˆv i ɛh 1 v i (Ω), and ˆp 1, ˆp 2 ɛh 1 (Ω), all the Dirichlet boundary conditions for the unknown functions are satisfied and ( u, ˆp 1 )=, (6) ρ ( u t + u u, û) ( µ n ( u +( u) T ), û ) +( p 1, û) =(f, û), (7) ( v, ˆp 2 )=, (8) ( ρ v t µ( v +( v)t ), ˆv ) + µ κ (v, ˆv) (9) +( p 2, ˆv) =(g, ˆv), where (, ) denotes the inner product on the square integrable function space L 2 (Ω), H 1 (Ω) is the Sobolev space W 1,2 (Ω) with norm 1,2,Ω,H 1 u i (Ω) = {vɛh 1 (Ω) v = on the boundary where u i is specified}. A standard procedure is then carried out to reduce the second-order derivatives involved in the above problem into the first-order ones using integration by parts to ensure that all integrals involved are well defined. Through a Galerkin finite element formulation, we obtain the following system M U + KU = F, (1) where U = (v f, v B, v w ) T in which v f and v w denote quantities in the lumen region and the porous wall region, and v B represents quantities on the interface between the lumen region and the porous wall region. A standard backward Euler scheme can then be used to solve the above system of ordinary differential equations to International Scholarly and Scientific Research & Innovation 1(2) 27 19 scholar.waset.org/137-6892/1528

Vol:1, No:2, 27 1 1 2 3.5 1.5 3 2.5 2 axial axis (cm) 3.5 International Science Index, Medical and Health Sciences Vol:1, No:2, 27 waset.org/publication/1528 (d) (e) Fig. 3. Vector plots of the velocity fields in the luminal channel at the peak of systole of the non- with 25% stenotic tube, with 5% stenotic tube, with 65% stenotic tube, (d) with symmetric type 5% stenotic tube, and (e) with symmetric type 8% stenotic tube. determine the velocity and pressure fields at any instant of time. IV. RESULTS AND DISCUSSION Using the numerical technique developed, a series of numerical experiments have been carried out to study the flow behaviour of blood through a porous medium stenosed artery and to investigate the significance of the non-newtonian effect on blood flow for various cases of stenosis severity. Here, in this section, we present results for some of the investigated cases to demonstrate the essential features of the blood flow through the porous medium stenotic arteries and to show the significance of non-newtonian effect on blood flow for the examined cases. Two different models, the and the non-newtonian Carreau model, are used in the modelling. Various cases of stenosis severity, ranging from 25% to 8%, are considered. The computation domain is a straight tube of length of 5cm and the diameter of the lumen is.21cm. The thickness of the wall is.5cm. Two different types of stenoses, asymmetric and symmetric as shown in Fig. 3, are considered in this work. The blood density is ρ =1.6g/cm 3, the Newtonian viscosity of blood is.345g/(cm s), the parameters in the non-newtonian Carreau model have values µ =.56g/(cm s), µ =.345g/(cm s), λ =3.313s, Fig. 4. Surface plot of wall shear stresses (WSS) on the 5% stenotic tube using the non-. and n =.3568, the parameters in the Brinkman equation have values µ =.345g/(cm s), and κ =1.e 14 cm 2. Fig. 3 shows the three-dimensional vector plots of the velocity field in the lumen region at the peak of systole obtained by using the Carreau model. The diagrams describe the general feature of blood flow through stenotic arteries with different degree of stenosis area-severity. It is noted that for the asymmetric case, when the stenosis area severity reaches 5%, a small flow recirculation zone occurs near the back toe of the stenosis where altherosclerotic diseases may develop. To demonstrate the feature of wall shear stress distribution, we plot the wall shear stress on the plane representing the wall surface where the stenosis is located at the centre as shown in Fig. 4. It is noted that large magnitudes of wall shear stresses occur near the throat of the stenosis. Fig. 5 shows the distributions of the axial velocity component u x on three different cross sections of the 5% stenosed artery at the peak of systole t =3.15s, obtained by both the and the non-newtonian Carreau model. On the upstream cross section x =2cm, the velocity profile is symmetric. On the downstream cross section x =2.7cm, the velocity profile is no longer symmetric and there exists a small region with low velocity. The results also clearly show that, for the problem examined, the non-newtonian property of blood has very significant effect on the velocity profiles particularly on the downstream cross section. Fig. 6 shows the pressure distributions along the axial line (x-axis) at the peak of systole t =3.15s, obtained by both the and the Carreau model. It is noted that the non-newtonian behaviour only slightly affects the pressure distribution. The results also indicate that as the degree of the stenosis area severity increases, the pressure gradient required to impel the blood passing through the narrowing channel increases significantly. This results in a higher pressure to occur in the up-stream region. Fig. 7 shows the effect of stenosis severity on blood pressure for the asymmetric case, obtained by using the non-newtonian model. The results clearly show how blood pressure increases as the degree of the stenosis severity increases. Fig. 8 shows the distributions of wall shear stresses (WSS) on three cross-sections of the 5% stenotic artery at the peak International Scholarly and Scientific Research & Innovation 1(2) 27 11 scholar.waset.org/137-6892/1528

Vol:1, No:2, 27 International Science Index, Medical and Health Sciences Vol:1, No:2, 27 waset.org/publication/1528 15 1 5 non.1.5.5.1 15 1 5 non.1.5.5.1 15 1 5 non.1.5.5.1 138 136 134 132 13 128 non 126 1 2 3 4 5 138 136 134 132 13 128 non 126 1 2 3 4 5 Fig. 6. Pressure along the axial line (x,.5, ) in the tube with different stenosis area severity at the peak of systole t =3.15s: 25%, and 5%. 145 14 135 13 25% stenosed 5% stenosed 65% stenosed Fig. 5. The velocity field u x in the lumen region of the 5% stenotic tube at the peak of systole t =3.15s : at an upstream cross section x =2. cm, at the throat cross section x =2.5 cm, and at a downstream cross section x =2.7 cm. 125 1 2 3 4 5 Fig. 7. Pressure along the axial line (x,.5, ) in the artery with different stenosis area severity at the peak of systole t =3.15s, obtained by the non-. International Scholarly and Scientific Research & Innovation 1(2) 27 111 scholar.waset.org/137-6892/1528

Vol:1, No:2, 27 of systole t =3.15s, obtained by using the and the non-newtonian Carreau model. It is clear that the non-newtonian behaviour has very significant effect on the magnitude of wall shear stresses. V. CONCLUSIONS A numerical technique has been developed to simulate the three dimensional pulsatile blood flow in stenotic arteries and to study the effect of the non-newtonian viscosity of blood on the flow behaviour. The results show that blood pressure increases very significantly in the upstream zone of the stenotic artery as the degree of the stenosis area severity increases. It is also shown that the non-newtonian behaviour of blood has significant effects on the velocity profile of the blood flow and the magnitude of the wall shear stresses. 65 7 75 non International Science Index, Medical and Health Sciences Vol:1, No:2, 27 waset.org/publication/1528 REFERENCES [1] F. Migliavacca, R. Yates, G. Pennati, G. Dubini, R. Fumero, and M. R. de Leval, Calculating blood flow from doppler measurements in the systemic-to-pulmonary artery shunt after the norwood operation: a method based on computational fluid dynamics, Ultrasound in Medicine and Biology, vol. 26, pp. 29 219, 2. [2] F. Migliavacca, G. Dubini, G. Pennati, R. Pietrabissa, R. Fumero, T.-Y. Hsia, and M. R. de Leval, Computational model of the fluid dynamics in systemic-to-pulmonary shunts, Journal of Biomechanics, vol. 33, pp. 549 557, 2. [3] F. Migliavacca, L. Petrini, M. Colombo, F. Auricchio, and R. Pietrabissa, Mechanical behavior of coronary stents investigated through the finite element method, Journal of Biomechanics, vol. 35, pp. 83 811, 22. [4] M. Oshima, R. Torii, T. Kobayashi, N. Taniguchi, and K. Tukagi, Finite element simulation of blood blow in the cerebral artery, Computer methods in applied mechanics and engineering, vol. 191, pp. 661 671, 21. [5] A. Redaelli, F. Boschetti, and F. Inzoli, The assignment of velocity profiles in finite element simulations of pulsatile flow in arteries, Computers in Biology and Medicine, vol. 27, pp. 233 247, 1997. [6] C. A. Taylor, T. J. Hughes, and C. K. Zarins, Finite element modeling of blood flow in arteries, Computer methods in applied mechanics and engineering, vol. 158, pp. 155 196, 1998. [7] K. Lee and X. Xu, Modelling of flow and wall behaviour in a mindly stenosed tube, Medical Engineering and Physics, vol. 24, pp. 575 586, 22. [8] B. Liu and D. Tang, A numerical simulation of viscous flows in collapsible tubes with stenose, Applied Numerical Mathematics, vol. 32, pp. 87 11, 2. [9] H. Jung, J. W. Choi, and C. G. Park, Asymmetric flows of nonnewtonian fluids in symmetric stenosed artery, Korea-Australia Rheology Journal, vol. 16, pp. 11 18, 24. [1] H. Hoogstraten, J. Kootstra, B. Hillen, J. Krijger, and P. Wensing, Numerical simulation of blood flow in an artery with two successive bends, Journal of Biomechanics, vol. 29, pp. 175 183, 1996. [11] T. Ishikawa, L. F. Guimaraes, S. Oshima, and R. Yamane, Effect of non-newtonian property of blood on flow through a stenosed tube, Fluid Dynamics Research, vol. 22, pp. 251 264, 1998. [12] C. Tu and M. Deville, Pulsatile flow of non-newtonian fluids through arterial stenoses, Journal of Biomechanics, vol. 29, pp. 899 98, 1996. [13] M. Bonert, J. G. Myers, S. Fremes, J. Williams, and C. R. Ethier, A Numerical Study of Blood Flow in Coronary Artery Bypass Graft Sideto-Side Anastomoses, in Annals of Biomedical Engineering, vol. 3, 22, pp. 599 611. [14] D.-Y. Fei, J. D. Thomas, and S. E. Rittgers, The Effect of Angle and Flow Rate Upon Hemodynamics in Distal Vascular Graft Anatomoses: a Numerical Model Study, Journal of Biomechanical Engineering, vol. 116, pp. 331 336, 1994. [15] M.-H. Song, M. Sato, and Y. Ueda, Three-Dimensional Simulation of Coronary Artery Bypass Grafting with the Use of Computational Fluid Dynamics, Surgery Today, vol. 3, pp. 993 998, 2. 8.1.2.3.4.5.6.7 2 2 4 6 8 1 non 12.1.2.3.4.5.6.7 1 5 5 1 15 non 2.1.2.3.4.5.6.7 Fig. 8. Distribution of wall shear stresses(wss) on three different cross sections of the 5% stenotic artery at the peak of systole t =3.15s : at x =2.cm, at x =2.5cm, and at x =2.7cm (The stenosis is at the centre). International Scholarly and Scientific Research & Innovation 1(2) 27 112 scholar.waset.org/137-6892/1528