RESEARCH AND REVIEWS: JOURNAL OF PHARMACOLOGY AND TOXICOLOGICAL STUDIES

Similar documents
Echocardiographic Evaluation of Mitral Valve Prostheses

W e have previously reported the results of a randomised

15-Year Comparison of Supra-Annular Porcine and PERIMOUNT Aortic Bioprostheses

Very Long-Term Survival Implications of Heart Valve Replacement With Tissue Versus Mechanical Prostheses in Adults <60 Years of Age

Update on Oral Anticoagulation for Mechanical Heart Valves

Surgery for Acquired Cardiovascular Disease

A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis

2017 Cardiovascular Symposium CARDIAC SURGERY UPDATE: SMALLER INCISIONS AND LESS COUMADIN DAVID L. SAINT, MD

Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience

Echo Evaluation of a Mitral Valve Prostheses Sunday, February 14, :50 2:10 PM 20 min

Late failure of transcatheter heart valves: An open question

42yr Old Male with Severe AR Mild LV dysfunction s/p TOF -AV Replacement(tissue valve) or AoV plasty- Kyung-Hwan Kim

Mechanical heart valves and Anticoagulation. Dr. Alkesh ZALA Basic Physician trainee, Dept. of Cardiology, John Hunter hospital.

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

Reoperation for Bioprosthetic Mitral Structural Failure: Risk Assessment

TSDA Boot Camp September 13-16, Introduction to Aortic Valve Surgery. George L. Hicks, Jr., MD

Spotlight on valvular heart disease guidelines. Prosthetic heart valves. Bernard Iung Bichat Hospital, Paris Diderot University Paris, France

Hemodynamics Benefit of Supra-Annular Design in Failed Bio-Prosthetic Valves

Cover Page. The handle holds various files of this Leiden University dissertation

Medtronic Mosaic porcine bioprosthesis: Assessment of 12-year performance

TAVR for Valve-In-Valve. Brian O Neill Assistant Professor of Medicine Department of Medicine, Section of Cardiology

EVERYTHING ABOUT MECHANICAL VALVES HAS CHANGED

A Surgeon s Perspective Guidelines for the Management of Patients with Valvular Heart Disease Adapted from the 2006 ACC/AHA Guideline Revision

Mitral Valve Surgery: Lessons from New York State

Clinical validation of a new drug seeking Food and

I will not discuss off label use or investigational use in my presentation.

CoreValve in a Degenerative Surgical Valve

UNDERSTANDING YOUR HEART VALVE. Mosaic Tissue Valve

16 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 6900

Carpentier-Edwards supra-annular aortic porcine bioprosthesis: Clinical performance over 20 years

Mitral valve replacement in patients under 65 years of age: mechanical or biological valves?

Biological or mechanical valve prosthesis?

Heart Valves: Before and after surgery

P have been used for mitral and aortic valve replacement

Choice of Prosthetic Heart Valve in Adults

Hani K. Najm MD, Msc, FRCSC FACC, FESC President Saudi Society for Cardiac Surgeons Associate Professor of Cardiothoracic Surgery King Abdulaziz

SREE CHITRA TIRUNAL INSTITUTE FOR MEDICAL SCIENCES AND TECHNOLOGY THIRUVANANTHAPURAM, KERALA, INDIA

Hardware in the Chest - From VADs to Valves

Indication, Timing, Assessment and Update on TAVI

Durability of Pericardial Versus Porcine Aortic Valves

Bioprostheses are prone to continuous degeneration

CLINICAL COMMUNIQUE 16 YEAR RESULTS

Department of Cardiothoracic Surgery, Heart and Lung Center, Lund University Hospital, Lund, Sweden

T sors in the following aspects: the porcine aortic valve

LONG-TERM OUTCOME AFTER BIOLOGIC VERSUS MECHANICAL AORTIC VALVE REPLACEMENT IN 841 PATIENTS

Prognosis after aortic valve replacement with St. Jude Medical bileaflet prostheses: impact on outcome of varying thromboembolic and bleeding hazards

PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic.

Transapical Transcatheter Aortic Valve Implantation in the Presence of a Mitral Prosthesis

Adult Cardiac Surgery

Surgical management of valve disease in the early 21st century

PROSTHETIC. V PROSTHETIC.V

Reconstruction of the intervalvular fibrous body during aortic and

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

Stainless Steel. Cobalt-chromium

Valvular Heart Disease

Hani K. Najm MD, Msc, FRCSC, FRCS (Glasgow), FACC, FESC President of Saudi Heart Association King Abdulaziz Cardiac Centre Riyadh, Saudi Arabia.

Transcatheter valve-in-valve implantation for degenerated surgical bioprostheses

Controversy exists regarding which valve type is best

Clinical material and methods. Copyright by ICR Publishers 2003

Read at the Twenty-fourth Annual Meeting of The Western Thoracic Surgical Association, Whistler, British Columbia, June 24-27, 1998.

The St. Jude Medical Biocor Bioprosthesis

Long-Term Results With the Medtronic-Hall Valvular Prosthesis

The CarboMedics bileaflet prosthetic heart was introduced

Iatrogenic pathology of the heart:

Nineteen-Millimeter Aortic St. Jude Medical Heart Valve Prosthesis: Up to Sixteen Years Follow-up

Does Patient-Prosthesis Mismatch Affect Long-term Results after Mitral Valve Replacement?

Nearly 40 years after the pioneering efforts of Starr and

Long-term Experience with the Bjork-Shiley Monostrut Tilting Disc Valve

Βαλβιδοπάθειες. Από ηις τειροσργικές ζηις διαδερμικές θεραπείες

Mechanical vs. Bioprosthetic Aortic Valve Replacement: Time to Reconsider? Christian Shults, MD Cardiac Surgeon, Medstar Heart and Vascular Institute

CARPENTIER-EDWARDS PERICARDIAL VALVES IN THE MITRAL POSITION: TEN-YEAR FOLLOW-UP

Durability and Outcome of Aortic Valve Replacement With Mitral Valve Repair Versus Double Valve Replacement

S ince the two large randomised trials of the 1970s

TAVR in patients with. End-Stage CKD or in Renal Replacement Therapy:

by Age Groups W. R. E. Jamieson, M.D., L. J. Rosado, M.D., A. I. Munro, M.D., A. N. Gerein, M.D., L. H. Burr, M.D., R. T. Miyagishima, M.D.

Transcatheter aortic valves in aortic regurgitation Gry Dahle Dept of Cardiothoracic- and vascular surgery Rikshospitalet, Oslo University Hospital,

THE IMPACT OF AGE, CORONARY ARTERY DISEASE, AND CARDIAC COMORBIDITY ON LATE SURVIVAL AFTER BIOPROSTHETIC AORTIC VALVE REPLACEMENT

Durability of Mitral Valve Surgery: Repair, Replacement or simply a clip? Christoph Huber Chirurgie Cardio Vasculaire HUG

Transcatheter Aortic Valve Replacement

Primary Tissue Valve Degeneration in Glutaraldehvde-Preserved Porcine Biomostheses: Hancock I Vekus Carpentier-Edwards at 4- to 7-Years Follow-up

Aortic stenosis (AS) remains the most common

TAVI Versus Suturless Valve In Intermediate Risk Patients

Surgery for Valvular Heart Disease. Reoperation of Left Heart Valve Bioprostheses According to Age at Implantation

Treatment of Bio-Prosthetic Valve Deterioration Using Transcatheter Techniques

Next Generation Therapies: Aortic, Mitral and Beyond

Stentless aortic valve replacement in the young patient: long-term results

A prospective evaluation of the Bjbrk-Shiley, Hancock, and Carpentier-Edwards heart valve prostheses

P substitutes since the introduction of the Ionescu-

Incidence of prosthesis-patient mismatch in patients receiving mitral Biocor porcine prosthetic valves

Valvular heart disease (VHD) is present in 2.5% of the

25 different brand names >44 different models Sizes mm

A valve was initiated at the Medical University of

A Practical Approach to Prosthetic Valves

Ball Valve (Smeloff-Cutter) Aortic Valve Replacement Without Anticoagulation

Late incidence and determinants of reoperation in patients with prosthetic heart valves q

Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data

Surgical Treatment for Valvular Heart Disease

Influence of patient gender on mortality after aortic valve replacement for aortic stenosis

Surgery for Acquired Cardiovascular Disease ACD

PARTNER 2A & SAPIEN 3: TAVI for intermediate risk patients

Transcription:

e-issn:2322-0139 RESEARCH AND REVIEWS: JOURNAL OF PHARMACOLOGY AND TOXICOLOGICAL STUDIES Comparative Evaluation of Safety Outcomes of Different Prosthetic Valves in Indian Subjects. Kama Raval 1 *, Reena Desai 1, and Parloop Bhatt 2. 1 Shri Sarvajanik Pharmacy College, Sarvajanik Campus, Near Arvind Baug, Mehsana, Gujarat 384001, India. 2 CIMS Hospital, Ahmedabad, Gujarat, India. Review Article Received: 15/04/2014 Revised: 05/05/2014 Accepted: 10/05/2014 *For Correspondence Shri Sarvajanik Pharmacy College, Sarvajanik Campus, Near Arvind Baug, Mehsana, Gujarat 384001, India. Keyword: Prosthetic valve, Biological valve, Mechanical valve, Safety parameters ABSTRACT Prosthetic heart valves are commonly used in the treatment of valvular heart disease. Choice of heart valve in the developing countries is an unsettled issue due to illiteracy and noncompliance related increase in incidences of stuck valve and anticoagulant related bleeding and as such international guidelines may not be wholly applicable. The aim of our study was to compare outcomes after mitral, aortic or double valve replacements with mechanical versus bioprosthetic valves. The outcomes will include incidence of mortality, reoperations, bleeding, thromboembolism, and endocarditis. INTRODUCTION The introduction of valve replacement surgery in the early 1960s has dramatically improved the outcome of substitutes are now implanted in patients with valvular heart disease. Approximately 280 000 worldwide each year; approximately half are mechanical valves and half are bioprosthetic valves. Despite the marked improvements in prosthetic valve design and surgical procedures over the past decades, valve replacement does not provide a definitive cure to the patient. Instead, native valve disease is traded for prosthetic valve disease, and the outcome of patients undergoing valve replacement is affected by prosthetic valve hemodynamics, durability, and thrombogenicity. Nonetheless, many of the prosthesisrelated complications can be prevented or their impact minimized through optimal prosthesis selection in the individual patient and careful medical management and follow-up after implantation [1]. Prosthetic heart valves used for the definitive treatment of disease and dysfunctional native heart valves. They are broadly divided into mechanical heart valves (MHVs) and bioprosthetic heart valves (BHVs). MHVs are made of synthetic material (e.g., polymers, metal, and carbon), whereas BHVs are made of biologic tissues which are mounted on a fabric covered plastic frame, called a stent. MHVs are more durable, but their thrombogenicity and need for long-term anticoagulant therapy make them unsuitable for patients in some age groups especially older age groups. In contrast, BHVs are safe to implant, functionally similar to the native aortic valve, do not require long-term anticoagulant therapy, and are hence associated with reduced risk of hemorrhage. Since their introduction in the mid-1960s, BHVs have gone through many modifications, in their handling from time of harvesting to availability for implantation. Many tissues and different animal species aortic valves have been tried with varying results. Today, the most commonly used BHVs are those from porcine aortic valves and from calf pericardium. While the use of either one may be guided by patient age and other considerations, the trend in the India and Europe has been towards greater use of tissue rather than mechanical valves [2]. RRJPTS Volume 2 Issue 3 July - September, 2014 19

Types of Prosthetic Heart Valve Design e-issn:2322-0139 Mechanical Valves The current designs for the aortic and mitral positions include ball-and-cage valves, single tilting disc prostheses, and bileaflet prostheses. The bileaflet prostheses are manufactured by St. Jude, CarboMedics, ATS Medical, and On- X and are the most commonly used mechanical prostheses in the aortic position. They are unlike the other mechanical prostheses because they are mechanically stable and are hemodynamically efficient. Mechanical prosthetic valves are intended to last a lifetime, decreasing the risk of reoperation. A disadvantage to mechanical valves is the risk of thromboembolism. Warfarin, an anticoagulant must be taken concurrently for the duration of the patient s life. Warfarin requires constant monitoring of the prothombin time and international normalized ratio (INR) which requires frequent postoperative follow-up appointments. Also, because warfarin is a blood thinner, the risk of bleeding is higher. Three basic types of mechanical valve design exist: bileaflet, monoleaflet, and caged ball valves (Figure 1A, 1B, and 1C). Figure 1 Different types of prosthetic valves. A, Bileaflet mechanical valve (St Jude); B, monoleaflet mechanical valve (Medtronic Hall); C, caged ball valve (Starr-Edwards); D, stented porcine bioprosthesis (Medtronic Mosaic); E, stented pericardial bioprosthesis (Carpentier-Edwards Magna); F, stentless porcine bioprosthesis (Medtronic Freestyle); G, percutaneous bioprosthesis expanded over a balloon (Edwards Sapien); H, self-expandable percutaneous bioprosthesis (CoreValve) [3]. Caged Ball Valves Caged ball valves, which consist of a silastic ball with a circular sewing ring and a cage formed by 3 metal arches, are no longer implanted. However, several thousands of patients still have caged ball valves, and these patients require follow-up. Monoleaflet Valves Monoleaflet valves are composed of a single disk secured by lateral or central metal struts. The opening angle of the disk relative to valve annulus ranges from 60 to 80, resulting in 2 distinct orifices of different sizes. Bileaflet Valves Bileaflet valves are made of 2 semilunar disks attached to a rigid valve ring by small hinges. The opening angle of the leaflets relative to the annulus plane ranges from 75 to 90, and the open valve consists of 3 orifices: a small, slit-like central orifice between the 2 open leaflets and 2 larger semicircular orifices laterally. RRJPTS Volume 2 Issue 3 July - September, 2014 20

Bioprosthetic Valves e-issn:2322-0139 The bioprosthetic valves are treated chemically for transplantation to the human heart. Bioprosthetic valves are not as durable, have a shorter lifespan and are more susceptible to calcification than human and mechanical valves. Risk for reoperation is higher for younger patients receiving a bioprosthetic valve. The advantage to bioprosthetic valves is that unlike mechanical valves, they do not require lifelong anticoagulant therapy. Selection on the type of prosthetic valve is based on the age of the patient, valve position, comorbidity, and the risks and benefits of anticoagulation. Although, the selection process has some defined basis, much of the decision depends on the logic and experience of the surgeon. The current recommendation by the American Heart Association/American College of Cardiology (AHA/ACC) is to perform a mechanical prosthesis for aortic valve replacement (AVR) in patients with a mechanical valve in the mitral or tricuspid position already in place or who is under 65 years old without contraindication to anticoagulants. In addition, a mechanical prosthesis should be considered for mitral valve replacement (MVR) in patients under 65 years old with long-standing atrial fibrillation. Bioprosthetic valves are recommended in the aortic position in patients who are over 65 years old and thromboembolism risk free. In the mitral position, bioprosthetic valves should be considered in patients who are over 65 years old or are unable to take anticoagulants. The patient may choose either valve against the recommendations of the AHA/ACC guidelines or surgeon, as long as the risk of anticoagulant therapy versus reoperation has been discussed in detail with the patient. Bioprosthetic replacement heart valves are derived from human (homograft) or animal (xenograft) tissues. Homograft These are derived from cadaveric (human) aortic valves. They are cryopreserved and are implanted into the aortic root without a stent. Autograft. Patient s own valve was taken from one site (pulmonary) and implanted at another site, for example, pulmonary valve grafted into the aortic site. This predominately occurs in children with diseased native aortic valves [4]. Xenograft or Heterograft These are developed from animal tissues the most common being the porcine aortic valve followed by calf (bovine) pericardium. Porcine aortic valve In porcine BHV, the valve tissue is sewn onto a fabric covered metal wire stent, made from a cobalt-nickel or another alloy. A Dacron fabric covers the entire stent and a sewing skirt is fashioned and attached to the base of the wire stent. Contemporary models of these valves are durable and last for 10 15 years [4]. Bovine Pericardial Valve Similar in design to porcine valves in that they imitate the tricuspid aortic valve, except that the metal cylinder joining the ends of stent wire is located in the middle of one of the stent post loops. At 10 years after implantation, the hemodynamics and durability of pericardial valves are equal to or greater than the porcine valves [5]. Stentless Valves In bioprosthesis, as in MHV, the presence of the stent and the fabric sewing cuff leads to a residual stenosis of up to 20%. Stentless valves are meant to avoid this and to improve hemodynamics. They are made by removing the porcine aortic root and adjacent aorta en-block. The coronary arteries are tied off and the device can be trimmed as desired. The absence of a stent and sewing cuff avoids or at least minimizes residual stenosis and facilitates implantation of a larger BHV, which would enhance hemodynamics and patient survival [6]. RRJPTS Volume 2 Issue 3 July - September, 2014 21

Ideal prosthetic valve e-issn:2322-0139 The ideal prosthetic valve that combines excellent hemodynamic performance and long-term durability without increased thromboembolic risk or the need for long-term anticoagulation does not exist. [7] Hence, patients and their physicians need to choose between a mechanical and a tissue (bioprosthetic) valve. In general, the advantageous durability of mechanical valves is offset by the risk of thromboembolism and the need for long-term anticoagulation and its associated risk of bleeding. In contrast, bioprosthetic valves do not require long-term anticoagulation yet carry the risk of structural failure and reoperation [8]. Valve-related complications The initial concept that bioprostheses are associated with a lower embolic rate is disproven in patients who have similar baseline characteristics. This is also not surprising because there is a wide range of the incidence of these and other complications with the use of identical valve types [9,10] indicating complication rates are most likely due to patient related factors in the different studies and to differences in criteria of diagnosis and ascertainment of complications [10,11]. The patients in this trial had one or more risk factors for thromboembolism, which would be expected to be equally distributed between the mechanical and bioprosthetic groups in a randomized trial such as the present one. Furthermore, the follow-up in trial was 97% complete, and the determination of valve-related complications and causes of death were made by consensus of a committee of three who were blinded to valve type. With the use of a mechanical valve, there were no primary valve failures with AVR and only one with MVR; the latter was not due to structural valve deterioration. The incidence of primary valve failure, reoperation and mortality was lower after AVR with use of the mechanical valve. With a lower rate of primary valve failure in those aged 65 years. Safety parameters An observational study by Khan et al. retrieved data from a computerized database, where the study enrolled patients who had undergone an aortic, mitral or combined aortic and mitral valve replacement with a bioprosthetic. In the first study, patients who underwent bioprosthetic and mechanical valve implantations for AVR and MVR reported having similar survival over a 20 year follow- up period. Reoperation was similar at 5 years between mechanical and bioprosthetic valves, but was notably different by 10 and 15 years. Bioprosthetic valve recipients had a higher rate of reoperation especially in patients who underwent double bioprosthetic valve replacement. The risk of reoperation increased progressively with time in isolated bioprosthetic MVR and AVR recipients. There was a higher incidence of bleeding in mechanical valve recipients in the aortic position, but incidence of bleeding in bioprosthetic and mechanical valve recipients was similar for MVR. Reported cases of embolism and endocarditis for AVR and MVR were insignificantly different in bioprosthetic and mechanical valve recipients. In the second study by Hammermeister we found, survival was similar in bioprosthetic and mechanical valve recipients in the mitral position, but mechanical valve recipients in the aortic position had better survival. Reoperation was higher in patients who underwent a bioprosthetic valve implantation in the aortic position. In the mitral position, reoperation was similar. Bleeding was reported more frequently in mechanical valve recipients in both aortic and mitral valve positions. Cases of embolism and endocarditis for AVR and MVR were insignificantly different in bioprosthetic and mechanical valve recipients. In the last study by Oxenham et al., overall survival was similar in both bioprosthetic and mechanical valve recipients for AVR and MVR after a mean follow-up of 20 years. In addition, Oxenham et al. reported survival with the original prosthesis was better in mechanical valves for MVR. Reoperation was higher in bioprosthetic valve recipients than mechanical valve recipients for AVR and MVR. Bjork-Shiley mechanical valve recipients reported higher incidence of bleeding than bioprosthetic valve recipients for AVR and MVR. Like the previous two studies by Khan et al. and Hammermeister et al., embolism and endocarditis cases were similar in numbers and insignificantly different in both bioprosthetic and mechanical valve recipients. The principal long-term findings of randomized trial are: RRJPTS Volume 2 Issue 3 July - September, 2014 22

e-issn:2322-0139 Use of a mechanical valve resulted in a lower mortality and a lower reoperation rate after AVR. The mortality after MVR was similar with the use of the two prosthetic valve types. There were virtually no primary valve failures with the use of a mechanical valve. Primary valve failure after AVR and MVR occurred more frequently in patients with a bioprosthetic valve, especially in patients aged <65 years. The primary valve failure rate between bioprosthesis and mechanical valve was not significantly different in those aged 65 years. Use of a bioprosthetic valve resulted in a lower bleeding rate. There were no significant differences between the two valve types with regard to other valve-related complications, including thromboembolism and all complications [12]. Mortality risk is not different after mechanical and after tissue valve replacement [13,14]. A 50-yearold patient should anticipate at least 1 reoperation after bioprosthetic valve replacement, but overall, valve-related morbidity is far higher after mechanical valve replacement. Most studies of results of mechanical valve replacement have been observational studies of the results of valve replacement with one type of prosthesis. Most have shown excellent long term results for prosthesis survival, with no difference in durability between types of prosthesis [15]. There have been few randomised controlled trials comparing outcomes after mechanical valve replacement. Thromboembolism has been reported as occurring at a higher rate following Starr-Edwards replacement than Bjork-Shiley. Bileaflet prostheses such as the St Jude valve appear to have the lowest risk of thromboembolism. Rates of thromboembolism are higher following mitral valve replacement than following aortic valve replacement [16,17]. Several studies have identified porcine valve failure seven or more years after implantation, particularly in younger patients. One study compared results with stentless porcine prostheses with stented prostheses in the aortic position in a non-randomised case controlled study of patients undergoing aortic valve replacement, and showed apparently enhanced durability of the stentless prosthesis. [18] Advocates of the stentless prosthesis point to its superior haemodynamics with an effective valve area some 10% larger than stented prosthesis of equivalent size. CONCLUSIONS Based on the evidence of this systematic review, the implications and recommendations for practice is to consider a mechanical prosthetic valve in patients, who have a life expectancy of at least 10 years and do not have contraindication to anticoagulant therapy.. Bioprosthetic valves should be considered in patients, who have a life expectancy of less than 10 years or have contraindication to anticoagulant therapy. Better survival with a mechanical valve implantation in AVR and similar survival with bioprosthetic and mechanical valve replacement in MVR was reported in two studies, while the third study reported similar survival in both valve groups. The two randomized control trials reported higher occurrence of bleeding in mechanical valve recipients. The observational study reported higher occurrence in bleeding in mechanical valve recipient for AVR. There were no differences in the number of embolism or endocarditis cases between the two valve groups. MHVs are more durable than BHVs. Patient age and compliance are the important factors which govern the use of prosthetic heart valves. Recently in India the trend favors the use of BHVs because they are safe to implant, similar to the native aortic valve both morphologically and functionally, do not require long-term anticoagulant therapy, and are associated with reduced risk of hemorrhage. Mechanical valves are associated with a significantly higher complication rate compared with biological valves in Indian patients. Biological valves thus maybe specifically suited to the Indian scenario. However, in choosing a prosthetic valve, patients involvement and informed consent should take the utmost importance. REFERENCES 1. Bloomfield P, Wheatley D.J, Prescott R.J, Miller H.C; Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses. N Engl J Med. 324 1991:573-579. 2. A Vahanian, H Baumgartner, J Bax et al. Guidelines on the management of valvular heart disease: the task force on the management of valvular heart disease of the European society of cardiology. European Heart J. 2007;28(2):230 268. 3. Choice of prosthetic heart valves: update for the next generation. J Am Coll Cardiol. 2003; 42: 1717 17193. RRJPTS Volume 2 Issue 3 July - September, 2014 23

e-issn:2322-0139 4. RF Siddiqui, JR Abraham, J Butany. Bioprosthetic heart valves: modes of failure. Histopathol. 2009;55(2):135 144. 5. LH Edmunds, RE Clark, LH Cohn, GL Grunkemeier, DC Miller, RD Weisel. Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ann Thoracic Surg. 1996;62(3):932 935. 6. XY Jin, K Dhital, K Bhattacharya, R Pieris, N Amarasena, R Pillai. Fifth-year hemodynamic performance of the Prima stentless aortic valve. Ann Thoracic Surg. 1998;66(3):805 809. 7. Hammermeister KE, Henderson WG, Burchfiel C. Comparison of outcome after valve replacement with a bioprosthesis versus a mechanical prosthesis. Initial five year results of a randomized trial. J Am Coll Cardiol. 1987;10:719-732. 8. Cribier A, et al. Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. J Am Coll Cardiol. 2004; 43: 698 703. 9. Webb JG, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation. 2006; 113: 842 850. 10. Grube E, et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding Core Valve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol. 2007; 50: 69 76. 11. Rahimtoola SH. Lessons learned about the determinants of the results of valve surgery. Circulation.1988;78:1503-1507. 12. Oxenham H, Bloomfield P, Wheatley DJ, Lee RJ, Cunningham J, Prescott RJ, Miller HC. Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.heart. 2003; 89: 715 721. 13. Lund O, Bland M. Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement.j Thorac Cardiovasc Surg. 2006; 132: 20 26. 14. Chan V, Jamieson WRE, Germann E, Chan F, Miyagishima RT, Burr LH, Janusz MT, Ling H, Fradet GJ Performance of bioprostheses and mechanical prostheses assessed by composite of valverelated complications to 15 years after aortic valve replacement. J Thorac Cardiovasc Surg. 2006; 131: 15. Mandiye SS, Agarwal S. Comparison over short term of mortality and morbidity of mechanical and bioprosthetic heart valves in the Indian population. Indian J Thorac Cardiovasc Surg. 2010;139-142 16. Vongpatanasin W, Hillis LD, Lange RA. Prosthetic heart valves. N Engl J Med. 1996; 335:407 16. 17. Bonow RO, Carabello B, DeLeon AC, et al. ACC/AHA practice guidelines.guidelines for the management of patients with valvular heart disease. J Am Coll Cardiol. 1998; 32:1486 588. 18. David TE, Puschmann R, Ivanov J, et al. Aortic valve replacement with stentless and stented porcine valves: a case-match study. J Thorac Cardiovasc Surg. 1998; 116:236 41. RRJPTS Volume 2 Issue 3 July - September, 2014 24