X-spine Surgical Technique

Similar documents
Single-Thread Screw Available in 25-45mm lengths (5mm Increments) Dual-Thread Screw Available in 30-45mm lengths (5mm Increments)

Valencia Pedicle Screw Surgical Technique

Y o u r Id e a s En g i n e e r e d t o Li f e

HydraLok. Operative Technique. Polyaxial Pedicle Screw System

EXCELLA ll. Spinal System


USS Variable Axis Screw (VAS) System. For posterior fixation of the lumbar spine.

Dymaxeon Spine System. Simple, Streamlined, Smart. Surgical Procedure

L8 Spine System SURGICAL TECHNIQUE. Add: No.1-8, Tianshan Road, Xinbei District, Changzhou, Jiangsu, China

Threshold Pedicular Fixation System Surgical Technique

A U X I L I A R Y C O N N E C T O R S Surgical Technique

operative technique Universal Application

The Most Reliable Spinal Solution

VTI INTERLINK PEDICLE SCREW SYSTEM

Thunderbolt. surgical technique. MIS Pedicle Screw System. Where Nimble and Secure Intersect

SURGICAL TECHNIQUE GUIDE SOLANAS. Posterior Cervico-Thoracic Fixation System Adjustable Bridge System

Technique Guide. Universal Spinal System (USS). Designed to achieve the goals of scoliosis surgery.

MATRIX Spine System Deformity

A Fusion of Versatility, Performance and Ease.

Royal Oak Cervical Plate System

MATRIX Spine System Deformity. A posterior pedicle screw, hook, and rod fixation system.

Ref: Q400-09T1 EBI Spine. September 05/VS02. c/o BIOMET Spain Orthopaedics, S.L.

SURGICAL TECHNIQUE. SECURIS Pedicle Screw System for Minimally Invasive Surgery. 2 I SECURIS Pedicle Screw System

EXPEDIUM 5.5 Spine System Family Product Catalogue

VERTEX SELECT. surgical technique. adjustability. Flexibility. adaptability. Reconstruction System

Technique Guide. NFlex. Semi-rigid rods for posterior lumbar stabilization.

PRODUCT SUMMARY Cobalt Chrome Tulip Multiple Options Triple Lead Thread

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY - REDUCTION SCREWS. Surgical Technique. Hip Knee Spine Navigation

TiLock 2 Spinal System. Surgical Technique

I. II. SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE

100 Interpace Parkway Parsippany, NJ

ONE SYSTEM, MULTIPLE OPTIONS. Surgical Technique. Hip Knee Spine Navigation

MATRIX Spine System Degenerative. A posterior pedicle screw and rod fixation system.

AccuVision Minimally Invasive Spinal Exposure System

Dual-Opening USS. For deformity correction.

Zimmer Facet Screw System Surgical Technique

Occipital Cervical Fusion System. Implants and instruments designed to optimize fixation to the occiput.

SerratoTM. Surgical technique

The CerviFix System. Including the StarLock Components. CerviFix Clamp and Screw. StarLock Clamp and Screw

Surgical Technique FOR U.S. DOMESTIC USE ONLY

Zimmer Anterior Buttress Plate System. Surgical Technique

Veyron -C Anterior Cervical System Surgical Technique

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

4.5 System. Surgical Technique. This publication is not intended for distribution in the USA.

SURGICAL TECHNIQUE GUIDE TRESTLE. Anterior Cervical Plating System

SURGICAL TECHNIQUE. Standard Reduction HA Coated Modular. Discover the Difference

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

Technique Guide. Pangea Spine System. Top loading pedicle screw and hook system for posterior stabilization and correction of spinal deformities.

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

O PE RATIV E TE C HN IQ U E. Minimally Invasive Posterior Fixation

Surgical Technique. Occipito-Cervico-Thoracic System

ACP. Anterior Cervical Plate System SURGICAL TECHNIQUE

TM TM Surgical Technique

ONE SYSTEM, MULTIPLE OPTIONS. Surgical Technique

Trinica and Trinica Select Anterior Cervical Plate System

Biomet Omega21 TM Spinal Fixation System

Royal Oak IBFD System Surgical Technique Posterior Lumbar Interbody Fusion (PLIF)

Handling instructions. USS Low Profile. Thoracolumbar posterior fixation system.

EXPEDIUM VERSE Spinal System

Dynesys Top-Loading System

Ballista Percutaneous Screw Placement System

XRL A modular expandable radiolucent vertebral body replacement system

TiLock XT Minimally Invasive Surgery (MIS) Pedicle Screw System

Technique Guide MAXIMUM ACCESS SURGICAL PLATFORM

Solitaire Anterior Spinal System

Surgical Technique. Available In Titanium And Stainless Steel

USS Variable Axis Screw

As edited by Dr. Oheneba Boachie-Adjei, Dr. Matthew Cunningham, Dr. John Kostuik, Dr. Raymund Woo and the Complex Spine Study Group et al

Imola Lateral IBF System Surgical Technique

Cervical Solutions. Optio-C Anterior Cervical Plate. with Allograft/Autograft. Surgical Technique Guide

VECTRA-T SURGICAL TECHNIQUE. The Translational Anterior Cervical Palate System. This publication is not intended for distribution in the USA.

Ballista Percutaneous Screw Placement System. Surgical Technique

Thoracolumbar Solutions. Vital Spinal Fixation System. Degenerative. Surgical Technique Guide

EXCELLA MIS. Spinal System

Table of Contents.

X-spine Systems, Inc. X90 Pedicle Screw System

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

LUMBAR POSTERIOR MINIMALLY INVASIVE SYSTEM. Surgical Technique

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

BAK/C Cervical Anterior Interbody Fusion System

TSLP Thoracolumbar Spine Locking Plate

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

TABLE OF CONTENTS. Vault C Anterior Cervical Discectomy 2 and Fusion (ACDF) System Overview. Implants 3. Instruments 5. Surgical Technique 10

M.I.S. MAKE IT SMART IN ONE SYSTEM. Surgical Technique. Hip Knee Spine Navigation

Introduction. Our hope is that this Surgical Technique Guide enhances your knowledge and contributes to clinical success for your patients.

UNIQUE ANATOMIES PATIENT-MATCHED SOLUTIONS. Surgical Technique

SURGICAL TECHNIQUE MANUAL. InterFuse T

USS II ILIO-SACRAL Modular System for Stable Fixation in the Sacrum and Illium

OPERATIVE TECHNIQUE. anterior cervical plating system

Technique Guide. MATRIX Spine System MIS Instrumentation. The total solution for simple and complex spine pathology.

Surgical Technique 4.5/8.5MM BEAMING SYSTEM. Customer Service:

Xia 3 Spinal System. AIS surgical technique

Thoracolumbar Anterior Compression (TAC) System. Allows distraction, compression, and lateral fixation of the lower thoracic and lumbar spine.

Synex System TECHNIQUE GUIDE. An expandable vertebral body replacement device

L-VARLOCK. Posterior Lumbar Cage with adjustable lordosis. S urgical T echnique

The Versatile Polyaxial Solution for the Universal Spine Systems. USS II Polyaxial. Surgical Technique

Transcription:

X-spine Surgical Technique The X90 Pedicle Screw System Revolutionary Design and Function

This document is intended exclusively for experts in the field, particularly physicians, and is not intended for laypersons. Information on the products and procedures contained in this document is general in nature and does not represent medical advice or recommendations. As with any technical guide, this information does not constitute any diagnostic or therapeutic statement with regard to a given medical case. An evaluation, examination, and advising of the patient are absolutely necessary for the physician to determine the specific requirements of the patient, and any appropriate adjustments needed, and the foregoing are not to be replaced by this document in whole or in part. Information contained in this document was gathered and compiled by experts in the field and X-spine employees to the best of their knowledge. Care was taken to ensure the information contained herein is accurate and understandable. X-spine does not assume any liability, however, for the accuracy and/or completeness of the quality of the information, and X-spine is not liable for any losses whatsoever of any kind or any nature that may be caused by the use of said information.

X-spine Surgical Technique The X90 Pedicle Screw System Revolutionary Design and Function Introduction The X-spine X90 Pedicle Screw System consists of titanium alloy bone screws, rods, cross-connectors and associated instruments. The system utilizes a unified screw-rod locking interface, and is indicated for attachment to the pedicles of the thoracic, lumbar and sacral spine. This technique guide is for informational purposes and is not intended as a substitute for appropriate surgical training and judgment. The X90 Pedicle Screw System is indicated for the treatment of severe spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion. In addition, the system is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis). Please refer to the package insert for specific labeling limitations and information. CAUTION Failure to incorporate appropriate anterior support for a posterior pedicle screw construct may result in abnormal loading, failure or loosening of the construct. Patient Positioning and Approach The patient is positioned on the operating table in the prone position. The patient should be positioned on an appropriate support frame in order to minimize intraabdominal pressure to avoid venous congestion, excess intraoperative bleeding and allow adequate ventilation under anesthesia. The patient s hips should be extended to preserve lumbar lordosis for fusion and instrumentation of the lumbosacral junction. The spine is exposed via a posterior surgical approach. Decortication and bone grafting is performed per desired technique. Meticulous fusion techniques are critical for success of the procedure. The X90 Pedicle Screw System is intended to be used in conjunction with anterior column support, such as interbody structural bone graft placement or vertebral body replacement device. Failure to place anterior column support may result in premature failure and/or loosening of any pedicle screw system. The pedicles are identified using standard surgical landmarks and their position is confirmed using AP and lateral intraoperative fluoroscopy or radiography. 1

Step 1 A Bone Awl is used to penetrate the cortical bone at the pedicle entry point. The pedicle entry zone is identified and should be decorticated and free of osteophytes to allow for proper polyaxial motion of the screws. Step 2 A Pedicle Probe is used to create a pilot hole for the pedicle screw. The Pedicle Probe is driven into the pilot hole and pedicle under radiological guidance. Note the depth markings on the side of the instrument. Straight and Curved Probes are available. It is recommended that electrophysiological testing of the probe be performed to rule out abnormal conductance between the Probe and the nerve root. Step 3 A Ball-Tipped Pedicle Sounder is used to confirm there is no pedicle wall violation prior to screw placement. Straight and Curved Sounders are available. 2

Step 4 Using preoperative and intraoperative radiographs, the appropriate pedicle screw size is determined. The screws are available in 4.75, 5.5, 6.5, 7.5 and 8.25mm widths and 30, 35, 40, 45, 50 and 55mm lengths. An appropriately sized Thread Tap is used to tap the pilot hole. It is recommended that the Tap be rotated only deep enough to facilitate initial screw purchase. Taps for all diameter screws are available. Taps are undersized approximately 10% to allow for improved cancellous bone purchase. CAUTION Selection of an oversized screw and/or tap can result in pedicle fracture with loss of fixation and/or neurological injury. Step 5 The Pedicle Screw is placed on the tip of the Locking Pedicle Screwdriver. The Screwdriver Handle must first be placed in the neutral, non-ratcheting position for screw engagement. The screw shaft may need to be rotated slightly for the male and female hex couplings to align for engagement. The tabs of the Screwdriver tip should line up with the slots on the top of the screw. Step 6 The Locking Sleeve of the Pedicle Screw Locking Driver is advanced such that sleeve tabs engage the top of the Pedicle Screw. This step should be performed with the screw in the screw caddy or resting upon a sterile surface to avoid premature screw disengagement. Step 7 The Pedicle Screw Locking Driver Sleeve is rotated clockwise by hand until increasing resistance is felt. Rotating the Locking Driver Sleeve will firmly lock the screw onto the driver and prevent screw toggling under lateral forces. 3

Step 8 The Pedicle Screw is driven into the pedicle using the Pedicle Screw Locking Driver. The Locking Sleeve may be retracted towards the Screwdriver Handle for improved visualization. Prior to placement, the screw size should be confirmed by direct measurement using the Screw Gauge located on the side of the screw caddy and re-confirmed by reading the screw size engraved into the screw top. The screw should be driven from 50 to 67% of the AP dimension of the vertebral body and centered within the pedicle. Intraoperative radiography and electrophysiology should be used to confirm screw position. The screw should be driven into the pedicle such that the polyaxial top retains appropriate range of motion. Step 9 Once the screw is in the proper position, the Locking Sleeve tabs are engaged into the top of the screw and the Locking Sleeve is rotated counter-clockwise to disengage the screw. CAUTION Placement of the Pedicle Screw outside of the pedicle can result in neurological injury, vascular injury, and/or inadequate fixation. CAUTION Placement of high torque force during screw tightening may result in stripping of bone and weakening of the bone/screw interface. If screw stripping or other compromise of the bone/screw interface occurs, placement of a wider and/or longer screw is advised, within anatomical limitations. If screw replacement fails to establish adequate strength, repositioning of the screw and/or extension of the construct is advised. Following screw placement, intraoperative lateral and A/P radiography must be performed to confirm appropriate positioning. 4

Step 10 The Rod Bender is used for rod contouring, if needed. Care should be taken to place rod contours between the points of rod fixation, rather than through them. Alternatively, pre-bent rods are available. CAUTION Once bent, avoid reverse bending the rod in the same location. This may result in rod weakening and premature fatigue fracture. Step 11 The Rod Gripper is used to introduce the rod into the Pedicle Screws. The rod should extend at least 5mm beyond the end screws of the construct. CAUTION Avoid placement of a bent-rod apex into the locking zone of a screw. This may result in abnormal locking torque, screw damage, or weakening of fixation. Step 12 After rod placement, the Provisional Locking Wrench is introduced into the slotted portion on the top of the screw. The Provisional Locking Wrench is used to rotate the screw heads 45 clockwise into the provisional locking position. A tactile pop will be felt when the provisional locking position is achieved. In this position, the screws can be axially compressed or distracted on the rod. The provisional locking position is functionally equivalent to a loosely threaded setscrew on a traditional pedicle screw system. Note that the Provisional Locking Wrench is not designed to rotate the screws into the final, fully locked position. 5

Step 13 In lieu of using the Provisional Locking Wrench, the Reducer Instrument can be used to perform rod reduction into the screw. Step 14 The Reducer Instrument tip is placed over the rod and screw such that the instrument tip fully engages the entire screw head. The area around the screw should be free of bony protrusion to ensure full engagement. Step 15 The Reducer Instrument pistol grip handles are squeezed to perform rod reduction. CAUTION Application of excessive force onto the Reducer Instrument can result in screw damage, instrument damage, screw pullout, pedicle fracture, and/or neurological injury. Do not exceed physiological forces in reducing the rod. If unable to reduce, consider additional rod contouring, screw relocation, or in situ fusion. 6

Step 16 Once reduction has been performed, the Final Locking Wrench can be engaged through the center of the Reducer Instrument to perform screw locking. The Final Locking Wrench can be used for either provisional locking or final locking. With the Reducer Instrument fully engaged, the Final Locking Wrench is placed such that the tip of the Final Locking Wrench engages with the slots in the Pedicle Screw head. The driver tip will be felt as it drops down into the slots. Step 17 The Distractor Instrument is used to perform screw distraction while the screw heads are in the provisional locking position. Alternatively, an individual screw can undergo final tightening (see Step 19) and be used as a fulcrum to be distracted or compressed against. Once the screws are in the desired position, the Provisional Locking Wrench is used to rotate the screw top clockwise until hand-tightening on the rod is achieved. An In-line Distractor is also available. Step 18 The Compressor Instrument is used to perform screw compression while the screw heads are in the provisional locking position. Alternatively, an individual screw can undergo final tightening (see Step 19) and be used as a fulcrum to be distracted or compressed against. Once the screws are in the desired position, the Provisional Locking Wrench is used to rotate the screw top clockwise until hand-tightening on the rod is achieved. 7

Step 19 Once satisfactory anatomical alignment has been achieved, final tightening of the screws can be performed. The Counter-torque Sleeve is placed over the screw head prior to final screw locking. Care must be taken to ensure that the instrument is FULLY SEATED over the screw and rod prior to introduction of the Final Locking Driver. Step 20 The Counter-torque Sleeve with the Final Locking Driver in place. 8

Step 21 With the Counter-torque Sleeve fully engaged, the Final Locking Driver is placed such that the tip of the Final Locking Driver engages with the slots in the Pedicle Screw head. The driver tip will be felt as it drops down into the slots. Step 22 The Final Locking Driver is rotated clockwise. Slight downward pressure should be placed on the Final Locking Driver during tightening to maintain engagement. At the final locking position, the Final Locking Driver will reach the lock indicator line. The top of the screw is visually inspected to confirm full rotation. At this point, Driver and Sleeve are removed. 9

Method for Reduction of Spondylolisthesis Step 23 A Persuader Instrument is provided to perform reduction of spondylolisthesis if required. The jaws of the Persuader Instrument can be introduced under the polyaxial screw top from either a medial or lateral approach with the screw in the fully unlocked position. Step 24 The handle of the Persuader Instrument is then rotated clockwise to reduce the rod into the screw. Once the rod has been reduced into the screw, an additional 45 degrees of rotation is placed upon the handle to rotate the screw into the provisional locking position. At this point the Persuader Instrument can be removed and the rod will be loosely captured in the screw for further compression or distraction, if required prior to final locking. CAUTION Application of excessive torque onto the Persuader Instrument can result in screw damage, instrument damage, screw pullout, pedicle fracture, and/or neurological injury. Do not exceed physiological forces in reducing spondylolisthesis. If unable to reduce, consider additional rod contouring, screw relocation, or in situ fusion. Step 25 A Rod Fork is provided to reduce the rod in place if required. The Rod Fork jaws engage the screw and the Rod Fork is rocked to achieve rod reduction. 10

Cross Connector Placement (if required) Cross Connectors are available in both fixed and variable configurations. Prior to placement of a Cross Connector, the appropriate size can be determined by using the Cross Bar Sizing Template. Once the correct size has been determined, the Cross Bar is placed spanning the rods bilaterally. The threaded portion of each Cross Bar contains a deformable ring which contacts the bottom surface of the rod. The Cross Bar is placed over the rods such that each rod is fully engaged in the Cross Connector jaws. The Cross Bar Hex Fasteners are tightened using the Cross-Connector Driver and Cross-Connector Torque Handle. The Cross Bar Hex Driver is placed through the Cross-Connector Countertorque Instrument, which engages the Cross Connector body. When the pre-set tightening torque is achieved, a clicking sound will be heard and the handle will no longer transmit torque. Removal of the Cross Bar is achieved by reversing the procedure. System Removal/Revision If a rod needs to be removed or re-positioned, the Counter-torque Sleeve is introduced over the screw and rod. The Final Locking Driver is introduced into the sleeve such that its tip engages the screw top. The Final Locking Driver is then rotated counterclockwise until its locking tip is parallel to the rod. Slight downward pressure should be placed on the Final Locking Driver during loosening to maintain engagement. The rod can then be removed or repositioned. It is advised that a screw undergo no more than two locking cycles. If additional cycles are required, then the screw should be replaced with a new one. The screw is removed using the Locking Pedicle Screwdriver and Ratcheting Handle. If a screw is replaced, it is recommended that a larger screw be placed to maintain bony purchase, provided that the larger screw size is within anatomical limitations. 11

X90 Pedicle Screw System Instruments Pedicle Screw Driver with Ratcheting Handle #N600001550/N60000473 Rod Persuader #N60000500 Pedicle Screw Tap with Ratcheting Handle 4.75mm #X010-0550 5.5mm #X010-0551 6.5mm #X010-0552 7.5mm #X010-0553 8.25mm #X010-0554 Provisional Locking Wrench #N60001553 Cross Bar Screwdriver with Torque Handle #N60000496/478 Counter-torque Locking Sleeve #N60000513 Counter-torque Instrument for Cross Bar Screwdriver #N60000494 Final Locking Driver #N60000515 Reducer #N60001540 Final Locking Wrench #N60001554 12

Curved Pedicle Probe #N60000464 Compressor #N60000485 Straight Pedicle Probe #N60000463 Rod Bender #N60000481 Bone Awl #N60000461 Rod Fork #N60001530 Cross Bar Sizing Template #N60000497 Curved Sounding Probe #N60000471 Straight Sounding Probe #N60000470 In-line Distractor #X010-0166 Rod Holder #X010-0168 Distractor #N60000483 13

WARNING: In the USA, this product has labeling limitations. See package insert for complete information. CAUTION: USA Law restricts these devices to sale by or on the order of a physician. X-spine the X-spine logo and X90 are trademarks of X-spine Systems, Inc. Products Patented and Patents Pending. All products are not currently available in all markets. 2012 X-spine Systems, Inc., All rights reserved. F-1000.10 Rev B 9565 2M 6/12 I2M/CI EC 60-1211 X-spine Systems, Inc. 452 Alexandersville Rd., Miamisburg, OH 45342 Phone: 800-903-0640 Direct: 937-847-8400 Fax: 937-847-8410 www.x-spine.com