SODIUM/NA. See below for information on factors affecting results. Certain substances, such as drugs, may affect analyte levels in vivo.

Similar documents
POTASSIUM/K. 3.6 mmol/l

CHLORIDE / CL. Expected Values Reportable Reference Test/Abbreviation Units* Range Range 3 Chloride/CL mmol/l (meq/l)

CREATININE/CREA O 2. O Glycine + Formaldehyde + H 2

LACTATE/LAC. Pyruvate + H 2

CREATINE KINASE MB/ (CK-MB)

GLUH PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

INSTRUCTIONS FOR USE Cl -

For In Vitro Diagnostic Use

CARDIAC TROPONIN I/ (ctni)

INSTRUCTIONS FOR USE

ICT (Na +, K +, Cl ) Sample Diluent

WATER, SODIUM AND POTASSIUM

The Virtues and Pitfalls of Implementing a New Test

FreeStyle Lite A Blood Glucose Meter That Requires No Coding

I. Subject: Ionized Calcium (Ca++) Analysis Whole Blood

Diagnostic reagent for quantitative in vitro determination of Urea / Blood Urea Nitrogen in serum, plasma and urine by colorimetry.

INSTRUCTIONS FOR USE

i-stat Alinity v Utilization Guide

USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

For In Vitro Diagnostic Use. Rx Only. Reviewed by Date Reviewed by Date

i-stat Alinity v Utilization Guide

INSTRUCTIONS FOR USE Na +

(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%)

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY ONLY TEMPLATE

White Paper, Evaluation of WaveSense JAZZ Blood Glucose Monitoring System Analytical Performance to EN ISO 15197:2015 Standard

IDEXX Catalyst One Chemistry Analyzer for In-house Measurement of Total Thyroxine (TT 4 ) Concentration in Serum from Dogs and Cats

Performance Characteristics of a New Single-Sample Freezing Point Depression Osmometer

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

INSTRUCTIONS FOR USE

Patient: 55 y female (ambulatory)

Applicable To Employees of Gundersen Boscobel Area Hospital laboratory and Gundersen Palmer Lutheran Hospital and Clinic Laboratories.

Determination of hemoglobin is one of the most commonly

Blood Gases 2: Acid-Base and Electrolytes Made Simple. Objectives. Important Fact #1

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

ASSESSMENT OF A POINT-OF-CARE DEVICE FOR MEASURING CREATININE IN A COMMUNITY SCREENING PROGRAM FOR CHRONIC KIDNEY DISEASE

Date. Measurements of cocaine and cocaine metabolites are used in the diagnosis and treatment of cocaine use or overdose.

In Vitro Diagnostic Glucose Test System

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Glucose Analytical Comparability Evaluation of the YSI 2300 STAT Plus and YSI 2900D Biochemistry Analyzers

Performance Characteristics of Eight Estradiol Immunoassays

SCIEX Vitamin D 200M Assay for the Topaz System

1. PROTOCOL. Comparison Study Summary. Tuality Healthcare 324 SE 9 th Ave. Suite E Hillsboro, OR July 30, 2014

GB/T Translated English of Chinese Standard: GB/T

Chapter 2. High-sensitivity C-reactive protein methods examined

METHOD VALIDATION CASE

Basic Fluid and Electrolytes

Creatinine Test Code: CRE

System accuracy evaluation of FORA Test N Go Blood Glucose Monitoring System versus YSI 2300 STAT Plus glucose analyzer following ISO 15197:2013

G. Snodgrass, K. Ackles, A. Blanco and A. Versaggi Ortho Clinical Diagnostics, Rochester, NY 14626

System accuracy evaluation of FORA Test N Go Blood Glucose Monitoring System versus YSI 2300 STAT Plus glucose analyzer following ISO 15197:2013

Aina Blood Monitoring System

HbA1c3 PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems.

PHSA Laboratories CW Site - Point of Care Title: CWPC_BGE_0105 istat1 Quick Reference Guide

C30-A2 ISBN ISSN Point-of-Care Blood Glucose Testing in Acute and Chronic Care Facilities; Approved Guideline Second Edition

RENAL TUBULAR ACIDOSIS An Overview

There are number of parameters which are measured: ph Oxygen (O 2 ) Carbon Dioxide (CO 2 ) Bicarbonate (HCO 3 -) AaDO 2 O 2 Content O 2 Saturation

Determination of Ethanol in Breath and Estimation of Blood Alcohol Concentration with Alcolmeter S-D2

PRINCIPLE REF ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Phosphorus Test Code: PHOS

Clinical Chemistry

Written By: Joann O Connor Date: 03/05/2017 Effective Date: 03/28/2017 1

Comparison of Three Whole Blood Creatinine Methods for Estimation of Glomerular Filtration Rate Before Radiographic Contrast Administration

Stability of prothrombin time and activated partial thromboplastin time tests under different storage conditions

HbA1c PRINCIPLE REF ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Acid Base Balance. Professor Dr. Raid M. H. Al-Salih. Clinical Chemistry Professor Dr. Raid M. H. Al-Salih

GlucoMen LX PLUS blood glucose and blood ketone meter. Accuracy Evaluation to New ISO 15197:2013, with Technical and Specification Data

C RITICAL C ARE. Davide Colombo Kevin Flanagan Kevin Fallon. The IL Glucose Biosensor: Interfering Substance Studies.

BÜHLMANN fcal turbo. Calprotectin turbidimetric assay for professional use. Reagent Kit B-KCAL-RSET. Revision date:

Analytical and Clinical Performance of the epoc Blood Analysis System. Experience at a Large Tertiary Academic Medical Center

OP2 PRINCIPLE REF ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

METHOD VALIDATION: WHY, HOW AND WHEN?

HbA1c enzymatic assay evaluation at AN academic

i-stat CHEM8 + Cartridge Quick Reference Guide

Cell Culture Monitoring with the Vi-CELL MetaFLEX

INSTRUCTIONS FOR USE

Clinical interpretation of the plasma sodium concentration: a volume-tonicity chart

Standard Operating Procedure

Method Comparison Report Semi-Annual 1/5/2018

OraSure Technologies, Inc Eaton Avenue, Bethlehem, PA Phone: (610) (USA) Fax: (610)

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

A150 Product Number 31150

METHOD VALIDATION CASE

Seeing is not Believing (13-Nov-2004)

Aspartate Aminotransferase Test Code: AST

Bern Harrison, B.A., Cheryl Leazenby, B.S., and Solveig Halldorsdottir, Ph.D.

Original Article Interfering effect of bilirubin on the determination of alkaline phosphatase

Clinical Chemistry (CHE 221)

Author. Introduction. Abstract

Total Thyroxine ELISA (T4)

Relationship between glucose meter error and glycemic control efficacy

IDEXX Catalyst SDMA Test for in-house measurement of SDMA concentration in serum from dogs and cats

Calcium (Ca 2+ ) mg/dl

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems and the AEROSET System.

METHOD 9079 SCREENING TEST METHOD FOR POLYCHLORINATED BIPHENYLS IN TRANSFORMER OIL

References Required document for Laboratory Accreditation by the College of American Pathologists.

UREA CE Insert. 01 English - Ref.: 27. Ref.:27

C RITICAL C ARE 2. Angelo Manzoni, Susanna Zanardi, Pietro Zonca Jay Johnson. Glucose biosensor for whole blood analysis

Recent Advances in the Analysis of Ethanol in Saliva: Evaluation of the QED Device

Transcription:

SODIUM/NA Sodium is measured by ion-selective electrode potentiometry. In the calculation of results for sodium, concentration is related to potential through the Nernst equation. The i-stat System uses direct (undiluted) electrochemical methods. Values obtained by direct methods may differ from those obtained by indirect (diluted) methods. 1 See below for information on factors affecting results. Certain substances, such as drugs, may affect analyte levels in vivo. 2 If results appear inconsistent with the clinical assessment, the patient sample should be retested using another cartridge. Intended Use The test for sodium, as part of the i-stat System, is intended for use in the in vitro quantification of sodium in arterial, venous, or capillary whole blood. Sodium measurements are used for monitoring electrolyte imbalances. Contents Each i-stat cartridge contains one reference electrode (when potentiometric sensors are included in the cartridge configuration), sensors for the measurement of specific analytes and a buffered aqueous calibrant solution that contains known concentrations of analytes and preservatives. For cartridges that contain a sensor for the measurement of sodium, a list of reactive ingredients is indicated below: Reactive Ingredient Sodium (Na + ) Minimum Quantity 121 mmol/l Metrological Traceability The i-stat System test for sodium measures sodium amount-of-substance concentration in the plasma fraction of arterial, venous, or capillary whole blood (dimension mmol L -1 ) for in vitro diagnostic use. Sodium values assigned to i-stat s controls and calibration verification materials are traceable to the U.S. National Institute of Standards and Technology (NIST) standard reference material SRM956. i-stat System controls and calibration verification materials are validated for use only with the i-stat System and assigned values may not be commutable with other methods. Further information regarding metrological traceability is available from Abbott Point of Care Inc. Expected Values Reportable Reference Test/Abbreviation Units* Range Range 3 Sodium/Na mmol/l (meq/l) 100 180 138 146 *The i-stat System can be configured with the preferred units. Rev. Date: 15-Jul-16 Art: 714173-00P

The i-stat reference range for whole blood listed above is similar to reference ranges derived from serum or plasma measurements with standard laboratory methods. The reference range programmed into the analyzer and shown above is intended to be used as a guide for the interpretation of results. Since reference ranges may vary with demographic factors such as age, gender and heritage, it is recommended that reference ranges be determined for the population being tested. Clinical Significance Tests for sodium in the blood are important in the diagnosis and treatment of patients suffering from hypertension, renal failure or impairment, cardiac distress, disorientation, dehydration, nausea and diarrhea. Some causes of increased values for sodium include dehydration, diabetes insipidus, salt poisoning, skin losses, hyperaldosteronism and CNS disorders. Some causes for decreased values for sodium include dilutional hypona tremia (cirrhosis), depletional hyponatremia and syndrome of inappropriate ADH. Performance Characteristics The typical performance data summarized below was collected in health care facilities by health care professionals trained in the use of the i-stat System and comparative methods. Precision data were collected in multiple sites as follows: Duplicates of each control fluid were tested in the morning and in the afternoon on five days for a total of 20 replicates. The averaged statistics are presented below. Method comparison data were collected using CLSI guideline EP9-A 4. Venous blood samples were collected in lithium heparin Vacutainer tubes and analyzed in duplicate on the i-stat System. A portion of the specimen was centri fuged and the separated plasma was analyzed in duplicate on comparative methods within 20 minutes of collection. Deming regression analysis 5 was performed on the first replicate of each sample. In the method comparison table, n is the number of specimens in the data set, Sxx and Syy refer to estimates of imprecision based on the duplicates of the comparative and the i-stat methods respectively, Sy.x is the standard error of the estimate, and r is the correlation coefficient.* Method comparisons will vary from site to site due to differences in sample handling, comparative method calibration and other site specific variables. *The usual warning relating to the use of regression analysis is summarized here as a reminder. For any analyte, if the data are collected over a narrow range, the estimate of the regression parameters is relatively imprecise and may be biased. Therefore, predictions made from these estimates may be invalid. 4 The correlation coefficient, r, can be used as a guide to assess the adequacy of the comparative method range in overcoming this problem. As a guide, the range of data can be considered adequate for r >0.975. Precision Data (mmol/l or meq/l) Aqueous Control Mean SD %CV Level 1 120.0 0.46 0.4 Level 3 160.0 0.53 0.3 Method Comparison (mmol/l or meq/l) Beckman Nova Synchron Kodak STAT CX 3 Ektachem 700 Profile 5 n 189 142 192 Sxx 0.74 0.52 0.54 Syy 0.53 0.58 0.53 NA - 2 Art: 714173-00P Rev. Date: 15-Jul-16

Slope 1.00 0.98 0.95 Int t -0.11 3.57 5.26 Sy.x 1.17 1.04 1.53 Xmin 126 120 124 Xmax 148 148 148 r 0.865 0.937 0.838 Cartridge Comparison The performance characteristics of the sensors are equivalent in all cartridge configurations. System difference analysis was performed on 40 patient samples using the i-stat 6+ and i-stat EC4+ cartridges. In the 130 150 mmol/l range the average difference was 0.750. Factors Affecting Results* Sodium heparin may increase sodium results up to 1 mmol/l 6. Hemodilution of the plasma by more than 20% associated with priming cardiopulmonary bypass pumps, plasma volume expansion or other fluid administration therapies using certain solutions may cause clinically significant error on sodium, chloride, ionized calcium and ph results. These errors are associated with solutions that do not match the ionic characteristics of plasma. To minimize these errors when hemodiluting by more than 20%, use physiologically balanced multi-electrolyte solutions containing low-mobility anions (e.g., gluconate). Interference studies were based on CLSI guideline EP7-A2 7. Test concentrations used were as per the CLSI guideline unless otherwise indicated. When added to a plasma pool the following substances (at the concentrations indicated) were found to interfere with the i-stat sodium assay: Substance Test Concentration (mmol/l) Bromide 37.5 Interference Use another method. See Note 1 below. Nithiodote (sodium thiosulfate) 16.7 12 Increased i-stat Sodium results. See Note 2 below. The following substances are known not to significantly interfere with the i STAT sodium assay at the stated test concentrations: Substance Test Concentration (mmol/l) Acetaminophen 1.32 Acetylcysteine 10.2 Ascorbate 0.34 Bromide (therapeutic) 2.5 8,9,10 β-hydroxybutyrate 6.0 11 Lactate 6.6 Magnesium Chloride 1.0 Salicylate 4.34 Rev. Date: 15-Jul-16 Art: 714173-00P NA - 3

Note: 1) Bromide has been tested at two levels: the CLSI recommended level and a therapeutic plasma concentration level of 2.5 mmol/l. The latter is the peak plasma concentration associated with halothane anesthesia, in which bromide is released. APOC has not identified a therapeutic condition that would lead to levels consistent with the CLSI recommended level. Bromide at a concentration of 37.5 mmol/l increased i-stat sodium results, while a therapeutic range of bromide (2.5 mmol/l) did not significantly interfere with i-stat sodium results. 2) Nithiodote (sodium thiosulfate) is indicated for the treatment of acute cyanide poisoning. The journal article titled Falsely increased chloride and missed anion gap elevation during treatment with sodium thiosulfate indicated that sodium thiosulfate could be used in the treatment of calciphylaxis indicating that the highest concentration likely to be seen in plasma [is] after infusion of a 12.5 g dose of sodium thiosulfate pentahydrate. Assuming that the 12.5 g dose of sodium thiosulfate pentahydrate is distributed in a typical blood volume of 5 L with a hematocrit of 40%, the peak sodium thiosulfate plasma concentration expected is 16.7 mmol/l. 12 *It is possible that other interfering substances may be encountered. The degree of interference at concentrations other than those listed might not be predictable. NA - 4 Art: 714173-00P Rev. Date: 15-Jul-16

References 1. N.W. Tietz, E.L. Pruden, O. Siggaard-Andersen, Electrolytes in Tietz Textbook of Clinical Chemistry Second Edition, C.A. Burtis and E.R. Ashwood, eds. (Philadelphia: W.B. Saunders Company, 1994). 2. D.S. Young, Effects of Drugs on Clinical Laboratory Tests, 3rd ed. (Washington, DC: American Association of Clinical Chemistry, 1990). 3. B.E. Statland, Clinical Decision Levels for Lab Tests (Oradell, NJ: Medical Economic Books, 1987). 4. CLSI. Method Comparison and Bias Estimation Using Patient Samples; Approved Guideline. NCCLS document EP9-A [ISBN 1-56238-283-7]. CLSI, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898, USA 1995. 5. P.J. Cornbleet and N. Gochman, Incorrect Least-Squares Regression Coefficients in Method- Comparison Analysis, Clinical Chemistry 25:3, 432 (1979). 6. Tips on Specimen Collection. Vol 1. Monograph of Medical Laboratory Observer's "Tips from the Clinical Experts", published by Medical Economics in collaboration with Becton, Dickinson and Company. Mark Zacharia, ed. Montvale NJ; 1997:26. 7. Clinical and Laboratory Standards Institute (CLSI). Interference Testing in Clinical Chemistry; Approved Guideline-Second Edition. CLSI document EP7-A2 (ISBN 1-56238-584-4). Clinical and Laboratory Standards Institute, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898, USA 2005. 8. Kharasch E.D., Hankins D., Mautz D., Thummel K.E.. Identification of the enzyme responsible for oxidative halothane metabolism: implications for prevention of halothane hepatitis. Lancet 1996; 347:1367-71. 9. Morrison J.E., Friesen R.H., Elevated serum bromide concentrations following repeated halothane anaesthesia in a child. Can J Asaesth 1990; 37 (7): 801-803. 10. Hankins D.C, Kharasch E.D., Determination of the halothane metabolites trifluoroacetic acid and bromide in plasma and urine by ion chromatography. J of Chromatography B. 692 (1997) 413-418. 11. Charles R.A, Bee Y.M, Eng P.H.K., Goh S.Y. Point of care blood ketone testing: screening for diabetic ketoacidosis at the emergency department. Singapore Med J 2007; 48 (11): 986. 12. Wendroth Scott M., Tiffany N. Heady, Doris M. Haverstick, Lorin M. Bachmann, Mitchell G. Scott, James C. Boyd, and David E. Bruns. Falsely increased chloride and missed anion gap elevation during treatment with sodium thiosulfate. Clinica Chimica Acta 2014; 431: 77 79. i-stat is a registered trademark of the Abbott Group of Companies in various jurisdictions. Vacutainer is a registered trademark of Becton Dickinson and Company, Franklin Lakes, NJ USA. CX 3 is a registered trademark of Beckman Coulter Incorporated, Fullerton CA USA. Ektachem was a trademark of Kodak Clinical Diagnostics. This system is now the Vitros distributed by Ortho-Clinical Diagnostics, Rochester, NY USA. Stat Profile is a registered trademark of Nova Biomedical, Waltham, MA USA. Abbott Point of Care Inc. 100 and 200 Abbott Park Road Abbott Park, IL 60064 USA Emergo Europe Molenstraat 15 2513 BH, The Hague The Netherlands 2016 Abbott Point of Care Inc. All rights reserved. Printed in USA. Rev. Date: 15-Jul-16 Art: 714173-00P NA - 5