Total Acid Number in petroleum products by automatic titration

Similar documents
ebook Best practices using automated titrators Achieving speed and accuracy in your lab

Free and Total Sulfur Dioxide (SO 2. ) in wine (Ripper method) by automatic titration

Determination of Total Hardness in Water by Automatic Titration

Determination of the total acid number in petroleum products

Thiols (mercaptans) in Fuels (ASTM D )

Determination of the total acid number in petroleum products

PtPt-electrode with temperature sensor, Intellical MTC695

Application Note. Determination of the Acid Number (TAN) Tips and Tricks

Determination of acid number in diesel engine oil

Application Note #67 Total Acid Number (TAN)

Experiment 3. Potentiometric Titration Using a ph Electrode. information necessary for both purposes by monitoring the ph of the solution as the

TRATION: ANALYSIS OF SODIUM HYDROXIDE

HI Total Alkalinity Mini Titrator for Water Analysis

Determining the Molecular Mass of an Unknown Acid by Titration

HI Total Acidity Mini Titrator for Water Analysis

HI Total Alkalinity Mini Titrator for Water Analysis

Free Chlorine. Based on 4500-Cl D. in Standard Methods for the Examination of Water and Wastewater DOC

TRATION: ANALYSIS OF SODIUM HYDROXIDE

Determination of Langelier Index in Water

Non-aqueous Phase Titration for Total Acid Number of Crude Oil

EXPERIMENT 2: ACID/BASE TITRATION. Each person will do this laboratory individually. Individual written reports are required.

Pt-electrode with temperature sensor, Intellical MTC695

COLE-PARMER LABORATORY SURFACTANT ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER REPLACEABLE MEMBRANE SCIENTIFIC SURFACTANT ION ELECTRODES INSTRUCTION MANUAL

Determination of the acid value (AV) Application Bulletin 200/3 e. Electrodes Solvotrode easyclean

White Paper. Thermometric Titration of Acid Number According to ASTM D8045

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

3 To gain experience monitoring a titration with a ph electrode and determining the equivalence point.

EasyPlus Titration. Food & Beverage Analysis Made Easy Swiss Precision for Your Analysis

Titration of Synthesized Aspirin A continuation of the aspirin synthesis lab

Water Determination in Ethanol by Karl Fischer Titration

EXPERIMENT. Titration of the Weak Acid Potassium Hydrogen Phthalate (KHP)

Biodiesel Fundamentals for High School Chemistry Classes. Laboratory 3: Determination of the Acid Number of Vegetable Oils by Titration

Hardness, Total, Sequential

Application Note No. 113/2013 Nitrogen & protein determination in dry pet food KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Lab 05 Introduction Reactions Pre Lab Problems (answer on separate paper)

Experiment: Iodometric Titration Analysis of Ascorbic Acid Chem251 modified 09/2018

Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid

Pectins. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016

6.02 Uniformity of Dosage Units

Strength of Vinegar by Acid-Base Titration

Petrolatum. Stage 4, Revision 1. Petrolatum is a purified semi solid mixture of hydrocarbons obtained from petroleum.

METTLER TOLEDO Titrators. 30 Selected Applications Application brochure 12

Experiment 6: STANDARDIZATION OF A BASE; MASS PERCENT OF AN ACID

Application Note No. 107/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Worksheet. Worksheet. Worksheet. Worksheet. Student Performance Guide. Student Performance Guide

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

STANDARD OPERATING PROCEDURE TITLE: TOTAL IGE EIA (HYTEC 288)

Acetic Acid in Vinegar by Acid/Base Titration

MitoCheck Complex II Activity Assay Kit

Standardization of a Base, Mass Percent of an Acid

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

HI FREE & TOTAL SULFUR DIOXIDE MINITITRATOR for wine analysis

Titrimetric Determination of Hypo Index, Thiosulfate, and Sulfite in EASTMAN Color Films, Process ECN-2 Fixer

Chemistry 151 Last Updated: Dec Lab 2: Measurements & Chemical Changes

» Croscarmellose Sodium is a cross linked polymer of carboxymethylcellulose sodium.

Method (6 to 1000 µg/l Chlorine as Cl 2 ) Digital Titrator

IODINE AFFINITY. 3. Extraction Shells: Paper, 80 x 22 mm (Note 1)

E55A GELATIN, GELLING GRADE Gelatina

RayBio DPP4 Inhibitor Screening Kit

Determination of Chlorine Dioxide, Chlorite and Chlorine

SpeedDigester K-436, K-439 Kjeldahl Sampler System K-370/K-371 Nitrogen and Protein Determination in Milk according to the micro-kjeldahl Method

RayBio Human Granzyme B ELISA Kit

Gas Chromatography Syringe Selection Guide

Lab #3 Potentiometric Titration of Soda Ash (after Christian, p , p ) (phenolphthalein)

Determination of Copper in Green Olives using ICP-OES

Enzyme Analysis using Tyrosinase. Evaluation copy

Hydroponics TEST KIT MODEL AM-41 CODE 5406

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents

Potentiometric determination. Application Bulletin 125/3 e. Branch General analytical laboratories; water analysis; beverages

QMS TACROLIMUS APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800

EXPERIMENT 4 DETERMINATION OF REDUCING SUGARS, TOTAL REDUCING SUGARS, SUCROSE AND STARCH

EXPERIMENT 3 ENZYMATIC QUANTITATION OF GLUCOSE

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

Human HIV (1+2) antigen&antibody ELISA Kit

Determination of total caustic, total soda and alumina in Bayer process liquors with 859 Titrotherm

Hardness by EDTA Titration

MitoCheck Complex I Activity Assay Kit

Application Note No. 112/2013 Nitrogen & urea determination in cosmetics KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Nitrogen and

ab HRV 3C Protease Inhibitor Screening Kit (Colorimetric)

Instruction Number: 5681

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Take an initial volume reading and record it in your. 11/17/2014 ChemLab - Techniques - Titration

ab HMG-CoA Reductase Activity Assay Kit (Colorimetric)

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Biochemical Analysis of Plant Enzymes

The Effect of Hydrogen Peroxide Concentration (substrate) on the Activity of the Enzyme Catalase

Determination of sodium in margarine manufacture

Reagent Set DAS ELISA, Alkaline phosphatase label SRA 22001, SRA 23203, SRA 27703, SRA & SRA ToRSV, ArMV, GFLV, AnFBV and PDV

Standard Test Method for Carbon Black Iodine Adsorption Number 1

THERMALLY OXIDIZED SOYA BEAN OIL interacted with MONO- and DIGLYCERIDES of FATTY ACIDS

2. is a set of principles intended to help sustain a habitable planet.

Midi Plant Genomic DNA Purification Kit

Relative Measurement of Zeaxanthin Stereoisomers by Chiral HPLC

AOAC Research Institute Performance Tested Methods SM Program. Measurement of Free Fatty Acids Using FASafe Standard Test Kit. Certificate Report

For in vitro Veterinary Diagnostics only. Kylt Rotavirus A. Real-Time RT-PCR Detection.

Enzyme Action: Testing Catalase Activity

Transcription:

APPLICATION NOTE Total Acid Number in petroleum products by automatic titration No. T3 Water Analysis Instruments, Thermo Fisher Scientific Key words TAN, ASTM D664, ISO 6619, oil, used oil, lubricant, lubricant degradation, acidic contamination, Orion 8172BNWP, Orion 8102BNUWP, Orion Star T910, Orion Star T940. Preprogrammed methods T3a TAN, T3b TAN blank Introduction Total Acid Number (TAN) in a petroleum product is determined using the preprogrammed methods T3a TAN and T3b TAN blank. The sample is dissolved in the prescribed solvent and is directly titrated to a preset endpoint at 11 using an alkaline titrant prepared in isopropanol. Recommended equipment Thermo Scientific Orion Star Titrator T910, or T940 All-Iin-One, or equivalent with a 20 ml burrette Thermo Scientific Orion ROSS SureFlow electrode 8172BNWP or equivalent Thermo Scientific Orion Automatic Temperature Compensation (ATC) probe Analytical balance, capable of weighing to 0.0001g 10.0 ml pipette 100 ml graduated cylinder 150 ml beakers Required reagents and solutions Purchased or prepared potassium hydroxide in isopropanol (KOH in IPA) standard titrant solution, 0.1 M (0.1N) Purchased or prepared titration solvent (50:45:5 toluene/isopropanol/water) Purchased or prepared 1-3M lithium chloride in ethanol electrolyte fill solution (8.5 g LiCl in 100 ml ethanol) Reagent Grade Water (RGW) buffers: 4, 7, and 10 Electrode storage solution Carbon dioxide adsorbent See ASTM D664 for details on preparing titrant, titration solvent, and/or electrolyte fill solution.

Optional (for standardization): Potassium hydrogen phthalate (KHP) primary acidimetric standard, solid or purchased standard solution, 0.05M. Use suitable Personal Protective Equipment (PPE) and ventilation as recommended by the Safety Data Sheets (SDS) for the chemicals utilized during this procedure. Titrator setup Connect the Orion electrode, ATC, and the stirrer probe to the titrator. If not previously done, import the T3a TAN and T3b TAN blank preprogrammed methods into the titrator from the Methods screen 1. Rinse and fill the burette with 0.1M (0.1N) KOH in IPA titrant. Fill the adsorber tube on the titrant bottle cap with carbon dioxide absorbent and plug with glass wool or cover with Parafilm perforated with a few ventilation holes. See the titrator user manual for details on setting up the titrator. If bubbles are visible in the tubing, dispense titrant (from the Burette screen) until the bubbles have been expelled. Tap the tubing to dislodge bubbles. Consider standardizing the titrant before titrating samples. See Titrant section below. T3a TAN method: Preprogrammed parameters Electrode Electrode Type Electrode Name Resolution 0.001 Buffer Group USA Titrant Titrant Name NaOH_IPA Titrant ID Conc. Input Mode Manual Entry Conc. Value 0.1M Titration Titration Technique Preset End Pt. Number of Endpoints 1 Endpoint Values 11 Display Units Titration Type Direct Blank Required Yes, fixed Result Units TAN Reaction Ratio 1 Sample Amount Variable weight Pre-dose Titrant Volume 0 ml Max total titrant volume 6 ml Titration Process Control Careful Pre-stir Duration 20 sec Stir Speed Fast Sample ID Manual T3b TAN blank method: Preprogrammed parameters Electrode Electrode Type Electrode Name Resolution 0.001 Buffer Group USA Titrant Titrant Name NaOH_IPA Titrant ID Conc Input Mode Standardization Nominal Concentration 0.1M Standardize Tech Equivalence Pt. Number of Endpoints 1 Results Units M Standardize Reaction Ratio 1 Standard Name KHP Standard Amount Variable Weight Standard Molecular Wt 204.2 Standard Purity 100% Pre-dose Titrant Volume 2 ml Max total titrant volume 8 ml Stand. Process Control Routine Pre-stir Duration 5 sec Stir Speed Medium Titration Titration Technique Preset End Pt. Number of Endpoints 1 Endpoint Values 11 Display Units Titration Type Direct Blank Required No Result Units Consumption mmol Reaction Ratio 1 Sample Amount Fixed volume, 75 ml Pre-dose Titrant Volume 0 ml Max total titrant volume 2 ml Titration Process Control Careful Pre-stir Duration 5 sec Stir Speed Fast Sample ID Manual Electrode preparation First time use: Drain the aqueous fill solution from the electrode. Rinse the inner chamber with RGW to remove all traces of salt, then rinse with ethanol. Rinse and fill the electrode with the lithium chloride in ethanol electrolyte fill solution. Store the electrode in Orion ROSS storage solution with the fill hole cover in place. Daily use: Remove electrode from storage solution. Add lithium chloride in ethanol electrolyte fill solution to the bottom of the fill hole and leave the fill hole open during testing.

Rinsing: Rinse thoroughly with IPA before titrations. Rinse thoroughly with IPA, then RGW after titrations. Between titrations soak 5 minutes in 4 solution that has been diluted 1:10 with RGW. Sample and blank preparation Sample: Weigh sample into a beaker or suitable titration vessel according to the expected acid number value and record the exact weight. See table below for guidance on suitable sample weights. Measure 75 ml of titration solvent in a graduated cylinder and add to the sample. The sample is ready to titrate. Blank: Measure 75 ml of titration solvent in a graduated cylinder and pour into a beaker or suitable titration vessel. The blank is ready to titrate. See ASTM D664 Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration for more details on sample preparation. Some samples, such as used oils, may require heating and/or straining before preparation for titration. Acid Number Accuracy of Weight of Sample Weight, g 0.05 to < 1.0 20.0 ±2.0 0.10 1.0 to < 5.0 5.0 ±0.5 0.02 5 to < 20 1.0 ±0.1 0.005 20 to < 100 0.25 ±0.02 0.001 100 to <260 0.1 ±0.01 0.0005 Blank titration 1. From the Home screen or Methods screen, select option to use a saved method, then select TAN blank. 2. At the pre-titration screen, select the Calibrate option and calibrate the electrode with 4, 7, and 10 buffers. In each buffer, stir and wait at least 2 minutes before accepting the calibration value. Slope should be 92% or better. 3. After calibration, rinse electrode, stirrer, ATC, and dispenser with RGW, then rinse well with IPA. 4. Place the electrode, stirrer, ATC, and dispenser into the prepared blank sample in the beaker. Ensure that the dispenser tip is inserted below the surface of the sample and start the titration. 5. Results are reported as mmol consumption. 6. After the titration, remove the electrode, stirrer, ATC, and dispenser from the sample. Rinse well with IPA, then rinse well with RGW, and soak 5 minutes in diluted 4 buffer (diluted 1:10 with RGW) between titrations. Sample titration 7. From the Methods screen, select option to edit the saved method TAN, indicated by the pencil icon. 8. Enter the mmol consumption value for the blank as determined above. Save the TAN method. 9. Select and start the saved method TAN. 10. If the electrode has already been calibrated during this work shift, it doesn t need to be calibrated again. Select the Titration option from the pre-titration screen and proceed to the titration. 11. Rinse the electrode, stirrer, ATC, and dispenser well with RGW, then rinse well with IPA. 12. Place the electrode, stirrer, ATC, and dispenser into the prepared sample in the beaker. Ensure that the dispenser tip is inserted below the surface of the sample and start the titration. 13. Results are reported as TAN/acid number in mg KOH/g. 14. After the titration, remove the electrode, stirrer, ATC, and dispenser from the sample. Rinse well with IPA, then rinse well with RGW, and soak 5 minutes in diluted 4 buffer between titrations. 15. For best accuracy, run a total of three cycles for each sample and report the average result.. Results TAN Blank TAN (Acid Number) TAN (Acid Number) TAN Blank Sample Titration solvent Oil Used oil Average (n = 3) 0.01062 mmol 2.304 mg KOH/g 3.466 mg KOH/g RSD Analysis Time 2.59% 4 minutes 0.26% 6 minutes 3.93% 4 minutes 2

TAN of Oil TAN of Used Oil Range This preprogrammed titration method covers a range from about 0.1 to 150 mg KOH/g, when using 0.1M (0.1 N) KOH in IPA titrant and the prescribed weight of sample. Method modifications For shorter titrations: For routine titrations with wellestablished endpoint volumes, use a pre-dose to shorten the analysis time. Edit the pre-dose in the Titration section of the method. In general, set the pre-dose at a volume that is 0.5 ml less than the expected endpoint volume. Titrant Over time, standard titrant solutions age and can change concentration. For higher accuracy, determine the exact concentration by standardizing the titrant. It is common to standardize on a weekly basis, but a daily standardization frequency, may be suitable for this titrant. 1. Standardizing the 0.1M (0.1N) KOH in IPA titrant. Choose option a (using a solid standard) or choose option b (using a standard solution). a. solid KHP standard i. Accurately weigh out about 0.10 g KHP ±0.01 g into a clean 100 or 150 ml beaker. Record the exact weight to 0.0000g. Repeat twice more for a total of three beakers of KHP. Add RGW to the 60 ml mark on each beaker and stir for about 2 minutes or so until the KHP is completely dissolved If the KHP purity is not 100%, edit the Titrant section of the TAN Blank method to enter the actual purity. ii. Select the TAN Blank preprogrammed method on the titrator. iii. At the pre-titration screen, select the Standardize option and follow the prompts to standardize the titrant. iv. The new standardized titrant concentration will automatically be saved in the TAN Blank method and used for subsequent TAN Blank titrations. Make a note of the new standardized titrant concentration value. The value will be used later to update the TAN method. v. After standardizing the titrant, run the TAN Blank method on a prepared blank to determine the daily blank. Make a note of the new daily blank value. The value will be used later to update the TAN method. vi. When finished standardizing the titrant and running the daily blank, exit the TAN Blank method. vii. Go to the Methods screen and access the TAN method. In the Titrant section, edit the titrant concentration and enter the new standardized titrant concentration value. In the Titration section, edit the blank concentration and enter the new daily blank value. viii. Save the method. Proceed with TAN sample titrations, if desired b. 0.05M KHP standard solution i. Accurately pipet 10.0 ml 0.05M KHP standard solution into a clean 100 or 150 ml beaker. Add RGW to the 60 ml mark on each beaker. ii. From the Methods screen, access the TAN Blank preprogrammed method and edit the Titrant section. Change the sample amount to fixed volume and enter a volume of 10.0 ml. Enter the standard concentration (e.g., 0.05M). Save the method. iii. Select the TAN Blank method. At the pre-titration screen, select the standardize option and follow the prompts to standardize the titrant. iv. The new standardized titrant concentration will automatically be saved and used for subsequent TAN Blank method titrations. Make a note of the new standardized titrant concentration value. The value will be used later to update the TAN method.

v. After standardizing the titrant, run the TAN Blank method on a prepared blank to determine the daily blank. Make a note of the new daily blank value. The value will be used later to update the TAN method. vi. When finished standardizing the titrant and running the daily blank, exit the TAN Blank method. vii. Go to the Methods screen and access the TAN method. In the Titrant section, edit the titrant concentration and enter the new standardized titrant concentration value. In the Titration section, edit the blank concentration and enter the new daily blank value. viii. Save the method. Proceed with TAN sample titrations, if desired. 2. Certified standardized titrant solutions a. Some customers may prefer not to standardize their titrant, instead choosing to purchase and use certified standardized titration solutions. In this case, edit the Titrant section of each method (TAN Blank and TAN) method and enter the certified concentration and titrant ID (i.e., lot number, if desired). Titrator and electrode care Refer to the titrator and electrode user manuals for details on cleaning, storage, and maintenance recommendations to keep the titrator and electrode performing well. Main points for care are summarized below. Daily Care Weekly or Biweekly Care As Needed If bubbles are visible in the titrator tubing, dispense titrant until bubbles have been expelled. Tap the tubing to dislodge bubbles. Add electrode fill solution up to the bottom of the fill hole and leave the fill hole open during measurement. Calibrate the electrode with 4, 7, and 10. If desired, measure 12.45 buffer to verify calibration. Prepare a soaking solution of 4 buffer diluted 1:10 with RGW. Rinse electrode well with IPA before each titration cycle. Rinse electrode well with IPA, then RGW after each titration cycle. Between titration cycles, soak the electrode for 5 minutes in diluted 4 buffer. Cover the fill hole and store electrode in storage solution overnight. Determine the TAN Blank value daily. Notes 1 Refer to the user manual for detailed instructions. Flush, rinse, and replace the fill solution of the electrode. Change the storage solution in the electrode storage bottle. Consider standardizing the titrant on a weekly or even a daily basis. Clean the electrode by soaking 15 minutes in a warm 1% laboratory detergent solution while stirring. Then brush gently with a soft toothbrush only and rinse well with RGW. Flush, rinse, and replace the fill solution of the electrode after cleaning. Soak in storage solution 30 minutes or more before use. For slow or drifty electrode response, clean the electrode in warm 1% laboratory detergent, as noted in the Weekly Care section. If still slow or drifty, use Orion cleaning solution C, per instructions, or soak 30 minutes in 1M nitric acid, rinse well, then flush and replace the fill solution. Soak in storage solution 30 minutes or more before use. See the user manuals for maintenance details. The Kinetic Electrode Test described in ASTM D664 may be used to determine the performance of the electrode. If performance is not as expected, clean and perform maintenance on the electrode as described above. If precipitate forms in the burette, empty the burette and flush with warm tap water until dissolved. Then flush the burrette multiple times with fresh titrant. 2 With a suitable pre-dose, as described in the Method Modifications section. Without a pre-dose, titration time is 17 minutes.

To purchase Thermo Scientific laboratory products, please contact your local equipment distributor and reference the part numbers listed below: Product Description Cat. No. Titrator kits Titrators Electrodes Accessories Buffers Orion Star T910 titrator Sure-Flow kit with 8172BNWP ROSS Sure-Flow electrode and ATC probe Orion Star T940 All-in-One Titrator Sure-Flow kit with 8172BNWP ROSS Sure- Flow electrode and ATC probe Thermo Scientific Orion Star T910 Titrator without electrode Thermo Scientific Orion Star T9400 All-in-One Titrator without electrode Thermo Scientific Orion ROSS Sure-Flow Electrode Automatic Temperature Compensation (ATC) probe 100 or 150 ml beakers 100 ml graduated cylinder START9102 START9402 START9100 START9400 8172BNWP 927007MD Orion 4.01 buffer, NIST traceable, 475 ml 910104 Orion 7.00 buffer, NIST traceable, 475 ml 910107 Orion 10.01 buffer, NIST traceable, 475 ml 910110 Orion 12.46 buffer, NIST traceable, 475 ml 910112 Orion ROSS electrode storage solution, 475 ml 810001 Reagent Grade Water Thermo Scientific Barnstead Smart2Pure 12 UV Water Purification System 50129890* Reagents 0.1M (0.1N) Potassium Hydroxide in isopropanol standard titrant Potassium hydrogen phthalate, primary standard grade, solid or 0.05M solution Titration Solvent (50:45:5 toluene/isopropanol/water) 1-3 M Lithium chloride in ethanol electrolyte filling solution *Please contact your local Thermo Scientific representative for support on ordering the best water purification system for your application. And visit our website at www.thermofisher.com/labwater. References ASTM International. Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration (D664). West Conshohocken, PA. www.astm.org. Find out more at thermofisher.com/t900titratorseries Water and Lab Products Australia: (613) 9757-4300 In Australia: (1300) 735-295 China: (86) 21-6865-4588 Germany: (49) 6184-90-6321 India: (91) 22-6716-2261/2247 Japan: (81) 045-453-9175 North America: 1-978-232-6000 Toll Free: 1-800-225-1480 Singapore: (65) 6778-6876 2018 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. AN-TANPET-E RevA