Sinus rhythm with premature atrial beats 2 and 6 (see Lead II).

Similar documents
The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Step by step approach to EKG rhythm interpretation:

EKG Abnormalities. Adapted from:

Electrocardiography Biomedical Engineering Kaj-Åge Henneberg

The Electrocardiogram

Practice Questions.

2017 BDKA Review. Regularity Rate P waves PRI QRS Interpretation. Regularity Rate P waves PRI QRS Interpretation 1/1/2017

Electrocardiography Abnormalities (Arrhythmias) 7. Faisal I. Mohammed, MD, PhD

-RHYTHM PRACTICE- By Dr.moanes Msc.cardiology Assistant Lecturer of Cardiology Al Azhar University. OBHG Education Subcommittee

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

EKG Competency for Agency

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

ECG ABNORMALITIES D R. T AM A R A AL Q U D AH

Basic EKG Interpretation. Nirja Parikh, PT, DPT

TEST BANK FOR ECGS MADE EASY 5TH EDITION BY AEHLERT

Electrocardiography for Healthcare Professionals

Timing cycles. Objectives Upon completion of this program the participant will be able to:

Cardiac arrhythmias. Janusz Witowski. Department of Pathophysiology Poznan University of Medical Sciences. J. Witowski

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

CRC 431 ECG Basics. Bill Pruitt, MBA, RRT, CPFT, AE-C

THE CARDIOVASCULAR SYSTEM. Heart 2

Pacing Lead Implant Testing. Document Identifier

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital

Chapter 20 (2) The Heart

Rhythmical Excitation of the Heart

UNDERSTANDING YOUR ECG: A REVIEW

Is This Thing Working?

Rate: The atrial and ventricular rates are equal; heart rate is greater than 100 bpm (usually between bpm).

Outline. Electrical Activity of the Human Heart. What is the Heart? The Heart as a Pump. Anatomy of the Heart. The Hard Work

Biomedical Instrumentation

Cardiac Arrhythmias in Sleep

Contents. Example: Pacemaker in DDD Mode. I. Introduction II. Website and Relevant Documents III. Background Information IV.

Figure 2. Normal ECG tracing. Table 1.

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

Basic Dysrhythmia Interpretation

Cardiovascular System

BEDSIDE ECG INTERPRETATION

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Arrhythmia Management Joshua M. Cooper, MD, FHRS, FACC

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

Conduction System of the Heart. Faisal I. Mohammed, MD, PhD

Electrocardiography for Healthcare Professionals

8/20/2012. Learning Outcomes (Cont d)

The ECG Course. Boone County Fire Protection District EMS Education

CORONARY ARTERIES. LAD Anterior wall of the left vent Lateral wall of left vent Anterior 2/3 of interventricluar septum R & L bundle branches

Course Objectives. Proper Lead Placements. Review the ECG print paper. Review the mechanics of the Myocardium. Review basics of ECG Rhythms

Arrhythmia Study Guide 3 Junctional and Ventricular Rhythms

BIPN100 F15 Human Physiology I (Kristan) Problem set #5 p. 1

Conduction System of the Heart 4. Faisal I. Mohammed, MD, PhD

a lecture series by SWESEMJR

PART I. Disorders of the Heart Rhythm: Basic Principles

1 st Degree Block Prolonged P-R interval caused by first degree heart block (lead II)

Full file at

Cardiology Flash Cards

Clinical Data Summary: Avoid FFS Study

CORONARY ARTERIES HEART

Electrical Conduction

Intermittent episodes of paced tachycardia: what is the cause?

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Lab 16. The Cardiovascular System Heart and Blood Vessels. Laboratory Objectives

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Cardiac Telemetry Self Study: Part One Cardiovascular Review 2017 THINGS TO REMEMBER

Collin County Community College

Chapter 16: Arrhythmias and Conduction Disturbances

The conduction system

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.


Lab Activity 24 EKG. Portland Community College BI 232

1 Cardiology Acute Care Day 22 April 2013 Arrhythmia Tutorial Course Material

The Cardiovascular System

Practice Exercises for the Cardiovascular System

Lab 2. The Intrinsic Cardiac Conduction System. 1/23/2016 MDufilho 1

Cardiac Arrhythmias. Cathy Percival, RN, FALU, FLMI VP, Medical Director AIG Life and Retirement Company

4/14/15 HTEC 91. Topics for Today. Guess That Rhythm. Premature Ventricular Contractions (PVCs) Ventricular Rhythms

Intraoperative and Postoperative Arrhythmias: Diagnosis and Treatment

Basic ECG Interpretation Module Notebook

Diploma in Electrocardiography

Comparison of Different ECG Signals on MATLAB

Cardiovascular System: The Heart

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Introduction. Circulation

Electrocardiography for Healthcare Professionals

Collin County Community College. ! BIOL Anatomy & Physiology! WEEK 5. The Heart

Pacemaker Concepts and Terminology*

If the P wave > 0.12 sec( 3 mm) usually in any lead. Notched P wave usually in lead I,aVl may be lead II Negative terminal portion of P wave in V1, 1

Diagnostic capabilities of the implantable therapeutic systems

Human Anatomy and Physiology II Laboratory Cardiovascular Physiology

ECG Interpretation. Introduction to Cardiac Telemetry. Michael Peters, RN, CCRN, CFRN CALSTAR Air Medical Services

Pacing Codes and Modes Concepts

QUIZ/TEST REVIEW NOTES SECTION 1 CARDIAC MYOCYTE PHYSIOLOGY [CARDIOLOGY]

The Cardiac Pacemaker Case Study and its implementation in Safety-Critical Java and Ravenscar Ada

Cardiovascular system

Understanding the 12-lead ECG, part II

Principles of Biomedical Systems & Devices. Lecture 8: Cardiovascular Dynamics Dr. Maria Tahamont

4. The two inferior chambers of the heart are known as the atria. the superior and inferior vena cava, which empty into the left atrium.

Answer: The electrical current has difficulty traveling down the normal conduction pathway.

Pediatric pacemakers & ICDs:

Transcription:

Cardiac Pacemaker

Premature Beats When one of ectopic foci becomes irritable, it may spontaneously fire, leading to one or more premature beats. Atrial and junctional foci may become irritable from excess epinephrine or norepinephrine. Ventricular focus may become irritable when they experience either hypoxemia (low oxygen) or hypokalaemia (low serum potassium).when one premature beat follows and is coupled to a sinus beat, the group of two beats is called bigeminy. When two premature beats follow the sinus beat, the group of three beats is called trigeminy. Sinus rhythm with premature atrial beats 2 and 6 (see Lead II). A premature atrial beat can be identified by the change in heart rate and P-wave shape. After that, the original heart rate continues.

Premature Beats Two junctional beats, followed by nine sinus beats and then two premature junctional beats. Ventricular bigeminy in patient with atrial fibrillation. A premature junctional beat can be identified by the change in heart rate and the lack of an associated P wave. After that, the original heart rate continues. A premature ventricular contraction (PVC) can be identified by the change in heart rate and larger beat height and duration. A very wide ventricular complex is produced. After the PVC, a pause is observed because the SA node is not reset.

Heart Blocks Sinus block. A sick sinus (SA) node temporarily stop pacing for at least one beat, may lead to an escape beat from one of the ectopic foci. Sinus block is characterized by identical P waves before and after the pause. Sinus block printed from Rivertek RSIM-1500 Simulator

Heart Blocks First-degree (1 ) AV block. The impulse from the atria to ventricles is delayed, resulting in a longer than normal pause before ventricular stimulation(p-r interval). In 1 AV block, normal sinus rhythm is present, but the P-R interval exceeds 0.2 s 1 AV block with heart rate of 88 bpm and P-R interval of 0.28 s

Heart Blocks Second-degree (2 ) AV block, there is a periodic dropped beat. Type I (Wenckebach) 2 AV block, the P-R interval becomes progressively longer with each beat, until the AV node no longer conducts an impulse from the atria. Type I 2 AV block is caused by parasympathetic excess or by drugs that mimic these parasympathetic effects. In both cases, AV conduction is slowed. Type I 2 AV block. P-R intervals for beats 36 are 0.23, 0.33, 0.37, and 0.41 s.

Heart Blocks Type II (Mobitz II) 2 AV block, the P-R interval remains consistent, but a QRS complex does not follow every P wave. Two to four P waves may occur before ventricular. depolarization and a QRS complex are observed. The number of P waves and resulting conduction ratio of P waves to QRS complex relate to the increasing severity of the block. Type II 2 AV block, with a 2:1 conduction ratio.

Heart Blocks Ventricular third-degree AV block, or complete AV block, The atrial rate becomes completely dissociated from the ventricular rate, or R-R interval. No atria signal reaches the ventricles; so an ectopic focus below the block escapes overdrive suppression. If R-R interval is 40-60 bpm, then the AV junctional focus is pacing. If the R-R interval is 20-40 bpm, the ventrical focus is pacing. When a slower ventricular rate occurs in ventricular 3 AV block, blood flow to the brain becomes inadequate, which causes the patient to lose consciousness (Stokes-Adams syndrome).

Heart Failure Heart failure: the reduced pumping capacity of the heart, may causes by bundle branch block. It is a consequence of coronary artery disease, high blood pressure, or diabetes. The body compensates by increasing sympathetic nervous stimulation. When this compensation is insufficient to balance outgoing versus returning blood flow, chronic heart failure occurs. - increased QRS duration (>0.13s) - chronic low blood pressure - resting tachycardia - left ventricle remodels : changes in sphericity, wall thinning, functional mitral regurgitation (backflow of blood through the mitral valve), and increased wall stress

Heart Failure

Heart Failure Left BBB, with QRS duration of 0.16 s and two R peaks visible in V4 and V5.

Heart Failure Right BBB, with QRS duration of 0.15 s and two R peaks visible in V1

Pacemakers Direct electrical stimulation of the ventricle may act as therapy to elicit ventricle contraction. The earliest implantable pacemakers were designed to control the Stokes-Adams syndrome. Sensor-based enhancements, which include an accelerometer, can detect motion and cause the heart rate to be adjusted during physical activity. Other optional sensors can detect respiration, the presence of thoracic fluid, or pressure.

Leads Outer jacket: polyurethane or a polyurethane hybrid, silicone rubber or polyurethane insulation. Conductor: one or two metal coils of titanium or platinum/iridium that terminate as textured-surface electrodes unipolar lead administers a voltage between one electrode as the catheter and a portion of the pulse generator can as the anode. bipolar lead administers a voltage between a so-called tip electrode (cathode) and a ring electrode (anode), spaced about 10-30 mm apart at the end of the lead.

Leads a bipolar lead positioned in the atrium records the atrial P wave with greater amplitude than a far field R wave from the ventricles a unipolar lead positioned in the atrium may record a far-field R wave of greater amplitude than the atrial P wave

Leads To minimize impedance increase, cause by scar tissue development, steroid-eluting electrodes have been developed. In an early design, each electrode consists of a silicone core, impregnated with a small dose of dexamethasone sodium phosphate, in contact with porous titanium, coated with platinum (Stokes, 1987). The mechanism by which dexamethasone sodium phosphate prevents an impedance increase is not fully understood..

Pulse Generator Pulse generator is sealed titanium can containing a battery and circuitry. It is implanted in a small-incision, subcutaneous pocket in the pectoralis fascia below the clavicle, on the patient s nondominant side.

Capture Tests For these pulses to be therapeutic, the voltage must be sufficient to capture the heart, that is, to generate depolarization. During implantation, a capture test is conducted for each lead. For each test, assuming a constant preselected pulse width, the pulse amplitude voltage is decreased from a maximum setting to the point at which depolarization no longer occurs. The last pulse amplitude of capture is known as the capture threshold. Typically, the pacing threshold is then set at twice the capture threshold. An empirical applied current density adequate for stimulation is 5.0 ma/cm² which, assuming a tissue resistivity of 500 Ωcm, gives an applied field of 2.5 V/cm Electrogram from two patients, measured from tip of a pacemaker lead placed at right ventricle apex, referenced to the can. These patients were at high risk for acute coronary syndromes

Pacemaker Sensing Parameters and Modes Atrial and ventricular sensitivities: the minimum voltage thresholds for sensing a P wave and R wave, respectively. These waves are sensed from the bandpass-filtered electrogram. AV delay: the time interval after an atrial pacing pulse at A, during which an R wave may be detected. If an R wave is not detected, a ventricular pulse, V, is fired. PV delay: the time interval after a P wave, during which an R wave may be detected. If an R wave is not detected, a ventricular pulse is fired. PVARP: the time interval after R wave or ventricular stimulus, which atrial sensing is disabled. PVARP prevents retrograde P waves (which often occur following paced beats) from being sensed by the atrial amplifier and causing a pacemaker mediated tachycardia. ventricular refractory period (VRP): the time after R wave or ventricular stimulus, which ventricular sensing is disabled. VRP prevents T waves from being sensed by the ventricular amplifier.

Revised NBG Pacemaker Code (Bernstein et al., 2002) Position I II III IV V Category Chamber(s) paced Chamber(s) sensed Response to sensing Rate Modulation Multiside O = None O = None O = None O = None O = None A = Atrium A = Atrium T = Trigger R = Rate Modulation V = Ventricle V = I = Inhibited Ventricle D = Dual (A+V) D = Dual (A+V) D = Dual (T+I) A = Atrium V = Ventricle D = Dual (A+V) Rate modulation: adaptive pacing to achieve more realistic physiological behavior.

Pacemaker Modes Two pacemaker modes. A: DDDxx. Both the right atrium and right ventricle are sensed and paced. B: VVIxx. Only the right ventricle is sensed and paced. In these beats, which occur during atrial fibrillation, the first two ventricular depolarization are spontaneous (S), but the third ventricular depolarization is paced (P)

Key Features To address unknown lead failure mechanisms, leads may undergo three tests, according to British Standard EN 45502-2-1:2003 Active Implantable Medical Devices Part 2-1: Particular Requirements for Active Implantable Medical Devices Intended to Treat Bradyarrhythmia (Cardiac Pacemakers) (BSI, 2003). Battery. A pacemaker system is only as good as its battery, which typically lasts about 7-10 years. The battery is replaced by replacing the pulse generator. Sensitivity. According to British Standard EN 45502-2-1:2003, sensitivity error must be within ±10%. Minimum Susceptibility to Electromagnetic Interference. Modern pulse generators are designed to minimize the effect of EMI radiating from 16.6 Hz, which is present on some European railways, to 3 GHz, the radiation field from cell phones. EN 45502-2- 1:2003 specifies seven tests to assess the effects of electromagnetic nonionizing radiation.

References 1. Fundamental of Anatomy and Physiology, Frederic H. Martini 2. Biomedical Instrumentation: Application and Design, John G. Webster 3. Medical Device Technologies: A Systems Based Overview Using Engineering Standards, Gail D. Baura 4. The Biomedical Engineering Handbook, Joseph D. Bronzino

clavicle