Wee-Wii-validation? Dr Lisa Bunn Plymouth University

Similar documents
A Comparison Between Methods of Measuring Postural Stability: Force Plates versus Accelerometers Abstract Introduction

Age-related effect of visual biofeedback on human balance control

Gait & Posture 31 (2010) Contents lists available at ScienceDirect. Gait & Posture. journal homepage:

ebavir, easy Balance Virtual Rehabilitation system: a study with patients

Association Degree of Physical Disability and Postural Control in Subjects with Leprosy

The validity of a portable clinical force plate in assessment of static postural control: concurrent validity study

System for Evaluation of the Static Posturography Based on Wii Balance Board

Tactile Internet and Edge Computing: Emerging Technologies for Mobile Health

Reliability and Validity of a Mobile Device Application for Use in Sports-Related Concussion Balance Assessment

Serious Games in Sport. Applications in the field of sport science

Comparison. Dynamic Gait Index (DGI)Results with. Patients with vestibular Hypofunction Youssef Koaik MPT

FAT MASS ESTIMATION BY BIOELECTRICAL IMPEDANCE ANALYSIS

Three Different Methods of Calculating Vertical Jump Height from Force Platform Data in Men and Women

Real-time Heart Monitoring and ECG Signal Processing

Movement Science Lab. Computerized Dynamic Posturography (CDP) a. Sensory Organization Test (SOT)

Effectiveness of perceptual training - proprioceptive feedback in a virtual visual diverse group of healthy subjects: a pilot study

Balance Rehabilitation Through Virtual Environments

Dr Nancy Low Choy, Bond University, Gold Coast. Paige Hooper, Physiotherapist, Bond University, Gold Coast

Equilibrioception: A Method To Evaluate The Sense Of Balance

HHS Public Access Author manuscript J Nat Sci. Author manuscript; available in PMC 2015 March 30.

The Effects of Vision and Internal and External Focus of Attention on Balance in a Yoga Pose

The reliability of a portable clinical force plate used for the assessment of static postural control: repeated measures reliability study

lntertester and lntratester Reliability of a Dynamic Balance Protocol Using the Biodex Stability System

Documentation, Codebook, and Frequencies

The Effects of Leg Spiral Kinesiology Tape Technique on Postural Sway in Clients with Multiple Sclerosis: A Quantitative Preliminary Study

Institute of Neurobiology Bulgarian Academy of Sciences. Postural and Motor Coordination during Sensory Conflict across the Life Span

MEDEIA QBIOSCAN/SODOCHECK (HW4) STEP BY STEP INSTRUCTIONS

Hemodynamic Analysis System

Instrumented Static and Dynamic Balance Assessment after Stroke Using Wii Balance Boards: Reliability and Association with Clinical Tests

Sensory Friendly Libraries: Creating an Environment for All Families. By Colleen Spano, M.S.Ed Sunshine Behavior Services, LLC

CCi-MOBILE Research Platform for Cochlear Implants and Hearing Aids HANDS-ON WORKSHOP

Image Processing Algorithms for Patient Mobility Monitoring using. Pressure Sensitive Bed and Floor Arrays

Brain Computer Interface. Mina Mikhail

IJPMR 12, April 2001; 25-30

International Journal on Bioinformatics & Biosciences (IJBB) Vol.6, No.3/4, December 2016

Autism Spectrum Disorder & Essential Classroom Strategies Presenter: Suzanne Donnelly

Created in January 2005 Duration: approx. 20 minutes

Objectives_ Series II

Faints, Fits, Funny Turns. Andrew Clements

EEG, ECG Measurement and Data Analysis. Carlo Lucignoli. ATSiP Teesside 2006

Development and Evaluation of an Objective Assessment of. Dynamic Balance Post-Stroke

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

Evaluation of the Limits of Stability (LOS) Balance Test

Healthcare Measurement of ECG and Body Temperature Signals Using Android Mobile

Low-Pressure Chromium Speciation in P2O5 using the Spectro ARCOS MV ICP and the ESI SC-DX chromfast System

BLOOD GLUCOSE LEVEL MONITORING BY NONINVASIVE METHOD USING NEAR INFRA RED SENSOR

KINETISENSE 3D CONCUSSION WHITE PAPER

Reliability and feasibility of gait initiation centre-of-pressure excursions using a Wii Balance Board in older adults at risk of falling

NeuroSky s esense Meters and Detection of Mental State

ESC-100 Introduction to Engineering Fall 2013

Biomedical Instrumentation E. Blood Pressure

Human Postural Responses to Different Frequency Vibrations of Lower Leg Muscles

Balance-Coordination-System

Natus Medical Incorporated is the sole designer, manufacturer, and seller of the following systems:

A Novel Software Solution to Diagnose the Hearing Disabilities In Human Beings

Smart NDT Tools: A New Generation of NDT Devices

ISIS IOM. System-Family. The new ISIS Xpress supplements the ISIS IOM System-Family >> APPLICATION FIELDS: >> Powerful >> User-friendly >> Flexible

Ambient Sensing Chairs for Audience Emotion Recognition by Finding Synchrony of Body Sway

THE EFFECTS OF NINTENDO WII ON THE POSTURAL CONTROL OF PATIENTS AFFECTED BY ACQUIRED BRAIN INJURY: A PILOT STUDY

Case Study. Complex Components Demand Innovative Ultrasound Solution

Postural Sway in Infants at Low and High Risk for Autism Spectrum Disorder

Various Methods To Detect Respiration Rate From ECG Using LabVIEW

week by week in the Training Calendar. Follow up graphics, sort, filter, merge, and split functions are also included.

Concepts Weight Market Size Profit Potential Technology Readiness Market Entry Difficulty

Presenter. Community Outreach Specialist Center for Sight & Hearing

Philadelphia College of Osteopathic Medicine. Samantha Snyder Philadelphia College of Osteopathic Medicine,

POWERED BY SHOW UP WITH SKYPULSE

Mechanical Vibration Causes, Effect, Analysis & Prevention Techniques

Validity of using smart phone sway balance application in measuring dynamic balance

Gait Assessment & Implications in Geriatric Rehabilitation

Blood Pressure Estimation Using Photoplethysmography (PPG)

UTILIZING TELEREHABILITATION AND VIRTUAL REALITY APPROACHES FOR MOTOR AND COGNITIVE TREATMENT THROUGH THE LIFESPAN

Neuroscience Letters

TODAY AND THE DEVELOPMENT

PROFESSIONAL FITNESS & WELLBEING CATALOGUE

STRATEGIC PLAN

Telerehabilitation.

DreamMapper 2.4. Mobile App User Guide

Development of an interactive rehabilitation game using the Nintendo WiiFit Balance Board for people with neurological injury

USING WAVELET FOR EARLY DETECTION OF PATHOLOGICAL TREMOR. Oana Geman 1, Ciprian Zamfir 2

William C Miller, PhD, FCAOT Professor Occupational Science & Occupational Therapy University of British Columbia Vancouver, BC, Canada

Intelligent Frozen Shoulder Self-Home Rehabilitation Monitoring System

A GUIDE TO SAFE MATERIAL HANDLING SAFE WORK GUIDELINES

Slide 1. Slide 2 Overview of Course. Slide 3 Overview of Course. Gait and Balance Standardized Assessment in Geriatric Fallers

Margaret Schenkman, PT, PhD, FAPTA University of Colorado, Denver Colorado

Videoconference Event ID:

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

PC based Heart Sound Monitoring System

Hand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited

Table of Contents. Introduction. 1. Diverse Weighing scale models. 2. What to look for while buying a weighing scale. 3. Digital scale buying tips

Flu season. Making the most of online appointments. August 2018

STUDY DESIGNS WHICH ONE IS BEST?

Advanced in vitro exposure systems

Stationary regime for Standing Wave Central Pattern Generator

Fall Prevention for Community Dwelling Older Adults: An Update on Assessment and Intervention Strategies

Influence of Regular Proprioceptive and Bioenergetic Physical Activities on Balance Control in Elderly Women. Vandoeuvre-lès-Nancy, France.

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

RaySafe X2 Solo DENT. X-ray meter for dental applications

Final Report. Implementation of algorithms for QRS detection from ECG signals using TMS320C6713 processor platform

Transcription:

Wee-Wii-validation? Investigating the validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance in young children Dr Lisa Bunn Plymouth University

Overview Why use a Wii balance board (WBB)? Is it valid and reliable? Is it still valid and reliable for use with children? Clinical take-home messages

Gold standard measures of postural control Sensitive Reliable Resilient setup Costly Portability Complex setup (www.kistler.com) The WiiBB - A potential tool to examine standing balance (Goble, Cone, & Fling, 2014)

WBB: An alternative measure of postural control? Cheaper Portable Easy to use Similar design 22x48 cm platform Force transducers at each corner Research to date: Adults: Clark et al., 2010 Older individuals: Scaglioni-Solano & Aragón-Vargas, 2014 Children >10 years: Larsen et al.,2014 Measuring sway: Flatters et al., 2014

How do young children differ & what difference does this make? Sensory control of balance changes during childhood Comprehension, body structure & distribution of mass alters A reduction in reliance on visual and vestibular information *Ages of 4 and 10 years (Godoi & Barela, 2008) An increase in the reliance of proprioceptive information (Shumway-Cook & Woollacott, 1985) Higher noise levels than a laboratory grade force platform Noise levels increase with lower weight (Flatters et al., 2014; Huurnink et al., 2013)

Research aim To compare the feasibility of measuring the balance abilities of typically developing children (tdc) aged 4-10 using a Wii balance board (WiiBB) To undertake measurement in a non-gait-laboratory environment in order to explore barriers and constraints to measurement To compare the accuracy and reliability of measurements to that of the gold standard force plate (Kistler)

Methods 54 tdc: 28f : 26m (school partnership in Plymouth) 40 second collections, standing still, facing forwards 4 sensory conditions: Feet together/apart, eyes open/closed (randomised) Equipment: Kistler mobile force plate with amplifier (sample rate of 200Hz) 1401 Data Acquisition hardware Laptop (OS) with Spike2 software WiiBB + Hama Nano Bluetooth USB Adapter Windows XP Laptop running Matlab v7 (sync signal)

Results: Feasibility Invited to participate n=128 Parental consent n=54 Non-return n=74 WiiBB were familiar & friendly Children were motivated-even those without parental consent! All ages followed instructions! 4 simple conditions feasible Assent gained on day n=54 Data collection (n=8 non-returnsnot tested) Parent reply slips Setup time Technical delays Data loss!!! Transducer failure 3 WiiBB Analysis not clinician friendly (Matlab, wavelet filtering ) Analysed: n=31 Data loss: n=27 (technical)

Results: Validity & reliability CoP path length (mm) 3000 EO - FA EC - FA EO - FT EC - FT Force plate Main effect of condition (ANOVA) p<0.01 ICCs good to excellent (>0.7) Force plate with WiiBB WiiBB WiiBB less sensitive to smaller fluctuations in stability (inaccuracy) Disproportionate responses to sensory conditions (may produce inaccurate Rhomberg s quotients)

Take home clinical messages Suitability of use in a clinical setting is limited Centre of pressure path length is underestimated (less sensitive appears associated with low body mass) Force transducer drop out presents an unknown bias for clinicians Significant training would be needed for clinicians to analyse data and to detect anomalies (such as force transducer drop-out, a sneeze, spikes in electrical noise) Children were keen to have their balance measured, weren t phased & were able to manage sensory tasks

Thank you & acknowledgements to the team! Dr Dorothy Cowie, Assistant Professor in the Department of Psychology Dr Dan Brady, Research Fellow in the Department of Psychology Dr Allegra Cattani, BabyLab Research Fellow in the Department of Psychology Professor Jonathan Marsden, School of Health Professions Pump-prime funding from: