Superb microvascular imaging (SMI) compared with conventional ultrasound for evaluating thyroid nodules

Similar documents
of Thyroid Lesions Comet Tail Crystals

Evolution of diagnostic ultrasound systems Current achievements in breast ultrasound

Contrast-enhanced ultrasound of solitary thyroid nodules - qualitative and quantitative evaluation: initial results

Detection of carotid plaque neovascularization with Superb Micro-Vascular Imaging

Seeing the Unseen Clinical advances and future directions of SMI

Seeing the Unseen Clinical advances and future directions of SMI

Biomedical Research 2017; 28 (21): ISSN X

Diagnostic Value of Ultrasound-detected Calcification in Thyroid Nodules

Study of validity of ultrasonographic diagnosis in relation to Fine Needle Aspiration Cytology (FNAC) diagnosis

Modern liver imaging techniques - A new era in liver ultrasound

AACE/ACE Advanced Endocrine Neck Ultrasound Training Course 2016

CLINICAL GUIDELINES. Introductory notes:

OPTO-ACOUSTIC BREAST IMAGING

Correlation CEUS & Sono Elastography for Malignant Thyroid Nodule Evaluation

Pushing the boundaries

Thyroid Nodules: US Risk Stratification. Alex Tessnow, MD, FACE, ECNU University of Texas Southwestern Associate Professor of Medicine Dallas, Texas

Warinthorn Phuttharak*, Charoonsak Somboonporn, Gatenapa Hongdomnern

Original Article Analysis of contrast-enhanced ultrasound in the differential diagnosis of papillary thyroid cancer and thyroid nodules

Quantification of solid hypo-echoic thyroid nodule enhancement with contrast-enhanced ultrasound

Can Color Doppler Sonography Aid in the Prediction of Malignancy of Thyroid Nodules?

The updated incidences and mortalities of major cancers in China, 2011

Biomedical Research 2014; 25(3): ISSN X

Differentiation of Benign and Malignant Sub-1-cm Breast Lesions Using Contrast-Enhanced Sonography

Evaluation of thyroid nodules: prediction and selection of malignant nodules for FNA (cytology)

Torsion bottle, a very simple, reliable, and cheap tool for a basic scoliosis screening

Sonographic imaging of pediatric thyroid disorders in childhood. Experiences and report in 150 cases

Comparative study on the diagnostic values of different ultrasound technologies for malignant thyroid nodules

Complementary sestamibi scintigraphy and ultrasound for primary hyperparathyroidism

Diagnostic Accuracy of Contrast-Enhanced Ultrasound Enhancement Patterns for Thyroid Nodules

OPTO-ACOUSTIC BREAST IMAGING

Korean Thyroid Imaging Reporting and Data System features of follicular thyroid adenoma and carcinoma: a single-center study

Thyroid Nodule Management

Interpreting the Thyroid Ultrasound Report

Sonographic Differentiation of Thyroid Nodules With Eggshell Calcifications

Intuitive. Intelligent. Innovative. General Imaging

Does serum CA125 have clinical value for follow-up monitoring of postoperative patients with epithelial ovarian cancer? Results of a 12-year study

Role of ultrasonography in recognition of malignant potential of thyroid nodules on the basis of their internal composition

Does elastography change the indication to biopsy? IBDC

Subdural hemorrhages in acute lymphoblastic leukemia: case report and literature review

COMPARISON OF ULTRASOUND FINDINGS WITH CYTOLOGIC RESULTS IN THYROID NODULES

Intuitive. Intelligent. Innovative. General Imaging

Ultrasound Physics & Doppler

Reevaluating the prognostic significance of male gender for papillary thyroid carcinoma and microcarcinoma: a SEER database analysis

ACRIN 6666 IM Additional Evaluation: Additional Views/Targeted US

Sonographic Features of Thyroid Nodules & Guidelines for Management

Department of Ultrasound Diagnosis, Wenzhou Central Hospital, Wenzhou, P.R. China. Abstract

THYROID NODULES: THE ROLE OF ULTRASOUND

CT findings in patients with Cabazitaxel induced pelvic pain and haematuria: a case series

Laly Jose, Sara Ammu Chacko, Simi.

A-005 US DIAGNOSIS OF NONPALPABLE BREAST LESIONS

Comparison of three mathematical prediction models in patients with a solitary pulmonary nodule

Adina Alazraki, MD, FAAP Assistant Professor Radiology and Pediatrics Emory University and Children s Healthcare of Atlanta

Real-time elastography of parotid gland masses: the value of strain ratio for the differentiation of benign from malignant tumors

Imaging Decisions Start Here SM

Up-to-date Doppler techniques for. for breast tumor vascularity: superb. microvascular imaging and contrast-enhanced ultrasound.

In adults, clinically palpable thyroid nodules are

We evaluated the medical records of 1,015 patients who underwent surgery for primary breast cancer between February 2007 and August 2008 at St.

A NEW QUANTITATIVE METHOD TO EVALUATE ADNEXAL TUMORS

Sonographic Features of Benign Thyroid Nodules

Cone-beam CT findings during prostate artery embolization for benign prostatic hyperplasia-induced lower urinary tract symptoms: a case report

Triple-negative breast cancer: which typical features can we identify on conventional and MRI imaging?

Quality Initiative Project assessing the impact of TIRADS on net number of thyroid biopsies and adherence of TIRADS-reporting by radiologists

Rates of thyroid malignancy by FNA diagnostic category

Malignant Breast Masses Pak Armed Forces Med J 2014; 64 (1): 4-8 ORIGINAL ARTICLES. Sadaf Aziz, Arfan-ul-Haq*, Asad Maqbool Ahmad

Daily inspiration. Ultrasound system HS70A SAMSUNG MEDISON CO., LTD. Scan code or visit to learn more

Thyroid Nodules: US Risk Stratification and FNA Guidelines

US LI-RADS v2017 CORE

challenge is to distinguish the few clinically significant malignant nodules from many benign ones (Table 1).

Prostate Cancer 3/15/2017. CEUS of the Prostate. The Prostate Cancer Screening Dilemma Data. Incidence: 161,360 Deaths: 26,730

Original Article Relation between qualitative and quantitative 3-dimensional ultrasound and ki-67 expression in breast cancer

Intuitive. Intelligent. Innovative. General Imaging

Thyroid and Parathyroid Ultrasound Protocol

Index terms: Thyroid Ultrasonography Pathology Cancer. DOI: /kjr

Approach to Thyroid Nodules

ArticleInfo. Spring School of Thyroidology organized by the Polish Thyroid Association 2014: abstracts of invited lectures

Long-term Follow-up for Patients with Papillary Thyroid Carcinoma Treated as Benign Nodules

.N.though. Thyroid Nodules: Evaluation with Color Doppler Ultrasonography MATERIALS AND METHODS

Dilemma in diagnosing thyroid adenoma A case report

Repeat Ultrasound-Guided Fine-Needle Aspiration for Thyroid Nodules 10 mm or Larger Can Be Performed 10.7 Months After Initial Nondiagnostic Results

Contents. Basic Ultrasound Principles and Terminology. Ultrasound Nodule Characteristics

Takashi Yagisawa 1,2*, Makiko Mieno 1,3, Norio Yoshimura 1,4, Kenji Yuzawa 1,5 and Shiro Takahara 1,6

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

ShearWave elastography in lymph nodes

Endocrine University, 2016 AACE-ACE-MAYO CLINIC

ISSN X (Print) Research Article. *Corresponding author Dr Kumud Julka

Ultrasonography of the Neck as an Adjunct to FNA. Nicole Massoll M.D.

ONCOLOGY LETTERS 14: , Yantai Hospital of Traditional Chinese Medicine, Yantai, Shandong , P.R. China

Leonard M. Glassman MD

Thyroid in a Nutshell Dublin Catherine Kirkpatrick Consultant Sonographer ULHT

Practical Approach to Thyroid Nodules:Ultrasound Criteria for Performing FNA Revisited

Su-kyoung Jeh, MD 1 So Lyung Jung, MD 2 Bum Soo Kim, MD 2 Yoen Soo Lee, MD 3

Imaging in breast cancer. Mammography and Ultrasound Donya Farrokh.MD Radiologist Mashhad University of Medical Since

Effectiveness of Superb Microvascular Imaging for the differentiation

Imaging in Pediatric Thyroid disorders: US and Radionuclide imaging. Deepa R Biyyam, MD Attending Pediatric Radiologist

Differentiated Thyroid Carcinoma

Thyroid Nodule Risk Stratification and FNA Guidelines

Combined use of AFP, CEA, CA125 and CAl9-9 improves the sensitivity for the diagnosis of gastric cancer

Downloaded from by John Hanna on 11/09/15 from IP address Copyright ARRS. For personal use only; all rights reserved

Case-based discussion:

Int J Clin Exp Med 2018;11(3): /ISSN: /IJCEM Shuhao Deng, Quan Jiang, Yicheng Zhu, Yuan Zhang

Transcription:

Lu et al. BMC Medical Imaging (2017) 17:65 DOI 10.1186/s12880-017-0241-5 RESEARCH ARTICLE Superb microvascular imaging (SMI) compared with conventional ultrasound for evaluating thyroid nodules Ruigang Lu 1, Yuxin Meng 2, Yan Zhang 1, Wei Zhao 1, Xun Wang 3, Mulan Jin 4 and Ruijun Guo 1* Open Access Abstract Background: Superb microvascular imaging (SMI) for depiction of microvascular flow in thyroid nodules was compared with color/power Doppler imaging (CDI/PDI) and contrast-enhanced ultrasonography (CEUS). In addition, the diagnostic performance of conventional ultrasound combined with SMI for differentiating benign and malignant thyroid nodules was evaluated. Methods: Preoperative conventional ultrasound consisting of gray-scale ultrasonography and CDI/PDI, followed by SMI andceus,wasusedtorecord52thyroidnodules.tworadiologists analyzed the gray-scale ultrasound signs and nodules microvascular flow patterns to differentiate between benign (n = 13) and malignant nodules (n = 39). Results: SMI was significantly more effective in the detection of microvascular flow signals than CDI/PDI. In malignant nodules, SMI depicted the presence of incomplete surrounding periphery microvasculature and of disordered heterogeneous internal microvasculature. Benign nodules showed complete surrounding periphery microvasculature (ring sign) and homogeneity internal branching. The accuracies of conventional ultrasound combined with CDI/ PDI, SMI, or CEUS for predicting malignancy were 67.31, 86.54, and 92.31%, respectively. The accuracy of SMI differed significantly from CDI/PDI (P = 0.012), but not from CEUS (P =0.339). Conclusions: Microvascular flow and vessel branching in the peripheral and internal microvasculature of thyroid nodules is depicted with greater detail and clarity with SMI compared with conventional ultrasound. SMI offers a safe and low-cost alternative to CEUS for differentiating between benign and malignant thyroid nodules. Keywords: Superb microvascular imaging, Thyroid nodule, CEUS, Microvascular, CDI/PDI, Microvessel density Background Thyroid nodules are a common finding. With development of ultrasonic technology and improvement in resolution, the rate of detection of thyroid nodules has risen, especially in younger persons [1]. In clinical practice, ultrasound is the primary imaging method for evaluating thyroid nodules. However, some of the typical characteristics of malignant nodules have a diagnostic accuracy of only 74 to 82%, including hypoechogenicity, irregular margins, being taller than wide, microcalcifications, absence of halo, and presence of perforator vessel(s) [2, 3]. None of these features is specific enough to classify a * Correspondence: Ruijunguo2016@sina.com Equal contributors 1 Department of Ultrasonography, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100020, China Full list of author information is available at the end of the article lesion as malignant, and sensitivity is also significantly lower for any single feature [4]. It is therefore important to explore a complementary method which could improve the identification of benign and malignant nodules. It is well known that blood vessels are important to the growth of a nodule, but conventional color or power Doppler imaging (CDI and PDI, respectively) are not very sensitive to microvascularity patterns and low blood flow velocity [5]. Vessel extraction methods, such as minimal path techniques to effectively locate tiny vessels, might be of help to extract vessel-related information for further diagnosis [6], although they are limited by some inherent problems like endpoint, shortcut and accumulation issues [7]. A recent improved means of visualizing low flow in microvessels is superb microvascular imaging (SMI) ultrasound technology, implemented with the Aplio 500 US The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Lu et al. BMC Medical Imaging (2017) 17:65 Page 2 of 6 system by Toshiba (Toshiba Medical Systems, Tokyo, Japan). SMI uses advanced clutter suppression to extract flow signals from large to small vessels, and depicts this information at high frame rates as a color overlay image or as a grayscale map of flow (color or monochrome SMI, respectively). The present study compares the flow imaging abilities of SMI, CDI/PDI, and CEUS for depicting microvascular flow in thyroid nodules, and evaluates the efficacy of these methods for identifying benign and malignant thyroid nodules. Methods The study was conducted from March to November 2016. Fifty prospective patients (45 women and 5 men; 52 tumors) who were referred for surgery due to suspicion of malignancy after gray-scale ultrasound or palpation, were enrolled. The mean age of these patients was 47 years (range: 20-65 years). All patients enrolled underwent ultrasound examination of the thyroid consisting of the following modalities: gray-scale ultrasound; CDI; PDI; color and monochrome SMI; and CEUS using an Aplio 500 ultrasound system with a broad bandwidth linear array transducer (imaging frequency, 14 MHz). The nodules studied were solid or cystic solid with a solid component greater than 50% and a maximum diameter of 0.5-3.0 cm. For all subjects, the settings for cross section, constant color sampling frame size, and moderation scale were identical throughout the imaging portion of the study. In selected patients, pulsed Doppler was also used during monochrome SMI to examine a few specific microvessels inside the nodule, to verify that the observed vessels were real microvasculature. Two senior radiologists read all the fixed and dynamic pictures independently. Nodules were scored by analyzing microvasculature and branching using a visual-analog scale of 0 (worst) to 10 (best), based on the semiquantitative percentage of nodule volume occupied by vessel signals. For each patient, the following characteristics were recorded: vessel branching detail, peripheral vascularization surrounding the nodule, and homogeneous or heterogeneous disordered distribution of internal small branching microvasculature. Images and cine loops of the thyroid nodules from all 5 modalities, acquired during the ultrasound examinations, were independently analyzed by 2 radiologists (blinded to the histology pathology results). The observers independently scored the digital clips from each of the 5 flow modes, and each nodule with regard to overall flow detection and vessel branching details, scoring them as 0 (worst) to 10 (best). The qualitative scores (i.e., for overall flow detection and vessel branching details) were compared on a per nodule basis using a nonparametric Wilcoxon signed rank test. All tests were performed using Stata 12.0 software (Stata Corp, College Station, TX), with P < 0.05 indicating statistical significance. To assess the consistency of the vascularity scores determined by the 2 observers, k- coefficients were calculated. Results For the 52 solid nodules, the results of histology yielded 39 malignant (papillary thyroid carcinoma) and 13 benign nodules. The latter consisted of 5 follicular adenomas, 6 nodular goiters, 1 parathyroid adenoma, and 1 shrinking cyst. The details of microvasculature within the nodules were recorded semi-quantitatively (Fig. 1). Both color and monochrome SMI delivered clearer and more cohesive vessel branching detail in the nodules compared with CDI/PDI. In malignant nodules, SMI revealed disordered heterogeneous internal microvessel distribution, scarce vascularity in hypoechoic nodules or interrupted surrounding peripheral microvasculature (Figs. 2 and 4). In benign nodules, SMI showed complete surrounding periphery microvasculature and homogeneous internal microvessel distributions (Figs. 3 and 4). The characteristics of the nodules according to microvascular flow of CDI/ PDI, SMI, and CEUS were evaluated and the accuracy of the 3 imaging microvascular flow patterns was assessed. Pulsed Doppler guided by monochrome SMI established that the small branching microvessels detected by monochrome SMI are real and can be measured (Figs. 2e, 3e and 4e). CEUS features of the nodule (Figs. 2f, 3f and 4f). Observations included heterogeneous hypoechoic enhancement of the middle nodule, and homogeneous hyperechoic enhancement in the right nodule (Figs. 4f). The results for the various ultrasound modalities in the depiction of microvascular flow in thyroid nodules are summarized in Table 1. The consistency of scores for a subset of 52 nodules among the CDI/PDI, SMI, and CEUS images acquired by 2 independent operators was assessed. The k-coefficients of CDI/PDI, SMI, and CEUS were 0.949, 0.871, and 0.918, respectively. The diagnostic accuracies of the 3 methods are presented in Table 2. The accuracies of conventional ultrasound combined with CDI/ PDI, SMI, or CEUS for predicting malignancy were 67.31, 86.54, and 92.31%, respectively. SMI differed significantly from CDI/PDI (χ2 = 6.372, P = 0.012), but not from CEUS (χ2= 0.915, P = 0.339). Discussion Ultrasound is the primary imaging method for the evaluation of thyroid nodules [4]. Flow imaging of thyroid nodules can differentiate between benign and malignant

Lu et al. BMC Medical Imaging (2017) 17:65 Page 3 of 6 Fig. 1 Overall flow detection scored on a subjective scale of 0 to 10 for CDI, PDI, color SMI (csmi), monochrome SMI (msmi), and CEUS of average distribution for all nodules nodules. However, there are technical limitations in using CDI/PDI for detecting small blood vessels and low blood flow. Currently, microvessel density is the gold standard for determining tumor angiogenesis [8, 9]. The radiological evaluation of tumor angiogenesis includes morphological abnormalities of the microvessels, and differences in neonatal microvascular density and function [10, 11]. However, microvessel density can only be measured postoperatively, and therefore cannot be used to prevent unneeded invasive procedures, that is, for identifying benign lesions that should not be operated on. SMI is a relatively new imaging modality that is implemented on the Toshiba Aplio 500 ultrasound system. It enables better depiction of microvascularity and lowvelocity blood flow compared with conventional ultrasound methods. Low-level echoes that are near the noise level of the equipment, are detected by the SMI procedure for maximum information with minimum noise, but improper adjustment of the system gain may cause SMI imaging information distortion. In the present study, SMI did indeed reveal more small branches of microvasculature compared with CDI/PDI, and show the distribution Fig. 2 A papillary thyroid carcinoma located in the right lobe. a CDI and b PDI show peripheral and internal vascularity of the nodule, with c color SMI and d monochrome SMI depicting more detailed peripheral vascularity surrounding the nodule as well as internal disordered small branching microvessels. e Pulsed Doppler (guided by monochrome SMI) established that the small branching microvasculature was real and measurable. f CEUS features of the nodule. The nodule enhances later compared with normal thyroid parenchyma, with disordered heterogeneous hypoechoic enhancement and incomplete peripheral enhancement

Lu et al. BMC Medical Imaging (2017) 17:65 Page 4 of 6 Fig. 3 An isoechoic thyroid nodule located in the right lobe. a CDI and b PDI show some peripheral vascularization around the nodule. c Color SMI and d monochrome SMI show complete peripheral vascularization surrounding the nodule, with internal microvascularization and small branching details. e Pulsed Doppler (guided by monochrome SMI) established that the small branching microvasculature was real and measurable. f CEUS shows ring enhancement around the nodule and homogeneous internal enhancement. Histology: adenoma inside nodules and adjacent thyroid parenchyma in better detail. Judged by the detail in its images, SMI is highly accurate. According to several reports, CEUS is able to depict microperfusion in thyroid nodules. Zhang et al. [3] demonstrated that ring enhancement was closely associated with the benign character of lesions, whereas heterogeneous enhancement was helpful for detecting malignant lesions. Jiang reported that lower contrast enhancement levels are an important diagnostic indication of tiny papillary thyroid carcinoma [12]. This study compared SMI with CEUS and found that SMI provides better display of the network of small microvascular branches and their distribution in nodules, although Fig. 4 A papillary thyroid carcinoma ( ) and an adenoma ( ) coexist in the right lobe. a CDI and b PDI show peripheral vascularization and peripheral interrupted vascularization of the nodule and internal microvascularization. c Color SMI and d monochrome SMI show more vascularization, in particular curved and ring peripheral vascularization surrounding the nodule as well as internal microvascularization with small branching details. e Pulsed Doppler (guided by monochrome SMI) established that the small branching microvasculature was real and measurable. f CEUS shows disordered heterogeneous hypoechoic enhancement with incomplete peripheral enhancement ( ) and ring enhancement around the nodule and homogeneous hyperechoic internal enhancement ( ).

Lu et al. BMC Medical Imaging (2017) 17:65 Page 5 of 6 Table 1 CDI/PDI, SMI, and CEUS for depiction of microvascular flow distribution in thyroid nodules Disordered heterogeneous Homogeneous Ring None Sum CDI/PDI 40 3 3 6 52 SMI 38 5 7 2 52 CEUS 37 6 8 1 52 CEUS blood pool imaging can show thicker blood branches and vascular perfusion clearly. CEUS is believed by some researchers to have a high sensitivity to blood flow, resulting in coverage of real blood vessels [13]. However, another characteristic of CEUS is harmonic imaging, coupled with low mechanical index, low frequency, and a low frame rate (6-13 fps), which unfortunately affects the 2-dimensional display of the image. Another drawback of CEUS is variation in the contrast agent in-out time and patients swallowing, resulting in an unsatisfactory 3-dimensional display of microvasculature. In the present study, SMI and CEUS were similar in the high consistency of differentiation between benign and malignant nodules. The results of conventional ultrasound combined with CEUS tended to be better than those combined with SMI, but SMI is also the more economical method and avoids the hazards associated with the contrast agent used in CEUS. Furthermore, SMI has already shown potential in the characterization of brain tumors prior to surgery [14] and in the early diagnosis of breast cancer [15, 16]. Zhan et al. [14] considered the value of SMI when combined with conventional ultrasound without contrast administration and determined that SMI was helpful in the differential diagnosis of benign and malignant avascular breast lesions, especially those in BI-RADS category 4. To the best of our knowledge there is only one previous comparison in the literature of the diagnostic value of SMI and CEUS for the differentiation of tumors. This is a retrospective study by Xiao et al., [16] who compared the diagnostic utility of SMI and CEUS for breast lesions, using root hair-like and crab claw-like patterns as criteria for malignant lesions. Based on the microvascular architecture patterns, the sensitivity, specificity, and accuracy of monochromatic SMI for differentiation Table 2 Diagnostic accuracy of conventional ultrasound combined with CDI/PDI, SMI and CEUS in predicting benign and malignant thyroid nodules Benign or malignant Conform Not conform Sum CDI/PDI 35 17 52 SMI 45 7 52 CEUS 48 4 52 were 78, 91, and 85%, respectively, and the corresponding rates using CEUS were 90, 88, and 89%. Areas under the curve for monochromatic SMI and CEUS were not significantly different (P = 0.013) [15]. These breast cancer data are closely similar to the thyroid cancer data obtained in the present prospective study comparing SMI and CEUS for differentiating malignant from benign thyroid nodules. That is, we report an ~87% accuracy for SMI combined with conventional ultrasound, and a ~92% accuracy for CEUS with conventional ultrasound (P = 0.339). The main limitation in this study, is formed by the homogeneous background of the patients with none of the nodules being follicular carcinoma. Those typically require hemi-thyroidectomy or lobectomy for definitive diagnosis. Our results indicate that SMI has the potential to become the method of choice for detecting microvasculature in thyroid nodules. This conclusion is in accord with previous studies showing the use of SMI for better characterization of the vascularity of breast tumors [14, 15]. Blood flow detection and depiction of microvessel architecture are superior with this new noninvasive ultrasound imaging method. SMI combined with conventional ultrasound may become the tool of choice for differentiating benign from malignant thyroid nodules. Furthermore, because SMI does not require a contrast agent, it is more economical than CEUS and avoids the adverse reactions associated with the contrast agent. Conclusion SMI detects more small branches of microvasculature compared with CDI/PDI, and also shows the distribution inside nodules and adjacent thyroid parenchyma in better detail. SMI and CEUS are similar in the high consistency of differentiation between benign and malignant nodules, but SMI is also the more economical method and avoids the hazards associated with the contrast agent used in CEUS. Compared with conventional ultrasound, SMI therefore offers a superior alternative for the differentiation of benign and malignant thyroid nodules. Abbreviations CDI/PDI: Color/Power Doppler imaging; CEUS: Contrast-enhanced ultrasonography; SMI: Superb microvascular imaging Acknowledgements Not applicable Funding None Availability of data and materials The datasets used and/or analyzed during the current study are available from the corresponding author upon request.

Lu et al. BMC Medical Imaging (2017) 17:65 Page 6 of 6 Authors contributions RG and RJ designed the study. YZ and WZ collected and analysed the data. YX advised on histological staining and analysis. XW and ML contributed samples collection and intellectual input. RG and WZ drafted and wrote the manuscript. RJ revised the manuscript critically for intellectual content. All authors gave intellectual input to the study and approved the final version of the manuscript. RJ conceived the study, finalized the manuscript and acts as guarantor. All authors approved submission. Ethics approval and consent to participate The study was approved by the Institutional Review Board and Ethics Committee of Beijing Chao-Yang Hospital, Capital University of medical Sciences. Written informed consent was obtained from all individual participants included into the study. Consent for publication Not applicable 12. Jiang J, Liu N, Zhou Q. Diagnosis of thyroid microcarcinoma using contrastenhanced ultrasound. Chin J Ultrasonogr. 2012;21:595 7. 13. Chen HY, Chen Y, Zhu H. Comparative study of superb microvascular imaging and contrast-enhanced ultrasound in differentiating thyroid micronodules. Chin J Ultrasonogr. 2016;25:44 7. 14. Ishikawa M, Ota Y, Nagai M, Kusaka G, Tanaka Y, Naritaka H. Ultrasonography monitoring with superb microvascular imaging technique in brain tumor surgery. World Neurosurg. 2017;97:749.e11.e20. 15. Zhan J, Diao XH, Jin JM, Chen L, Chen Y. Superb microvascular imaging-a new vascular detecting ultrasonographic technique for avascular breast masses: a preliminary study. Eur J Radiol. 2016;85:915 21. 16. Xiao XY, Chen X, Guan XF, Wu H, Qin W, Luo BM. Superb microvascular imaging in diagnosis of breast lesions: a comparative study with contrastenhanced ultrasonographic microvascular imaging. Br J Radiol. 2016;89: 20160546. Competing interests The authors declare that they have no competing interests. Publisher s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Author details 1 Department of Ultrasonography, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100020, China. 2 Department of Endocrinology, Beijing No. 6 Hospital, Beijing 100007, China. 3 Department of Otorhinolaryngology Head and Neck Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100020, China. 4 Department of Pathology, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100020, China. Received: 12 June 2017 Accepted: 15 December 2017 References 1. Colonna M, Uhry Z, Guizard AV, Delafosse P, Schvartz C, Belot A, et al. Recent trends in incidence, geographical distribution, and survival of papillary thyroid cancer in France. Cancer Epidemiol. 2015;39:511 8. 2. Smith-Bindman R, Lebda P, Feldstein VA, Sellami D, Goldstein RB, Brasic N, et al. Risk of thyroid cancer based on thyroid ultrasound imaging characteristics: results of a population-based study. JAMA Intern Med. 2013;173:1788 96. 3. Zhang B, Jiang YX, Liu JB, Yang M, Dai Q, Zhu QL, et al. Utility of contrastenhanced ultrasound for evaluation of thyroid nodules. Thyroid. 2010;20:51 7. 4. Haugen BR, Alexander EK, Bible KC, Doherty GM, Mandel SJ, Nikiforov YE, et al. 2015 American Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association guidelines task force on thyroid nodules and differentiated thyroid cancer. Thyroid. 2016;26:1 133. 5. Niu LJ, Hao YZ, Zhou CW. Diagnostic value of ultrasonography in thyroid lesions. Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2006;41:415 8. 6. Wink O, Niessen WJ, Viergever MA. Multiscale vessel tracking. IEEE Trans Med Imaging. 2004;23:130 3. 7. Chen Y, Zhang Y, Yang J, Cao Q, Yang G, Chen J, et al. Curve-like structure extraction using minimal path propagation with backtracking. IEEE Trans Image Process. 2016;25:988 1003. 8. Weidner N. Current pathologic methods for measuring intratumoral microvessel density within breast carcinoma and other solid tumors. Breast Cancer Res Treat. 1995;36:169 80. 9. Elston CW, Ellis IO. Pathological prognostic factors in breast cancer. I. The value of histological grade in breast cancer: experience from a large study with long-term follow-up. Histopathology. 2002;41:154 61. 10. Shaked Y, Bertolini F, Man S, Rogers MS, Cervi D, Foutz T, et al. Genetic heterogeneity of the vasculogenic phenotype parallels angiogenesis; implications for cellular surrogate marker analysis of antiangiogenesis. Cancer Cell. 2005;7:101 11. 11. Testa AC, Ferrandina G, Fruscella E, Van Holsbeke C, Ferrazzi E, Leone FP, et al. The use of contrasted transvaginal sonography in the diagnosis of gynecologic diseases: a preliminary study. J Ultrasound Med. 2005;24:1267 78. Submit your next manuscript to BioMed Central and we will help you at every step: We accept pre-submission inquiries Our selector tool helps you to find the most relevant journal We provide round the clock customer support Convenient online submission Thorough peer review Inclusion in PubMed and all major indexing services Maximum visibility for your research Submit your manuscript at www.biomedcentral.com/submit