Algovita Spinal Cord Stimulation System

Similar documents
St. Jude Medical 8-Channel Adapter. Clinician's Manual

RestoreSensor Implant manual. Multi-program rechargeable neurostimulator. ! USA Rx only

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

Precision Montage MRI 16 Contact Implantable Pulse Generator

Surgical Leads. Directions for Use. CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician.

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

Lead and Extension Insertion Tool. Model Clinician's Manual

InterStim Therapy InterStim II Model 3058 Neurostimulator InterStim Model 3023 Neurostimulator

Implantable Pulse Generator. Prodigy IPG Prodigy MRI IPG. Clinician's Manual

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

PATIENT PROGRAMMER 37642

Remote control 2 guide

Initial placement 24FR Pull PEG kit REORDER NO:

Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards

Device Preparation (all steps to be performed per standard interventional technique)

The Biomet EBI Bone Healing System. Patient Manual

Percutaneous Leads. Directions for Use Content: REV A

Phonak PilotOne II. User Guide

TH Premium RIC LI 19. Guide for Hearing Care Professionals

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

Single Use Curlew TM Multiple Biopsy Forceps

Take control of your pain therapy. Getting started with Algovita SCS.

Initial placement 20FR Guidewire PEG kit REORDER NO:

Paddle Lead Kit. Models 3214, 3219, 3224, 3228, 3240, 3243, 3244, 3245, 3246, 3262, 3266, 3268, 3283, 3286, Clinician's Manual

Unitron remote control guide

User Manual.

Prodigy Neurostimulation System Programming and Reference. Models 3855, Clinician's Manual

Implantation Procedure

Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T

Mini Pulse Electronic Stimulator

PRO-DENSE BONE GRAFT SUBSTITUTE

Implantable Pulse Generator. Proclaim IPG. Clinician's Manual

Pain Relief Patch. Operation Manual Read Before Using MODEL # ET

Percutaneous Lead Kit. Models 3143, 3146, 3149, 3153, 3156, 3159, 3183, 3186, Clinician's Manual

PilotOne II. User Guide

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

TH CROS RIC 19 Transmitter. User Guide

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

SIX PACK ABS Item No INSTRUCTION MANUAL. Read entire manual before operating this product. Use only as directed.

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

User Manual Table of Contents. Instructions for Using the LaserTouchOne Charging the Unit... 5 Holding the Device... 5 Treatment Steps...

Safety manual for hearing instruments

Integra Flowable Wound Matrix

EVER Pharma D-mine Pen Pen injector for Apomorphine 10 mg/ml

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

Clinician's Manual. Paddle Lead Kit

Getting started with Wireless Fitting

Instructions for Use REMOTE CONTROL RC-N

Technique Guide Small Bone Fusion System

INSTRUCTIONS FOR USE AND CARE

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

INSTRUCTIONS FOR USE FOR:

DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

Electrodes (for TransAeris System)

SelectTech 3.1 Bench Assembly / Owner s Manual

Barostim neo. Hypertension CAUTION - INVESTIGATIONAL DEVICE. Limited by Federal (or United States) Law to Investigational Use.

FERTI CARE personal. User's Guide. Multicept A/S Frederiksberg Alle 32, 2.th DK-1820 Frederiksberg Denmark

User Manual CentrePoint Data Hub

Dr FuelCell Load Measurement Box

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

ProPocket TM. User Guide

FastFrame External Fixation System. Damage Control Surgical Technique

Medtronic MiniMed Insulin Infusion Pumps

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

EVOLVE TRIAD BONE SCREWS

FDA CLEARED for OVER THE COUNTER SALES (OTC) NO PRESCRIPTION REQUIRED. HiDow Wireless Tens/EMS Systems WIRELESS DEVICE INSTRUCTION MANUAL

Fibrlok II 2529 Universal Optical Fiber Splice

Compressor Nebulizer Instruction Manual Part No.: 5055

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

SUPER CPAP POWER PACK

Multipower. User Guide E S S E N T I A L S T R E N G T H

Attenti One-Piece Tracking Device 4

DISTAL RADIUS. Instructions for Use

with Blom-Singer Gel Cap Insertion System

VP2 electronic cigarette By VaprLife

TruGuard Custom Tongue and Jaw Positioner Instructions for Use

3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing Description 3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing is used

TRANSCUTANEOUS MECHANICAL NERVE STIMULATOR (TMNS) User s Guide

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

AWAY Model # RTLAGF-900 REV

INSTRUCTION MANUAL. Orascoptic 3225 Deming Way, Suite 190 Middleton, WI USA T:

ProVari Owner s Manual

Pure 312 Nx, Pure 13 Nx

Device Technical File

CLARIVEIN INFUSION CATHETER

SelectTech 4.1 Bench Assembly / Owner s Manual

USING YOUR INTELLIS IMPLANTABLE SPINAL CORD STIMULATION SYSTEM

Instructions for Use Reprocessed Arthroscopic Shavers

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

itaste CLK 1280说明书 尺寸 56*96mm 封面材质 157g 双铜板纸单面过哑胶 内页材质 128g 双铜纸双面印刷 装订方式 胶装 U S E R M A N U A L

RAPIDSORB RAPID ReSORBABLe CRANIAL CLAMP

ONLY. Physician Implant Manual

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

The following languages are included in this packet:

Transcription:

Algovita Spinal Cord Stimulation System Stimulator Models 2408 and 2412 For IPG replacement Implant Manual for Stimulator IPG implant.indb 1

Algovita is a trademark of QIG Group, LLC CoreGuard is a trademark of Greatbatch, Inc. Refer to the Information for Prescribers Manual for indications, contraindications, warnings, precautions, adverse events, and related information. FCC Information (US Only) The following is communications regulation information about the Algovita Implantable Pulse Generator (IPG). 2408 and 2412 IPG FCC ID: 2ABU824082412 These devices comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) These devices may not cause harmful interference, and (2) These devices must accept any interference received including interference that may cause undesired operation. Important: Changes and modifications to these products not authorized by Algostim, LLC could void the FCC certification and negate your authority to operate these products. IPG implant.indb 2

Algovita Spinal Cord Stimulation System Contents Explanation of Symbols Used on Packaging 5 Component Description 7 Package Contents 8 Component Sterilization 8 About this IPG Replacement Manual 8 Implant Procedure 8 Preparing for Surgery 8 Preoperative IPG Preparation 9 Explanting the IPG 13 Connecting the Leads or Extensions to the New IPG 13 Checking System Integrity 16 Implanting the New IPG 16 Completing the Implant Procedure 17 Patient Counseling Information 17 SCS System Implant: IPG Replacement 17 Registration Form and Temporary Patient ID Card 18 Returning Explanted Components 18 Algostim Customer Service 18 Specifications 19 Wireless Information 20 Algovita SCS System Component Compatibility 21 Stimulator Model 2408 and 2412 Implant Manual 3 IPG implant.indb 3

4 Stimulator Model 2408 and 2412 Implant Manual IPG implant.indb 4

Algovita Spinal Cord Stimulation System Explanation of Symbols Used on Packaging Symbol 20XX Explanation Conformité Européenne (European Conformity). This symbol means that the device fully complies with European Directive AIMD 90/385/EEC. Caution: Federal Law (USA) restricts this device to sale on or by the order of a physician. Consult instructions for use Caution Serial number Catalog number Model number Authorized representative in Europe Use by date Distributed by Manufacturer Temperature limit Keep dry Sterilized using ethylene oxide Do not resterilize Do not reuse Implant Manual for Stimulator 5 IPG implant.indb 5

Explanation of Symbols Used on Packaging Symbol Explanation Keep away from sunlight Do not use if package is damaged Phone Recycle Contents IPG: 3 connector ports with 8 channels each IPG: 2 connector ports with 12 channels each 6 Implant Manual for Stimulator IPG implant.indb 6

Algovita Spinal Cord Stimulation System Component Description The Algovita Stimulator Model 2408 or 2412 (Figure 1) is part of the Algovita Spinal Cord Stimulation (SCS) System, a rechargeable, 24-electrode, SCS system for the treatment of chronic pain. 1 2 3 1 2,LLC,LLC Figure 1. Algovita Stimulator Model 2408 and Model 2412 The Algovita Stimulator is the implantable pulse generator (IPG) for the Algovita SCS System. In addition to the IPG, the implanted components of the SCS system consist of percutaneous leads or paddle leads with optional extensions. During the intraoperative test, an external pulse generator (EPG) is used in place of the IPG. The clinician programs the IPG and the EPG using a Clinician Programmer. The patient adjusts the system using either of 2 patient programmers. Algovita IPGs are 24-channel rechargeable IPGs. Each channel allows the system 1 active electrode. The channels are distributed over 2 or 3 connector ports, depending on the IPG model. Algovita Stimulator Model 2408 (3x8 channel) Three connector ports accommodate 1 to 3 percutaneous leads, with each lead allowing up to 8 active electrodes. Algovita Stimulator Model 2412 (2x12 channel) Two connector ports accommodate 1 or 2 percutaneous or paddle leads, with each lead allowing up to 12 active electrodes. The IPG delivers stimulation using independent current distribution, a technology that allows variable amounts of current to be delivered to each active electrode. The IPG battery is a deep discharge recovery battery with CoreGuard technology. Even if the patient allows the battery to completely discharge, the battery can be recharged with the Algovita Programmer Charger. Implant Manual for Stimulator 7 IPG implant.indb 7

Package Contents Package Contents Stimulator Model 2408 (3x8) or Model 2412 (2x12) Torque wrench Port plugs (3 for Model 2408, 2 for Model 2412) Product literature Temporary patient ID card Implant registration form and business reply envelope Component Sterilization The implantable and surgical accessory components were sterilized with ethylene oxide prior to shipment. The SCS system sterile components are intended for single use only and must not be resterilized. Caution: Do not resterilize a system component or reimplant an explanted system component because of risk of infection or malfunction. About this IPG Replacement Manual This manual provides the instructions for the replacement of an Algovita Stimulator Model 2408 or 2412. For complete instructions on implanting an IPG as part of a system implant, refer to the system manual packaged in the lead kit. Implant Procedure Implanting clinicians should be thoroughly familiar with this manual and all other product labeling. Caution: Do not place the charging paddle on an unhealed wound. The charging paddle is not sterile. Contact with an unhealed wound may result in an infection. Preparing for Surgery Before opening the sterile pack, verify the following on the sterile pack label: IPG Model number and use-by date 8 Implant Manual for Stimulator IPG implant.indb 8

Algovita Spinal Cord Stimulation System Preoperative IPG Preparation Cautions: To allow the surgical wound to heal before another charge is needed, charge the IPG in its shelf carton before implanting. To assure maximum IPG battery life, make sure the IPG and its packaging are at room temperature before charging the IPG. Charging at temperatures above 35 C (95 F) can impair charging paddle operation. Do not implant the IPG if it has been dropped onto a hard surface. Use extreme care when handling system components prior to implantation. Excessive heat, excessive traction, excessive bending, excessive twisting, or the use of sharp instruments may damage a component, which may cause component failure. Before implanting an IPG, verify that the IPG is fully charged, verify IPG function, and determine the IPG implant site. A fully charged IPG allows the wound to heal before a recharge is needed. Verify that the IPG is functioning by using the Clinician Programmer to read the IPG battery charge level. (Refer to the Clinician Programming Manual for instructions on how to read the battery charge level.) To charge the IPG and verify that the IPG is functioning: 1. If the Programmer Charger needs charging, connect the power cord and AC power adapter to the Programmer Charger, and plug the AC power adapter into a wall outlet. Note: To determine if the Programmer Charger needs charging, see the Patient System Manual. 2. Connect the charging paddle to the Programmer Charger. 3. Turn the Programmer Charger on by sliding and holding the power on/off button on the side of the Programmer Charger. 4. Lift the flap on the top of the IPG shelf carton and place the charging paddle on the window over the IPG (Figure 2). Implant Manual for Stimulator 9 IPG implant.indb 9

1 2,LLC 1 12 12 24 Implant Procedure Figure 2. Preoperatively check the IPG 10 Implant Manual for Stimulator IPG implant.indb 10

Algovita Spinal Cord Stimulation System 5. When the Notification screen appears, select Cancel (Figure 3). Notification Not able to connect with IPG Cancel Retry Figure 3. Notification screen 6. When the Main screen appears, select (Figure 4). P Figure 4. Main screen Implant Manual for Stimulator 11 IPG implant.indb 11

Implant Procedure 7. While the IPG is charging, the Charge Status screen is displayed (Figure 5). Charge Status > Charge Status Charging in Progress OK OK Figure 5. Charging in progress. 8. When the Charge Status screen shows that charging is complete, select OK (Figure 6). Charge Status Charging complete OK Figure 6. IPG charging complete 12 Implant Manual for Stimulator IPG implant.indb 12

Algovita Spinal Cord Stimulation System Explanting the IPG 1. Turn off the IPG. 2. Place the patient in a position that will allow access to the IPG. 3. Use standard sterile technique to prepare and drape the patient. 4. Administer prophylactic antibiotics according to an infection control protocol. Caution: To help prevent infection, use prophylactic antibiotics. An infection may require the removal of the entire SCS system. 5. Using standard surgical technique, open the IPG pocket. 6. Remove the IPG from the pocket. 7. Use the Algovita torque wrench to unscrew the setscrews. 8. Remove the leads or extensions from the IPG header. 9. Return the explanted IPG components to Algovita as instructed in the Returning Explanted Components on page 18. Connecting the Leads or Extensions to the New IPG 1. Prepare the lead or extension for connection to the new IPG. a. Wipe the lead or extension contacts dry with sterile gauze. Note: Wipe gloves dry before drying or cleaning components. b. If the contacts came in contact with body fluids or saline, thoroughly clean the contacts with sterile deionized or sterile water, then dry them completely. Caution: Before connecting a lead or extension to the IPG, wipe off any body fluids and dry the connections. Fluids in the connections may result in stimulation at the connection site, intermittent stimulation, or loss of stimulation. c. Inspect the lead or extension for any evidence of damage or corrosion. Explant and replace any damaged or corroded component. 2. Fully insert each lead into the appropriate connector port. Caution: Do not use saline or other ionic fluids at connections. Ionic fluids in the connection may cause in a short circuit. a. Grasp the lead or extension in the middle of the contacts. Implant Manual for Stimulator 13 IPG implant.indb 13

Implant Procedure b. Slowly insert the lead or extension into the appropriate connector port (Figure 7), stopping when the lead or extension begins to meet resistance or your fingers touch the connector port. 1 2 1 2,LLC,LLC Figure 7. Insert the lead or extension into the connector port. c. Grasp the lead or extension near the setscrew ring (Figure 8). 1 2 1 2,LLC,LLC Figure 8. Grasp near setscrew ring. d. Using a steady force, continue inserting the lead or extension into the connector port. e. When the lead is fully inserted, you will see the end of the lead move to the back of the connector port and feel it stop against the back of the connector port. The setscrew ring will be aligned with the setscrew. f. Repeat the insertion steps for additional leads or extensions. 14 Implant Manual for Stimulator IPG implant.indb 14

Algovita Spinal Cord Stimulation System 3. Insert a port plug into any connector port not being used for this implant (Figure 9). 1 2,LLC Figure 9. Insert a port plug into any unused port. 4. Using the torque wrench provided in the IPG package, tighten each lead, extension, and port plug. Cautions: Use only the torque wrench that is part of the Algovita SCS System. Using another torque wrench may damage the lead, and may result in stimulation at the connection site, intermittent stimulation, or loss of stimulation. The torque wrench is single use only. Do not resterilize the torque wrench because of risk of infection or device malfunction. a. Fully insert the torque wrench into the grommet in the IPG header until it stops in the setscrew socket. Caution: Make sure the torque wrench is fully inserted into the grommet before tightening because the setscrew may be damaged, resulting in intermittent stimulation or loss of stimulation. b. Turn the torque wrench clockwise until it clicks once (Figure 10). If you continue to turn, the wrench will continue to click, but the additional turns do not tighten the setscrew further. Implant Manual for Stimulator 15 IPG implant.indb 15

Implant Procedure 1 2,LLC Figure 10. Tightening the setscrews. Checking System Integrity 1. To ensure the leads or extensions have been properly connected to the IPG and to rule out a short or open circuit, use the Clinician Programmer to program the basic stimulation parameters, check the battery charge level, and check the electrode impedances. 2. If the system integrity test results are not acceptable, check the connections made in Connecting the Leads or Extensions to the New IPG on page 13. Implanting the New IPG 1. Making sure of the following, place the IPG into the subcutaneous pocket (Figure 11): IPG is parallel to the skin and the Algovita logo is facing outward Lead or extension is loosely coiled behind the IPG with no sharp bends in the coils IPG is placed no deeper than 1.5 cm below the skin Caution: Ensure that the IPG is placed deep enough to avoid dehiscence or erosion. Also ensure that the IPG is placed no deeper than 1.5 cm (0.59 in) below the skin and is parallel to the skin. If the IPG is too deep or is not parallel to the skin, communication with the programmers and recharge connection may be inefficient or unsuccessful. 16 Implant Manual for Stimulator IPG implant.indb 16

1 2,LLC Algovita Spinal Cord Stimulation System Figure 11. Place the IPG in the pocket. 2. Secure the IPG in the pocket with a suture through each suture hole in the header. Completing the Implant Procedure 1. Close and dress all wounds. 2. Complete the implant registration form and return the documents to Algostim, LLC in the business reply envelope supplied in the packaging. 3. Fill out the temporary patient identification card. Patient Counseling Information Provide the patient with the appropriate information applicable to the SCS surgical procedure. SCS System Implant: IPG Replacement Provide your patient with postoperative care cautions that include the following: Not drive any vehicles or operate any other dangerous equipment (for example, power tools) with stimulation on Not engage in rigorous physical activity such as twisting, bending, or climbing Not stretch or reach the arms above the head Not lift objects weighing more than 5 pounds (2 kilograms) Not to place the charging paddle on an unhealed wound Implant Manual for Stimulator 17 IPG implant.indb 17

Registration Form and Temporary Patient ID Card Keep metal objects away from charging paddle Call your office: If patient notices redness around an incision, at any signs of bleeding, pus-like drainage, persistent drainage, redness, excessive swelling, or excessive pain At any signs or symptoms of extreme nausea or persistent headache At any signs of sudden severe pain, leg weakness, spasm, loss of bladder and/or bowel function If patient notices redness at the charging site If patient is not receiving adequate pain relief Registration Form and Temporary Patient ID Card At the time of implantation, complete the implant registration form in the product package and return it to Algostim, LLC. Registration initiates the system warranty. A temporary patient identification card is packaged with the IPG. A permanent identification card will be mailed to the patient when Algostim, LLC receives the implant registration form. Returning Explanted Components Return explanted leads, extensions, IPGs, and anchors to Algostim, LLC. The IPG should be explanted before cremation. The cremation process may cause the IPG battery to explode. Do not autoclave the components or expose them to ultrasonic cleaning. Dispose of unreturned components according to local environmental regulations. Algostim Customer Service If you have any questions about an Algovita SCS System, call Algostim Customer Services at XXX- XXX-XXXX. Algostim Customer Service is available 24 hours a day, 7 days a week. 18 Implant Manual for Stimulator IPG implant.indb 18

Algovita Spinal Cord Stimulation System Specifications Programmable parameter Number of programs 1 to 10 Table 1. Operating Values for Stimulator Model 2408 and 2412 Operating range and resolution a Number of pulses per subprogram 1 to 4 Electrode configuration 2 to 24 electrodes and IPG can as anode, cathode, or off Amplitude 0 to 15 ma per channel (IPG pulse maximum 30 ma) (Max 17 V) Pulse width 20 to 1500 μs (20 μs resolution) Frequency 2 to 2000 Hz (64 frequency options) Ramp on/off Off, On: 1, 2, 4, or 8 second duration a. The Algovita SCS System includes programmable coverage areas with each individual electrode contact limited to 15 ma. A programming interlock is enforced to limit the coverage area output current to 30 ma or less. Table 2. Component Materials for Stimulator Model 2408 and 2412 Components Material Material Contacts Human Tissue IPG Case Header Titanium Polysulfone Polyurethane Silicone Silicone rubber Setscrews Titanium Yes Torque wrench Handle Shaft Polyether ether ketone Stainless steel Port plugs Polyurethane Yes Yes Yes Yes Yes Yes Yes Yes Implant Manual for Stimulator 19 IPG implant.indb 19

Specifications Table 3. Specifications for Stimulator Model 2408 and 2412 Description Value Connector Type 3-Octapolar in-line 2.54 mm (0.100 in) spacing Model 2408 2-Dodecapolar in-line 2.54 mm (0.100 in) spacing Model 2412 Diameter 1.4 mm (0.05 in) Height 55.0 mm (2.2 in) Length 58.0 mm (2.3 in) Thickness Case 9.5 mm (0.4 in) Weight 40.0 g (1.4 oz) Volume 20.5 cm 3 2408, 19.5 cm 3 2412 (1.25 in 3 2408, 1.19 in 3 2412) Battery life 10 years Power source Lithium ion rechargeable battery fully recoverable battery Storage temperature 35 to 55 C (-31 to 131 F) Radiopaque Identification (ID) code ALG24 Lead retention strength Meets EN45502-1 requirements Wireless Information This transmitter is authorized by rule under the Medical Device Radiocommunication Service (in part 95 of the FCC Rules) and must not cause harmful interference to stations operating in the 400.150 406.000 MHz band in the Meteorological Aids (ie, transmitters and receivers used to communicate weather data), the Meteorological Satellite, or the Earth Exploration Satellite Services and must accept interference that may be caused by such stations, including interference that may cause undesired operation. This transmitter shall be used only in accordance with the FCC Rules governing the Medical Device Radiocommunication Service. Analog and digital voice communications are prohibited. Although this transmitter has been approved by the Federal Communications Commission, there is no guarantee that it will not receive interference or that any particular transmission from this transmitter will be free from interference. 20 Implant Manual for Stimulator IPG implant.indb 20

Algovita Spinal Cord Stimulation System Algovita SCS System Component Compatibility Only Algovita SCS System components should be used as part of an implanted Algovita SCS System. Table 4. Algovita SCS System Component Compatibility Stimulator Model 2408 (3x8) Extension Model 5208 (1x8) Stimulator Model 2412 (2x12) Extension Model 5212 (1x12) Trial Stimulator Model 4300 Clinician Programmer Model 4500 Programmer Charger Model 4200 Pocket Programmer Model 4100 For Placing 1 3 8-electrode Leads Percutaneous Lead Models 1081-xx 1, 1084-xx, 1086-xx Trial Lead Models 1081-xxT, 1084-xxT (Percutaneous) For Placing 1 2 12-electrode Leads Percutaneous Lead Models 1121-xx, 1124-xx, 1126-xx Paddle Lead Model 3000-xx (3-4-3-2) Paddle Lead Model 3101-xx (2x6) Trial Lead Models 1121-xxT, 1124-xxT (Percutaneous) 1. Denotes length Implant Manual for Stimulator 21 IPG implant.indb 21

Algovita SCS System Component Compatibility 22 Implant Manual for Stimulator IPG implant.indb 22

IPG implant.indb 23

Algostim, LLC 10675 Naples St. NE Blaine, MN 55449 763.786.7400 www.algostim.com Authorized Representative in Europe Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands (31) (0) 70 345-8570 Algostim, LLC 2014 All Rights Reserved Part Number 1006977 0300-000021-05 Revision 5 March 2014 IPG implant.indb 24