SedLine Sedation Monitor

Similar documents
Step by Step Description Use of Bonopty Coaxial Bone Biopsy System

Quick Notes. BioCapture : Acquiring EEG data

BIS Brain Monitoring for Critical Care

REFERENCE GUIDE USING THE BISPECTRAL INDEX (BIS ) MONITORING SYSTEM FOR CRITICAL CARE

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

English. Fealite Nasal Pillows System. User Manual

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

ISIS IOM. System-Family. The new ISIS Xpress supplements the ISIS IOM System-Family >> APPLICATION FIELDS: >> Powerful >> User-friendly >> Flexible

SIX PACK ABS Item No INSTRUCTION MANUAL. Read entire manual before operating this product. Use only as directed.

St. Jude Medical 8-Channel Adapter. Clinician's Manual

CHAPTER 6 INTERFERENCE CANCELLATION IN EEG SIGNAL

Electroencephalography

Muscle Stimulation. Page 1

CP lead resting electrocardiograph

NomoLine No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications

Single Use Curlew TM Multiple Biopsy Forceps

FT-302 Force Transducer

CAUTION...2 INSTRUCTION...5 IF-4000 INTERFERENTIAL STIMUATOR CONTROLS AND FUCTIONS...7 HOW TO USE YOUR IF-4000 STIMULATOR...14 ELECTRODES CARE...

Quick Notes. BioCapture : Acquiring Respiratory Effort data

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

ECG Check Wireless 1- Lead Cardiac Monitor. Rx Use

Supplemental Digital Content 1: Supplemental Results

COPYRIGHT Ramsey Medical, Inc.

Electroencephalograph EEG-9200J/K

NomoLine No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications

Contents of the Prodigy Pocket. Meter. PRODIGY Owner s Manual PRODIGY Owner s Manual

Lesson 1: Types of ECG s

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

BLINDED MODE USERS GUIDE SUPPLEMENT

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Pain Relief Patch. Operation Manual Read Before Using MODEL # ET

Human Brain Institute Russia-Switzerland-USA

with Blom-Singer Gel Cap Insertion System

TruGuard Custom Tongue and Jaw Positioner Instructions for Use

Mass Fusion Splicing of Optical Fiber Ribbon Cables

SENSATION and CS300 Smaller meets faster. IABP System

ECG Monitoring, Defibrillation and Synchronized Cardioversion with Hands-Free Electrodes

EEG History. Where and why is EEG used? 8/2/2010

DELSYS. Purpose. Hardware Concepts. Software Concepts. Technical Note 101: EMG Sensor Placement

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

EEG in the ICU: Part I

AXIOS Stent and Electrocautery Enhanced Delivery System. Quick Reference Guide

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

Where experience connects with innovation

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T

Matrix Energetics Research Brainwaves and Heart waves Research on Matrix Energetics in Action

8/20/ Identify the functions of common ECG machines. 3.3 Explain how each ECG machine control is used. 3.4 Recognize common electrodes.

MES 9000 MUSCULOSKELETAL EVALUATION SYSTEM

TIP CARD. Model Temporary External Pacemaker

Compressor Nebulizer Instruction Manual Part No.: 5055

Addendum: User Guide AutoPulse Resuscitation System Model 100 with Defibrillator Interface

The following describes general use of ELIOS device

FlexAbs EMS ABDOMINAL STIMULATOR. FlexBody. EMS Body Stimulator INSTRUCTION MANUAL

Device Preparation (all steps to be performed per standard interventional technique)

CDR Positioning System User Guide

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

Novel single trial movement classification based on temporal dynamics of EEG

Northeast Center for Special Care Grant Avenue Lake Katrine, NY

SelectTech 3.1 Bench Assembly / Owner s Manual

Localization a quick look

User Manual CentrePoint Data Hub

Quick Start Guide. Geriatric Tremor Simulator. Product Includes: Safety Instructions

Agile Product Lifecycle Management for Process

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Dosimeter Setting Device

Electrodes (for TransAeris System)

Nature Neuroscience: doi: /nn Supplementary Figure 1

The EEG Analysis of Auditory Emotional Stimuli Perception in TBI Patients with Different SCG Score

QUICK SETUP GUIDE SECULIFE DFBASE

Thought Technology Ltd.

EEG, ECG, EMG. Mitesh Shrestha

Brain Computer Interface. Mina Mikhail

TrueSight Personalized Planning & Targeting System. Operative technique

WAVELET ENERGY DISTRIBUTIONS OF P300 EVENT-RELATED POTENTIALS FOR WORKING MEMORY PERFORMANCE IN CHILDREN

1724 Lab: Frog Skeletal Muscle Physiology (Marieb Exercise 16A) Marieb/iWorx / Ziser, 2002

Quick Guide. for Treatment of Depression. with Brainsway dtms

Management of Central Venous Access Devices. Blood Glucose Monitoring

BIOPAC Systems, Inc BIOPAC Inspiring people and enabling discovery about life

For more information visit or contact hearx:

Contra-Indications, Warnings, Cautions & Precautions

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

Sleep Apnea Therapy Software User Manual

Processed by HBI: Russia/Switzerland/USA

EEG Changes (Research Abstracts)

Portable Equine Nebuliser System. User Manual

Testing the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device

User Guide and Operating Manual

Enhancing patient care in the ICU with NeuroMonitoring

Reader and Sensor Demo Kit. Quick Start Guide

iworx Sample Lab Experiment HP-7: Hypothesis-driven Biofeedback Lab/Research Study

Transcription:

SedLine Sedation Monitor Quick Reference Guide Not intended to replace the Operator s Manual. See the SedLine Sedation Monitor Operator s Manual for complete instructions, including warnings, indications for use, intended use, cautions, and notes.

Not intended to replace the Operator s Manual. SedLine is a patient-connected, 4-channel processed electroencephalograph (EEG) monitor designed specifically for intraoperative or intensive care use. It displays electrode status, EEG waveforms and Density Spectral Array (DSA). General knowledge of electroencephalograph (EEG) monitoring and an understanding of the features and functions of the SedLine Sedation Monitor are prerequisites for proper use. Display Window 1 Electrode Status Display (See Page 7) - Provides sensor electrode connectivity status to indicate whether electrode adjustment is warranted. Display Window Do not operate the SedLine Sedation Monitor without completely reading and understanding these instructions. Notice Purchase or possession of this device does not carry any express or implied license to use with replacement parts which would, alone or in combination with this device, fall within the scope of one of the relating patents. 2 3 EEG Display (See Page 8) - Reflects electrical activity of the frontal and prefrontal cortices of the brain. Electromyograph (EMG) - Measures detected muscle activity, such as grimacing or jaw clenching. This value ranges from 0 to 100%. Caution: Federal law restricts this device to sale by or on the order of a physician. For professional use. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events. 4 Patient State Index (PSi) (See Page 9) - A processed EEG parameter related to the effect of anesthetic agents. This value ranges from 0 to 100. For further information contact: Masimo Corporation 52 Discovery Irvine, CA 92618, USA Tel.: 949-297-7000 Fax.: 949-297-7001 Patents: /patents.htm EU authorized representative for Masimo Corporation: MDSS GmbH Schiffgraben 41 D-30175 Hannover, Germany 5 6 7 Suppression Ratio (SR) - Measures how much the electrical activity of the frontal and pre-frontal cortex of the brain is suppressed as a percentage of time. This value ranges from 0 to 100%. Artifact (ARTF) - Measures how much physiological (not brain-related) and environmental noise the system detects. This value ranges from 0 to 100%. Asymmetry Graph - Visualizes and quantifies the difference in brain activity between the left and the right sides using an asymmetry measurement. SedLine, Masimo, and are registered trademarks of Masimo Corporation. 2018 Masimo Corporation. All rights reserved. All other trademarks and registered trademarks are property of their respective owners. 8 Density Spectral Array (DSA) (See Page 10) - Uses color to represent the power levels of EEG between 0 and 30 Hz (Upper limit can be adjusted to 40 Hz). 2 Masimo 3 Masimo

Applying the RD SedLine EEG Sensor To apply the sensor and connect to a module: A B C D E F G 1. Prepare the forehead skin with alcohol and dry it before applying the sensor. 2. Peel the center of the sensor from the tray and discard (A). 3. Apply central electrodes onto the forehead. Center CT/CB electrodes on the forehead above the nose (B). 4. Press the central electrodes down firmly on to the forehead. Do not press directly on the electrode, otherwise the gel may leak out (C). 5. Apply R1/L1 to either side of CB. 6. Peel the outer electrodes R2/L2 from the individual trays and apply R2/L2 to the hairless area just above the temple (D). 7. Align the yellow indicator on the end of the patient cable to the yellow indicator on the sensor connecter. Push together until the sensor connector fits into the patient cable (E). 8. Push together until the sensor connector fits into the patient cable. 9. If any of the electrodes is displayed on screen in red, yellow, or blue, push or wiggle the white lining around the electrode until displayed in green. Do not press directly on the electrode as gel may leak out. 10. For additional details, see the SedLine Operator s Manual. Applying the Sensor Applying with the O3 sensor (when using O3 Regional Oximetry) Following the application of the RD SedLine EEG sensor, align the rounded section of each O3 sensor with the curved O3 sensor guidelines marked on the T-section of the RD SedLine EEG sensor (F) and position above L1/R1 and L2/R2 (G). 4 Masimo 5 Masimo

Electrode Status Display Electrode Status Examples The electrode status display provides the sensor s electrode conductance status. Display Description Action Impedance Value unavailable on CT Unreliable connection on L1 Green - Electrode impedance is within acceptable range. No electrode adjustment necessary. Yellow - Electrode impedance is marginal but acceptable. Red - Electrode impedance is out of acceptable range. Blue - Unreliable connection or disconnection of Sensor electrodes. Minor electrode adjustment may be required. 1. Gently push/wiggle electrodes until all are yellow and/or green. 2. Re-prepping of electrodes may be necessary. Confirm that all sensor electrodes, particularly electrodes CT and CB, are properly connected. Light Gray - Impedance values are 1. Replace the Patient Cable. unavailable because Sensor, Patient Cable, or Module is not adequately detected. 2. The Module may need to be replaced. Dark Gray with a Cyan X - Gel-bridging detected on the electrode. Dark Gray - Electrode monitoring disabled. All electrode icons will be dark gray. 1. Clean any gel that has leaked outside of the electrodes on the patient's forehead. 2. Confirm that all sensor electrodes are properly connected. 3. The Sensor may need to be replaced. Unacceptable impedance on CB 1. Confirm that Sensor is plugged into Patient Cable. 2. Confirm that Patient Cable is connected to Module. Gel-bridging between R1 and CB High but acceptable impedance on L2 Electrode Status Display 6 Masimo 7 Masimo

EEG Display Patient State Index (PSi) The EEG waveforms reflect electrical activity of the frontal and pre-frontal cortices of the brain. The display is configured to contain 4 data input sources, acquired from the 4 sensor electrodes: L1, R1, L2, and R2. The PSi is a processed EEG parameter that is related to the effect of anesthetic agents, and takes into consideration, among other factors: (1) changes in power in various EEG frequency bands; (2) changes in symmetry and synchronization between critical brain regions; and (3) the inhibition of regions of the frontal cortex. Horizontal axis represents time Expanding and Contracting Trend Pinch any trend display to expand or contract the timeframe displayed for all trending parameters. Vertical Axis Displays the amplitudes for different electrodes Trend PSi trend conveys PSi numeric values over a period of time. The horizontal axis represents time, and the timeframe displayed is configurable by the user. Numeric Value When there is insufficient EEG data to calculate a PSi, the PSi numeric value will be replaced by dashes (--) Default waveform speed is 30 mm/sec. Touch to configure speed. Default waveform amplitude is 5 uv/mm Touch to configure amplitude. Blue conveys that the PSi reading is below the userconfigurable lower limit. Green conveys that the PSi reading is within the userconfigurable limits. Yellow conveys that the PSi reading is above the userconfigurable upper limit. EEG and PSi 8 Masimo 9 Masimo

Density Spectral Array (DSA) Understanding the DSA Frequency Bands Representative EEG Waveforms Periods of artifact (ARTF) are conveyed by vertical white lines. Beta (13-30 Hz) Frequency Scale The DSA represents power between 0-30 Hz or 0-40 Hz. The L and R horizontal color graphs represent the activities of the EEG from the left and right frontal scalp regions, respectively. Alpha (8-12 Hz) Theta (4-8 Hz) Delta (0.5-4 Hz) 95% spectral edge frequency (SEF) is displayed on each of the left and right color graphs as a white trend line. Periods of suppression are conveyed by vertical black lines with a blue bar at the 0 Hz timeline for both the left and the right sides. (Periods of no data are conveyed by vertical black lines only.) Asymmetry Graph Visualizes and quantifies the difference in brain activity between the left and the right sides using an asymmetry measurement. DSA 10 Masimo 11 Masimo

Not intended to replace the Operator s Manual. See the SedLine Sedation Monitor Operator s Manual for complete instructions, including warnings, indications for use, intended use, cautions, and notes. 36000/PLM-10355B-0518