Right arm injection of contrast medium reduces venous artifacts in head and neck multislice spiral computed tomography angiography

Similar documents
CT angiography techniques. Boot camp

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Computed tomographic pulmonary angiography procedures: Contrast media dilution from the venous to the systemic circulation

YOU MUST BRING GLOVES FOR THIS ACTIVITY

VESSELS: GROSS ANATOMY

THE VESSELS OF BLOOD CIRCULATION

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate

Combined Anatomical and Functional Imaging with Revolution * CT

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Large veins of the thorax Brachiocephalic veins

Study of aortic ulcer by using MDCTA

10/14/2018 Dr. Shatarat

Upper Extremity Venous Duplex. Michigan Sonographers Society Fall Ultrasound Symposium October 15, 2016

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

EXPERIMENTAL AND THERAPEUTIC MEDICINE 9: , 2015

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

CT Chest. Verification of an opacity seen on the straight chest X ray

CT Versus MR for the Runoff

Renal vascular evaluation with 64 Multislice Computerized Tomography Daniela Stoisa, Fabrizzio E. Galiano, Andrés Quaranta, Roberto L.

After the Chest X-Ray:

Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

Cardiac Radiology In-Training Test Questions for Diagnostic Radiology Residents

3 Circulatory Pathways

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

For exam: VL DUPLEX EXTREMITY VEINS UNILAT LT

Cardiovascular system:

Original Article Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

Monophasic versus biphasic contrast application in CT of patients with head and neck tumour

Aortic Coarctation: Evaluation with Computed Tomography Angiography in Pediatric Patients

HUMAN HEART. Learn the following structures on the heart models.

Length Measurements of the Aorta After Endovascular Abdominal Aortic Aneurysm Repair

Detectability of subsegmental pulmonary vessels in 64 MDCT-pulmonary angiography.

X-Ray & CT Physics / Clinical CT

Magnetic Resonance Angiography

Pulmonary Embolism. Thoracic radiologist Helena Lauri

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

VENOUS DRAINAGE O US F UPPER UPPER LIM B BY dr.fahad Ullah

Breathing. Heart Rate

Case 9799 Stanford type A aortic dissection: US and CT findings

Computed Tomography of the Coronary Arteries

CRITICAL THINKING QUESTIONS AND ANSWERS AND CYCLE 2 LAB EXAM TEMPLATE. There are two main mechanisms that work in conjunction to return the blood

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

#5 Cardiovascular II Blood Vessels

Evaluation and treatment of intracranial aneurysms using Dual Energy CT Angiography (DECTA) and rotational Digital Subtraction Angiography (DSA).

#5 Cardiovascular II Blood Vessels

General Imaging. Imaging modalities. Incremental CT. Multislice CT Multislice CT [ MDCT ]

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

2 Synopsis Name and Address of Company: Bracco ALTANA Pharma GmbH Max-Stromeyer-Str. 116

Noncoronary Cardiac MDCT

Handzettel 1. CT Contrast Media. Agenda. Contrast Media Definition. Agenda. Why we need contrast media? Agenda

Lab 6: Blood. BIO104 Laboratory Handouts 147. Unit 12: Blood and Lymphatics. 1. Blood Characteristics Volume Functions Composition -

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

Metal Artifact Reduction by Dual Energy CT

MODULE 2: CARDIOVASCULAR SYSTEM ANTOMY An Introduction to the Anatomy of the Heart and Blood vessels

Cardiac Computed Tomography

Radiation Exposure in Pregnancy. John R. Mayo UNIVERSITY OF BRITISH COLUMBIA

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

Artery 1 Head and Thoracic Arteries. Arrange the parts in the order blood flows through them.

Human Anatomy Biology 351

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Upper Extremity Venous Duplex Evaluation

Sectional Anatomy Quiz - III

Lab Activity 25. Blood Vessels & Circulation. Portland Community College BI 232

A study on CT pulmonary angiography at low kv and low-concentration contrast medium using iterative reconstruction.

Mediastinum It is a thick movable partition between the two pleural sacs & lungs. It contains all the structures which lie

CT SCAN PROTOCOL. Shoulder

Dr. Weyrich G07: Superior and Posterior Mediastina. Reading: 1. Gray s Anatomy for Students, chapter 3

Cardiac Imaging Tests

Partial Anomalous Pulmonary Venous Connection in Adults: Evaluation with MDCT

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND

Exploration the Method of Low Dose Coronary Artery Imaging with Dual-Source CT

Day 5 Respiratory & Cardiovascular: Respiratory System

Three-dimensional CT angiography of the canine hepatic vasculature

Mediastinum and pericardium

Survey of patients CT radiation dose in Jiangsu Province

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

Guidelines, Policies and Statements D20 Statement on Peripheral Venous Ultrasound

(Non-EKG Gated) CTA Thoracic Aorta = CTA Chest

MR Advance Techniques. Vascular Imaging. Class II

Surface anatomy of Cardiovascular system

Chapter 14. The Cardiovascular System

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Lung Perfusion Analysis New Pathways in Lung Imaging. Case Study Brochure PLA 309 Hospital

Role of the Radiologist

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT

European Journal of Radiology

Pulmonary vascular anatomy & anatomical variants

Utility of CT angiography for pre-operative evaluation of robotic-assisted minimally invasive mitral valve surgery.

Computed tomography. Department of Radiology, University Medical School, Szeged

This lab activity is aligned with Visible Body s A&P app. Learn more at visiblebody.com/professors

2013 Coding Changes. Diagnostic Radiology. Nuclear Medicine

Interpreting CT Angiography: Three-Dimensional Reconstruction Techniques

Demographic and radiologic characteristics of patients with an accessory spleen: An octennial experience

Sheet lab 5 Anatomy: CT Scans

International Journal of Radiology

Transcription:

European Review for Medical and Pharmacological Sciences 2015; 19: 4698-4702 Right arm injection of contrast medium reduces venous artifacts in head and neck multislice spiral computed tomography angiography H. FANG 1, Y.-L. SONG 1, X.-S. LI 1, Y.-M. BI 1, P. WANG 1, H.-X. FAN 1, L.M. MENG 1, H.-X. HU 2 1 Department of Radiology, Chinese PLA Air Force General Hospital, Beijing, China 2 Department of Rehabilitation, Chinese PLA Air Force General Hospital, Beijing, China Abstract. OBJECTIVE: We tested whether injection of contrast medium via right or left arm would affect venous artifacts on head and neck multislice spiral computed tomography (CT) angiography. PATIENTS AND METHODS: 326 patients were enrolled. Each patient was injected with 10 ml of contrast medium at 5 ml/sec. Time of peak contrast value plus an additional 1 sec was defined as delay time. Another 40 ml of contrast medium were injected with the same injection speed. The scanning area ranged from the aortic arch to the top of the head. Left and right forearms were used for intravenous injections of contrast medium in, respectively, 151 and 175 patients. Comparative analyses of image quality included determining contrast medium residues remaining in the superior vena cava, brachiocephalic vein, or subclavian vein, and comparisons of quality of three-dimensional CT angiography. RESULTS: In 75% of head and neck angiographies, the delay time of the common carotid artery ranged from 16 to 22 sec. In 60% of the images, the quality was graded as excellent, with the left arm injection resulting in delay time of > 23 sec and the right arm delay time of > 18 sec. The CT imaging quality after contrast injections via left or right arms was statistically significant (p < 0.05). The image quality after right arm injection was better than after left arm injection. CONCLUSIONS: Intravenous injection of contrast medium via right arm reduces artifacts from contrast medium residues and improves the image quality of head and neck CT angiography. Key words: Computed tomography, X-ray, Angiography, Head and neck artery, Image quality, Contrast medium. Introduction Computed tomography (CT) has become an indispensable examination method to study blood vessels. CT shows blood vessels through sectioning, bone removal and three-dimensional recon- struction, and displays vascular lumens, vascular walls and perivascular tissue structures. These structures play an important role in the examination of the head and neck vascular lesions 1-3. Image artifacts are the main limitation affecting the quality of CT imaging. They convolute the reconstructed data of the image and affect the attenuation coefficient of the object. Notably, image artifacts arise because of machine- and operator-related factors. During the head and neck CT angiography, artifacts in the superior vena cava, subclavian vein and brachiocephalic vein affect the image quality. Currently, the causes of these artifacts are mostly attributed to breathing, heartbeat, and to concentration and dosage of contrast medium. The solutions proposed by many studies are a decrease of the volume of contrast medium, change of scanning direction, or a rapid injection of contrast medium 4,5. However, head and neck CT angiography is also determined by the site of contrast medium injection (i.e., via veins of left or right arm) 6,7. Up to now, very few studies with large sample sizes have evaluated the effects of administration routes of contrast medium on the distribution characteristics of the cervical arteries, and the results have not been clearly stated. Previously, in a small group of patients, we have demonstrated that artifact formation in clinical head and neck CT angiography significantly correlates with the route of contrast medium administration. In the present study with a large group of patients we further evaluated the effects of different routes of contrast medium administration on artifact formation during the head and neck angiography using the multislice spiral CT. Patients and Methods Patients A total of 342 patients who had undergone head and neck dual-source spiral CT angiography (Siemens Definition, Munich, Germany) at the 4698 Corresponding Author: Haixiang Hu, MD; e-mail: kzhuhaixiang@126.com

Right arm injection of contrast medium reduces venous artifacts in head and neck Department of Magnetic Resonance Imaging, Air Force General Hospital, were enrolled in our study from September 2008 to November 2012. The patient ages ranged from 50 to 65 years. Sixteen patients with thoracic neoplasms, cardiac insufficiency, or postoperative chest diseases were excluded from this study as they might have affected the carotid angiography. Intravenous injections of contrast medium in the left or right arms were respectively performed in 151 and 175 patients. Equipment The imaging was done using the SOMATOM Definition Dual-Source spiral CT (Siemens, Munich, Germany), Extravasation Detection Accessory double-syringe power injector, and contrast medium Ultravist 370 (370 mg/ml, Schering AG, Berlin-Wedding, Germany). Tests Patients fasted before the CT angiography exam. The injection was done as follows. The patient left or right forearm was used for a superficial venipuncture using 20-gauge disposable trocars. Then, the patient underwent CT angiography scanning while positioned in the posterioranterior and lateral position. After marking the position, scanning of the scout layer began from approximately 1 cm above the shoulder to approximately 5 cm from the head to define the monitoring layer in the clear layer of the common carotid artery and common jugular vein. We first used test bolus for the scan, then 10 ml of contrast medium were injected at 5 ml/sec, and a monitoring scan was performed to observe the monitoring. The scan was stopped immediately after enhancement was detected. The monitoring scan sequence was entered into the time-density curve (DnYEL). The analyzing window was used to obtain the time to peak-density curve as a function of the delay time of the artery and vein. The scanning direction was as follows: arterial phase was scanned from distal to proximal (head), whereas venous phase was scanned from proximal (head) to distal direction. After monitoring scan, the initial layer of CTA scan, parameters and delay times were defined. This was followed by injection of 40 ml of contrast medium at 5 ml/sec, after which another scan was started to complete the exam. Phase optimization was done as follows. The peak value of the common carotid artery timedensity curve and an additional 1 sec were defined as the delay time of head and neck angiography. The monitoring scan parameters were axial scan mode, tube current 20 mas, tube voltage 120 kv, 10 sec delay time from contrast medium injection to the beginning of monitoring scan, monitoring scan at every 0.33 sec (scan time), 1.16 sec cycle time, 1 x 10 mm acquisition mode, and 10 mm layer thickness (slice). The scanning parameters were: spiral pattern (Helical à Spiral), tube current of 200 ma, tube voltage of 120 kv, minimum 3 sec delay time from the axis scan mode of monitoring scan changing to helical scan mode, 0.33 sec tube ball rotation speed, 1.2 pitch, 300 mm scan field of view, 64 x 0.6 mm acquisition mode, 5 mm layer thickness slice, 5 mm layer spacing increment, and 5-6 sec scan time. Image post-processing The 5-mm scanned images were overlaid and reconstructed using 0.75-mm thick slices and 0.5 mm layer spacing. The reconstructed images were transferred to a workstation for post-processing. The arterial phase and unenhanced phase images with 0.75 mm layer thickness were placed into Neuro Dynamic System Analysis (DSA) window. The software processed the silhouettes automatically. The silhouette sequences went through the head and neck CT angiography reconstruction and were used for vascular analysis with application of volume rendering, maximum intensity projection, curve planar reconstruction, multiplanar reconstruction, and InSpace software methods. Table I. Demographic data of 326 study patients. Parameters Contrast medium Contrast medium p injection via left arm injection via right arm Age (full years) 54.7 ± 0.8 55.5 ± 0.9 > 0.1 Male/female gender 16/14 15/15 Body weight (kg) 60.5 ± 9.1 59.2 ± 8.2 Body height (cm) 167.9 ± 9.2 166.3 ± 9.0 Body mass index, BMI 21.9 ± 2.0 22.5 ± 3.0 4699

H. Fang, Y.-L. Song, X.-S. Li, Y.-M. Bi, P. Wang, H.-X. Fan, L.M. Meng, H.-X. Hu Figure 1. Distribution of delay time in the common carotid artery in 326 patients during head and neck CT angiography. Image evaluation After the image silhouettes were prepared, superior vena cava, brachiocephalic vein, and subclavian vein were observed for contrast medium residues that could lead to artifacts on the angiograph. The image quality was classified as follows: excellent (no artifacts appear in the superior vena cava, brachiocephalic vein and only slight residues are seen in the subclavian vein), good (no artifacts are detected in the superior vena cava, but artifacts are present in the brachiocephalic and subclavian veins), and poor (artifacts present in the superior vena cava, brachiocephalic vein and subclavian vein). Statistical Analysis The findings were evaluated by two experts, and statistical analysis was performed according to the medical information. The SPSS17.0 statistical software (SPSS Inc., Chicago, IL, USA) was used to analyze the data. Differences between groups were assessed by the Wilcoxon rank-sum test. The p < 0.05 was considered as indicating statistically significant difference. Results This study included 326 patients: 179 male and 147 female patients, ages ranging from 50 to 65 years ([mean ± SEM] age of 55.16 ± 0.93 years). There was no significant difference between the patients who received contrast medium via the left or right arm (Table I). The delay time of the common carotid arteries in these patients showed that this parameter in most (75%) patients) ranged from 16 to 22 sec (Figure 1). The distribution of the image quality in patients who received contrast medium via left or right arm is shown in Figures 2 and 3. Sixty percent of the images were graded as having excellent quality, with left arm delay time of >23 sec (Figure 2) and right arm delay time >18 sec (Figure 3). These differences were statistically significant (Table II). Figure 2. Imaging quality in patients after contrast medium injection via left arm. Sixty percent of images achieve excellent quality grade with the left arm delay time of > 23 sec. 4700

Right arm injection of contrast medium reduces venous artifacts in head and neck Figure 3. Imaging quality in patients after contrast medium injection via right arm. Sixty percent of the images achieve excellent quality grade with the right arm delay time of > 18 sec. Discussion We performed a comparative analysis of image quality of neck multislice spiral CT angiography in 326 patients. Our findings indicated that intravenous injection of contrast medium via right arm led to a shorter delay time to reach excellent grade images. In some patients, delay times were quite stable, with a large proportion ranging from 16-22 sec. This could significantly reduce the occurrence of venous artifacts in neck angiography. The main factor to determine this difference may be related to anatomy. During the forearm intravenous injection, the route of contrast medium consists of superficial veins of the upper limb. The injection site was either cephalic, median, or basilic veins of the forearm. Contrast medium moves along these vessels and reached the axillary vein to enter the subclavian vein to continue through the brachiocephalic vein and superior vena cava to finally enter into the heart. Then, it further goes through the pulmonary circulation into the left ventricle. The pumping of the left ventricle allows the contrast medium to enter the aortic arch. The aortic arch generally has the following three main branches: (1) brachiocephalic trunk, which bifurcates into right subclavian artery and right common carotid artery, (2) the left common carotid artery, and (3) the left subclavian artery 8,9. We combined the knowledge from the circulation route of the contrast medium with the information from literature and compared the anatomical structures of the left and right sides to determine whether there were significant differences between the two sides 10. The right brachiocephalic vein is approximately 2.5 cm long and straight, and originates after the convergence of the right subclavian vein with the right internal jugular vein. The right brachiocephalic vein is almost vertically anterior to the brachiocephalic trunk, drains into the superior vena cava, and does not intersect with other vessels. The flow direction of the left brachiocephalic vein is diagonally towards the right, with approximately 6 cm of length, where it crosses the left brachiocephalic vein and the front of the aortic arch and intersects with other vessels. The diameter of the left brachiocephalic vein is significantly smaller than that of the right brachiocephalic vein. Therefore, when the contrast medium is administered into the right arm, larger diameter, and short and straight flow direction prevent residue formation and thereby reduce the occurrence of the artifacts. In addition, reflux occurs less often. The main branches of the subclavian vein are the external jugular vein and the dorsal scapular vein. Some people have only a few venous valves in the subclavian and external jugular veins. In addition, the function of venous valves declines with age 8. Moreover, the left brachiocephalic vein is longer. Table II. CT imaging quality. Poor quality Good quality Excellent quality (number) (number) (number) Contrast medium injection via left arm 58 57 36 Contrast medium injection via right arm 24 42 109 p = 0.002 4701

H. Fang, Y.-L. Song, X.-S. Li, Y.-M. Bi, P. Wang, H.-X. Fan, L.M. Meng, H.-X. Hu It crosses diagonally between the sternum and the innominate artery and forms an angle with the superior vena cava. At this angle, the left brachiocephalic vein is easily compressed, resulting in a narrowed vein. The high-pressure contrast medium injection easily refluxes, which hardly occurs when the injection is done through the right brachiocephalic vein 11,12. Studies have reported that the left brachiocephalic vein is located in the anterior space of the anterior mediastinal vessels. During thoracic breathing or postural changes, this space narrows down. With the large dose and high-speed intravenous injection, the contrast medium may be retained in the distal ends of the left subclavian and brachiocephalic veins. The intravenous contrast medium may also reflux and produce artifacts that affect the image quality 13. Another study 14 on the reflux conditions of left arm intravenous injection demonstrated that intravenous injection in the upper left arm had significantly more frequent reflux episodes than in the upper right arm, and this is consisted with our conclusions. In addition, time is a key factor to the success of CT imaging. In this study, the test bolus scanning technology was used to monitor and compare the delay time of the patients. The results suggest that intravenous injection via the right upper arm may fulfill the image requirement earlier, which improves the success rate of CT scanning. In addition, excluding the shoulders from the scanning may show a clear level in the monitoring layer of the CT angiography scan in the common carotid artery and common jugular vein. Due to low ma of the monitoring scan, thick shoulder tissue may diminish x-ray penetration. This may also cause artifacts and inaccurate peak-density detection, resulting in the failure of CT scan. Conclusions In the absence of other special circumstances, the use of the right upper arm for intravenous injection of contrast medium significantly reduces artifacts in the superior vena cava, brachiocephalic vein and subclavian vein during head and neck CT angiography. Conflict of Interest The Authors declare no conflicts of interest. References 1. KUMAMARU KK, HOPPEL BE, MATHER RT, RYBICKI FJ. CT angiography: current technology and clinical use. Radiol Clin North Am 2010; 48: 213-235. 2. SABA L, ANZIDEI M, SANFILIPPO R, MONTISCI R, LUCATELLI P, CATALANO C, PASSARIELLO R, MALLARINI G. Imaging of the carotid artery. Atherosclerosis 2012; 220: 294-309. 3. BUERKE B, WITTKAMP G, SEIFARTH H, HEINDEL W, KLOS- KA SP. Dual-energy CTA with bone removal for transcranial arteries: intraindividual comparison with standard CTA without bone removal and TOF-MRA. Acad Radiol 2009; 16: 1348-1355. 4. KURODA Y, HOSOYA T, ODA A, OOKI N, TOYOGUCHI Y, MURAKAMI M, KANOTO M, SUGAWARA C, HONMA T, SUGAI Y, NEMOTO K. Inverse-direction scanning improves the image quality of whole carotid CT angiography with 64-MDCT. Eur J Radiol 2011; 80: 749-754. 5. SAADE C, BOURNE R, WILKINSON M, EVANOFF M, BREN- NAN P. A reduced contrast volume acquisition regimen based on cardiovascular dynamics improves visualisation of head and neck vasculature with carotid MDCT angiography. Eur J Radiol 2013; 82: e64-69. 6. DEMIRPOLAT G, YUKSEL M, KAVUKCU G, TUNCEL D. Carotid CT angiography: comparison of image quality for left versus right arm injections. Diagn Interv Radiol 2011; 17: 195-198. 7. CHEN M, GUO H, HE J. [Difference quality of thoracic enhanced CT images by right- or left-side ulnar vein injection]. J Clin Radiol 2010; 29: 1107-1109. in Chinese. 8. STANDRING S. Gray's anatomy, Elsevier, Singapore, 2007. 9. GAO S, LI Y, ZHANG P. [Practical altlas of brain vessels], Science Press, 2008. in Chinese. 10. LU F, LUO T, XIE P. [Anatomical CT study of brachiocephalic vein]. Chin J Med Imaging Technol 2007; 23: 1663-1665. in Chinese. 11. LAWLER LP, CORL FM, FISHMAN EK. Multi-detector row and volume-rendered CT of the normal and accessory flow pathways of the thoracic systemic and pulmonary veins. Radiographics 2002; 22 Spec No: S45-60. 12. DE MONYE C, CADEMARTIRI F, DE WEERT TT, SIEPMAN DA, DIPPEL DW, VAN DER LUGT A. Sixteen-detector row CT angiography of carotid arteries: comparison of different volumes of contrast material with and without a bolus chaser. Radiology 2005; 237: 555-562. 13. KISHIMOTO M, YAMADA K, TSUNEDA R, SHIMIZU J, IWASA- KI T, MIYAKE Y. Effect of contrast media formulation on computed tomography angiographic contrast enhancement. Vet Radiol Ultrasound 2008; 49: 233-237. 14. TSENG YC, HSU HL, LEE TH. [Venous reflux on carotid computed tomography angiography: relationship with left-arm injection]. Venous Reflux in CT Angiography 2007; 31: 360-364. in Chinese. 4702