General Single Ion Calibration. Pete 14-May-09

Similar documents
MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Cloud Condensation Nuclei Counter (CCN) Module

Allergy Basics. This handout describes the process for adding and removing allergies from a patient s chart.

The following describes general use of ELIOS device

Raw BP and Eight Hemodynamic Measurements Displayed in Real Time

Sleep Apnea Therapy Software Clinician Manual

Sleep Apnea Therapy Software User Manual

QSTAR Operation. May 3, Bob Seward

Navigating the Business (ISR) Workplace

Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch

Warfarin Help Documentation

Step-by-Step RECD Guide

Patient Safety Queries DMARDs, Warfarin and Triple Whammy. Version th July User Guide for GP Practices SPIRE Local (v1.2.

Welcome! With a little effort you can have a big effect

Beltone Solus Pro 1.9 Fitting Guide

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Add_A_Class_with_Class_Number_Revised Thursday, March 18, 2010

Overview. Page 1 of 9. Impedance Cardiography

Introducing.. PIKA (Ochotona princeps)

RELEASED. Clearing your active insulin

Appendix B. Nodulus Observer XT Instructional Guide. 1. Setting up your project p. 2. a. Observation p. 2. b. Subjects, behaviors and coding p.

Welcome to CareLink Pro

Time-of-Flight Aerosol Mass Spectrometer Instrument & Winter Data

Fully Automated IFA Processor LIS User Manual

Thermo Finnigan. 6-2 LCQ Advantage Getting Started-

GYMTOP USB PROFESSIONAL 20143

Fizzy Extraction of Volatile and Semivolatile Compounds into the Gas Phase

Dosimeter Setting Device

GLOOKO FOR ios MIDS USER GUIDE

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

Comparing the Functional Performance of BIOPAC Respiratory Belt-Transducers With and Without Repair Tape

Audiological Bulletin no. 46

INSTRUCTOR WALKTHROUGH

Demo Mode. Once you have taken the time to navigate your RPM 2 app in "Demo mode" you should be ready to pair, connect, and try your inserts.

BEMC/BSMD O.Tsai, 04/13/2006 Latest Update 01/30/2014

STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES

Voxar 3D CardiaMetrix. Reference Guide

LEFT VENTRICLE SEGMENTATION AND MEASUREMENT Using Analyze

User Manual. RaySafe i2 dose viewer

CROS System Initial Fit Protocol

BlueBayCT - Warfarin User Guide

Bruker D8 Discover User Manual (Version: July 2017)

version User s Guide nnnnnnnnnnnnnnnnnnnnnn AUTOMATIC POULTRY SCALES BAT2 Lite

Hearing Control App User Guide

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

ENZO 3D First fitting with ReSound Smart Fit 1.1

Thrive Hearing Control App User Guide for Apple. Congratulations on your journey to better hearing

Dosimeter Setting Device System NRZ

Software Training Manual

Add_A_Class_with_Class_Search_Revised Thursday, March 18, 2010

The North Carolina Health Data Explorer

Iso-inertial dynamometer

Matrix sentence test (Italian)

BSL PRO Lesson H03: Nerve Conduction Velocity: Along the Ulnar Nerve of a Human Subject

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015

SMART HEARING. resoundpro.com. ReSound Aventa 3.9 fitting guide

AURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04

Quick Notes for Users of. Beef Ration and Nutrition. Decision Software & Sheep Companion Modules

Exercise 6: Muscle Physiology II Twitch & Summation

cigarettedesigner 4.0

MODULE: SQUAT JUMP BRIEF DESCRIPTION:

Science in Sport. 204a ECG demonstration (Graph) Read. The Electrocardiogram. ECG Any 12 bit EASYSENSE. Sensors: Loggers: Logging time: 10 seconds

VMA Demo Unit. Introduction. This document provides information on how to set up and operate the VMA Demo Unit. Figure 1: VMA Demo Unit

Tips & Tricks Kaltura Captioning

Registration Instructions Thank you for joining the Million Mile Movement!

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Managing and Taking Notes

1724 Lab: Frog Skeletal Muscle Physiology (Marieb Exercise 16A) Marieb/iWorx / Ziser, 2002

Click on the Case Entry tab and the Procedure Menu will display. To add new procedures, click on Add.

Monitor Instructions for Models: CHB-R6 CHB-UV6

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Managing and Taking Notes

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

Two-Way Independent ANOVA

Luminosity Monitor and Test Run Results. Presented by: Luis Mercado UMASS Amherst 7/23/08

Kappa Apex3 instruction manual. Procedure. Version 1.0 CuKα / MoKα Duo Edition

INRODUCTION TO TREEAGE PRO

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

ReSound ENZO 3D fitting guide. A guide for professionals

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

Simple Strategies for GC/MS Success. Rachael Simon Agilent Technologies Product Manager, Gas Chromatography Supplies

Hanwell Instruments Ltd. Instruction Manual

For Electric Personal Dosimete Dose-i

SOFTWARE INSTRUCTION MANUAL

TruLink Hearing Control App User Guide

Living with Newton's Laws

Beltone Boost Max Fitting guide. A guide for professionals

Titrations in Cytobank

Sample Preparation is Key

Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications

Skeletal muscles are composed of hundreds to thousands of individual cells,

Walkthrough

Program instructions

CST for Windows. Version 1.0 Revised: 7/29/13. Software to administer and score the Connected Speech Test (CST)

The Hill s Healthy Weight Protocol User Guide. Effective

Evolve 3 & 5 Service Manual

< > INVISALIGN OUTCOME SIMULATOR QUICK REFERENCE GUIDE. Home Contents Overview Important Notes. STEP 1 Scan Patient s Teeth Submit Scan

Cochlear Baha 4 Fitting Software 4.0 Desk Reference

Introduction. What s new in Genie 2?

Transcription:

General Single Ion Calibration Pete 14-May-09

Purpose of SI calibration Measure the instrument response of a single ion. Necessary for understanding of error in instrument (counting statistics) Calculation of AB and IE The value is important, but cancels out in the calculation of mass.

How to Do SI calibration m/z calibration baseline / threshold calibration check for saturation look at SI values thresholding (advanced diagnostics) m/z ratio - in particular 40/28 if on a HR-ToF-AMS do it for BOTH modes

m/z calibration the m/z calibration window is also where you can tune the instrument

m/z calibration 1.) 2.) 3.) 4.) 1.Line up the masses in the 3 boxes using the arrows 2.Check that the points fall in or close to the blue dotted lines 3.Check that the points fall on a line 4.If all is okay, press save all and exit 5.If the points are not on a line, then one of the masses is probably off.

Bitwise window The bitwise window is where one can check the baseline, thresholding, Saturation, and single ion

Baseline / Threshold 2.) 1.) 4.) 3.) 1.Set the MCP value to Low which = 1000 V (wait until value read value reaches 1000) 2.Press Start and wait for at least 30 passes to complete then press stop. 3.Inspect the baseline, if all appears okay, then press Set Baseline 4.Reset the MCP to the Menu Val wait for the Read value to reach the set value, and then wait for another minute or so.

Baseline Check Output raw electronic baseline Set electronic baseline in ADC Blue line should be in center of green trace Set Threshold value in ADC This graph shows the electronic noise around the baseline. In general one does not want vertical bars exceeding your threshold value red line at bottom. One should not adjust the baseline to prevent this, as that can reduce the linearity of the ion measurement and compromise data quality. The next tests guide ones decision on the threshold value

1.) Check for Saturation and SI setup 1. Check the Advanced Diagnostics box 2. I generally like to set the Pk. Discrim. above the Threshold value by 1-2 bits (Play with this and see how it affects the SI value 3. Click D in the SI masses. I often remove inorganic ions such as 46, 64, and some lower masses such as 14 4. Make sure the Chopper is open and the valve is too, since we first check for Saturation of the detector 5. Press Start - then the graphs will appear, and you will start to see the SI value calculated. 2.) 3.) 5.) 4.)

Recalculate SI with blocked if in V mode 1. See how frequently the m/z 28 signal saturated the ADC card. If the probability is << 1% this should be okay. 2. If in V-Mode changing the chopper value to blocked is recommended for the SI determination. If in W-mode, one does not need to do this, and can skip the the next slide. 3. Press Start - then the graphs will appear, and you will start to see the SI value calculated. 1.) 3.) 2.)

Reading the Values 1. Check the SI value from m/z 40 (if Pk Prob < 10%) 2. Check the SI value from the default list of masses 3. Enter one of the values into the SI box. IMPORTANT: be consistent with the whichever one you choose. With the newer versions of the software there is automatic monitoring which uses the default list. 3.) 1.) 2.)

1.) 2.) Peaks:Threshold 1. This window can be found in the tab Peaks: Threshold 2. These plots show how the area of the Single ion changes with Threshold setting. Typically one wants the measured single ion to be >90% of the raw data. If it is low, then the MCP voltage may need to be increased.

m/z ratios 1.) 1.Change to the MS Ratios Tab 2.Put a filter on the Inlet, make sure valve is open 3.Set Avg. Time to 5 Sec for C-ToF or V-mode or 30 Seconds for W-Mode 4.Press Start 4.) 3.)

m/z ratios output 3.) 1. This window scan through the thresholds from raw to 15 bits, and calculates the signal at m/z 32, 28, and 40. 2. The Ratio of m/z 40/28 is a key diagnostic for the instrument performance and quatitation. 3. For Ambient air this is the ratio to Argon to N2 and in this window the absolute value should be around 0.022 for the threshold used when measuring (when duty cycle corrected in the DAQ window and in Sqrl the number is 0.018) 2.)

Baseline, SI, and Threshold Baseline set in instrument based on electronic noise with low V on MCP Saturation of m/z 28 checked to see if MCP too high (if too high reduce emission current or MCP) Single Ion value determined from m/z 40 or default ion list, and updated in text box Threshold parameters checked Check 40/28 ratio to make sure threshold value is appropriate for measurement