Flow in re-stenosed artery after angioplasty

Similar documents
Particle Hemodynamics Analysis after Coronary Angioplasty

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION

Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY

Morphological changes after percutaneous transluminal coronary angioplasty of unstable plaques

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis

Blood flow in vessels with artificial or pathological geometrical changes

Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics

Comparison of Stent Designs using Computational Fluid Dynamics

Simulations of the blood flow in the arterio-venous fistula for haemodialysis

Analysis of the effects of plaque deposits on the blood flow through human artery

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images

Noninvasive Fractional Flow Reserve from Coronary CT Angiography

Arteriovenous Graft Modeling and Hemodynamic Interpretation

Extraction and FSI modeling of Left coronary artery structure from patient s CTA images

Assessment of the Effects of Increasing Levels of Physiological Realism in the Computational Fluid Dynamics Analyses of Implanted Coronary Stents

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries

Physiological Flow Simulation in Residual Human Stenoses After Coronary Angioplasty

FFR CT : Beyond FFR. Bon-Kwon Koo, MD, PhD. Seoul National University Hospital, Seoul, Korea. Seoul National University Hospital Cardiovascular Center

Rheology update in Cardiovascular disease

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture

Physiological flow analysis in significant human coronary artery stenoses

March 12th, 2018, Orlando FL. The American College of Cardiology 67 th Annual Scientific Meeting

Identification of Atherosclerotic Lesion-Prone Sites through Patient-Specific Simulation of Low-Density Lipoprotein Accumulation

Between Coronary Angiography and Fractional Flow Reserve

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft

Wall Shear Stress Distribution in Patient Specific Coronary Artery Bifurcation

FFR and intravascular imaging, which of which?

BLOOD FLOW THROUGH A COMPOSITE STENOSIS IN CATHETERIZED ARTERIES INTRODUCTION

A Review of Study of the Effects of Plaque Deposits on the Blood Flow through Human Artery

A computational fluid dynamics simulation study of coronary blood flow affected by graft placement

Edinburgh Imaging Academy online distance learning courses

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

A Two-layered Model for the Analysis of Arterial Rheology

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics

Estimation and Comparison of T Graft Versus Conventional Graft for Coronary Arteries

Intravascular Ultrasound for Complex Cases

FFR Fundamentals and Measurements

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study

The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries

CVS Hemodynamics. Change in blood pressure:

Medical device design using Computational Fluid Dynamics (CFD)

Intracoronary Serum Smooth Muscle Myosin Heavy Chain Levels Following PTCA may Predict Restenosis

Blood Flow Patterns in the Proximal Human Coronary Arteries: Relationship to Atherosclerotic Plaque Occurrence

Left main coronary artery (LMCA): The proximal segment

Numerical analysis of blood flow in human abdominal aorta

Simulation of Physiological Non-Newtonian Blood Flow through 3-D Geometry of Carotid Artery with Stenosis

Correlations of coronary plaque wall thickness with wall pressure and wall pressure gradient: A representative case study

La dissection aortique de type B : Dépistage et Suivi

Vascular reconstruction: CFD predictions of bypass graft haemodynamics

Intravascular Ultrasound

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial

Study of Newtonian and Non-Newtonian Effect of Blood Flow in Portal Vein in Normal and Hypertension Conditions using CFD Technique

Developing Pulsatile Flow in a Deployed Coronary Stent

FOR many decades, cardiovascular disease has been one of

Computational Fluid Dynamics Analysis of Blalock-Taussig Shunt

Asymmetric flows of non-newtonian fluids in symmetric stenosed artery

Percutaneous Intervention of Unprotected Left Main Disease

Roles of Flow Mechanics in Vascular Cell Biology in Health and Disease

CVS Hemodynamics. Faisal I. Mohammed, MD,PhD.

UNDERSTANDING ATHEROSCLEROSIS

Flow features in and around a (stented) coarctation

Making the difference with Live Image Guidance

Form 4: Coronary Evaluation

NUMERICAL SIMULATION OF EFFECTS OF REYNOLDS NUMBER ON NON-NEWTONIAN BLOOD FLOW WITH SPIRAL COMPONENT THROUGH A REGULAR STENOSED ARTERY

Form 4: Coronary Evaluation

analysis demonstrated a large and highly significant reported results suggesting the optimal balloon: artery

Investigation of metallic surface area of coronary stents

Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel

Percutaneous Transluminal Coronary Angioplasty of the Very Proximal Coronary Artery Stenosis

Side Branch Occlusion

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

Treatment of lesions at bifurcations: General perspective

ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions

Post-conditioning. P a g e 1. To my Thesis Committee,

Catheter Interventions for Kawasaki Disease: Current Concepts and Future Directions

Clinical Investigation and Reports

Effectiveness of IVUS in Complex Cases

Basics of Angiographic Interpretation Analysis of Angiography

Radiation Safety Abbott Vascular. All rights reserved.

Original. Stresses and Strains Distributions in Three-Dimension Three-Layer Abdominal Aortic Wall Based on in vivo Ultrasound Imaging

Investigation of the Hemodynamics of Coronary Arteries - Effect of Stenting. Naresh Kumar Coimbatore Selvarasu

Deposited on: 21 January 2009

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Debate Should we use FFR? I will say NO.

Development of Computational Models for Evaluation of Mechanical and Hemodynamic Behavior of an Intravascular Stent

Low fractional diastolic pressure in the ascending aorta increased the risk of coronary heart disease

Relationship between plaque development and local hemodynamics in coronary arteries

FSI Analysis of Diseased Coronary using Patient Specific Data

Transcription:

Data Management and Security 209 Flow in re-stenosed artery after angioplasty S. I. Bernad 1, A. Totorean 2, E. S. Bernad 3 & R. Susan-Resiga 2 1 Romanian Academy, Timisoara Branch, Romania 2 Politehnica University of Timisoara, Romania 3 University of Medicine and Pharmacy Timisoara, Romania Abstract Coronary angiogram (CA) is the gold standard diagnostic tool for coronary artery stenosis. Restenosis after balloon angioplasty is the major limitation of the technique. The goal of the paper is to evaluate the way in which the wall shear stress (WSS) distribution is affected by the blood flow evolution during the cardiac cycle in re-stenosed arterial segment. Coronary angiography was performed 2 months after percutaneous transluminal coronary angioplasty (PTCA). Angiographic evidence of restenosis was defined as 40% diameter stenosis at the site of the previous dilatation. After angioplasty of stenotic lesions, the luminal geometry is drastically changed. The maximum value of the WSS is at the critical height of the stenosis. A large separation zone is observed downstream to the stenosis, characterized by low WSS region. The range of WSS varies from 2 to 24 Pa. In conclusion, the arterial remodeling is highly relevant to the process of re-stenosis and is an important adaptive response to changes in flow and local shear stress. Keywords: blood flow, right coronary artery, angioplasty, hemodynamics, pressure drop. 1 Introduction It is widely believed that atherosclerosis development and progression are affected by many risk factors, such as static pressure, wall shear stress, blood viscosity, flow velocity, etc. Vascular geometry is another factor influencing strongly the flow patterns and generating a pre-existing atherogenic hemodynamic environment [1, 2]. When atherosclerosis develops, advanced lesions form first in some regions with adaptive intimal thickening. doi:10.2495/data130191

210 Data Management and Security Adaptive intimal thickening may be thought of as the consequence of a range of physiological stimuli, constituting an attempt by the tissue to maintain normal conditions of flow, wall tension, or both. Intima, as a living, reactive tissue, adapts in thickness to changes in pulse rate, blood pressure, arterial geometry, flow rate, and resistance to flow in distal vascular segments and in supplied organs [3, 4]. The flow phenomena in the stenotic arteries include asymmetric flow, instabilities and laminar to turbulent transition [5]. The unsteady flow in a stenotic artery also is characterized by high pressure and wall shear stress (WSS) in the throat and distal to the stenosis [6]. Coronary angiogram is the gold standard diagnostic tool for coronary artery stenosis. Restenosis after balloon angioplasty (BA) is the major limitation of the technique. Excessive neointimal proliferation and extracellular matrix synthesis by modified smooth muscle cells in response to injury have been suggested as the main mechanisms of restenosis [7]. The goal here is twofold. First the velocity and pressure distributions at the locations of constricted region are evaluated. Second the way in which the WSS distribution is affected by the blood flow evolution during the cardiac cycle in stenosed region are investigated. 2 Materials and method 2.1 Quantitative angiography In total, three coronary angiograms are obtained for the patient: before and after percutaneous transluminal coronary angioplasty (PTCA) and at angiographic follow-up. The procedure was considered successful when the residual luminal narrowing in the dilated segment immediately after angioplasty was <50% and when no major complication (electrocardiography ECG or enzymatic evidence of myocardial infarction) occurred. A suboptimal result was defined as the presence of a visually estimated residual stenosis >40% after dilatation with or without an associated nonocclusive dissection but with normal blood flow. The anatomical and geometric measurement is performed by contrast angiography. 2.1.1 Patient follow-up Coronary angiography techniques are performed 2 months after PTCA in order to provide hemodynamic and anatomic data of the right coronary artery (RCA). Angiographic evidence of restenosis was defined as 40% diameter stenosis at the site of the previous dilatation. The degree of stenosis was evaluated by quantitative coronary angiography with automatic edge detection. Calibration of the diameter of the vessels in absolute values (in millimeters) was achieved with the diagnostic or guiding catheter used as a reference. Measurements were repeated three times, and the mean values were recorded.

Data Management and Security 211 (a) (b) (c) (d) Figure 1: Invasive coronary angiography and angioplasty on the right coronary artery (RCA). (a) RCA mid segment stenosis (angiographic image); (b) balloon inflation during the angioplasty; (c) RCA after angioplasty; (d) RCA restenosis at 2 months after intervention (angiographic image). Table 1: Baseline clinical characteristics of the patient before CA. Patient data Characteristics Sex M Age, (y) 52 Smoker Previous myocardial infarction Previous CABG Previous PTCA Diabetes mellitus History of hypertension History of hypercholesterolemia History of peripheral vascular disease

212 Data Management and Security Clinical characteristics of patient before coronary angiography are presented in Table 1, and angiographic data obtained during the coronary intervention are presented in Table 2. Table 2: Baseline angiographic data of patient before coronary angioplasty. Angiographic data Characteristics Number of diseased vessels SVD 2-VD - 3-VD - Lesion location LAD - LCx - RCA Type of lesion Multiple irregularities Side branch in lesion - Lesion calcification - PTCA procedure minal size of largest balloon [mm] - Balloon to artery ratio Total number of inflations 1 Total duration of inflation [s] 84 Maximum inflation pressure [atm] 6 Post-PTCA result Dissection at the dilated site Thrombus visible (before or after PTCA) Reference diameter [mm] Before 3.01 After 3.02 Minimal luminal diameter [mm] Before 1.2 After 2.7 Diameter stenosis [%] Before 60 After 10 2.2 Vascular model Figure 2 shows the reconstructed lumen geometry of the RCA. Anatomical measurements are performed by contrast angiography. The lumen inlet diameter, (d e ) in equal to 3 mm and the diameter of the lumen in the throat of the stenosis, (d t ) is equal to 1.8 mm. SVD indicates single-vessel disease; 2-VD, two-vessel disease; 3-VD, threevessel disease; LAD left anterior descending; LCx left circumflex artery; RCA right coronary artery; and PTCA percutaneous transluminal coronary angioplasty, CABG coronary artery bypass graft.

Data Management and Security 213 The percentage diameter reduction for a circular stenosis is 1-d t /d e and the diameter of the occluded artery (d r ) is equal to (d e ). The RCA is modelled to be 20 mm in length with variable diameters, depending of the stenosis severity. Data corresponding to the reconstructed stenosis is presented in Figure 2. Figure 2: Dimensions of the stenosis at follow-up investigation. Patient specific RCA geometry reconstruction (corresponding to the stenosed region). S1 S4, correspond to the different investigated sections. Geometric measurements are performed by contrast angiography. 2.3 Numerical model Three different meshes were investigated. The number of cells varied between 200,000 and 700,000. A high mesh resolution near the walls was needed for accurate values of pressure drop and WSS (Figure 3(a)). Thus the mesh was refined in the near-wall region. To model the flow close to the wall, standard wall-function approach was used. (a) (b) Figure 3: (a) Computational domain discretization; (b) Physiologically realistic boundary conditions based on flow waveform acquired with an intravascular ultrasound Doppler probe in the RCA. diastolic dominant flow waveform.

214 Data Management and Security The governing equations are solved iteratively until convergence of all flow variables is achieved. The convergence criterion was set to 10-6 for the residuals of the continuity equation and of X, Y and Z momentum equations. Computational assumptions and boundary conditions are the following: the blood is assumed incompressible having dynamic viscosity (μ) of 0.00408 Pa.s and a density (ρ) of 1050 kg/m 3. Calculated Womersley numbers Wo = R(2πfρ/μ) 0.5 (where R = 3 mm is the artery radius and f = 72 bpm is the heart frequency) were found to be low in coronary arteries (Wo = 4.). The blood flow velocity profile in the human artery tends to be laminar and parabolic because of the friction (wall shear stress) between the viscous blood and the inner surface of blood vessel [8]. The governing equations for incompressible blood flow are the Navier-Stokes equations and are solved iteratively until obtain the required numerical precision. The numerical simulations are performed using the commercial CFD package FLUENT 6.3 [9]. The velocity profile at the inlet section is identical to the real coronary ostium velocity profile presented in Figure 3(b). In this model the vessel wall is a rigid wall. Researchers from different groups [10, 11] conclude that arterial wall motion had little effect on the hemodynamic parameters distributions within the RCA. 3 Results During clinical angioplasty, balloon sizes, inflation pressures, and time could also influence the extent and shape of vessel wall injury. However, assuming the balloon is appropriately sized and inflation pressure is adequately applied, balloon inflation exerts a relatively uniform tensile stress along the entire circumference of the lesion. The physical structure and property of the lesion determine where the stretching or splitting will occur [12]. The numerical simulation result show the hemodynamic parameters of the blood flow in the re-stenosed coronary artery under physiological conditions (velocity, pressure and wall shear stress distribution). 3.1 Velocity distribution Variation of axial velocity profiles during the cardiac cycle at progressive locations along the lesion are in Figure 4 at mean flow rates t = 0.4s in Figure 3(b). Along the constriction region where spatial flow acceleration occurs, the velocity profiles at the midpoint are steeper in the wall region and somewhat more uniform in the higher velocity core flow, although the shapes of the profiles vary during the cardiac cycle, and with mean flow rate. In the throat region where mean flow velocities are highest along the lesion, the velocity profiles at the midpoint indicate that viscous effects are more confined to the near wall region with a more uniform core flow (like boundary layer type flow) during the cardiac cycle (Figure 5).

Data Management and Security 215 Figure 4: Velocity vector distribution in different cross sections in distal part of the re-stenosed RCA artery. 3.2 Pressure distribution First, the flow enter in the constriction and the increase in velocity (Figure 5) results in a steep drop in the pressure coefficient which reaches the minimum value at the constricted region (Figure 6). Beyond this point, the flow enters the expansion and the pressure coefficient exhibits a steep increase. Separation of flow can also contribute to pressure loss and is a major factor at lower percent stenoses. A strong shear layer at the interface of the separation region and the central jet creates additional viscous losses. The throat of the stenosis is a site of high shear stress rates at the wall, which also contribute to viscous losses. 3.3 Wall shear stress distribution A primary signal for arterial remodeling is shear stress, which is the frictional force at the endothelial surface produced by flowing blood [13, 14]. Because the vessel narrows at the stenosis, the velocity at the center of the vessel increases due to the conservation of mass law. The velocity gradient at the wall and the resulting WSS is maximum in the narrowest portion of the stenosis. Figure 7(b) shows the calculated WSS distribution variation along the stenosis. The artery radius starts at 3 mm, gradually narrows to 1.8 mm at the stenosis, and then expands after the stenosis to about 3 mm. Along to the arterial wall, the WSS varies significantly from point to point. The WSS is low outside the stenosis, suddenly increases with the narrowing diameter, and reaches a maximum at the smallest diameter inside the stenosis (Figure 7(b)). Distal to the sudden expansion of the stenosis, the vortex backflow produces low WSS values. The maximum value of wall shear stress is at the critical height of the stenosis (Figure 7(b)). A large separation zone is observed also downstream to the stenosis (characterized by low WSS region).

216 Data Management and Security Figure 5: Iso-velocity distribution for time step t = 0.64 s (diastolic decceleration phase) in the investigated stenosis (time step correspond to the time steps indicated in Figure 3(b)). Top: isovelocity contour for velocity of 0.02 m/s; bottom: iso-velocity contour for velocity of 0.9 m/s. The range of WSS in this figure varies from 2 to 24 Pa. Large intense regions of low WSS appear downstream at the stenosis. For this region the WSS is approximately 2 Pa. The maximum WSS in the stenosis is about 24 Pa.

Data Management and Security 2 Figure 6: Axial pressure distribution for different time steps in re-stenosed RCA. 4 Conclusion Arterial remodeling is highly relevant to the process of atherosclerosis and is an important adaptive response to changes in flow and local shear stress. Restenosis is the result of the interaction between different biologic determinants. We conclude that one major determinant that influence the

218 Data Management and Security (a) (b) Figure 7. Disturbed flow indicators at the time t=0.64 s. (a) particles pattline shows large recirculation region distal to the stenotic segment; (b) temporal WSS magnitude contours around to the throat (value are in [Pa]). restenosis is the regional flow characteristics (determined by the geometry of the dilated lumen of the lesion and blood flow velocity patterns across that lumen). In the clinical setting, a less than satisfactory residual lumen after coronary angioplasty or a postdilated residual stenosis greater than 30% is associated with increased restenosis [15]. This is probably because a larger postdilation residual stenosis tends to be associated with a greater flow separation area (were the low shear stress promote intimal growth).

Data Management and Security 219 With regard to fluid dynamics in the case of poststenotic regions, the areas of low wall shear stress are also associated with flow separation. This is important because it has been suggested that the fluctuation of wall shear stress or existence of the disturbed flow leads to increased endothelial cell turnover and intimal thickening [16, ]. Glossary BA balloon angioplasty, CA coronary angiogram, CABG coronary artery bypass graft, ECG electrocardiography, LAD left anterior descending, LCx left circumflex artery, RCA right coronary artery, PTCA percutaneous transluminal coronary angioplasty, SVD single-vessel disease, 2-VD two-vessel disease, 3-VD three-vessel disease, WSS wall shear stress. References [1] S.R. Dodds, The haemodynamics of asymmetric stenoses, European Journal of Vascular and Endovascular Surgery, 24, 332 337, 2002. [2] D. Zeng, E. Boutsianis, M. Ammann, K. Boomsma, S. Wildermuth, D. Poulikakos, A study of the compliance of a right coronary artery and its impact on wall shear stress, Journal of Biomechanical Engineering, 130, 041014 11, 2008. [3] P. H. Stone, A. U. Coskun, S. Kinlay, et al, Regions of low endothelial shear stress are the sites where coronary plaque progresses and vascular remodelling occurs in humans: an in vivo serial study, Eur Heart J, 28, 705 710, 2007. [4] H.C. Stary, D.H. Blankenhorn, A.B. Chandler, S. Glagov, W. Insull, Jr. M. Richardson, A definition of the intima of human arteries and of its atherosclerosis- prone regions. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association, Circulation, 85, 391 405, 1992. [5] J.R Buchanan., C. Kleinstreuer, Simulation of particle-hemodynamics in a partially occluded artery segment with implications to the initiation of microemboli and secondary stenoses, Journal of Biomechanical Engineering, 120, 446 454, 1998. [6] J.-J. Ciu, D.L. Wang, S. Chien, R. Skalak, S. Usami, Effects of disturbed flow on endothelial cells, Journal of Biomechanical Engineering, 120, 2 8, 1988.

220 Data Management and Security [7] G.E. Austin, N.B. Ratliff, J. Hollman, S. Tabei, D.F. Philips, Intimal proliferation of smooth muscle cells as an explanation for recurrent coronary artery stenosis after percutaneous transluminal coronary angioplasty, J Am Coll Cardiol, 6, 369 375, 1985. [8] A.M. Malek, S.L. Alper, S. Izumo, Hemodynamic shear stress and its role in atherosclerosis, Jama, 282, 2035 42, 1999. [9] FLUENT 6.3 User s Guide, Ansys Fluent Incorporated, 2006. [10] Y. Qiu, J.M. Tarbell, Numerical simulation of pulsatile flow in a compliant curved tube model of a coronary artery. J. Biomech. Eng., 122, 77 85, 2000. [11] A. Santamarina, E. Weydahl, J.M. Siegel Jr., J.E. Moore Jr., Computational analysis of flow in a curved tube model of the coronary arteries: Effects of time-varying curvature, Ann. Biomed. Eng., 26, 944 954, 1998. [12] R.T. Lyon, C.K. Zarins, C.-T. Lu, C.-F. Yang, S. Glagov, Vessel, plaque and lumen morphology after transluminal balloon angioplasty: Quantitative study in distended human arteries, Arteriosclerosis, Thrombosis and Vascular Biology, 7, 306 314, 1987. [13] M. Heil, W. Schaper, Influence of mechanical, cellular, and molecular factors on collateral artery growth (arteriogenesis). Circ Res., 95, 449 458, 2004. [14] N. Resnick, H. Yahav, A. Shay-Salit, M. Shushy, S. Schubert, L.C. Zilberman, E. Wofovitz, Fluid shear stress and the vascular endothelium: for better and for worse. Prog Biophys Mol Biol., 811, 7 199, 2003 [15] P.P. Leimgruber, G.S. Roubin, J. Hollman, G.A. Cotsonis, B. Meier, J.S. Jr Douglas, S.B. III King, A.R. Gruentzig, Restenosis after successful coronary angioplasty in patients with single vessel disease, Circulation, 73, 710 7, 1986. [16] C.K. Zarins, R.A. Bomberger, S. Glagov, Local effects of stenoses: Increased flow velocity inhibits atherogenesis, Circulation, 64 (suppl II): II-221-II-227, 1981. [] B.L. Langille, F. O Donnell, Reductions in arterial diameter produced by chronic decrease in blood flow are endotheliumdependent, Science, 231, 405 407, 1986.