Vitamin A-E Serum HPLC Analysis Kit

Similar documents
PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

FinTest IgG4 Screen 20 ELISA KIT

Mouse C-Peptide ELISA Kit

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

Bovine Insulin ELISA

Porcine/Canine Insulin ELISA

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

FinTest TM IgG4 Screen 88 ELISA Kit

Iodine HPLC Assay. Catalog Number: IOD34-H Tests For Research Use Only. Not for use in diagnostic procedures.

Insulin (Porcine/Canine) ELISA

Rat Proinsulin ELISA

Procine sphingomyelin ELISA Kit

Rat Hemoglobin A1c (HbA1c) Kit Instructions

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

Mouse C-peptide ELISA

Serum Amyloid A ELISA

Mouse C-peptide ELISA

Morinaga Mouse C-peptide ELISA Kit

Mouse C3 (Complement Factor 3) ELISA Kit

Mouse Ultrasensitive Insulin ELISA

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Apolipoprotein A-1 ELISA

Vedolizumab Drug Level ELISA

STELLUX C-peptide Chemiluminescence ELISA

Chymotrypsin ELISA Kit

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

MALDI Sepsityper Kit

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

Human Thyroid Stimulating Hormone CLIA kit

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

BÜHLMANN fcal turbo. Calprotectin turbidimetric assay for professional use. Reagent Kit B-KCAL-RSET. Revision date:

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma

25(OH) Vitamin D ELISA (BD-220BA), 192 Tests

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

HbA1c (Human) ELISA Kit

Organic Acid Urine LC-MS/MS Analysis Kit

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

VGKC-Autoantibody Assay RIA

Insulin Rodent (Mouse/Rat) Chemiluminescence ELISA

Influenza A IgG ELISA

TNF-alpha ELISA. For Research Use Only. Not For Use In Diagnostic Procedures.

Ultra-sensitive Human TSH ELISA Kit. MyBioSource.com

Fish follicle-stimulating hormone, FSH ELISA Kit

Triiodothyronine (T3) ELISA

Mouse Leptin ELISA Kit Instructions

ab Lipase Activity Assay Kit (Colorimetric)

Cotinine (Mouse/Rat) ELISA Kit

Instructions for Use. IA2 Antibody ELISA. Enzyme Immuno Assay for the Quantitative Determination of Antibodies against IA-2 in Serum.

Mouse serum Insulin 200 tests

DRG International, Inc., USA Fax: (908)

Mouse/Rat THYROXINE (T4) ELISA Catalog No (96 Tests)

retardation in infants. A wide variety of analytical methods for the analysis of

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

GLP-2 ELISA. For the quantitative determination of GLP-2 in human serum and plasma samples.

Mouse GLP-2 EIA FOR LABORATORY USE ONLY

SERION ELISA classic CMV Avidity Reagent B109 AVID

Human Thyroglobulin EIA

Rat cholesterol ELISA Kit

Nitrate/Nitrite Assay Kit Manual Catalog #

Insulin Chemiluminescence ELISA

Myeloperoxidase (MPO) ELISA Stool, Urine KIT

Human Free Thyroxine (ft4) CLIA Kit

Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

FOR LABORATORY USE ONLY

Product # Kit Components

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

VITAMIN B1 IN WHOLE BLOOD BY FLUORIMETRY - FAST Code Z85010

Rat Glicentin EIA FOR RESEARCH USE ONLY. <Distributed by> DF Kasumigaseki Place, 3-6-7, Kasumigaseki, Chiyoda-ku Tokyo Japan

ab Lipase Activity Assay Kit (Colorimetric)

ab TSH Receptor Autoantibody ELISA Kit

Rubella virus IgG ELISA Kit

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

I. Introduction. II. Characteristics

Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Dienes Derivatization MaxSpec Kit

ABIOpure TM Viral (version 2.0)

Clinical Chemistry (CHE 221)

Kit Components Product # EP42720 (24 preps) MDx 2X PCR Master Mix 350 µl Cryptococcus neoformans Primer Mix 70 µl Cryptococcus neoformans Positive

Ⅰ.Introduction. Ⅱ.Characteristics

Human HIV (1+2) antigen&antibody ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit

TSH ELISA Kit Medical Device Licence No.: 16419

PLATELIA CANDIDA Ab PLUS Negative and Positive Controls. Quality Control Human Sera

ab Hemoglobin Human ELISA Kit

Rat C-Peptide EIA. Cat. No. YII-YK010-EX FOR LABORATORY USE ONLY

Norgen s HIV proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad icycler

Transcription:

Vitamin A-E Serum HPLC Analysis Kit ZV-4013-0200-10 200 2-8 C ZIVAK TEKNOLOJI SANAYI VE TICARET LIMITED SIRKETI Gursel Mh. Eski Besiktas Cd. No:44/1-2 KAGITHANE-ISTANBUL-TURKEY www.zivak.com info@zivak.com +90 (212) 210 62 15 FAX: +90 (212) 210 62 14

INDEX Table of Contents Page 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST PRINCIPLE... 3 4. WARNING AND PRECAUTIONS... 3 5. STORAGE AND STABILITY... 4 6. MATERIALS SUPPLIED:... 4 7. MATERIALS REQUIRED BUT NOT SUPPLIED... 4 8. PROCEDURE NOTES... 5 9. LIMITATIONS OF THE PROCEDURE... 5 10. PRE-TEST SET UP INSTRUCTIONS... 5 11. TEST PROCEDURE... 6 12. QUALITY CONTROL... 6 13. CALCULATION OF RESULTS... 6 14. INTERPRETATION OF RESULTS... 7 15. EXPECTED VALUES... 7 16. HPLC-ECD PARAMETERS... 8 17. ANALYTICAL PERFORMANCE... 8 18. SAMPLE CHROMATOGRAMS... 8 Page 2 / 8

1. INTENDED USE: Quantitative HPLC analysis kit for Vitamin A and Vitamin E in human serum &plasma samples. 2. SUMMARY AND EXPLANATION: The level of vitamin A in the plasma or serum is a reflection of the quantities of vitamin A and carotene ingested and absorbed by the intestine. Vitamin A plays an essential role in the function of the retina (adaptation to dim light), is necessary for growth and differentiation of epithelial tissue, and is required for growth of bone, reproduction, and embryonic development. Together with certain carotenoids, vitamin A enhances immune function, reducing the consequences of some infectious diseases. Vitamin A in excess can be toxic. Vitamin E contributes to the normal maintenance of biomembranes, the vascular system, and the nervous systems; and provides antioxidant protection for vitamin A. Deficiency of vitamin E in children leads to reversible motor and sensory neuropathies; this problem also has been suspected in adults. Deficiencies of vitamins A and E may arise from poor nutrition or from intestinal malabsorption. People, especially children, at risk include those with bowel disease, pancreatic disease, chronic cholestasis, celiac disease, cystic fibrosis, and intestinal lymphangiectasia. Vitamin A-E HPLC Analysis Kit was developed for rapid, sensitive and reliable quantitative detection of the Vitamin A-E concentrations in human serum samples and it gives results in 8 minutes with minimal sample preparation. Main methods and procedures that we selected are based on EN ISO 13485 and 98/79/EC. 3. TEST PRINCIPLE Vitamin A and vitamin E are extracted from human serum samples using an organic extraction solution after deproteinization step. Separation was made with a isocratic elution on Zivak Vitamin A-E HPLC column and measured by HPLC-UV system. Accuracy and reliability of the analysis could be checked by the serum controls which are supplied with the kit. 4. WARNING AND PRECAUTIONS For in-vitro diagnostic use only. For professional use only. Read the instructions carefully,before you start. In case of damage of the kit package, please contact Zivak or your supplier. Do not use expired kits and components. Please check the batch no and expiry date before start. Although the concentration of all toxic components is low, for safety reasons the sample preparation station should be placed in an exhaust hood. Protective gloves and goggles should be worn. Please take any necessary precautions to prevent infection with blood borne pathogens while working with biological fluids. Appropriate bio-safety precautions and disposal of bio-hazardous wastes should be followed. Please check the labels on reagent bottles. Reagents of this kit contain hazardous material may cause eye and skin irritations. Page 3 / 8

5. STORAGE AND STABILITY This analysis kit can be shipped at room temperature. Reagent 1, MP, WB should be stored at room temperature. Calibrator and controls should be stored at 2-8 C. After arrival, reagent 2, Calibrator and controls (after reconstitution) must be stored at -20 C. All the other components of the kit should be stored at room temperature. Please make sure that you keep reagent 1 at room temperature otherwise it will become unusable. All components are guaranteed until expiry date when stored at recommended temperatures and used as described in these instructions. 6. MATERIALS SUPPLIED ZV-4013-0200-10 Volume Symbol Component ZV-4013-02S1-10 1x 5ml Calibrator Level 1 Lyophilized, Serum Calibrator Level-1 ZV-4013-02K1-10 1x 5ml Control Level 1 Lyophilized, Serum Control Level-1 ZV-4013-02K2-10 1x 5ml Control Level 2 Lyophilized, Serum Control Level-2 ZV-4013-02R1-10 1x 50ml R1 Reagent 1, Contains aqueous buffer ZV-4013-02R2-10 1x 40ml R2 Reagent 2, Contains deuterated internal standart ZV-4013-02WB-10 1x 0,5 L WB Washing Solution ZV-4013-02MP-10 1x 2,5 L MP Mobile Phase, Contains organic solvent ZV-4013-KK-Eng 1x 1pc User Guide 7. MATERIALS REQUIRED BUT NOT SUPPLIED Zivak Vitamin A-E Serum HPLC Analytical Column 200-1000 µl pipette 20-200 µl pipette Pipette tips Vortex mixer 2,0 ml eppendorf tube Eppendorf tube centrifuge Bidistilled or deionised water 0,5 ml conical autosampler vial or vial insert Page 4 / 8

8. PROCEDURE NOTES Any inappopriate handling of samples or modification of the test procedure may influence the results. The indicated pipetting volumes, incubation times, temperatures and pretreatment steps have to be performed strictly according to the instructions. Use calibrated pipettes and devices only. Once the test has been started, all steps should be completed without interruption. Make sure that required reagents, materials and devices are prepared ready at the appropriate time. Leave aside all reagents and specimens to reach room temperature (18-25 C) and gently swirl each vial of liquid reagent and sample before use. Mix reagents without foaming. Avoid contamination of reagents, pipettes and wells/tubes. Use new disposable plastic pipette tips for each reagent, standard or specimen. Do not interchange the vial caps. Always keep vials closed when not been used. Do not re-use wells/tubes or reagents. Incubation time affects results. All tubes or wells should be handled in the same order and time sequences. 9. LIMITATIONS OF THE PROCEDURE Specimen collection and storage have a significant effect on the test results. Serum samples from earlier days must be kept frozen before the analysis. 10. PRE-TEST SETUP INSTRUCTIONS Preparation of Calibrators: Add 5 ml deionized water to serum calibrator and dissolve. After preparation, calibrator must be aliquoted into 250 µl volumes and stored at -20 C. Preparation of Control Level I: Add 5 ml deionized water to Serum Control Level I and dissolve. After preparation, Control Level I must be aliquoted into 250 µl volumes and stored at -20 C. Preparation of Control Level II: Add 5 ml deionized water to Serum Control Level II and dissolve. After preparation, Control Level II must be aliquoted into 250 µl volumes and stored at -20 C. Page 5 / 8

11. TEST PROCEDURE 1. Take 200 L of patient sample (or calibrators and controls) into the sample preparation tube. 2. Add 250 L Reagent 1 and vortex for 10 seconds. 3. Add 200 L Reagent 2 and vortex for 10 seconds. 4. Centrifuge at 12000 x rpm for 3 minutes. 5. Take the upper phase into the autosampler vial. 6. Inject 20 L to the HPLC system. The prepared sample is stable at 2-4 C for 24 hours. 12. QUALITY CONTROL The test results are only valid if the test has been performed by following the instructions. Moreover the user must strictly adhere to the rules of GLP (Good Laboratory Practice) or other applicable standards/laws. All standards and kit controls must be found within the acceptable ranges as stated on the QC Certificate. If the criterias are not met, the run is not valid and should be repeated. Each laboratory should use known samples as further controls. In case of any deviation the following technical issues should be proven: Expiry dates of (prepared) reagents, storage conditions, pipettes, devices, incubation conditions and washing methods. It is recommended to participate at appropriate quality assessment trials. 13. CALCULATION OF RESULTS The obtained area of the standard is plotted against their concentration. The standard curve is calculated by a linear regression or a weighted linear regression function. Using computer programs, the curve is best described by a 1-point linear regression fit with linear axes. For the calculation of the regression curve, apply each signal of the standards (one obvious outlier of duplicates might be omitted and the more plausible single value might be used). The concentration of the samples can be read directly from the regression function. Sample signals above the highest standard have to be confirmed by a reference method. Page 6 / 8

14. INTERPRETATION OF RESULTS Vitamin A: The World Health Organization recommendations supplementation when vitamin A levels fall below 20.0 mcg/dl. Severe deficiency is indicated at levels <10.0 mcg/dl. Vitamin A values >120.0 mcg/dl suggest hypervitaminosis A and associated toxicity. Vitamin E (alpha-tocopherol): -Values that indicate need for supplementation: -Premature: <2.0 mg/l -Neonate: <2.0 mg/l -Child (3 months): <3.0 mg/l -Child (2 years): <3.0 mg/l -Adults: <3.0 mg/l -Values that indicate significant excess: -Adults: >40.0 mg/l Various societies recommend different Cut-Off values for repetition of the measurement and the application of confirmatory assays. Depending on the application of patient samples from different populations, it is highly recommended that each laboratory establishes its own range of normal values and that this distribution of values is co-ordinated with the recommendations of the responsible society of this geographic region. The results themselves should not be the only reason for any therapeutical consequences. They have to be correlated to other clinical observations and diagnostic tests. 15. EXPECTED VALUES VITAMIN A (RETINOL) 0-6 years: 11.3-64.7 mcg/dl 7-12 years: 12.8-81.2 mcg/dl 13-17 years: 14.4-97.7 mcg/dl > or =18 years: 32.5-78.0 mcg/dl VITAMIN E (ALPHA-TOCOPHEROL) 0-17 years: 3.8-18.4 mg/l > or =18 years: 5.5-17.0 mg/l Significant deficiency: <3.0 mg/l Significant excess: >40 mg/l It is recommended that each laboratory establishes its own range of normal values. Page 7 / 8

16. HPLC-UV PARAMETERS Device Zivak ASP-100 HPLC-UV System Column Zivak Vitamin A-E Serum HPLC Analytical Column Injection volume 20 µl Gradient 00.00 min 100% A 08:00 min 100% A Flow 1,20 ml/min Column Oven 30 C Detector UV/VIS Wavelength 00.00-02.00 min 325nm 02:00-08,00 min 295nm 17. ANALYTICAL PERFORMANCE No Analyte LOD (mg/l) LOQ (mg/l) Accuracy (%) Precision (%CV) Linearity (R 2 ) 1 Vitamin A 0.02 0.06 95 3.7 0,999 2 Vitamin E 0.35 1.05 96 4.2 0,998 Analytical Specificity (Cross Reactivity): No cross-reactivities were found with the typical substances tested. 18. SAMPLE CHROMATOGRAM Page 8 / 8