Considerations when treating lung cancer with passive scatter or active scanning proton therapy

Similar documents
8/1/2016. Motion Management for Proton Lung SBRT. Outline. Protons and motion. Protons and Motion. Proton lung SBRT Future directions

Discuss the general planning concepts used in proton planning. Review the unique handling of CTV / ITV / PTV when treating with protons

Proton Beam Therapy at Mayo Clinic

State-of-the-art proton therapy: The physicist s perspective

Treatment Planning (Protons vs. Photons)

Overview. Proton Therapy in lung cancer 8/3/2016 IMPLEMENTATION OF PBS PROTON THERAPY TREATMENT FOR FREE BREATHING LUNG CANCER PATIENTS

Perturbation of water-equivalent thickness as a surrogate for respiratory motion in proton therapy

Range Uncertainties in Proton Therapy

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Hampton University Proton Therapy Institute

Specifics of treatment planning for active scanning and IMPT

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Proton and heavy ion radiotherapy: Effect of LET

Margins in SBRT. Mischa Hoogeman

IN VIVO IMAGING Proton Beam Range Verification With PET/CT

8/3/2016. Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patients. Acknowledgement. Overview

Evaluation of the systematic error in using 3D dose calculation in scanning beam proton therapy for lung cancer

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Image Guided Stereotactic Radiotherapy of the Lung

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

doi: /j.ijrobp

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

Subject: Image-Guided Radiation Therapy

8/3/2016. Clinical Significance of RBE Variations in Proton Therapy. Why RBE (relative biological effectiveness)?

This content has been downloaded from IOPscience. Please scroll down to see the full text.

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

The Harvard community has made this article openly available. Please share how this access benefits you. Your story matters

Mitsubishi Heavy Industries Technical Review Vol. 51 No. 1 (March 2014)

Contour based lung dose prediction for breast proton therapy

On the use of 4DCT derived composite CT images in treatment planning of SBRT for lung tumors

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Treatment Planning for Skull Base Tumors PTCOG 52, June 2013

8/2/2012. Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance. Part II: Thoracic. Peter Balter, Ph.D.

Ion radiography as a tool for patient set-up & image guided particle therapy: a Monte Carlo study

Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Predicting the risk of developing a radiationinduced second cancer when treating a primary cancer with radiation

slide courtesy of Daniel Low Motion management Sofie Ceberg PhD, Medical Physicist Skåne University Hospital, Lund

Advances in external beam radiotherapy

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Dose prescription, reporting and recording in intensity-modulated radiation therapy: a digest of the ICRU Report 83

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Application of Implanted Markers in Proton Therapy. Course Outline. McLaren Proton Therapy Center Karmanos Cancer Institute McLaren - Flint

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

Impact of temporal probability in 4D dose calculation for lung tumors

Electron Beam ET - Reloaded Therapy - Reloaded

Improve dosimetric outcome in stage III non-small-cell lung cancer treatment using spot-scanning proton arc (SPArc) therapy

Potential conflicts-of-interest. Respiratory Gated and Four-Dimensional Tumor Tracking Radiotherapy. Educational objectives. Overview.

I. Equipments for external beam radiotherapy

Radiation qualities in carbon-ion radiotherapy at NIRS/HIMAC

Functional Imaging-guided Radiotherapy for Locally Advanced Non- Small-Cell Lung Cancer: Review

From position verification and correction to adaptive RT Adaptive RT and dose accumulation

Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Automatic Definition of Planning Target Volume in Computer-Assisted Radiotherapy

Cancer Treatment by Charged Particles - Carbon Ion Radiotherapy -

Clinical considerations of RBE in proton therapy

Specification of Tumor Dose. Prescription dose. Purpose

Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom

A comprehensive dosimetric study of Monte Carlo and pencil beam algorithms on intensity modulated proton therapy for breast cancer

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Proton Therapy Dosimetry & Clinical Implementation. Baldev Patyal, Ph.D., Chief Medical Physicist Department of Radiation Medicine

Martin Stuschke 1,2*, Andreas Kaiser 1,2, Jehad Abu Jawad 1, Christoph Pöttgen 1, Sabine Levegrün 1 and Jonathan Farr 2,3

Sarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington

Uncertainties in proton therapy: Analysis of the effects of density changes, calibration curve errors and setup errors in proton dose distributions.

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

Image Guided Proton Therapy and Treatment Adaptation

Evaluation and comparison of New 4DCT based strategies for proton treatment planning for lung tumors

Future upcoming technologies and what audit needs to address

Robust Optimization accounting for Uncertainties

Corporate Medical Policy

8/3/2016. Outline. Site Specific IGRT Considerations for Clinical Imaging Protocols. Krishni Wijesooriya, PhD University of Virginia

AMERICAN BRAIN TUMOR ASSOCIATION. Proton Therapy


Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

A Patient s Guide to SRS

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

The Heidelberg Ion Therapy Center and PARTNER. Thomas Haberer Heidelberg Ion Therapy Center

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Lung tumor motion prediction using data learned offline and during treatment

Intensity Modulated Radiation Therapy (IMRT)

Pitfalls in SBRT Treatment Planning for a Moving Target

MEDICAL MANAGEMENT POLICY

Proton radiotherapy in the treatment of lung cancer

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

New Treatment Research Facility Project at HIMAC

Corporate Medical Policy

Interplay Effect of Target Motion and Pencil-Beam Scanning in Proton Therapy for Pediatric Patients

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Transcription:

Mini-Review Considerations when treating lung cancer with passive scatter or active scanning proton therapy Sara St. James, Clemens Grassberger, Hsiao-Ming Lu Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA Contributions: (I) Conception and design: S St. James; (II) Administrative support: S St. James; (III) Provision of study materials or patients: S St. James; (IV) Collection and assembly of data: S St. James; (V) Data analysis and interpretation: S St. James; (VI) Manuscript writing: All authors; (VII) Final approval of manuscript: All authors. Correspondence to: Sara St. James. Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA. Email: sstjames@mgh.harvard.edu. Abstract: Lung cancer, due to its poor clinical outcomes and significant toxicity associated with standard photon-based radiation, is a disease site that has the potential to greatly benefit from accurate treatment with proton radiation therapy. The potential of proton therapy is the ability to increase the radiation dose to the tumor while simultaneously decreasing the radiation dose to surrounding healthy tissues. For lung cancer treatment, this could mean significant sparing of the uninvolved healthy lung, which is difficult to achieve with external photon beam therapy, or decreasing the heart dose. In treating lung cancer with proton therapy, some additional considerations need to be made compared to treating patients with external photon beam radiation therapy. These include accounting for the finite range of protons in the patient, understanding temporal effects, potential dose discrepancies and choosing an appropriate treatment planning system for the task. One final consideration is differences between the different available proton therapy delivery systems passive scattered proton therapy (PSPT) and active scanning proton therapy. Keywords: Pencil beam scanning proton therapy; proton therapy; treatment planning Submitted Jan 05, 2018. Accepted for publication Mar 28, 2018. doi: 10.21037/tlcr.2018.04.01 View this article at: http://dx.doi.org/10.21037/tlcr.2018.04.01 Proton range In proton therapy, there is a finite range for protons in the patient. The protons stop shortly after the depth of maximum dose deposition this is referred to as the Bragg peak and is illustrated in Figure 1. Due to this finite range in tissue, the delivered dose from proton radiation therapy is more sensitive to density changes, when compared to external beam photon radiation therapy. It is the finite range of the protons in tissue that enables sparing of nearby healthy structures that is not physically possible in external beam photon radiation therapy. It is also this finite range, and the sensitivity of the quality of the treatment plan to perturbations along the beam path, that make treating lung cancers with protons challenging. Treatment planning algorithm considerations One essential component of a successful proton therapy program is the treatment planning system used. Proton treatments in heterogeneous regions have long been known to have larger uncertainties than in homogeneous regions (e.g., lung, supratentorial brain, liver). One consideration is the uncertainty in the range (1). Recommendations have been made to have larger range margins when treating lung (2), which would partly negate the dosimetric benefit of protons. More recently, Monte Carlo simulations of treatment plans have shown that when treating volumes in the lung, the standard pencil beam algorithm in most treatment planning systems is inadequate. The pencil beam algorithm overestimates the dose to the target, and the

Translational Lung Cancer Research, Vol 7, No 2 April 2018 211 patient may in fact receive a lower dose than prescribed (3). Similarly, it also overestimates the range of the protons, and the chosen beams may not cover the entire target. The results of these simulations have been confirmed by end-toend tests; for sites participating in National Cancer Institute (NCI) supported clinical trials on the use of proton therapy for lung cancer, a heterogenous phantom representing a typical thoracic patient is irradiated and the accuracy of the sites ability to treat a volume in a heterogenous volume is determined. Accurate irradiation of this phantom is required if sites wish to enroll patients on clinical trials. An analysis of these phantom irradiations has shown that fewer than 60% of the sites that irradiate the phantom pass the requirements, with pencil beam algorithms over-estimating the dose to the target by up to 46%. When the treatment planning system was changed to a Monte Carlo based system from the standard pencil beam algorithm, disagreements between the measured and predicted doses were resolved. This has resulted in the strong recommendation that when treating in the lung, pencil beam algorithms should never be employed (4). For any type of proton treatment in the lung, dose accuracy is greatly improved if advanced dose calculation algorithms, such as Monte Carlo methods, are used. Patient motion Depth Original water Equivalent Thickness (WET) WET > planned WET WET < planned WET Figure 1 An illustration of the Bragg peak, demonstrating the finite range of the protons in tissue. Slight changes along the path of the proton (e.g., anatomic changes, changes from patient motion) may result in slightly higher or lower WETs. This may result in the protons penetrating further than intended or stopping at a shallower depth than intended. WET, water equivalent thickness. Patient motion is assessed during pretreatment imaging. This can be done through a series of one or more fourdimensional computed tomography (4D-CT) imaging studies. In a 4D-CT the breathing pattern of the patient is monitored and several CT scans are acquired per bed position. When the images are reconstructed, each image is associated with a specific phase or amplitude of the breathing cycle and the tumor trajectory can be visualized through all breathing phases. The internal motion of the tumor can be captured and the magnitude of the motion can be quantified. The 4D-CT is used to characterize the tumor motion due to the patient breathing and this informs the creation of the internal target volume (ITV) (5), from which the treatment plan is generated. From the 4D- CT, other secondary scans can be derived and used in the treatment planning process. In proton therapy treatment planning is typical for the average intensity projection (AIP) image to be used. A conservative approach is for the ITV to be overwritten with Hounsfield units (HUs) slightly denser than water (6) on the AIP. The success of this approach has more recently been evaluated in the active scanning environment, and it was found that applying an over-write of the water equivalent path length (from the beams eye view) in the ITV performed better than a uniform over-ride of the ITV (7). The interplay effects The temporal dependences of the treatment delivery, combined with the breathing motion of the patient have the potential to result in the planned dose and the delivered dose not being in agreement due to the so-called interplay effect. The interplay effect has been studied for many years for complex intensity modulated radiation therapy (IMRT) treatment plans (8,9), for proton double scattering plans (6,10) and, more recently for active scanning treatment plans (11-14). Early geometric studies suggested that dose variations of 10% would be seen due to the interplay effect with scanned proton fields and target motion (15). Fourdimensional Monte Carlo treatment planning studies have been performed to demonstrate that for active scanning systems, ignoring target motion can result in a decrease of dose homogeneity to the target, resulting in a higher maximum dose and a lower minimum dose. In one example, where a patient had a breathing amplitude of 30 mm peakto-peak, the maximum dose to the tumor increased to 140% of the prescribed dose and the minimum dose to the tumor decreased to 44% of the prescribed dose (13). These results were for a single fraction however, and do not include the

212 St. James et al. Considerations for proton therapy treatment of lung cancer effects of averaging over multiple fractions in a conventional treatment regimen. Most studies on the interplay effect ignore baseline shifts. Baseline shifts in breathing, where the patient is breathing deeper or shallower than on the day of simulation, have been reported (16) and shown in simulations to decrease the dose to the clinical target volume (CTV). The dose to the CTV can also be impacted by variations in the patients breathing cycle duration. The dose homogeneity in the presence of baseline shifts and variations in breathing cycle improved with layer repainting and an increase in the number of fractions (17). less than typical breathing cycles. In treatment planning for PSPT, the specific beam angles will be selected (e.g., gantry angle, couch angle) along with an appropriate range and modulation of the spread out Bragg peak to ensure target coverage. The apertures are automatically created with a uniform margin to the target and manually edited if desired. The range compensators are also automatically generated. Once the plan has been completed, the hardware can be fabricated. The hardware fabrication for PSPT necessitates the use of an in-house machinist, materials (brass, Lucite, wax) and the time to fabricate the devices. Proton therapy delivery systems: similarities and differences How the proton field is shaped and directed at the patient can impact the temporal dependence of the delivery. The main equipment dependencies can be considered in one of two main categories for delivery: passively scattered proton therapy and active scanning. A third category, uniform scanning (US), may be thought of as a hybrid of active scanning and passively scattered proton therapy. Historically, all proton therapy centers used double scattering; now, many centers employ active scanning exclusively and the vast majority of new facilities under construction will use active scanning as well. An illustration of the three systems is shown in Figure 2. Passive scattered proton therapy (PSPT) In passive scattering, the proton beam is spread out to be a uniform beam (laterally) through single or double scattering. Single scattering may be used for smaller field sizes to have larger uniform field sizes a double scattering system is required. Most double scattering systems can produce a uniform field distribution for maximum field sizes of up to 25 cm diameter. The edges of the beam can then be shaped laterally by collimators to shape the radiation field that impinges on the patient. A spinning range modulator wheel allows for the beam energy to vary with time and the result is that there is a spread in the energies of the protons, resulting in a dose distribution that is a spread out Bragg peak. The different energies are not all delivered simultaneously, but all of the energies are delivered in a single cycle of the range modulator wheel, which rotates at a typical frequency of 10 Hz. As such, the temporal variance of the delivery of the energies is much Active scanning In active scanning (often called pencil beam scanning or spot scanning) a focused beam of protons of variable intensity and energy is magnetically scanned across the field. The diameter of the individual spots varies as a result of energy, ranging from ~4 mm spot sigma to 10 mm sigma. The shape of the spots is also a function of the beam steering in the system. A good description of active scanning systems can be found in Kooy et al. (18). This scanning technique allows for conformal dose in the lateral directions (x, y) without using additional hardware. Brass apertures are not required for active scanning, as the lateral extent of the treatment field can be maintained by choosing appropriate spot positions. In addition, the ability to control the energy (and therefor the depth of penetration of the protons) results in not needing field specific range compensators and the resulting beams can conform to the proximal and distal shapes of the target. The maximum field size of these systems is up to 30 cm 40 cm. Unlike treatment planning for PSPT, the treatment planning for active scanning is too complex to do without advanced treatment planning systems. For every beam, there are spots of varying weights that can be positioned anywhere within the patient. The complexity of the treatment plan is dealt with by using inverse treatment planning systems where spots are positioned to achieve the required dose to the target and spare nearby organs at risk. In this manner, the treatment planning process closely resembles the treatment planning process for IMRT. Unlike IMRT, there is the additional option to uniformly cover the treatment volume with every beam (single field uniform dose) or to have complimentary fields, where the entirety of the target is covered by the multiple fields in the treatment plan, but not by a unique field in the treatment plan (e.g., multi-field optimization).

Translational Lung Cancer Research, Vol 7, No 2 April 2018 213 Passive scattering Protons Fixed scatterers Range modulator wheel 600 g Magnets (not used) Secondary scatterer Position Resulting beam profile Uniform scanning Protons Fixed scatterers Range modulator wheel (stationary) Magnets (scanning) Position Magnets (scanning) Active scanning Protons Position Figure 2 An illustration of the hardware differences between the three different modalities. For active scanning, the resulting radiation field is the sum of all of the individual spots, which may have different intensity. This is illustrated in the cartoon, with each spot contributing to the total dose (red dashed line). US US is a third modality that is available. In many ways, US may be described as a hybrid of passive scattering and active scanning. In US, protons of a single energy are delivered at one time, as is done in active scanning and the entire energy range is delivered through many (tens) energy layers delivered in one setting. Once one energy layer is delivered, the energy layer is switched and the next energy layer is delivered. Each energy layer reaches a unique maximum depth in the patient and the spacing between the energy layers is determined by the width of the Bragg peak of the previous layer. Energy switching takes 0.5 1.0 second. To achieve a flat field a broad pencil beam (typical spot sigma of 5 cm) is magnetically steered across the entire field of treatment, resulting in a large uniform field. Unlike in the case of active scanning, the beam is not turned off between positions it is continuously scanned across the treatment field at rates of 30 Hz in the fast direction and 3 Hz in the slow direction. As in double scattering, brass apertures to shape the field laterally are required as are range compensators to shape to shape the distal portion of the field. While the proton beam is magnetically scanned in US, the scanning is a constant raster scanning across the entirety of the uniform field size and all lateral beam shaping is done using the brass apertures. An illustration of the three discussed dose delivery options is shown below in Figure 2. Highlighted are the differences in treatment hardware and the direction of the scanning beams. The equipment differences discussed above do not change the dose a stationary tumor receives. In the case of

214 St. James et al. Considerations for proton therapy treatment of lung cancer active scanning, a dosimetric advantage exists because the dose can be more conformal on the proximal and distal ends of the target, better sparing healthy tissues and organs at risk. An additional advantage is the ability to easily create treatment plans of multiple dose levels to different parts of the target volumes, thereby achieving more refined clinical goals. The equipment differences above, do however, result in different temporal variations in how the dose is delivered and may result in dose differences in disease sites with organ motion (e.g., lung, liver). Time dependence of passive scattering, active scanning and US delivery of proton therapy This time dependence is not necessary to consider when patient motion is negligible, but should be considered in treating lung cancers. The three modalities can be ordered from least variable with time to most variable with time. The least time dependent of the three modalities is PSPT. For PSPT, all proton energies are delivered with every rotation of the modulation wheel (0.1 second per rotation). The most time dependent of the three modalities is active scanning where each energy layer is scanned through and then layer-switching pauses (on the order of 1 5 seconds) occur between each energy layer. US falls between the two categories. There is very little time dependence in the lateral direction of the beam (as in PSPT); however, as in active scanning, only one energy layer is delivered at a time and there is an additional pause for energy layer-switching. Motion management There are several strategies for dealing with patient motion. A common approach is to first understand the magnitude of the motion. This can be done through use of a 4D-CT. In many instances, it has been found that motion amplitude greater than 1 cm peak-to-peak is a contraindication for treatment with proton therapy. Once the decision to treat the patient using proton therapy has been made, there are methods to minimize the effects of motion on the dose to the tumor. Two distinct options include (I) gating the delivery of the beam and, in the case of active scanning, (II) layer repainting. Gated delivery In gated delivery, the beam is only on, and radiation is only delivered when the patient is in a predetermined portion of the breathing cycle. The delivered radiation is in synchrony with the patient s breathing on the day of treatment. This requires monitoring the patient during the treatment and the ability to automatically turn the proton beam off and on. For passive scatter proton therapy, this has been implemented (19). For active scanning, gating has been proposed but is not commercially available. Note that gating treatment can also be performed with the patients holding their breath for a short period of time, e.g., 15 25 seconds, if their medical condition allows. Repainting strategies Layer repainting was first suggested as a method to mitigate the interplay effect for active scanning (20). In layer repainting, the dose from a single energy (layer) is broken into multiple equally weighted segments and the energy layer is delivered multiple times. Another repainting strategy proposed is volumetric repainting (21), where the entire field is treated to a dose of 1/N times the desired dose and this is repeated N times. The challenge of managing motion is not unique to proton therapy. For external beam photon therapy, many considerations must also be taken into account when choosing appropriate treatment planning and motion management strategies (22). Conclusions Treating lung cancer using proton therapy has the potential for great dosimetric benefits due to the proximity of nearby healthy organs. Due to the physical characteristics of protons, doses to tumors may be escalated while normal tissue is spared. As a result, proton therapy has the potential to improve patient outcomes. For many disease sites, how the proton fields are shaped and delivered does not impact the quality of the treatment. For lung cancer, and any site where organ motion is a consideration, one must be aware of potential interplay between the motion of the target and the delivery of the radiation field. In proton therapy, as we move towards more complex treatment delivery systems, state of the art treatment planning systems (e.g., Monte Carlo based) will ensure that the designed treatment plan for the patient matches the radiation dose the patient receives.

Translational Lung Cancer Research, Vol 7, No 2 April 2018 215 Acknowledgements None. Footnote Conflicts of Interest: The authors have no conflicts of interest to declare. References 1. Paganetti H. Range uncertainties in proton therapy and the role of Monte Carlo simulations. Phys Med Biol 2012;57:R99. 2. Schuemann J, Dowdell S, Grassberger C, et al. Site-specific range uncertainties caused by dose calculation algorithms for proton therapy. Phys Med Biol 2014;59:4007. 3. Grassberger C, Daartz J, Dowdell S, et al. Quantification of proton dose calculation accuracy in the lung. Int J Radiat Oncol Biol Phys 2014;89:424-30. 4. Taylor PA, Kry S, Followill D. Pencil beam algorithms are unsuitable for proton dose calculations in lung. Int J Radiat Oncol Biol Phys 2017;99:750-6. 5. Wambersie A, Landgerg T. ICRU report 62: prescribing, recording and reporting photon beam therapy. Bethesda, MD: ICRU, 1999. 6. Kang Y, Zhang X, Chang JY, et al. 4D Proton treatment planning strategy for mobile lung tumors. Int J Radiat Oncol Biol Phys 2007;67:906-14. 7. Botas P, Grassberger C, Sharp G, et al. Density overwrites of internal tumor volumes in intensity modulated proton therapy plans for mobile lung tumors. Phys Med Biol 2018;63:035023. 8. Yu CX, Jaffray DA, Wong JW. The effects of intrafraction organ motion on the delivery of dynamic intensity modulation. Phys Med Biol 1998;43:91-104. 9. Seco J, Sharp G, Turcotte J, et al. Effects of organ motion on IMRT treatments with segments of few monitor units. Med Phys 2007;34:923-34. 10. Engelsman M, Rietzel E, Kooy HM. Four-dimensional proton treatment planning for lung tumors. Int J Radiat Oncol Biol Phys 2006;64:1589-95. 11. Seco J, Robertson D, Trofimov A, et al. Breathing interplay effects during proton beam scanning: simulation and statistical analysis. Phys Med Biol 2009;54:N283-94. 12. Bert C, Grözinger SO, Rietzel E. Quantification of interplay effects of scanned particle beams and moving targets. Phys Med Biol 2008;53:2253. 13. Grassberger C, Dowdell S, Lomax A, et al. Motion interplay as a function of patient parameters and spot size in spot scanning proton therapy for lung cancer. Int J Radiat Oncol Biol Phys 2013;86:380-6. 14. Grassberger C, Dowdell S, Sharp G, et al. Motion mitigation for lung cancer patients treated with active scanning proton therapy. Med Phys 2015;42:2462-9. 15. Bortfeld T, Jokivarsi K, Goitein M, et al. Effects of intrafraction motion on IMRT dose delivery: statistical analysis and simulation. Phys Med Biol 2002;47:2203. 16. Shirato H, Suzuki K, Sharp GC, et al. Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumortracking radiotherapy. Int J Radiat Oncol Biol Phys 2006;64:1229-36. 17. Kraus KM, Heath E, Oelfke U. Dosimetric consequences of tumour motion due to respiration for a scanned proton beam. Phys Med Biol 2011;56:6563. 18. Kooy HM, Clasie BM, Lu HM, et al. A case study in proton pencil-beam scanning delivery. Int J Radiat Oncol Biol Phys 2010;76:624-30. 19. Lu HM, Brett R, Sharp G, et al. A respiratory-gated treatment system for proton therapy. Med Phys 2007;34:3273-8. 20. Phillips MH, Pedroni E, Blattmann H, et al. Effects of respiratory motion on dose uniformity with a charged particle scanning method. Phys Med Biol 1992;37:223. 21. Bernatowicz K, Lomax A, Knopf A. Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients. Phys Med Biol 2013;58:7905. 22. Brandner ED, Chetty IJ, Giaddui TG, et al. Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology. Med Phys 2017;44:2595-612. Cite this article as: St. James S, Grassberger C, Lu HM. Considerations when treating lung cancer with passive scatter or active scanning proton therapy. Transl Lung Cancer Res 2018;7(2):210-215. doi: 10.21037/tlcr.2018.04.01