Proton Therapy for Stage IIA-B Seminoma: A New Standard of Care for Treating Retroperitoneal Nodes

Similar documents
Proton Therapy for Stage IIA-B Seminoma: A New Standard of Care for Treating Retroperitoneal Nodes

Testicular cancer radiotherapy

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Specification of Tumor Dose. Prescription dose. Purpose

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

A Case Study: Proton Therapy for Male Breast Cancer with Previous Irradiation

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

Protocol of Radiotherapy for Breast Cancer

TRANS-TASMAN RADIATION ONCOLOGY GROUP INC. Quality Assurance. Treatment Planning Benchmark

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

First, how does radiation work?

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Nordic Society for Gynecological Oncology Advisory Board of Radiotherapy

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

Aytul OZGEN 1, *, Mutlu HAYRAN 2 and Fatih KAHRAMAN 3 INTRODUCTION

Case Scenario 1 Discharge Summary Pathology Report Final Diagnosis: Oncology Consult

New Technologies for the Radiotherapy of Prostate Cancer

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

The Physics of Oesophageal Cancer Radiotherapy

Ashley Pyfferoen, MS, CMD. Gundersen Health Systems La Crosse, WI

Application of asi-kvcbct for Volume Assessment and Dose Estimation: An Offline Adaptive Study for Prostate Radiotherapy

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Case Scenario 1 Discharge Summary Pathology Report Final Diagnosis: Oncology Consult

The New ICRU/GEC ESTRO Report in Clinical Practice. Disclosures

Testicular Malignancies /8/15

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Radiation Therapy for Metastatic Non-Small Cell Lung Carcinoma of the Right Hip

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Doppler ultrasound of the abdomen and pelvis, and color Doppler

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

Potential systematic uncertainties in IGRT when FBCT reference images are used for pancreatic tumors

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Non-Hodgkin s Lymphomas Version

Clinical Commissioning Policy Proposition: Proton Beam Therapy for Cancer of the Prostate

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

Measure the Errors of Treatment Set-Ups of Prostate Cancer Patient Using Electronic Portal Imaging Device (EPID)

Protocol of Radiotherapy for Small Cell Lung Cancer

The Evolution of RT Techniques for Gynaecological Cancers in a developing country context

Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

Intensity Modulated Radiation Therapy for Squamous Cell Carcinoma of the Penis

biij Initial experience in treating lung cancer with helical tomotherapy

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

Defining Target Volumes and Organs at Risk: a common language

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Exercise. Discharge Summary

Trimodality Therapy for Muscle Invasive Bladder Cancer

IMRT for Prostate Cancer

ASTRO econtouring for Lymphoma. Stephanie Terezakis, MD

Margins in SBRT. Mischa Hoogeman

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)

Management preferences following radical inguinal orchidectomy for Stage I testicular seminoma in Australasia

PEDIATRIC ORBITAL TUMORS RADIOTHERAPY PLANNING

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

A dosimetric comparison of proton and photon therapy in unresectable cancers of the head of pancreas

The effect of anterior proton beams in the setting of a prostate-rectum spacer

8/1/2017. Clinical Indications and Applications of Realtime MRI-Guided Radiotherapy

Role of adaptive radiation therapy for pediatric patients with diffuse pontine glioma

Left Chest Wall and Supraclavicular Irradiation Using Photon and Electron Energies

Reducing excess radiation from portal imaging of pediatric brain tumors

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 6, 2016

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

Spinal Cord Doses in Palliative Lung Radiotherapy Schedules

The Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Chapter 2. Level II lymph nodes and radiation-induced xerostomia

SBRT of Lung & Liver lesions using Novalis IGRT System. Patrick Silgen, M.S., DABR Park Nicollet Methodist Hospital

Mesothelioma XRT: From Old School to New School. A brief walk down memory lane at UCLA

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

Bone Marrow Dosimetric Parameters and Hematological Toxicity In Cervical Cancer Patients Undergoing Concurrent Chemoradiation.

Dosimetric consequences of tumor volume changes after kilovoltage cone-beam computed tomography for non-operative lung cancer during adaptive

Department of Radiotherapy & Nuclear Medicine, National Cancer Institute, Cairo University, Cairo, Egypt.

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015

Quiz 1. Assign Race 1, Race 2 and Spanish Hispanic Origin to the following scenarios.

Corporate Medical Policy

Comparison of IMRT and VMAT Plan for Advanced Stage Non-Small Cell Lung Cancer Treatment

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

Role of IMRT in the Treatment of Gynecologic Malignancies. John C. Roeske, PhD Associate Professor The University of Chicago

Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery

BLADDER RADIOTHERAPY PLANNING DOCUMENT

RADIOTHERAPY IN THE MANAGEMENT OF CANCERS OF THE URINARY BLADDER

La Pianificazione e I Volumi di Trattamento

Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413

Transcription:

Proton Therapy for Stage IIA-B Seminoma: A New Standard of Care for Treating Retroperitoneal Nodes Richard Choo, MD 1 ; Bret Kazemba, CMD 1 ; Christopher S. Choo, MD 2 ; Scott C. Lester, MD 1 ; Thomas Whitaker, PhD 1 1 Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA 2 Department of Internal Medicine, University of Minnesota, Minneapolis, MN, USA Abstract Currently there has been no published report describing the use of proton beam therapy for stage II testicular seminoma. A 31-year-old man presenting with a right testicular mass and a 2.7-cm aortocaval lymph node received a diagnosis of stage IIB testicular seminoma. He was treated with scanning proton beam therapy, as a means of improving the therapeutic ratio of radiation therapy over conventionally used x-ray radiation therapy. The patient achieved a complete response and remained free of relapse at 15 months post proton beam therapy. The advantageous dose deposition characteristics of proton beam, allowing much lower radiation doses to normal tissues, should be exploited when radiation therapy is applied for stage II testicular seminoma or for an isolated retroperitoneal lymph node relapse of stage I disease initially managed with surveillance. Keywords: proton beam; stage II seminoma; retroperitoneal lymph nodes Submitted 27 Dec 2017 Accepted 18 Jul 2018 Published 29 Aug 2018 Corresponding author: Richard Choo, MD Department of Radiation Oncology Mayo Clinic 200 First Street SW Rochester, MN 55902, USA Phone: þ1 (507) 284-3551 Fax: þ1 (507) 284-0079 choo.c@mayo.edu Case Report DOI 10.14338/IJPT-18-00001.1 * cc Copyright 2018 International Journal of Particle Therapy Distributed under Creative Commons CC-BY OPEN ACCESS Introduction Testicular seminoma mainly affects young males between the ages of 20 and 45 years, and is highly curable with modern therapies. Over the last 3 decades, major concerns have been raised for potential late treatment-related morbidities, such as a secondary malignancy and an increased risk of cardiovascular disease. As a result, efforts in the management of stage I and II testicular seminoma have been focused on how to improve the therapeutic ratio by minimizing treatment-related toxicity without compromising disease-specific survival. These efforts have led to a steady de-escalation of treatment intensity over time, and surveillance alone with the reservation of radiation therapy or chemotherapy for a relapse has become the standard of care for stage I testicular seminoma. For stage II testicular seminoma with retroperitoneal nodal metastasis, management options include radiation therapy and cisplatin-based combination chemotherapy. For a patient with retroperitoneal nodal metastasis 5 cm (ie, stage IIA and IIB), radiation therapy is a preferred treatment option because it has more favorable side effect profile than combination chemotherapy. When radiation therapy is considered for such patients, proton beam therapy can yield favorable dose deposition characteristics. The adoption of proton beam therapy is consistent with current efforts to continue improving the therapeutic ratio in patients with testicular seminoma, since it can provide a significant reduction in the dose to multiple normal organs that will likely translate into a decreased risk of late radiation-related morbidities, compared to conventional x-ray radiation therapy. http://theijpt.org

Figure 1. (A) Enlarged aortocaval lymph node at presentation. (B) Follow-up of the aortocaval lymph node at 15 months post proton beam therapy. Case Report Medical History A 31-year-old white man, just married 5 months prior, presented with a nontender right testicular mass. A scrotal ultrasonography confirmed a hypoechoic mass in the right testicle. A computed tomography (CT) scan of chest was unremarkable. A CT scan of abdomen and pelvis revealed an enlarged aortocaval lymph node, measuring 1.5 3 1.9 3 2.7 cm (Figure 1A). a-fetoprotein and b human chorionic gonadotropin concentrations were normal. Two months later, he underwent a right radical orchiectomy. Pathology revealed a pure seminoma measuring 1.8 3 1.5 3 1.4 cm. Surgical margins including the spermatic cord margin were clear. There was no rete testis invasion or lymphovascular space involvement. The seminoma was staged IIB. He was advised to undergo definitive radiation therapy for his stage IIB seminoma. Radiation Therapy Plan: Proton versus Photon The patient underwent a CT simulation with 2-mm-slice thickness in the supine position with a vacuum bag device (Civco Inc, Orange City, IA) for the lower legs. There were 2 clinical target volumes (CTVs). The first CTV (CTV1) was contoured around the aorta, inferior vena cava, and ipsilateral iliac vessels with a 7- to 10-mm expansion between the level of the mid-t11 vertebrae and the mid obturator foramen. CTV1 encompassed the periaortic, pericaval, aortocaval, and ipsilateral iliac lymph nodes. The second CTV (CTV2) was to deliver a boost dose to the region of the enlarged node, and contoured in a similar manner. The superior and inferior extent of CTV2 was delineated by using a 20-mm expansion from the involved node. A 5- mm margin (incorporating a 3-mm setup uncertainty and 3% range uncertainty) was then added to the CTV1 and CTV2 to generate optimization target volumes (OTV1 and OTV2) for a proton plan. The same margin was used to create planning target volumes (PTV1 and PTV2) for a comparison photon plan. A proton plan was created by using a single posterior scanning beam (Figure 2A through 2D). A radiation dose of 25.5 Gy(RBE) in 17 fractions was prescribed to the OTV1. This was followed by a boost dose of 10 Gy(RBE) in 5 fractions to the OTV2. Orthogonal kilovoltage imaging was used daily before each fraction to verify alignment of the bony structures (especially the lumbar spine) in relation to the digitally reconstructed radiographs generated from the simulation CT images. In addition, verification CT scans were obtained weekly during the course of proton beam therapy to ensure that the prepared plan would provide adequate coverage of the CTVs and OTVs. No re-planning was needed as each verification scan confirmed satisfactory coverage of the CTVs and OTVs. A 3-dimentional conformal photon plan was prepared with 10-MV beams, using the aforementioned CTVs and PTVs, for comparison. Anterior-posterior and posterior-anterior fields were used with appropriate field weighing (Figure 3A through 3D). Choo et al. (2018), Int J Particle Ther 2

Figure 2. Proton dose distribution in sagittal and 3 axial views: (A) sagittal at mid line, (B) axial at the level of enlarged aortocaval lymph node, (C) axial at 13.4 cm superior to isocenter, and (D) axial at 8.5 cm inferior to isocenter. Table 1. Dose-volume histogram for CTV1 and CTV2: proton versus photon. CTV1 CTV2 Proton Photon Proton Photon Mean, Gy 29.09 a 29.67 a 36.44 36.84 V107%, % 31.6 a 39.5 a 0 0 V100%, % 99.3 95.2 99.7 100 D98%, % 100.5 98.7 100.6 101.3 D95%, % 100.9 100.1 101 101.7 D2%, % 145 a 146.6 a 104.9 105.7 Abbreviation: CTV, clinical target volume. a Owing to the inclusion of CTV2. Choo et al. (2018), Int J Particle Ther 3

Table 2. Dose-volume histogram for organs at risk: proton versus photon. Proton Photon Heart Mean dose, Gy 0 0.56 V5Gy, % 0 0.2 V10Gy, % 0 0 Liver Mean dose, Gy 0.40 3.22 V5Gy, % 2.4 16.2 V10Gy, % 1.5 8.9 V15Gy, % 1 5.5 V20Gy, % 0.6 4.4 V25Gy, % 0.2 1.5 Stomach Mean dose, Gy 0.52 8.40 V5Gy, % 2.9 36.4 V10Gy, % 1.8 29.2 V15Gy, % 1.3 26 V20Gy, % 0.9 23.9 V25Gy, % 0.4 18.2 Large bowel Mean dose, Gy 0.48 8.03 V5Gy, % 3.2 29.4 V10Gy, % 1.3 25.8 V15Gy, % 0.6 23.8 V20Gy, % 0.2 22.5 V25Gy, % 0 19.5 Small bowel Mean dose, Gy 5.54 9.52 V5Gy, % 27.4 36 V10Gy, % 22.5 30.7 V15Gy, % 18.3 27.9 V20Gy, % 14.2 25.7 V25Gy, % 9.2 20.7 V30Gy, % 1.9 5.3 V35Gy, % 0.5 4 V37Gy, % 0.1 1 Rectum Mean dose, Gy 3.07 7.62 V5Gy, % 16.1 31 V10Gy, % 13 24.3 V15Gy, % 10.5 21.1 V20Gy, % 8 18.6 V25Gy, % 3.6 12.9 Pancreas Mean dose, Gy 16.42 24.61 V5Gy, % 84.6 98.8 V10Gy, % 71.5 96.1 V15Gy, % 57.9 94.1 V20Gy, % 44.2 91 Choo et al. (2018), Int J Particle Ther 4

Table 2. Continued. Proton Photon V25Gy, % 27.3 73.2 Bladder Mean dose, Gy 4.91 9.39 V5Gy, % 24 38.4 V10Gy, % 20.6 33.1 V15Gy, % 17.9 29.9 V20Gy, % 14.9 26.4 V25Gy, % 6.5 19 Left testicle Mean dose, Gy 0 0.07 V5Gy, % 0 0 Left kidney Mean dose, Gy 3.04 7.07 V5Gy, % 16 30.8 V10Gy, % 13.4 24.4 V15Gy, % 11.4 19.9 V20Gy, % 8.4 17 V25Gy, % 1.2 5.5 Right kidney Mean dose, Gy 3.10 8.12 V5Gy, % 17.7 36.5 V10Gy, % 13.6 27.7 V15Gy, % 10.5 21.8 V20Gy, % 6.3 17.8 V25Gy, % 1 7.1 Spinal cord Max dose, Gy 21.36 28.16 Mean dose, Gy 9.46 14.57 V5Gy, % 49.6 57.9 V10Gy, % 48.6 53.4 V15Gy, % 47.5 50.1 V20Gy, % 8 49.5 V25Gy, % 0 48.1 Abbreviation: Max, maximum. Dose-Volume Histogram for the Targets and Organs at Risk: Proton versus Photon Plans Both proton and photon plans were created by using identical target dose-volume histogram (DVH) objectives. These included 100% of the CTVs receiving 98% of the prescription dose, and 100% of the OTVs and PTVs receiving 95% of the prescription dose. The DVHs of the targets and organs at risk (OARs) were computed by using the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, California) for both the proton and photon plans. Mean doses and percentage volumes of OAR receiving various doses were calculated and compared between the 2 plans. Both plans provided adequate coverage of the CTVs as well as OTVs and PTVs (Table 1). Table 2 depicts DVH metrics for OARs. The proton plan delivered significantly less doses to the normal tissues, particularly the anterior structures such as the liver, stomach, small bowel, and large bowel. The doses to the kidneys were also reduced with the proton plan. Choo et al. (2018), Int J Particle Ther 5

Figure 3. Photon dose distribution in sagittal and 3 axial views: (A) sagittal at mid line, (B) axial at the level of enlarged aortocaval lymph node, (C) axial at 13.4 cm superior to isocenter, and (D) axial at 8.5 cm inferior to isocenter. Follow-up The patient completed proton beam therapy without any treatment interruption and experienced only self-limiting minimal nausea (grade 1, based on Common Terminology Criteria for Adverse Events v4.0). At the 15-month follow-up evaluation, a CT scan of the chest, abdomen, and pelvis showed that the enlarged lymph node remained completely resolved (Figure 1B) with no evidence of nodal or distant metastasis. His laboratory results including b human chorionic gonadotropin and a- fetoprotein, and physical examination, were also normal. He was considered in complete remission. His wife was 12 weeks pregnant, and they conceived without using sperms banked before the radiation therapy. Discussion Radiation therapy with the reservation of combination chemotherapy for the salvage of post radiation therapy relapse has been the mainstay for the management of stage IIA-IIB testicular seminoma. The CTV includes the periaortic, pericaval, aortocaval, and ipsilateral iliac lymph nodes, and the irradiation field typically encompasses the region from the superior endplate of the T11 vertebrae down to the middle of the obturator foramen. Choo et al. (2018), Int J Particle Ther 6

Given that patients with testicular seminoma usually receive a diagnosis at a young age and live long after treatment with a very high cure rate, the major concern for these patients has been the potential late sequelae of treatment, such as radiationrelated secondary malignancies. Therefore, recent efforts have focused on reducing treatment-related toxicity while preserving a high rate of cure. Such efforts have included the decrease in radiation dose and field size as well as the adoption of surveillance as the preferred management strategy for stage I testicular seminoma. Another such strategy is the utilization of proton beam radiation therapy instead of conventional x-ray radiation therapy, when radiation therapy is indicated, given the more favorable dose deposition characteristics of proton beam therapy. There has been a single case report describing the utilization of proton beam therapy for a patient who experienced a relapse in a pericaval lymph node after being initially managed with surveillance [1]. A few other reports assessing proton beam therapy were dosimetric studies describing the rationales for using proton beam therapy in patients with stage I and II seminoma [2 4]. This case report illustrates that proton beam therapy provides adequate coverage of CTVs while significantly limiting the collateral dose to the surrounding normal organs. This dose reduction should translate into less acute side effects and reduced risk of late complications such as secondary malignancies. Potential acute side effects of radiation therapy include nausea, diarrhea, fatigue, and decreased blood counts. Theses side effects can be reduced significantly with proton beam therapy (in particular, with a single posterior beam arrangement), as it allows a significant decrease in the dose to normal organs such as the liver, stomach, small bowel, large bowel, and pancreas. In our case, V5Gy (%) to V25Gy (%) as well as mean doses of all the gastrointestinal organs, both kidneys, and bladder were reduced with proton beam therapy. Expected decreases in gastrointestinal side effects and radiation therapy related lethargy portend a less adverse impact on quality of life and a higher likelihood of maintaining occupational or academic productivity. One of the most concerning late side effects of radiation therapy is radiation-induced secondary cancers. Several studies evaluated and quantified this risk. Travis et al [5] reported that for patients with a diagnosis of seminoma at the age of 35 years, the cumulative risk of solid cancer 40 years later was 36% compared with an expected 23% for the general population; further, about 64% of solid tumors occurred within the irradiated field. As demonstrated in this case report, proton beam therapy can significantly reduce the dose to adjacent organs including the stomach, pancreas, small bowel, large bowel, rectum, and bladder. This dramatic dose reduction achieved with proton beam therapy should translate into lower rates of late radiation complications, including second malignancies, in seminoma survivors. Other advantages of proton beam therapy include a reduced dose to the heart, which should translate into a decreased risk of cardiovalvular, cardiomuscular, and cardiovascular toxicity. Another advantage is a potential to decrease the dose to the remaining testis. Given that fertility issue can be a major concern for young men and that the testicular germinal epithelium is highly sensitive to radiation, reducing a dose to the remaining testis is an important aspect of overall treatment strategy. Since the proton beam penumbra in the lateral direction is smaller than that of conventional x-ray, it can reduce the dose to the remaining testis, which can translate into better preservation of spermatogenesis. In conclusion, this case report presents a clinical and dosimetric rationale for using proton beam therapy for a patient with stage IIB seminoma. Proton beam radiation therapy improves the therapeutic ratio of radiation therapy with a notable reduction in the dose to multiple normal organs that should translate into reductions in the acute and late side effects of radiation therapy. Thus, when radiation therapy is indicated for patients with stage IIA-IIB, proton beam therapy should be strongly considered as a standard of care to maximize survival and quality of life. ADDITIONAL INFORMATION AND DECLARATIONS Conflicts of Interest: The authors have no conflicts of interest to disclose. References 1. Haque W, Wages C, Zhu XR, Choi S, Pugh TJ, Frank SJ, Lee A, Mahmood U. Proton therapy for seminoma: case report describing the technique, efficacy, and advantages of proton-based therapy for seminoma. Pract Radiat Oncol. 2015;5: 135 40. 2. Simone CB II, Kramer K, O Meara WP, Bekelman JE, Belard A, McDonough J, O Connell J. Predicted rates of secondary malignancies from proton versus photon radiation therapy for stage I seminoma. Int J Radiat Oncol Biol Phys. 2012;82: 242 9. Choo et al. (2018), Int J Particle Ther 7

3. Hoppe BS, Mamalui-Hunter M, Mendenhall NP, Li Z, Indelicato DJ. Improving the therapeutic ratio by using proton therapy in patients with stage I or II seminoma. Am J Clin Oncol. 2013;36:31 7. 4. Efstathiou JA, Paly JJ, Lu HM, Athar BS, Moteabbed M, Niemierko A, Adams JA, Bekelman JE, Shipley WU, Zietman AL, Paganetti H. Adjuvant radiation therapy for early stage seminoma: proton versus photon planning comparison and modeling of second cancer risk. Radiother Oncol. 2012;103:12 7. 5. Travis LB, Fossa SD, Schonfeld SJ, McMaster ML, Lynch CF, Storm H, Hall P, Holowaty E, Andersen A, Pukkala E, Andersson M, Kaijser M, Gospodarowicz M, Joensuu T, Cohen RJ, Boice JD Jr, Dores GM, Gilbert ES. Second cancers among 40,576 testicular cancer patients: focus on long-term survivors. J Natl Cancer Inst. 2005;97:1354 65. Choo et al. (2018), Int J Particle Ther 8