SURGERY OF THE HAND INTRODUCTION CASE REPORT. Hee-June Kim 1, Hyun-Joo Lee 1, Dong-Hyun Kim 1, Joon-Woo Kim 1, Ji Won Oh 2

Similar documents
Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture

엄지의수근중수관절염에의한장무지신건의특발성파열 : 증례보고

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture

Acute Rupture of Flexor Digitorum Profundus Tendon Associated with Distal Radius Fracture: A Case Report

Intratendinous Ganglion of the Extensor Digitorum Tendon

SURGERY OF THE HAND. Basosquamous Carcinoma of the Hand in a Radiologist with Prolonged Radiation Exposure INTRODUCTION CASE REPORT CASE REPORT

Intrinsic muscles palsies of the hand Management of Thumb Opposition with BURKHALTER s Procedure

Bilateral Trans-Scaphoid Perilunate Fracture Dislocation

Emile N. Brown, MD, and Scott D. Lifchez, MD

The Importance of Preoperative Imaging Study on a Solitary Neurofibroma Originated from the Digital Nerve

Classification of Established Volkmann s Ischemic Contracture and the Program for Its Treatment

AJO needle, and compartment pressures were measured

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Physical therapy of the wrist and hand

Ultrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation

Wrist & Hand Ultrasonography 대구가톨릭대학교병원재활의학과 권동락

Identification of Double Compression Lesion of Ulnar Nerve after Cubital Tunnel Release

Clinical examination of the wrist, thumb and hand

Institute of Reconstructive Surgery, Sofia, Bulgaria

A New Examination Method for Anatomical Variations of the Flexor Digitorum Superficialis in the Little Finger

Simultaneous Bilateral Patellar Tendon Ruptures Associated with Osteogenesis Imperfecta

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

Manual Kirschner-Wire Insertion through the Soft Tissue for Finger Immobilization after Scar Contracture Release

Distal Radius Plate 2.4/2.7 dorsal and volar

MCQWeek2. All arise from the common flexor origin. The posterior aspect of the medial epicondyle is the common flexor origin.

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures.

Kinesiology of The Wrist and Hand. Cuneyt Mirzanli Istanbul Gelisim University

Distraction Arthroplasty of the Trapeziometacarpal Joint Without Trapeziectomy

Revisiting the Curtis Procedure for Boutonniere Deformity Correction

Wrist Fusion Instrument and Implant Set.

De Maeseneer et al. Sonography of the Extensor Pollicis Longus Tendon

SURGERY OF THE HAND. Synovial Chondromatosis of the Ulnocarpal Joint INTRODUCTION CASE REPORT CASE REPORT. Sung-Guk Kim

I-A-1) Non-specific thickening of synovial membrane

Lecture 9: Forearm bones and muscles

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

MR: Finger and Thumb Injuries

Wrist & Hand Assessment and General View

Heterotopic Ossification of the Elbow after Medial Epicondylectomy

Ultrasonography of the wrist - a step-by-step approach to study protocols and normal findings

Introduction to Ultrasound Examination of the Hand and upper

Trapezium is by the thumb, Trapezoid is inside

SURGERY OF THE HAND. Reverse Digital Island Flap with Skin Strip Retention to Prevent Flap Congestion INTRODUCTION ORIGINAL ARTICLE

Main Menu. Wrist and Hand Joints click here. The Power is in Your Hands

Management of Hand Palsies in Isolated C7 to T1 or C8, T1 Root Avulsions

Muscles of the hand Prof. Abdulameer Al-Nuaimi

Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study

Index. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI /

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Drop hand treated with modified jones transfer

Acu-Loc Wrist Plating System. Surgical Technique

The Muscular System. Chapter 10 Part C. PowerPoint Lecture Slides prepared by Karen Dunbar Kareiva Ivy Tech Community College

Wrist and Hand Anatomy

Correction of Long Standing Proximal Interphalangeal Flexion Contractures with Cross Finger Flaps and Vigorous Postoperative Exercises

SURGERY OF THE HAND. Results of Iliac Bone Graft with Kirschner Wire Fixation for Scaphoid Nonunions INTRODUCTION ORIGINAL ARTICLE

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

SURGERY OF THE HAND. Atypical Presentation of Subungal Melanoma INTRODUCTION CASE REPORT. Seung Hwan Hwang, Sujin Bahk, SuRak Eo

A Comparative Study on Tendon Transfer Surgery in Patients with Radial Nerve Palsy

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Results of Abductor Pollicis Longus Suspension Ligamentoplasty for Treatment of Advanced First Carpometacarpal Arthritis

Wrist and Hand Complaints

SURGERY OF THE HAND. Nodular Melanoma on the Tip of the Thumb INTRODUCTION CASE REPORT. Su Hyun Choi, Hong Bae Jeon, Ja Hea Gu

LCP Wrist Fusion Set. Anatomic plates for total wrist fusion.

Hand injuries. The metacarpal bones may fracture through the base, shaft or the neck.

Humeral shaft fractures usually occur in young

Difference Between Angle You Can Bend Your Left Wrist Back vs Your Right Wrist Jenna Priest Science Department Altoona High School January 25, 2017

Tendon Transfers. Variability muscle 2x stronger than another Greatest force at resting length. Drag:

Levels of the anatomical cuts of the upper extremity RADIUS AND ULNA right

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

Urgent Cases and Foreign Bodies

Nerves of Upper limb. Dr. Brijendra Singh Professor & Head Department of Anatomy AIIMS Rishikesh

The Effect of Distal Location of the Volar Short Arm Splint on the Metacarpophalangeal Joint Motion

SCAHPO-LUNATE DISSOCIATION

Acute Wrist Injuries OUCH!

Interesting Case Series. Swan-Neck Deformity in Cerebral Palsy

Hand and wrist emergencies

분절성쇄골골절의수술적치료와비수술적치료 - 증례보고 -

Case Report Bone Resection for Isolated Ulnar Head Fracture

Ultrasonography of Peripheral Nerve -upper extremity

SPECIAL ARTICLE. Missed tendon injuries INTRODUCTION

Hand and Wrist Editing file. Color Code Important Doctors Notes Notes/Extra explanation

Chang-Hyuk Choi, M.D., Se-Sik Kim, M.D., Won-Jun Chang, M.D.*, and Hee-Soo Kim, M.D.

Acu-Loc Wrist Spanning Plate System. Surgical Technique

E arly rupture of the ex t en s or pollici s long u s t endon af ter f racture of the di s tal end of the radiu s - A c as e report -

The Forearm 2. Extensor & lateral Compartments of the Forearm

Musculoskeletal Imaging of the Digits. Arash David Tehranzadeh, MD UCSD MSK Radiology May 11 th, 2006

WINSTA-R. Distal Radius System

The hand is full with sweat glands, activated at times of stress. In Slide #2 there was a mistake where the doctor mentioned lateral septum twice.

Fractures and dislocations of the fingers

Tendon involvement in the rheumatoid hand

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Interesting Case Series. Posterior Interosseous Nerve Compression

SURGERY OF THE HAND. Double Minimal Incision Release for Carpal Tunnel Syndrome: A Comparative Study to the Standard Open Technique INTRODUCTION

Volar Wrist Ganglion: A Report of an Unusual Case. Eyad Alqasim, MD* Rashid Kameshki, MBBS** Maged Mostafa, MD***

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

31yo M with chronic basilar thumb and wrist pain that started after cross-country bicycle ride 5 yrs ago.

Treatment of unstable distal radius fractures with the volar locking plate

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

Transcription:

CASE REPORT pissn 1598-3889 eissn 2234-0998 J Korean Soc Surg Hand 2017;22(3):202-207. http://doi.org/10.12790/jkssh.2017.22.3.202 JOURNAL OF THE KOREAN SOCIETY FOR SURGERY OF THE HAND Extensor Pollicis Longus Tendon Rupture with Concomitant Rupture of the Extensor Digitorum Communis II Tendon and Extensor Indicis Proprius after Volar Plating for Distal Radius Fracture Hee-June Kim 1, Hyun-Joo Lee 1, Dong-Hyun Kim 1, Joon-Woo Kim 1, Ji Won Oh 2 1 Department of Orthopaedic Surgery, Kyungpook National University Hospital, Kyungpook National University School of Medicine, Daegu, Korea 2 Department of Anatomy, Kyungpook National University School of Medicine, Daegu, Korea Extensor tendon rupture is well known complication following distal radius fracture after either conservative treatment or volar plating. However, there are not many reports in literature about concomitant ruptures of other extensor tendons. We report a case of delayed rupture of extensor pollicis longus (EPL), second extensor digitorum communis (EDC II), and extensor indicis proprius (EIP) tendons 4 weeks after volar plating for distal radius fracture. Due to the absence of EIP, EIP transfer was discouraged for EPL reconstruction. Thumb and index finger extension was restored by palmaris longus tendon graft for EPL and EDC II. Received: April 9, 2017 Revised: [1] June 19, 2017 [2] July 10, 2017 Accepted: July 19, 2017 Correspondence to: Hyun-Joo Lee Department of Orthopedic Surgery, Kyungpook National University Hospital, Kyungpook National University School of Medicine, 130 Dongduk-ro, Jung-gu, Daegu 41944, Korea TEL: +82-53-200-5628 FAX: +82-53-422-6605 E-mail: hjleeleehj@gmail.com Keywords: Distal radius fracture, Volar plating, Extensor pollicis longus, Extensor digitorum communis II, Extensor indicis proprius, Tendon rupture This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/ 3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. INTRODUCTION Extensor pollicis longus tendon (EPL) rupture is a known and well-described complication of distal radius fracture, with the incidence ranging from 0.2% to 4% 1,2. Causes hypothesized for the rupture include sharp bony spike, protruded screw, or local lengthening of extensor tendon compartment 1,3,4. Common extensor rupture has also been described as a complication of distal radius fracture, after either surgical or conservative treatment 3-6. 202 http://www.jkssh.org/ Copyright c 2017. The Korean Society for Surgery of the Hand

Hee-June Kim, et al. Multiple Extensor Tendons Rupture Fig. 1. Axial and three-dimensional computed tomography images demonstrating a fracture of Lister s tubercle on the right side (arrows). A bony spur created a the gap between the fragment and the main radius part and might be the cause for tear of the tendon. However, reports on concomitant rupture of other extensor tendons are rare 3,5,6. We report a case of delayed rupture of EPL, second extensor digitorum communis (EDC II), and extensor indicis proprius (EIP) tendons due to impingement between the bony cleft, 4 weeks after volar plating for distal radius fracture. CASE REPORT A 50-year-old man admitted to our emergency department following a motorcycle accident and intraarticular fractures in both distal radii (23-B2, AO/OTA classification) were detected. The computed tomography (CT) scan of right hand showed extension of the fracture line to the Lister s tubercle (Fig. 1). Open reduction and internal fixation using a variable-angle locking compression plate distal radius plate (DePuy Synthes, Zuchwil, Switzerland) was performed using the volar Henry approach, 1 week after the trauma (Fig. 2). However, 4 weeks after surgery, the patient visited the outpatient clinic and complained of extension limitation of the right thumb and index finger (Fig. 3). The passive range of movement of the thumb and index finger was not affected. On ultrasonography, complete disruptions Fig. 2. Preoperative and postoperative plain radiography showed that the fracture gap of the Lister s tubercle persisted. of the EPL and second extensor tendons were observed with a 7-cm defect (Fig. 4). Though, EIP showed continuity on ultrasonography, the patient could not extend his index finger independently. Therefore, EIP transfer was discouraged, and a palmaris longus (PL) graft was more recommened. The right PL appeared intact during the thumb-little finger opposition test, but the left PL was not http://www.jkssh.org/ 203

J Korean Soc Surg Hand Vol. 22, No. 3, September 2017 Fig. 3. In the physical examination, limitations in thumb interphalangeal and index metacarpophalangeal joint extensions were observed when compared with those on the normal side. Fig. 4. Axial image of ultrasonography showed complete disruptions of the extensor pol licis longus, (solid arrow) and fracture gap of Lister s tubercle (vacant arrow). Fig. 5. The ruptures of the extensor pollicis longus (arrowhead), extensor indicis proprius (solid arrow), and extensor digitorum communis II (vacant arrow). The asterisk shows a bony spur near Lister s tubercle. prominent and covered with a scar from a previous suicide attempt. A curvilinear incision was made on the original course of the EPL tendon, centering the Lister s tubercle and damage of the extensor retinaculum around the third and fourth extensor compartments was confirmed. On examination of The EPL and index extensors, attritional rupture of the EIP and EDC II was confirmed at the fourth extensor compartment on the dorsum of the wrist, with a defect of about 7-cm. Granulation tissue and tear were observed around the ruptured margin. The EPL tendon was also impaired and almost ruptured, but attached with a string-like fibrotic tissue. The proximal part of the ruptured EPL was displaced to the radial side from the third compartment and was held in place by peripheral fibrotic tissue. The cause of the tendon rupture was investigated. No screw protrusion was found, but a prominent Lister s tubercle and a fracture gap on the ulnar side of the tubercle were observed. A portion of the demaged tendon remnant was located between the bony cleft (Fig. 5). After removal of the protruding bone spur, it was necessary to cover the fracture site on the Lister s tubercle, to prevent tendon injuries. Hence, the tendon sheath and periosteum around the second compartment were pulled to the ulnar side and sutured to the remaining tendon sheath and periosteum of the third compartment (Fig. 6). Subsequently, PL tendons were harvested from both sides of the wrist. After adequate preparation of the PL tendon, EPL and EDC II were reconstructed from using 204 http://www.jkssh.org/

Hee-June Kim, et al. Multiple Extensor Tendons Rupture the PL tendons using the Pulvertaft technique (Fig. 7). A short-arm cast with the wrist and thumb extended, was applied for 5 weeks and following which, active flexion and extension increased progressively. Ten months later, Fig. 6. After removing the bony protrusion, the surrounding soft tissue was pulled to the ulnar side and sutured to the remaining tendon sheath and periosteum of the 3rd compartment to prevent further tendon tear (solid arrow). Fig. 7. EPL (solid arrow), and EDC II (vacant arrow) were reconstructed with the PL tendons using the Pulvertaft technique. EPL, extensor pollicis longus; EDC II, extensor digitorum communis; PL, palmaris longus. the interphalangeal joint of the thumb and the metacarpophalangeal joint of the index finger had no limitation of flexion, while an extension lag of 20 remained (Fig. 8). DISCUSSION De Boer et al. 5 reported case of EPL rupture with EDC II tendon rupture occurred following a distal radius fracture, treated with a cast, However, rupture of three tendons after volar plate fixation of a distal radius fracture has been rarely reported in the literature 3,6. The cause of rutpure in our case was thought to have been caused by the friction and impingement of the tendon in the third and fourth extensor compartments in the bone cleft, which had a fragment of the Lister s tubercle and the main fragment rather than the volar plating itself. Although EIP transfer is the most commonly used technique for reconstructing the ruptured EPL, with concominant index extensor rupture like in our case. PL, or other tendon free grafts might be the first choice to restore the joint function. In case with multiple-tendon rupture, in which conventional tendon transfer cannot be performed, various options should be considered before performing surgery. Alternative transfers to EPL include extensor pollicis brevis, extensor carpi radialis and a slip of abductor pollicis longus 7. Tendon grafting requires two tendon repair sites and it is difficulty to overcome the myostatic contracture for appropriate tensioning 8, Tendon grafting also permits one to perform at least three Fig. 8. After 10 months, the interphalangeal joint of the thumb and the metacarpophalangeal joint of the index finger showed a persistent 20 of extension lag (the flexion photograph was not taken). http://www.jkssh.org/ 205

J Korean Soc Surg Hand Vol. 22, No. 3, September 2017 weaves with the stump of the EPL tendon by using the Pulvertaft technique, thus, diminishing the chance of a spontaneous dehiscence at the tendon juncture. However, Pulvertaft technique is not applicable to the extensor carpi radialis longus or another possible transfer due to its shorter reach 9. Hence, tendon transfer had to be considered as a secondary options. Chung et al. 10 also reported that both tendon grafting and tendon transfer are reliable reconstruction methods for ruptured finger extensor tendons in rheumatoid hands. Furthermore, the patient refused to sacrifice the normal functional tendons; hence, we decided to perform tendon graft using PL. For patients with distal radius fracture and extensor tendon rupture, multiple tendon injury should be considered and thorough preoperative examination that includes imaging studies must be performed. This information will help in the decision-making process regarding the appropriate reconstruction method and surgical planning. CONFLICT OF INTEREST No potential conflict of interest relevant to this article was reported. REFERENCES 1. Roth KM, Blazar PE, Earp BE, Han R, Leung A. Incidence of extensor pollicis longus tendon rupture after nondisplaced distal radius fractures. J Hand Surg Am. 2012;37:942-7. 2. Tarallo L, Mugnai R, Zambianchi F, Adani R, Catani F. Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events. J Orthop Trauma. 2013;27:740-5. 3. Ward JP, Kim LT, Rettig ME. Extensor indicis proprius and extensor digitorum communis rupture after volar locked plating of the distal radius: a case report. Bull NYU Hosp Jt Dis. 2012;70:273-5. 4. Hattori Y, Doi K, Sakamoto S, Yukata K. Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture. Hand Surg. 2008;13:183-5. 5. de Boer SW, van Kooten EO, Ritt MJ. Extensor pollicis longus tendon rupture with concomitant rupture of the extensor digitorum communis II tendon after distal radius fracture. J Hand Surg Eur Vol. 2010;35:679-81. 6. Caruso G, Vitali A, del Prete F. Multiple ruptures of the extensor tendons after volar fixation for distal radius fracture: a case report. Injury. 2015;46 Suppl 7:S23-7. 7. Gelb RI. Tendon transfer for rupture of the extensor pollicis longus. Hand Clin. 1995;11:411-22. 8. Hamlin C, Littler JW. Restoration of the extensor pollicis longus tendon by an intercalated graft. J Bone Joint Surg Am. 1977;59:412-4. 9. Thoma A, Quttainah A. Extensor indicis proprius tendon transfer for extensor pollicis longus rupture. Can J Plast Surg 2001;9:139-42. 10. Chung US, Kim JH, Seo WS, Lee KH. Tendon transfer or tendon graft for ruptured finger extensor tendons in rheumatoid hands. J Hand Surg Eur Vol. 2010;35:279-82. 206 http://www.jkssh.org/

Hee-June Kim, et al. Multiple Extensor Tendons Rupture 원위요골골절의배측금속판고정술시행후발생한장무지신근건의파열과동반된총수지신근및시지신근의파열 김희준 1 이현주 1 김동현 1 김준우 1 오지원 2 1 경북대학교병원정형외과학교실, 2 경북대학교의과대학해부학교실 신전건의파열은원위요골골절의보존적치료나수장측금속판고정후에발생할수있는합병증으로잘알려져있다. 그러나신전건의다발성파열은보고된사례는많지않아원위요골골절로수장측금속판고정술을시행한뒤 주후에발생한장무지신근, 총수지신근 II, 시지신근의지연성파열증례에대해보고하고자한다. 시지신근의파열로장무지신근의재건술은불가능하여, 장무지신근과총수지신근 II 각각을양측장장근을이용한이식술로복원하였다. 색인단어 : 원위요골골절, 수장측금속판고정, 장무지신근, 총수지신근 II, 시지신근, 건파열 접수일 2017 년 4 월 9 일수정일 1 차 : 2017 년 6 월 19 일, 2 차 : 2017 년 7 월 10 일게재확정일 2017 년 7 월 19 일교신저자이현주대구광역시중구동덕로 130 경북대학교병원정형외과학교실 TEL 053-200-5628 FAX 053-422-6605 E-mail hjleeleehj@gmail.com http://www.jkssh.org/ 207