and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7].

Similar documents
Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

a Centre de Médecine Cardiovasculaire, Paris, France, b Lebanese Hospital and Received 7 June 2009 Revised 15 September 2009 Accepted 9 October 2009

Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension

DR JIRAR TOPOUCHIAN PROF PAROUNAK ZELVEIAN PROF ROLAND ASMAR. September 8 th, Principal Investigator and Study Chair:

1. Department of Gynecology and Obstetrics, St. Joseph's Hospital Berlin Tempelhof, Germany

Methods DEVICES AND TECHNOLOGY

Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home. blood pressure monitoring according to the European Society of Hypertension

Unreliable oscillometric blood pressure measurement: prevalence, repeatability and characteristics of the phenomenon

Received 10 April 2008 Revised 23 June 2008 Accepted 24 June 2008

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

a Medical Physics Department, Guy s & St Thomas NHS Foundation Trust and b King s College School of Medicine, St Thomas Campus, London, UK

Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

DEVICES AND TECHNOLOGY

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and

1 Department of Medical Physics, Royal Infirmary of Edinburgh, 2 Department of. Received 11 June 2004 Accepted 7 September 2004

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard

Validation Study Result Form

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

The increasing awareness of hypertension as a serious

Comparison of the Microlife A2 Basic (BP3GQ1-3P) with the Microlife BP3BT0-A and Microlife BP A100 Plus

Home blood pressure measurement with oscillometric upper-arm devices

Copyright: DOI link to paper: Date deposited: This work is licensed under a Creative Commons Attribution 2.5 Generic License

Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients?

Device Equivalence Evaluation Form

a ARSMED (Association for Research and Development of Biomedical Received 11 October 2007 Revised 27 March 2008 Accepted 27 March 2008

Validation Study Result Form

Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation

Device Equivalence Evaluation Form

Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation

Maker Spacelabs Healthcare Manufacturer Spacelabs Healthcare. Brand Spacelabs Model OnTrak

Device Equivalence Evaluation Form

Comparison of the Microlife A6 PC (BP3GU1-8Y) with the Microlife BP3BT0-A and Microlife BP A100 Plus

Comparison of manual versus automated blood pressure measurement in intensive care unit, coronary care unit, and emergency room.

AFFORDABLE TECHNOLOGY

Device Equivalence Evaluation Form

greater than 90% of patients having blood pressure measured consistently according to the protocol.

There is convincing evidence in clinical studies

Special articles from the ESH working group on blood pressure monitoring 23

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE. MEASURING BLOOD PRESSURE - MANUAL (equ04)

Clinical Evaluation of an Oscillometric NIBP Technology During Hemodialysis According to the British Hypertension Society Protocol

In clinical practice, blood pressure (BP) treatment

THE NEW ARMENIAN MEDICAL JOURNAL DISTRIBUTION, AWARENESS, TREATMENT, AND CONTROL OF ARTERIAL HYPERTENSION IN YEREVAN (ARMENIA)

Declaration of Equivalence Form

Device Equivalence Evaluation Form

Copyright: DOI link to article: Date deposited: This work is licensed under a Creative Commons Attribution 4.0 International License

When the BHS dissolved its Working Party on Blood Pressure Measurement, the Working Group on Blood

Does Talking and Different Body (Sitting, Supine, Standing) Positions affect Blood Pressure?

Device Equivalence Evaluation Form

Ambulatory blood pressure monitoring (ABPM) is. Accuracy of Ambulatory Blood Pressure Monitors in Routine Clinical Practice.

!"#$ Blood Pressure Monitor. Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

A GUIDE TO OUR NIBP TECHNOLOGY

HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER

M1 Classic. Digital Blood Pressure Monitor. Instruction manual page 1 SYS. mmhg DIA. mmhg. PULSE/min

MX3 Plus English. Introduction. Table of contents. 1 How to obtain meaningful blood pressure readings

THE ACCURATE ASSESSMENT

BRIEF COMMUNICATIONS. KEY WORDS: Ambulatory blood pressure monitoring, placebo effect, antihypertensive drug trials.

The introduction of oscillometric automated blood pressure

2. Measure a subject's blood pressure and heart rate both at rest and during exercise.

Blood Pressure Competency Training

Received 24 February 2015 Revised 29 April 2015 Accepted 20 May 2015

Device Equivalence Evaluation Form

The measurement of blood pressure and hypertension. Handout Fenyvesi Tamás III.Department of Medicine

Céline Guggiari a, Christophe Büla a, Katia Iglesias b and Bernard Waeber b,c

Validation Study Registration Form

boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals

a Hypertension Center, Third University Department of Medicine, Sotiria Hospital,

Validity study of oscillometric blood pressure measurement devices using an oscillometric waveform simulator

Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination

Arm position and blood pressure: a risk factor for hypertension?

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

STATE OF THE ART BP ASSESSMENT

EUROPEAN SOCIETY OF HYPERTENSION GUIDELINES FOR THE USE OF HOME BLOOD PRESSURE MONITORING. A SUMMARY REPORT OF THE

Mercury versus Non-Mercury Sphygmomanometers: A Review of the Comparative Clinical Effectiveness and Guidelines

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN?

Automatic oscillometric blood pressure devices are frequently

White coat and masked hypertension

CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME

The Value of a BP Determination Method Using a Novel Non-Invasive BP Device against the Invasive Catheter Measurement

Validation of Missouri Aneroid Sphygmomanometer to Measure Blood Pressure in Patients with Cancer

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION*

RESEARCH INTRODUCTION

PLANK 1 Direct Care Staff Trained in Accurate BP Measurement

DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Home monitoring of blood glucose

SIGNAL PROCESSING and KNOWLEDGE ACQUISITION in OBJECTIVE BLOOD PRESSURE MEASUREMENT with CONVENTIONAL CLINICAL SPHYGMOMANOMETRY

LEARNING OUTCOME The students will be able to elicit vital signs correctly on human volunteers/patients

External Oscillatory Blood Pressure - EOBPTM

Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls

High Blood Pressure Blood Pressure Monitoring at Home -- F...

Managing Blood Pressure: It Takes a Team

THE EFFECT OF CLOTHES ON SPHYGMOMANOMETRIC BLOOD PRESSURE: COMPARISON OVER SLEEVED ARM VERSUS UNSLEEVED (BARE) ARM

Device Judgement Recommended

Assessment of techniques for measurement of blood pressure in infants and children

Assessing Blood Pressure Accuracy of an Aneroid Sphygmomanometer in a National Survey Environment

An Automated System for Blood Pressure Determination During Exercise

European Society of Hypertension Practice Guidelines for home blood pressure monitoring

Transcription:

Devices and technology 37 Validation of the A&D UM-11 professional hybrid device for office blood pressure measurement according to the International Protocol George S. Stergiou, Periklis P. Giovas, Charilaos P. Gkinos and Dimitris G. Tzamouranis Objective Assessment of the accuracy of the A&D UM-11 mercury-free professional device for auscultatory blood pressure (BP) measurement according to the European Society of Hypertension International Protocol. Further to auscultation, the device has a button to mark readings during deflation. Methods Fifteen adults were included in phase 1 and another 18 in phase 2. Simultaneous BP measurements were taken by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements using the tested device (two connected tested devices, one used with and the other without the mark button). Results In phase 1, the device produced 44/4/4 measurements within /1/1 mmhg, respectively, for systolic BP (SBP) and 39/43/4 for diastolic (DBP). In phase 2.1, 87/97/99 measurements within /1/1 mmhg, respectively, for SBP, and 91/97/99 for DBP (using the mark button 6/93/98 for SBP and 76/96/99 for DBP). In phase 2.2, 29 participants had at least two of their SBP differences within mmhg and none had any differences within mmhg, whereas 32 and none, respectively, for DBP (with mark 24/4 participants for SBP; 29/1 for DBP). Mean SBP differences were 1. ± 3. mmhg and DBP 1.3 ± 3. (with mark 3.6 ± 4.2 and 2.8 ± 3.7). The difference in SBP measured by the tested device with versus without using the mark button was 3. ± 3.3 mmhg (P <.1) and DBP 1.9 ± 2. mmhg (P <.1). Conclusion The device comfortably passed the validation protocol requirements. Using the mark button, the device, however, failed to meet the validation criteria. Therefore, it is recommended for clinical use without using the mark button. Blood Press Monit 13:37 42 c 28 Wolters Kluwer Health Lippincott Williams & Wilkins. Blood Pressure Monitoring 28, 13:37 42 Keywords: accuracy, European Society of Hypertension, hybrid sphygmomanometer, International Protocol, office blood pressure, professional device, validation Third University Department of Medicine, Hypertension Center, Sotiria Hospital, Athens, Greece Correspondence to George S. Stergiou, MD, Hypertension Center, Third University Department of Medicine, Sotiria Hospital, 12 Mesogion Avenue, Athens 1127, Greece Tel: + 3 21 776 3117; fax: + 3 21 771 9981; e-mail: gstergi@med.uoa.gr Received 1 February 27 Revised 7 March 27 Accepted 9 March 27 Introduction Aiming to environmental protection, mercury is progressively being banned from medical use in several European countries [1,2]. The conventional mercury sphygmomanometer, however, is still regarded as the gold standard for blood pressure (BP) measurement against which any new device should be tested for its accuracy [3 6]. Electronic monitors that measure BP using the oscillometric principle have dominated the market of ambulatory and home monitoring [6,7]. Still no agreement on what will replace the mercury device for the conventional office measurement [3,7], however, exists. The increasing list of electronic devices that satisfy the currently accepted accuracy criteria [8] suggests that the oscillometric technology for BP measurement is advancing. Automated oscillometric manometers have the additional advantage that avoid the observer prejudice 139-237 c 28 Wolters Kluwer Health Lippincott Williams & Wilkins and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7]. It should be mentioned, however, that the currently used protocols for device validation accept a significant level of inaccuracy to be present. For example, according to the International Protocol of the European Society of Hypertension Working Group on Blood Pressure Monitoring [9], an accurate monitor might have a BP difference greater than mmhg from the reference measurement (using a mercury sphygmomanometer) in 39 of 99 comparisons, a difference greater than 1 mmhg in 24 of 99 and greater than 1 mmhg in nine of 99 comparisons. In addition, for a monitor that fulfills the validation requirements, the protocol allows one out of three participants to have one of their three BP comparisons with a greater than mmhg difference from

38 Blood Pressure Monitoring 28, Vol 13 No 1 the reference measurement and three of 33 participants with all their three comparisons greater than mmhg [9]. Despite these relatively undemanding criteria, only few oscillometric devices have succeeded to pass the International Protocol [7 9]. It appears that, at present, the currently accepted accurate oscillometric monitors might be inadequate as a replacement of the professional mercury sphygmomanometer. An interesting proposal for a professional device alternative to the mercury sphygmomanometer is the socalled hybrid sphygmomanometer [3,4,6], which has a vertical liquid crystal display (LCD) that resembles a conventional mercury column and works using the auscultatory technique by an observer. The device has the potential to eliminate the terminal digit preference through the use of a button that marks systolic (SBP) and diastolic blood pressure (DBP) readings on the LCD display during cuff deflation. This paper presents the results of a validation study of the A&D UM-11 (A&D Company, Ltd., Toshima Ku, Tokyo, Japan), which is a mercury-free professional device that has the features of a hybrid sphygmomanometer, according to the European Society of Hypertension International Protocol for Validation of Blood Pressure Measuring Devices in Adults [9]. Methods Tested device The A&D UM-11 (A&D Company, Ltd) is a mercuryfree device for professional use by the physician in the office or clinic using the auscultatory BP measurement. The device has a vertical LCD display that resembles a conventional mercury column, a standard bulb to inflate the cuff manually and a button for the observer to mark the systolic and diastolic readings on the LCD display during cuff deflation. It allows measurements of BP at a range between and 3 mmhg using the auscultatory method by an observer. In addition, it automatically measures pulse rate during deflation at a range between 3 and 2 beats/min and indicates the value on a numerical display in the end of each measurement. This numerical display also shows the level of cuff pressure as it is progressively reduced during deflation. It is powered by two 1.-V batteries. Three cuffs are available to be used with the device: small cuff (for arm circumference 17 cm), standard (23 33 cm) and large cuff (33 4 cm). The dimensions of the device are similar to those of a conventional mercury sphygmomanometer (96 66 322 mm) and its weight is 94 g without batteries. Two devices were obtained from the local distributor for the purpose of the study together with a written declaration that they were standard production models. Familiarization session To familiarize themselves with the tested device and particularly with the use of the mark button, the investigators took multiple practice BP measurements in a busy hypertension clinic for a period of 3 weeks. During this phase, it was suspected that the use of the mark button might affect the accuracy of BP measurement. Therefore, a modification of the International Protocol was deemed necessary to allow a separate validation of the device, with and without using the mark button. Blood pressure measurements One supervisor and two trained observers experienced in the methodology of BP measurement were involved in this validation study. The observers were retested for agreement in BP measurement according to the British Hypertension Society protocol [1] before the study initiation. Two standard mercury sphygmomanometers (Riester, diplomat-presameter, Rud. Riester GmbH Co. KG, Jungingen, Germany), the components of which have been carefully checked before the study, and a Littman teaching stethoscope were used for simultaneous (Y tube) observer-taken reference BP measurements. The supervisor measured BP with the tested device without using the mark button, and also checked the agreement of BP measurements taken by the two observers who were blinded from each other s readings. To assess the function of the mark button of the device, the tested device used by the supervisor was connected with a second device of the same type (Y tube), which was simultaneously used by one of the observers in random order (again using a Littman teaching stethoscope), always using the mark button (supervisor without using the mark button versus observer using the mark button). For all measurements taken using the tested device, both the observers and the supervisor exclusively used the vertical LCD column to record BP. Observer readings with a difference greater than 4 mmhg were repeated until closer agreement was reached. Two cuffs of the tested device (normal and large) were used for all measurements taken using the tested and the mercury device according to the manufacturer s instructions to fit the arm circumference of each individual. All measurements were taken on the left arm, which was supported at heart level. The protocol was approved by the hospital scientific committee. Participants According to the International Protocol, in phase 1 a total of 1 treated or untreated participants are included who fulfill the age, sex and entry BP range requirements (age 3 years or older, at least five men and five women, five participants with entry BP within each of the ranges 9 129 mmhg, 13 16 mmhg and 161 18 for SBP and 4 79 mmhg, 8 1 mmhg and 11 13 mmhg for DBP). If analysis of these data is successful, additional

Office manometer validation Stergiou et al. 39 participants are recruited until a total of 33 participants fulfill the age, sex and entry BP range requirements for phase 2 (age 3 years or older, at least 1 men and 1 women, 11 participants with entry BP within each of the abovementioned BP ranges for SBP and DBP). Participants with sustained arrhythmia or irregular pulse during the validation procedure were excluded. Written informed consent was obtained from all participants who participated in the study. Procedure The validation study was conducted in an isolated room where disturbing noise was avoided. Age, sex and arm circumference of each participant was recorded, together with the cuff size used and the date and time of the validation procedure. After 1 1-min sitting rest, BP was measured by the two observers (entry BP). This measurement was used to classify participants into the low, medium and high range, separately for SBP and DBP, as described above. Device detection measurement followed by the supervisor, to ensure that the device was able to measure BP of each individual. The two observers took readings BP1, BP3, BP and BP7 using the double-headed stethoscope and the mercury sphygmomanometers. The supervisor took readings BP2, BP4 and BP6 using the test device without using the mark button. The validation analysis was based on the last seven measurements (BP1 BP7). As mentioned above, for each of the measurements taken by the supervisor using the tested device, a simultaneous measurement was obtained using a second device of the same type (Y tube connected) by one of the observers in random order, always using the mark button. This approach allowed the application of the International Protocol criteria for the assessment of the accuracy of the device twice: (a) without using the mark button (readings BP2, BP4, BP6 taken by the supervisor) and (b) by using the mark button (readings taken by the observers simultaneously with BP2, BP4, BP6). Analysis Each pair of observer measurements was averaged and was then subtracted from the device measurement. The absolute differences between BP2 BP1, BP2 BP3, BP4 BP3, BP4 BP, BP6 BP and BP6 BP7 were calculated and paired according to the device reading. For each pair, the one with the smaller difference was used in the analysis. These BP differences were classified into three zones (within, 1 and 1 mmhg), separately for SBP and DBP, for 1 participants in phase 1 and for all the 33 in phase 2.1. For each individual participant, the number of readings with a difference within mmhg was also calculated (phase 2.2). To assess the accuracy of the device using the mark button, the analysis of phase 2 was repeated after replacing the supervisor s measurements (BP2, BP4, BP6) with the simultaneous measurements taken by the observers using the second tested device and the mark button. In addition, simultaneous BP readings taken by the supervisor and the observers using the tested devices (with versus without using the mark button) were compared using paired t-tests. Statistical analysis was performed using the MINITAB INC Statistical Software (release 13.31) (Stage College, Pennsylvania, USA). Results Study participants A total of 38 participants were recruited from an Outpatients Blood Pressure Clinic and from ambulatory patients and staff of a University Department of Medicine. To facilitate the recruitment procedure, emphasis was placed to recruit participants with high diastolic and low SBP first, and those with high systolic and low diastolic later, as recommended by the International Protocol [9]. One participant was initially excluded because his entry BP was out of the range required for study inclusion and was included later in the study after treatment modification. No participant was excluded due to arrhythmia. In seven BP readings there was a difference between the observers measurements greater than 4 mmhg. These were repeated to reach closer agreement. The first 1 participants (4 BP readings), who fulfilled the International Protocol criteria regarding sex and systolic and diastolic entry BP range, were included in the analysis of phase 1. Analysis of phases 2.1 and 2.2 was based on the first 33 participants (99 BP readings), who fulfilled the study inclusion criteria regarding sex and entry BP. The characteristics of participants in study phase 1 and 2 are presented in Table 1. The standard cuff was used in 29 of the 33 participants and the large one in the remaining four. Validation criteria The use of the tested device was straightforward and there were no operational problems during the study. Table 1 Characteristics of participants in study phase 1 and 2 Participants (men/women) Mean age ± SD years Mean arm circ ± SD cm Entry SBP ± SD mmhg Entry DBP ± SD mmhg Phase 1 1 (7/8) 4.7 ± 9.9 (32 6) 28.9 ± 3.4 (24 36) 14.7 ± 27.3 (99 177) 88.7 ± 16.4 (62 111) Phase 2 33 (16/17) 48.7 ± 13.6 (31 83) 28. ± 3.3 (23 36) 14.4 ±.3 (99 177) 88. ± 1.8 (62 11) Arm circ, arm circumference; DBP, diastolic blood pressure; SBP, systolic blood pressure.

4 Blood Pressure Monitoring 28, Vol 13 No 1 Table 2 Results of the validation analysis (in parentheses results using the mark button of the tested device) Phase 1 r mmhg r 1 mmhg r 1 mmhg Recomm. Mean diff. SD Required One of 3 4 achieved SBP 44 4 4 Continue.9 2.6 DBP 39 43 4 Continue 1.2 3.8 Phase 2.1 r mmhg r 1 mmhg r 1 mmhg Recomm. Mean diff. SD Required Two of 6 8 9 All of 6 7 9 achieved SBP 87 (6) 97 (93) 99 (98) Pass 1. ( 3.6) 3. (4.2) DBP 91 (76) 97 (96) 99 (99) Pass 1.3 ( 2.8) 3. (3.7) Phase 2.2 2/3 r mmhg /3 r mmhg Recomm. Required Z 22 r 3 Achieved SBP 29 (24) (4) Pass (Fail) DBP 32 (29) (1) Pass (Pass) DBP, diastolic blood pressure; SBP, systolic blood pressure; Recomm, Recommendation; Mean diff, mean difference. The requirements of the International protocol for phases 1, 2.1 and 2.2 and the results of the validation analysis are presented in Table 2. The differences in BP between the observer readings and the tested device without using the mark button (99 readings) are presented in Fig. 1 and those obtained using the mark button in Fig. 2. In phase 1, the tested device passed all the three criteria (one required), for both SBP and DBP (Table 2). The mean BP differences between the tested device and the reference method were.9 ± 2.6 mmhg for SBP and 1.2 ± 3.8 mmhg for DBP. In phase 2.1, the device comfortably satisfied all the six criteria (five required), for both SBP and DBP (Table 2). The performance of the device significantly deteriorated by using the mark button, yet the device fulfilled the requirements of phase 2.1 (Table 2, numbers in parentheses). The mean BP differences between the device and the reference method in all the 33 participants were 1. ± 3. mmhg for SBP and 1.3 ± 3. mmhg for DBP. Using the mark button these differences were 3.6 ± 4.2 and 2.8 ± 3.7 for SBP and DBP, respectively. In phase 2.2, the device also passed all the protocol criteria for SBP and DBP. Using the mark button the device, however, marginally failed to fulfill the protocol criteria for SBP (Table 2). The mean difference between simultaneous measurements taken by the supervisor (using the tested device without pressing the mark button) and those taken by the observers (using the second tested device and the mark button) was 3. ± 3.3 mmhg (9% confidence intervals 2.4, 3.7; P <.1) for SBP and 1.9 ± 2. mmhg (9% confidence intervals 1.4, 2.4; P <.1) for DBP. Discussion This study provides information on the accuracy of the A&D UM-11 professional mercury-free device for auscultatory BP measurement. The study showed that the device comfortably passes all the validation requirements of the International Protocol, provided that it is used by well-trained observers without using the mark button. In fact, the device appeared to be nearly perfect and more accurate than recently validated oscillometric devices [8]. On the other hand, when using the device button to mark the systolic and diastolic readings on the LCD display, the accuracy of the device significantly deteriorated and the device failed to satisfy the phase 2.2 criteria. The A&D UM-11 professional device is a challenging mercury-free simulation of the conventional mercury sphygmomanometer that remains the gold standard for accurate BP measurement. Apart from addressing the environmental issue with mercury toxicity, the A&D UM-11 has the potential to eliminate another important drawback of the conventional mercury sphygmomanometer. This is due to the use of the auscultatory technique, which is known to be subject to the terminal digit preference and the observer bias [7]. By using a button to mark on the LCD display the BP values, the observer bias might be eliminated. These features of the device (LCD display and mark button) are those of the so called hybrid device [3,4,6]. Unfortunately, the reaction time needed for the observer to press the button appeared to have a significant impact on the device accuracy and resulted in systematic underestimation of BP. This drawback was realized by the investigators during the prestudy familiarization

Office manometer validation Stergiou et al. 41 Fig. 1 Fig. 2 Device observer measurement (mmhg) Device observer measurement (mmhg) 3 SBP 2 1 1 1 8 9 1 11 12 13 14 1 16 17 18 19 3 DBP 2 1 1 1 3 4 6 7 8 9 1 11 12 13 14 Scatterplots presenting differences in blood pressure between the observer readings and the tested device used without the mark button (99 readings). Recruitment limits regarding entry blood pressure ranges (low, medium and high) are indicated by the vertical lines DBP, diastolic blood pressure; SBP, systolic blood pressure. Device observer measurement (mmhg) Device observer measurement (mmhg) 3 SBP 2 1 1 1 8 9 1 11 12 13 14 1 16 17 18 19 3 DBP 2 1 1 1 3 4 6 7 8 9 1 11 12 13 14 Scatterplots presenting differences in blood pressure between the observer readings and the tested device used with the mark button (99 readings). Recruitment limits regarding entry blood pressure ranges (low, medium and high) are indicated by the vertical lines DBP, diastolic blood pressure; SBP, systolic blood pressure. phase and the study design was modified to allow the assessment of the device accuracy with and without using the mark button. As the reaction time is known to increase with age, the performance of the tested device using the mark button is expected to deteriorate if used by physicians older than the study observers (age of observers was 32 3 years) [11]. In conclusion, the A&D UM-11 device used by welltrained observers and the auscultatory technique comfortably passed the validation requirements of the International Protocol. The use of the device button to mark the readings, however, resulted in a significant underestimation of BP. Therefore, the A&D UM-11 device without using the mark button provides an excellent solution for professional mercury-free BP measurement, but has the drawbacks of the auscultatory technique, such as the observer bias and the terminal digit preference. Acknowledgement This work was funded by the Hypertension Center, Third Department of Medicine, University of Athens, Greece. References 1 O Brien E. Demise of the mercury sphygmomanometer and the dawning of a new era in blood pressure measurement. Blood Press Monit 23; 8:19 21. 2 O Brien E. Has conventional sphygmomanometry ended with the banning of mercury? Blood Press Monit 22; 7:37 4. 3 Pickering TG. What will replace the mercury sphygmomanometer? Blood Press Monit 23; 8:23. 4 Pickering T. The case for a hybrid sphygmomanometer. Blood Press Monit 21; 6:177 179.

42 Blood Pressure Monitoring 28, Vol 13 No 1 23 European Society of Hypertension. European Society of Cardiology guidelines for the management of arterial hypertension. J Hypertens 23; 21:111 13. 6 Pickering T, Hall J, Appel L, Falkner B, Graves J, Hill M, et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension ; 4:142 161. 7 O Brien E, Asmar R, Beilin L, Imai Y, Mancia G, Mengden T, et al. On behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. European Society of Hypertension Recommendations for Conventional, Ambulatory and Home Blood Pressure Measurement. J Hypertens 23; 21:821 848. 8 dabls Educational Trust: Devices for blood pressure measurement. http://www.dableducational.org. Assessed 4 February 27. 9 O Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al. with the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 22; 7:3 17. 1 O Brien E, Petrie J, Littler WA, de Swiet M, Padfield PL, Altman D, et al. The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11(Suppl 2): S43 S63. 11 Fozard J, Vercryssen M, Reynolds S, Hancock P, Quilter R. Age differences and changes in reaction time: the Baltimore Longitudinal Study of Aging. J Gerontol 1994; 49:179 189.