Determination of Polydextrose in Foods by AOAC Method

Similar documents
Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Determination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

Determination of Sucralose in Reduced- Carbohydrate Colas using High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection

Sialic Acid Determination in Glycoproteins: Comparison of Two Liquid Chromatography Methods. Experimental. Introduction. Method 1.

HPAE-PAD Determination of Infant Formula Sialic Acid

Determination of Sucralose Using HPAE-PAD

autosamplers ASI-100 and ASI-100T Autosamplers

Determination of Plant-Derived Neutral Oligo- and Polysaccharides

Ion Chromatography: A Versatile Technique for the Analysis of Beer

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Determination of Ethyl Sulfate Impurity in Indinavir Sulfate Drug Using Ion Chromatography

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

Glycoprotein monosaccharide analysis using HPAE-PAD with manually prepared eluent

A HPAE-PAD Chromatographic Assay for Carbohydrates in Urine as a Measure of Intestinal Permeability

Direct Determination of Sialic Acids in Glycoprotein Hydrolyzates by HPAE-PAD

Determination of Lactose in Lactose-Free Milk Products by High-Performance. anion-exchange chromatography with. Pulsed Amperometric Detection

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Sugars in Honey Using HPAE-PAD: What Is the Best Column?

Mercury Speciation Determinations in Asian Dietary Supplements

Rapid determination of phosphate and citrate in carbonated soft drinks using ion chromatography

ASSAY OF using AZO-FRUCTAN S-AZFR5 11/17

Thermo Scientific Dionex CarboPac MA1 Column

CarboPac PA-100 Column for Oligosaccharide Analysis

Rapid Determination of Phosphate and Citrate in Carbonated Soft Drinks Using a Reagent-Free Ion Chromatography System

Technical Note 55. Screening of Sample Matrices and Individual Matrix Ingredients for Suitability in AAA-Direct INTRODUCTION

Determination of Carbohydrates in Beverages and Milk Products by HPAE-PAD and Capillary HPAE-PAD

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

ARABINAN

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

columns CarboPac PA20 Column

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

ab Lipid Peroxidation (MDA) Assay kit (Colorimetric/ Fluorometric)

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

Sugar analysis according to the EU Regulation using amperometric detection and Metrosep Carb 2-150/4.0

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Relative Measurement of Zeaxanthin Stereoisomers by Chiral HPLC

Separation of Chromium (III) and Chromium (VI) by Ion Chromatography

EASIMIP TM PATULIN Product Code: P250 / P250B

LACTOSE/ SUCROSE/D-GLUCOSE

Nitrate/Nitrite Assay Kit Manual Catalog #

Determination of Carbachol In Ophthalmic Solutions Using a Reagent-Free Ion Chromatography System

Key Words Dionex CarboPac PA200, Prebiotics, Probiotics, Disposable Electrode, Carbohydrates, Infant Formula

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

MIXED XYLANASE, β-glucanase ENZYME PREPARATION, produced by a strain of HUMICOLA INSOLENS

ASSAY OF USING BETA-GLUCAZYME TABLETS

Direct Determination of Native N-linked Glycans by UHPLC with Charged Aerosol Detection

Mono- and Disaccharides

GLUCOSE OXIDASE

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

AZO-XYLAN (BIRCHWOOD)

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

AZO-WHEAT ARABINOXYLAN

Oligosaccharide Analysis by High-Performance Anion- Exchange Chromatography with Pulsed Amperometric Detection

ab65336 Triglyceride Quantification Assay Kit (Colorimetric/ Fluorometric)

CORESTA Recommended Method No. 85

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

endo-1,4-beta-xylanase

Determination of Bisphenol A in Milk Powder using a Chromolith HighResolution RP-18 endcapped column

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

TECHNICAL BULLETIN METHOD 1: DETERMINATION OF TOTAL DIETARY FIBRE

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary.

AMYLOGLUCOSIDASE from ASPERGILLUS NIGER, var.

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

CORESTA Recommended Method No. 78

HPLC Analysis of Sugars

1 out of 8. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 86th Meeting 2018 ERYTHROSINE

10 Sulfaquinoxaline H N O S O. 4-amino-N-quinoxalin-2-ylbenzenesulfonamide C 14 H 12 N 4 O 2 S MW: CAS No.:

Rapid Quantitative Analysis of Cannabidiol from Consumer Products Using UltraPerformance Convergence Chromatography

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

Glucose 6 Phosphate Assay Kit (Colorimetric)

ANTEC LEYDEN. Analysis of Carbohydrates in Food and Beverages using Anion-Exchange Chromatography and Pulsed Amperometric. Introduction.

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

SACCHARIDES (Liquid Chromatography)

Rapid Screening of Sialic Acids in Glycoproteins by HPAE-PAD

Lutein Esters from Tagetes Erecta

CORESTA RECOMMENDED METHOD N 8

Analysis of L- and D-Amino Acids Using UPLC Yuta Mutaguchi 1 and Toshihisa Ohshima 2*

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

Fig.1. Denatonium benzoate (DB) chemical structure

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Application Note 178 INTRODUCTION

ALPHA-AMYLASE ASSAY PROCEDURE (AMYLASE SD METHOD)

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Determination of Methacholine Chloride and Potential Impurities Using a Reagent-Free Ion Chromatography System

Transcription:

Application Note 147 Determination of Polydextrose in Foods by AOAC Method 2000.11 INTRODUCTION Polydextrose is a synthetic polymer of glucose having mainly α1,6 linkages and an average degree of polymerization of 12. This oligosaccharide is recognized as dietary fiber in several countries, including Japan. Unfortunately, existing methods to measure dietary fiber do not measure polydextrose. To overcome this limitation, Stuart et al. 1 developed a method based on high-performance anion-exchange chromatography with pulsed amperometric detection (HPAE-PAD) to measure polydextrose in foods. The authors organized a successful AOAC collaborative study of this method and it was approved as AOAC Method 2000.11. 2 Polydextrose is separated on a CarboPac TM PA1 column and detected by PAD using a triple-potential waveform (Waveform B, Dionex Technical Note 21 3 ). A quadruple-potential waveform (Waveform A, Technical Note 21) provides greater long-term reproducibility on peak area response compared to Waveform B. 4 During our participation in the Method 2000.11 collaborative study, we analyzed samples with both waveforms. This application note shows that Waveform A produced results equivalent to those obtained with Waveform B. Using Waveform A instead of B for Method 2000.11 and other HPAE-PAD methods will yield equivalent results and greater long-term peak area reproducibility. EQUIPMENT Chromatography Equipment Dionex BioLC chromatography system consisting of: GP50 Gradient Pump with vacuum degas option ED50 Electrochemical Detector E01 Eluent Organizer AS50 Autosampler with Thermal Compartment Chromeleon 6 Chromatography Workstation Other Equipment Microcentrifuge (Centriguge 5415 C, Eppendorf) Vortex mixer (Vortex-Genie 2, VWR Products) Water bath (preferably two) (Model 1202, VWR Products) Analytical centrifuge capable of 6000 g (a Spinchron R [Beckman] was used for this study) REAGENTS AND STANDARDS Deionized water, 17.8 MΩ-cm resistivity or better (used for all eluent and standard preparations) Sodium hydroxide, 50% (w/w) (Fisher Scientific) Sodium acetate, anhydrous (Fluka, Microselect) Polydextrose (available at health food stores) Fructanase, 667 U/mL (Megazyme or equivalent) Amyloglucosidase, 3260 U/mL (soluble starch) (Megazyme E-AMGDF or equivalent) Isoamylase, 200 U/mL (Megazyme E-ISAMY or equivalent) Application Note 147 1

Other Consumables Autosampler vials (0.5 ml, Dionex P/N 055428) Microcentrifuge tubes (1.7 ml, Sarstedt) 0.2 µm syringe filters (PTFE, 13 mm diameter, Gelman Sciences) Ultrafiltration centrifuge tubes 2 ml tubes with 100,000 dalton cutoff, polyethersulfone membrane (e.g. Millipore Ultrafree CL PBHK BIOMAX-100) CONDITIONS Column: CarboPac PA1 Analytical, (4 250 mm, P/N 35391) CarboPac PA1 Guard (4 50 mm, P/N 43096) Expected Operating Pressure: 9.7 MPa (1400 psi) Temperature: 30 C Degas: 30 sec every 10 min Inj. Volume: 25 µl Injection Loop: 100 µl Detection: Pulsed amperometry, gold working electrode, Ag/AgCl reference Collection Rate: 2 Hz Expected Background: 20 37 nc Needle height: 2 mm Cut segment Volume: 4 µl Flush volume: 400 µl Gradient Eluent A: 150 mm sodium hydroxide Eluent B: 150 mm sodium hydroxide/0.5m sodium acetate Flow Rate: 1.2 ml/min Time (min) %A %B 0.0 70 30 10.0 70 30 10.1 0 100 15.0 0 100 15.1 70 30 25.0 70 30 Autosampler Cycle Time: 26 min Table 1. ED50 Waveforms for Carbohydrate Analysis Time (sec) Waveform A Potential 0.00 +0.1 0.00 +0.05 0.20 +0.1 Begin 0.20 +0.05 Begin 0.40 +0.1 End 0.40 +0.05 End 0.41 2.0 0.41 +0.75 0.42 2.0 0.60 +0.75 0.43 +0.6 0.61 0.15 0.44 0.1 1.00 0.15 0.50 0.1 Integration (V) Time (sec) Waveform B Potential Integration (V) Note: Waveform A should only be used with a new gold working electrode or a gold working electrode that has only been used with this waveform. 3 PREPARATION OF SOLUTIONS AND REAGENTS Buffered Enzyme Mix Dissolve the content of the fructanase bottle (8000 U) in 12 ml of a sodium acetate buffer (ph 4.5). Prepare this buffer by mixing 28 ml of 0.2 M acetic acid with 22 ml of 0.2 M sodium acetate and then bring this solution up to 100 ml with water. Combine 2 ml fructanase, 84 µl amyloglucosidase, and 84 µl isoamylase, and bring to a final volume of 20 ml with the acetate buffer. This mixture is stored at 4 C and is prepared on the day of use. STANDARD PREPARATION The study organizers provided the polydextrose standard. Polydextrose can be purchased at health food stores. The stock standard is 5000 mg/l and is prepared by weighing approximately 500 mg into a preweighed glass container with screw cap (record weight) and adding 100 g of water preheated to 80 C. Vortex and incubate in an 80 C water bath until the polydextrose is dissolved. Weigh the container after allowing the solution to cool to room temperature. Prepare the eight intermediate standards by diluting the stock standard to 2500, 2000, 1500, 1250, 1000, 750, 500, and 250 mg/l. These standards are diluted during the standard and sample preparation procedure that follows to yield working standards of 500, 400, 300, 250, 200, 150, 100, and 50 mg/l. 2 Determination of Polydextrose in Foods by AOAC Method 2000.11

SAMPLE PREPARATION This section has a brief summary of the sample preparation procedure outlined in AOAC Method 2000.11. For more detail, please consult the method. 2 The study organizers provided blind duplicate samples of six food products: milk chocolate candy, iced tea, sugar cookie, grape jelly, soft jellied candy, and a powdered drink mix, as well as blind duplicate samples of polydextrose. Food samples are cut or ground into small particles. If the approximate amount of polydextrose in the sample is known, choose a sample weight within the range of the working standards. This study used 0.5 g of the milk chocolate candy, 5 g of the iced tea, 2 g of the sugar cookie, 2 g of the grape jelly, 0.5 g of the soft jellied candy, and 5 g of the powdered drink mix solution (the dry sample provided was first dissolved in 8 oz water). Add each sample to a preweighed glass container with screw cap and then record the weight. Add 100 g of hot (80 C) water. Cap the container and treat the same as the standards were treated to dissolve the polydextrose. Weigh the capped vial after allowing it to cool to room temperature. Treat samples and standards as follows: Pipet 2 ml of solution (freeze the remaining solution) into an ultrafiltration tube and centrifuge at 6400 rpm (5000 g) for 45 min. Add 0.2 ml of the supernatant to a preweighed (accurate to 0.1 mg) 1.7-mL microcentrifuge tube, record the weight, add 0.8 ml of buffered enzyme mix, and record the weight. Cap, vortex, and incubate the solution at 50 C for 60 min. After 1 h, remove the tube and place in a boiling water bath to denature the enzymes. Then move the tube to an ice bath to precipitate the enzymes (approximately 5 min). Microfuge for 10 min, and then filter through a 0.2-µm syringe filter into an autosampler vial. This solution should be analyzed by HPAE-PAD within 72 h. Analyze each sample in triplicate. ELUENT PREPARATION 150 mm Sodium Hydroxide It is essential to use high-quality water of high resistivity (17.8 MΩ-cm or better) that contains as little dissolved carbon dioxide as possible. Biological contamination should be absent. Sodium hydroxide eluent should be prepared with 50% (w/w) sodium hydroxide. Sodium hydroxide pellets are covered with a thin layer of sodium carbonate and should not be used under any circumstances. To prepare 2 L of 150 mm NaOH, use a 10-mL graduated plastic pipet to deliver 15.6 ml 50% (w/w) sodium hydroxide into 1 L of water. Then add water to reach 2 L. Stir this solution only one to two minutes. Excessive mixing will increase the carbonate ion in the solution by trapping carbon dioxide from the air. After preparation, keep the eluent blanketed under helium at 34 55 kpa (5 8 psi) at all times. If maintained under helium, this eluent remains viable for approximately one week. 150 mm Sodium Hydroxide/0.5 M Sodium Acetate Measure approximately 800 ml of water into a 1-L graduated cylinder. Add a stir bar and begin stirring. Weigh out 41.0 g of anhydrous crystalline sodium acetate. Steadily add the sodium acetate while briskly stirring the water. After the salt dissolves, remove the stir bar with a magnetic retriever and use a 10-mL graduated plastic pipet to add 7.8 ml of 50% (w/w) sodium hydroxide to the sodium acetate solution. Add water to the solution to reach a final volume of 1 L, replace the stir bar, and stir briefly to mix. Vacuum filter this solution through a 0.2 µm nylon filter. The vacuuming may be slowed if the filter clogs with insoluble impurities from the sodium acetate. After preparation, keep the eluent blanketed under helium at 34 55 kpa (5 8 psi) at all times. If maintained under helium, this eluent is viable for approximately one week. CALCULATIONS Calculate the concentration of the stock standard by dividing the weight of the polydextrose (mg) by the weight of the water (g) added. Multiply this value by 1000 to convert the concentration to mg/g. Calculate the concentrations of the intermediate standards from the known dilutions of the stock standard (this calculation assumes that dilutions were not made to achieve the exact intermediate standard concentrations noted above). Calculate the concentration of each working standard by dividing the weight of the 0.2-mL aliquot of the intermediate standard by the sum of the weight of the 0.2-mL aliquot of the intermediate standard and the 0.8-mL aliquot of the buffered enzyme mix. Then multiply the quotient by the intermediate standard concentration. To calculate the percent polydextrose in a food sample, multiply the µg/g polydextrose concentration (determined from the calibration curve) by sum of the weight of the 0.2-mL sample aliquot and the 0.8-mL aliquot of the buffered enzyme mix, divided by the Application Note 147 3

Column: CarboPac PA1 and guard Eluent: 150 mm sodium acetate for 12 min 500 mm sodium acetate from 12.1 to 17 min 150 mm sodium acetate from 17.1 to 25 min Temperature: 30 C Flow Rate: 1.2 ml/min Inj. Volume: 25 µl Detection: PAD (Au), Waveform A (TN 21) Peaks: 1. Polydextrose 150 mg/l Column: CarboPac PA1 and guard Eluent: 150 mm sodium acetate for 12 min 500 mm sodium acetate from 12.1 to 17 min 150 mm sodium acetate from 17.1 to 25 min Temperature: 30 C Flow Rate: 1.2 ml/min Inj. Volume: 25 µl Detection: PAD (Au), Waveform A (TN 21) Peaks: 1. Polydextrose 196 mg/l 200 1 250 1 nc nc 0.01 0 5 10 15 20 25 Minutes 0 0 5 10 15 20 25 Minutes 18927 18928 Figure 1. HPAE-PAD separation of 150-mg/L polydextrose using Waveform A. weight of the 0.2-mL aliquot. Multiply this value by the sum of the weight of the food and water, divided by the weight of the food. Then multiply by 0.0001 (this factor converts µg polydextrose to g and converts the g polydextrose per g sample to a percent value). Figure 2. HPAE-PAD determination of polydextrose in milk chocolate candy using Waveform A. RESULTS AND DISCUSSION The procedure described in this application note, and in AOAC Method 2000.11, uses hot water to extract polydextrose from foods. Centrifugal ultrafiltration removes the high-molecular-weight components, and then treatment with a mixture of fructanase, amyloglucosidase, and isoamylase removes oligosaccharide interferences. The sample is then analyzed by HPAE-PAD. Figure 1 shows the HPAE-PAD separation of a 150-mg/L polydextose standard. This separation uses a rapid change in eluent concentration at 12 min (from 150 mm sodium acetate to 500 mm sodium acetate) to elute all the polydextrose polymers as one peak. To determine the concentration of polydextrose in samples, an eight-point polydextrose standard calibration curve ranging 50 500 mg/l was established. Triplicate injections of each standard level were made, and the peak areas were fit with a quadradric equation. The correlation coefficient was 0.999. Method 2000.11 states that a polynomial regression of the eight-point calibration should have a correlation 0.995. We participated in the collaborative study of what is now AOAC Method 2000.11. This method specified the use of a triple-potential waveform (Waveform B, Dionex Technical Note 21) for the PAD of polydextrose. We analyzed the seven blind duplicate samples (identities later revealed and are shown here in Table 2, column 1), and reported the percent polydextrose values in the second column of Table 2. 2 These values were consistent with the values determined by the other seven labs participating in the study. Figure 2 shows the HPAE-PAD determination of one of the milk chocolate candy samples. After the originators of this method finished its development, a new quadruple-potential PAD waveform was described that yields significantly improved, longterm peak area reproducibility for carbohydrate detection. 4 This waveform, Waveform A, was used in the 4 Determination of Polydextrose in Foods by AOAC Method 2000.11

Table 2. Comparison of Percent Polydextose in Food Samples Determined Using AOAC Method 2000.11 with Either Waveform A or Waveform B Sample Polydextrose (%) Determined with Waveform B Polydextrose (%) Determined with Waveform A Milk Chocolate Candy #1 19.49 20.64 Milk Chocolate Candy #2 20.08 20.20 Iced Tea #1 1.88 1.91 Iced Tea #2 1.94 1.93 Grape Jelly #1 5.58 5.05 Grape Jelly #2 5.42 5.29 Soft Jellied Candy #1 37.78 38.39 Soft Jellied Candy #2 32.25 32.44 Sugar Cookie #1 7.24 7.51 Sugar Cookie #2 8.05 8.20 Powdered Drink Mix #1 1.94 1.96 Powdered Drink Mix #2 1.95 1.94 Polydextrose Sample #1 90.70 91.04 Polydextrose Sample #2 96.50 97.96 chromatograms in Figures 1 and 2. Immediately after we analyzed the collaborative study samples with Waveform B, we analyzed them with Waveform A. The results using Waveform A are presented in the third column of Table 2. A comparison of Table 2, columns 2 and 3, reveals that Waveform A yields results equivalent to those determined with Waveform B. Because there is greater long-term peak area reproducibility with Waveform A, we recommend its use when following AOAC Method 2000.11. PRECAUTIONS AND RECOMMENDATIONS For best results, the Ag/AgCl reference electrode should be replaced every three to six months. REFERENCES 1. Craig, S. A. S.; Holden, J. F.; Khaled, M. Y. J. AOAC. Int. 2000, 83, 1006 1012. 2. Craig, S. A. S.; Holden, J. F.; Khaled, M. Y. J. AOAC. Int. 2001, 84, 472 478. 3. Dionex Corporation. Technical Note 21; Sunnyvale, CA. 4. Rocklin, R. D.; Clarke, A. P.; Weitzhandler, M. Anal. Chem. 1998, 70, 1496 1501. LIST OF SUPPLIERS Fisher Scientific, 711 Forbes Avenue, Pittsburgh, Pennsylvania, 15219-4785, USA, Tel: 1-800-766-7000, www.fishersci.com. Fluka Chemika-Biochemika, Fluka Chemie AG, Industriestrasse 25, CH-9471 Buchs, Switzerland, Tel: 81 755 25 11, www.sigma-aldrich.com. Megazyme International Ireland Ltd., Bray Business Park, Bray, County Wicklow, Ireland, Tel: 353 1 286 1220, www.megazyme.com. Millipore, 80 Ashby Road, Bedford, MA 01730, USA, Tel: (800) MILLIPORE, www.millipore.com. Application Note 147 5

Vortex-Genie is a registered trademark of Scientific Industries, Inc. CarboPac is a trademark, and BioLC and Chromeleon are registered trademarks of the Dionex Corporation. Dionex Corporation Dionex Corporation Dionex U.S. Regional Offices Dionex International Subsidiaries 1228 Titan Way Salt Lake City Technical Center Sunnyvale, CA (408) 737-8522 Austria (01) 616 51 25 Belgium (03) 353 42 94 Canada (905) 844-9650 China (852) 2428 3282 Denmark 36 36 90 90 P.O. Box 3603 1515 West 2200 South, Suite A Westmont, IL (630) 789-3660 France 01 39 30 01 10 Germany 06126-991-0 Italy (06) 66 51 50 52 Japan (06) 6885-1213 The Netherlands (0161) 43 43 03 Sunnyvale, CA Salt Lake City, UT Houston, TX (281) 847-5652 Switzerland (062) 205 99 66 United Kingdom (01276) 691722 94088-3603 6 Determination 84119-1484 of Polydextrose Atlanta, GA (770) in 432-8100 Foods * Designed, by AOAC developed, and Method manufactured under 2000.11 an NSAI registered ISO 9001 Quality System. (408) 737-0700 (801) 972-9292 Marlton, NJ (856) 596-06009 LPN 1528 PDF 4/03 2003 Dionex Corporation