Original Article Breast Imaging

Similar documents
Diagnostic benefits of ultrasound-guided. CNB) versus mammograph-guided biopsy for suspicious microcalcifications. without definite breast mass

Underestimation of Atypical Ductal Hyperplasia at Sonographically Guided Core Biopsy of the Breast

Ultrasonography-guided 14-gauge core biopsy of the breast: results of 7 years of experience

Sonographically Guided Core Biopsy of the Breast: Comparison of 14-Gauge Automated Gun and 11-Gauge Directional Vacuum-Assisted Biopsy Methods

Department of Radiology, Research Institute of Radiological Science, Yonsei University, College of Medicine, Seodaemun-gu, Seoul, Republic of Korea

Pseudoaneurysm of the Breast During Vacuum-Assisted Removal

Stereotactic 11-Gauge Vacuum- Assisted Breast Biopsy: A Validation Study

Atypical Ductal Hyperplasia and Papillomas: A Comparison of Ultrasound Guided Breast Biopsy and Stereotactic Guided Breast Biopsy

Atypical ductal hyperplasia diagnosed at ultrasound guided biopsy of breast mass

Sonographically-Guided 14-Gauge Core Needle Biopsy for Papillary Lesions of the Breast

Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision

Journal of Breast Cancer

Comparison of Sonographically Guided Core Needle Biopsy and Excision in Breast Papillomas

Stereotactic vacuum-assisted breast biopsy under lateral decubitus position

Does Ultrasound-Guided Directional Vacuum-Assisted Removal Help Eliminate Abnormal Nipple Discharge in Patients with Benign Intraductal Single Mass?

Imaging-cytology correlation of thyroid nodules with initially benign cytology

Journal of Breast Cancer

CNB vs Surgical Excision

Treatment options for the precancerous Atypical Breast lesions. Prof. YOUNG-JIN SUH The Catholic University of Korea

Excisional biopsy or long term follow-up results in breast high-risk lesions diagnosed at core needle biopsy

Poster No.: C-0466 Congress: ECR 2010 Scientific Exhibit

Ductal carcinoma in situ, underestimation, ultrasound-guided core needle biopsy

Diagnostic accuracy of ultrasonography-guided core needle biopsy for breast lesions

Mammographic features and correlation with biopsy findings using 11-gauge stereotactic vacuum-assisted breast biopsy (SVABB)

Table 1. Classification of US Features Based on BI-RADS for US in Benign and Malignant Breast Lesions US Features Benign n(%) Malignant n(%) Odds

Imaging-Guided Core Needle Biopsy of Papillary Lesions of the Breast

Introduction ORIGINAL ARTICLE. 170 Ultrasonography 33(3), July 2014 e-ultrasonography.org

Validation of the fifth edition BI-RADS ultrasound lexicon with comparison of fourth and fifth edition diagnostic performance using video clips

Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough?

Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up

Six-Month Short-Interval Imaging Follow-Up for Benign Concordant Core Needle Biopsy of the Breast: Outcomes in 1444 Cases With Long-Term Follow-Up

Over the recent decades, breast ultrasonography (US) has

Breast calcifications are important mammographic features in the

BI-RADS CATEGORIZATION AND BREAST BIOPSY categorization in the selection of appropriate breast biopsy technique is also discussed. Patients and method

Usefulness of ultrasound elastography in reducing the number of Breast Imaging Reporting and Data System category 3 lesions on ultrasonography

Sonographic Detection and Sonographically Guided Biopsy of Breast Microcalcifications

Percutaneous Biopsy of the Breast

Atypical papillary lesions after core needle biopsy and subsequent breast carcinoma

Guidance on the management of B3 lesions

3/27/2017. Disclosure of Relevant Financial Relationships. Papilloma???

Cystic Hypersecretory Carcinoma of the Breast:

Sonographic Differentiation of Thyroid Nodules With Eggshell Calcifications

Breast Sonographic Elastography Using an Advanced Breast Tissue- Specific Imaging Preset

Journal of Breast Cancer

Macrobiopsy under X-Ray Guidance

Breast Lesion Excision System-Intact (BLES): A Stereotactic Method of Biopsy of Suspicius Non-Palpable Mammographic Lesions.

Radiologic and pathologic correlation of non-mass like breast lesions on US and MRI: Benign, high risk, versus malignant

Radiologic and pathologic correlation of non-mass like breast lesions on US and MRI: Benign, high risk, versus malignant

Repeat Ultrasound-Guided Fine-Needle Aspiration for Thyroid Nodules 10 mm or Larger Can Be Performed 10.7 Months After Initial Nondiagnostic Results

Three-dimensional ultrasound-validated large-core needle biopsy: is it a reliable method for the histological assessment of breast lesions?

Original Report. Mucocele-Like Tumors of the Breast: Mammographic and Sonographic Appearances. Katrina Glazebrook 1 Carol Reynolds 2

Diagnosis of Pseudoangiomatous Stromal Hyperplasia of the Breast: Ultrasonography Findings and Different Biopsy Methods

Spiculated breast masses on MRI: Which category should we choose, 4 or 5?

RESEARCH ARTICLE. Woo Jung Choi, Joo Hee Cha*, Hak Hee Kim, Hee Jung Shin, Hyunji Kim, Eun Young Chae, Min Ji Hong. Abstract.

PURPOSE IMAGE-GUIDANCE MODALITIES IMAGE-GUIDED BREAST BIOPSY. US-Techniques. Ultrasound. US guided NLOBB. TH. Helbich

Intraductal Mass on Breast Ultrasound: Final Outcomes and Predictors of Malignancy

ISSN X (Print) Research Article. *Corresponding author Dr. Amlendu Nagar

Vacuum-assisted breast biopsy using computer-aided 3.0 T- MRI guidance: diagnostic performance in 173 lesions

Shear-wave elastography for breast masses: local shear wave speed (m/sec) versus Young modulus (kpa)

Quality ID #263: Preoperative Diagnosis of Breast Cancer National Quality Strategy Domain: Effective Clinical Care

Interobserver Variability of Ultrasound Elastography: How It Affects the Diagnosis of Breast Lesions

Multicenter Evaluation of the Breast Lesion Excision System, a Percutaneous, Vacuum-Assisted, Intact-Specimen Breast Biopsy Device

Prone table stereotactic breast biopsy

Pathologic outcomes of coarse heterogeneous calcifications detected on mammography

Management of B3 lesions

Radiologic Findings of Mucocele-like Tumors of the breast: Can we differentiate pure benign from associated with high risk lesions?

Complex cystic breast lesions, which are defined as lesions

Women s Imaging Original Research

Atypical Ductal Hyperplasia of the Breast:

Aims and objectives. Page 2 of 10

Proliferative Breast Disease: implications of core biopsy diagnosis. Proliferative Breast Disease

Controversies and Problematic Issues in Core Needle Biopsies (To excise or not to excise)

ORIGINAL ARTICLE. 128 Ultrasonography 33(2), April 2014 e-ultrasonography.org. Sung Hee Park 1, 2, Min Jung Kim 2, Soo Jin Kim 1, 2, Eun-Kyung Kim 2

Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

The Ratio of Atypical Ductal Hyperplasia Foci to Core Numbers in Needle Biopsy: A Practical Index Predicting Breast Cancer in Subsequent Excision

Pitfalls and Limitations of Breast MRI. Susan Orel Roth, MD Professor of Radiology University of Pennsylvania

Nonpalpable Breast Masses: Evaluation by US Elastography

The Breast Imaging Reporting and Data System (BI-RADS) was

Women s Imaging Original Research

Assessment of extent of disease: digital breast tomosynthesis (DBT) versus full-field digital mammography (FFDM)

Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

Effective Health Care Program

Breast Intraductal Papillomas Without Atypia in Radiologic- Pathologic Concordant Core-Needle Biopsies: Rate of Upgrade to Carcinoma at Excision

A-005 US DIAGNOSIS OF NONPALPABLE BREAST LESIONS

Atypical And Suspicious Categories In Fine Needle Aspiration Cytology Of The Breast

National Diagnostic Imaging Symposium 2013 SAM - Breast MRI 1

RSNA, /radiol Appendix E1. Methods

Retrospective Analysis on Malignant Calcification Previously Misdiagnosed as Benign on Screening Mammography 스크리닝유방촬영술에서양성으로진단되었던악성석회화에대한후향적분석

Observer Agreement Using the ACR Breast Imaging Reporting and Data System (BI-RADS)-Ultrasound, First Edition (2003)

The Safety and Efficiency of the Ultrasound-guided Large Needle Core Biopsy of Axilla Lymph Nodes

Index words: Breast US Breast neoplasm Breast cancer

Incidence and Management of Complex Fibroadenomas

Ultrasonographic evaluation of women with pathologic nipple discharge

Does elastography change the indication to biopsy? IBDC

Ana Sofia Preto 19/06/2013

Immersion Ultrasonography of Excised Nonpalpable Breast Lesion Specimens after Ultrasound-Guided Needle Localization

Stereotactic vacuum-assisted biopsy (SVAB) of Nonpalpable Breast Microcalcifications: Advantage of clip placement (Prospective study)

Note: This copy is for your personal, non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, cont

Transcription:

Original Article Breast Imaging http://dx.doi.org/10.3348/kjr.2014.15.6.697 pissn 1229-6929 eissn 2005-8330 Korean J Radiol 2014;15(6):697-703 Percutaneous Ultrasound-Guided Vacuum-Assisted Removal versus Surgery for Breast Lesions Showing Imaging-Histology Discordance after Ultrasound-Guided Core-Needle Biopsy Yu-Mee Sohn, MD, PhD 1, 2, Jung Hyun Yoon, MD 1, Eun-Kyung Kim, MD, PhD 1, Hee Jung Moon, MD, PhD 1, Min Jung Kim, MD, PhD 1 1 Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul 120-752, Korea; 2 Department of Radiology, Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Seoul 130-872, Korea Objective: To evaluate the upgrade rate and delayed false-negative results of percutaneous vacuum-assisted removal (VAR) and surgical excision in women with imaging-histologic discordance during ultrasound (US)-guided automated core needle biopsy (CNB) of the breast and to validate the role of VAR as a rebiopsy method for these discordant lesions. Materials and Methods: Percutaneous US-guided 14-gauge CNB was performed on 7470 patients between August 2005 and December 2010. Our study population included 161 lesions in 152 patients who underwent subsequent rebiopsy due to imaging-histologic discordance. Rebiopsy was performed using VAR (n = 88) or surgical excision (n = 73). We investigated the upgrade rate immediately after rebiopsy and delayed false-negative results during at least 24 months of follow-up after rebiopsy. We also evaluated the clinicoradiological differences between VAR and surgical excision. Results: Total upgrade to malignancy occurred in 13.7% (22/161) of lesions at rebiopsy including both VAR and surgical excision: 4.6% (4/88) of VAR cases (4/88) and 24.7% (18/73) of surgical excision cases (p < 0.001). Surgical excision was performed significantly more frequently in older patients and for larger-sized lesions than that of VAR, and a significant difference was detected between VAR and surgical excision in the Breast Imaging and Reporting and Data System category (p < 0.007). No delayed false-negative results were observed after VAR or surgical excision during the follow-up period. Conclusion: Long-term follow-up data showed no delayed cancer diagnoses after US-guided VAR in imaging-histologic discordant lesions of the breast, suggesting that VAR might be a rebiopsy method for these lesions. Index terms: Imaging-histologic discordance; Core needle biopsy; Vacuum-assisted removal; Surgical excision Received May 25, 2014; accepted after revision September 10, 2014. This study was supported by the Basic Science Research Program of the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning, Republic of Korea (grant 2013R1A1A3013165) and by a faculty research grant of Yonsei University College of Medicine for 2013 (6-2013-0094). Corresponding author: Min Jung Kim, MD, PhD, Department of Radiology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 120-752, Korea. Tel: (822) 2228-7400 Fax: (822) 393-3035 E-mail: mines@yuhs.ac This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. INTRODUCTION Ultrasound (US)-guided core needle biopsy (CNB) is an accurate and standard method for sampling lesions that are visible on US (1). However, CNB may underestimate results (2, 3) or produce false-negative results (4, 5), and various factors can affect CNB accuracy (6). Therefore, many solutions have been suggested, including confirmation of lesion retrieval by specimen radiography, correlating postbiopsy imaging and histology, larger sampling for imaginghistologic discordant lesions, and follow-up after benign biopsy results (7). The frequency of imaging-histologic discordance has been reported to be 1 6%, and several studies have reported 697

Sohn et al. imaging-histologic discordance following stereotactic CNB (4, 8, 9) and US-guided CNB (1, 6, 8, 10-12). These reports show malignancy rates of 6.8 29.3% in imaging-histologic discordant lesions during US-guided biopsy (1, 6, 10, 12-15), suggesting that rebiopsy of those lesions will yield benign pathology in approximately 70.7 93.2% of cases. Considering the large percentage of benign pathology at rebiopsy, Kim et al. (12) used vacuum-assisted removal (VAR) on discordant cases for a definitive diagnosis. However, the number of patients in that study was small (n = 26), and the follow-up period was limited. Some investigators have reported results of VAR management of imaginghistologic discordant lesions (13, 15). However, the number of patients in those studies was small (n = 28 and 55), and they used a 16-gauge core biopsy needle instead of a 14-gauge core biopsy needle (13, 15). Moreover, their follow-up period was 12 months, which is insufficient to confirm the absence of false-negative biopsy results after VAR. Therefore, the purpose of this study was to evaluate the upgrade rate and delayed false-negative results of percutaneous VAR in women with imaging-histologic discordance during US-guided automated CNB of the breast and to compare these results with those of surgical excision. MATERIALS AND METHODS This retrospective study was approved by our Institutional Review Board, and informed consent was waived. Patients and Biopsy Technique Percutaneous US-guided 14-gauge CNB was performed on 7470 female patients between August 2005 and December 2010. US-guided CNB was performed using a free-hand technique, guided by a 5 10 MHz or 5 12 MHz lineararray transducer (ATL HDI 5000 or iu-22 Philips Advanced Technology Laboratories, Bothell, WA, USA). A 14-gauge semi-automated CNB (Stericut, TSK Laboratory, Tochigi, Japan) was used. All biopsies were performed by one of six full-time board-certified radiologists dedicated to breast imaging. The radiologists had varying degrees of experience in breast imaging of 1 10 years. Typically, four or five core samples were obtained, and the number of core samples was determined at the discretion of each radiologist. Imaging-Histologic Correlation and Post-Biopsy Management All breast-dedicated radiologists reviewed the final pathological reports for all biopsied lesions on a weekly basis. These reports were reviewed in conjunction with mammographic and sonographic images within 1 week of biopsy. Radiologists determined whether the imaging findings and histological results were concordant or discordant. The imaging and histological findings were considered concordant when the histological findings provided an acceptable explanation for the imaging features and discordant when they did not (12). Discordant lesions included: 1) lesions that were suspicious for malignancy, e.g., Breast Imaging and Reporting and Data System (BI- RADS) category 4 (16), when the histological findings did not account for the imaging features (12); and 2) lesions that were highly suggestive of malignancy, e.g., BI-RADS category 5, revealing benign histological results, unless the specific histology accounted for the imaging features. Findings were considered concordant after a consensus was obtained among all the radiologists on each case. However, if at least one radiologist disagreed, the lesion was regarded as discordant. Vacuum-assisted removal (Mammotome; Ethicon Endo Surgery, Cincinnati, OH, USA) was recommended for discordant lesions (12). VAR was performed after administering local anesthesia. The gauge of the probe used was determined by the lesion size: an 8-gauge probe for lesions > 1.5 cm, an 11-gauge probe for lesions < 1.0 cm, and an 8-gauge or 11-gauge probe for lesions 1.0 1.5 cm in the largest dimension, according to the patient s breast thickness after a small skin incision. Multiple core samples were obtained under US guidance until the mass was completely removed. Skin tears or chest wall muscle injuries were regarded as serious complications (12). A US image was taken after biopsy to verify that the mass had been removed completely. Some lesions were surgically excised, and this decision was made at the discretion or request of the physician or patient. Thus, 265 lesions in 250 patients were assessed as imaging-histologic discordant results after the imaginghistologic correlation was performed. Among all lesions, we excluded 66 lesions that had undergone imaging followup without rebiopsy, such as VAR or surgical excision, at our institution. We also excluded 38 lesions in which the histological findings mandated a surgical excision regardless of the US findings, including papilloma (n = 13), atypical 698

Percutaneous Ultrasound-Guided Vacuum-Assisted Removal as a Rebiopsy Method ductal hyperplasia (n = 3), phyllodes tumor (n = 1), and discordant malignant lesions (n = 21). Therefore, our study population included 152 patients with 161 lesions (Fig. 1). Of the patients who underwent VAR and surgical excision, 97 (64%, 97/152) were followed for more than 24 months (median, 43 months; range, 24 88 months). Patients with less than 24 months of follow-up after VAR (n = 36) or surgical excision (n = 19) were contacted by phone to ask about breast cancer occurrence thereafter. Data Analysis The lesions were classified into the final US BI-RADS assessment categories prior to US-guided CNB (16). Surgical excision or follow-up US, imaging studies, and histological findings were reviewed, and follow-up data were obtained for breast lesions with imaging-histologic discordance at the initial percutaneous 14-gauge CNB and that underwent subsequent VAR. Age, BI-RADS category, and histological results were reviewed from medical records. We calculated the discordant lesion upgrade rates for VAR and surgical excision. Upgrade was defined when a patient had at least one lesion classified as a carcinoma at VAR or surgical excision. The upgrade rate was assigned to patients with ductal carcinoma in situ or invasive carcinoma. We also investigated delayed false-negative results during the follow-up period after VAR or surgical excision. Statistical analyses were performed using the chi-square test for categorical variables and the t test for continuous variables. The data were processed with the SPSS ver. 20.0 statistical software package (SPSS Inc., Chicago, IL, USA). RESULTS Differences in Clinical and Radiological Findings between VAR and Surgical Excision Among the 161 lesions in 152 patients who had discordant results after the imaging-histologic correlation, 73 lesions were removed by surgical excision and 88 lesions were removed by VAR. All 152 patients were female with a median age of 45 years (range, 19 77 years; mean, 45.4 years). Among the 88 breast lesions with VAR, 62 were biopsied with an 8-gauge probe, and 26 lesions were biopsied with an 11-gauge probe. The median number of acquired tissue samples was 17 (range, 6 176). No serious complications were observed after VAR. Older patients were referred to surgical excision (mean ± standard deviation [SD], 47.9 ± 10.1 years) more often than VAR (mean ± SD, 43.2 ± 10.9 years) (p = 0.007) (Table 1). Additionally, the lesions that were surgically excised were larger than the lesions that received VAR (16.9 ± 10.8 mm vs. 13.6 ± 6.3 mm) (p = 0.021). A significant difference was observed in the BI-RADS category for VAR and surgical excision (p = 0.026); surgical excision was performed more often for lesions in categories 4c and 5 compared to VAR. 66 lesions in 62 patients 38 lesions in 36 patients Imaging F/U without rebiopsy excluded Discordant malignant & high risk lesions excluded 265 lesions in 250 patients 199 lesions in 188 patients 161 lesions in 152 patients Fig. 1. Diagram of our study population. F/U = follow-up Histological Results after CNB and Subsequent VAR and Upgrade Rates Table 2 shows the initial histological results that included Table 1. Age, Lesion size, BI-RADS Categories According to Tissue Acquisition Method in Imaging-Histologic Discordant Lesions (n = 161) VAR (n = 88) Surgical Excision (n = 73) Patient age (mean ± SD) 43.2 ± 10.9 47.9 ± 10.1 Lesion size (mm) (mean ± SD) 13.6 ± 6.3 16.9 ± 10.8 BI-RADS category 4a 41 (46.6) 24 (32.9) 4b 32 (36.4) 24 (32.9) 4c 14 (15.9) 18 (24.6) 5 1 (1.1) 7 (9.6) Note. Numbers in parenthesis are percentages. BI-RADS = Breast Imaging and Reporting and Data System, SD = standard deviation, VAR = vacuum-assisted removal 699

Sohn et al. imaging-histologic discordant lesions (n = 161). Twentytwo lesions (VAR 4.6%, 4/88; surgical excision 24.7%, 18/73) were upgraded to malignant after rebiopsy (Figs. 2, 3). A significant difference in the upgrade rate was observed between VAR and surgical excision (p < 0.001). The histological profiles of initial CNB, VAR, and surgical excision in the upgraded lesions (n = 22) are listed in Table 3. Delayed False-Negative Results after VAR No delayed false-negative results (i.e., no delayed cancer diagnosis) were observed in the follow-up patients after VAR or surgical excision (VAR; 0%, 0/83; and surgical excision; 0%, 0/69). Table 2. Initial Histologic Results of Imaging-Histologic Discordant Lesions (n = 161) Initial CNB Results Frequency Fibrocystic change 53 Stromal fibrosis 40 Fibroadenoma 18 Adenosis 16 Fibroadenomatous hyperplasia 14 Ductal epithelial hyperplasia 11 Duct ectasia 5 Other* 4 Total 161 Note. *Fibrous tissue (n = 2), organizing thrombus (n = 1), columnar cell change (n = 1). CNB = core needle biopsy DISCUSSION Ultrasound-guided CNB is an easily accessible and accurate method to diagnose breast lesions. However, underestimated rates and false-negative results could be a drawback of US-CNB as a biopsy method (2-5). Therefore, the imaging-histologic correlation after US-CNB is widely used as a method to reduce the false-negative and underestimated results of CNB. Additionally, larger samples are required for imaging-histologic discordant lesions, so surgical excision has traditionally been used to biopsy such lesions (10). However, VAR was recently reported as an alternative to surgery because of its efficacy (12, 13, 15, 17, 18). Rajan et al. (18) reported adopting vacuumassisted biopsy (VAB) instead of diagnostic surgery for lesions of uncertain malignant potential, such as radial scars, papillomas, flat epithelial atypia, atypical ducal hyperplasia, and atypical lobular hyperplasia, to reduce the number of benign-diagnosed surgical biopsies, suggesting VAB as an alternative biopsy method to surgery. We focused only on the VAR indication in cases of imaging-histologic discordance after 14-gauge CNB but we did not include high risk lesions, as in Rajan et al. (18). Many studies (1, 6, 9, 10, 12, 13, 15, 19) have reported the role of VAR; however, they included all VAR cases, not just those that were imaging-histologic discordant. Son et al. (1) performed VAR in 53 lesions among 103 imaging-histologic discordant cases, but we included a larger study population with A B C Fig. 2. 51-year-old woman with mammographic abnormality. A. Left mediolateral oblique mammography view shows partially obscured hyperdense mass. B. Transverse sonogram corresponding to mammographic abnormality shows microlobulated hypoechoic mass (arrows) classified as Breast Imaging and Reporting and Data System category 4a. Ultrasound-guided core needle biopsy reveals fibrocystic change; however, this result was regarded as discordant benign. C. Eleven-gauge vacuum-assisted removal (arrowheads) was performed, and histological results indicated invasive ductal carcinoma. 700

Percutaneous Ultrasound-Guided Vacuum-Assisted Removal as a Rebiopsy Method A B C Fig. 3. 77-year-old woman with palpable mass in her left breast. A. Left mediolateral oblique mammography view shows irregular shaped hyperdense mass. B, C. Transverse (B) and longitudinal (C) sonogram corresponding to palpable site shows irregular and hypoechoic mass (arrows) classified as Breast Imaging and Reporting and Data System category 5. Ultrasound-guided core needle biopsy revealed intraductal papilloma; however, this result was regarded as discordant benign. Surgical excision was performed, and histological results revealed ductal carcinoma in situ. Table 3. Frequency of Carcinoma after VAR or Surgical Excision in Imaging-Histologic Discordant Lesions (n = 22) CNB Results VAR (n = 4) Surgical Excision (n = 18) Fibroadenoma 0 DCIS (1) Fibrocystic change IDC (1) DCIS (6) Cribriform carcinoma (1) IDC (2) Adenosis 0 DCIS (1) Stromal fibrosis DCIS (1) DCIS (1) Ductal epithelial hyperplasia IDC (2) IDC (3) Duct ectasia 0 IDC (1) Other* 0 IDC (1), ILC (1) Note. *Fibrous tissue, organizing thrombus. CNB = core needle biopsy, DCIS = ductal carcinoma in situ, IDC = invasive ductal carcinoma, ILC = invasive lobular carcinoma, VAR = vacuumassisted removal discordant results (1). We evaluated the difference in upgrade rates between VAR and surgical excision and the role of VAR as a rebiopsy method for imaging-histologic discordant lesions after US-guided CNB with long-term follow-up results. The upgrade rate in the imaging-histologic discordant lesions after VAR or surgical excision has been reported to be 6.8 29.3% (Table 4) (1, 6, 10, 12-15). The upgrade rates in our study were 4.6% and 24.6% for VAR and surgical excision, respectively, which is similar to the range reported previously. Surgical excision was performed significantly more frequently on older patients, with larger lesions, and on category 4c and 5 lesions compared to those of VAR. These results suggest that the rebiopsy method was determined by the surgeon s discretion with patient preference limited in scope. The most significant reason for the differences between VAR and surgical excision was that surgeons directly performed therapeutic surgery after confirming the frozen excisional biopsy result for more suspicious lesions rather than VAR. Our upgrade rate was 13.6% in all lesions; however, if all lesions were surgically excised, unnecessary surgery could reach up to 86.4%. Therefore, VAR could be an alternative method for reducing needless surgery and planning a well-designed operation. Kim et al. (12) also reported that surgical excision was performed more frequently on BI-RADS category 4c lesions compared to VAR, compatible with our result. However, that study reported no difference between VAR and surgical excision, unlike our study (12). Liberman et al. (10) reported that 10.5% (2/19) of their results were immediate false negatives under USguidance during a 7-year period. Their upgrade rate to malignancy (10.5%) was higher than our upgrade rate (4.6%), though these two results are almost within the previously reported range (6.8 29.3%) (1, 6, 10, 12-15). Imaging-histologic discordance tends to be determined by the radiologist s experience rather than by well-established criteria. However, the upgrade rates of these discordant lesions were still greater than the reported 2% probability of malignancy in BI-RADS category 3, which are primarily benign lesions. Thus, larger tissue samples are required for 701

Sohn et al. Table 4. Published Reports Applying of Vacuum-Assisted Biopsy or Removal to Imaging-Histologic Discordant Lesions Investigator Rebiopsy Method Population* Upgrade to Malignancy (%) Follow-Up Period Kim et al. (12) US-VAR (8-G, 11-G) 18 11.1 NS Li et al. (13) US-VAB (10-G) 28 21.4 1 year Wang et al. (15) US-VAB or VAR (7-G) 55 22.7 (VAR) 21.2 (VAB) 1 year Our study US-VAR (8-G, 11-G) 88 4.6 At least 2 year Note. *Lesion number. G = gauge, NS = not stated, US = ultrasound, VAB = vacuum-assisted biopsy, VAR = vacuum-assisted removal imaging-histologic discordant lesions. Appropriate follow-up should be performed after benign biopsy results to prevent immediate and delayed false-negative results. No delayed cancer diagnoses were made in either the follow-up patients or patients contacted by phone in the present study. A few studies have reported delayed falsenegative results (20-23), Peter et al. (21) reported a 1.4% rate of delayed false-negative results; however, their results were obtained by stereotactically guided vacuum biopsy, instead of US-guided VAR; thus, they could not warrant complete removal of the lesions. Unlike US-guidance, it is difficult to completely remove lesions with stereotactic VAB because lesion boundaries cannot be assessed during the procedure, which may explain their delayed false-negative results. Perez-Fuentes et al. (20) reported no delayed falsenegative results after US-guided 11-gauge VAB. Although their complete removal rate was limited to 88.6% (78/88 lesions) and 24-month follow-up data were available for 71 lesions, their study was not confined to imaging-histologic discordant lesions. Two other studies (22, 23) reported no delayed false-negative results after VAR for benign lesions. However, their indication was benign lesions; thus, delayed false-negative results were not within the scope of those studies. Therefore, the current study is the first to report a lack of VAR delayed false-negative results in imaginghistologic discordant lesions with a large number of patients and a long-term follow-up. Our study had several limitations. First, the VAR and surgery groups were not randomized due to the retrospective nature of the study and were dissimilar in major patient characteristics, as the rebiopsy method was determined according to the surgeon s discretion. The most significant reason for the differences between VAR and surgical excision was that the surgeon directly performed the therapeutic surgery after confirming the frozen excisional biopsy result for more suspicious lesions rather than VAR. Although our results suggest applying VAR more broadly, a prospective randomized study will be necessary to solve this limitation. Second, some patients who did not have sufficient imaging follow-up data, including those with less than a 24 month follow-up, were contacted by phone regarding the occurrence of breast cancer after VAR (n = 36) or surgical excision (n = 19). These patient s responses were not verified by imaging follow-up; however, the phone interviews were performed more than 2 years after VAR or surgical excision. Therefore, no cancer occurrence after more than 2 years was evident. In conclusion, long-term follow-up data showed no delayed cancer diagnoses after US-guided VAR in imaginghistologic discordant lesions of the breast; thus, VAR might be considered a rebiopsy method for imaging-histologic discordant lesions. REFERENCES 1. Son EJ, Kim EK, Youk JH, Kim MJ, Kwak JY, Choi SH. Imaging-histologic discordance after sonographically guided percutaneous breast biopsy: a prospective observational study. Ultrasound Med Biol 2011;37:1771-1778 2. Jang M, Cho N, Moon WK, Park JS, Seong MH, Park IA. Underestimation of atypical ductal hyperplasia at sonographically guided core biopsy of the breast. AJR Am J Roentgenol 2008;191:1347-1351 3. Suh YJ, Kim MJ, Kim EK, Moon HJ, Kwak JY, Koo HR, et al. Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuumassisted biopsy. Br J Radiol 2012;85:e349-e356 4. Shah VI, Raju U, Chitale D, Deshpande V, Gregory N, Strand V. False-negative core needle biopsies of the breast: an analysis of clinical, radiologic, and pathologic findings in 27 concecutive cases of missed breast cancer. Cancer 2003;97:1824-1831 5. Youk JH, Kim EK, Kim MJ, Kwak JY, Son EJ. Analysis of falsenegative results after US-guided 14-gauge core needle breast biopsy. Eur Radiol 2010;20:782-789 6. Kim MJ, Kim EK, Park SY, Jung HK, Park BW, Kim H, et al. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions. Eur J Radiol 2008;65:163-169 7. Youk JH, Kim EK, Kim MJ, Lee JY, Oh KK. Missed breast cancers at US-guided core needle biopsy: how to reduce them. 702

Percutaneous Ultrasound-Guided Vacuum-Assisted Removal as a Rebiopsy Method Radiographics 2007;27:79-94 8. Meyer JE, Smith DN, Lester SC, DiPiro PJ, Denison CM, Harvey SC, et al. Large-needle core biopsy: nonmalignant breast abnormalities evaluated with surgical excision or repeat core biopsy. Radiology 1998;206:717-720 9. Philpotts LE, Shaheen NA, Carter D, Lange RC, Lee CH. Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun. AJR Am J Roentgenol 1999;172:683-687 10. Liberman L, Drotman M, Morris EA, LaTrenta LR, Abramson AF, Zakowski MF, et al. Imaging-histologic discordance at percutaneous breast biopsy. Cancer 2000;89:2538-2546 11. Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF. US-guided core breast biopsy: use and cost-effectiveness. Radiology 1998;208:717-723 12. Kim MJ, Kim EK, Lee JY, Youk JH, Park BW, Kim SI, et al. Breast lesions with imaging-histologic discordance during US-guided 14G automated core biopsy: can the directional vacuum-assisted removal replace the surgical excision? Initial findings. Eur Radiol 2007;17:2376-2383 13. Li JL, Wang ZL, Su L, Liu XJ, Tang J. Breast lesions with ultrasound imaging-histologic discordance at 16-gauge core needle biopsy: can re-biopsy with 10-gauge vacuum-assisted system get definitive diagnosis? Breast 2010;19:446-449 14. Mihalik JE, Krupka L, Davenport R, Tucker L, Toevs C, Smith RS. The rate of imaging-histologic discordance of benign breast disease: a multidisciplinary approach to the management of discordance at a large university-based hospital. Am J Surg 2010;199:319-323; discussion 323 15. Wang ZL, Liu G, Li JL, Su L, Liu XJ, Wang W, et al. Breast lesions with imaging-histologic discordance during 16-gauge core needle biopsy system: would vacuum-assisted removal get significantly more definitive histologic diagnosis than vacuum-assisted biopsy? Breast J 2011;17:456-461 16. American college of radiology. Breast imaging reporting and data system (BI-RADS) ultrasound, 4th ed. Reston, VA: American College of Radiology, 2003 17. Cassano E, Urban LA, Pizzamiglio M, Abbate F, Maisonneuve P, Renne G, et al. Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 2007;102:103-110 18. Rajan S, Shaaban AM, Dall BJ, Sharma N. New patient pathway using vacuum-assisted biopsy reduces diagnostic surgery for B3 lesions. Clin Radiol 2012;67:244-249 19. Dershaw DD, Morris EA, Liberman L, Abramson AF. Nondiagnostic stereotaxic core breast biopsy: results of rebiopsy. Radiology 1996;198:323-325 20. Perez-Fuentes JA, Longobardi IR, Acosta VF, Marin CE, Liberman L. Sonographically guided directional vacuumassisted breast biopsy: preliminary experience in Venezuela. AJR Am J Roentgenol 2001;177:1459-1463 21. Peter D, Grünhagen J, Wenke R, Schäfer FK, Schreer I. Falsenegative results after stereotactically guided vacuum biopsy. Eur Radiol 2008;18:177-182 22. Kim MJ, Park BW, Kim SI, Youk JH, Kwak JY, Moon HJ, et al. Long-term follow-up results for ultrasound-guided vacuumassisted removal of benign palpable breast mass. Am J Surg 2010;199:1-7 23. Li S, Wu J, Chen K, Jia W, Jin L, Xiao Q, et al. Clinical outcomes of 1,578 Chinese patients with breast benign diseases after ultrasound-guided vacuum-assisted excision: recurrence and the risk factors. Am J Surg 2013;205:39-44 703