Learning objectives. What kind of motions? 3D Dosimetry in the Clinic: Motion Interplay Effects in Dynamic Radiotherapy

Similar documents
Future upcoming technologies and what audit needs to address

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry

Application(s) of Alanine

Limits of Precision and Accuracy of Radiation Delivery Systems

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

IMRT QA: Point Dose Measurements or 2D Array?

slide courtesy of Daniel Low Motion management Sofie Ceberg PhD, Medical Physicist Skåne University Hospital, Lund

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Dosimetric Analysis Report

Three Dimensional Dosimetry. Session Program: Therapy Education Session Organizer: L. John Schreiner

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Agenda. 1.1 Why pre-treament dosimetry in IMRT/VMAT? 1.2 Verification systems in IMRT/VMAT: from 0D to 3D (4D) dosimetry to real time dosimetry

ph fax

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Unrivaled, End-to-End

Leila E. A. Nichol Royal Surrey County Hospital

Small field diode dosimetry

Quality Assurance of Helical Tomotherapy Machines

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times

Dosisverifikation mit Delta 4 Discover während der Behandlung

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

Many vendors are beginning to allow couch motion during radiation delivery.

EORTC Member Facility Questionnaire

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Prostate Phantom. Guidelines for Planning and Treating the IMRT Prostate Phantom. Revised March 2014

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

Dosimetric characteristics of intensity-modulated radiation therapy and RapidArc therapy using a 3D N-isopropylacrylamide gel dosimeter

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Verification of Advanced Radiotherapy Techniques

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

IMRT pre-treatment verification basic approaches

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Pre-treatment and in-vivo dosimetry of Helical Tomotherapy treatment plans using the Dosimetry Check system

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Electron Beam ET - Reloaded Therapy - Reloaded

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised April 2014

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

Optimization of the T2 parametric image map calculation in MRI polymer gel dosimetry

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

3-D dose verification by cone-beam optical CT scanning of PRESAGE dosimeter

The MapCHECK Measurement Uncertainty function and its effect on planar dose pass rates

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

iviewdose Confidence and assurance in dose delivery

Computed tomography Acceptance testing and dose measurements

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Overview. Proton Therapy in lung cancer 8/3/2016 IMPLEMENTATION OF PBS PROTON THERAPY TREATMENT FOR FREE BREATHING LUNG CANCER PATIENTS

A review of RTTQA audit. Karen Venables

3D DOSIMETRY IN END-TO-END DOSIMETRY QA

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

BELdART-2: Moving towards safer radiotherapy. Steven Lelie 1,2, Wouter Schroeyers 1, Brigitte Reniers 1, Sonja Schreurs 1

Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation. Research and development to advance radiotherapy

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Reviewing three dimensional dosimetry: basics and utilization as presented over 17 Years of DosGel and IC3Ddose

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Patient-Specific QA & QA Process. Sasa Mutic, Ph.D. Washington University School of Medicine

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments

Evaluating Pre-Treatment IMRT & VMAT QA Techniques Using Receiver Operating. Characteristic (ROC) Analysis. Allison Lorraine Mitchell

The Radixact System Experience at Miami Cancer Institute. Tino Romaguera, D.Sc. Senior Physicist

A national dosimetric audit of VMAT and Tomotherapy in the UK

SunCHECK Patient Comprehensive Patient QA

Much of what we will say

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

Effective and efficient radiotherapy dosimetry audit: Where to next?

IMAT: intensity-modulated arc therapy

Online Care, Online Control, Online Confidence

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Dosimetric verification and quality assurance of runningstart-stop (RSS) delivery in tomotherapy

TomoTherapy Patient Quality Control With Dosimetry Check Version 5 Release 8. Math Resolutions, LLC 5975 Gales Lane Columbia, MD USA 21045

Delivery Quality Assurance with a High Resolution Liquid Filled Ion Chamber Array for Robotic Radiosurgery

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Radiotherapy Standards Users Meeting, 1 Dec 2008 Abstracts. New calorimeters Simon Duane, NPL

Activity report from JCOG physics group

Level of Accuracy Practically Achievable in Radiation Therapy. David Followill and RPC staff August 6, 2013

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

How Should We Verify Complex Radiation Therapy Treatments?

Active Scanning Beam 3 Checking Delivery/Dosimetry

Image Guided Stereotactic Radiotherapy of the Lung

Transcription:

3D Dosimetry in the Clinic: Motion Interplay Effects in Dynamic Radiotherapy Sofie Ceberg, PhD Medical Physicist and Lund University Lund, Sweden Learning objectives 1: 3D Dosimetry in the Clinic: Background and Motivation 2: 3D Dosimetry in the Clinic: Motion interplay effects in dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT 3: 3D Dosimetry in the Clinic and Research: Special techniques 4: 3D Dosimetry in end-to-end dosimetry QA What kind of motions? 1

If target moves during radiotherapy Dose distribution from a static delivery to a stationary target Dose distribution from a static delivery to a moving target Ceberg S., et al 2008 Verification of dynamic radiotherapy: the potential for 3D dosimetry under respiratory-like motion using polymer gel. PMB, 53 (20), pp. N387-396. If both target and MLC move??? Risk of serious under- and over-dosage! Interplay effects depends on... Patient specific: Breathing amplitude Period time Initial breathing phase Machine specific: Dose rate Plan modulation complexity Gantry rotation period/pitch/beam width 2

Measure interplay effects (only) How much of the target dose reduction is due to breathing interplay effects? Need to separate the obvious dose-smearing effect from the total measurement It is hard using conventional diod- or ion chamber arrays due to low spatial resolution It is possible using 3D gel dosimetry thousands of measuring points in a few cm 3 volume Ceberg S. et al 2013 Evaluation of breathing interplay effects Skåne during University VMAT by using Hospital 3D gel measurements. Journal of Physics: Conference Series Breathing gel-phantoms npag polymer gel 89% w/w water 5% w/w gelatine 3% w/w acrylamide 3% w/w bisacrylamide 10 mm THP Read out system MRI Overlay of 3D target isodose surfaces Lung VMAT measurements An obvious target dose reduction due to motion Ceberg S. et al 2013 Evaluation of breathing interplay effects Skåne during University VMAT by using Hospital 3D gel measurements. Journal of Physics: Conference Series, 444 (1), art. no. 012098 3

Total dosimetric effect of the motion Contains both the dose-smearing and potental interplay effects Distribution of the dose deviations between the gel volumes (-3.70±2.56)% (-4.31 ± 4.80)% (-3.60 ± 3.0) % The dosimetric effect of the interplay effects only Distribution of the dose deviations between the gel volumes (-1.20±1.40)% (0.94 ± 2.32)% (-0.90 ± 2.20) % In these clinically relevant example The total dosimetric effect due to breathing motion and dynamic MLC motion during VMAT and Tomo delivery resulted in an average of about 4% target dose reduction. For repeated stationary measurement, i.e. without interplay effects but including all other measurements uncertainties (e.g. set-up), the differences had a narrow distribution with a standard deviation between 0.5-0.9% (1SD). Thus, the larger standard deviations of 1.4%-2.3% (1SD) were interpreted as interplay effects. 4

Motion induced thread effect Experimentally verification of the motion induced thread effect during tomotherapy using 3D gel dosimetry. Edvardsson A. et al. 2015 Verification of motion induced Skåne thread effect University during tomotherapy Hospital using gel dosimetry Journal of Physics: Conference Series, 573 (1), art. no. 012048,. Motion induced thread effect > 6 % dose difference < -6 % dose difference Take home message To evaluate any potential breathing induced interplay effects during dynamic radiotherapy in your clinic use a 3D detector system with high resolution that accumulates the absorbed dose 5