#AH145 - TSD101B Respiratory Effort Transducer

Similar documents
SS11LA Pneumotach Transducer

Raw BP and Eight Hemodynamic Measurements Displayed in Real Time

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

Lesson 9. Measuring Emotional Responses to the Acoustic Startle Reflex: Stimulus Habituation & Sensitization

Biopac Student Lab Lesson 8 RESPIRATORY CYCLE I Analysis Procedure. Rev

Angular Measurements with BIOPAC Goniometers & Torsiometers

Lesson 2 EMG 2 Electromyography: Mechanical Work

Figure 1 The respiratory cycle

Comparing the Functional Performance of BIOPAC Respiratory Belt-Transducers With and Without Repair Tape

BP-600 Noninvasive Blood Pressure Sensor

Lesson 2 ELECTROMYOGRAPHY II Motor unit recruitment Fatigue

Biopac Student Lab Lesson 3 ELECTROENCEPHALOGRAPHY (EEG) I Analysis Procedure. Rev

Overview. Page 1 of 9. Impedance Cardiography

Emotional State Recognition via Physiological Measurement and Processing

Exercise 6: Muscle Physiology II Twitch & Summation

Lesson 4 ECG 2 Electrocardiography

BSL PRO Lesson H03: Nerve Conduction Velocity: Along the Ulnar Nerve of a Human Subject

FT-302 Force Transducer

#7 - Respiratory System

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure. Rev

Physiology Lessons for use with the Biopac Student Lab. Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG

Biopac Student Lab Lesson 5 ELECTROCARDIOGRAPHY (ECG) I Procedure. Rev

Labs #7 and #8: Vertebrate Skeletal Muscle

Breathing and pulmonary function

Lesson 5 EEG 1 Electroencephalography: Brain Rhythms

How to install the Wahoo RPM Cadence on your bike: How to install the Wahoo RPM Cadence using the Shoe Clip Mount:

Lesson 10 Aerobic Exercise Physiology

1724 Lab: Frog Skeletal Muscle Physiology (Marieb Exercise 16A) Marieb/iWorx / Ziser, 2002

Exercise 5: Muscle Physiology I - Electromyography

Dissection and Contraction of Frog Heart

iworx Sample Lab Experiment HP-7: Hypothesis-driven Biofeedback Lab/Research Study

iworx Sample Lab Experiment AN-10: Crustacean Stretch Receptor

Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

Biology 13A Lab #10: Cardiovascular System II ECG & Heart Disease

Richard Pflanzer, Ph.D. J.C. Uyehara, Ph.D. William McMullen David Pittman, Ph.D. Manual Revision PL3.7.0 M3.0.6 Modified by David Pittman

Electromyography II Laboratory (Hand Dynamometer Transducer)

Biology 236 Spring 2002 Campos/Wurdak/Fahey Laboratory 4. Cardiovascular and Respiratory Adjustments to Stationary Bicycle Exercise.

THE INFLUENCE OF IONS ON THE CONTRACTION OF ISOLATED EARTHWORM SMOOTH MUSCLE

Physiology Lessons for use with the Biopac Student Lab

The estimation of pulmonary functions in various body postures in normal subjects

Biopac Student Lab Lesson 20 SPINAL CORD REFLEXES Analysis Procedure. Rev

The Do s and Don ts of Pressure Transducers

Calibrating Respiratory Strain Gauges: What the Numbers Mean for Monitoring Respiration

Exercise 2: Effects of Cold Temperature Aim: To record changes in heart rate after the heart is bathed in cold Ringer s solution.

The Gaze Cueing Paradigm with Eye Tracking Background Set-up Lab

Heart Rate, Blood Pressure, and Exercise. Evaluation copy

841T. Adventure4 Adventure5 TREADMILL OWNER S MANUAL

R25 Recumbent Bike ASSEMBLY & PARTS MANUAL

FITNESS #1 HOME

Spirometry and Flow Volume Measurements

Warning: Avoid putting the tip of the syringe needle too deeply into the hole to avoid damage to the heart tissue.

Neurobiology: The nerve cell. Principle and task To use a nerve function model to study the following aspects of a nerve cell:

Posner s Attention Test

Overview Active Learning

Analysis of Lung Function

BH Fitness T4 / T6 SPORT Treadmill Owner s Manual

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement

Overview of the Scientific Process

Aerobic Lateral Trainer

USER MANUAL CT

POLYGRAPH BIOFEEDBACK

Experiment HP-13: The Gaze Cue Paradigm

Lab 4: Introduction to Physiological Measurements - Cardiovascular

Adventure 5 Plus Service Manual

Testing Masimo rainbow Technology with vpad-a1 1. Background

Heart Rate and Blood Pressure as Vital Signs

DSI Series Installation

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

PHM-100 PORTABLE HANDHELD TRANSDUCER INDICATOR OPERATORS MANUAL. Transducer Techniques R

HealthCare International, Inc. PO Box 1509, Langley, WA P: (360) or (800)

Table of Contents. Product Safety Part Drawing & Contents Hardware & Tools Assembly Adjustment

Parts identification:

Biomedical Instrumentation E. Blood Pressure

Casall R300 II Manual ROWER MACHINE

Exercise 1: Eye-Hand Reaction Times Aim: To measure the reaction time of a subject to a visual cue when responding with the hand.

Experiment HM-11: Electromyograms (EMG) for Paired Arm Wrestling

Lesson 5 BIOPAC Systems, Inc. Manual Revision PL3.7.5

PowerLab LabTutor Systems

INSTRUCTION MANUAL LEG PRESS (NEW MODEL) OPTION OF K2 GYM

USER S MANUAL. TENDO Weightlifting Analyzer Version V-207.

FITNESS BIKE. Vision Fitness E3100

Casall INFINITY 1.2X CROSSTRAINER 93008

iworx Sample Lab Experiment HC-3: Pulse Wave Velocity

SU UPRIGHT OWNER S MANUAL PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR UPRIGHT!

BH Fitness T8 SPORT Treadmill Owner s Manual

iworx Sample Lab Experiment AN-5: Cockroach Leg Mechanoreceptors

Enzyme Action: Testing Catalase Activity

Teacher s Guide. Physiology Lessons for use with the Biopac Science Lab MP40

Quick Notes. BioCapture : Acquiring Respiratory Effort data

USER S MANUAL. Proform logo QUESTIONS? ! WARNING. ote : the red of ProForm is antone 186 EC. Model No. PFICVRW Serial No.

SAFETY LABELS CAUTION: PINCH POINT. Make sure locking pin is fully engaged before beginning forward and side lift exercises.

Owner s Manual HealthCare International, Inc. PO Box 1509, Langley, WA

Figure 1: The EVH board

Polymer Bonded Explosives XTX 8004 (80 wt% PETN-20 wt% PDMS)

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

N4i Installation Manual. (picture of N4i screen)

PHYSIOLOGICAL PROPERTIES OF VISCERAL SMOOTH MUSCLE

Transcription:

BIOPAC Systems, Inc. 42 Aero Camino Goleta, CA 93117 Ph (805) 685-0066 Fax (805) 685-0067 www.biopac.com info@biopac.com #AH145 - TSD101B Respiratory Effort Transducer The TSD101B can be used to record respiratory effort, by measuring the change in thoracic or abdominal circumference. The TSD101B is a silicone rubber strain assembly that connects to a fully adjustable nylon strap to allow the transducer to fit any circumference. The transducer presents minimal resistance to movement and is extremely unobtrusive, making it well-suited for a variety of different applications. Due to its novel construction, the TSD101B can measure extremely slow respiration patterns with no loss in signal amplitude while maintaining excellent linearity and minimal hysteresis. To attach the nylon belt to the respiration transducer, thread the nylon strap through the corresponding slots on the bow tie so the strap clamps into place when tightened. The TSD101B is placed around the area of maximal expansion when the subject breathes, generally about 5 cm below the armpits and should be fitted so that it is snug. To fit the transducer, have the subject expire as deeply as possible, then tighten the nylon strap so that the bow tie is stretched approximately 1 cm. Important Use Note! Do not pull or yank the circular sensor element from the center of the silicone "Bowtie" strap. The file:////ntserver4/doc%20pdf/appnotes/app145tsd101b/resp2.htm (1 of 5)3/24/2006 10:03:19 AM

circular sensor is designed to reside at the bowtie center position. If the sensor is yanked to one side the transducer will be damaged. Use with MP100 System The transducer has three 2 mm pin plugs to connect to the amplifier. Two of the three connector wires are colored, these are plugged into either of the two input channels, labeled XDCR. The third pin wire is black and plugs into the channel labeled GND. The TSD101B plugs directly into the RSP100B amplifier module to measure a subject's respiration rate. RSP100B Amplifier Module Settings The RSP100B has three built-in filters and a number of different gain settings for the different uses of the transducer. The most common setting is with all three filters at their bottom settings (10Hz, DC, and DC) and the gain set at 10. This allows any and all signals slower than 10 Hz cyclic rate to pass, this is usually good for most measurements with little or no subject movement. For exercise physiology, the transducer conducts the best signal at the lowest gain and with all three filter settings at their top position (1Hz,.5Hz, and.05hz). This setting will allow only a signal between.5 Hz and 1Hz to be transmitted, filtering out most of the signal interference due to movement of the limbs. For studies on smaller animals with very small changes in thoracic circumference, you will probably need to increase the gain to magnify the signal level. Increase the gain until you get a clear signal, but not so much that the signal is clipped at subject's full inspiration. Type of Use Gain Setting Low Pass Filter.5 Hz Filter.05 Hz Filter General 10 10 Hz DC DC Exercise Phys. 10 1 Hz.5 Hz.05 Hz file:////ntserver4/doc%20pdf/appnotes/app145tsd101b/resp2.htm (2 of 5)3/24/2006 10:03:19 AM

Small Animal 20 or above 10 Hz.5 Hz DC Calibration of the TSD101B Calibration is generally not necessary for the respiration transducer when using it to calculate respiration rate. But if your application requires a direct linear measurement for the change in circumference, you can scale the instrument when you set up the recording channel. You will need to choose a gain setting before you calibrate the transducer. To calibrate the transducer, select Setup channels under the MP100 menu. Select the analog channel you are recording with, enable the Acquire and Plot functions and label it as respiration data, then select the Setup (Macintosh) or Scaling button (Windows). In the Channel scaling box, first, enter a zero value in the Cal 1 Map value box. Then using a ruler stretch the bow tie 1 cm, and click on the Cal 1 button. For the Cal 2 value, enter a 5 in the Cal 2 Map value box, stretch the bow tie 5 cm, then click on the Cal 2 button. When you attach the transducer, start acquiring data by clicking the Start button in the bottom right corner and tighten the belt until the signal reads at zero. Use with Biopac Student Lab PRO To set up the SS5LA for the PRO software, first select Setup channels from the MP30 menu. Select the analog channel you are recording with, enable the Acquire and Plot functions and label it as respiration data, then select the Setup (Macintosh) or Scaling button (Windows). From the Presets menu, select RSP for the SS5LA transducer. file:////ntserver4/doc%20pdf/appnotes/app145tsd101b/resp2.htm (3 of 5)3/24/2006 10:03:19 AM

You may change the filter settings, in the same Setup window by clicking on or off the appropriate filter. You may use the same guidelines for filtering as above. The gain setting is set for a human recording, if your subject is much smaller you can adjust the settings by clicking on the Gain box. The SS5LA can also be calibrated similarly to the TSD101B by selecting Scaling from the Input channel setup window. Follow the same protocol as that for the TSD101B calibration. file:////ntserver4/doc%20pdf/appnotes/app145tsd101b/resp2.htm (4 of 5)3/24/2006 10:03:19 AM

Sample Data for Subject at Rest. Return To Application Note Menu file:////ntserver4/doc%20pdf/appnotes/app145tsd101b/resp2.htm (5 of 5)3/24/2006 10:03:19 AM