Analytical Workflow for Extractable and Leachable Impurities

Similar documents
NON TARGETED SEARCHING FOR FOOD

Michal Godula Thermo Fisher Scientific. The world leader in serving science

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

Extractables and Leachables from Single Use Bioprocess Systems

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.

for new contaminants at ultra trace level by using high resolution mass spectrometry

Join the mass movement towards mass spectrometry

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Go beyond. to realities unexplored. Comprehensive workflows, integrated solutions

Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University

Agilent 7700x ICP-MS

Experiences with application of full scan high resolution MS for pesticide residue analysis

Metabolomics Strategies

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry

Matrix Interferences in ICP-MS: Causes, Effects, and Strategies to Reduce or Eliminate Them

US EPA SW-846 Method 6010D using the Thermo Scientific icap 7400 ICP-OES Duo

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

Amadeo R. Fernández-Alba

Elemental Scientific. seafast S2. Elution Profiles. Elemental Scientific

Sample Concentration and Analysis of Human Hormones in Drinking Water

1 Seminario di Spettrometria di Massa. Università degli studi di Milano 23/06/2017 The world leader in serving science

Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

THE POWER OF MASS SPECTROMETRY FOR IC ANALYTICAL CHEMISTS. Unleash New Possibilities with Enhanced Detection for IC Applications

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Introduction to the Oligo HTCS Systems. Novatia, LLC

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Polymer Additive Analysis by EI and APCI

New Instruments and Services

Designer Fentanyls Drugs that kill and how to detect them. Cyclopropylfentanyl

Chemical Analysis Business Operations Waters Corporation Milford MA

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution

How to Use TOF and Q-TOF Mass Spectrometers

Agilent s LC/MS Portfolio and Applications Examples

Qualification of Drug Product Contact Materials used in Small Volume Parenterals (SVP): Chemistry Considerations Edward J. Smith, Ph.D.

Increased Identification Coverage and Throughput for Complex Lipidomes

Research to Routine Workflows for Large and Small Molecules using the Q Exactive HR/MS

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data

New Methodologies for POPs Analysis using Orbitrap GC-MS in Official Food Control

Determination of red blood cell fatty acid profiles in clinical research

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

SCS Mass Spectrometry Laboratory

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Thermo Fisher Scientific Inc., San Jose, CA; Bristol Myers Squibb, Princeton, NJ. Vast Scientific, Boston, MA

USP <232> and <233> Understanding Your Path to Compliance with the New Elemental Impurity Chapters. Steve Wall Agilent Technologies

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Quantification with Proteome Discoverer. Bernard Delanghe

Edgar Naegele. Abstract

Supporting information

Advances in Hybrid Mass Spectrometry

LC/MS Method for Comprehensive Analysis of Plasma Lipids

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Determination of Copper in Green Olives using ICP-OES

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

Analysis of trace elements in nutraceuticals in compliance with USP chapter <2232> Elemental Contaminants in Dietary Supplements

Designing an Extractables and Leachables Study

New GCMS Applications

Thermo Scientific LCMS Solutions for Pesticide Analysis

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

CHAPTER-6 IDENTIFICATION, AND CHARACTERISATION OF DEGRADATION IMPURITY IN VALSARTAN TABLETS

Strengthening Results. Advanced Chromatography with Mass Detection

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

Sue D Antonio Application Chemist Cedar Creek, TX

Target Analyses in Parallel Reaction Monitoring Mode (PRM)

Mike Hinds, Royal Canadian Mint

ANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID:

Analyzing Trace-Level Impurities of a Pharmaceutical Intermediate Using an LCQ Fleet Ion Trap Mass Spectrometer and the Mass Frontier Software Package

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

UPLC-HRMS: A tool for multi-residue veterinary drug methods

EDXRF APPLICATION NOTE

Mass Spectrometry Infrastructure

Toxicology Screening of Whole Blood Extracts Using GC/Triple Quadrupole/MS

A unique tool for metabolite research Q Exactive GC coupled with IRMS (QE GC-IRMS)

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

DIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD

ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate

SIEVE 2.1 Proteomics Example

Lipidomic Analysis by UPLC-QTOF MS

Analysis of FAMEs Using Cold EI GC/MS for Enhanced Molecular Ion Selectivity

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Thermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS

Routine Analysis of Fortified Foods using the Agilent 7800 ICP-MS

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Rapid and Robust Detection of THC and Its Metabolites in Blood

Orbitrap ID-X Tribrid mass spectrometer. Transforming small molecule identification and characterization

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Innovations in Large Volume Injection

Identification of Haemoglobinopathies by LC/MS

ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine.

Transcription:

Analytical Workflow for Extractable and Leachable Impurities AAPS 2015 26 October 2015, Orlando FL Kyle D Silva The world leader in serving science

WHAT are EXTRACTABLES and LEACHABLES? 2

3 What is E&L testing for?

Areas of concern CONTAMINANT TOXICICITY DRUG EFFICACY Is there risk of harm to the patient? Is there impact on drug potency? 4

Extractables & Leachables EXTRACTABLE Chemical released from process equipment, packaging or delivery system; under laboratory extraction conditions. Process must not degrade or deform material. LEACHABLE Chemical that migrates from process equipment, packaging or delivery system; into drug formulation under normal usage conditions. Leachables are typically a subset of extractables. 5

Extractables versus Leachables testing EXTRACTABLE LEACHABLE Test the materials Test the product 6

Regulations There are as yet no single specific standards or guidance for extractables and leachables testing. 7

Extractables & Leachables Assessment Workflow Select Raw Material Risk Assessment Risk? No Extraction Study (Material) Leachable Study (Drug & Placebo) Yes >AET? Yes Toxicological Risk Assessment Yes >AET? No No Yes High Risk? No AET = Analytical Evaluation Threshold Establish E to L Relationship & Acceptance Criteria Assessment Complete 8

E&L Regulatory and method landscape National Regulators Methods & Advisory Bodies USP 1663 & 1664 Standardized Extractables Testing Protocol. Pharmaceutical Engineering 34 (2014) Industry Groups 9

BPOG Single-use System Extractables Test Guidelines Standardized Extractables Testing Protocol. Pharmaceutical Engineering 34 (2014) 10

Analysis of Extractables & Leachables GC-MS GC-HRMS Headspace EI & CI Library Volatile Impurities Semi- Volatile Impurities GC-MS GC-HRMS EI & CI Library ESI & APCI LC-UV LC-MS/MS LC-HRMS Library Non- Volatile Impurities Elemental Impurities ICP-MS ICP-OES 11

Our solution is complete for Extractables & Leachables Preparation Volatiles Semi-volatiles Non-Volatiles Elemental Consumables ASE 350 Chromeleon Trace 1300 GC TriPlus 300 ISQ GC-MS Chromeleon Q Exactive GC GC-MS/MS Trace 1300 GC TraceFinder Q Exactive LC-MS/MS Vanquish UHPLC ICS-5000 HPIC Compound Discoverer TraceFinder MZ Cloud icap Q ICP-MS icap 7000+ ICP-OES Qtegra ISDS MS Certified Vials Columns Ultra-pure GC Resolv & Optima LCMS Solvents Virtuoso 12

Experimental O-Ring Extractables Study 13

Pharmaceutical O-Rings extractables study 4 O-ring samples A Red B Brown C White D Black Blank (control) Solvents Water 5M NaCl 50% Ethanol 100% Ethanol 1% PS-80 0.5N NaOH 0.1M Phosphoric Acid 40 C for 30 days 14

O-ring Extractables Study Semi-volatiles Non-Volatiles Metals Q Exactive GC GC-MS/MS Trace 1310 GC TraceFinder Q Exactive LC- MS/MS Compound Discoverer TraceFinder MZ Cloud icap Q ICP-MS Qtegra ISDS 15

GC-MS instrument conditions TRACE 1310 GC Parameters Injection Volume (ml): 1 Liner Single gooseneck Inlet ( C): 280 Carrier Gas, (ml/min): He, 1.2 Oven Temperature Program: Temperature 1 ( o C): 40 Hold Time (min): 1 Temperature 2 ( o C): 320 Rate ( o C/min) 15 Hold Time (min): 10 Thermo Scientific Q Exactive GC Hybrid Quadrupole-Orbitrap GC-MS/MS System Thermo Scientific Trace 1310 GC Thermo Scientific TraceFinder Q Exactive GC MS Parameters Transfer line ( C): 280 Ionization type: EI Ion source( C): 230 Electron energy (ev): 70 Acquisition mode: Full scan Mass range (Da): 50-650 Mass resolution (FWHM): 60k Lockmass (m/z): 207.03235 16

Integration of 3 highly successful technologies TRACE 1310 GC rapid heat cycling unique modular injector and detector design 17

Integration of 3 highly successful technologies TSQ 8000 Series ExtractaBrite ion source technology Routine grade robustness Removable without breaking vacuum Patented RF lens protects ion guide and quads 18

Integration of 3 highly successful technologies Orbitrap mass analyzer technology Incredible HR/AM performance Highly regarded Q Exactive platform 19

Breakthrough in GC-MS capability Resolution Mass Accuracy Sensitivity Dynamic Range Up to 120,000 at m/z 200 < 1ppm ppt >6 orders Highest available Maximum selectivity Fast enough for GC! Every scan All concentrations In complex matrix In full scan High selectivity High spectral fidelity Excellent coverage in sample profiling Triple quad grade quantitation in full scan Across the mass range Everyday! 20

Scan speed and accurate mass error across a peak Ethyl octanoate m/z 129.0910 21

Results Semi-volatile extractables 22

Compound Discovery and Identification 1. Peak detection 2. Spectral deconvolution 3. Library searching (e.g. NIST, Wiley, custom) 4. % TIC explained using elemental composition and high resolution filtering with accurate mass 23

Peak Detection and Candidate Matching Deconvolve TIC Create clean spectrum Library search Candidate Compounds Acquired Library 24

High Resolution Filtering Candidate Compounds Subset formulae C 8 H 8 Cl 2 O 2 (m/z *Intensity) explained HRF Score = x 100% (m/z *Intensity) observed 25

Example results RT: 4.10-27.88 SM: 7B 100 5.66 Relative Abundance 90 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Blank control 4.78 20.64 21.02 21.86 22.45 23.25 24.83 26.44 20.03 19.59 7.65 19.16 6.66 8.84 17.88 10.33 11.65 16.62 12.80 13.82 Brown O-Ring 5.67 20.80 21.86 24.39 24.62 5.10 20.37 25.02 26.04 5.70 11.10 15.42 19.19 6 8 10 12 14 16 18 20 22 24 26 Time (min) 17.48 18.56 NL: 6.86E8 TIC MS 03June15_0 08 NL: 2.54E9 TIC MS 03june15_01 1 26

Step 1: Deconvolution of the data TraceFinder first performs an accurate mass deconvolution of the data. Extracts all of the peaks in the chromatogram. Provides a cleaned spectrum for library matching. 27

Step 2: Quickly isolate the peaks of interest 2051 peaks were extracted from the brown O-ring sample Heat Map indicates the peaks elevated in the sample. 28

Top 10 differential peaks in Brown O-ring Peaks list can also be sorted by fold difference compared with control to isolate the differential peaks that could be low or high intensity. 29

Step 3: Identify the compound searching NIST 14 26 Hits from NIST are sorted based on: Spectral matching High Resolution Filtering (HRF) score. 30

Step 3: Identify the compound searching NIST 14 Combined SI and HRF values give an overall score (%) to quickly and confidently identify the compound. Eliminates other hits that would be valid if only SI used. 31

Step 4: Fragments can be explained with < 1ppm mass accuracy 32

Identifying without a library hit? Confident ID comes from mass accuracy 33

Black O ring peak at 15.17 minutes no clear NIST hit No clear match with low score at 75.7% 34

EI & PCI spectra for peak at 15.17 mins. 35

No. of proposed formulae for m/z 324.13541 35 30 Top hit = C 20 H 20 O 4 25 No. proposed formulae 25 20 15 10 6 12 5 0 4 1 1 ppm1 3 ppm 5 ppm 10 ppm 20 ppm Elements used: C (1-30), H (1-60, N (1-5), O (1-5), P (1-2), S (1-2) 36

MS/MS m/z 325.14 to support proposed formula 08OCT15_01 #2053-2062 RT: 15.65-15.66 AV: 10 NL: 1.19E7 T: FTMS + p CI Full ms2 325.14@hcd10.00 [50.00-350.00] Relative Abundance 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 >13 fragments can be explained based on C 20 H 20 O 4 77.03894 105.03358 C 7 H 5 O = 105.03349 0.83676 ppm 117.07012 145.02854 C 9 H 5 O 2 = 145.02841 0.92080 ppm 161.90226 195.08049 C 14 H 11 O = 195.08044 0.24907 ppm 223.07545 C 15 H 11 O 2 = 223.07536 0.42975 ppm 251.10672 C 17 H 15 O 2 = 251.10666 0.26844 ppm 279.10166 C 18 H 15 O 3 = 279.10157 0.30906 ppm 60 80 100 120 140 160 180 200 220 240 260 280 300 m/z 37

Summary of identifications in Black and Brown O-rings Sample RT (min) Base Peak (m/z) Search Index HRF Compound Name Formula Base Peak Mass Accuracy (ppm) Molecular ion Mass Accuracy (ppm) Black O Ring 15.17 178.07754 No match No match Unknown C 20 H 20 O 4 0.88 0.66 15.29 178.07754 No match No match Unknown C 20 H 20 O 4 0.11 0.22 18.08 171.13806 673 99.965 Tetraethylene glycol bis (2 ethylhexanoate) C 24 H 46 O 7 0.64 23.47 219.17435 777 99.805 Irganox 1076 C 35 H 62 O 3 0.03 1.02 14.94 280.10939 536 99.8458 ethyl 1 hydroxy 2,3 diphenylcycloprop 2 ene 1 carboxylate C 18 H 16 O 3 0.39 0.39 16.50 126.09145 652 99.7409 9 Octadecenamide C 18 H 35 NO 0.87 0.63 Brown O Ring 17.48 277.07790 806 98.7 Triphenylphosphine oxide C 18 H 15 OP 0.85 0.06 15.42 183.03595 831 99.7455 Triphenylphosphine C 18 H 15 P 0.68 0.91 11.10 219.1743 796 99.7775 4 tert butyl 2,6 diisopropylphenol C 16 H 26 O 0.18 0.21 11.35 149.02341 831 98.4127 Diethyl phthalate C 12 H 14 O 4 0.60 0.9 13.57 185.04198 813 93.8 Diphenyl sulfide C 12 H 10 S 0.21 0.05 16.00 155.07025 690 100 di(butoxyethyl)adipate C 18 H 34 O 6 0.13 1.02 Peaks listed are significantly different compared to control. 38

Summary of identifications in White and Red O-rings Sample RT (min) Base Peak (m/z) Search Index HRF Compound Name Formula Base Peak Mass Accuracy (ppm) Molecular ion Mass Accuracy (ppm) White O Ring 11.93 263.20074 711 99.8611 1,4 Dihydrophenacetic acid, 3,5 di t butyl, ethyl ester C 18 H 30 O 2 0.72 0.43 7.65 101.02344 781 100 Butanedioic acid, diethyl ester C 8 H 14 O 4 0.54 Red O Ring 10.44 163.07549 775 99.6123 Ethanone, 1 [4 (1 hydroxy 1 methylethyl)phenyl C 11 H 14 O 2 0.85 0.38 15.09 87.044 740 99.8332 Methyl stearate C 19 H 38 O 2 1.26 0.06 16.00 155.07025 690 100 di(butoxyethyl)adipate C 18 H 34 O 6 0.13 1.02 Peaks listed are significantly different compared to control. 39

Results Non-Volatile extractables 40

LC-MS/MS instrument conditions Equipped with a HESI II ion source. Full scan MS and top3 datadependent HCD MS/MS data were collected. Resolutions of 17,500 and 70,000 Polarity switching. Thermo Scientific Q Exactive Plus Hybrid Quadrupole-Orbitrap LC-MS/MS System. Thermo Scientific UltiMate 3000 UHPLC System 41

Mass Accuracy with Polarity Switching (External Calibration) 1 positive + 1 negative scan in <1 second 42

MS Scanning Speeds to meet UHPLC Separation Resolution Setting: 35,000 Resolution Setting: 70,000 100 100 90 90 80 80 Relative Abundance 70 60 50 40 30 Relative Abundance 70 60 50 40 30 20 20 10 10 0 1.75 1.80 1.85 1.90 1.95 Time (min) 0 1.75 1.80 1.85 1.90 1.95 Time (min) Peakwidth (FWHM) ~ 1 sec Scans/peak = 21 Peakwidth (FWHM) ~ 1 sec Scans/peak = 11 43

Polarity Switching maintains High Mass Accuracy 100 90 O O P OH O (M+H) + 475.2964-1.5 ppm Positive (+) 80 Relative Abundance 70 60 50 40 30 C 28 H 43 O 4 P MF: 474.2899 476.2998 (M+NH 4 ) + 492.3229 (M+Na) + 497.2782 519.2603 20 10 0 498.2818 520.2639 506.3389 419.2335 513.2525 420 425 430 435 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525 530 m/z Relative Abundance 100 90 80 70 60 50 40 30 20 (M-H) - 473.2824-0.4 ppm 474.2857 Negative (-) 10 0 475.2889 420 425 430 435 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525 530 535 m/z 44

Data Analysis For Unknown Quanfirmation Thermo Scientific TraceFinder Software Thermo Scientific Compound Discoverer Thermo Scientific SIEVE Software Quantitation Deconvolution Searching Advanced Unknown Identification Metabolism Differential Analysis PCA Small Molecule Unknown ID & Quantification Spectral Interpretation Libraries & Mass Tables Validated Cloud Library Thermo Scientific Mass Frontier Software High-Resolution Accurate-Mass MS/MS Spectral Libraries MZ Cloud 45

Unknown analysis of small molecules Thermo Scientific Compound Discoverer Customizable node based small molecule structure analysis software CD v.1 is for known parent workflows structure analysis CD v.2 will include unknown workflows structure analysis (E&L). Coming end 2015. 46

Compound Discoverer Workflow Process Review results Report Elucidate structure 4 3 263.17499 C15 H23 N2 O2 [M-e]+1 Intensity [counts] (10^6) 2 245.16451 1 172.00601 C6 H6 N O3 S [M-e]+1 (+Oxidation) 189.10201 C11 H13 N2 O [M-e]+1 241.10005 C11 H17 N2 O2 S [M-e]+1 261.15948 C15 H21 N2 O2 [M-e]+1 163.06009 257.09500 208.09636 259.14423 237.19511 C11 H17 N2 O3 S [M-e]+1 172.07552 C11 H14 N O3 [M-e]+1 0 160 180 200 220 240 260 280 m/z 47

www.mzcloud.org mzcloud Free Advanced high resolution mass spectral database Search spectrum, name, structure, substructure, and m/z Identify compounds even when they are not present in the library through substructure search 48

High Resolution E&L Database Contains >1200 common E&L related compounds. Works with TraceFinder and Compound Discoverer for targeted screening. New E&L related compounds are added frequently. 49

O-Ring Extractables - Water E:\Parker-O-Ring Leachable\WFI_1 06/24/15 00:17:23 Accucore C18 150X2.1 2.6 um A: H2O/0.1% FA B: ACN/0.1% FA WFI Control RT: 0.0-56.0 Relative Abundance 300000000 200000000 100000000 300000000 200000000 100000000 300000000 200000000 100000000 300000000 200000000 100000000 300000000 200000000 100000000 SM: 5G Control 1.8 2.7 5.0 5.2 9.2 10.9 12.1 13.7 15.6 17.5 20.2 21.7 24.3 25.2 27.0 28.6 31.1 32.8 34.3 36.0 37.7 40.6 41.5 43.5 46.5 49.2 50.1 51.5 55.0 12.6 10.1 13.8 9.9 5.2 14.0 9.2 9.0 0.2 3.0 5.0 15.4 16.0 18.9 21.5 23.4 25.2 27.0 28.7 30.5 32.8 34.0 37.3 38.5 41.2 42.5 44.4 47.8 48.7 50.7 51.6 54.0 21.5 Red Brown 2.0 2.9 4.2 5.7 8.3 8.9 12.0 14.5 14.7 19.6 19.8 22.5 25.2 27.0 28.5 30.7 32.8 33.9 35.6 37.4 39.6 42.0 42.9 46.6 48.5 49.3 50.5 53.5 White 0.2 3.3 3.7 5.7 6.7 9.9 11.0 13.5 15.6 17.4 18.3 21.3 23.5 25.2 27.0 29.3 31.2 32.8 35.0 38.1 41.5 42.5 46.5 48.3 49.5 51.3 52.4 54.3 10.8 Black 11.9 3.2 6.7 9.8 12.6 30.2 1.0 3.5 9.0 17.0 17.3 17.5 21.1 22.8 25.2 27.0 32.8 34.1 35.8 37.7 41.6 42.5 46.5 48.7 49.8 50.9 52.6 55.6 0 5 10 15 20 25 30 35 40 45 50 55 Time (min) NL: 3.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS WFI_1 NL: 3.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS a_red_h2o_01 NL: 3.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS b_brown_h2o_1 NL: 3.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS c_white_h2o_1 NL: 3.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS d_black_h2o_1 50

O-Ring Extractables 5M NaCl d_black_nacl_2 06/27/15 22:06:23 Accucore C18 150X2.1 2.6 um A: H2O/0.1% FA B: ACN/0.1% FA RT: 3.6-49.9 Relative Abundance 100000000 80000000 60000000 40000000 20000000 100000000 80000000 60000000 40000000 20000000 100000000 80000000 60000000 40000000 20000000 100000000 80000000 60000000 40000000 20000000 100000000 80000000 60000000 40000000 20000000 SM: 5G 17.5 24.3 25.2 27.0 27.5 30.3 32.8 35.0 37.6 40.7 41.4 43.0 46.0 47.9 48.7 NL: 1.00E8 Base Peak m/z= 10.2 13.9 50.0000-1750.0000 F: FTMS + p 9.9 Red ESI Full ms [125.00-1700.00] - m/z= 391.2810-391.2850 MS 9.1 14.0 a_red_nacl_2 6.2 8.7 11.5 5.0 6.8 16.4 17.5 24.1 25.2 27.0 27.4 31.4 32.8 33.3 37.2 38.2 40.2 41.9 43.8 46.2 48.4 49.6 NL: 1.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p Brown ESI Full ms [125.00-1700.00] - 21.5 m/z= 391.2810-391.2850 MS b_brown_nacl_2 19.8 14.7 3.8 12.6 17.5 24.3 25.2 27.0 27.4 32.1 32.8 33.1 35.8 38.0 39.3 42.5 43.2 47.3 48.2 49.9 NL: 1.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p White ESI Full ms [125.00-1700.00] - m/z= 391.2810-391.2850 MS c_white_nacl_2 4.0 17.5 24.1 25.2 26.9 27.2 31.7 32.8 35.4 37.3 40.1 41.7 44.6 46.1 48.4 49.4 NL: 1.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p Black ESI Full ms [125.00-1700.00] - m/z= 391.2810-391.2850 MS d_black_nacl_2 13.9 10.9 14.0 23.7 3.8 4.0 8.1 10.3 12.6 7.8 14.3 16.5 18.3 19.6 22.0 25.2 26.9 27.5 30.8 32.8 35.6 36.4 37.9 40.3 41.4 42.3 45.3 48.0 48.8 5 10 15 20 25 30 35 40 45 Time (min) Control NL: 1.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] - m/z= 391.2810-391.2850 MS 5M_NaCl_2 51

O-Ring Extractables 50% Ethanol E:\Parker-O-Ring Leachable\50EtOH_2 06/25/15 04:50:58 Accucore C18 150X2.1 2.6 um A: H2O/0.1% FA B: ACN/0.1% FA WFI Control RT: 3.1-52.5 600000000 400000000 200000000 SM: 5G Control NL: 6.00E8 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS 50EtOH_2 Relative Abundance 600000000 400000000 200000000 600000000 400000000 200000000 600000000 400000000 200000000 600000000 400000000 200000000 3.3 25.2 27.0 32.9 48.9 50.4 19.8 3.3 14.7 22.5 25.2 27.0 32.8 46.7 49.8 50.5 3.3 22.5 23.7 25.2 27.0 27.8 32.9 34.3 48.6 51.4 Red White 40.8 16.8 30.6 43.1 44.3 10.8 11.3 23.7 28.7 31.6 37.0 38.5 3.3 6.3 10.0 13.8 16.4 17.4 21.5 22.6 25.2 26.4 32.1 34.7 46.7 47.2 50.2 50.9 Black 5 10 15 20 25 30 35 40 45 50 Time (min) 39.2 39.9 NL: 6.00E8 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS a_red_50etoh_2 12.6 32.1 13.8 34.1 10.0 14.0 21.5 34.2 4.7 5.2 11.5 23.7 26.8 31.6 39.2 39.6 6.1 8.8 16.4 18.9 26.4 28.7 35.8 42.6 44.3 46.8 49.4 50.1 51.2 NL: 6.00E8 21.5 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS Brown b_brown_50etoh_2 NL: 6.00E8 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS c_white_h2o_2 NL: 6.00E8 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS d_black_50etoh_2 52

O-Ring Extractables 100% Ethanol E:\Parker-O-Ring Leachable\100EtOH_2 06/26/15 04:17:58 Accucore C18 150X2.1 2.6 um A: H2O/0.1% FA B: ACN/0.1% FA WFI Control RT: 0.0-56.0 Relative Abundance 800000000 600000000 400000000 200000000 800000000 600000000 400000000 200000000 800000000 600000000 400000000 200000000 800000000 600000000 400000000 200000000 800000000 600000000 400000000 200000000 SM: 5G 3.3 25.2 27.0 32.8 Control 12.5 31.1 31.6 32.1 46.8 13.8 21.5 34.2 39.6 3.3 9.7 9.9 16.4 19.6 22.0 37.2 39.8 43.2 44.3 50.2 5.3 23.7 28.7 47.2 50.6 21.5 19.7 3.3 14.7 22.5 25.2 27.0 32.8 46.7 48.9 19.7 21.5 3.3 14.6 22.5 25.2 26.9 32.8 46.8 50.2 Red Brown White Black 30.6 43.1 44.3 10.8 40.9 23.7 38.5 47.2 10.6 11.3 28.7 46.8 12.5 16.9 18.3 32.1 37.1 51.5 3.3 5.1 6.6 8.8 22.4 23.4 25.2 27.0 33.7 46.5 50.0 0 5 10 15 20 25 30 35 40 45 50 55 Time (min) 40.0 NL: 8.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS 100EtOH_2 NL: 8.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS a_red_100etoh_2 NL: 8.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS b_brown_50etoh_3 NL: 8.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS b_brown_100etoh_2 NL: 8.00E8 Base Peak m/z= 50.0000-1750.0000 F: FTMS + p ESI Full ms [125.00-1700.00] MS d_black_100etoh_2 53

BPI+ of Black O-ring in Four Extraction Solutions d_black_50etoh_2 06/25/15 23:12:07 Accucore C18 150X2.1 2.6 um A: H2O/0.1% FA B: ACN/0.1% FA WFI Control RT: 3.8-50.3 1000000000 800000000 600000000 400000000 Waters NL: 1.00E9 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS D_Black_H2O_2 Relative Abundance 200000000 0 1000000000 800000000 600000000 400000000 200000000 0 1000000000 800000000 600000000 10.8 6.4 9.0 9.8 11.9 12.5 17.3 25.2 27.0 30.2 32.8 30.1 39.2 39.3 39.9 50% EtOH 16.8 40.8 30.6 43.0 44.3 10.8 11.3 23.7 28.7 31.6 38.5 44.3 6.3 10.1 13.8 16.4 17.4 18.9 21.5 22.6 26.4 33.7 37.0 25.2 47.2 47.3 39.2 30.1 39.3 40.0 100% EtOH NL: 1.00E9 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS d_black_50etoh_2 NL: 1.00E9 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS d_black_100etoh_2 400000000 200000000 0 1000000000 800000000 600000000 30.6 43.0 44.3 10.8 40.8 23.7 38.6 47.2 10.7 11.4 12.0 28.7 46.7 16.8 32.1 37.0 41.0 5.1 6.6 9.3 9.9 16.1 18.3 23.4 25.2 27.0 33.7 36.3 46.5 50.0 NL: 1.00E9 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS d_black_nacl_2 5 M NaCl 400000000 200000000 0 3.9 5.3 8.1 9.1 10.9 12.6 13.9 16.5 18.3 23.7 25.2 26.9 32.8 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 Time (min) 54

Powerful Top3 MS/MS for structural elucidation B_Brown_50EtOH_1 08/10/15 19:58:00 Accucore C18 150X2.1 2.6 um A: H2O/0.1% FA B: ACN/0.1% FA WFI Control Brown O-Ring 50% EtOH RT: 16.4-24.4 100 90 80 Relative Abundance 70 60 50 40 30 21.5 NL: 1.53E9 Base Peak F: FTMS + p ESI Full ms [125.00-1700.00] MS B_Brown_50EtOH _1 20 19.7 10 0 16.5 17.0 17.5 18.0 18.5 19.0 19.5 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 Time (min) B_Brown_50EtOH_1 #4379 RT: 19.75 AV: 1 NL: 2.16E8 T: FTMS + p ESI Full ms [125.00-1700.00] 100 Full Scan (+) 90 80 (M+H) + 353.1451 B_Brown_50EtOH_1 #4803 RT: 21.55 AV: 1 NL: 1.52E9 T: FTMS + p ESI Full ms [125.00-1700.00] 100 90 80 (M+H) + 279.0933 O P Relative Abundance 70 60 50 40 30 20 10 P 354.1482 C 25 H 21 P 1 352.13809 Error: -0.7 ppm Relative Abundance 70 60 50 40 30 20 10 280.0962 C 18 H 15 P 1 278.08605 Error: -0.1 ppm 0 150 200 250 300 350 400 450 500 550 600 0 150 200 250 300 350 400 450 500 m/z m/z B_Brown_50EtOH_1 #4364 RT: 19.70 AV: 1 NL: 2.98E7 T: FTMS + p ESI d Full ms2 353.15@hcd40.00 [50.00-380.00] 100 MS/MS (+) 90 353.1448 B_Brown_50EtOH_1 #4780 RT: 21.46 AV: 1 NL: 4.62E7 T: FTMS + p ESI d Full ms2 279.09@hcd40.00 [50.00-305.00] 100 90 279.0930 80 80 Relative Abundance 70 60 50 40 30 91.0547 Relative Abundance 70 60 50 40 30 219.0567 20 10 0 262.0903 294.0800 108.0125 185.0512 126.0234 158.7920 327.3946 79.0550 201.0468 354.1495 80 200 220 360 60 100 120 140 160 180 240 260 280 300 320 340 380 20 10 0 201.0462 173.0512 95.0496 141.0099 77.0400 183.0357 69.3540 128.0618 220.0595 280.0970 60 80 100 120 140 160 180 200 220 240 260 280 300 m/z m/z 55

Compound Discoverer Workflow for O-Ring leachables Workflow Nodes Workflow Tree 56

Automated Identification Compound Discoverer 57

Data are directly mirror-plotted versus mzcloud 58

Parallel identification through multiple reference sources mzcloud Library Spectrum ChemSpider Search Results E&L Library Results 59

Components identified confidently Compound Discoverer allows rapid identification with confident searching of multiple databases in parallel Targeted search compounds can be easily confirmed. High confidence Orbitrap data (<1ppm) combine with mzcloud libraries 60

Results Elemental extractables 61

Elemental analysis Thermo Scientific icap Q Series ICP-MS Qcell technology for interference reduction Sub ppt detection limits >9 orders dynamic range Robust design to compete with almost any sample matrix Fully compliant Thermo Scientific Qtegra ISDS software Automatic- dilution Full USP 233 & ICH Q3D method capabilities 62

icap Q ICP-MS Instrument Configuration Extracts: Water - Analyzed directly 5M NaCl - Analyzed directly 50% Ethanol - Analyzed directly 100% Ethanol - EtOH evaporated 50%, re-dissolved in ultra-pure water Measurement Mode: KED; pure He @ 4.5 ml min-1 Internal standard added online 30ppb Sc, 10 ppb Ga, Y and Lu in 2% HNO3 (4% EtOH added for 50% EtOH samples) All samples were acidified before analysis: 1mL sample, 0.5 ml 65% HNO3, 3.5 ml UPW 63

Analysis and QC checks following USP 233 Calibration Range: between 1000-fold and 10-fold dilution of lower limit R 2 better than 0.99 Sensitivity Verification: Analysis @ 0.5x lower limit ±30% of prepared concentration Accuracy Check: Spike recovery of a 0.2 mg/l solution after complete sample acidification routine ±20% of expected concentration Drift Check: Standard 2 (500x dilution) was analyzed every 10 samples ±30% of prepared concentration Quality data, automatically tested 64

Results Water and 5M NaCl Reported is concentration in undiluted sample solution Most elements were not detectable Water 5M NaCl 63 Cu 66 Zn 111 Cd 123 Sb 208 Pb 56 Fe 63 Cu 66 Zn 75 As 123 Sb 208 Pb ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 Black - 0.64 0.022-0.03 0.05 0.011 0.71-0.002 0.001 White 0.007 - - 0.002 0.09 0.007 0.008 0.08-0.009 0.005 Brown - - - - - 0.015-0.005-0.007 0.0002 Red 0.004-0.006-0.02 0.01 0.018 0.026 0.1 0.04-65

Results 100% EtOH Reported is concentration in undiluted sample solution Most elements were not detectable 100% EtOH 50% EtOH 63 Cu 66 Zn 111 Cd 123 Sb 208 Pb 63 Cu 66 Zn 111 Cd 123 Sb 208 Pb ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 ng ml -1 E36092-0.03 - - - - 0.3 - - - FF3502 - - - 0.41 - - - - - - HF355-2 - - - - - - - - - - S 11382 - - - - - - - - - - 66

Drift Check 6.5 hour run, 100 samples, 11 drift checks Analyte Av. Recovery [%] RSD [%] Analyte Av. Recovery [%] RSD [%] 7Li 100.9 4.2 103Rh 99.2 1.6 9Be 100.9 9.2 51V 99.0 1.2 52Cr 99.2 1.8 55Mn 92.9 0.8 59Co 95.0 0.7 60Ni 98.5 1.3 63Cu 99.4 1.3 66Zn 97.6 0.8 75As 100.1 4.8 78Se 97.7 2.7 95Mo 97.6 1.4 105Pd 95.7 3.1 111Cd 97.0 4.0 115In 93.7 1.0 121Sb 102.0 2.5 182W 100.0 2.6 189Os 95.0 2.6 193Ir 100.3 1.5 195Pt 99.4 1.4 202Hg 96.4 1.7 205Tl 97.6 12.6 208Pb 98.1 1.3 101Ru 97.6 1.6 67

Summary Extractable workflow 68

Summary GC & LC Orbitrap have superior HRAM, enabling confident identification of extractable unknowns. Empowering software workflows simplify and automate the process of complex identification. Free cloud libraries allow quick qualification of unknowns. Analysis of elemental impurities at the lowest levels is possible with icap Q. 69

Webinars SAVE THE DATES 1. Testing for leachables in pharmaceutical contact closure materials; a complete ICP-MS, GC-MS & LC-MS workflow. Wednesday 4th November 2015 10:30 EST 16:30 CET Dr. Andrew Feilden, Chemistry Operations Director, Smithers Rapra 2. Using GC & LC Orbitrap mass spectrometry to confidently identify leached packaging and process impurities. Wednesday 2nd December 2015 10:30 EST 16:30 CET Dr. Kate Comstock & Mr. Dominic Roberts, Thermo Fisher Scientific bit.ly/identifyleachables 70

E&L Resources Webinars Applications Blogs Regulatory updates White papers And more www.thermoscientific.com/leachables 71

Thank you Andrew Feilden, Smithers Rapra Kate Comstock Daniel Kutscher Dom Roberts 72