QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

Similar documents
QUICK START GUIDE SENTIERO DESKTOP DIAGNOSTIC (WHITE HOUSING)

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

Bio-logic AuDX PRO FLEX Quick start Quick start guide

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Bio-logic AuDX PRO FLEX Diagnostic OAE and audiometry Quick start guide

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

by Maico Diagnostics

Handheld OAE-Tympanometry Combination System

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Neuro-Audio Version 2010

Biologic AuDX/Welch Allyn Quick Screen Instructions ECHO Training/Workshops

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Oscilla - excellence since 1960

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

Reliable, flexible & precise

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

ERO SCAN. Otoacoustic Emission Testing

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

Dosimeter Setting Device

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

The following describes general use of ELIOS device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

On the following pages you ll find a few more specific features to consider in evaluating OAE equipment.

TruLink Hearing Control App User Guide

Quick guide to connectivity and the Interton Sound app

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Sleep Apnea Therapy Software User Manual

TRAINING MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

Step-by-Step RECD Guide

User's Manual Tympanometer Earscan ES-TRAM Document ID: PUB-114 Revision B

AURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04

AMBCO 1000+P AUDIOMETER

MI 44 Operating Instructions

Beltone Solus Pro 1.9 Fitting Guide

User Guide. For Jacoti Hearing Center Version 1.1. Manufacture Year 2016

For Electric Personal Dosimete Dose-i

SHOEBOX Audiometry Pro. Quickstart Guide. SHOEBOX Audiometry Pro

Additional Information Titan

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System

Fitting System Instructions for Use

Operating Instructions MI 24

Dosimeter Setting Device System NRZ

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

AMBCO 2500 AUDIOMETER SYSTEM WITH FIVE YEAR WARRANTY

USING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User

General Catalogue. Product Line for Hearing Screening & Diagnostics

Hearing Control App User Guide

MI 26 Operating Instructions

Operating Instructions MAICO MI 26

Data Management System (DMS) User Guide

CMS-50E Instructions by Cooper Medical Supplies (These instructions are to supplement the manufacturer s user manual not to replace it!

Diagnostic Impedance & Audiometry in one solution

IHearYou The award-winning self-fit hearing aid system. A detailed guide (April 2018).

ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT.

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

Welch Allyn OAE Hearing Screener. Directions for use

ChildFit. Widex Baby. Compass quick guide

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

How to Use the myhearing App on Apple/iOS devices

Sanako Lab 100 STS USER GUIDE

Instructions for Use. Oscilla TSM400 Screening Tympanometer. Specifications are subject to change without notice ID: 6795 / ver.

Quick Guide Binaural REM

AudioConsole. User Guide. Doc. No EN/01 Part No EN

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

EA 87. Clinical Impedance. Audiometer. User Manual

the truly automated all-in-one hearing screener

Software Version 2.0. User s Guide

How to use AutoFit (IMC2) How to use AutoFit (IMC2)

BIO-LOGIC PRO NAVIGATOR TRUSTED TECHNOLOGY. RELIABLE RESULTS.

User Guide. For Jacoti Hearing Center Pro Version 1.0. Manufacture Year 2017

MADSEN AccuScreen OAE & ABR Screener

Enzyme Analysis using Tyrosinase. Evaluation copy

ALL INDIA INSTITUTE OF SPEECH AND HEARING, MYSURU E-PROCUREMENT NOTIFICATION FOR SUPPLY OF

Multiple Diagnostic Interface (MDI) User Guide

Technical specifications, manufacturer s data. Senti & Sentiero

SOFTWARE INSTRUCTION MANUAL

Data Management System (DMS) User Guide

USING THE MINIMED 670G SYSTEM

MA 25 Operating Manual

Audiological Bulletin no. 46

Transcription:

DEVICE CONNECTORS On/off button Power supply USB cable Headphones or second transducer Air pump USB Label Patient response Probe cable printer button START MENU Please note that not all Start Menu options will be available depending on the configuration of your device Current time Battery status Customize settings Select patient Turn off device Additional information on options for current screen TESTING TYMPANOMETRY Connect the probe to the red connector and the air cable to the pump connector. From the start menu, select the Tymp: Tymp+1kHz button. Select the test ear by pressing either the Right or Left button. Cartoon mode will show an airplane on the screen during the tympanometry test. For web description SOD05, connect a second transducer to the blue connector for Contralateral Reflex testing. Second transducer Air pump Probe 100800-02_Sentiero Desktop OAE + Tymp Screener Quick Start Guide_Rev 2 Page 1 of 7

Select the appropriate ear tip size and place it on the probe tip. Insert the probe in the ear making sure that the ear tip fits tightly into the ear canal. TYMPANOMETRY TEST SCREEN The system will first check the probe fit and wait for the pressure build up. The LED light on the probe will pulse at a steady pace to indicate a correct fit. During the test, if the probe fit is not correct, the LED light will blink at a fast pace and an error message prompting you to retry or cancel the test will appear on the screen. Once a proper seal has been obtained, the test will proceed. A tympanometry test will be performed, followed by a reflex measurement. Tympanometry result Reflex test in progress Reflex threshold found Overall Reflex test result 100800-02_Sentiero Desktop OAE + Tymp Screener Quick Start Guide_Rev 2 Page 2 of 7

DISTORTION PRODUCT OTOACUSTIC EMISSIONS (DPOAE) SCREENING Select either the Screening or the Standard button from the start menu and connect the probe to the red connector. Select the appropriate ear tip size and place it on the probe tip. Insert the probe in the ear making sure that the ear tip fits tightly into the ear canal. Select the test ear by pressing either the Right or Left button. Cartoon mode will start the test showing a cartoon instead of the progress bar. A calibration will be performed prior to measurement. A green light indicates successful calibration. After successful ear probe calibration, the test will start automatically. Probe fit override for patients with PE tubes or middle ear perforations Progress for each tested frequency Overall test progress Noise floor level 100800-02_Sentiero Desktop OAE + Tymp Screener Quick Start Guide_Rev 2 Page 3 of 7

DPOAE SCREENING TEST RESULTS BASIC RESULTS VIEW Please note that the initial result screen depends on the module settings in "DPOAE Preferences" If the required criteria were met, the result will be PASS. If not, it will be REFER. Print results to a label or to a pdf file or full page report on PC. Note: These circles indicate that other screens are available to view. Swipe your finger right or left to get other views. DETAILED RESULTS VIEW Red or blue bars indicate response, grey bars indicate noise Outcome for each test sorted by f2 and L2 Numeric values shown in table format 100800-02_Sentiero Desktop OAE + Tymp Screener Quick Start Guide_Rev 2 Page 4 of 7

AUDIOMETRY (Available only on web description SOD05) Connect the headphones to the blue connector and select the Audiometry: Screening button from the start menu. Select the ear on which you want to start the test. AUDIOMETRY TEST SCREEN Stimulus on indicator Select the stimulus levels Select the frequency Press to present the stimulus Stop test Additional information about options for current screen Select the ear to test Select the type of stimulus: pure tone pulsed tone or warble 100800-02_Sentiero Desktop OAE + Tymp Screener Quick Start Guide_Rev 2 Page 5 of 7

As you present the stimulus, the current level will be displayed in the corresponding square. Once the hearing status for a frequency has been identified, move on to the next frequency. Tapping twice on a square will display NR (no response). Tap three times to get back to blank square. Once all frequencies have been tested for one ear, you can test the other ear. When the test is finished, press the Stop button. You can add the patient s personal data, and save on the device, print to a label (a label printer is required) or print to a pdf file or full page report on PC. 100800-02_Sentiero Desktop OAE + Tymp Screener Quick Start Guide_Rev 2 Page 6 of 7

Quick Guide Information Release date: 2017-01-12 Revision: 02 Valid from: Firmware Rev. 2.1, Mira PC Software Rev. 1.6.4 Applies to: Model: SOD100497, web description SOD04 and SOD05 All mentioned items, products, brands and trademarks are registered or owned by the mentioned companies. All information, illustrations, and specifications provided within this manual are based on the latest product information available at the time of publication. PATH medical reserves the right to make changes at any time without notice. Please note that not all products displayed on our webpage or advertising materials are available in all territories. Please contact your local distributor or PATH medical for further information. The latest revision of the Quick Start Guide is available online at www.pathme.de/download. Errors and omissions excepted. Copyright Notice No part of this manual may be reproduced, translated, stored, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of PATH medical GmbH. Copyright 2016 PATH medical GmbH PATH medical GmbH Landsberger Straße 65 82110 Germering Germany Tel.: +49 89 800 76 502 Fax: +49 89 800 76 503 Internet: www.pathme.de 100800-02_Sentiero Desktop OAE + Tymp Screener Quick Start Guide_Rev 2 Page 7 of 7