Improve Protein Analysis with the New, Mass Spectrometry- Compatible ProteasMAX Surfactant

Similar documents
ProteaseMAX Surfactant, Trypsin Enhancer

AccuMAP Low ph Protein Digestion Kits

Babu Antharavally, Ryan Bomgarden, and John Rogers Thermo Fisher Scientific, Rockford, IL

Trypsin Mass Spectrometry Grade

DetergentOUT Tween. DetergentOUT GBS10. OrgoSol DetergentOUT

Nature Methods: doi: /nmeth.3177

PosterREPRINT A NOVEL APPROACH TO MALDI-TOF-MS SAMPLE PREPARATION. Presented at ABRF 2002, Austin, Texas, USA, 9th - 12th March 2002.

Multiplex Protein Quantitation using itraq Reagents in a Gel-Based Workflow

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

TECHNICAL BULLETIN. R 2 GlcNAcβ1 4GlcNAcβ1 Asn

Trypsin Digestion Mix

In-Solution Digestion for proteomics

DetergentOUT Detergent Removal Systems

Characterization of Disulfide Linkages in Proteins by 193 nm Ultraviolet Photodissociation (UVPD) Mass Spectrometry. Supporting Information

Universal sample preparation method for proteome analysis

Agilent Protein In-Gel Tryptic Digestion Kit

Proteomics Grade. Protocol. Catalog # Agilent Technologies. Research Use Only. Not for use in Diagnostic Procedures. Version A, January 2010

DetergentOUT GBS10 Spin Plates

Lecture 3. Tandem MS & Protein Sequencing

Enhancing Sequence Coverage in Proteomics Studies by Using a Combination of Proteolytic Enzymes

Double charge of 33kD peak A1 A2 B1 B2 M2+ M/z. ABRF Proteomics Research Group - Qualitative Proteomics Study Identifier Number 14146

SMART Digest Kit Facilitating perfect digestion

Protein Identification and Phosphorylation Site Determination by de novo sequencing using PepFrag TM MALDI-Sequencing kit

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry

Comparison of mass spectrometers performances

Mass Spectrometry. Mass spectrometer MALDI-TOF ESI/MS/MS. Basic components. Ionization source Mass analyzer Detector

Microalbuminuric Diabetic patients N=18

Biological Mass spectrometry in Protein Chemistry

In-Gel Tryptic Digestion Kit

Peptide sequencing using chemically assisted fragmentation (CAF) and Ettan MALDI-ToF Pro mass spectrometry

Mass Spectrometry. - Introduction - Ion sources & sample introduction - Mass analyzers - Basics of biomolecule MS - Applications

Sequence Identification And Spatial Distribution of Rat Brain Tryptic Peptides Using MALDI Mass Spectrometric Imaging

Mass Spectrometry and Proteomics - Lecture 4 - Matthias Trost Newcastle University

Supplementary material: Materials and suppliers

SUPPLEMENTARY MATERIAL

Faster Mass Spec: Same-Day Sample Prep Now a Reality. Michael M. Rosenblatt, Ph.D.

Chemical Biology, Option II Mechanism Based Proteomic Tagging Case History CH1

Mammalian Membrane Protein Extraction Kit

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

The distribution of log 2 ratio (H/L) for quantified peptides. cleavage sites in each bin of log 2 ratio of quantified. peptides

SUPPLEMENTAL INFORMATION

Systematic analysis of protein-detergent complexes applying dynamic light scattering to optimize solutions for crystallization trials

MALDI-TOF. Introduction. Schematic and Theory of MALDI

Supporting information

Shotgun Proteomics MS/MS. Protein Mixture. proteolysis. Peptide Mixture. Time. Abundance. Abundance. m/z. Abundance. m/z 2. Abundance.

(III) MALDI instrumentation

Development of a Human Cell-Free Expression System to Generate Stable-Isotope-Labeled Protein Standards for Quantitative Mass Spectrometry

Up to now, gel electrophoresis remains the most powerful

Supporting Information. Post translational Modifications of Serotonin Type 4 Receptor Heterologously Expressed in. Mouse Rod Cells

PRODUCT: RNAzol BD for Blood May 2014 Catalog No: RB 192 Storage: Store at room temperature

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Biological Mass Spectrometry. April 30, 2014

Work-flow: protein sample preparation Precipitation methods Removal of interfering substances Specific examples:

SCS MOLECULAR WEIGHT MARKERS 2,500-17,000 Caltons

Learning Objectives. Overview of topics to be discussed 10/25/2013 HIGH RESOLUTION MASS SPECTROMETRY (HRMS) IN DISCOVERY PROTEOMICS

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

ab Glycated Protein Detection Kit

Broad Spectrum Protease Inhibitor Cocktail

Structural Characterization of Prion-like Conformational Changes of the Neuronal Isoform of Aplysia CPEB

About the Kits...2 Description 2 Components 3 Storage 3. Factors That Influence Factor Xa Activity... 4

Application Note # ET-17 / MT-99 Characterization of the N-glycosylation Pattern of Antibodies by ESI - and MALDI mass spectrometry

Proteomics of body liquids as a source for potential methods for medical diagnostics Prof. Dr. Evgeny Nikolaev

Supplementary Figure 1. Method development.

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

New Instruments and Services

Gel-based proteomics analysis of starving mouse pancreatic beta-cell insulinoma (MIN6) prior to glucose stimulation

Supporting Information

Overview of the Expressway Cell-Free Expression Systems. Expressway Mini Cell-Free Expression System

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Automating Mass Spectrometry-Based Quantitative Glycomics using Tandem Mass Tag (TMT) Reagents with SimGlycan

NIH Public Access Author Manuscript J Proteome Res. Author manuscript; available in PMC 2014 July 05.

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

for the Identification of Phosphorylated Peptides

Fig.S1 ESI-MS spectrum of reaction of ApA and THPTb after 16 h.

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

Purification of Glucagon3 Interleukin-2 Fusion Protein Derived from E. coli

ab Membrane Fractionation Kit Instructions for Use For the rapid and simple separation of membrane, cytosolic and nuclear cellular fractions.

Nature Biotechnology: doi: /nbt Supplementary Figure 1

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

TECHNICAL BULLETIN. PhosDecor Fluorescent Phosphoprotein In-Gel Detection Kit. Catalog Number PDECOR Storage Temperature 2 8 C

REDOX PROTEOMICS. Roman Zubarev.

Operating Instructions

The Detection of Allergens in Food Products with LC-MS

5 Identification of Binding Partners of the Annexin A2 / P11 Complex by Chemical Cross-Linking

PosterREPRINT INTRODUCTION. 2-D PAGE of Mouse Liver Samples. 2-D PAGE of E.coli Samples. Digestion / Cleanup. EXPERIMENTAL 1-D PAGE of BSA Samples

Protein and peptide separations,

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Chapter 3. Structure of Enzymes. Enzyme Engineering

Antoine Bouchoux, Pierre-Emerson Cayemitte, Julien Jardin, Geneviève Gésan-Guiziou, and Bernard Cabane

SUNY UPSTATE MEDICAL UNIVERSITY PROTEOMICS CORE

Supplementary Information. Top-down/bottom-up mass spectrometry workflow using dissolvable polyacrylamide gels

Supplementary Materials for

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

PosterREPRINT AN AUTOMATED METHOD TO SELF-CALIBRATE AND REJECT NOISE FROM MALDI PEPTIDE MASS FINGERPRINT SPECTRA

The N-terminal loop of IRAK-4 death domain regulates ordered assembly of the Myddosome signalling scaffold

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Transcription:

Improve Protein Analysis with the New, Mass Spectrometry- Compatible Surfactant ABSTRACT Incomplete solubilization and digestion and poor peptide recovery are frequent limitations in protein sample preparation for mass spectrometry (MS) analysis. Additives such as SDS or urea can improve protein solubilization and denaturation, but they tend to have negative effects on digestion and MS analysis. Here we present a novel acid- and thermo-labile surfactant, Surfactant, that improves solubilization, digestion and peptide recovery while avoiding negative effects observed with common solubilizing agents. The surfactant is designed to degrade over the course of a typical sample preparation protocol, generating zwitterionic and neutral species that do not interfere with MS. The improved solubilization properties of the surfactant allowed us to solubilize hydrophobic membrane proteins at room temperature within 1 hour. 2D LC-MS/MS analysis of mouse membrane proteome demonstrated a 70% increase in proteome coverage when the surfactant was added to the sample preparation protocol as a complementary solubilizing agent to urea. We observed up to a 30-fold increase in the rate of proteolysis in trypsin digestion of myoglobin in the presence of the surfactant. In-gel digestion showed up to 1.8-fold increase in protein coverage and up to 6.9-fold increase in MASCOT score. Long peptides in the range of 2,500 4,000 Da, which typically are poorly recovered following in-gel digestion, were present in quantities sufficient for MS/MS analysis. Experiments with model peptides and protein showed that the surfactant also minimizes the loss of peptides and proteins due to adsorption onto laboratory plasticware. Sergei Saveliev 1, Daniel Simpson 1, William Daily 2, Carolyn Woodroofe 2, Dieter Klaubert 2, Grzegorz Sabat 3, Robert Bulliet 1, and Keith V. Wood 1, 1 Promega Corporation, 2 Promega Biosciences, 3 Mass Spectrometry Facility, Biotechnology Center, University of Wisconsin-Madison. Surfactant: SURFace ACTive AgeNT. Common examples of surfactants are soap-like detergents including SDS and Triton X-100. INTRODUCTION Advances in mass spectrometry (MS) instrumentation and computational data analysis have driven a transformation in protein analysis, expanding the use of MS into applications such as protein:protein interaction, proteomic profiling, biomarker discovery and analysis of post-translational modification. While MS instrumentation has become increasingly powerful, the limitations on sample protein preparation for analysis have remained relatively unchanged. These limitations include incompatibility of common protein solubilizers with mass spectrometry, inefficient protein digestion, and incomplete peptide recovery. Poor peptide recovery is particularly problematic for in-gel protein digestion. Most protein analyses done today rely on protease digestion (i.e., trypsin, chymotrypsin, Lys-C, etc.) to reduce the molecular size of the protein and produce a fingerprint of peptides. Efficient digestion requires that the protein(s) of interest be solubilized and at least partially denatured to allow a protease access to proteolytic sites. To achieve this, additives such as urea, guanidine or SDS are often added prior to digestion. While these adjuncts enhance solubility and/or denaturation, they tend to have a negative impact on MS analysis. Recovery of digested peptides from gel slices represents another problem. Peptide extraction from gel slices relies on diffusion. Because longer peptides diffuse poorly, only relatively short peptides are typically recovered in quantities sufficient for tandem mass spectrometry analysis (MS/MS), decreasing confidence in protein identification (1). Here we present a new reagent, Surfactant, Trypsin Enhancer (a) that helps overcome limitations in protein sample preparation and improve MS results. It can be used to enhance protein solubility, accelerate protease digestion and improve recovery of peptides from polyacrylamide gel slices. Surfactant is a hydrophobic anionic sulfonate (sodium 3-((1-(furan-2-yl)undecyloxy) carbonylamino)propane-1-sulfonate) with a molecular weight of 425.5 Da effectively an SDSlike molecule, but designed to degrade over the course of a digestion reaction. Degradation of the surfactant produces a hydrophilic zwitterionic species (M.W. = 139.2 Da) and a neutral hydrophobic species (M.W. = 238.4 Da), which do not interfere with MS analysis when the surfactant is used in recommended amounts. IN-GEL PROTEIN DIGESTION Figure 1 illustrates the advantages of using Surfactant for in-gel digestions, including significant time savings and improved extraction of long peptides. 3

Standard protocol trypsin protein Surfactant-assisted protocol Surfactant protein Surfactant improves digestion by making the protein more accessible to trypsin. Overnight digestion Extracted peptides Long peptides are generally trapped in gel due to poor diffusion. Extracted peptides Three-hour digestion Degraded Surfactant Surfactant helps to extract long peptides. It degrades by the end of the digestion period. Figure 1. Advantages of in-gel protein digestion with Surfactant,Trypsin Enhancer: significant time savings and improved extraction of long peptides. Figure 2 presents data from an experiment in which we resolved 20 µg of the membrane protein extract from mouse heart (Sigma) in a 1-D SDS polyacrylamide gel. The gel was stained with Coomassie Brilliant Blue R-250. Five bands containing proteins with apparent molecular masses ranging from 52 to 114 kda were excised from the gel and digested with trypsin using either a standard in-gel protocol (2) with overnight digestion, or a Surfactant-assisted protocol with a 3-hour digestion. For the Surfactantassisted protocol, the digestion was performed in the presence of 0.025% Surfactant. Acetonitrile was omitted from the peptide extraction step (3). We found no decrease in peptide yield using Surfactant in place of acetonitrile. The modified extraction step saves 1 2 hours. 7514MA Figure 2 shows the mass spectra of the digested proteins from the isolated protein band having an apparent mass of 55 kda. A significant improvement in the number and magnitude of peptides is evident in the sample prepared with Surfactant compared to the standard method (compare Figure 2, Panels A and B). The most prominent difference between the standard protocol and the Surfactant-assisted protocol is observed in the peptide range of 2,500 4,000 Da. While this mass range is peptide-free in the sample prepared with the standard protocol (Figure 2, Panel A), it contains prominent peptide peaks in the sample prepared with Surfactant (Figure 2, Panel B). The insert in Panel B shows that these long peptides were extracted in quantities sufficient for MS/MS analysis. The quality of MS/MS analysis was high enough to provide identification of 50% of the amino acid residues in the analyzed peptide (Figure 2, Panel C). We used MASCOT, a powerful search engine that uses MS data to identify proteins from a primary sequence database, and identified the major 55 kda protein band as a beta subunit of ATP synthase from H + transporting mitochondrial F1 complex (MASCOT search results are not shown; 4). Sequence coverage of the protein increased 31% (from 45% to 76%), and MASCOT score increased 526 points in the sample prepared with Surfactant. Similar increases in protein coverage and MASCOT score were observed for proteins identified from the other four protein bands (data not shown). Improvement in protein coverage and MASCOT score varied for different proteins in this and additional experiments with maximum increase of up to 1.8- and 6.9-fold for protein coverage and MASCOT score, respectively. Surfactant has been used for in-gel digestion of 34 different cytoplasmic and membrane proteins. Approximately 75% of these proteins yielded 2,500 4,000 Da peptides in amounts sufficient for MS/MS analysis. By expanding MS/MS analysis into the 2,500 4,000 Da peptide range, Surfactant can improve significantly the sequence coverage and confidence of protein identification. Benefits of Surfactant for in-gel digestion are not limited to improved peptide recovery. The surfactant also appears to solubilize and unfold proteins that have precipitated in the gel during fixation (Figure 1). As a result we were able to achieve efficient protein digestion within 3 hours. This saves a substantial amount of time compared to standard overnight incubation. Another likely mechanism by which Surfactant enhances digestion is trypsin stabilization. We found that trypsin can be substantially adsorbed by the plasticware typically used during in-gel digestion reactions. Loss of trypsin to adsorption reached 50% or higher in our tests (data not shown). Surfactant minimizes trypsin adsorption to plastic surfaces. 4 NUMBER 99 MAY 2008 WWW.PROMEGA.COM

A. B. MS/MS, m/z 3350.7292 C. GFQQILAGEYDHLPEQAFYMVGPIEEAVAK 7515TA Figure 2. Improved in-gel protein digestion with Surfactant. Membrane protein extract from mouse heart was resolved in 4 20% SDS-PAGE. The gel was stained with Coomassie Blue R-250.A protein band with an apparent mass of 55 kda was excised from the gel, and the protein was digested using a standard protocol without Surfactant overnight (Panel A) or with Surfactant for 3 hours (Panel B). Digestion was performed at 37 C.The peptides were cleaned up with standard 0.6 µl C18 ZipTip pipette tips (Millipore) and analyzed with 4800 MALDI-TOF/TOF mass spectrometer (Applied Biosystems). Note the substantial increase in number of peptides and peptide signal in the Surfactant-assisted protocol.this led to a substantial increase in sequence coverage and MASCOT score for the identified protein (see the text for more detail).the major improvement was seen with the extraction of long peptides (compare 2,500 4,000 Da range in Panels A and B). Long peptides were extracted in amounts sufficient for MS/MS analysis.the insert shows MS/MS spectrum of one of those long peptides identified only in the surfactant-enhanced sample. Panel C illustrates the annotated sequence for that peptide with its corresponding ions for y and b series highlighted by green dotted lines and red lines, respectively. MS/MS analysis accounted for 50% sequence coverage for this 30 amino acid peptide (the identified residues are highlighted in blue). 5

A. Absorbance (mau) 600 500 400 300 200 100 0 5 10 15 20 25 30 Time (minutes) B. Absorbance (mau) 600 500 400 300 200 100 0 5 10 15 20 25 30 Time (minutes) Figure 3. Surfactant reduces the time required for protein digestion. HPLC chromatograms of myoglobin digests. Myoglobin from horse heart was digested with trypsin (50:1) for 30 minutes at 37 C and resolved on a C18 HPLC column. Panel A. Myoglobin was digested under standard conditions (without Surfactant). The large peak at the right is intact myoglobin. Panel B. Myoglobin was digested in the presence of 0.025% Surfactant. The peaks on the bottom panel indicate the digested peptides. The data show that the protein is digested in the presence of Surfactant within 30 minutes, whereas it remains largely intact under standard conditions. 7258TA Surfactant enhances three major steps in protein MS sample preparation: solubilization, digestion and peptide recovery. Adsorption is also a known cause of peptide loss. Our experiments involving different peptides showed that Surfactant minimizes peptide adsorption to plastic surfaces. We believe preventing peptide adsorption contributes to the higher peptide recovery with Surfactant. IN-SOLUTION PROTEIN DIGESTION Surfactant offers two major benefits for digesting proteins in solution. First, Surfactant efficiently solubilizes proteins. In addition, Surfactant does not interfere with MS analysis when used in the recommended amount. We were able to reproducibly solubilize mouse membrane proteins with Surfactant at room temperature in less than 1 hour. The second advantage of Surfactant for in-solution protein digestion is an enhanced rate of proteolysis. Surfactant can partially or fully denature proteins in an SDS-like manner, providing the protease easier access to cleavage sites. Figure 3 shows that myoglobin from horse heart was fully digested with trypsin in the presence of as little as 0.01% Surfactant in less than 30 minutes. Myoglobin is moderately resistant to proteolysis and, in the absence of denaturing conditions, requires overnight incubation for full digestion. Even complex protein mixtures were efficiently digested in solution in the presence of Surfactant. In our model experiment, 500 µg aliquots of the membrane protein from mouse heart were solubilized under three different conditions: 1) with 0.2% of Surfactant, 2) with 8 M urea, 3) with a mix of 0.2% Surfactant and 8 M urea. After solubilization, reaction volumes were adjusted for digestion. Reactions 1 and 3 were digested with trypsin for 3 hours, and reaction 2 was digested overnight. Each digestion was analyzed separately by offline 2D LC- MS/MS. By using Surfactant we increased the number of total MASCOT protein hits from 477 in urea-assisted digest to 812 hits in all the reactions combined. This is an important achievement because membrane proteins are particularly difficult for MS analysis. We note that Surfactant appears to be the most beneficial as a complementary agent or an additive to urea rather than replacement for it. From 812 proteins, 453 were found in the digestion reaction prepared with Surfactant. The other proteins were found in the reactions prepared with urea or urea/ mix. Certain precautions should be taken when using Surfactant for in-solution digestion. We routinely use a 0.1% solution of Surfactant to solubilize cytoplasmic proteins. To solubilize membrane proteins, we increase the concentration to 0.2%. These higher concentrations of Surfactant are not inhibitory for trypsin, but they can be problematic for peptide recovery as well as for mass spectral acquisition. Therefore, before initiating the protein digestion we recommend diluting Surfactant to 0.03 or 0.05%. 6 NUMBER 99 MAY 2008 WWW.PROMEGA.COM

The Surfactant degradation product generally does not interfere with mass spectral acquisition, however, to improve signal at very low protein or peptide concentrations it may be desirable to remove or reduce the level of degraded surfactant or any other potential contaminant. Solid phase extraction can be used to capture peptides and reduce the amount of degradation product present; however, it is important to avoid micro- C18 (0.2 µl) tips for this purpose and use only the recommended tip sizes for the amount of surfactant used (0.6 µl ZipTip or 10 µl OMIX tips for 50 µl of digest using 0.03% or less Surfactant and 100 µl OMIX tips for more than 50 µl of digest using 0.03% Surfactant). The use of micro-c18 tips will result in a significant decrease in peptide recovery due to competition with degraded surfactant. For more information regarding this issue see reference 3. SUMMARY Surfactant enhances three major steps in protein MS sample preparation: solubilization, digestion and peptide recovery. By increasing the yield of long peptides to quantities sufficient for MS/MS analysis, Surfactant substantially expands the capacity of in-gel protein analysis. Surfactant also enhances digestion of complex protein mixtures in solution, particularly if used concurrently with urea. Surfactant significantly improves protein coverage and overall confidence in protein identification for in-gel and in-solution protein digestion protocols. REFERENCES 1. Wada, Y. et al. (2003) J. Mass. Spec. 38, 117 18. 2. Shevchenko, A. et al. (1996) Proc. Natl. Acad. Sci. USA 93, 14440 5. 3. Surfactant, Trypsin Enhancer Technical Bulletin #TB373 Promega Corporation. 4. Perkins, D.N. et al. (1999) Electrophoresis 20, 3551 67. PROTOCOL Surfactant, Trypsin Enhancer Technical Bulletin, #TB373, Promega Corporation www.promega.com/tbs/tb373/tb373.html ORDERING INFORMATION Product Size Cat.# Surfactant, Trypsin Enhancer 1 mg V2071 5 1 mg V2072 (a) Patent Pending. ProteasMAX is a trademark of Promega Corporation. Coomassie is a registered trademark of Imperial Chemical Industries, Ltd. OMIX is a registered trademark of Varian, Inc. Triton is a registered trademark of Union Carbide Technology Corporation. ZipTip is a registered trademark of Millipore Corporation. 7