Psychosocial Indicators via Hand Tremor

Similar documents
Australian and New Zealand Journal of Psychiatry. Disturbed Sleep in Ecstasy Users reported by Partners/Roommates

Digital Biomarkers in Neurology. Digital Biomarkers Conference March 31, 2016

This copyright in this form is owned by the University of Pittsburgh and may be reprinted without charge only for non-commercial research and

Section Editor Howard I Hurtig, MD

American Board of Psychiatry and Neurology, Inc. Geriatric Psychiatry Core Competencies Outline

A Smartphone-based Wellness Assessment Using Mobile Sensors

PROJECT PERIODIC REPORT

Make a Smart IT & BT Devices for Future Warning for Heart Failure, Hypoglycemia, and Hyperglycemia Smart Watch. LP Lab LP Watch

EVALUATION ON AN ASSISTIVE DEVICE IN SUPPRESSING HAND TREMOR DURING WRITING

Android based Monitoring Human Knee Joint Movement Using Wearable Computing

Collaborating to Develop Digital Biomarkers with Passive Data Collection

A FUTURE IN HEALTHCARE

SmartSensor Home OGTT Kit For Detection Of Diabetes

Speed - Accuracy - Exploration. Pathfinder SL

Session 1: Days 1-3. Session 4: Days Session 2: Days 4-7. Session 5: Days Session 3: Days Day 21: Quit Day!

diasend mobile app for patients

Restoring Communication and Mobility

Bellabeat LEAF Frequently Asked Questions

Sleep Insomnia Severity Index (SISI) Pittsburgh Sleep Quality Inventory. POMS Vigor subscale

A new identity for Scotland s smoking cessation service. Elaine Mitchell Scottish Government

A Profile of Sleeping Habits among College Students-A Cross-sectional Study

Towards Longitudinal Data Analytics in Parkinson s Disease

CESAER Annual Seminar: Biomedical Signal Processing in Vital Sign Analysis: a Key Role for the Implementation of Advanced Technological Tools

PANEL QUESTIONS FOR REGULATORY CONSIDERATION

SPARRA Mental Disorder: Scottish Patients at Risk of Readmission and Admission (to psychiatric hospitals or units)

Evaluation of Interactive Systems. Anthropometry & Anatomy

Keywords Seizure detection, jerking movement detection, epilepsy seizure, Android app, personal health care

Tobacco Free Living Gearing up for the Great American Smoke Out (GASO) 25 October 2012,

Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

Impact of Particle Mass Distribution on the Measurement Accuracy of Low-Cost PM-Sensors

Design of a Device to Help Severely Mentally Ill Patients Quit Smoking

Tremor What is tremor? What causes tremor? What are the characteristics of tremor? What are the different categories of tremor?

What To Expect From A Psychiatrist

BACKGROUND. Paul Taylor. The National Clinical FES Centre Salisbury UK. Reciprocal Inhibition. Sensory Input Boosted by Electrical Stimulation

Blood Glucose Monitoring System. Copyright 2016 Ascensia Diabetes Care Holdings AG diabetes.ascensia.com

Title: Antipsychotic Use in Persons with Dementia CMS ID: ARCO3 NQF #: N/A

Dexcom Current and Future Technology Innovations. Jorge Valdes Chief Technical Officer

Connect to Life. Flyte hearing aids combine natural sound performance with wireless capability, so you can live your life without limitations

JOINT DEVELOPMENT & PRE- TESTING OF AAL SOLUTIONS FOR ELDERLY ÉDER ÁKOS PINKAFELD

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes

KNOWLEDGE VALORIZATION

GUIDELINES FOR SCHOOL PEER GUIDE CO-ORDINATORS

Functional Electrical Stimulation (FES)

itracker Word Count: 1453 Apper Contribution: 352 ECE Creative Applications for Mobile Devices For: Professor Jonathan Rose April 12, 2013

Evaluation of PhonAge: An Adapted Smartphone Interface for Elderly People

AN EVALUATION OF THE NSPCC S SAFE: PERSONAL SAFETY SKILLS FOR DEAF

An Evaluation of an Obstacle Avoidance Force Feedback Joystick

Study on sleep quality and associated psychosocial factors among elderly in a rural population of Kerala, India

INTERNAL Evaluation Activity Summary by the evaluator for project use

Made for Your Smartphone

Predicting About-to-Eat Moments for Just-in-Time Eating Intervention

What Are Your Odds? : An Interactive Web Application to Visualize Health Outcomes

Intelligent Sensor Systems for Healthcare: A Case Study of Pressure Ulcer TITOLO. Prevention and Treatment TESI. Rui (April) Dai

AN INFORMATION VISUALIZATION APPROACH TO CLASSIFICATION AND ASSESSMENT OF DIABETES RISK IN PRIMARY CARE

An important aspect of assessment instruments is their stability across time, often called

AI BASED EXPERT SYSTEM TO AID PATIENTS WITH DEPRESSION DISORDER

Characterization of 3D Gestural Data on Sign Language by Extraction of Joint Kinematics

Design Principles. from Don Norman s Design of Everyday Things and Preece, Rogers and Sharp s Beyond Interaction Design

FAQs for HCP segment New Instructions for Dexcom G5 Mobile Continuous Glucose Monitoring (CGM) System Non-Adjunctive Indication

Draft Examples Document

Use of a mobile application to raise diabetes risk awareness: Reaching the Chinese population

Mental Health and Children with Additional Needs. Amanda Pryde-Jarman Highly Specialist Speech and Language Therapist

Leadership Self, others, thought. Karen Brosnan

Designing a mobile phone-based music playing application for children with autism

Predicting Sleep Using Consumer Wearable Sensing Devices

New Technologies and Analytic Techniques for Dietary Assessment

C/S/E/L :2008. On Analytical Rigor A Study of How Professional Intelligence Analysts Assess Rigor. innovations at the intersection of people,

confidently live life with ease Management Presentation

Challenges in Developing Learning Algorithms to Personalize mhealth Treatments

W3C Semantic Sensor Networks Ontologies, Applications, and Future Directions

Evaluation of Tape Construction on Wear Time for Various Tapes on Human Volunteers: 15-day Study

ON DEVELOPING A REAL-TIME FALL DETECTING AND PROTECTING SYSTEM USING MOBILE DEVICE

Healthy London Partnership

Enabling breakthroughs in Parkinson s disease with wearable technologies and big data analytics

The Stolen Years Mental Health and Smoking Action Report 22 April Emily James, Policy and Campaigns Officer

FES Standing: The Effect of Arm Support on Stability and Fatigue During Sit-to-Stand Manoeuvres in SCI Individuals

APNA 26th Annual Conference Session 1012: November 7, 2012

OPNAVINST G 30 Dec 05

Care that makes sense Designing assistive personalized healthcare with ubiquitous sensing

Web-Based Home Sleep Testing

MORE SOUND THAN EVER

The Relationships between Sleep-Wake Cycle and Academic Performance in Medical Students

Expert System-Based Post-Stroke Robotic Rehabilitation for Hemiparetic Arm

The Impact of Tele-Rehabilitation System on. in Community settings

FitFormula. Sam Liu (Apper) Simran Fitzgerald (Programmer) Jonathan Tomkun (Programmer) ECE1778 Final report

Wearables & Other Emerging Technologies for Sleep Tracking. Anita Valanju Shelgikar, MD October 14, 2017

4.0 Product Testing. 4.1 Routine Testing

The Community Assessment of Risk and Treatment Strategies (CARTS) Project. Professor D. William Molloy COLLAGE University College Cork, Ireland.

Opioid Addiction and an approach to solving the problem. A White Paper by Tom Bronack

Automated mobile systems for multidimensional. feedback

STEP Research. The lived experience of Parkinson's disease: Insights from people living with the condition and those who support them

Continuous Glucose Monitoring

Mind You. Team. Problem and Solution Overview. Becky Leslie Christine Ta Daniel Houtsma Forrest Sun

CALIPSO Project. an innovative approach to insulin therapy management

My Experience. History. Challenge. In Situ ( in place ) Goal Today ESM. Jon Froehlich CSE490f, October 17, Naturalistic data collection is

Demo Mode. Once you have taken the time to navigate your RPM 2 app in "Demo mode" you should be ready to pair, connect, and try your inserts.

Update on the Scottish Health Survey

Vital Responder: Real-time Health Monitoring of First- Responders

Increasing Motor Learning During Hand Rehabilitation Exercises Through the Use of Adaptive Games: A Pilot Study

Transcription:

Carnegie Mellon University From the SelectedWorks of Ted Selker Summer September 5, 2011 Psychosocial Indicators via Hand Tremor Ted Selker, PhD, Carnegie Mellon University Patricia Collins, PhD, Carnegie Mellon University Will Dayton Available at: https://works.bepress.com/ted_selker/7/

Psychosocial Indicators via Hand Tremor Ted Selker, Patricia Collins, Will Dayton Carnegie Mellon University Silicon Valley, Moffett Field, CA 94035 {ted.selker, patricia.collins}@sv.cmu.edu, wdayton@gmail.com Similar to Interact 2011 Poster Carnegie Mellon Silicon Valley Report # 06/2011/001 Abstract. We propose hand tremor as a new type of input that can corroborate psychosocial conditions. An Android application was able to distinguish tremor variability differences between people with and without diagnosed hand tremor. Tremor measurements also corroborated self-assessment of sleep quality. Hand tremor evaluation may be a monitorable, implicit input to systems that respond to various psychosocial states. We encourage researchers to consider how interface design changes when using implicit sensors such as tremor sensing. Keywords: psychosocial indicators, novel user interface, hand tremor, implicit input. 1 Introduction Tremor, an involuntary, semi-periodic movement, is the most common movement disorder [4]. Most people exhibit physiologic hand tremor, a benign, low-amplitude variation in neuromuscular state [5]. Tremor may be heightened by many factors such as strong emotion, physical exhaustion, hypoglycemia, hyperthyroidism, stimulants, alcohol intake or withdrawal, or fever [1]. Other factors such as sleep [2] and smoking [7] have been shown to affect tremor significantly. With a growing number of smartphones sold annually [3], accelerometers provide an omnipresent opportunity to measure the state of hand tremor. Previous efforts to measure tremor to improve cellphone user interfaces have been unsuccessful. Quek, for example was not able to measure body tremor reliably to recognize when a phone was being held [8]. Other attempts at improving the user s experience by reducing the impact of tremor have had limited success [4]. The presented research demonstrates that even if tremor status might not completely indicate the user s condition, it might be part of sensor and contextual information fusion that reveals psychosocial state. The system could then provide context-specific guidance or feedback to the user. 2 Method Most hand tremor is in the 3-6 Hz range, although certain types can reach 12 Hz [6]. We developed an application that detects tremor up to 19 HZ the HTC G1 phone, running Android 1.6. The mobile phone application records 3-D accelerometer while

the subject holds the phone with an unsupported arm for 30 seconds. The number of amplitude maximums; tremor frequency; amplitude average, minimum, and maximum; period average, minimum, maximum; and standard deviation of period are stored on a micro SD card. A pilot study included volunteers with and without tremor disorder. For each measurement, the phone s display first instructs a user to hold the phone comfortably in your dominant hand with the screen facing you. As long as you comfortably can, extend your arm fully while keeping it perpendicular to your body. Remain as still as possible for the duration of the test. A formal study was conducted (age 65) at a senior center. Subjects filled out a pretest survey of experience with hand tremor, took tremor measurements, and filled out the Pittsburgh Sleep Quality Index (PSQI) [9]. Subjects were given the option to have the experimenter read the sleep survey aloud and to record their responses. 3 Results The pilot study included one subject with diagnosed tremor used the application for a few days. Several times each day this subject took a measurement, noting no tremor (N=8 times), slight tremor (N=4 times), or clearly visible tremor (N=7 times). Analysis easily distinguished between the three reported states ( figure 1 and 2). Fig. 1. Mean amplitude maximum (m/s 2 ) Fig. 2. Mean Tremor Frequency (Hz) Unlike amplitude, frequency clearly distinguished the subject with known tremor. None of the non-tremor pilot subjects recorded above 5 Hz, lower than the tremor subject s mean no visible tremor. Most subjects hand movement was in the 3-4 Hz range. Standard deviation of period also proved to distinguish between- and withinsubject comparisons (figure 3). No other pilot subject recorded a standard deviation as low as the tremor subject s.

Fig. 3. Mean standard deviation tremor time period (milliseconds). The pretest survey and data collection protocol were administered to 19 formal study subjects interacting with a phone as a tremor sensor. Sixteen completed the PSQI sleep survey as well. Five reported a history of hand tremor disorder. As in the pilot experiment, amplitude profiles did not distinguish between tremor and no-tremor subjects (Table 1). However, the two groups on frequency measurements yields a t- score of 5.06 for one degree of freedom with less than 0.1 of the result occurring by chance. Comparing the two groups on mean period standard deviation yields a t- score of 3.70, less than 0.1 that the result occurred by chance. As with pilot results, the formal study results suggest that those with hand tremor have higher frequency of tremor and lower standard deviation. The sleep index graph (figure 4) shows a nearly linear correlation with hand tremor frequency. A correlation analysis of PSQI scores and tremor frequency yields an r-score of 0.557 with a probability of less than 0.05 that the result occurred by chance. Table 1. Tremor amplitude and frequency between diagnosed tremor and no tremor groups No History of History of Hand Hand Tremor N= 14 Tremor: N= 5 Mean Amplitude Maximum (m/s 2 ) 10.28 10.30 Mean Frequency (Hz): t-score 5.06 3.52 4.95 Mean Period Standard Deviation (ms): t-score 3.70 138.29 77.11 Fig. 4. Scatter plot of PSQI Scores (x-axis) and hand tremor frequency (y-axis). 4 Discussion Smartphone measurements of tremor frequency corroborated self-report of sleep quality and tremor. The use of such an application to address the healthcare needs of those with tremor appears feasible. We report on overcoming earlier reported obstacles to using tremor to recognize tremor presence [8] and go on to distinguish diagnosed tremor and sleep quality in tremor period and standard deviation. We examined the single factor of sleep quality and found a positive correlation between the PSQI and hand tremor. Tremor is also associated with smoking, caffeine use, physiological and emotional stress--all factors that could be examined to allow users to gain a better understanding of their health.

Our frequency domain instrument consistently distinguished tremor in subjects ranging from their 20s into their 80s. This instrument supports comparisons across people without calibration. This work only begins the story of what might be done with indirect indicators like hand tremor. 5 Conclusion and Future Work The frequency-domain smartphone instrument could simplify neurological diagnosis and give more accurate and responsive ways of prescribing and adjusting medication. Further study should examine fidelity of the measurements and how to present data for decision-making and feedback. Tremor may be heightened by many factors. The specific factor (e.g., hypoglycemia) and the tremor state could be used to provide timely information or guidance to the user (e.g., early warning of a hypoglycemic state). Tremor is the kind of subtle input that can take user experience forward into the psychosocial realms of personal experience and interpersonal exchanges. Tremor is an example of a new kind of input that can add to or corroborate other sensory inputs and might be used in reflective- as well as directive-style interfaces. References 1. Tremor Fact Sheet. National Institute of Neurological Disorders and Stroke, National Institutes of Health, http://www.ninds.nih.gov/disorders/tremor/detail_tremor.htm 2. The Causes and Effects of Lack of Sleep, Sleep Deprivation. Sleep-Deprivation.com. 2 June 2010, http://www.sleep-deprivation.com/articles/types-of-sleep-disorder/lack-ofsleep/index.php 3. Park, W.: Apple Boosts Global Smartphone Market Share Big-Time, Holds on to No. 3 Position. Into Mobile. 7 May 2010. http://www.intomobile. com/2010/05/07/appleboosts-global-smartphone-market-share-big-time-holds-on-to-no-3-position.html 4. Smaga, S.: Tremor. American Family Physician. 68(8):1545-1552. (Oct. 15,2003) 5. Strachan, S. & Murray-Smith R.: Muscle tremor as an input mechanism. (In UIST 2004) 6. Zesiewicz TA, Hauser, RA.: Phenomenology and treatment of tremor disorders. Neurol Clin. 2001; 19:651 80.vii 7. Maykoski, K.A., Rubin, M.B. & Day, A.C.: (197). Effect of Cigarette Smoking on Postural Muscle Tremor. Nursing Research, 12, 39-43 8. Quek, M.: Background sensing using a mobile device. Diss, University of Glasgow. (2008) 9. Buysse, D.J., Reynolds, CF., Monk TH., et al: Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res 28:193 213, (1989a)