IMMUNOLOGY. Source, Isolate, Culture, And Analyze Immune Cells. Scientists Helping Scientists

Similar documents
Fast and Easy Isolation of T Cells

Human Primary Cells It All Starts with the Right Cells

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

Start your T cell research right

In vitro human regulatory T cell expansion

In vitro human regulatory T cell expansion

Human CD4+T Cell Care Manual

Primary Adult Naïve CD4+ CD45RA+ Cells. Prepared by: David Randolph at University of Alabama, Birmingham

MagniSort Human CD4 Memory T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Application Information Bulletin: Human NK Cells Phenotypic characterizing of human Natural Killer (NK) cell populations in peripheral blood

For research or further manufacturing use only. Not for injection or diagnostic procedures.

ISCT Workshop #7 Perspectives in Cell Selection Immunomagnetic Selection

DURACLONE IF BE CERTAIN ABOUT THE RESPONSE. l res. a il n c n. For Research Use Only - Not for use in Diagnostic procedures

BD Flow Cytometry Reagents Multicolor Panels Designed for Optimal Resolution with the BD LSRFortessa X-20 Cell Analyzer

MagniSort Mouse CD4 Naive T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

DISCOVERING ATCC IMMUNOLOGICAL CELLS - MODEL SYSTEMS TO STUDY THE IMMUNE AND CARDIOVASCULAR SYSTEMS

In vitro human regulatory T cell suppression assay

DURACLONE RE THERE ARE EVENTS YOU CANNOT AFFORD TO MISS

Rapid antigen-specific T cell enrichment (Rapid ARTE)

90 min 18 min. 45 min. 14 d

MagniSort Mouse CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Human CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Direct ex vivo characterization of human antigen-specific CD154 + CD4 + T cells Rapid antigen-reactive T cell enrichment (Rapid ARTE)

a Beckman Coulter Life Sciences: White Paper

Human Umbilical Cord Blood CD34 + /133+ Progenitor Cell Care Manual

Fluorochrome Panel 1 Panel 2 Panel 3 Panel 4 Panel 5 CTLA-4 CTLA-4 CD15 CD3 FITC. Bio) PD-1 (MIH4, BD) ICOS (C398.4A, Biolegend) PD-L1 (MIH1, BD)

Supplemental Figure 1. IL-3 blockade with Fab CSL362 depletes plasmacytoid dendritic cells (pdcs), but not basophils, at higher doses.

Automated and Standardized Counting of Mouse Bone Marrow CFU Assays

BD IMag Cell Separation System

CHAPTER 3 LABORATORY PROCEDURES

Healthy cells in = good data out

Generation of monocytederived Dendritic Cells (modcs)

DuraClone IM. Standardized phenotyping panels for studies of the human immune system

Mouse C-Peptide ELISA Kit

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents

SUPPLEMENTARY INFORMATION

MACSxpress Technology Untouched cell isolation directly from blood products

Cover Page. The handle holds various files of this Leiden University dissertation.

Mouse Hepatic Progenitor Organoid Culture: Supplementary Protocols

ab Mammalian Cell Lysis Buffer 5X

sequences of a styx mutant reveals a T to A transversion in the donor splice site of intron 5

91154 PRIME-XV T Cell CDM Liquid 1 L Additional package sizes are available at request

MHC Tetramers and Monomers for Immuno-Oncology and Autoimmunity Drug Discovery

VUmc Basispresentatie

PRIME-XV Dendritic Cell Maturation CDM

SUPPORTING INFORMATIONS

T H 1, T H 2 and T H 17 polarization of naïve CD4 + mouse T cells

Human Innate Lymphoid Cells: crosstalk with CD4 + regulatory T cells and role in Type 1 Diabetes

Optimizing Intracellular Flow Cytometry:

CLINICAL USE OF CELLULAR SUBPOPULATION ANALYSIS IN BM

Supplementary Figure 1. Characterization of basophils after reconstitution of SCID mice

10/18/2012. A primer in HLA: The who, what, how and why. What?

Comprehensive evaluation of human immune system reconstitution in NSG. and NSG -SGM3 mouse models toward the development of a novel ONCO-HU

Melanoma Bridge Meeting

Optimizing Intracellular Flow Cytometry:

Pearson r = P (one-tailed) = n = 9

Supporting Information

MHC MULTIMER PROFICIENCY PANEL 2017

Automatic buffy coat extraction: methodology, feasibility, optimization and validation study

Allergy. pp. 4 5 pp. 6 7 pp BAT Allergens Antibodies

Page 1 of 2. Product Information Contents: ezkine Th1 Activation 2 Whole Blood Intracellular Cytokine Kit

Eosinophil Purification from Peripheral Blood

Pluricyte Cardiomyocytes. using the Multiwell MEA System from Multi Channel Systems

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81)

Human HIV (1+2) antigen&antibody ELISA Kit

Ex vivo Human Antigen-specific T Cell Proliferation and Degranulation Willemijn Hobo 1, Wieger Norde 1 and Harry Dolstra 2*

Supplementary Figure 1. Efficient DC depletion in CD11c.DOG transgenic mice

Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay

Online supplement. Phenotypic, functional and plasticity features of classical and alternatively activated

Detailed step-by-step operating procedures for NK cell and CTL degranulation assays

ExiPrep TM Viral DNA/ RNA Kit

Hematopoiesis. Hematopoiesis. Hematopoiesis

PRODUCT INFORMATION & MANUAL

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

DISCOVER MORE WITH LESS SAMPLE. nanostring.com/3d

Commercially available HLA Class II tetramers (Beckman Coulter) conjugated to

FLOW CYTOMETRY PRINCIPLES AND PRACTICE. Toby Eyre Consultant Haematologist Oxford University Hospitals NHS Foundation Trust June 2018

Children's Hospital of Pittsburgh Annual Progress Report: 2011 Formula Grant

CANCER RESEARCH PRODUCTS. Scientists Helping Scientists

Welcome. Welcome. Emerging Technologies in Flow Cytometry

Procine sphingomyelin ELISA Kit

FinTest IgG4 Screen 20 ELISA KIT

Eosinophils are required. for the maintenance of plasma cells in the bone marrow

For purification of viral DNA and RNA from a wide range of sample materials

Natural Killer Cells: Development, Diversity, and Applications to Human Disease Dr. Michael A. Caligiuri

Blocking antibodies and peptides. Rat anti-mouse PD-1 (29F.1A12, rat IgG2a, k), PD-

CELLULAR THERAPY QUIZ. Correct answers and rationale

Mouse HBsAg(Hepatitis B Virus Surface Antigen) ELISA Kit

D CD8 T cell number (x10 6 )

RODENT Hepatocytes Care Manual

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

Christopher P. Corkum 1, Danielle P. Ings 1, Christopher Burgess 2, Sylwia Karwowska 2, Werner Kroll 2,3 and Tomasz I. Michalak 1*

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit

The spectrum of flow cytometry of the bone marrow

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Transcription:

IMMUNOLOGY Source, Isolate, Culture, And Analyze Immune Cells Scientists Helping Scientists WWW.STEMCELL.COM

TABLE OF CONTENTS Tools For Your Immunology Research 4 Primary Cells: It All Starts with The Right Cells 5 Cell Isolation: Highly Purified Cells for Any Downstream Application 6 EasySep : Fast and Easy Immunomagnetic Cell Isolation 7 EasySep for Mouse Cells 8 EasySep for Human Cells 1 RoboSep : Fully Automated Immunomagnetic Cell Isolation 12 SepMate : Hassle-Free Isolation 13 RosetteSep : Unique Immunodensity Cell Isolation 14 Specialized Media and Supplements 15 High-Quality, Reliable Antibodies Product Listing 16 Human Primary Cells 18 Human Cell Isolation Products 18 T Cells & Subsets 22 B Cells & Subsets 23 NK Cells 24 Other Lymphocytes & Subsets 25 Dendritic Cells 25 Monocytes 25 Granulocytes & Subsets 26 Myeloid Cells 27 Hematopoietic Progenitors 28 Other Cell Types 29 Human Cell Depletion Products 3 Mouse Cell Isolation Products 3 T Cells & Subsets 31 B Cells & Subsets 31 NK Cells 31 Other Lymphocytes & Subsets 32 Dendritic Cells 32 Monocytes 32 Neutrophils 33 Myeloid Cells 33 Hematopoietic Progenitors 34 Other Cell Types 35 Other Species Cell Isolation Products 36 Cell Isolation Magnets and Accessories 37 Instruments 38 Specialized Cell Culture Media, Supplements and Cryopresevation Media 39 Cytokines and ELISA Kits

Tools For Your Immunology Research From primary human cells to cell isolation kits, culture media, and antibodies, STEMCELL Technologies provides the tools you need for every step of your immunology research. STEMCELL Products For Every Step of Your Immune Cell-Based Research Sourcing Isolation Activation, Expansion, & Differentiation Analysis Fresh human cells EasySep ImmunoCult Antibodies Cryopreserved human cells RoboSep Cytokines ELISA kits RosetteSep CryoStor SepMate Lymphoprep WWW.STEMCELL.COM 3

IMMUNOLOGY RESEARCH PRODUCTS Primary Cells It All Starts with the Right Cells Sourcing Isolation Activation, Expansion, & Differentiation Analysis Starting with the right primary cells as the foundation for your experiments is the first step towards success in your research. Choose from a wide range of fresh or cryopreserved human primary cells isolated from peripheral blood, cord blood, bone marrow, and mobilized peripheral blood. 1,2 Cryopreserved immune and progenitor cells are isolated from full-size Leuko Paks (leukapheresis preparations) or entire umbilical cords and are ready to use upon receipt. For users requiring fresh unprocessed tissue samples, whole peripheral blood, whole bone marrow, and Leuko Paks are also available. Cells are shipped with a Certificate of Analysis indicating guaranteed Quality Control testing results including cell count, viability, and purity. All human primary cell products are ethically sourced using informed consent forms (ICFs) and protocols approved by either the Food and Drug Administration (FDA) or an Institutional Review Board (IRB), ensuring the protection of personal information and donor anonymity. 3 Why Use STEMCELL's Primary Cells? PHYSIOLOGICAL RELEVANCE. Choose cells that are physiologically representative of cells in vivo. ACCESS. Obtain large lots of cryopreserved cells, including cells that are rare or difficult to isolate, reducing inter-assay variability. CONVENIENCE. Start your experiments according to your schedule, without being restricted by the availability of tissue samples. FLEXIBLE HOLD POLICIES. Reserve large numbers of cryopreserved cells while you test in your specific applications. See pages 16 and 17 for a complete listing of mononuclear cells, isolated subsets, plasma, and unprocessed tissues from normal and diseased donors, or visit www.stemcell.com/primarycells. Figure 1. Fresh Human Peripheral Blood Leuko Pak (Catalog #75) Leuko Pak containing peripheral blood mononuclear cells (s) enriched using the Spectra Optia Apheresis System from a normal donor. Figure 2. Human T Cells Isolated from Leukapheresis (Leuko Pak) Preparations T cells isolated using the EasySep Human T Cell (Catalog #17951), stimulated with ImmunoCult Human CD3/CD28 T Cell Activator (Catalog #1971) and cultured in ImmunoCult -XF T Cell Expansion Medium (Catalog #1981). 1. Certain cryopreserved products are only available in select territories. Please contact Product and Scientific Support (techsupport@stemcell.com) for further information. 2. Fresh products currently available in the United States and Canada (excluding Quebec). Please contact Product and Scientific Support (techsupport@stemcell.com) for further information. 3. Leuko Pak,, and Bone Marrow (LP, WB, and BM) Donor Screening: Donors are screened for HIV (1 & 2), Hepatitis B, and Hepatitis C. Cryopreserved LP, WB, and BM: Products are shipped with negative test results from donor screening that is done within 9 days of collection. Fresh LP, WB, and BM: If the donor has been screened within 9 days of donation the product will be shipped with negative test results from donor screening. If the donor has not been screened within 9 days of collection, a test sample will be taken at the time of donation and the product will be shipped before the screening results are available. In the unlikely event that a test result is positive, the customer will be contacted as soon as possible (usually within 2-4 business days from the time of shipment). Cord Blood (CB) Donor Screening: Testing for HIV-1 and 2, Hepatitis B, and Hepatitis C is performed on a maternal blood sample and/or on a sample of the donated cord blood. Cryopreserved CB: Products are shipped with negative test results from donor screening. 4 STEMCELL Technologies Inc.

Cell Isolation Highly Purified Cells for Any Downstream Application Sourcing Isolation Activation, Expansion, & Differentiation Analysis Ensure your isolated cells are viable and suitable for downstream functional and biological studies using STEMCELL Technologies fast, easy, and column-free cell separation technologies. Isolate highly purified cells from virtually any sample source, including peripheral blood mononuculear cells, spleen, whole blood, bone marrow, and leukapheresis (i.e., Leuko Pak) samples. EasySep TM Fast and Easy Immunomagnetic Cell Isolation EasySep isolates cells quickly and easily without the use of columns in as little as 8 minutes. With a simple pour, isolated cells are immediately ready for downstream use. RoboSep TM Fully Automated Immunomagnetic Cell Isolation RoboSep -S and RoboSep -16 fully automate all cell labeling and separation steps of the EasySep procedure, minimizing sample handling and freeing up technician time. SepMate TM Hassle-Free Isolation SepMate simplifies mononuclear cell isolation during density gradient centrifugation by eliminating the need to carefully layer samples or pipette off isolated cells. SepMate is suitable for In Vitro Diagnostic (IVD) applications. 1 RosetteSep TM Unique Immunodensity Cell Isolation RosetteSep isolates highly purified cells directly from human whole blood during density gradient centrifugation, reducing your cell isolation workflow to a single step. 1. SepMate IVD is registered as an In Vitro Diagnostic (IVD) device intended for the isolation of mononuclear cells from human whole blood or cord blood by density gradient centrifugation in Canada, the United States, Europe, and Australia. In all other regions, SepMate RUO is available for Research Use Only. WWW.STEMCELL.COM 5

IMMUNOLOGY RESEARCH PRODUCTS EasySep TM Fast and Easy Immunomagnetic Cell Isolation EasySep is a powerful immunomagnetic cell isolation platform that combines the specificity of monoclonal antibodies with the simplicity of a column-free magnetic system for fast and easy isolation of highly purified cell populations that are immediately ready for downstream applications. Cells are targeted for either depletion (negative selection) or selection (positive selection) using antibody complexes directed to specific cell surface antigens. The antibody complexes link targeted cells to magnetic particles. Labeled cells are pulled to the sides of the tube when the sample is placed in an EasySep magnet. Magnetically labeled cells will remain in the tube while the untouched cells can be simply poured or pipetted off into a new tube. Why Use EasySep? FAST AND EASY. Isolate cells from virtually any sample source in as little as 8 minutes without columns or washes. GENTLE. Obtain viable and functional cells that are immediately ready for downstream applications. HIGH PURITY. Achieve up to 99% cell purity with high recovery. VIDEO Fast and Easy Cell Isolation with EasySep www.stemcell.com/easysepvideo EasySep Magnets THE ICONIC COLUMN- FREE CELL ISOLATION PLATFORM FOR LARGER COLUMN- FREE CELL ISOLATIONS FOR VERY LARGE VOLUME CELL ISOLATIONS FOR SIMULTANEOUS OF MULTIPLE SAMPLES FOR SIMULTANEOUS SMALL VOLUME CELL ISOLATIONS EasySep Magnet 1 "The Big Easy" EasySep Magnet 2 Easy 5 EasySep Magnet EasyEights EasySep Magnet EasyPlate EasySep Magnet Catalog # 18 181 182 1813 1812 Number of Samples 1 1 1 8 on each side = 16 total 96 Start Sample Cell Number Range.1-2.5 x 1 8 cells per 5 ml tube.2-1 x 1 8 cells per 14 ml tube.5-2 x 1 8 cells per 5 ml tube.125-2. x 1 8 cells per 5 ml tube.25-8. x 1 8 cells per 14 ml tube.25 -.2 x 1 8 cells per well Collection Method Pour off Pour off Pipette off Pipette off Pipette off 1. Multiple EasySep magnets can be used together with the EasySep Multistand (Catalog #181) for processing up to 4 samples simultaneously or with up to 6 EasySep EasyStands (Catalog #1813) for processing up to 6 samples (see page 36). 2. Multiple The Big Easy EasySep magnets can be used together with the EasySep Multistand (Catalog #181) for processing up to 4 samples simultaneously (see page 36). 6 STEMCELL Technologies Inc.

EasySep for Mouse Cells TM Immunomagnetic Cell Isolation in as Little as 15 Minutes EasySep kits are available for the isolation of mouse cells in as little as 15 minutes from a variety of sample sources, including spleen, bone marrow, lymph nodes, and whole blood. Our EasySep negative selection kits use biotinylated antibodies to target unwanted cells, while positive selection kits use an antibody complex to select cells of interest. Typical EasySep Mouse Cell Isolation Protocol (Negative Selection) 1 2 Add EasySep Isolation Cocktail to single-cell suspension. 4 3 Add EasySep RapidSpheres to cell suspension. Place tube in EasySep Magnet and incubate for 2.5 minutes*. Pour off desired fraction into a new tube. 3 Incubate 1 minutes* Incubate 2.5 minutes* 4 Pipette off desired fractions into new tubes. Place tubes in EasyEights EasySep Magnet and incubate for 5 minutes*. *Times are typical for next-generation negative selection kits. Time for each kit will vary depending on the exact isolation protocol and magnet used. CD4 FITC CD4 FITC Start Isolated CD11c PE Isolated CD11c PE Start MHC II FITC MHC II FITC Figure 3. EasySep Mouse CD4+ T Cell (Catalog #19852) Figure 4. EasySep Mouse CD11c Positive Selection Kit II (Catalog #1878) Starting with mouse splenocytes, the CD4+ T cell content of the isolated fraction typically ranges from 89-96% (gated on viable singlet cells). In the example above, the purities of the start and isolated fractions are 24.6% and 95.7%, respectively. Starting with mouse splenocytes, the CD11c+ cell content of the isolated fraction typically ranges from 86.8 ± 9.7% (gated on viable singlet cells). In the example above, the purities of the start and isolated fractions are 5.7% and 92.3%, respectively. WWW.STEMCELL.COM 7

IMMUNOLOGY RESEARCH PRODUCTS EasySep TM for Human Cells Immunomagnetic Cell Isolation in as Little as 8 Minutes EasySep kits are available for the isolation of human cells from a variety of sample sources, including peripheral blood mononuclear cells (s), whole blood, leukapheresis (i.e., Leuko Pak) samples, bone marrow, and cord blood. Cells of interest are targeted with antibody complexes and magnetic particles for negative or positive selection. Isolate highly purified, untouched, functional human immune cells in as little as 8 minutes with our next-generation EasySep cell isolation kits. Did You Know? There are more cell isolation options than ever with EasySep. EASYSEP DIRECT. Isolate cells straight from whole blood without the need for lysis or centrifugation. EASYSEP RELEASE. Isolate unique and rare cell types by quickly and easily removing magnetic particles from positively selected cells. Typical EasySep Human Cell Isolation Protocol (Negative Selection) 1 2 3 4 Add EasySep Isolation Cocktail to single-cell suspension. Add EasySep RapidSpheres to cell suspension. Place tube in EasySep Magnet and incubate for 3 minutes*. Pour off desired fraction into a new tube. Incubate 5 minutes* Incubate minutes* *Times are typical for next-generation negative selection kits. Time for each kit will vary depending on the exact isolation protocol and magnet used. No particle incubation step is required for next-generation negative selection protocols. Start Isolated Start Isolated START START ISOLATED ISOLATED 13.9 13.9 95.7 95.7 CD4 APC CD4 APC Count (x1) Count (x1) Count (x1) Count (x1) CD3 PerCP-Cy5.5 CD3 PerCP-Cy5.5 CD138 BV421 1 1 1 1 1 1 1 2 1 1 2 3 1 3 1 4 1 4 CD138 CD138 PE PE CD138 BV421 1 1 1 1 1 1 1 2 1 2 1 3 1 3 1 4 1 4 CD138 CD138 PE PE Figure 5. EasySep Human CD4 + T Cell (Catalog #17952) Starting with human peripheral blood mononuclear cells, the CD4 + T cell (CD3 + CD4 + ) content of the isolated fraction is typically 94.8 ± 2.3% (mean ± SD; gated on viable singlet cells). In the example above, the purities of the start and isolated fractions are 39.4% and 98.2%, respectively. Figure 6. EasySep Human and Bone Marrow CD138 Positive Selection Kit II (Catalog #17887) Starting with fresh whole blood spiked with a multiple myeloma cell line, U266, the CD138+ cell content of the selected fraction typically ranges from 83.7-98.3%. In the above example, the purities of the start and final isolated fractions are 9.1% and 9.4%, respectively. 8 STEMCELL Technologies Inc.

Viable and Functional Cells for Your Immunology Research A 8 CD25 Expression (Day ) B 8 CD25 Expression (Day 3) No Stimulation Anti-CD3/CD28 1 Start % CD25+ cells 6 4 2 % CD25+ cells 6 4 2 % 7AAD - CD45 + 75 5 25 Pan-T Cells CD4+ T Cells NK Cells Monocytes Neutrophils Negative Selection Positive Selection C % CD69+ cells CD3 (Pos Sel) Pan-T Cell (Neg Sel) CD69 Expression (Day ) 8 6 4 1 5 CD3 (Pos Sel) Pan-T Cell (Neg Sel) D % CD69+ cells CD3 (Pos Sel) CD69 Expression (Day 3) 8 No Stimulation Anti-CD3/CD28 6 4 2 CD3 (Pos Sel) Pan-T Cell (Neg Sel) Pan-T Cell (Neg Sel) Figure 7. Immune Cells Isolated Using EasySep Technology Are Highly Viable Immune cells were isolated from processed leukapheresis or peripheral blood samples using EasySep positive selection or negative selection kits. Pre- and post-isolation samples were stained with the cell viability dye 7-AAD and appropriate cell surface markers. Cells isolated using EasySep show no significant decrease in viability compared to the starting samples. Data shown as mean ± SEM. Start Figure 8. Human T cells Isolated Using EasySep Show Appropriate Activation Status T cells isolated from s using EasySep positive selection ("Pos Sel") or negative selection ("Neg Sel") kits were assessed for CD25 and CD69 expression immediately after isolation (Day ) and after 3 days in culture with or without CD3/CD28 stimulation. (A,C) At Day, isolated T cells express similar levels of CD25 and CD69 compared to unmanipulated CD3 + s. (B,D) At Day 3, cells remain unactivated in the absence of stimulation, and upregulate activation markers CD25 and CD69 when stimulated. Data shown as mean ± SEM. Figure 9. Human Monocytes Isolated Using EasySep Differentiate and Mature Appropriately upon Stimulation -1 1 1 2 1 3 1 4 1 5-1 1 1 2 1 3 1 4 1 5-1 2 1 1 1 3 1 4 1 5 Day 7 immature DC -1 2 1 1 2 1 3 1 4 1 5 1 1 2 1 3 1 4 1 5 1 1 1 2 1 3 1 4 1 5 Day 7 mature DC Human monocytes were isolated using EasySep positive selection or negative selection kits and then cultured and differentiated into mature dendritic cells (DCs). At Day 5, cells were cultured with maturation supplement for 2 days (mature DCs) or without maturation supplement (immature DCs). As a control, on Day 5 a whole leukapheresis sample was plated and adherence selected for 2 hours. Non-adherent cells were washed away and adherent cells were cultured with maturation supplement for 2 days. The expression of CD8, CD83, and CD86 in immature and mature DCs was determined by flow cytometry. At Day 7, cells express the mature DC markers CD8, CD83, and CD86. -1 1 1 2 1 3 1 4 1 5 1 1 2 1 3 1 4 1 5 1 1 1 2 1 3 1 4 1 5 CD8 CD83 CD86 Leukapheresis CD14 Positive Selection Monocyte Negative Selection WWW.STEMCELL.COM 9

IMMUNOLOGY RESEARCH PRODUCTS RoboSep TM Fully Automated Immunomagnetic Cell Isolation RoboSep instruments offer true walk-away automation of immunomagnetic cell separation. Using EasySep reagents, RoboSep -S and RoboSep -16 perform all cell labeling and magnetic isolation steps for up to four and sixteen samples, respectively. Sample handling is minimized and the use of disposable tips in these column-free systems ensures that isolated cells of interest are immediately available for any downstream application. RoboSep TM -S RoboSep TM -16 The compact design of RoboSep -S brings the convenience of automated cell isolation to any busy laboratory. The enhanced liquid-handling capabilities of RoboSep -16 allow high-volume users to efficiently isolate desired cells with speed and confidence. Why Use RoboSep? FULLY AUTOMATED. Just load reagents and samples and walk away. SIMULTANEOUS OR SEQUENTIAL CELL ISOLATION. Perform simultaneous cell isolations for up to 4 samples using RoboSep -S and 16 samples using RoboSep -16, or sequentially isolate different cell types from the same sample. NO CROSS-CONTAMINATION. Cells are handled with single-use disposable tips, never passing through reusable columns or tubing. VERSATILE. Use EasySep technology to isolate virtually any cell type from any species or sample, including whole blood. Programs are cell type-specific and customizable. 1 STEMCELL Technologies Inc.

How RoboSep Works RoboSep -S and RoboSep -16 fit easily into the workflow of any lab that needs the multi-sample processing capacity, speed, reliability, and convenience of automated cell isolation. Start your cell isolation protocol with as little as 5 minutes of hands-on time with RoboSep -S and RoboSep -16. Both pre-programmed routine protocols and customizable protocols are available to meet your unique cell isolation needs. Typical RoboSep -S Protocol 1 Select protocol. Load sample, 2 Press Run. 3 EasySep reagents, buffer, and tips in carousel. Return in 25 to 6 minutes to collect your separated cells. Typical RoboSep -16 Protocol 1 Select protocol. Load sample, 2 Press Run. 3 EasySep reagents, buffer, and tips. Return in 25 to 6 minutes to collect your separated cells. We like the reliability of the RoboSep, the minimization/elimination of specimen handling by the tech during subset separation, and the low maintenance of the instrument. These factors are important to us with such a high throughput of samples processed. PRODUCT TOUR See RoboSep Instruments in Action www.robosep.com Wendy Leong, Senior Clinical Laboratory Scientist PATHOLOGY/STANFORD BLOOD CENTER LABORATORY WWW.STEMCELL.COM 11

4 5 IMMUNOLOGY RESEARCH PRODUCTS SepMate TM Hassle-Free Isolation SepMate is a specialized tube for fast and easy isolation in just 15 minutes. The SepMate tube contains a unique insert that prevents the density gradient medium 1 (e.g., Ficoll-Paque or Lymphoprep ) and blood sample from mixing. The density gradient medium is pipetted through a central hole in the insert, and the sample is poured or rapidly pipetted on top of the insert. This eliminates the need to carefully layer the sample directly onto the density gradient medium, an otherwise time-consuming and highly laborious step. Only 1 minutes of centrifugation are required, and this step can be carried out with the brake on, further reducing the total time necessary for separation. After centrifugation, plasma and s are simply poured into a new tube. SepMate is registered as an In Vitro Diagnostic (IVD) device in select regions. 1,2 Why Use SepMate? EASY. Avoid the need for slow and laborious sample layering over the density gradient medium. FAST. Isolate s directly from whole blood in just 15 minutes. CONSISTENT. Eliminate errors and minimize variability between separations. VERSATILE. Combine with RosetteSep to isolate purified cell subsets from whole blood in 25 minutes. 3 REGISTERED. Use with whole blood or bone marrow samples for In Vitro Diagnostic (IVD) applications. 1 Typical SepMate Protocol 1 Add density gradient medium through SepMate insert. SepMate insert Density gradient medium (e.g. Ficoll-Paque or Lymphoprep ) Products 2 Pipette sample onto insert. SepMate insert PRODUCT NAME SepMate -15 (IVD) 1 85415 SepMate -15 (RUO) 2 86415 SepMate -5 (IVD) 1 8545 SepMate -5 (RUO) 2 8645 BLOOD VOLUME PROCESSED (ML).5-5 4-17 UNIT SIZE 1 tubes 3 Centrifuge for 1 minutes (brake on). PRODUCT NAME DENSITY UNIT SIZE 4 Lymphoprep 7851 1.77 g/ml 5 ml Plasma s Density gradient medium RBCs and granulocytes Pour s 1. SepMate (IVD) is available only in Canada, the United States, Europe, and Australia, where it is registered as an In Vitro Diagnostic (IVD) device for the isolation of mononuclear cells from human whole blood or bone marrow by density gradient centrifugation. 2. SepMate for Research Use Only (RUO) is available in regions where SepMate is not registered as an IVD device. 3. Select RosetteSep products carry the CE mark and are suitable for IVD applications in countries where the CE marking is recognized. Did You Know? Lymphoprep has the same density as Ficoll-Paque, is more cost-effective, and can be substituted for Ficoll-Paque without any need to change your existing protocols. 12 STEMCELL Technologies Inc.

RosetteSep TM Unique Immunodensity Cell Isolation RosetteSep is a fast and easy immunodensity procedure for the isolation of untouched cells directly from whole blood. By crosslinking unwanted cells to red blood cells (RBCs) present in the sample, RosetteSep eliminates the need for a separate magnetic separation step because cells are purified during standard density gradient centrifugation. This approach significantly reduces sample handling time and maximizes convenience. Typical RosetteSep Protocol 1 2 3 4 Add RosetteSep Enrichment Cocktail. Layer over density gradient medium. Centrifuge for 2 minutes*. Collect cells. Incubate 2 minutes Plasma Enriched cells Whole blood Add Lymphoprep Density gradient medium Lymphoprep density gradient medium Red blood cells and unwanted cells (rosetted) Highly purified cells are left untouched *Use SepMate to reduce centrifugation time to 1 minutes with brake on. Start: CD45 + Gate Isolated: CD45 + Gate Cell to enrich Red Blood Cells Rosetted (unwanted) cell Magnification 4X CD3 PerCP-Cy5.5 CD56 PE CD3 PerCP-Cy5.5 CD56 PE Figure 1. Micrograph of a Blood Sample After Addition of the RosetteSep Cocktail, and Prior to Density Gradient Centrifugation Figure 11. RosetteSep Human NK Cell Enrichment Cocktail (Catalog #1525) Starting with whole peripheral blood, the NK cell content (gated on CD45 + cells) of the isolated fraction typically ranges from 8-98%. In the example above, the purities of the start and isolated fractions are 7.2% and 92.4%, respectively. RosetteSep TM and SepMate TM Simplified and Standardized Cell Isolation RosetteSep is easily combined with SepMate to rapidly and reproducibly isolate subsets from whole blood. By using the unique SepMate tube, sample throughput is increased and errors associated with improper sample layering are eliminated. This allows even users with minimal training to consistently perform cell isolation by density gradient centrifugation in a busy laboratory environment. WWW.STEMCELL.COM 13

IMMUNOLOGY RESEARCH PRODUCTS Specialized Media and Supplements For Cell Culture, Activation, Expansion and Differentiation Sourcing Isolation Activation, Expansion, & Differentiation Analysis With high-quality and viable cells as the foundation for your research, integrating STEMCELL Technologies cell culture reagents into your workflow will ensure reliable results. The new ImmunoCult products have been designed to ensure optimal activation, expansion, differentiation, and maintenance of immune cells. These specialized media, activators, and supplements allow you to culture immune cells under defined stimulatory conditions to activate, expand, or differentiate the cell population of interest. For a detailed list of ImmunoCult products, see page 38 or visit www.immunocult.com. ImmunoCult for T Cell Research Advance your basic T cell immunology and clinical T cell engineering research with ImmunoCult T cell activators, expansion medium, and differentiation supplements designed for: Robust human T cell activation and expansion without the use of magnetic beads, feeder cells, or antigens. Consistent human T cell expansion in serum- and xeno-free expansion medium. Differentiation of human and mouse T cells into Th1, Th2, and regulatory T cell subsets. ImmunoCult for Dendritic Cell Research Dendritic cells (DCs) are potent antigen-presenting cells and key regulators of the immune response. These cells are of great interest in vaccine development research for cancer and infectious diseases. Further your immunology research with ImmunoCult -ACF Dendritic Cell Medium and Supplements designed for: Generation of mature DCs from isolated monocytes. Obtaining a high yield of mature DCs with the desired phenotype and function. ImmunoCult for Macrophage Research Macrophages are key players in the immune response due to their role in immune regulation, tissue repair, and tumor biology. Bring consistency to your macrophage research with ImmunoCult -SF Macrophage Medium designed for: Generation of mature macrophages from isolated monocytes in a serum-free culture. Reliable differentiation and activation of M1 or M2a macrophages using optimized protocols. Activate, expand, or differentiate with cytokines, chemokines, and growth factors from STEMCELL Technologies. These highquality reagents ensure reproducibility across a variety of applications for immunology and stem cell research. To learn more about STEMCELL s cytokines, see page 39 or visit www.stemcell.com/cytokines. 14 STEMCELL Technologies Inc.

High-Quality, Reliable Antibodies Take the Guesswork out of Finding the Right Antibody Sourcing Isolation Activation, Expansion, & Differentiation Analysis Using the right antibody is an essential component for your research. Antibodies from different vendors provide variable and potentially sub-optimal staining profiles. STEMCELL Technologies offers a line of high-quality primary and secondary antibodies that have been verified to work with our cell isolation and cell culture reagents in specific applications, ensuring that your downstream cell analysis, including phenotyping and purity assessments, works consistently. New antibodies are added to our growing inventory on a continuing basis, and Pacific Blue conjugates for some of our most popular antibodies are now available. To find staining antibodies compatible with our cell isolation kits, please refer to pages 18-34. For a complete list of available antibodies visit www.stemcell.com/antibodies. Importance of Using a STEMCELL-Verified Antibody Vendor 1 Start Vendor 2 Vendor 3 Isotype Control USING AN ANTIBODY NOT VERIFIED BY STEMCELL CAN LEAD TO INACCURATE RESULTS. Isolated Isotype Control EXAMPLE OF AN ANTIBODY VERIFIED TO WORK WITH OUR CELL ISOLATION KITS. CD24 PE CD4 Alexa Fluor 488 Figure 12. Anti-Mouse CD24 Antibodies (Clone M1/69) from Three Different Vendors Exhibit Varying Staining Profiles Surface expression of CD24 on C57BL/6 mouse bone marrow cells was examined by flow cytometry using anti-mouse CD24, clone M1/69, PE antibody from three different vendors according to their recommended protocols (grey shaded histograms) or Rat IgG2b, kappa PE isotype control antibody (black filled histogram). Vendor 1 corresponds to antibody from STEMCELL Technologies (Catalog #699PE). Figure 13. STEMCELL s Verified Anti-Human CD4, Clone OKT4, Alexa Fluor 488 (Catalog #616AD) Has Been Verified for Purity Assessments of Cells Isolated with EasySep Kits Flow cytometry analysis of human s isolated with the EasySep Human CD4 Positive Selection Kit and labeled with Anti-Human CD4, Clone OKT4, Alexa Fluor 488. Histograms show labeling of the total s (Start) and isolated cells (Isolated). Labeling with a mouse IgG2b, kappa Alexa Fluor 488 isotype control antibody is shown in the bottom panel (open histogram). Why Use STEMCELL's Antibodies? LARGE PORTFOLIO. Large selection of primary and secondary antibodies and isotype controls. COMPATIBLE. Verified to work with our cell isolation and cell culture reagents for select applications. VERSATILE. Proven performance for multiple applications. RELIABLE. Trusted by our dedicated team of research scientists. WWW.STEMCELL.COM 15

IMMUNOLOGY RESEARCH PRODUCTS Product Listing Human Primary Cells Cryopreserved Human Peripheral Blood Products 1 Fresh Human Peripheral Blood Products 3 DESCRIPTION QUANTITY Peripheral Blood Mononuclear Cells 2 CD34 + Cells Pan-T Cells 15 million cells 725.1 25 million cells 725.2 5 million cells 725.3 1 million cells 725.2 million cells 74.5 million cells 74.1 1 million cells 74.2 2 million cells 724 4 million cells 724.1 CD4 + T Cells 15 million cells 726 CD4 + CD25 + T Cells 2 million cells 728 CD4 + CD45RA + T Cells 5 million cells 729 CD4 + CD45RO + T Cells 5 million cells 731 CD8 + T Cells 1 million cells 727 CD8 + CD45RA + T Cells 5 million cells 73 B Cells 1 million cells 723 2 million cells 723.1 CD19 + CD27 - Naïve B Cells 1 million cells 732 CD19 + B Cells 1 million cells 733 Monocytes 1 million cells 734 CD14 + Monocytes 1 million cells 735.1 2 million cells 735.2 4 million cells 735 NK Cells 5 million cells 736 DESCRIPTION ANTICOAGULANT 3 QUANTITY Peripheral Blood Leuko Pak 4 ACDA 5 Whole Peripheral Blood ACDA 5 Quarter Size 75.2 Half Size 75.1 Full Size 75 1 x 1 ml 754.1 2 x 1 ml 754.2 3 x 1 ml 754.3 4 x 1 ml 754.4 5 x 1 ml 754.5 1 x 1 ml 754.6 45 ml 754 CP2D 5 45 ml 751 EDTA 5 Na Heparin 5 1 x 1 ml 758.1 2 x 1 ml 758.2 3 x 1 ml 758.3 4 x 1 ml 758.4 5 x 1 ml 758.5 1 x 1 ml 758.6 1 x 1 ml 757.1 2 x 1 ml 757.2 3 x 1 ml 757.3 4 x 1 ml 757.4 5 x 1 ml 757.5 1 x 1 ml 757.6 CD56 + NK Cells 5 million cells 737 Macrophages 1.5 million cells 742 BDCA4 + Cells.5 million cells 738 Immature Dendritic Cells 1.5 million cells 741 Plasmacytoid Dendritic Cells.5 million cells 746 1 ml 739.1 2 ml 739.2 3 ml 739.3 Plasma 4 ml 739.4 5 ml 739.5 1 ml 739 15 ml 739.6 For a complete listing of primary cells products, including mobilized peripheral blood products and cultured cells, please visit www.stemcell.com/primarycells. 16 STEMCELL Technologies Inc.

Cryopreserved Diseased State Human Peripheral Blood Mononuclear Cell Products 1,6 DESCRIPTION QUANTITY Rheumatoid Arthritis 1 million cells 75 Cryopreserved Human Umbilical Cord Blood Products 1 DESCRIPTION QUANTITY 15 million cells 77.1 Ulcerative Colitis 1 million cells 751 Crohn s Disease 1 million cells 752 COPD 1 million cells 753 Lupus (SLE) 1 million cells 754 Osteoarthritis 1 million cells 755 Psoriasis 1 million cells 756 Asthma 1 million cells 757 Celiac Disease 1 million cells 758 Diabetes, Type I 1 million cells 761 Mononuclear Cells (MNCs) CD34 + Cells (Mixed Donor) CD34 + Cells (Single Donor) 5 million cells 77.2 15 million cells 77.2 million cells 78.1.5 million cells 78.3 1 million cells 78 5 million cells 78.6.2 million cells 78.2.5 million cells 78.4 1 million cells 78.5 Diabetes, Type II 1 million cells 762 Chronic Lymphocytic Leukemia (CLL) 1 million cells 763 CD36 + Cells 1 million cells 79 1 million cells 713 CD19 + B Cells 2.5 million cells 713.1 Cryopreserved Human Bone Marrow Products 1 DESCRIPTION QUANTITY 5 million cells 71.1 15 million cells 71.2 Mononuclear Cells (MNCs) 25 million cells 71 5 million cells 71.3 1 million cells 71.4.1 million cells 72.1.3 million cells 72.2.5 million cells 72.3 CD34 + Cells 1 million cells 72 2 million cells 72.4 5 million cells 72.5 CD36 + Cells 7 1 million cells 73 CD15 + Cells.3 million cells 75 CD33 + Cells 5 million cells 76 Stromal Cells 7.75 million cells 722 Stromal Cells in ACF Medium 7.75 million cells 771 5 million cells 713.2 Pan-T Cells 15 million cells 714 CD4 + T Cells 15 million cells 715 CD4 + CD45RA + T Cells 15 million cells 717 CD8 + T Cells 5 million cells 716 CD14 + Monocytes 5 million cells 718 CD56 + NK Cells 1 million cells 719 Plasma 1 ml 72.1 2 ml 72.2 3 ml 72.3 4 ml 72.4 5 ml 72 1. Certain cryopreserved products are only available in select territories. Please contact Product and Scientific Support (techsupport@stemcell.com) for further information. 2. High-resolution HLA typing and CMV status are available upon request. 3. Fresh products currently available in the United States and Canada (excluding Quebec). Please contact Product and Scientific Support (techsupport@stemcell.com) for further information. 4. A full size Leuko Pak typically contains 1.1 ±.3 x 1 1 cells and has a volume of approximately 12 ml 5. ACDA - Acid Citrate Dextrose Solution A; CP2D - Citrate-Phosphate-Double Dextrose; EDTA - Ethylenediaminetetraacetic Acid; Na Heparin - Sodium Heparin 6. Diseased states indicate s obtained from donors diagnosed with given condition. 7. Cultured Cell Product WWW.STEMCELL.COM 17

IMMUNOLOGY RESEARCH PRODUCTS Human Cell Isolation Products Human T Cell Isolation by Negative Selection Naïve Pan T Cells EasySep Human Naïve Pan T Cell 96.1 ± 2.3% 1 x 1 9 cells CD4 (Catalog #616) CD8a (Catalog #622) CD45RO (Catalog #697) 17961 17961RF EasySep Human T Cell 96.7 ± 1.5% 1 x 1 9 cells EasySep HLA T Cell Enrichment Kit 95. - 99.% 1 x 1 9 cells 17951 17951RF 1951HLA 1951HLARF Spleen, Lymph Node, EasySep Direct HLA Crossmatch T Cell 94.9 ± 1.5% 1 ml 19671 19671RF 89671 3 89671RF 3 T Cells EasySep HLA T Cell Enrichment Kit EasySep Direct Human T Cell 93.1-98.% 2 ml CD2 (Catalog #67) CD4 (Catalog #616) CD8a (Catalog #622) 19951HLA 19951HLARF 95.3 ± 1.4% 1 ml 19661 RosetteSep Human T Cell Enrichment Cocktail 9. - 97.% 4 ml 1521 2 ml 1561 RosetteSep HLA T Cell Enrichment Cocktail 9. - 97.% 25 ml 1561HLA 1 ml 1581HLA RosetteSep HLA Lymphoid Cell Enrichment Kit > 85% 2 ml 15271HLA 4 Human T Cell Isolation by Positive Selection CD2 + Cells EasySep Human CD2 Positive Selection Kit EasySep HLA CD2 Positive Selection Kit 86.3-98.% 86.3-98.% 1 x 1 9 cells CD56 (Catalog #621) 18657 18657RF 18657HLA 18657HLARF CD3 + Cells EasySep Release Human CD3 Positive Selection Kit EasySep Human CD3 Positive Selection Kit II 98.7 ±.9% 99.2 ±.2% 1 x 1 9 cells CD4 (Catalog #616) CD8a (Catalog #622) 17751 17851 17851RF, Buffy Coat EasySep HLA Chimerism Whole Blood CD3 Positive Selection Kit 92.4-99.8% 6 ml CD2 (Catalog #67) CD5 (Catalog #682) CD2 (Catalog #68) 17871 17871RF RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells 2. Purities shown as either a range or mean ± SD. 3. This kit carries the CE mark and is available as a Class I in vitro diagnostic device (IVD) in the European Union, Canada, and Australia. To learn more about the regulatory status of this product in your specific region, contact info@stemcell.com. 4. This kit is designed to enrich only CD3 + lymphoid cells. 18 STEMCELL Technologies Inc.

Human CD4 + T Cell Isolation by Negative Selection CD4 + T Cells EasySep Human CD4 + T Cell EasySep Direct Human CD4 + T Cell RosetteSep Human CD4 + T Cell Enrichment Cocktail 94.8 ± 2.3% 1 x 1 9 cells 17952 17952RF 93.6 ± 2.5% 1 ml 4 ml CD4 (Catalog #616) CD8a (Catalog #622) 19662 1522 94. ± 5.% 2 ml 1562 Human CD4 + T Cell Isolation by Positive Selection CD4 + T Cells EasySep Release Human CD4 Positive Selection Kit EasySep Human CD4 Positive Selection Kit II EasySep Human CD4 Positive Selection Kit 96.1 ± 4.1% 1 x 1 9 cells 9. ± 6.% 1 x 1 9 cells 97.1-99.9% 6 ml CD4 (Catalog #616) CD8a (Catalog #622) 17752 17852 17852RF 1882 1882RF Human CD4 + T Cell Subset Isolation by Negative Selection Resting CD4 + T Cells EasySep Human Resting CD4 + T Cell 89. ± 5.3% 1 x 1 9 cells CD8 (Catalog #622) CD25 (Catalog #6153) 17962 17962RF Naïve CD4 + T Cells Memory CD4 + T Cells EasySep Human Naïve CD4 + T Cell II EasySep Human Memory CD4 + T Cell Enrichment Kit 96.6 ± 1.5% 86. - 98.% 1 x 1 9 cells 1 x 1 9 cells CD4 (Catalog #616) CD45RO (Catalog #697) 17555 17555RF 19157 19157RF Regulatory T Cells Please see page 21. Human CD4 + T Cell Subset Isolation by Positive Selection Th1 Cells EasySep Human Th1 Cell 85. - 95.% 1 x 1 9 cells CD4 (Catalog #616) 18161 18161RF Th17 Cells EasySep Human Th17 Cell Enrichment Kit II 96. - 98.% 2 x 1 9 cells CD4 (Catalog #616) CD196 (Catalog #69) 17862 Central and Effector Memory CD4 + T Cells EasySep Human Central and Effector Memory CD4 + T Cell 92.3 ± 3.9% (CM) 3 92.4 ± 4.1% (EM) 3 1 x 19 cells CD3 (Catalog #6127) CD45RO (Catalog #697) 17865 Regulatory T Cells Please see page 21. RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells 2. Purities shown as either a range or mean ± SD. 3. CM - Central Memory; EM - Effector Memory WWW.STEMCELL.COM 19

IMMUNOLOGY RESEARCH PRODUCTS Human CD8 + T Cell Isolation by Negative Selection EasySep Human CD8 + T Cell 85.6 ± 4.9% 1 x 1 9 cells 17953 17953RF CD8 + T Cells EasySep Direct Human CD8 + T Cell RosetteSep Human CD8 + T Cell Enrichment Cocktail 82.4 ± 4.9% 1 ml 4 ml CD4 (Catalog #616) CD8a (Catalog #622) 19663 1523 84. ± 9.% 2 ml 1563 Human CD8 + T Cell Isolation by Positive Selection CD8 + Cells EasySep Human CD8 Positive Selection Kit II EasySep Human CD8 Positive Selection Kit 96.5 ± 2.4% 1 x 1 9 cells 97.1-99.6% 6 ml CD4 (Catalog #616) CD8a (Catalog #622) 17853 17853RF 1883 1883RF Human CD8 + T Cell Subset Isolation by Negative Selection Naïve CD8 + T Cells EasySep Human Naïve CD8 + T Cell II 93.7 ± 2.4% 1 x 1 9 cells CD8a (Catalog #622) CD45RO (Catalog #697) CD56 (Catalog #621) 17968 17968RF Memory CD8 + T Cells EasySep Human Memory CD8 + T Cell Enrichment Kit 72. - 92.% 1 x 1 9 cells CD8a (Catalog #622) CD45RO (Catalog #697) 19159 19159RF Human CD8 + T Cell Subset Isolation by Positive Selection Central and Effector Memory CD8 + T Cells EasySep Human Central and Effector Memory CD8 + T Cell 86.8 ± 8.4% (CM) 3 88.7 ± 6.5% (EM) 3 1 x 19 cells CD3 (Catalog #6127) CD45RO (Catalog #697) 17869 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells 2. Purities shown as either a range or mean ± SD. 3. CM - Central Memory; EM - Effector Memory 2 STEMCELL Technologies Inc.

Human Regulatory T Cell Isolation by Negative Selection CD4 + CD127 low T Cells CD4 + CD127 low CD49d - T Cells Whole Blood RosetteSep Human CD4 + CD127 low T Cell Enrichment Cocktail EasySep Human CD4 + CD127 low CD49d - Regulatory T Cell Enrichment Kit -- 2 ml 57.4-87.4% 3 2 x 1 9 cells CD4 (Catalog #616) CD25 (Catalog #6153) 15361 19232 19232RF Human Regulatory T Cell Isolation by Positive Selection CD25 + Cells CD4 + CD127 low CD25 high T Cells EasySep Human CD25 Positive Selection and Depletion Kit Human CD4 + CD127 low CD25 + Regulatory T Cell 81-98% 1 x 1 9 cells CD4 (Catalog #616) CD25 (Catalog #6153) 17861 85.3 ± 2.1% 1 x 1 9 cells 1863 Human Gamma/Delta T Cell Isolation by Negative Selection Gamma/Delta T Cells EasySep Human Gamma/Delta T Cell 9. - 97.% 1 x 1 9 cells CD2 (Catalog #67) CD4 (Catalog #616) CD8a (Catalog #622) 19255 19255RF RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells 2. Purities shown as either a range or mean ± SD. 3. Purity data represents the CD3 + CD4 + CD127 low CD25 + FOXP3 + cell content of the enriched fraction. WALLCHART Regulatory T Cells Wallchart www.stemcell.com/tregwallchart SCIENTIFIC POSTER Column-Free Isolation of Human Gamma/Delta T Cells www.stemcell.com/gammadeltatposter WWW.STEMCELL.COM 21

IMMUNOLOGY RESEARCH PRODUCTS Human B Cell and Subset Isolation by Negative Selection EasySep Human B Cell 95.1 ± 1.4% 1 x 1 9 cells CD19 (Catalog #65) 17954 17954RF EasySep HLA B Cell Enrichment Kit 95. - 99.% 1 x 1 9 cells CD19 (Catalog #65) CD2 (Catalog #68) 1954HLA 1954HLARF B Cells 3 Spleen, Lymph Node, EasySep Direct HLA Crossmatch B Cell EasySep HLA B Cell Enrichment: Complete Processing Kit for Whole Blood 97 ± 3% 1 ml 81.5-99.7% 2 ml CD19 (Catalog #65) CD2 (Catalog #68) 19684 19684RF 89684 6 89684RF 6 19954HLA 19954HLARF EasySep Direct Human B Cell RosetteSep Human B Cell Enrichment Cocktail RosetteSep HLA B Cell Enrichment Cocktail 95.3 ± 2.7% 1 ml 19674 4 ml 1524 81. - 83.% 2 ml CD19 (Catalog #65) 1564 25 ml CD2 (Catalog #68) 1564HLA 81. - 83.% 1 ml 1584HLA Pan-B Cells 4 EasySep Human Pan-B Cell Enrichment Kit 9-99% 1 x 1 9 cells CD4 (Catalog #616) CD8a (Catalog #622) CD14 (Catalog #64) CD16 (Catalog #641) CD19 (Catalog #65) CD43 (Catalog #685) CD56 (Catalog #621) 19554 19554RF B Cells (without CD43 depletion) 5 EasySep Human B Cell Enrichment Kit II Without CD43 Depletion EasySep Direct Human B-CLL Cell 84.9-13.9% 1 x 1 9 cells 17963 17963RF CD19 (Catalog #65) CD2 (Catalog #68) 87. ± 7.6% 1 ml 19664 Naïve B Cells EasySep Human Naïve B Cell EasySep Direct Human Naïve B Cell 94.9 ± 2.2% 1 x 1 9 cells 17254 17254RF CD19 (Catalog #65) CD2 (Catalog #68) 91.8 ± 3.6% 1 ml 19264 Plasma Cells Bone Marrow RosetteSep Human Multiple Myeloma Cell Enrichment Cocktail > 95.% 4 ml 15129 CD138 (Syndecan-1) 2 ml (Catalog #63) 15169 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells 2. Purities shown as either a range or mean ± SD. 3. CD43 B cells from normal samples. 4. B cells including plasma cells from non-leukemia or lymphoma samples. 5. B cells from B cell leukemia or lymphoma samples, or other disease states in which B cells may express CD43, CD123, or CD36. Note that samples from normal healthy donors were used to obtain purity data. The purity of isolated cells is typically higher when processing samples that have an elevated frequency of B cells (e.g., CLL samples). 6. This kit carries the CE mark and is available as a Class I in vitro diagnostic device (IVD) in the European Union, Canada, and Australia. To learn more about the regulatory status of this product in your specific region, contact info@stemcell.com. 22 STEMCELL Technologies Inc.

Human B Cell and Subset Isolation by Positive Selection CD19 + Cells EasySep Release Human CD19 Positive Selection Kit EasySep Human CD19 Positive Selection Kit II 97.7 ± 2.3% 1 x 1 9 cells 97. - 99.% 1 x 1 9 cells CD19 (Catalog #65) CD2 (Catalog #68) 17754 17854 17854RF, Buffy Coat EasySep HLA Chimerism Whole Blood CD19 Positive Selection Kit 94.3-99.6% 6 ml 17874 17874RF CD2 + Cells EasySep Human CD2 Positive Selection Kit 95.6-99.8% 6 ml CD19 (Catalog #65) CD22 (Catalog #683) 18685 18685RF CD19 + CD27 + (Memory B) Cells EasySep Human Memory B Cell 97 ± 2% 1 x 1 9 cells CD19 (Catalog #65) CD27 (Catalog #616) 17864 CD138 + (Plasma) Cells, Bone Marrow, Bone Marrow EasySep Human CD138 Positive Selection Kit II EasySep Human and Bone Marrow CD138 Positive Selection Kit II 93. - 98.2% 2 x 1 9 cells 83.7-98.3% 6 ml CD138 (Syndecan-1) (Catalog #63) 17877 17877RF 17887 17887RF Human NK Cell Isolation by Negative Selection EasySep Human NK Cell 85. ± 8.% 1 x 1 9 cells 17955 17955RF NK Cells EasySep Direct Human NK Cell RosetteSep Human NK Cell Enrichment Cocktail 8. - 98.% 1 ml CD56 (Catalog #621) 19665 4 ml 1525 76.8 ± 12.2% 2 ml 1565 Human NK Cell Isolation by Positive Selection CD56 + Cells Buffy Coat EasySep Human CD56 Positive Selection Kit II EasySep HLA Chimerism Buffy Coat CD56 Positive Selection Kit 94. ± 3.% 1 x 1 9 cells 95.8-99.5% 3 ml CD56 (Catalog #621) 17855 17855RF 17875 17875RF RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells 2. Purities shown as either a range or mean ± SD. WWW.STEMCELL.COM 23

IMMUNOLOGY RESEARCH PRODUCTS Human Total Lymphocyte Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR EasySep Direct Human Total Lymphocyte 96.7 ± 1.5% 1 ml 19655 19655RF Total Lymphocytes EasySep HLA Total Lymphocyte Enrichment: Complete Processing Kit for RosetteSep Human Total Lymphocyte Enrichment Cocktail 9.2-96.9% 2 ml 94. ± 2.% CD2 (Catalog #67) CD19 (Catalog #65) CD2 (Catalog #68) CD54 (NCAM) (Catalog #621) 19961HLA 19961HLARF 4 ml 15223 2 ml 15263 RosetteSep HLA Total Lymphocyte Enrichment Cocktail -- 25 ml 15263HLA 2 1 ml 15283HLA 2 Human Lymphoid Cell Isolation by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Lymphoid Cells EasySep Human Lymphoid Positive Selection Kit 97.9-99.9% 6 ml CD2 (Catalog #67) CD19 (Catalog #65) CD2 (Catalog #68) 18684 18684RF Human Innate Lymphoid Cell (ILC) Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Group 2 Innate Lymphoid Cells Pan-Innate Lymphoid Cells Leukapheresis Sample Leukapheresis Sample RosetteSep Human ILC2 Enrichment Kit EasySep Human ILC2 Enrichment Kit EasySep Human Pan-ILC Enrichment Kit.44-23% (77-18 fold enrichment) 13-78% (25-145 fold enrichment) 17-86% (198-1556 fold enrichment) 2 ml CD14 (Catalog #64) CD16 (Catalog #641) CD19 (Catalog #65) CD34 (Catalog #613) CD123 (Catalog #611) 15382 1 x 1 9 cells 17972 1 x 1 9 cells 17975 3 17975RF 3 Human Innate Lymphoid Cell (ILC) Isolation by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Group 2 Innate Lymphoid Cells Leukapheresis Sample EasySep Human ILC2 84-95% 2 x 1 9 cells CD14 (Catalog #64) CD16 (Catalog #641) CD19 (Catalog #65) CD34 (Catalog #613) CD123 (Catalog #611) 17782 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Purities shown as either a range or mean ± SD. 2. This kit carries the CE mark. 3. These kits enrich for group1, group 2, and group 3 innate lymphoid cells (ILC1, ILC2, and ILC3). 24 STEMCELL Technologies Inc.

Human Dendritic Cell Isolation by Negative Selection Pan-Dendritic Cells Myeloid Dendritic Cells Plasmacytoid Dendritic Cells EasySep Human Pan-DC Pre-Enrichment Kit EasySep Human Myeloid DC Enrichment Kit EasySep Human Plasmacytoid DC Enrichment Kit 4. - 8.% 1 x 1 9 cells 79. - 94.% 2 x 1 9 cells 87. - 97.% 2 x 1 9 cells CD14 (Catalog #64) CD19 (Catalog #65) CD2 (Catalog #68) CD34 (Catalog #613) CD56 (Catalog #621) 19251 19251RF 1961 1961RF 1962 1962RF Human Monocyte Isolation by Negative Selection EasySep Human Monocyte Enrichment Kit without CD16 Depletion 73. - 81.% 1 x 1 9 cells 1958 3 1958RF 3 Monocytes EasySep Human Monocyte EasySep Direct Human Monocyte 87. ± 5.% 1 x 1 9 cells CD14 (Catalog #64) CD16 (Catalog #641) CD36 (Catalog #684) 19359 19359RF 82.2 ± 8.4% 1 ml 19669 RosetteSep Human Monocyte Enrichment Cocktail 72. - 85.% 4 ml 1528 2 ml 1568 Human Granulocyte and Subset Isolation by Negative Selection Pan-Granulocytes PMNC EasySep Human Pan-Granulocyte EasySep Direct Human Pan-Granulocyte 97. - 99.% 1 x 1 9 cells 19259 CD16 (Catalog #641) 19259RF CD66b (Catalog #686) CD123 (Catalog #611) 98.4 ± 1.5% 1 ml 19659 Basophils PMNC EasySep Human Basophil 94. ± 2.5% 1 x 1 9 cells CD123 (Catalog #611) 17969 17969RF Neutrophils Eosinophils PMNC PMNC EasySep Human Neutrophil Enrichment Kit EasySep Direct Human Neutrophil EasySep Human Eosinophil 98. - 99.% 1 x 1 9 cells 19257 19257RF CD11b (Catalog #64) 95.3 ± 1.4% 1 ml CD16 (Catalog #641) 19666 CD66b (Catalog #686) 96.5 ± 2.5% 1 x 1 9 cells 17956 17956RF RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells; PMNC - Polymorphonuclear Cells 2. Purities shown as either a range or mean ± SD. 3. These kits isolate CD14 + CD16 + monocytes. WWW.STEMCELL.COM 25

IMMUNOLOGY RESEARCH PRODUCTS Human Myeloid Cell Isolation by Negative Selection Myeloid Cells RosetteSep HLA Myeloid Cell Enrichment Kit 68. - 98.% 2 ml CD11b (Catalog #64) CD33 (Catalog # 696) CD66b (Catalog #686) 15272HLA Human Myeloid Cell Isolation by Positive Selection CD14 + Cells Buffy Coat EasySep Human CD14 Positive Selection Kit II EasySep HLA Chimerism Buffy Coat CD14 Positive Selection Kit 97.8-99.7% 1 x 1 9 cells 93. ± 6.4% 3 ml CD14 (Catalog #64) CD36 (Catalog #684) 17858 17858RF 17878 17878RF CD15 + Cells PMNC, Buffy Coat EasySep Human CD15 Positive Selection Kit EasySep HLA Chimerism Whole Blood CD15 Positive Selection Kit 98.8 ±.8% 1 x 1 9 cells 99.2 ± 1.1% 6 ml 18651 18651RF 17881 17881RF CD33 + Cells Lysed EasySep Human CD33 Positive Selection Kit EasySep HLA Chimerism Whole Blood CD33 Positive Selection Kit 93. - 97.% 1 x 1 9 cells 6.2-79.6% 6 ml CD66b (Catalog #686) CD14 (Catalog #64) 18257 18257RF 17885 17885RF CD33 + CD66b + (Myeloid) Cells Lysed, Buffy Coat EasySep Human Myeloid Positive Selection Kit EasySep HLA Chimerism Whole Blood Myeloid Positive Selection Kit 96.2-99.% 1 x 1 9 cells CD66b (Catalog #686) CD14 (Catalog #64) 94.5 ± 4.1% 6 ml CD33 (Catalog #696) 18653 18653RF 17884 17884RF CD66b + Cells (Granulocytes) EasySep Human CD66b Positive Selection Kit 99.3-99.9% 6 ml CD66b (Catalog #686) 18682 18682RF CD271 + Cells Bone Marrow EasySep Human CD271 Selection Kit -- 2 x 1 9 cells Dextran (Catalog #626) 18659 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells; PMNC - Polymorphonuclear Cells 2. Purities shown as either a range or mean ± SD. 26 STEMCELL Technologies Inc.

Human Hematopoietic Progenitor Cell Isolation by Negative Selection Mobilized, BMMC EasySep Human Progenitor Cell Enrichment Kit 42. ± 5. fold CD34 + cell enrichment (bone marrow) 1 x 1 9 cells 1956 1956RF, CBMC EasySep Human Progenitor Enrichment Kit with Platelet Depletion 5. - 75.% 1 x 1 9 cells 19356 3 19356RF 3 Hematopoietic Progenitors Bone Marrow Cord Blood RosetteSep Human Bone Marrow Progenitor Cell Pre-Enrichment Cocktail RosetteSep Human Hematopoietic Progenitor Cell Enrichment Cocktail Complete RosetteSep Human Cord Blood Progenitor Enrichment Kit 25. ± 1. fold CD34 + cell enrichment 29. ± 9.% 4 ml 1527 2 ml 1567 4 ml CD34 (Catalog #613) 1526 2 ml 1566 29. ± 9.% 5 ml 15276 Lineage Negative Cells Cord Blood RosetteSep Human Cord Blood Debulking Cocktail 5. ± 1.% (CD34 + cells) 4 ml 15126 4 2 ml 15166 4 Human CD34 + Hematopoietic Progenitor Cell Isolation by Positive Selection Mobilized, CBMC, BMMC EasySep Human CD34 Positive Selection Kit 84. - 99.% 5 x 1 9 cells 1856 5 1856RF 5, Buffy Coat EasySep Human CD34 Positive Selection Kit 26. - 41.% 75 ml whole blood 37 ml buffy coat 1886 1886RF CD34 + Cells Complete Kit for Human CD34 + Cells 79. - 95.% 12 ml CD34 (Catalog #613) 1586 1586RF Cord Blood EasySep Human Cord Blood CD34 Positive Selection Kit II EasySep Human Cord Blood CD34 Positive Selection Kit III 91. ± 9.% 1 ml 87. ± 12% 1 ml 17896 6,7 17896RF 6,7 17897 6,8 17897RF 6,8 hesc and hipsc Cultures EasySep hesc-derived CD34 Positive Selection Kit 84. - 99.% 5 x 1 9 cells 18167 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells; CBMC - Cord Blood Mononuclear Cells; BMMC - Bone Marrow Mononuclear Cells; hesc - Human Embryonic Stem Cell; hipsc - Human Induced Pluripotent Stem Cell 2. Purities shown as either a range or mean ± SD. Purity data for 1856, 1886, and 1586 are reported relative to viable CD45 + cells. 3. This product is designed for use with samples that contain large numbers of platelets. 4. This product is recommended for debulking cord blood of lineage positive cells prior to freezing. 5. These kits are for use with previously frozen cord blood mononuclear cells. For isolation of CD34 + cells from fresh cord blood, please use 17896 and 17896RF. 6. These kits are for use with fresh cord blood. For isolation of CD34 + cells from previously frozen cord blood mononuclear cells, please use 1856 and 1856RF. 7. This kit contains antibodies for platelet depletion and is recommended for preenrichment of CD34 + cells from cord blood samples that contain large amounts of platelets. Platelets may affect the quality and purity of CD34 + cells if not depleted. 8. This kit does not contain antibodies for platelet depletion and is recommended for preenrichment of CD34 + cells from cord blood samples that contain few platelets or when platelet depletion is not desired. WWW.STEMCELL.COM 27

IMMUNOLOGY RESEARCH PRODUCTS Isolation of Other Human Cell Types by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY FOR EasySep Direct Human CTC Enrichment Kit 2.9-3.2 log depletion 1 ml CD326 (EpCAM) (Catalog #119) 19657 Circulating Epithelial Tumor Cells RosetteSep CTC Enrichment Cocktail Containing Anti-CD36 RosetteSep CTC Enrichment Cocktail Containing Anti-CD56 2.9 log depletion 3.2-4.4 log depletion 4 ml 15127 2 ml 4 ml CD326 (EpCAM) (Catalog #119) 15167 15137 2 ml 15177 Other Cell Types (Custom) Any Source EasySep Human Custom Enrichment Kit RosetteSep Human Custom Cocktail -- As requested -- 1939 1 1939RF 1 -- As requested -- 1539 1 Isolation of Other Human Cell Types by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY FOR EasySep Human Custom Positive Selection Kit -- As requested -- 1839 2 1839RF 2 EasySep Release Human Biotin Positive Selection Kit -- 1 x 1 9 cells Goat Anti-Mouse IgG (H+L) (Catalog #6138) 17653 3 EasySep Release Human PE Positive Selection Kit -- 1 x 1 9 cells -- 17654 4 Other Cell Types (Custom) Any Source EasySep Human PE Positive Selection Kit II EasySep Human FITC Positive Selection Kit II -- 1 x 1 9 cells -- 1 x 1 9 cells 17664 4 17664RF 4 5 x 1 9 cells 17694 4,5 17662 6 17662RF 6 EasySep Human Biotin Positive Selection Kit II -- 1 x 1 9 cells Dextran (Catalog #626) 17663 3 17663RF 3 EasySep Human APC Positive Selection Kit II EasySep Human "Do-It-Yourself" Selection Kit II -- 1 x 1 9 cells -- 1 x 1 9 cells 17661 7 17661RF 7 17699 8 17699RF 8 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Isolate any human cell type by negative selection. 2. Isolate any human cell type by positive selection. 3. Use with biotinylated antibodies. 4. Use with PE-conjugated antibodies. 5. This product includes 5 x 18551. 6. Use with FITC-conjugated antibodies. 7. Use with APC-conjugated antibodies. 8. Use your own mouse IgG 1 antibodies. 28 STEMCELL Technologies Inc.

Human Cell Depletion Products Human T Cell and Subset Depletion CELL TYPE SOURCE 1 PRODUCT NAME PURITY FOR CD3 + Cells RosetteSep Human CD3 Depletion Cocktail Typically 3. log depletion 4 ml 15621 2 ml 15661 CD4 + Cells RosetteSep Human CD4 Depletion Cocktail Typically 2. log depletion 4 ml 15622 CD4 (Catalog #616) 2 ml 15662 CD8 + Cells RosetteSep Human CD8 Depletion Cocktail Typically 2. log depletion 4 ml CD8a (Catalog #622) 15623 2 ml 15663 CD25 + Cells EasySep Human CD25 Positive Selection and Depletion Kit Typically 1.3 log depletion 1 x 1 9 cells CD25 (Catalog #6153) 17861 Human Monocyte Depletion CELL TYPE SOURCE PRODUCT NAME PURITY FOR Monocytes RosetteSep Human Monocyte Depletion Cocktail Typically 2.8 log depletion 4 ml CD14 (Catalog #64) CD16 (Catalog #641) 15628 2 ml CD36 (Catalog #684) 15668 Human Granulocyte and Subset Depletion CELL TYPE SOURCE PRODUCT NAME PURITY FOR Granulocytes RosetteSep Human Granulocyte Depletion Cocktail RosetteSep HLA Granulocyte Depletion Cocktail < 1% Granulocytes < 1% Granulocytes 4 ml 15624 2 ml 25 ml CD11b (Catalog #64) CD16 (Catalog #641) CD66b (Catalog #686) 15664 15664HLA 1 ml 15684HLA IgE + Cells RosetteSep Anti-Human IgE Tetramer -- 4 ml 1523 Depletion of Other Human Cell Types CELL TYPE SOURCE 1 PRODUCT NAME PURITY FOR EasySep Human CD45 Depletion Kit Typically 4. log depletion 2 x 1 9 cells 17898 2 17898RF 2 CD45 + Cells EasySep Human CD45 Depletion Kit RosetteSep Human CD45 Depletion Cocktail 2. - 4. log depletion Typically 3.6 log depletion 1 ml 18289 2 18289RF 2 4 ml 15122 2 2 ml 15162 2 GlyA + Cells EasySep Human Positive Glycophorin A Depletion Cocktail -- 1.6 x 1 9 cells GlyA (Catalog #1423) 18352 18352RF Red Blood Cells EasySep Red Blood Cell Depletion Kit Typically <1% red blood cells 1 ml GlyA (Catalog #1423) 1817 1817RF Dead Cells (Annexin V + ) Tissue Preparations EasySep Dead Cell (Annexin V + ) Removal Kit -- 1 x 1 9 cells -- 17899 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. - Peripheral Blood Mononuclear Cells 2. CD45 depletion is useful to enrich circulating non-hematopoietic tumor cells from peripheral blood. WWW.STEMCELL.COM 29

IMMUNOLOGY RESEARCH PRODUCTS Mouse Cell Isolation Products Mouse T Cell and Subset Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR T Cells Spleen EasySep Mouse T Cell 92. - 98.% 1 x 1 9 cells Pan-Naïve T Cells Spleen EasySep Mouse Pan-Naïve T Cell 9. - 97.% 1 x 1 9 cells CD3e (Catalog #615) CD9 (Catalog #624) 19851 19851RF 19848 19848RF CD4 + T Cells Spleen EasySep Mouse CD4 + T Cell 89. - 96.% 1 x 1 9 cells CD3e (Catalog #615) CD4 (Catalog #617) 19852 19852RF Naïve CD4 + T Cells Memory CD4 + T Cells Spleen Spleen EasySep Mouse Naïve CD4 + T Cell EasySep Mouse Memory CD4 + T Cell 9. - 95.% 1 x 1 9 cells 78. - 96.% 1 x 1 9 cells CD4 (Catalog #617) CD44 (Catalog #668) CD62L (Catalog #619) 19765 19765RF 19767 19767RF CD8 + T Cells Spleen EasySep Mouse CD8 + T Cell 87. - 95.% 1 x 1 9 cells CD3e (Catalog #615) CD8a (Catalog #623) 19853 19853RF Naïve CD8 + T Cells Spleen EasySep Mouse Naïve CD8 + T Cell 92. - 98.% 1 x 1 9 cells CD8a (Catalog #623) CD44 (Catalog #668) CD62L (Catalog #619) 19858 19858RF Mouse T Cell and Subset Isolation by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR CD9.2 + (Thy 1.2) Cells Spleen EasySep Mouse CD9.2 Positive Selection Kit II 97. - 99.% 2 x 1 9 cells CD9.2 (Catalog #6115) 18951 18951RF CD9.1 + (Thy 1.1) Cells Spleen, Lymph Node, EasySep Mouse CD9.1 Positive Selection Kit 93.5 ± 3.9% 2 x 1 9 cells CD9 (Catalog #624) 18958 18958RF CD4 + Cells Spleen EasySep Mouse CD4 Positive Selection Kit II 98.6 ±.4% 2 x 1 9 cells CD3e (Catalog #615) CD4 (Catalog #629) 18952 18952RF CD4 + CD62L + Cells Spleen EasySep Mouse CD4 + CD62L + T Cell 92. - 97.% 1 x 1 9 cells CD4 (Catalog #617) CD44 (Catalog #668) 18765 18765RF CD4 + CD25 + Cells Spleen EasySep Mouse CD4 + CD25 + Regulatory T Cell II 7. - 93.% 1 x 1 9 cells CD4 (Catalog #629) CD4 (Catalog #617) 18783 CD25 + Cells Spleen EasySep Mouse CD25 Regulatory T Cell Positive Selection Kit 8. - 93.% 1 x 1 9 cells CD4 (Catalog #617) 18782 18782RF CD8a + Cells Spleen EasySep Mouse CD8a Positive Selection Kit II 96.3 ± 1.4% 2 x 1 9 cells CD3e (Catalog #615) CD8a (Catalog #623) 18953 18953RF RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Purities shown as either a range or mean ± SD. 3 STEMCELL Technologies Inc.

Mouse B Cell Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR B Cells Spleen EasySep Mouse B Cell 94. - 98.% 1 x 1 9 cells CD19 (Catalog #66) 19854 2 19854RF 2 Pan-B Cells Spleen EasySep Mouse Pan-B Cell 91. - 98.% 1 x 1 9 cells CD19 (Catalog #66) CD138 (Catalog #635) 19844 3 19844RF 3 Mouse B Cell and Subset Isolation by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR CD19 + Cells Spleen EasySep Mouse CD19 Positive Selection Kit II 95. - 99.6% 2 x 1 9 cells CD19 (Catalog #66) 18954 18954RF CD138 + Cells Spleen, Lymph Node, Bone Marrow EasySep Mouse CD138 Positive Selection Kit 81.5 ± 4.9% 2 x 1 9 cells CD138 (Catalog #635) CD45R (Catalog #619) CD267 (Catalog #6116) 18957 18957RF Mouse NK Cell Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR NK Cells Spleen EasySep Mouse NK Cell 67. - 89.% 1 x 1 9 cells CD3e (Catalog #615) CD49b (Catalog #62) 19855 19855RF Mouse NK Cell Isolation by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR COMPATIBLE STAINIG CD49b + Cells Spleen EasySep Mouse CD49b Positive Selection Kit 74-9% 2 x 1 9 cells Dextran (Catalog # 626) 18755 18755RF Mouse Innate Lymphoid Cell (ILC) Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Group 2 Innate Lymphoid Cells Lung EasySep Mouse ILC2 Enrichment Kit 2.2-7.1% (3-11 fold enrichment) 1 x 1 9 cells CD45 (Catalog #63) CD9.2 (Catalog #6115) CD3e (Catalog #615) CD11b (Catalog #61) CD11c (Catalog #62) CD19 (Catalog #6112) Gr-1 (Catalog #628) CD161 (Catalog #613) TER119 (Catalog #633) TCR Gamma/Delta (Catalog #614) 19842 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Purities shown as either a range or mean ± SD. 2. This kit is designed for the isolation of conventional (B-2) B cells only. 3. This kit is designed to isolate all B cells, including conventional (B-2) B cells, B-1 B cells, and plasma cells. This kit is compatible for use with cells from disease models where malignant cells express CD43 or CD11b. WWW.STEMCELL.COM 31

IMMUNOLOGY RESEARCH PRODUCTS Mouse Dendritic Cell Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Pan-Dendritic Cells Spleen EasySep Mouse Pan-DC Enrichment Kit 54. - 76.% 2 x 1 9 cells CD3e (Catalog #615) CD11c (Catalog #62) CD19 (Catalog #66) F4/8 (Catalog #627) Ly6G (Catalog #631) TER119 (Catalog #633) NK1.1 (Catalog #613) 19763 19763RF Plasmacytoid Dendritic Cells Spleen EasySep Mouse Plasmacytoid DC 62. - 94.% 2 x 1 9 cells CD11c (Catalog #62) 19764 19764RF Mouse Monocyte Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Monocytes, Bone Marrow EasySep Mouse Monocyte 94.2 ± 1.5% 1 x 1 9 cells CD11b (Catalog #61) F4/8 (Catalog #627) 19861 19861RF Mouse Neutrophil Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Neutrophils, Bone Marrow EasySep Mouse Neutrophil Enrichment Kit 83. - 94.% () 8. - 9.% (Bone Marrow) 1 x 1 9 cells CD11b (Catalog #61) Gr-1 (Catalog #628) Ly6G (Catalog #631) 19762 19762RF RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Purities shown as either a range or mean ± SD. 32 STEMCELL Technologies Inc.

Mouse Myeloid Cell Isolation by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR CD11b + Cells Spleen, Bone Marrow, Lung, Brain EasySep Mouse CD11b Positive Selection Kit II 92.6 ± 3.% (Spleen) 98.4 ± 2.3% (Bone Marrow) 86.9 ± 7.6% (Lung) 94.2 ± 4.% (Brain) 2 x 1 9 cells CD11b (Catalog #61) 1897 1897RF CD11c + Cells Spleen, Cultured Bone Marrow EasySep Mouse CD11c Positive Selection Kit II with Spleen Dissociation Medium EasySep Mouse CD11c Positive Selection Kit II 86.8 ± 9.7% 2 x 1 9 cells 87. - 98.% 2 x 1 9 cells CD11c (Catalog #62) 18781 18781RF 1878 1878RF Mouse Hematopoietic Progenitor Isolation by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Hematopoietic Progenitor Cells Bone Marrow EasySep Mouse Hematopoietic Progenitor Cell 6. - 84.% 1 x 1 9 cells CD3 (Catalog #615) CD11b (Catalog #61) CD19 (Catalog #66) CD45R (Catalog #619) Gr-1 (Catalog #628) TER119 (Catalog #633) 19856 19856RF Mouse Hematopoietic Progenitor Isolation by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR SCA1 + Cells Bone Marrow EasySep Mouse Sca1 Positive Selection Kit 87. - 97.% 2 x 1 9 cells Sca1 (Catalog #632) 18756 18756RF CD117 + (c-kit) Cells Bone Marrow EasySep Mouse CD117 (ckit) Positive Selection Kit 88. - 95.% 2 x 1 9 cells Dextran (Catalog #626) 18757 18757RF RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Purities shown as either a range or mean ± SD. WWW.STEMCELL.COM 33

IMMUNOLOGY RESEARCH PRODUCTS Isolation of Other Mouse Cell Types by Negative Selection CELL TYPE SOURCE PRODUCT NAME PURITY 1 FOR Human Cells from Xenograft-Recipient Mice Bone Marrow, Spleen and Blood EasySep Mouse/Human Chimera 8. - 98.% 1 x 1 9 cells CD45R (Catalog #619) TER119 (Catalog #633) 19849 Other Cell Types (Custom) Any Source EasySep Mouse Custom Enrichment Kit -- As requested -- 1979 2 1979RF 2 Isolation of Other Mouse Cell Types by Positive Selection CELL TYPE SOURCE PRODUCT NAME PURITY FOR EasySep Mouse Custom Positive Selection Kit -- As requested -- 1879 3 1879RF 3 EasySep Release Mouse Biotin Positive Selection Kit -- 1 x 1 9 cells Goat Anti-Mouse IgG (H+L) (Catalog #6138) 17655 4 EasySep Release Mouse PE Positive Selection Kit -- 1 x 1 9 cells -- 17656 5 Other Cell Types (Custom) Any Source EasySep Mouse PE Positive Selection Kit -- 1 x 1 9 cells 17666 5 17666RF 5 -- 5 x 1 9 cells 17696 5,6 EasySep Mouse FITC Positive Selection Kit -- 1 x 1 9 cells Dextran (Catalog #626) 17668 7 17668RF 7 EasySep Mouse Biotin Positive Selection Kit -- 1 x 1 9 cells 17665 4 17665RF 4 EasySep Mouse APC Positive Selection Kit -- 1 x 1 9 cells 17667 8 17667RF 8 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Purities shown as either a range or mean ± SD. 2. Isolate any mouse cell type by negative selection. 3. Isolate any mouse cell type by positive selection. 4. Use with biotinylated antibodies. 5. Use with PE-conjugated antibodies. 6. This product includes 5 x 17666. 7. Use with FITC-conjugated antibodies. 8. Use with APC-conjugated antibodies. WALLCHART Frequencies & Percentages of Mouse Immune Cell Types www.stemcell.com/mousecellfreq 34 STEMCELL Technologies Inc.

Other Species Cell Isolation Products Rat Cell Isolation by Negative or Positive Selection, or Depletion CELL TYPE SELECTION METHOD SOURCE PRODUCT NAME PURITY 1 FOR T Cells Negative Spleen,, Lymph Node EasySep Rat T Cell 98.1 ± 1.2% 1 x 1 9 cells 19641 19641RF CD4 + T Cells Negative Spleen,, Lymph Node EasySep Rat CD4 + T Cell 97.2 ± 1.2% 1 x 1 9 cells 19642 19642RF CD8 + T Cells Negative Spleen,, Lymph Node EasySep Rat CD8 + T Cell 92.3 ± 3.1% 1 x 1 9 cells 19643 19643RF B Cells Negative Spleen,, Lymph Node EasySep Rat B Cell 94.1 ± 3.8% 1 x 1 9 cells 19644 19644RF Other Cell Types (Custom) Negative Any Source EasySep Rat Custom Enrichment Kit -- As requested 1969 2 1969RF 2 Any Cell Type (Custom) Positive Any Source EasySep Rat Custom Positive Selection Kit -- As requested 1869 3 1869RF 3 IgM + Cells Depletion Spleen,, Lymph Node EasySep Rat IgM Depletion Kit Typically 1.6 log depletion 1 x 1 9 cells 18644 18644RF Non-Human Primate Cell Isolation by Negative or Positive Selection CELL TYPE SELECTION METHOD SOURCE PRODUCT NAME Any Cell Type (Custom) Negative Any Source EasySep Non-Human Primate Custom Enrichment Kit Positive Any Source EasySep Non-Human Primate Custom Positive Selection Kit 1989 4 1989RF 4 1889 5 1889RF 5 Isolation of Cells from Other Species by Positive Selection CELL TYPE SOURCE PRODUCT NAME FOR EasySep PE Positive Selection Kit 1 x 1 9 cells 17684 6, 17684RF 6 EasySep FITC Positive Selection Kit 1 x 1 9 cells 17682 7, 17682RF 7 EasySep Biotin Positive Selection Kit 1 x 1 9 cells 17683 8, 17683RF 8 Any Cell Type Any Source EasySep APC Positive Selection Kit 1 x 1 9 cells 17681 9, 17681RF 9 EasySep Do-It-Yourself Selection Kit 1 x 1 9 cells 17698 1, 17698RF 1 EasySep Anti-Rat IgG2a Positive Selection Kit 2 x 1 9 cells 1899 11, 1899RF 11 EasySep Anti-Rat IgG2b Positive Selection Kit 2 x 1 9 cells 18992 12, 18992RF 12 EasySep Anti-Rat IgM Positive Selection Kit 2 x 1 9 cells 18994 13, 18994RF 13 RoboSep Reagent Kits (RF) contain an EasySep Selection Kit with RoboSep Buffer and 1-2 boxes of RoboSep Tip Racks. 1. Purities shown as either a range or mean ± SD 2. Isolate any rat cell type by negative selection. 3. Isolate any rat cell type by positive selection. 4. Isolate any non-human primate cell type by negative selection. 5. Isolate any non-human primate cell type by positive selection. 6. Use with PE-conjugated antibodies. 7. Use with FITC-conjugated antibodies. 8. Use with biotinylated antibodies. 9. Use with APC-conjugated antibodies. 1. Use with your own mouse IgG 1 antibody. 11. Use with your own rat IgG2a antibody. 12. Use with your own rat IgG2b antibody. 13. Use with your own rat IgM antibody. WWW.STEMCELL.COM 35

IMMUNOLOGY RESEARCH PRODUCTS Cell Isolation Magnets and Accessories EasySep Magnets PRODUCT NAME EasySep Magnet 18 The Big Easy EasySep Magnet 181 Easy 5 EasySep Magnet 182 EasyEights EasySep Magnet 1813 EasyPlate EasySep Magnet 1812 EasySep Magnet Stands PRODUCT NAME UNIT SIZE EasySep Magnet Stands EasySep Multistand Separate up to 4 samples at once using the EasySep Multistand. The multistand is designed to hold up to 4 EasySep Magnets or 4 The Big Easy EasySep Magnets. (Catalog #181) EasySep EasyStand Separate up to 6 samples at once using the EasySep EasyStand. Each EasyStand can hold a single EasySep Magnet, and up to 6 EasyStands can be linked together. (Catalog #1813) EasySep EasyStand 1813 1 1 stand EasySep EasyStand with EasySep Magnet 18131 1 stand & 1 x 18 Density Media 4 x EasySep EasyStand 18134 4 stands PRODUCT NAME UNIT SIZE 4 x EasySep EasyStand with EasySep Magnets 18135 4 stands & 4 x 18 6 x EasySep EasyStand 18136 6 stands Lymphoprep 781 7851 7811 7861 25 ml 5 ml 4 x 25 ml 6 x 5 ml 6 x EasySep EasyStand with EasySep Magnets 18137 6 stands & 6 x 18 EasySep Multistand 181 2 1 stand OptiPrep 782 25 ml HetaSep 786 796 2 ml 1 ml EasySep Multistand with EasySep Magnets EasySep Multistand with "The Big Easy" Magnets 184 181 1 stand & 4 x 18 1 stand & 4 x 181 RosetteSep DM-L 1575 1 ml RosetteSep DM-M 15725 1 ml SpinSep Density Medium 17531 1 ml SepMate Products Enzymes for Tissue Dissociation PRODUCT NAME SepMate -15 (IVD 3 ) 85415 8542 BLOOD VOLUME PROCESSED (ML).5-5 UNIT SIZE 1 tubes 5 tubes SepMate -15 (RUO 4 ) 86415 1 tubes SepMate -5 (IVD 3 ) 8545 8546 4-17 1 tubes 5 tubes SepMate -5 (RUO 4 ) 8645 1 tubes 1. The EasySep EasyStand facilitates the separation of one or more samples at one time. Up to 6 samples can be isolated simultaneously using EasySep magnets (sold separately) and linkable EasySep EasyStand units. 2. The EasySep Multistand facilitates the separation of up to 4 samples at one time. This system is compatible with EasySep magnets and "The Big Easy" EasySep magnets (magnets sold separately). 3. SepMate (IVD) is only available in select regions where it is registered as an In Vitro Diagnostic (IVD) device for the isolation of mononuclear cells from human whole blood or cord blood by density gradient centrifugation. 4. SepMate for Research Use Only (RUO) is available in regions where SepMate is not registered as an IVD device. PRODUCT NAME UNIT SIZE ACCUTASE 792 1 ml Collagenase Type I 792 5 ml Collagenase Type IV 799 1 ml Collagenase/Hyaluronidase (1X) 7912 1 ml Dispase (1 mg/ml) 7923 1 ml DNase I (1 mg/ml) 79 1 ml Spleen Dissociation Medium 7915 1 x 4 ml Trypsin-EDTA (.5%) 791 5 ml Trypsin in Citrate Saline 74 1 ml 36 STEMCELL Technologies Inc.