AACE/ACE Consensus Conference on Glucose Monitoring: An Update

Similar documents
QUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3?

Welcome and Introductions. R. Mack Harrell, MD, FACP, FACE, ENCU AACE President

An Evaluation of the Barriers to Patient use of Glucometer Control Solutions: A Survey of Patients, Pharmacists, and Providers

Diabetes Management with Continuous Glucose Monitoring & Multiple Daily Injections. Aaron Michels MD

Today s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures

Continuous Glucose Monitoring Devices Pharmacy Policy

Advances in Diabetes Care Technologies

The Diamond Study: Continuous Glucose Monitoring In Patients on Mulitple Daily Insulin Injections

Advances in Diabetes Care Technologies

November 20, Ms. Seema Verma Administrator Centers for Medicare and Medicaid Services 7500 Security Boulevard Baltimore, MD 21244

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

American Association for Cardiovascular and Pulmonary Rehabilitation (AACVPR)

Annual Stockholder Meeting May 30, confidently live life with ease

Product Theaters. Light refreshments provided by the American Diabetes Association will be served to the first 300 attendees.

Incorporating CGM Into Clinical Decision Making. Etie Moghissi, MD, FACE Clinical Associate Professor, David Geffen School of Medicine UCLA

Continuous Glucose Monitoring System

Continuous Glucose Monitoring System

Lessons From The Type 1 Diabetes Exchange

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

Continuous Glucose Monitoring System

Background USPSTF Guideline

Diabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE

Coverage and Coding of Continuous Glucose Monitors

Insulin Pumps - External

Corporate Medical Policy

Original Article. Nicholas B. Argento, MD 1 ; Katherine Nakamura, PhD 2 ABSTRACT

When Will CGM Replace SMBG? Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida

Clinical Value and Evidence of Continuous Glucose Monitoring

State of California Health and Human Services Agency Department of Health Care Services

Dear Representative Burgess, Representative DeGette, Senator King, Senator Crapo, and Senator Cardin:

See Important Reminder at the end of this policy for important regulatory and legal information.

This is a licensed product of Ken Research and should not be copied

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD

Advances in Diabetes Care Technologies

TABLE OF CONTENTS. HLC102A - Continuous Glucose Monitoring (CGM): Technologies and Global Markets

Diabetes Management: Current High Tech Innovations

Update on Continuous Glucose Monitoring (CGM) Technology in Diabetes. Elena Toschi, MD November 12, 2016

Shaping our future: a call to action to tackle the diabetes epidemic and reduce its economic impact

Objectives 2/13/2013. Figuring out the dose. Sub Optimal Glycemic Control: Moving to the Appropriate Treatment

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Target Audience. approach this patient case scenario, including identifying an

Introducing NCCN Academy for Excellence & Leadership in Oncology April Program Overview

Insulin Delivery and Glucose Monitoring Methods: Future Research Needs. Future Research Needs Paper Number 32

Insulin Pumps and Glucose Sensors in Diabetes Management

VIA ELECTRONIC SUBMISSION: September 10, 2018

What is a CGM? (Continuous Glucose Monitor) The Bionic Pancreas Is Coming

Clinical Policy: Glucagon-Like Peptide-1 (GLP-1) Receptor Agonists Reference Number: HIM.PA.53 Effective Date: Last Review Date: 02.

The Realities of Technology in Type 1 Diabetes

DSQC Overview. Scott Kuzner, Ph.D. USP Global External Affairs Director

AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY 2016 OUTPATIENT GLUCOSE MONITORING CONSENSUS STATEMENT

Friday, March 30th Annual Conference Vancouver, WA March st Education Sessions

PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS)

Flash Glucose Monitoring & Implantable Sensors

Making Sense of Glucose Monitoring. My Journey with Glucose Monitoring Over the Last 37 Years 8/7/2017

1. Continuous Glucose Monitoring

Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Original Policy Date

REPORT INTERPRETATION

Exercise Prescription in Type 1 Diabetes

DIABETES ADVOCATES TAKE ACTION!

Commissioning Statement. Flash Glucose Monitoring system (FreeStyle Libre ) March 2018

Cowen Investor Conference March confidently live life with ease

Continuous Glucose Monitoring

January 2017 Investor Presentation. confidently live life with ease

CONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID

ADVANCES IN DIABETES TECHNOLOGY: A FOCUS ON CONTINUOUS GLUCOSE MONITORING 9:15 10:15 AM

Performance-powered. The OneTouch. Ping insulin pump and meter-remote.

Name of Policy: Continuous or Intermittent Monitoring of Glucose in the Interstitial Fluid

Advances Towards the Bionic Pancreas.

Continuous Glucose Monitoring (CGM)

February 1, The Honorable Jeanne Shaheen United States Senate 520 Hart Senate Office Building Washington, DC Dear Senator Shaheen:

Self Monitoring of Blood Glucose (SMBG)

Comparing the use of SMBG vs. CGM data to Optimize Glucose Control in T2DM

Dexcom Current and Future Technology Innovations. Jorge Valdes Chief Technical Officer

ADAG Study Group Data Links A1C Levels with Empirically Measured Blood Glucose Values - New Treatment Guidelines Will Now be Needed

MEDICAL POLICY SUBJECT: CONTINUOUS GLUCOSE MONITORING SYSTEMS/ EXTERNAL INSULIN PUMP THERAPY FOR DIABETES EFFECTIVE DATE: 08/17/17

DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson

DIABETES CARE DEVICES MARKET IN BRAZIL, RUSSIA, INDIA & CHINA (BRIC)

DEMYSTIFYING INSULIN THERAPY

Type 1 Diabetes: diagnosis and management. Stakeholder workshop

Releasing Time to Care. A journey towards evidence informed practice in the monitoring of blood glucose in the frail elderly in Long Term Care.

Submitted to the House Energy and Commerce Committee. Federal Efforts to Combat the Opioid Crisis

Insulin Prior Authorization with optional Quantity Limit Program Summary

DISCLAIMER: ECHO Nevada emphasizes patient privacy and asks participants to not share ANY Protected Health Information during ECHO clinics.

8/5/2017. Disclosure to Participants. What is PCORI? Outline. To Test or Not To Test. What is PCORI? THE MONITOR TRIAL

EVALUATION OF GLUCOSE MONITORING TECHNOLOGIES FOR COST EFFECTIVE AND QUALITY CONTROL/MANAGEMENT OF DIABETES

NHS Leeds CCG. Policy for the Funding of Flash Glucose Monitoring (FlashGM) in Paediatrics and Adults

House Committee on Energy and Commerce House Committee on Energy and Commerce. Washington, DC Washington, DC 20515

Mary Ann Hodorowicz RDN, MBA, CDE, CEC (Certified

Alex Azar Secretary, Department of Health and Human Services

Clinical Policy: Glucagon-Like Peptide-1 (GLP-1) Receptor Agonists

DIAGNOSIS OF DIABETES NOW WHAT?

Commissioning Statement

NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP

06/13/17. A. Completed a comprehensive diabetes education program within the past two years; and

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE) Consideration of consultation responses on review proposal

The Dual Hormonal Artificial Pancreas in Diabetes Management. Medical Innovation Day Challenge

NEWS BRIEFING Diabetes and Cardiovascular Disease. Moderated by: Robert Eckel, MD University of Colorado

Real-Time Continuous Glucose Monitoring: From Application to Evaluation

Transcription:

Can You Manage Diabetes Without Glucose Monitoring? Didn t Think So! George Grunberger, MD, FACP, FACE Chairman, Grunberger Diabetes Institute Clinical Professor, Internal Medicine and Molecular Medicine & Genetics Wayne State University School of Medicine Professor, Internal Medicine Oakland University William Beaumont School of Medicine Visiting Professor, Internal Medicine First Faculty of Medicine, Charles University, Prague, Czech Republic President, American Association of Clinical Endocrinologists AACE/ACE Consensus Conference on Glucose Monitoring: An Update Agenda AACE/ACE GM Consensus Conference AACE/ACE Glucose Monitoring Consensus Conference Current Issues RegardingAccuracy, Safety and Access to Blood and Continuous Glucose Monitoring Systems Questions Addressed at Conference Findings and Recommendations Next Steps Q&A American Association of Clinical Endocrinologists (AACE) and American College of Endocrinology (ACE) to evaluate clinical science, utility and access to blood and continuous glucose monitoring held September 28-29, 2014, in Washington, D.C. Pillars To Support Action Pillars, comprised representatives from sectors needed to support a concerted and comprehensive action plan: Government/Regulatory, Payors & Employers Industry Medical/Scientific/Professional & Educational Societies Patient/Lay Organizations Question 1 What data support glucose monitoring (as distinct from glycemic control) as a means to prevent diabetic macro- and microvascular complications? A. Does frequency of glucose monitoring correlate with better outcomes? B. Which patients benefit the most from rigorous glucose monitoring? C. Does strip accuracy and/or CGM accuracy 1

Question 2 Should the FDA improve post-approval surveillance of glucose strip, glucose meter, CGM quality? A. Does sub-standard glycemic monitoring technology harm patients? If so, what data exist to support such a claim? Are all manufacturers required to report this data to the FDA? B. What is the current state of affairs at the FDA in post marketing meter and CGM surveillance? C. What enforcement options are available to the FDA and how are they implemented? Question 3 Do current private insurance and Medicare policies balance the need to provide patient access to high quality care and effective glucose monitoring and, if not, what policy changes are needed with respect to: A. Patient Access to BGM supplies B. Patient access to CGM technology (access by appropriate patients) C. Limited or lack of coverage for sensor-augmented insulin pump therapy and emerging semiautomated CGM/pump combinations? Question 4 What is the most effective way for the key stakeholders to achieve equitable, evidence-based, cost-effective federal regulation of glucose (blood, continuous) monitoring technology? Consensus Process There were two teleconferences held for each pillar representatives separately, led by 2 members of the writing group before the meeting itself The process was outlined, pillar representatives discussed their answers to the 4 questions posed by the conference and submitted supporting documents to the writing committee this allowed for a lot of preparatory work in advance Consensus Process Each group went to their breakout rooms led by members of the Consensus Writing Committee Answers to each of the four questions were discussed and notes were taken to build a Pillar consensus All attendees then met together and provided their respective answers The Writing Committee then met after the sessions to discover there was a strong alignment across all of the four Pillars and their representatives What Data Do We Have To Support Recommendations? What data support glucose monitoring (as distinct from glycemic control) as a means to prevent diabetic macroand microvascular complications? A. Does frequency of glucose monitoring correlate with better outcomes? B. Which patients benefit the most from rigorous glucose monitoring? C. Does strip accuracy and/or CGM accuracy 2

Does frequency of glucose monitoring T1D Exchange Clinic Registry 20,555 patients with T1D association between number of fingersticks and HbA1c after adjustments for confounders higher number of daily SMBG strongly associated (p<0.001) with lower HbA1c in all age groups and both in pump and MDI users Insurers need to consider that reducing restrictions on number of test strips may improve glycemic control in patients with T1D Diabetes Care 36:2009-2014,2013 Does frequency of glucose monitoring 2015 American Diabetes Association Standards of Medical Care in Diabetes patients on intensive insulin regimens should perform SMBG prior to meals and snacks, postprandially, at bedtime, prior to exercise, when they suspect hypoglycemia, after treating low glucose until they are normoglycemic and prior to critical tasks (e.g. driving) do the numbers: 8-12x per day Diabetes Care 38(Suppl 1):S33-S40,2015 Does use of CGM result in less hypoglycemia and lower A1c? 120 patients, T1D, HbA1c < 7.5%, randomized to SMBG vs. CGM, 26 weeks time spent in hypoglycemia less in CGM users (p = 0.03) time spent in normoglycemia increased in CGM users (p = 0.009) HbA1c lower in CGM users (p = 0.008) Diabetes Care 34:795-800,2011 Does use of CGM lead to improved glycemic control? 322 patients, T1D, SMBG vs.cgm, HbA1c 7-10%, 1 year lower HbA1c in CGM users (p < 0.001) in adults time spent in normoglycemia increased significantly (p = 0.02) N Engl J Med 359:1464-1476,2008 Diabetes Care 32:2047-2049,2009 Can use of CGM reduce severe hypoglycemia in patients with T1D with hypoglycemia unawareness? 35 patients with T1D, 1 year, retrospective review of records median rates of severe hypoglycemia reduced from 4 to 0 episodes/patient-year (p < 0.01) mean rates of severe hypoglycemia reduced from 8.1 to 0.6 (p = 0.005) HbA1c reduced from 8.1±1.2% to 7.6 ±1.0% Diabetes Care 36:4160-4162,2013 100 adults with T2D, not on prandial insulin, effect of intermittent CGM vs.smbg on HbA1c over 40 weeks significant HbA1c reduction in the CGM group (p < 0.0001) Diabetes Care 35:32-38,2012 3

Use of CGM in Medicare Population Glucose Meter Accuracy 38 patients: 31 with type 1 diabetes, average age 70 years (range 65-78), diabetes duration 31 years 28 on insulin pump therapy 29 using CGM regularly and 25 had both pre-and post-cgm use HbA1c results Regular CGM use associated with a decrease in mean HbA1c: 7.6 (0.9)% to 7.1 (0.9)%, (p<0.0001), maintained until the most recent HbA1c (7.2 [0.8]%, p=0.0145, average 37 months) Fewer reporting severe hypoglycemia (from 79% to 31%, p=0.0002), and lower rate of SH (0.37 to 0.12 per year, p=0.0007) Endocr Practice 20:1297-1302,2014 12 systems = 83% met the ISO 2003 standards Diab Tech & Therapeut 16:2014 43 systems; of 34 evaluated 7 failedto meet ISO 2003 standards J Diab Sci Technol 6:1060-1075,2012 5 systems, lot-to-lot variability; only 2 met ISO 2003 standards J Diab Sci Technol 6:1075-1086,2012 7 systems, 100 patients, only 3 metiso 2003, only 1 metiso 2013 standards J Diab Sci Technol 7:144-152,2013 27 systems, 18 manufacturers; 16 out of 27 fulfilled minimum accuracy requirements; i.e. more than 40% failedthe ISO 2003 standards Diabetes Technol Ther 12:221-231,2010 Glucose monitoring has upgraded the quality and safety of diabetes care Better glucose monitoring reduces hypoglycemia related hospitalizations and reduces healthcare costs Need for glucose monitoring depends on the antidiabetic therapies employed CGM may be best for patients with type 1 diabetes on complex insulin regimens and in a select group with type 2 diabetes who need intensive insulin therapy and are at high risk of hypoglycemia Glucose oxidase-based systems show unacceptably high failure rates to meet 2003 ISO standards and even higher failure rates to meet 2013 ISO standards A proliferation of unbranded and often inaccurate glucose monitoring systems has occurred, driven by mail order diabetes suppliers under the CMSmandated competitive bidding process Switching from branded to unbranded meters and glucose strips is frequently initiated by intermediary durable medical equipment (DME) suppliers. Such behavior should be inhibited by regulators and should not be tolerated by prescribers FDA should implement more rigorous pre-and post-marketing surveillance and apply existing enforcement options such as prohibiting the sale and marketing of devices that do not meet current standards for quality, including products made in other countries Standardization of adverse event data reported by manufacturers and harmonization of patient data from glucose monitoring devices is needed Technological advancements that will improve patient outcomes and reduce healthcare costs are impeded due to the restrictive regulatory climate Although CGM has shown to be beneficial, it has still not been fully accepted as standard of care in type 1 diabetes by some insurers and prescribers Providing more accurate glucose monitoring systems and insuring that these systems are used appropriately in patients with diabetes mellitus will improve the risk-benefit ratio of diabetes treatment Productive private/public stakeholder engagement can foster the provision of costeffective health care and real improvement in patient outcomes. 4

Published in Endocrine Practice vol. 21, May 2015 AACE/ACE Consensus Statement PROCEEDINGS FROM THE AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY CONSENSUS CONFERENCE ON GLUCOSE MONITORING George Grunberger, MD, FACP, FACE, Chair; Timothy Bailey, MD, FACP, FACE, ECNU; Pauline M. Camacho, MD, FACE; Daniel Einhorn, MD, FACP, FACE; Alan J. Garber, MD, PhD, FACE; Yehuda Handelsman, MD, FACP, FACE, FNLA; R. Mack Harrell, MD, FACP, FACE, ECNU; Howard M. Lando, MD, FACP, FACE; Bill Law Jr., MD, FACE, FACP; Jonathan D. Leffert, MD, FACP, FACE, ECNU; Eric A. Orzeck, MD, FACP, FACE For the Glucose Monitoring Consensus Conference Writing Committee Building on the Consensus Conference and Maintaining Ongoing Dialogue with Stakeholders Consensus Conference is a model for stakeholder engagement Demonstrates potential value of a National Diabetes Clinical Care Commissionrepresenting a partnership between private sector diabetes experts and diabetes specialists in federal agencies most active in diabetes care Legislation re-introduced in 114 th Congress and supported by AACE and the entire diabetes community (HR 1192, SR 586); we need 200 cosponsors to get a hearing (last session got to 183 in the House) Commission will provide a formal mechanism for federal agencies to receive consistent and direct clinical expertise and a practical perspective from professionals who work directly with patients with diabetes Commission will identify and evaluate current federal quality improvement activities and critical gaps in efforts to support clinicians in providing integrated, high quality care National Diabetes Clinical Care Commission Examples of Issues the Commission Could Help Address: Quality and safety of BGM systems sold under the Medicare Competitive Bidding Program through improved communications between FDA & CMS USPSTF diabetes screening recommendations (from 2008) that were inconsistent with NIDDK-sponsored research on diabetes screening and standards of care used in private sector Appropriate and timely deployment of new technologies to patients, e.g. bionic pancreas Groups Supporting The National Diabetes Clinical Care Commission Act Unintended Consequences of the Competitive Bidding Program Abbott Academy of Nutrition and Dietetics American Academy of Family Physicians American Academy of Ophthalmology American Association of Clinical Endocrinologists American Association of Diabetes Educators American Association of Kidney Patients American Clinical Laboratory Association American College of Cardiology American Diabetes Association American Optometric Association American Medical Association American Podiatric Medical Association American Society for Metabolic and Bariatric Surgeons American Society of Bariatric Physicians American Society of Nephrology Amgen Bayer Corporation Boehringer Ingelheim DexCom, Inc. diatribe Foundation Eli Lilly and Company Endocrine Society GlaxoSmithKline Healthcare Leadership Council Health Monitor Network Johnson & Johnson Juvenile Diabetes Research Foundation Lexicon Pharmaceuticals, Inc. Medtronic Merck National Association of Chain Drug Stores National Community Pharmacists Association National Kidney Foundation Novo Nordisk Obesity Action Coalition Pediatric Endocrine Society Renal Physicians Association Results for Life Roche Diagnostics VIVUS, Inc. VSP Vision Care YMCA of the USA Long-term survival is negatively affected by gaps in SMBG acquisition Many more beneficiaries in test markets went to partial SMBG 5

Unintended Consequences of the Competitive Bidding Program the disproportionate migration from full to partial SMBG led to 42 additional deaths in test markets Unintended Consequences of the Competitive Bidding Program more inpatient admissions among test beneficiaries migrating from full to partial SMBG more cost for those beneficiaries in test markets Is This What We Wanted to Happen? Thank you! Questions? 6