Study the Effect of the Quality Factor of the Transient Evoked Oto-acoustic Emissions (TEOAE)

Similar documents
Advanced otoacoustic emission detection techniques and clinical diagnostics applications

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

More robust estimates for DPOAE level at audiometric frequencies

Otoacoustic emission latency and cochlear mechanics

Cochlear anatomy, function and pathology II. Professor Dave Furness Keele University

OtoAcoustic Emissions (OAE s)

A Review of the Effectiveness of Otoacoustic Emissions for Evaluating Hearing Status After Newborn Screening

Fine structures in hearing thresholds and distortion product otoacoustic emissions

3:538 Seminar: Hearing Science Otoacoustic Emissions Spring, 2009

FOUR COUNTER-ARGUMENTS FOR SLOW-WAVE OAEs

Backward Propagation of Otoacoustic Emissions

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Sources and Mechanisms of DPOAE Generation: Implications for the Prediction of Auditory Sensitivity

Auditory System Feedback

Plural Publishing Newsletter Spring Otoacoustic Emissions (OAEs): A 30-Year Perspective. James W. Hall III, Ph.D. University of Florida

Chapter 3: Anatomy and physiology of the sensory auditory mechanism

Signals, systems, acoustics and the ear. Week 5. The peripheral auditory system: The ear as a signal processor

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

Understanding Otoacoustic Emissions Generation

Acoustics, signals & systems for audiology. Psychoacoustics of hearing impairment

Can components in distortion-product otoacoustic emissions be separated?

Half-Octave Shift in Mammalian Hearing Is an Epiphenomenon of the Cochlear Amplifier

HST 721 Efferent Control Lecture October 2004

Lecture 3: Perception

HST 721 Lecture 4: Mechanics, electromotility and the cochlear amplifier

FALSE POSITIVE DP GRAMS

Educational Module Tympanometry. Germany D Germering

On the physiological location of otoacoustic emissions

Introduction. IAPA: June 04 1

Trajectory of the Aging Cochlea

Deafness and hearing impairment

FIFTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA. Invited Paper LINEAR RESPONSE OF THE COCHLEA

Rippling pattern of distortion product otoacoustic emissions evoked by high-frequency

P T P V U V I. INTRODUCTION. II. MODEL FORMULATION A. Cochlear fluid dynamics.

Mechanisms of Mammalian Otoacoustic Emission and their Implications for the Clinical Utility of Otoacoustic Emissions

mously with greater accuracy for mid and high frequencies, compared to the accuracy that is achieved at lower frequencies.

ABSTRACT. Professor Sandra Gordon-Salant and Assistant Professor Tracy Fitzgerald, Department of Hearing and Speech Sciences

INTRODUCTION I. DEFINITIONS AND BACKGROUND

EMANATIONS FROM RESIDUUM OSCILLATIONS IN HUMAN AUDITORY SYSTEM

AUDL GS08 and GAV1: 2013 Final exam page 1/13. You must complete all sections. Label all graphs. Show your work!

Outer Hair Cells in the Cochlea

Mechanical Properties of the Cochlea. Reading: Yost Ch. 7

The clinical Link. Distortion Product Otoacoustic Emission

Update on Otoacoustic Emissions: Basic Science to Clnical Application. Morning Session

Required Slide. Session Objectives

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

Intro to Audition & Hearing

The origin of SFOAE microstructure in the guinea pig

Auditory Physiology PSY 310 Greg Francis. Lecture 29. Hearing

PSY 310: Sensory and Perceptual Processes 1

Proceedings of Meetings on Acoustics

Hearing. By: Jimmy, Dana, and Karissa

FINE STRUCTURE DISTORTION PRODUCT OTOACOUSTIC EMISSION DURING PREGNANCY

Effect of the Attachment of the Tectorial Membrane on Cochlear Micromechanics and Two-Tone Suppression

Representation of sound in the auditory nerve

Processing of sounds in the inner ear

Hearing. istockphoto/thinkstock

Carrick L. Talmadge National Center for Physical Acoustics, University of Mississippi, University, Mississippi 38677

I. INTRODUCTION. J. Acoust. Soc. Am. 111 (1), Pt. 1, Jan /2002/111(1)/271/14/$ Acoustical Society of America

Prescribe hearing aids to:

Comparison of Distortion Product Otoacoustic Emission Amplitude between Normal Hearing Male and Female Subjects

Estimating auditory filter bandwidth using distortion product otoacoustic emissions

Physiological basis of sound design. Prof. Dr. med. Eckhard Hoffmann Dipl.-Ing. (FH) Steffen Kreikemeier Aalen University of Applied Sciences

The origin of short-latency transient-evoked otoacoustic emissions

The Structure and Function of the Auditory Nerve

Brad May, PhD Johns Hopkins University

Citation for published version (APA): van Hengel, P. W. J. (1996). Emissions from cochlear modelling. Groningen: s.n.

Power spectra for transient-evoked otoacoustic emissions

Chapter 11: Sound, The Auditory System, and Pitch Perception

Fine Structure in Distortion Product Otoacoustic Emissions and Auditory Perception

Otoacoustic Estimates of Cochlear Tuning: Testing Predictions in Macaque

A truly remarkable aspect of human hearing is the vast

Role of Distortion Product Otoacoustic Emissions (DPOAES) In Detecting Early Hearing Impairment in Individuals With Normal Pure Tone Audiometry (PTA)

Submitted Oct 29, 2007; Accepted: Mar 14, 2008; Published: Apr 10, 2008

THE INTERPLAY BETWEEN ACTIVE HAIR BUNDLE MECHANICS AND ELECTROMOTILITY IN THE COCHLEA

J Jeffress model, 3, 66ff

Can You Hear Me Now?

ORIGINAL ARTICLE. High-Frequency Hearing Influences Lower-Frequency Distortion-Product Otoacoustic Emissions

Frequency refers to how often something happens. Period refers to the time it takes something to happen.

FAST MOTILITY OF ISOLATED MAMMALIAN AUDITORY SENSORY CELLS. Hans P. Zenner, Ulrike Zimmermann and Alfred H. Gitter

Audiology Curriculum Post-Foundation Course Topic Summaries

CASE REPORT. AUDITORY NEUROPATHY WITH BILATERAL BAT EARS A RARE CASE REPORT A. Sivakumar 1, V. Narendrakumar 2

Proceedings of Meetings on Acoustics

Swept - Tone Evoked Otoacoustic Emissions: Stimulus Calibration and Equalization

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

The frequency analysis of the cochlea a review of Nobili et al (1998) and Ruggero et al (1992)

A cochlear AGC model, proposing a new type of cochlear non-linearity

Possible mechanisms of cochlear two-tone suppression represented by vector subtraction within a model

Attention Effects on Distortion- Product Otoacoustic Emissions with Contralateral Speech Stimuli

Acoustics Research Institute

Hearing. PSYCHOLOGY (8th Edition, in Modules) David Myers. Module 14. Hearing. Hearing

Hearing Lectures. Acoustics of Speech and Hearing. Auditory Lighthouse. Facts about Timbre. Analysis of Complex Sounds

(Otoacoustic Emissions and Automated ABR)

Terri-Lynn Gagnon M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

Chapter 3. of energy that moves through air, water and other matter, in waves of pressure.

ENT 318 Artificial Organs Physiology of Ear

Hearing Screening, Diagnostics and Intervention

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

Transcription:

Research in Otolaryngology 217, 6(4): 47-4 DOI:.923/j.otolaryn.21764.1 Study the Effect of the Quality Factor of the Transient Evoked Oto-acoustic Emissions (TEOAE) Adnan AL-Maamury *, Dhifaf Ahmed Al-Mustansiriyah University, College of Science, Department of Physics, Baghdad, Iraq Abstract The effect and role of the quality factor in the nonlinear model was studied in this research. The nonlinear model is one of a set of models that deals with the relationship between frequency and latency of transient evoked otoacoustic emission (TEOAE). Different values of the quality factor were used in non-linear model calculations to determine values which give the best results. For more accurate results, a range of stimulus levels were used. After performing calculations for different quality factor values and stimulus levels, small quality factor values less than show good results for most of stimulus levels, while large values greater than give less With regard to stimulus levels, the results were different, with stimulus levels, 6 and 7 results are good and accurate. As for the rest of the levels, the results were less accurate, results of stimulus levels db and 6 db are better compared to other levels. Keywords Quality Factor, Stimulation Levels, Nonlinear Model, TEOAEs, Latency, Frequency 1. Introduction Presence of the otoacoustic emissions on the basis of mathematical models of cochlear nonlinearity predefined by Thomas Gold in 19s. However, one was not able to measure OAEs up to the year 197s, when technology researchers allow recording these responses by microphones very sensitive placed in the external hearing channel [1]. OAE is the first to experimentally interpreted in 1978 by David Kemp [2], which was discovered the OAEs measurement in the ear canal arises from the nature of the secondary process active in hearing [3], And showed that otoacoustic emissions are generated inside the ear in human cochlea by having a different number of mechanical and cellular reasons [4, ]. Narrow band otoacoustic emissions will respond to acoustic stimulation when there is evoked emissions or non-respond to acoustic stimulation in the absence of spontaneous emissions [6]. In recent years, the discovery of acoustic emission has led to expand our understanding of the process of hearing. Knowledge of OAEs resulted in explanation of certain physiological and anatomical findings that were either newly discovered or did not explain for several years. So, the discovery has led to a good understanding of the work of cochlear system of the IHCs [7]. Otoacoustic emissions that are produced by the low-level cochlea are measured by sending the sounds to the middle ear through a probe that * Corresponding author: dr.almaamury@gmail.com (Adnan AL-Maamury) Published online at http://journal.sapub.org/otolaryn Copyright 217 Scientific & Academic Publishing. All Rights Reserved contains a small microphone and a loudspeaker that converts the resulting sound into digital and is processed by an electronic device placed in the ear canal. The sounds are transferred to the external ear [8]. As it's known that OAEs are generated from two distinct mechanisms: an active non-linear element included the OHCs, and passive linear reflection of the travelling wave along the basilar membrane. Talmadge succeeded in applying a model of the cochlear several years after the discovery of otoacoustic emissions, which is a physiological process produced in the active mammalian cochlea. According to this model, sound waves located along the basilar membrane play an important role in generating spontaneous otoacoustic emissions that transmit the acoustic signal to the channel External ear through middle ear []. Through cochlea models, acoustic emissions are generated and sent back with conditions the resistance transverse of the resonant ton topically [11]. Based on the knowledge of the mechanism and behavior of the outer hair cells in the cochlea, several models of the feedback mechanism have been developed. These models, whether non-local and non-linear, should be comprehensive in the cochlea [13]. In the past decades, the external hair cells that are associated with the basilar membrane and tectorial membrane have been tested and comparing this pairing with experimental data which resulted in a high number of free parameters that reached a high degree of complexity [14]. Theoretical interpretation of experimental data helps the researcher to provide new diagnostic techniques for the design and improvement of cochlear function. Cochlear models are a useful tool for understanding the basic cochlear physiology and their use in running numerical experiments as an input to the model from feeding a particular type of

48 Adnan AL-Maamury et al.: Study the Effect of the Quality Factor of the Transient Evoked Oto-acoustic Emissions (TEOAE) stimulus. These experiments were compared with the real analog experiments and the results were compared in two stage: stage I, refining and validating the model; stage II, using the model to predict cochlear behavior and access to experimental techniques beyond their range [1, 16]. Using a limited number of free parameters, many cochlear models, including active, linear and nonlinear terms, have been discussed to plan the active feedback mechanism of the cochlear function. Linear models in the frequency domain can be effectively solved using numerical and analytical approximations at low computational costs. The same feature applies to nonlinear models which are a major feature of the physiology of cochlear and can be solved using the disorder system [17]. Finally, the discovery of OAEs Allows hypotheses are introduced to account for many of the psychoacoustical phenomena including the microstructures of behavioral sensitivity and loudness improve which were vague in terms of traditional models of the auditory system [9]. 2. Methods The description of a first approximation for eq.(1) and eq.(2), the simple passive cochlea model is used with one dimension [14]. Model used in this work is the nonlinear and the nonlocal. As in Adnan (21) [18], Moleti (29) [14] and Elliott (27) [19], the main equations are described as follows: 2 pp(xx,,tt) 2 xx = 2ρρ HH ξξ (1) ξξ + γγ bbbb ξξ + ωω 2 bbbb ξξ = ρρ (2) σσ bbbb Equation (2) describes the passive mechanism of the cochlea, which in turn only leads to differential fluid pressure. The active mechanism is proportional to p or ξ, which is added to basic equation to the basilar membrane associated with the outer hair cells [2]. The simplest form for each ton topic place is schematized by the relationship between angular frequency and position [21]. ωω bbbb (xx) = ωω ee kkkk xx + ωω1 (3) γγ bbbb (xx) = γγ ee kkkk xx + γγ1 (4) The nonlinear model is divided as active and passive as following: ξξ + ΓΓ (xx,ξξ) ξξ + cos 2 ρρ (xx)ξξ = () σσ bbbb The following equation describe the non linear model. ξξ + [ ΓΓ ρρ ΓΓ ρρ ΓΓ aa ( 1 tanh 2 ( ξξ ) ] ξξ + ωω 2 ξξ = ρρ (6) σσ ξξ bbbb ssssss. Equation (6) is divided to parts according to the value of (ξξ) as following: (1) When ξξ <<< ξξ ssssss. This means ξξ So [1 tanh 2 ( ξξ ) ] = 1 ξξ ssssss. Equation (6) becomes ξξ ΓΓ aa ξξ + ωω 2 ρρ ξξ = (7) σσ bbbb Equation (7) describes the active model, this model depend on (ΓΓ aa ) (2) When ξξ >>> ξξ ssssss. So the value of [ 1 tanh 2 ( ξξ ) ] = ξξ ssssss. Equation (6) becomes: ξξ + ΓΓ ρρ ξξ + ωω 2 ρρ ξξ = (8) σσ bbbb Equation (8) describes the passive model, this model depend on ΓΓ pp ΓΓ tttttt = ΓΓ aa when ξξ<<< ξξ ssssss. ΓΓ tttttt = ΓΓ pp when ξξ >>> ξξ ssssss. γγ = ΓΓ pp ΓΓ aa ΓΓ pp γγ = 1 ΓΓ aa ΓΓ pp (9) Where ΓΓ aa =.. ΓΓ pp The local passive quality factor QQ(xx) = ωω bbbb (xx) () γγ bbbb (xx) Where: kkkk = kkkk and ωω 1 = γγ 1 =, QQ(xx) = QQ = ωω (11) γγ Q does not depend on the frequency scale and there is no characteristic frequency scale such as (ωω 1 ), so that the maps of equations (3, 4 and ) do not clearly break the scale fixed symmetry, where QQ is a constant [2]. 3. Results and Discussion One of models that studies the relationship between frequency and latency of otoacoustic emission is nonlinear model. The purpose of this research is to improve the results of the calculations of the nonlinear model and to obtain more The quality factor is one of the most important factors in the nonlinear model. In order to obtain the best results, a series of calculations were performed using the nonlinear model using different stimulus levels (3,,, 6, 7, 8 and 9) db. For each stimulus level of this group, the calculations were performed for a set of quality factor (2, 4, 6, 8,, 12, 14, 16, 18 and 2). The purpose of this series of calculations is to conduct a comprehensive survey of the values of the quality factor in order to determine the most accurate results of the otoacoustic emission, especially the relationship between frequency and latency. The results were obtained in this work are classified as follows:

Research in Otolaryngology 217, 6(4): 47-4 49 1 Stimulus level 3 db using the stimulus level 3 db with all the values of the The results obtained using the quality factor values (2, 4, 6 and 8) are good and accurate, while other results are less accurate. Figure 1 shows the relationship between the frequency and latency of the otoacoustic emissions of the stimulus level 3 db, which includes four different cases. The four cases represent four curves which are as follows: frequency and latency of stimulus level 3 db using quality frequency and latency of stimulus level 3 db using quality frequency and latency of stimulus level 3 db using quality frequency and latency of stimulus level 3 db using quality 2- Stimulus level db using the stimulus level db with all the values of the The results obtained using the quality factor values (2, 4, 6 and 8) are good and accurate, while other results are less accurate. Figure 2 shows the relationship between the frequency and latency of the otoacoustic emissions of the stimulus level db, which includes four different cases. The four cases represent four curves which are as follows: frequency and latency of stimulus level db using quality frequency and latency of stimulus level db using quality frequency and latency of stimulus level db using quality frequency and latency of stimulus level db using quality 3- Stimulus level db using the stimulus level db with all the values of the The results obtained using the quality factor values (2, 4, 6, 8,, 12, 14, 16, 18 and 2) are good and accurate. Figure 3 shows the relationship between the frequency and latency of the otoacoustic emissions of the stimulus level db, which includes ten different cases. The ten cases represent ten curves which are as follows: - The fifth curve represents the relationship between factor value is. 6- The sixth curve represents the relationship between factor value is 12. 7- The seventh curve represents the relationship between frequency and latency of stimulus level db using quality factor value is 14. 8- The eighth curve represents the relationship between factor value is 16. 9- The ninth curve represents the relationship between factor value is 18. - The tenth curve represents the relationship between 4- Stimulus level 6 db using the stimulus level 6 db with all the values of the The results obtained using the quality factor values (2, 4, 6, 8,, 12, 14, 16, 18 and 2) are good and accurate. Figure 4 shows the relationship between the frequency and latency of the otoacoustic emissions of the stimulus level 6 db, which includes ten different cases. The ten cases represent ten curves which are as follows:

Adnan AL-Maamury et al.: Study the Effect of the Quality Factor of the Transient Evoked Oto-acoustic Emissions (TEOAE) - The fifth curve represents the relationship between factor value is. 6- The sixth curve represents the relationship between factor value is 12. 7- The seventh curve represents the relationship between frequency and latency of stimulus level6 db using quality factor value is 14. 8- The eighth curve represents the relationship between factor value is 16. 9- The ninth curve represents the relationship between factor value is 18. - The tenth curve represents the relationship between fiting spline level 3 3 2 2 1 1 2 3 4 6 Figure 1. Shows the relationship between the frequency and latency of the transient evoked otoacoustic emission (TEOAE), for the stimulus level 3 db and quality factor (Q= 2, 4, 6, 8) 3 Fitiing spline Level 2 2 1 1 2 3 4 6 Figure 2. Shows the relationship between the frequency and latency of the transient evoked otoacoustic emission (TEOAE), for the stimulus level db and quality factor (Q= 2, 4, 6, 8)

Research in Otolaryngology 217, 6(4): 47-4 1 3 2 2 fiting spline Level Q Q12 Q14 Q16 Q18 1 1 2 3 4 6 Figure 3. Shows the relationship between the frequency and latency of the transient evoked otoacoustic emission (TEOAE), for the stimulus level db and quality factor (Q= 2, 4, 6, 8,, 12, 14, 16, 18, 2) 3 2 2 fiting spline Level 6 Q Q12 Q14 Q16 Q18 1 1 2 3 4 6 Figure 4. Shows the relationship between the frequency and latency of the transient evoked otoacoustic emission (TEOAE), for the stimulus level 6 db and quality factor (Q= 2, 4, 6, 8,, 12, 14, 16, 18, 2) - Stimulus level 7 db using the stimulus level 7 db with all the values of the The results obtained using the quality factor values (2, 4, 6, 8,, 12, 14, 18 and 2) are good and accurate, while other result for quality factor (16) is less accurate. Figure shows the relationship between the frequency and latency of the otoacoustic emissions of the stimulus level 7 db, which includes nine different cases. The nine cases represent nine curves which are as follows: - The fifth curve represents the relationship between factor value is. 6- The sixth curve represents the relationship between factor value is 12.

2 Adnan AL-Maamury et al.: Study the Effect of the Quality Factor of the Transient Evoked Oto-acoustic Emissions (TEOAE) 7- The seventh curve represents the relationship between frequency and latency of stimulus level7 db using quality factor value is 14. 8- The eighth curve represents the relationship between factor value is 18. 9- The ninth curve represents the relationship between 6- Stimulus level 8 db using the stimulus level 8 db with all the values of the The results obtained using the quality factor values (4, 16 and 2) are good and accurate, while other results are less accurate. Figure 6 shows the relationship between the frequency and latency of the otoacoustic emissions of the stimulus level 8 db, which includes three different cases. The three cases represent three curves which are as follows: frequency and latency of stimulus level 8 db using quality frequency and latency of stimulus level 8 db using quality factor value is 16. frequency and latency of stimulus level 8 db using quality 7- Stimulus level 9 db using the stimulus level 9 db with all the values of the The results obtained using the quality factor values (6, 8 and 12) are good and accurate, while other results are less accurate. Figure 7 shows the relationship between the frequency and latency of the otoacoustic emissions of the stimulus level 9 db, which includes three different cases. The three cases represent three curves which are as follows: frequency and latency of stimulus level 9 db using quality frequency and latency of stimulus level 9 db using quality frequency and latency of stimulus level 9 db using quality factor value is 12. 3 2 2 fiting spline level 7 Q Q12 Q14 Q18 1 1 2 3 4 6 Figure. Shows the relationship between the frequency and latency of the transient evoked otoacoustic emission (TEOAE), for the stimulus level 7 db and quality factor (Q= 2, 4, 6, 8,, 12, 14, 18, 2)

Research in Otolaryngology 217, 6(4): 47-4 3 fiting spline Level 8 Q16 3 2 2 1 1 2 3 4 6 Figure 6. Shows the relationship between the frequency and latency of the transient evoked otoacoustic emission (TEOAE), for the stimulus level 8 db and quality factor (Q= 4, 16, 2) Fiting spline Level 9 Q12 3 2 2 1 1 2 3 4 6 Figure 7. Shows the relationship between the frequency and latency of the transient evoked otoacoustic emission (TEOAE), for the stimulus level 9 db and quality factor (Q= 6, 8, 12) 4. Conclusions Based on the results obtained in this work with respect to the effect of the quality factor and stimulus level on the accuracy of the results of the otoacoustic emission, we conclude that the use of the low values of the quality factor in the non-linear model produces better results and more accurate than the high values. These results are compatible with most stimulus levels, while with high values give different results and less accuracy. As for the stimulus levels, the results given were mixed, where the results are good with low quality factor and vary with high values and the best and accurate results were stimulus levels, 6 and 7 db. The results obtained in this work are consistent with previous studies [22-2]. Symbols BM is the basilar membrane xx is the longitudinal coordinate along the BM t is the time. p is the differential fluid pressure on the BM ρρ is the fluid density ξξ is the (BM) transverse displacement at the longitudinal position (x) and time (t) γγ bbbb dissipation constant of the local BM σσ bbbb is the BM of the surface density ωω bbbb the resonance frequency of the local BM.

4 Adnan AL-Maamury et al.: Study the Effect of the Quality Factor of the Transient Evoked Oto-acoustic Emissions (TEOAE) REFERENCES [1] W. E. Brownell, C. R. Bader, D. Bertrand, and Y. de Ribaupierre, "Evoked Mechanical Responses of Isolated Outer Hair Cells", Science 227, 194-196, (198). [2] D. T. Kemp, Stimulated acoustic emissions from within the human auditory system. The Journal of the Acoustical Society of America, vol. 64, no., pp. 1386 91, (1978). [3] J. Heitmann, B. Waldmann, H-U. Schnitzler, P. K. Plinkert, HP. Zenner, "Suppression of Distortion Product Otoacoustic Emissions (DPOAE) Near 2f1 f2 Removes DP-Gram Fine Structure Evidence for a Secondary Generator", J. Acoust. Soc. Am. 3, 127-131, (1998). [4] K. W. Chang and S. J. Norton, Efferently mediated changes in the quadratic distortion product (f2f1), The Journal of the Acoustical Society of America, vol. 2, no. 3, (1997). [] S. G. Kujawa, M. Fallon, R. A. Skellett, and R. P. Bobbin, Time-varying alterations in the f2-f1 DPOAE response to continuous primary stimulation. II. Influence of local calcium dependent mechanisms. Hearing research, vol. 97, no. 1-2, pp. 13 64, (1996). [6] D. C. Mountain, A. E. Hubbard, "Rapid Force Production in the Cochlea", US National Library of Medicine National Institutes of Health, Hear Res. 42, 19-22, (1989). [7] D. T. Kemp, and A. M. Brown, "A Comparison of Mechanical Nonlinearities in the Cochleae of Man and Gerbil from Ear Canal Measurements", in Hearing-Physiological Bases and Psychophysics, edited by R. Klink and R. Hartmann (Springer, Berlin), pp. 82-88, (1983). [8] B. S. Dinesh, P. C. BabuSingh Verma, ''Role of Transient Evoked Otoacoustic Emission Beyond screening of Hearing Impairment: A Study of Cases'', journal of Indian J Otolaryngol Head Neck Surg, vol. 6, no. 2, pp. 134-139, (212). [9] D. T. Kemp, "The Evoked Cochlear Mechanical Responses and the Auditory Microstructure-Evidence for a New Element in Cochlear Mechanics", Scand. Audiol. Suppl. 9, -47, (1979). [] R. Probst, R., Lonsbury-Martin, B. L., and Martin, G. K. A review of otoacoustic emissions, J. Acoust. Soc. Am. 89, 227 267, (1991). [11] C. L. Talmadge, A. Tubis, G. R. Long, and P. Piskorski, Modeling otoacoustic emission and hearing threshold fine structures, J. Acoust. Soc. Am. 4, 117 143, (1998). [12] R. Nobili, and F. Mammano, Biophysics of the cochlea II: Stationary nonlinear phenomenology, J. Acoust. Soc. Am. 99, 2244 22, (1996). [13] E. de Boer and A. L. Nuttall, Properties of amplifying elements in the cochlea, in Biophysics of the Cochlea: From Molecules to Models, edited by A. W. Gummer (World Scientific, Singapore), pp. 331 342, (23). [14] A. Moleti, N. Paternoster, D. Bertaccini, R. Sisto, and F. San just, Otoacoustic emissions in time-domain solutions of nonlinear non-local cochlear models, J. Acoust. Soc. Am. 126, 242 236, (29). [1] S. T. Neely, and D. O. Kim, A model for active elements in cochlear biomechanics, J. Acoust. Soc. Am. 79, 1472 148, (1986). [16] K. M. Lim, and C. R. Steele, A three-dimensional nonlinear active cochlear model analyzed by the WKB-numeric method, Hear. Res. 17, 19 2, (22). [17] R. Sisto, A. Moleti, N. Paternoster, T. Botti, and D. Bertaccini, Different models of the active cochlea, and how to implement them in the state-space formalism, J. Acoust. Soc. Am. 128, 1191 122, (2). [18] A. M. Al-Maamury "Study the Otoacoustic Emission Generation by using Nonlinear Model", Elixir Phys. & Anatomy 8, 362-366, (21). [19] S. J. Elliott, E. M. Ku, and B. Line ton, A state space model for cochlear mechanics, J. Acoust. Soc. Am. 122, 279 2771, (27). [2] A. Moleti and A.M. Al-Maamury, D. Bertaccini, T. Botti, R. Sisto, "Generation place of the long- and short-latency components of transient-evoked otoacoustic emissions in a nonlinear cochlear model", J. Acoust. Soc. Am. 133 (6), 98 48, (213). [21] D. D. Greenwood, "A cochlear frequency position function for severalspecies-29 years later", J. Acoust. Soc. Am. 87, 292-26, (199). [22] R. Sisto (1), A. M. Al-Maamury (2), A. Moleti (2), D. Bertaccini (2), T. Botti (3), "Emissioni Otoacustiche Transienti in Modelli non Lineari Della Coclea", 39 Convegno Nazionale AIA, Roma 4-6, (212). [23] R. Sisto, and A. Moleti, Transient evoked otoacoustic emission latency and cochlear tuning at different stimulus levels, J. Acoust. Soc. Am. 122, 2183 219, (27). [24] R. Sisto, Sanjust, F., and A. Moleti Input/output functions of different-latency components of transient-evoked and stimulus-frequency otoacoustic emissions, J. Acoust. Soc. Am. 133, 22 223, (213). [2] R. Sisto and A. Moleti, ''Objective Measurement of Cochlear Tuning FAC-TOR by Means of Time-Frequency Analysis of Oto-Acoustic Emissions,'' The 23rd International Congress on Sound and Vibration, ICSV23, Athens (Greece), -14 July (216).