2 CSN offers mechanical entilation, xygen, Cough, Suction, and Nebulizer therapies in one compact, portable, lightweight device. This Quick Start Guide is intended to provide a high-level overview of CSN use, and does not contain all the information required to operate CSN safely. For detailed instructions for use, see the Clinicial and Technical Manual, available online at enteclife.com. Critical Care entilator CSN brings next-generation technology, breathing comfort, and ease of use to ventilator patients. ENTILATIN xygen Concentrator capable of 6 L/min 2 The CSN internal oxygen concentrator and xygen Direct TM system deliver the equivalent of 6 L/min of oxygen. External oxygen sources can be connected when needed. XYGEN Touch Button Cough Touch Button Cough TM therapy can be activated in seconds, without changing the circuit. CUGH Hospital Grade Suction The quiet hospital-grade suction system is easy to transport. SUCTIN High Performance Nebulizer CSN compensates for nebulizer flow, records each medication use, and turns off the nebulizer when the therapy is complete. NEBULIZER

3 Table of Contents Quick Start Guide CSN Hardware verview CSN Software verview Night Mode and Day Mode Clinician Access Permissions Enable Prescribed Therapies Settings Buttons Exit Buttons Powering CSN CSN Placement Connecting a Patient Circuit Connecting and Removing a Bacterial Filter Mouthpiece Patient Circuits Active, Passive, and alveless entec ne-circuits Connecting a entec ne-circuit 2 Tube Connecting an Active entec ne-circuit Multilumen Tube The Pre-Use Test Changing entilation, xygen, or Cough Therapy Controls Setting entilation and xygen (Fi2) Alarms Responding to Alarms Connecting a Nurse Call System or Remote Alarm xygen Setup Connecting External xygen High-Pressure xygen Low-Pressure xygen Suction Therapy The CSN Suction Cap and Travel Suction Canister Suction Controls Nebulizer Therapy Connecting a Nebulizer Cup Nebulizer Controls CSN Therapy Interactions xygen Therapy Pauses with Nebulizer or Suction CSN Controls Setup enteclife.com 1

4 CSN Hardware verview Description 1 Touchscreen 13 Handle 2 Speaker 14 Cooling air outlet and Cough therapy exhaust 3 Alarm Silence button 15 High-pressure 2 input port 4 External Power / Charge Status indicator light 16 Low-pressure 2 input port 5 n/standby button and indicator light 17 Remote alarm or Nurse Call Cable port 6 Removable, rechargeable battery 18 USB ports for use by trained service technicians only. Do not use the CSN USB ports. 7 Active exhalation valve connection port 19 Cooling air intake and filter 8 entec ne-circuit 2 tube connection port 20 Power connection port 9 Nebulizer drive port 21 Patient air inlet and filter 10 External bacterial filter and entec ne-circuit connection port 22 Removable, rechargeable battery 11 Handle 23 Cooling air outlet 12 Cooling air outlet 24 Suction canister cap (protects and covers suction interface) 25 T-Slot mount 2 enteclife.com

5 CSN Software verview Link to Active and Recent Alarms Active Therapies Clinician Access Status Power Status Pressure Monitor Navigation Links Home Therapy Monitors Menu ENTILATIN XYGEN CUGH SUCTIN NEBULIZER Links to CSN Therapy Screens Night Mode and Day Mode You must use the Home screen to change between Night Mode and Day Mode. 1 Press NIGHT MDE to dim the LCD display. 2 Press DAY MDE for full screen brightness. Home 15BPM BREATH RATE Therapy 430mL TIDAL LUME Monitors Preset 1 ENT PRESET Menu NIGHT MDE NIGHT MDE DAY MDE enteclife.com 3

6 CUGH NEBULIZE N Clinician Access To lock or unlock CSN: 1 Press CLINICIAN ACCESS in the Menu tab. 2 Enter the four-digit Clinician Access passcode for the device, and then press ACCEPT. NTE: Each CSN has a unique Clinician Access passcode. The passcode is the last four digits of the device serial number. This number is printed on the CSN back label. It is also visible from the Service section of the MY CSN screen. To enable or disable the Clinician Access feature: Home PRE-USE TEST CLINICIAN ACCESS Therapy & ALARMS Monitors DEICE Menu LGS i MY CSN Home PRE-USE TEST CLINICIAN ACCESS Therapy & ALARMS Monitorsor Please enter Click passcode K to enter Clinician for clinician access Access mode. DEICEE Menu CANCEL 8 9 0LGS i ACCEPT MY CSN 1 Press DEICE in the Menu tab. Home Therapy Monitors Menu 2 Press edit, and then change the UNLCK REQUIRED? control to Yes or No. NTE: If the UNLCK REQUIRED? control is set to No, all CSN controls will be configurable by any CSN user. When set to Yes, controls set to Clinician nly in the PERMISSINS screen will be locked. See below for more details. PRE-USE TEST CLINICIAN ACCESS & ALARMS CUGH S ENABLE PRESCRIBED THERAPIES DEICE R X PERMISSINS LGS i MY CSN PRESCRIPTINS INSUFFLATIN TIME ALARM LUME PRESET DEICE seconds Medium DATE TIME 02:32 PM PRESET 2 CALIBRATE TUCHSCREEN UNLCK REQUIRED? Yes EDIT Permissions Using the Permissions feature, CSN can be locked so that a Clinician Access passcode is required to change some controls. To configure which controls are locked until a passcode is entered, first press PERMISSINS in the Menu tab. CIRCUIT TYPE MDE ENTILATR PERMISSINS CUGH PERMISSINS User and Clinician Clinician nly NEBULIZER PERMISSINS Then, use the toggles for each control group to configure whether the controls are accessible at all times (User and Clinician), and which require a Clinician Access passcode to modify (Clinician nly). HUMIDIFICATIN BREATH RATE INSPIRATRY TIME User and Clinician User and Clinician User and Clinician 4 enteclife.com

7 CUGH NEBULIZE N Enable Prescribed Therapies Press the ENABLE PRESCRIBED THERAPIES button to enable or disable CSN therapies such as the internal 2 Concentrator, Cough, Suction, Nebulizer, and/or the Fi 2 Monitor. This feature allows clinicians to enable a suite of therapies appropriate for the patient condition, and disable others. NTE: The Enable Prescribed Therapies menu button is only available when CSN is in Clinician Access mode. Home PRE-USE TEST CLINICIAN ACCESS Therapy & ALARMS CUGH S ENABLE PRESCRIBED THERAPIES Monitors DEICE R X PERMISSINS Menu LGS i MY CSN Settings Buttons When it appears, the (or & ALARMS) button will provide access to therapy configuration controls. Prepare patient circuit for Cough therapy, select preset, and press START to begin. LW -30 / +30 cmh2 Cough+Suction MEDIUM -35 / +35 cmh2 HIGH -40 / +40 cmh2 STP START THERAPY Exit Buttons CSN software has two types of buttons. Use these buttons to exit the current screen and navigate to other parts of the CSN software. Inside therapy screens, the button appears as a back arrow on the left-hand side of the screen. Prepare patient circuit for ventilation, select preset, and press START to begin. DAY NW ACTIE NIGHT AC-PRES MBILE SIM-PRES & ALARMS ACTIE START NW When navigating configuration screens, the button will appear as a tab in the upper left-hand corner. L H DAY MBILE NIGHT MDE PRESS T EDIT CIRCUIT TYPE TIDAL LUME Active 450 ml PRESS T EDIT BREATH RATE INSPIRATRY TIME PEEP SIGH 20 BPM 1.0 seconds 10 cmh20 FF EDIT enteclife.com 5

8 Powering CSN Whenever possible, connect CSN to an external source of continuous power. To connect the AC Adapter, plug the power supply into the power connection port in the back of CSN, and then plug the power supply into a power socket, such as a wall outlet. erify the external power indicator ( ) appears on the touchscreen. 1 2 CSN comes with two removable, rechargeable batteries, and one internal battery. Depending on your settings, these three batteries may power CSN for up to nine hours. The battery icons in the status bar show the power remaining in each removable battery (left and right side), and in the internal (center, upright) battery. A lightning bolt indicates the battery is charging. To remove a battery, lift the battery tab until it clicks out of place. Then, use the tab to gently pull the battery from the well from the top. 1 2 To install a battery, place the base of the battery into the well first, and then press the top of the battery into the well. Press the battery tab down until it clicks into place. The tab should be flat against the battery. 1 2 CSN Placement Do not block CSN air inlets and vents. Do not operate CSN on its back or on compliant bedding, which may obstruct the airflow around it. Do not cover CSN with towels or other materials. CSN should be placed in a well-ventilated area, free of airborne pollutants, contaminants, and fumes. ver time, direct sunlight may compromise the integrity of CSN plastic housing or the entec ne-circuit. Place CSN in a location that is not exposed to extended periods of direct sunlight, and ensure the environment is within the recommended range of temperature, altitude, and relative humidity for CSN. 6 enteclife.com

9 Connecting a Patient Circuit CSN may be connected to various circuit types available from entec Life Systems: a Mouthpiece, Active, Passive, or alveless entec ne-circuit. Connecting and Removing a Bacterial Filter To connect a filter fit it against CSN, aligning the tabs on the filter and CSN. Then, firmly twist the filter clockwise to lock it into place. 2 To remove a filter, firmly push in on the filter toward CSN and then twist it counterclockwise, aligning the tabs on the filter and CSN. Then, pull the filter to remove it. 1 Mouthpiece Patient Circuits Connect the Mouthpiece Circuit Kit components in the order depicted below. 1 Reducer cuff mm circuit tubing (one piece) 3 ptional Mouthpiece Circuit Support Arm, available separately 4 Coupler Flexible extension (optional) 6 Angled mouthpiece CSN enteclife.com 7

10 Active, Passive, and alveless entec ne-circuits Connect patient circuit components in the order depicted below. For additional information, see the CSN Clinical and Technical Manual, available online at enteclife.com. CSN CSN BACTERIAL FILTER HUMIDIFIER BYPASS (required for Cough) C (optional 2 tube) PATIENT CIRCUIT (optional heated wire) HME or HUMIDIFIER (choose one) NEBULIZER (optional) N SECRETIN TRAP (optional) C S PATIENT INTERFACE or Item Name Required? Additional Information CSN Bacterial Filter entec Humidifier Bypass Required Required for using Touch Button Cough therapy with a connected humidifier See Connecting and Removing a Bacterial Filter on page 7 for instructions. The entec Humidifier Bypass prevents water damage to CSN during Cough therapy. Humidifier ptional Include a form of humidification (either an HME or humidifier). Active, Passive, or alveless entec ne- Circuit Heat-Moisture Exchanger (HME) Required ptional Use either an active, passive, or valveless entec ne-circuit. entec ne-circuits may include an integrated 2 tube for xygen Direct therapy and/or a heated wire. Active entec ne- Circuits include flow sensor tubing. Include a form of humidification (either an HME or humidifier). Nebulizer ptional Connect a nebulizer to the nebulizer drive port. entec Secretion Trap ptional Connect a entec Secretion Trap, using suction tubing, to a suction canister. Patient Interface Required Examples of a patient interface include a mask or tracheal tube. entec ne-circuits include an exhalation valve and are intended for use with non-vented masks. 8 enteclife.com

11 Connecting a entec ne-circuit 2 Tube If your entec ne-circuit has an integrated 2 tube, connect the 2 tube to the oxygen output port on the right side of CSN. Fit the connection adapter around the port securely. ACTIE 2 NEBULIZER 6 L/min Connecting an Active entec ne-circuit Multilumen Tube Fit the oval connector tube into place in the Active connection port. Then, fit the connecting screw cap over the port and twist it clockwise until it is firmly secured. ACTIE 2 NEBULIZER 6 L/min enteclife.com 9

12 The Pre-Use Test To ensure therapy is delivered accurately, you must perform a Pre-Use Test whenever prompted, the patient circuit is changed, or the device is powered on. NTE: Though accuracy may be reduced, CSN may still be used to provide ventilation therapy without running the Pre-Use Test. If time constraints make running the test inadvisable, press the button to immediately initiate entilation therapy. The CSN Pre-Use Test calculates the resistance and leak of the entec ne-circuit. Based on these calculations, CSN verifies the integrity of the entec ne-circuit, and also improves the accuracy of therapy. If used, the Pre-Use Test will also verify the connection status of the entec ne-circuit 2 tube. NTE: If entilation therapy is critical to patient care, provide the patient with backup ventilation prior to initiating the Pre-Use Test. Some control changes cause CSN to prompt you to run a Pre-Use Test. You may also press the Menu tab and then the PRE-USE TEST button to begin a Pre-Use Test at any time. To run a Pre-Use Test, carefully follow the on-screen instructions. When instructed, use a clean, gloved hand to obstruct the circuit completely, as follows: PRE-USE TEST If you are using an Active or Passive entec ne-circuit, block it at the exhalation valve. If you are using alveless entec ne-circuit, disconnect the mask to run the test, and bypass this leak portion of the Pre-Use Test. Leak in the patient circuit will be calculated and compensated for during use. If you are using a mouthpiece patient circuit, leave the mouthpiece connected, and block the open end. If the test completes successfully, reconnect the entec ne-circuit to the patient and resume entilation therapy. If the test fails, inspect the entec ne-circuit configuration for leaks or improper setup. Resolve any issues with the entec ne-circuit, and then press RESTART to run the Pre-Use Test again. 10 enteclife.com

13 Changing entilation, xygen, or Cough Therapy Controls Press the Therapy tab, and then the entilation, Cough, or xygen icon, depending on which therapy you want to configure. 1 To configure a Preset, select it and then press the (or & ALARMS) button. NTE: Any of the three available Presets can be configured by pressing the Preset tabs along the top of the configuration screen. 2 Scroll to the control you want to modify, select it and then press the EDIT button on the right side of the blue selection bar. NTE: Note that the MDE, CIRCUIT TYPE, and LUME TARGETED ventilation controls cannot be modified while a Preset is active, and will appear in gray. If additional controls appear in gray, the Clinician Access passcode must be entered on the Menu screen before they can be modified. 3 Enter the new selection and then press ACCEPT to confirm the change. L H MDE CIRCUIT TYPE TIDAL LUME BREATH RATE INSPIRATRY TIME PEEP SIGH Prepare patient circuit for ventilation, select preset, and press START to begin. DAY NW ACTIE DAY Active 450 ml 20 BPM 1.0 seconds 10 cmh20 FF NIGHT AC-PRES NIGHT MBILE SIM-PRES ACTIE START NW MBILE PRESS T EDIT PRESS T EDIT & ALARMS L H MDE CIRCUIT TYPE TIDAL LUME BREATH RATE INSPIRATRY TIME PEEP SIGH L H DAY Active 450 ml 20 BPM 1.0 seconds 10 cmh20 FF NIGHT EDIT MBILE PRESS 5 T EDIT 6 PRESS T EDIT 7 CANCEL EDIT ACCEPT 4 When configuration is complete, press the tab along the top of the screen. MDE CIRCUIT TYPE TIDAL LUME BREATH RATE INSPIRATRY TIME Active 450 ml 20 BPM 1.0 seconds PRESS T EDIT PRESS T EDIT EDIT DAY NIGHT MBILE 5 Activate or switch between configured presets at any time by selecting the appropriate Preset and then pressing START. PEEP SIGH 10 cmh20 FF Prepare patient circuit for ventilation, select preset, and press START to begin. NTE: Use the Home or Monitors tab to view monitored information about the delivered entilation therapy. DAY NW ACTIE NIGHT AC-PRES MBILE SIM-PRES ACTIE START NW & ALARMS enteclife.com 11

14 Setting entilation and xygen (Fi 2 ) Alarms For a description of all available alarms and their settings, see the Clinical and Technical Manual, available online at enteclife.com. 1 To configure a Preset s alarms, press the & ALARMS button. Prepare patient circuit for ventilation, select preset, and press START to begin. 2 Alarms are configured like controls, using the EDIT button in the blue bar. DAY NW ACTIE NIGHT AC-PRES MBILE SIM-PRES ACTIE START NW & ALARMS 3 If the alarm includes a Low and High setting, select the L icon to adjust the Low alarm setting. Press the H icon to adjust the High alarm setting. FF N PRESET 1 PRESET 2 CIRCUIT DISCNNECT APNEA PEAK INSP. PRESSURE TIDAL LUME N 30 seconds 3 cmh2 300 ml 17 cmh2 900 ml H PRESS 5 T EDIT 6 PRESS T EDIT HL 0 L CANCEL ACCEPT 4 If necessary, use the N/FF toggle to turn the alarm N. Then use the keypad to enter the desired setting. MINUTE ENTILATIN 6 L/min 9 L/min FF N PRESET 1 PRESET 2 CIRCUIT DISCNNECT APNEA PEAK INSP. PRESSURE N 30 seconds 3 cmh2 17 cmh PRESS 5 T EDIT 6 PRESS T EDIT TIDAL LUME 300 ml H 900 ml HL 0 L CANCEL ACCEPT 5 Press ACCEPT to confirm the new alarm settings. NTE: The High Pressure Delay and Patient Circuit Disconnect alarm settings can be used to help reduce nuisance alarms. MINUTE ENTILATIN 6 L/min 9 L/min FF N PRESET 1 PRESET 2 CIRCUIT DISCNNECT APNEA PEAK INSP. PRESSURE TIDAL LUME N 30 seconds 3 cmh2 300 ml H 17 cmh2 900 ml L MINUTE ENTILATIN 6 L/min 9 L/min PRESS 5 T EDIT 6 PRESS T EDIT HL 0 CANCEL ACCEPT 12 enteclife.com

15 Responding to Alarms To view the CSN Alarm Log, press the alarm banner in the status bar, or press the Menu tab, and then the LGS button. The most recent alarms are listed at the top of the page. Active alarms will appear with a red (high-priority), yellow (medium-priority), or blue (low-priority) banner. To clear the list of all but the active alarm conditions, press the CLEAR LIST button from the Alarm Log screen. Information about the alarm will also be stored in the CSN Event Log, which cannot be deleted. To inactivate and reactivate alarm signals, use the Alarm Silence button on the front of CSN. LGS Connecting a Nurse Call System or Remote Alarm The remote alarm port is behind a protective rubber flap on the back of CSN. This port may be used to connect a remote alarm, a nurse call system, or other alarm systems that sense contact closure through a 1/4 phono jack. nly use the remote alarm port with entec Nurse Call cables or other cables approved by entec Life Systems. Follow all setup instructions provided by the remote alarm or nurse call system manufacturer. Always test the alarm immediately after installation, and periodically during use to ensure it is functioning as intended. enteclife.com 13

16 xygen Setup xygen Direct therapy may be delivered from the internal 2 Concentrator in Pulse Dose mode (through an integrated oxygen tube inside the patient circuit). The internal 2 Concentrator will deliver the equivalent of up to 6 L/min of oxygen without connecting an external oxygen source. With external high-pressure oxygen connected, xygen therapy may be delivered as either a Pulse Dose or Fi 2. Additive low-pressure oxygen may also be used. Connecting External xygen High-Pressure xygen External high-pressure oxygen sources can be connected to CSN to provide xygen therapy in either Pulse Dose or Fi 2 mode. Low-Pressure xygen External low-pressure oxygen sources can be connected to CSN to add oxygen into the entec ne- Circuit. xygen from a lowpressure oxygen source is additive, and can be used in conjunction with oxygen from the internal 2 concentrator or an external high-pressure source. The flow of low-pressure oxygen is controlled by the oxygen source, not by the CSN oxygen controls. 14 enteclife.com

17 Suction Therapy The CSN Suction Cap and Travel Suction Canister The entec Travel Suction Canister has a 300 ml capacity. If the canister fills above the 300 ml line on the canister (just below the blue knob), a hydrophobic filter will activate. This filter stops Suction therapy and prevents liquids from entering CSN. Unlock and lock the CSN Suction Cap by twisting the cap. Lock and unlock the entec Travel Suction Canister by twisting the blue knob. The lock and unlock knob positions are printed on the front of the cap and canister. The canister knob must be in the unlock position to reattach the canister to CSN. nce reattached, twist the knob to the Lock position to secure the canister in place. CSN Connect 1/4 suction tubing by fitting its connector firmly over the suction connection port in the top of the canister. Then, connect the other end of the tubing to a suction interface, such as an open-suction catheter (shown below), a entec Secretion Trap, or a closed-suction catheter in the patient circuit. To empty the canister, disconnect it (by twisting the knob to the Unlock position). nce away from CSN, twist the knob coutnerclockwise to the dot position to pull the knob out of the canister and empty its contents. Lock to Suction Unlock to Connect and Remove Remove Knob to Empty CSN enteclife.com 15

18 Suction Controls NTE: xygen therapy is paused during Suction therapy. See CSN Therapy Interactions on page 18 for more information. Press the Therapy tab, and then the Suction icon. Use the + and - buttons to adjust the ACUUM control. Whenever the Suction therapy screen is accessed, or the Cough + Suction feature is activated, the ACUUM control will reset to its default setting. To adjust the Suction therapy default, adjust the ACUUM control using the + and - buttons, and then press the SET DEFAULT button at the desired default setting ACUUM mmhg 4 0 inhg 50 0 mmhg SET DEFAULT STP START THERAPY When the control is set appropriately to provide Suction therapy to the patient, press the START button to begin therapy. erify there are no leaks and that Suction therapy is functioning as intended by occluding the suction tubing or attached catheter with a clean, gloved hand. bserve the suction monitor (indicated by the solid fill inside the arc) and verify it matches the set vacuum value (displayed as a numeric value inside the arc, and a black line). NTE: nce the START button is pressed, Suction therapy may take up to 5 seconds to begin. 16 enteclife.com

19 Nebulizer Therapy NTE: xygen therapy is paused during Nebulizer therapy. See CSN Therapy Interactions on page 18 for more information. Connecting a Nebulizer Cup To connect a nebulizer cup to CSN, install the nebulizer cup between the exhalation valve and patient interface. If an HME is used, connect the nebulizer cup between it and the patient to prevent the HME from trapping nebulized material. Then, connect the nebulizer cup tubing to the CSN nebulizer drive port (the right-most port). entec ne-circuit HME (optional) Nebulizer Cup 1 CSN ACTIE 2 NEBULIZER 6 L/min 2 Nebulizer Controls Press the Therapy tab, and then the Nebulizer icon. CSN Nebulizer therapy will run for the set nebulizer duration, and then stop automatically. Use the + and - buttons on the MINUTES control to set the desired duration. To begin therapy, press the START button. Nebulizer therapy may be stopped any time using the STP THERAPY button NEBULIZER DURATIN N mins STP THERAPY MINUTES 15MIN NEBULIZER MINUTES REMAINING enteclife.com 17

20 CSN Therapy Interactions nly one of the following therapies can be delivered at a time: xygen, Suction, or Nebulizer. The following table describes how starting a therapy affects other CSN therapies: NTE: It may take up to 5 seconds for a therapy to begin after pressing the START button. Home Therapy Monitors Menu Effect of Starting Another Therapy: START ENTILATIN XYGEN CUGH SUCTIN NEBULIZER Running Therapy: xygen (Pulse Dose) xygen (Fi2) xygen (Ext. Low- Pressure) Cough Suction Nebulizer entilation Paused (automatically resumes) xygen (Pulse Dose) N/A Ended Paused (automatically resumes) Paused (automatically resumes) Paused (automatically resumes) xygen (Fi2) Ended N/A Paused (automatically resumes) Paused (automatically resumes) xygen (Ext. Low- Pressure) Controlled by xygen Source N/A C Cough N/A N/A N/A with Cough + Suction feature N/A S Suction Ended Ended N/A Ended N Nebulizer Ended Ended Paused (automatically resumes) Ended N/A xygen Therapy Pauses with Nebulizer or Suction Because xygen is paused during Nebulizer and Suction therapies, the following approaches may be used to maintain patient oxygenation, if it is critical to patient care: Use an external nebulizer or suction machine to provide the therapy. When using an external nebulizer, this approach may require setting the High Minute olume alarm higher for the duration of the treatment. Use an external source of low-pressure oxygen during Nebulizer or Suction therapy. Low-pressure oxygen flowing through CSN and into the patient circuit is not controlled by CSN xygen therapy settings and is additive. An external low-pressure oxygen source may be used for the duration of CSN Nebulizer or Suction therapy to maintain adequate patient oxygenation. 18 enteclife.com

21 CSN Controls Setup entilation Control Preset Label Mode Patient Type (Adult or Pediatric Circuit) Humidification (Humidifier or HME) Circuit Type (Active, Passive, or Mouthpiece) Breath Rate (or Backup Rate) Inspiratory Time olume Targeted (n or ff) Tidal olume Flow Trigger Pressure Control entilation Setting entilation entilation Alarm Setting Preset 1 Preset 2 Preset 3 Alarm Preset 1 Preset 2 Preset 2 Preset Label Apnea Alarm Low Breath Rate Alarm High Breath Rate Alarm Low Minute olume Alarm High Minute olume Alarm Low Inspiratory Pressure Alarm High Inspiratory Pressure Alarm High PEEP Alarm Low PEEP Alarm Patient Circuit Disconnect Alarm Delay Pressure Support High Pressure Delay IPAP Cough Cough Setting PEEP or EPAP Control Preset 1 Preset 2 Preset 3 PC Flow Termination Preset Label Flow Cycle Insufflation Pressure Time Cycle Rise Time Leak Compensation Sigh Apnea Rate xygen Controls and Alarms Preset Label xygen Source xygen therapy (in L/min or Fi2) Low Fi2 Alarm High Fi2 Alarm xygen Settings Exsufflation Pressure Insufflation Time Exsufflation Time Pause Time Insufflation Rise Time Cough Cycles Preset 1 Preset 2 Preset 3 Breath Sync Cough + Suction Suction and Nebulizer Controls Suction (acuum in mmhg) Nebulizer (Duration) Suction and Nebulizer Settings enteclife.com 19

22 About entec Life Systems entec Life Systems is redefining respiratory care to improve patient outcomes and reduce caregiver challenges in the hospital and home. entec s leading product, CSN, seamlessly integrates five separate devices including a ventilator, oxygen concentrator, cough assist, suction, and nebulizer into one unified respiratory system. The team s history of patientcentric design brings care changing innovations to life for patients, medical professionals, and caregivers. For questions about CSN: enteclife.com info@venteclife.com MY-CSN enteclife.com LBL Rev B Copyright 2017, entec Life Systems Caution: U.S. Federal law restricts this device to sale by or on the order of a physician.

Provider guide. DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP

Provider guide. DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP Provider guide DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP IMPORTANT! Remove this guide before giving the device to the patient. Only medical

More information

Provider guide. DreamStation

Provider guide. DreamStation Provider guide DreamStation CPAP CPAP Pro Auto CPAP BiPAP Pro Auto BiPAP IMPORTANT! Remove this guide before giving the device to the patient. Only medical professionals should adjust pressure settings.

More information

My CoughAssist. A patient guide to CoughAssist E70

My CoughAssist. A patient guide to CoughAssist E70 My CoughAssist A patient guide to CoughAssist E70 A natural part of life Coughing. We often think of a cough as a symptom of a cold or a means to clear our throat. Truth is, the ability to cough is essential

More information

DreamStation. Provider guide

DreamStation. Provider guide Provider guide Accessing the Provider mode screens Accessing Provider mode unlocks settings that cannot be modified by the user. To access Provider mode: 1. ce the device is powered, press and hold both

More information

Introducing Infant Flow Advance SIPAP. By Joanne Cookson March 2008

Introducing Infant Flow Advance SIPAP. By Joanne Cookson March 2008 Introducing Infant Flow Advance SIPAP By Joanne Cookson March 2008 Aim To introduce clinical practioners to the new SiPAP machine Objectives To define what is SiPAP To look at different modes able to be

More information

TO THE OPERATOR AND PERSON IN CHARGE OF MAINTENANCE AND CARE OF THE UNIT:

TO THE OPERATOR AND PERSON IN CHARGE OF MAINTENANCE AND CARE OF THE UNIT: fabian HFO Quick guide TO THE OPERATOR AND PERSON IN CHARGE OF MAINTENANCE AND CARE OF THE UNIT: This Quick Guide is not a substitute for the Operation Manual. Read the Operation Manual carefully before

More information

BiPAP Pro Bi-Flex. Accessing the Provider Mode Screens PROVIDER GUIDE

BiPAP Pro Bi-Flex. Accessing the Provider Mode Screens PROVIDER GUIDE BiPAP Pro Bi-Flex PROVIDER GUIDE IMPORTANT! Remove this guide before giving the device to the patient. Only medical professionals should adjust pressure settings. This guide provides you with instructions

More information

RELEASED. first steps. Icon Icon name What it means

RELEASED. first steps. Icon Icon name What it means Icon Icon name What it means Connection The connection icon appears green when the Sensor feature is on and your transmitter is successfully communicating with your pump. The connection icon appears gray

More information

Bringing Advanced Technology to Airway Clearance

Bringing Advanced Technology to Airway Clearance Bringing Advanced Technology to Airway Clearance NIPPY Clearway Sales Training - Objectives Overview of MRD specification Introduction to the device Understanding the modes Key Messaging Questions Overview

More information

Evolve 3 & 5 Service Manual

Evolve 3 & 5 Service Manual Evolve 3 & 5 Service Manual 1 Product Browse 2 Contents CHAPTER 1: SERIAL NUMBER LOCATION... 5 CHAPTER 2: CONSOLE INSTRUCTIONS 2.1 Console Overview... 6 2.1.1 Evolve 3 Console Overview... 6 2.1.2 Evolve

More information

Sleep Apnea Therapy Software Clinician Manual

Sleep Apnea Therapy Software Clinician Manual Sleep Apnea Therapy Software Clinician Manual Page ii Sleep Apnea Therapy Software Clinician Manual Notices Revised Notice Trademark Copyright Sleep Apnea Therapy Software Clinician Manual 103391 Rev A

More information

RaySafe i3 INSTALLATION & SERVICE MANUAL

RaySafe i3 INSTALLATION & SERVICE MANUAL RaySafe i3 INSTALLATION & SERVICE MANUAL 2017.06 Unfors RaySafe 5001104-1.1 All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical

More information

Cough Assist. Information for patients, families and carers Therapy Services

Cough Assist. Information for patients, families and carers Therapy Services Cough Assist Information for patients, families and carers Therapy Services PROUD TO MAKE A DIFFERENCE SHEFFIELD TEACHING HOSPITALS NHS FOUNDATION TRUST page 2 of 16 Table of contents Why do I need a Cough

More information

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I PORTO 2 VENT CPAP OS Operator s Manual 1 2 TABLE of CONTENTS 1. Introduction 3. Operating Instructions 1a. Definitions 3a. Setting the CPAP Level 1b. General Description 3b. Applying the Breathing Circuit

More information

HealthCare International, Inc. PO Box 1509, Langley, WA P: (360) or (800)

HealthCare International, Inc. PO Box 1509, Langley, WA P: (360) or (800) Owner s Manual V2.2 HealthCare International, Inc. PO Box 1509, Langley, WA 98260 www.hcifitness.com sales@hcifitness.com P: (360) 321-7090 or (800) 398-9121 1 Table of Contents Safety Precautions... 3

More information

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS 3K NON-INVASIVE POSITIVE PRESSURE VENTILATION (NIPPV) ADULT EMT EMT-INTERMEDIATE 85 ADVANCED EMT PARAMEDIC Indications: 1. Dyspnea Uncertain Etiology Adult. 2. Dyspnea Asthma Adult. 3. Dyspnea Chronic

More information

Portable Equine Nebuliser System. User Manual

Portable Equine Nebuliser System. User Manual Portable Equine Nebuliser System User Manual Table of Contents INTENDED USE... 3 SAFETY INFORMATION... 3 TECHNICAL SPECIFICATION... 4 INSTRUCTIONS FOR USE... 6 MAINTENANCE... 12 TROUBLESHOOTING... 13 WARRANTY...

More information

Effective Date: August 31, 2006 SUBJECT: CARE AND USE OF NEBULIZER AND INTERMITTENT POSITIVE PRESSURE BREATHING DEVICE

Effective Date: August 31, 2006 SUBJECT: CARE AND USE OF NEBULIZER AND INTERMITTENT POSITIVE PRESSURE BREATHING DEVICE COALINGA STATE HOSPITAL NURSING POLICY AND PROCEDURE MANUAL SECTION - Treatments POLICY NUMBER: 421 Effective Date: August 31, 2006 SUBJECT: CARE AND USE OF NEBULIZER AND INTERMITTENT POSITIVE PRESSURE

More information

BLINDED MODE USERS GUIDE SUPPLEMENT

BLINDED MODE USERS GUIDE SUPPLEMENT BLINDED MODE USERS GUIDE SUPPLEMENT BLINDED MODE user s guide SUPPLEMENT WARNING: The SEVEN PLUS when set to Blinded Mode using the Data Manager Software will not provide real-time continuous glucose readings,

More information

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port AVTECH Mini UPS and Power Sensor AVTECH s Mini UPS and Power Sensor (MUPS) monitors the on/off state of a power source, such as main power, a UPS, surge protector or standard wall outlet, and also provides

More information

Sept ibreeze+ Series. Redefine your premium CPAP

Sept ibreeze+ Series. Redefine your premium CPAP Sept. 2018 Series Redefine your premium CPAP Redefine premium CPAP Portable Comfortable Intuitive Performing A compact artwork Connection premium PAP system is one of the smallest PAP solutions in the

More information

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients. EN WILAflow Elite Neonatal Ventilator Non-invasive treatment for the most delicate patients. 0197 Infant Ventilation redefined A new generation in Infant Ventilation WILAflow Elite is a microprocessor

More information

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients. EN WILAflow Elite Neonatal Ventilator Non-invasive treatment for the most delicate patients. 0197 Infant Ventilation redefined A new generation in Infant Ventilation WILAflow Elite is a microprocessor

More information

TIP CARD. Model Temporary External Pacemaker

TIP CARD. Model Temporary External Pacemaker TIP CARD Model 5392 Temporary External Pacemaker PRE-USE What to do... What NOT to do... Battery Replace the battery for each new patient. Do NOT reuse battery. Physical Check case for cracks/damage.**

More information

Drivers have GPS. Dialysis Patients have. Making possible personal.

Drivers have GPS. Dialysis Patients have. Making possible personal. Drivers have GPS Dialysis Patients have with The Amia System with Sharesource Connectivity Platform. For step-by-step navigation of home peritoneal dialysis. Please see indications for use on the back

More information

Complex Care Hub Manual: Continuous Positive Airway Pressure (CPAP) Ventilation

Complex Care Hub Manual: Continuous Positive Airway Pressure (CPAP) Ventilation Complex Care Hub Manual: Continuous Positive Airway Pressure (CPAP) Ventilation Table of Contents 1. What is Continuous Positive Airway Pressure (CPAP)?... 2 2. Important information for support worker...

More information

User Manual Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW

User Manual Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW User Manual 2010 Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW Home Phone Connect Welcome to Verizon Wireless Thank you for choosing Verizon Wireless Home Phone Connect. You re now

More information

Graphical User Interface for Windows for MCM Module

Graphical User Interface for Windows for MCM Module Page 1 of 8 Installation:- Please ensure that you have the latest updated GUI and download the GUIv.x.x.x.x.ZIP from our website. Extract the folder to a temporary location (These files can be deleted

More information

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler Breezhaler 3 Pull cap off Press buttons once and release Breathe in rapidly and steadily. Hold. Open. Place capsule in chamber. Close (click). Breathe out 4 Open to see clear capsule. If not all clear

More information

Cough assist T70 for the Tracheostomy Child

Cough assist T70 for the Tracheostomy Child Patient and Family Education Cough assist 70 for the racheostomy Child with or without a ventilator What is a Cough assist device? he Cough assist 70 device removes mucus (secretions) from your child s

More information

GLOOKO FOR ios MIDS USER GUIDE

GLOOKO FOR ios MIDS USER GUIDE GLOOKO FOR ios MIDS USER GUIDE October 2018 IFU-0001 13 Glooko MIDS is cleared for US only Rx only TABLE OF CONTENTS TABLE OF CONTENTS MOBILE INSULIN DOSING SYSTEM (MIDS)... 2 Intended Use... 2 Warnings...

More information

CoughAssist E70. More than just a comfortable cough. Flexible therapy that brings more comfort to your patients airway clearance

CoughAssist E70. More than just a comfortable cough. Flexible therapy that brings more comfort to your patients airway clearance CoughAssist E70 More than just a comfortable cough Flexible therapy that brings more comfort to your patients airway clearance Flexible, customisable loosening and clearing therapy An effective cough is

More information

HealthCare International, Inc.

HealthCare International, Inc. Owner s Manual V.2 HealthCare International, Inc. 1 Table of Contents Safety Precautions... 3 Warranty Information... 4 Assembly Instructions... 5 Quick Tips... 8 AC Adaptor:... 8 Levelers:... 8 Seat Adjustments:...

More information

I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device

I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device II. Policy: Continuous Positive Airway Pressure CPAP by the Down's system will be instituted by Respiratory Therapy personnel

More information

N4i Installation Manual. (picture of N4i screen)

N4i Installation Manual. (picture of N4i screen) N4i Installation Manual (picture of N4i screen) 1 Table of Contents N4i Computer Parts List... 4 Netpulse Stabilizer Bar Parts List... 6 Hardware List... 7 Tools Needed for Installation... 7 N4i Assembly

More information

Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG)

Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG) Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG) Get Your Cardio On Preparations for this experiment need to be reviewed with the students in advance. There will be exercise routines

More information

Epilepsy Sensor Transmitter

Epilepsy Sensor Transmitter Epilepsy Sensor Transmitter Installation Guide t: 01977 661234 f: 01977 660562 e: enquiries@tunstall.com w: uk.tunstall.com Version: V0.1 (421V0R1.18) Contents 1. Features and Introduction... 3 Your Epilepsy

More information

KOALA. Adult Bacterial Viral Filters. Medical Pty Ltd

KOALA. Adult Bacterial Viral Filters. Medical Pty Ltd Specialising in Anaesthetic Devices & Airway Management Laproscopic Surgery Maternity & Infant Care Adult Bacterial Viral Filters High efficiency up to 99.9 % @ 30L/Min Low resistance < 2.5 cmh2o @ 50

More information

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being Natural performance Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being Because our innovations are inspired by you and your patients, the bi-level ventilator

More information

Carina. The compact wonder. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Carina. The compact wonder. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Carina The compact wonder Emergency Care Perioperative Care Critical Care Perinatal Care Home Care The new sub-acute ventilator Carina Sub-acute care is a rapidly growing medical care service for patients

More information

Dosimeter Setting Device

Dosimeter Setting Device Instruction Manual Dosimeter Setting Device For Electronic Personal Dosimeter Dose-i (Unit:Sv, Version:1.05 English) WTA529748 a 1 / 38 Foreword Thank you for purchasing the Dosimeter Setting Device; a

More information

Sleep Apnea Therapy Software User Manual

Sleep Apnea Therapy Software User Manual Sleep Apnea Therapy Software User Manual Page ii Notices Revised Notice Trademark Copyright 103392 Rev B Published February 8, 2013 and supersedes all previous versions. The information contained in this

More information

Nord.cTracICA.Cr USER'S MANUAL A CAUTION QUESTIONS? .. Visit our website'at. new products, prizes, fitness tips, and much more!

Nord.cTracICA.Cr USER'S MANUAL A CAUTION QUESTIONS? .. Visit our website'at. new products, prizes, fitness tips, and much more! Nord.cTracICA.Cr Model No. NTCW90907.1 Serial No. Write the serial number in the space above for reference. _ USER'S MANUAL Serial Number Decal (under frame) QUESTIONS? As a manufacturer, we are committed

More information

Table of Contents. Contour Diabetes App User Guide

Table of Contents. Contour Diabetes App User Guide Table of Contents Introduction... 3 About the CONTOUR Diabetes App... 3 System and Device Requirements... 3 Intended Use... 3 Getting Started... 3 Downloading CONTOUR... 3 Apple... 3 Android... 4 Quick

More information

Aerobic Lateral Trainer

Aerobic Lateral Trainer Aerobic Lateral Trainer Assembly Manual HLT2500 IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THIS OWNER S MANUAL CONTAINS ASSEMBLY, OPERATION, MAINTENANCE AND SAFETY INFORMATION. IN

More information

1.40 Prevention of Nosocomial Pneumonia

1.40 Prevention of Nosocomial Pneumonia 1.40 Prevention of Nosocomial Pneumonia Purpose Audience Policy Statement: The guideline is designed to reduce the incidence of pneumonia and other acute lower respiratory tract infections. All UTMB healthcare

More information

How to Set Up and Infuse Your TPN

How to Set Up and Infuse Your TPN Page 1 of 10 How to Set Up and Infuse Your TPN Important: Do not change any of the supplies listed here. Keep supplies away from children. Only your home care nurse or persons trained by Fairview Home

More information

Vital Signs Monitor Series (VSM) Outline Train the Trainer

Vital Signs Monitor Series (VSM) Outline Train the Trainer Vital Signs Monitor 52000 Series (VSM) Outline Train the Trainer A. Light Weight and Durable 1. Weighs approximately 6 pounds 2. Made of heavy plastic B. Battery 1. Sealed lead acid battery 6 V 2. Battery

More information

Beltone Solus Pro 1.9 Fitting Guide

Beltone Solus Pro 1.9 Fitting Guide Beltone Solus Pro 1.9 Fitting Guide Table of Contents Table of Contents... 2 Getting started... 3 Start Screen... 3 Assigning Devices... 4 Connection Process... 5 MSG Calibration... 5 Gain Adjustment...

More information

TECHNOCARE MEDISYSTEMS

TECHNOCARE MEDISYSTEMS TECHNOCARE MEDISYSTEMS TM 109 Patient Monitor Essential Monitoring Special Care Just what you ordered. A monitoring solution to support any care decision. For any care environment, National Medical delivers

More information

Compressor Nebulizer. Guidebook

Compressor Nebulizer. Guidebook NSTRU Compressor Nebulizer Guidebook MODEL: MQ6002 READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE Compressor Nebulizer MODEL NO: MQ6002 INSTRUCTIONS INDEX 1. Introduction ----------------------------------------------------------------

More information

User Manual. RaySafe i2 dose viewer

User Manual. RaySafe i2 dose viewer User Manual RaySafe i2 dose viewer 2012.03 Unfors RaySafe 5001048-A All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical or otherwise,

More information

experiences that matter

experiences that matter Salter Labs Product Catalog Aerosol Delivery Products International 2015 Distinct products experiences that matter International 2015 Aerosol delivery NebuTech Nebulisers...B2 T-Piece Nebulisers...B5

More information

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors VITAL SIGNS MONITORING RVS-100/200 ri-vital Vital Signs Patient Monitors RVS-100 ADVANCED VITAL SIGNS MONITOR The RVS-100 is an advanced vital signs monitor which offers pulse oximetry, blood pressure

More information

English. Fealite Nasal Pillows System. User Manual

English. Fealite Nasal Pillows System. User Manual Fealite Nasal Pillows System User Manual 0123 Table of Contents Fealite Nasal Pillows System 1 Intended Use 1 Medical Information 1 Parts of the Fealite 3 Fitting the Fealite 5 Using Tube Retainer (Optional)

More information

GETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING

GETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING GETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING Contents Continuous Glucose Monitoring Getting started with continuous glucose monitoring Section 1: Section 2: Section 3: Section 4: Section

More information

PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606

PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606 PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606 Please read this guidebook carefully before operating this unit. Your Nebulizer is intended for use in the treatment of asthma, COPD and

More information

IMPORTANT: Please read and follow all instructions thoroughly before using your AB SHREDDER. Maximum user weight is 100 KG. KEEP BODY PARTS, HANDS AND FEET AWAY FROM THE SEAT, WHEELS AND THE CURVED TRACK

More information

Respironics C Flex Manual File Type

Respironics C Flex Manual File Type We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with respironics c flex manual

More information

Contour Diabetes app User Guide

Contour Diabetes app User Guide Contour Diabetes app User Guide Contents iii Contents Chapter 1: Introduction...5 About the CONTOUR DIABETES app...6 System and Device Requirements...6 Intended Use...6 Chapter 2: Getting Started...7

More information

Positive Pressure Therapy

Positive Pressure Therapy Positive Pressure Therapy Positive Pressure Therapy...2 What is Sleep Apnea?....2 Positive Pressure Machines..................................................... 4 Types..................................................................................

More information

SP850 OWNER S MANUAL

SP850 OWNER S MANUAL SP850 OWNER S MANUAL Product may vary slightly from the item pictured due to model upgrades Read all instructions carefully before using this product. Retain this owner s manual for future reference. NOTE:

More information

Nitelog. User Manual. For use with the Z1 Auto CPAP System

Nitelog. User Manual. For use with the Z1 Auto CPAP System Nitelog User Manual For use with the Z1 Auto CPAP System Thank you for choosing the Z1 Auto TM CPAP System from Human Design Medical, LLC. This Nitelog User Manual provides information as to how to use

More information

TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL

TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL IMPORTANT: Read all instructions carefully before using this product. Retain owner s manual for future reference. For customer service, please contact:

More information

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel: OWNER S MANUAL BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio 43035 Tel: 800.990.5556 1 www.bodycraft.com SAFETY INSTRUCTION WARNING: To reduce the risk of serious injury, read the following safety

More information

XT series. Continuous Positive Airway Pressure

XT series. Continuous Positive Airway Pressure XT series Continuous Positive Airway Pressure XT series is one of the smallest CPAP in the market. Its palmsized and light weight design lends itself well to travel. However, it delivers the same effective

More information

CROSS TRAINING MAGNETIC TREADMILL

CROSS TRAINING MAGNETIC TREADMILL CROSS TRAINING MAGNETIC TREADMILL SF-T7615 USER MANUAL IMPORTANT : Read all instructions carefully before using this product. Retain this manual for future reference. For customer service, contact support@sunnyhealthfitness.com

More information

SDS 4.0 Tips and Tricks

SDS 4.0 Tips and Tricks SDS 4.0 Tips and Tricks Content Important information 3 SDS 4.0 Fit and Go Box overview 4 Selecting the receiver length 5 Choosing the correct earpiece for the receiver 6 Attaching / removing the retention

More information

Instruction Manual Wellness Coach - Sleep

Instruction Manual Wellness Coach - Sleep Instruction Manual Wellness Coach - Sleep V1.4 JUNE 2018 TABLE OF CONTENTS INSTALL THE MOBILE APP WELLNESS COACH SLEEP...4 LOGIN TO WELLNESS COACH SLEEP...5 Login with a Wellness Coach Health account...5

More information

TWISTING STAIR STEPPER WITH BANDS

TWISTING STAIR STEPPER WITH BANDS TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL IMPORTANT! Please retain owner s manual for maintenance and adjustment instructions. Your satisfaction is very important to us, PLEASE DO NOT RETURN

More information

Resting and Stress ECG

Resting and Stress ECG Operating Manual Resting and Stress ECG 1 Safety 2 Hardware 3 Software 4 Hygiene Part 3: Operating characteristics: custo diagnostic 5.0 and higher for Windows MSW 0001 DK 1660 Version 002 13/06/2018 2018

More information

Rhino Clear Sprint Atomizer

Rhino Clear Sprint Atomizer Visit us online to view our wide range of sinus therapy medications for use with the Rhino Clear Sprint atomizer. www.woodlandhillspharmacy.com 20631 Ventura Blvd, Ste 305 Woodland Hills, CA 91364 Phone:

More information

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE A-dec 37L or 57L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE Contents Before You Begin.......... Remove the Covers........ Choose the Procedure...... 3 Install the Rigid Arm.......

More information

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe E L L I P T I C A L T O T A L B O D O W N E R S M A N U A L TABLE OF CONTENTS 1.0 IMPORTANT SAFET INSTRUCTIONS Read and save these instructions Setting up the Elliptical total body 1.1 Installation requirements

More information

SelectTech 3.1 Bench Assembly / Owner s Manual

SelectTech 3.1 Bench Assembly / Owner s Manual SelectTech 3.1 Bench Assembly / Owner s Manual This product is compliant with the applicable CE requirements. Congratulations on your commitment to fitness and your purchase of the Bowflex SelectTech 3.1

More information

TruLink Hearing Control App User Guide

TruLink Hearing Control App User Guide TruLink Hearing Control App User Guide GET CONNECTED In order to use TruLink Hearing Control app, you must first pair your hearing aids with your ios device. IMPORTANT: Before completing the following

More information

AFCH NEUROMUSCULAR DISORDERS (NMD) PROTOCOL

AFCH NEUROMUSCULAR DISORDERS (NMD) PROTOCOL AFCH NEUROMUSCULAR DISORDERS (NMD) PROTOCOL A. Definition of Therapy: 1. Cough machine: 4 sets of 5 breaths with a goal of I:E pressures approximately the same of 30-40. Inhale time = 1 second, exhale

More information

Lumis Tx: the all-in-one hospital ventilation solution

Lumis Tx: the all-in-one hospital ventilation solution Lumis Tx: the all-in-one hospital ventilation solution The Lumis Tx is a multi-purpose non-invasive ventilator that treats the full range of respiratory conditions and is suitable for a variety of hospital

More information

This letter is to notify you of recent changes to the PULMOZYME product monograph. Please note, additions/changes have been highlighted in yellow.

This letter is to notify you of recent changes to the PULMOZYME product monograph. Please note, additions/changes have been highlighted in yellow. April 9, 2015 Subject: Revised Product Monograph - PULMOZYME (dornase alfa) Dear Drug Information / Poison Control Centres, This letter is to notify you of recent changes to the PULMOZYME product monograph.

More information

For Electric Personal Dosimete Dose-i

For Electric Personal Dosimete Dose-i Instruction Manual Dosime eter Setting Device For Electric Personal Dosimete er Dose-i (Unit:rem, Version:1.05 English) Issued on March 2015 WTA529893 1 / 38 Foreword Thank you for purchasing the Dosimeter

More information

MiniMed 640G System Intelligent for Better Control

MiniMed 640G System Intelligent for Better Control Getting Started with the MiniMed 640G System Intelligent for Better Control Table Of Contents Introduction I MiniMed Care Introducing the MiniMed 640G System MiniMed Care...3 Welcome...4 The Delivery of

More information

Clearway Cough Assistor for Home Use

Clearway Cough Assistor for Home Use Clearway Cough Assistor for Home Use Physiotherapy Department Lower Lane Liverpool L9 7AL Tel:0151-525-5980 What is a Cough Assistor? The Cough Assistor is a machine which can help you clear secretions

More information

The Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older ***

The Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** The Phalanx Featuring Evolv DNA250 Technology ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** Congratulations on your purchase of the Phalanx DNA250 temperature protected

More information

Motorised Treadmill Model No: JI1625

Motorised Treadmill Model No: JI1625 BODYWORX Motorised Treadmill Model No: JI1625 Retain this owner s manual for future reference Read and follow all instructions in this owner s manual Version A 1 TABLE OF CONTENTS OVERVIEW DRAWING 2 ASSEMBLY

More information

FITNESS BIKE. Vision Fitness E3100

FITNESS BIKE. Vision Fitness E3100 FITNESS BIKE Vision Fitness E3100 E3100 Fitness Bike PROPER SEAT POSITIONING To determine the proper seat position, sit on the seat and position the ball of your foot on the centre of the pedal. Your knee

More information

Rediscover dreams. Key Content. DreamStation. Sleep therapy system

Rediscover dreams. Key Content. DreamStation. Sleep therapy system Key Content DreamStation Sleep therapy system Rediscover dreams 2016 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. The Bluetooth word mark and logos

More information

SDS 4.0 Reference Guide

SDS 4.0 Reference Guide SDS 4.0 Reference Guide Content Important information 2 SDS 4.0 Fit and Go Box overview 3 Selecting the receiver length 4 Choosing the correct earpiece for the receiver 5 Attaching / removing the retention

More information

The Progressa bed system

The Progressa bed system The Progressa bed system Bed Controls Tips and Tricks The Progressa bed system Removable Headboard Caregiver Siderail Controls Intellidrive Transport System Controls Caregiver Pendant Removable Footboard

More information

Laerdal-SonoSim Procedure Trainer

Laerdal-SonoSim Procedure Trainer EN Laerdal-SonoSim Procedure Trainer User Guide www.laerdal.com Intended Use The Laerdal-SonoSim Procedure Trainer allows learners the ability to perform ultrasound guidance with real-patient data on multiple

More information

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System GlucCell TM SYSTEM USER S GUIDE Ver 2.1 Intended Use The GlucCell TM Glucose Monitoring System (The GlucCell TM System) is designed to quantitatively measure the concentration of glucose during cell culture.

More information

Nebulizers. Small Volume Nebulizers

Nebulizers. Small Volume Nebulizers Small Volume MICRO MIST Nebulizer The MICRO MIST small volume nebulizer is designed for performance and economy and includes the design features needed by today s respiratory care practitioners. It can

More information

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only Glucose Meter User Guide Veterinary Monitoring System For dog and cat use only Gpet instruction Manual 31/5/09 18:06 Page 2 Gpet instruction Manual 31/5/09 18:06 Page 3 TABLE OF CONTENTS Your g-pet system

More information

Nucleus CP810 Sound Processor User Guide

Nucleus CP810 Sound Processor User Guide Nucleus CP810 Sound Processor User Guide Symbols Note Important information or advice. Can save inconvenience. Caution (no harm) Special care to be taken to ensure safety and effectiveness. Could cause

More information

RELEASED. Clearing your active insulin

RELEASED. Clearing your active insulin To clear all your settings: 1. Make sure the pump is not connected to your body. 2. Go to the Manage Settings screen. Menu > Utilities > Manage Settings 3. Simultaneously press and hold and until the Manage

More information

Model 130 Pulse Oximeter

Model 130 Pulse Oximeter Model 130 Pulse Oximeter User s Manual MEDIAID INC. 17517 Fabrica Way Cerritos California 90703 USA Tel.: 714-367-2848 Fax: 714-367-2852 Web: www.mediaidinc.com Email: info@mediaidinc.com POX010-130 Contents

More information

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber. TRAINING MANUAL AVANT Hearing Instrument Test Chamber HIT+ www.medrx-int.com Contents Getting to know your HIT+... 3 AVANT HIT Software Overview.. 4 AVANT HIT Software Options.... 5 Preparing for Testing...

More information