1 This article was published in an Elsevier journal. The attached copy is furnished to the author for non-commercial research and education use, including for instruction at the author s institution, sharing with colleagues and providing to institution administration. Other uses, including reproduction and distribution, or selling or licensing copies, or posting to personal, institutional or third party websites are prohibited. In most cases authors are permitted to post their version of the article (e.g. in Word or Tex form) to their personal website or institutional repository. Authors requiring further information regarding Elsevier s archiving and manuscript policies are encouraged to visit:

2 Clinical Neurophysiology 119 (2008) Efficient reduction of stimulus artefact in TMS EEG by epithelial short-circuiting by mini-punctures q P. Julkunen a, *,A.Pääkkönen a, T. Hukkanen a,mkönönen a,b, P. Tiihonen a, S. Vanhatalo c, J. Karhu a,d a Department of Clinical Neurophysiology, Kuopio University Hospital, P.O. Box 1777, FI Kuopio, Finland b Department of Radiology, Kuopio University Hospital, Kuopio, Finland c Department of Clinical Neurophysiology, University Hospital of Helsinki, Helsinki, Finland d Nexstim Ltd., Helsinki, Finland Accepted 23 September 2007 Abstract Objective: We aimed at comparing the effects of two different electrode-to-skin contact preparation techniques on the stimulus artefact induced by transcranial magnetic stimulation (TMS) in electroencephalography (EEG) signals. Methods: Six healthy subjects participated in a combined navigated brain stimulation (NBS) and EEG study. Electrode contacts were first prepared in the standard way of rubbing the skin using a wooden stick with a cotton tip. The location of hand motor area and the motor threshold (MT) was determined for each subject. Then, the TMS-induced artefact was measured at 60%, 80%, 100% and 120% of the MT. Subsequently, the epithelium under the electrode contacts was electrically short-circuited by puncturing with custom-made needles and the stimulation sequences were replicated. The artefact was compared between the preparation techniques. Results: The TMS-induced artefact was significantly reduced after puncturing. In addition, the size and duration of the artefact depended on the applied stimulation intensity. The reduction of the artefact was largest in electrodes at and close to the stimulation site. Conclusions: Mini-puncturing technique enables more accurate analysis of TMS-induced short-latency phenomena in EEG during NBS, and it may aid in the examination of the short distance neural connectivity beneath and close to the stimulation site. Significance: This study describes a practical skin preparation method that significantly improves the utility of TMS EEG method in studying short-latency cortical connectivity. Ó 2007 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved. Keywords: Navigated brain stimulation; Transcranial magnetic stimulation; Electroencephalography; Brain; Skin contact 1. Introduction Stimulation of the brain by electrical currents has been used for therapy and diagnostics for decades. Nowadays, high currents conducted directly through skin are no longer necessary. Transcranial magnetic stimulation (TMS) can transfer the electrical current to the desired stimulation focus on the cortex (Barker et al., 1985). TMS has been q Disclosures: Jari Karhu is affiliated with Nexstim Ltd. * Corresponding author. Tel.: ; fax: address: petro.julkunen@kuh.fi (P. Julkunen). used primarily for research purposes in studies of cortical excitability, neuronal connectivity and plasticity, and in the localization of functionally active areas on the cortex (Kahkonen et al., 2004; Kobayashi and Pascual-Leone, 2003; Siebner and Rothwell, 2003; Wright et al., 2006). In the past few years, navigated brain stimulation (NBS) has provided a new, more precise way of transferring the magnetic stimulation to a certain location of the brain by combining magnetic resonance (MR) imaging with advanced image processing methods and navigating systems (Boroojerdi et al., 1999; Ettinger et al., 1998; Gugino et al., 2001; Hannula et al., 2005; Sparing et al., 2007) /$32.00 Ó 2007 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved. doi: /j.clinph

3 476 P. Julkunen et al. / Clinical Neurophysiology 119 (2008) By combining the electroencephalographic (EEG) recordings of the brain activity with TMS, the reactivity and connectivity of intra- and transcortical networks of the brain can be examined (Ilmoniemi et al., 1997; Izumi et al., 1997; Komssi et al., 2002; Schurmann et al., 2001). However, the strong currents induced in the tissue by each TMS-pulse produce large artefacts in the scalp electrodes close to the TMS-coil (Fuggetta et al., 2006; Izumi et al., 1997; Morbidi et al., 2007; Thut et al., 2005). With TMScompatible EEG recording amplifiers, the recording of the EEG can be blocked for the duration of the TMS-pulse using gain control and sample-and-hold circuits (Virtanen et al., 1999). However, the decay of the stimulus-induced charge differences between the electrode-gel and skin occurs in a time-scale that is much longer than the stimulus itself. This time-scale depends on the capacitive and resistive properties of the skin (Swanson and Webster, 1974) (Fig. 1A). Reducing the skin capacitance and resistance by electrical short-circuiting of the epithelial layers should theoretically make the decay of the induced charge differences faster and reduce the TMS-induced artefact in the EEG-electrodes. The skin-borne TMS artefacts are large. Thus, studies have either neglected tens of milliseconds from the beginning of the response (Bonato et al., 2006; Fuggetta et al., 2006), or have applied different types of online and offline artefact removal paradigms (Fuggetta et al., 2006; Ilmoniemi et al., 1997; Morbidi et al., 2007; Thut et al., 2005). This study was set up to characterize the TMS-induced artefact temporally and spatially and to test if a significant reduction of TMS-induced artefact could be achieved by short-circuiting of the epithelial layers by mini-puncturing technique (Burbank and Webster, 1978; Miller et al., 2007; Tallgren, 2005), which has been used to achieve a direct current stable electrode skin interface in Full-band EEG recordings (FbEEG) (Vanhatalo et al., 2005). A reliable comparison between the traditionally used rubbing (abrasion) and the mini-puncture technique was made possible by our NBS system that allows stimulation with highly repeatable coil location and orientation. To the best of our knowledge, the minipuncturing technique has not been used earlier together with TMS EEG. We assumed that short-circuiting (decreasing capacitance and resistance, Fig. 1A) of the skin would result in not just smaller amplitudes of the TMS-induced artefact but also faster recovery from it. This would enable the investigation of cortical short-latency (<25 ms) responses to TMS more accurately and reliably than what has been achieved after conventional skin preparation by rubbing, which typically results in severe EEG artefacts (Bonato et al., 2006; Paus et al., 2001). 2. Methods 2.1. Overview of measurement system Six voluntary healthy subjects (3 male and 3 female) aged years participated in the study. Subjects were scanned with a Siemens Magnetom Avanto (Erlangen, Germany) 1.5T scanner to receive T1-weighted high-resolution 3D MR-images for the NBS. The NBS setup consisted of a navigation system, a stimulator, and a 70 mm figure-of-eight biphasic TMS-coil (Nexstim Ltd., Helsinki, Finland). During NBS, muscle activity was monitored online with an electromyography (EMG) device (ME 6000, Mega Electronics Ltd., Kuopio, Finland), and EEG was recorded with a 60- channel TMS-compatible EEG device (Nexstim Ltd., Helsinki, Finland). All EEG-electrodes were referenced to an electrode placed on the right mastoid. EMG was measured from pre-gelled disposable Ag/AgCl electrodes attached to the opponens pollicis muscle. External triggering pulses controlled by a foot-switch were used to synchronize the TMS, EMG and EEG systems. Triggering pulse was gated to the EEG-amplifier for blocking the EEG input channels for 3 ms in order to prevent saturation of the amplifier (Virtanen et al., 1999) Characterization of the artefact without amplifier blocking The characterization of the artefact was performed using a TDS210 oscilloscope (Tektronix Inc., Beaverton, OR, USA) with high impedance (10 MX) probes by measuring voltage between a reference electrode and an active electrode close to the TMS-coil centre. Two coil types were used for comparison: figure-of-eight biphasic and monophasic (Nexstim Ltd., Helsinki, Finland), both 70 mm in diameter. A pre-gelled disposable Ag/AgCl electrode placed on the right forearm skin on the radialis longus muscle served as an active electrode. A similar reference electrode was placed on the right wrist. The stimuli were delivered straight at the active electrode with the coil plane parallel to the electrode and the distance was fixed to about 0.8 cm. The oscilloscope was triggered with the stimuli. Effect of stimulus intensity on the induced artefact was evaluated with biphasic coil by using 20%, 50% and 80% of the maximum stimulator output Electrode preparation and measurement protocol Subjects were first prepared for combined NBS and EEG recording by rubbing the scalp at the electrode skin contacts using a wooden stick with a cotton tip (Fig. 1) and all electrode locations were digitized. Then, the primary motor cortex area was mapped to locate the optimal cortical representation area of opponens pollicis muscle by finding the highest EMG response. EMG was also used to determine the motor threshold (MT) intensities. A compound muscle action potential with amplitude greater than 50 lv was taken as a reliable response. MT intensity was determined for each subject by finding the lowest NBS stimulation intensity that induced at least 5 responses out of 10 consecutive stimuli. Fifty TMS-pulses were then delivered at the optimal location of the opponens pollicis muscle at three to four

4 P. Julkunen et al. / Clinical Neurophysiology 119 (2008) Fig. 1. (A) Schematic presentation of electrode contacts with rubbing and mini-puncturing of the scalp. Electrical model for the skin was adapted from Swanson and Webster (1974). (B) A custom-made instrument for the mini-puncturing. second intervals. The sequence was repeated with four different intensities: 60%, 80%, 100% and 120% of the determined MT. Both spontaneous and stimulus-locked EEGs were simultaneously measured. The order of the sequences was varied randomly between the subjects. After the four sequences, each electrode contact was punctured through a hole in the electrode (four punctures per electrode). For puncturing the skin, a custom-made mini-puncturing instrument was used (Fig. 1B). This instrument was prepared by inserting a hypodermic needle (Microlance-3 24G mm, BD Medical Systems, Drogheda, Ireland) concentrically through a cut 1.2 mm diameter hypodermic needle so that the sharp tip extended 0.5 mm over the end of the outer needle (blunt gel injection needle, Microlance-3 18G mm, BD Medical Systems, Drogheda, Ireland). The needles were fixed to this position by using hot melt glue. The length of the sharp tip in the instruments and thus the puncturing depth varied between 0.4 and 0.8 mm. The preparation technique was similar to a technique used earlier in the measurements of FbEEG (or direct current coupled EEG; Miller et al., 2007; Tallgren, 2005). After the mini-puncture preparation, the four stimulation sequences were repeated. In the case of one subject, only 10 of the electrode skin contacts were punctured at the stimulation site on the left hemisphere, and the spread of the stimulation artefact was examined EEG recording and analyses The EEG was recorded with a 1450 Hz sampling frequency and 16-bit precision. A triggering signal marking Fig. 2. The TMS-induced potential was measured from a disposable Ag AgCl electrode placed on the arm of one of the authors. The potentials were measured using an oscilloscope. The induced potentials for a biphasic coil are presented at 80% (A) and 50% (B) of the maximum stimulator output. Similarly, induced potentials are presented for monophasic coil at 80% (C) and 40% (D) of the maximum stimulator output. Stimulation moment is indicated by a dashed red line. The peak-to-peak amplitudes of the induced skin potential are also presented. Black downward arrow represents the moment in time when the monophasic pulse has returned to baseline.

5 478 P. Julkunen et al. / Clinical Neurophysiology 119 (2008) the exact stimulation moments was recorded together with the EEG. Vertical electro-oculogram was recorded from electrodes placed above and below the right eye. The recorded EEGs were processed by using a commercial software package Brain Vision Analyzer (Brain Products GmbH, Munich, Germany). The continuous EEG was segmented to 400 ms segments. The segments were averaged with a 100 ms prestimulus baseline. Matlab 7.3 (Mathworks Inc., Natick, MA, USA) was used for analysis of the processed signals. Segments with blinks affecting the induced artefact were removed manually from the analysis. Six electrodes were chosen for the global-field-power (GFP) comparison from those showing the highest TMSinduced artefact under the coil (Fig. 2) (Lehmann and Skrandies, 1980). The GFPs were statistically compared between the two preparation techniques by using non-parametric tests (SPSS 11.5, SPSS Inc., Chicago, IL, USA). To be able to compare the induced artefacts between the subjects, the artefact power was normalized with respect to the artefact power measured with the rubbing preparation. The localized differences were visualized with CURRY v. 4.0 (Compumedics, El Paso, TX, USA). The mini-puncture preparation reduced the signal artefact as compared to rubbing for a certain duration after stimuli. When estimating this duration of improved signal recovery between the preparation techniques, two assumptions were made: (1) pre-stimulus signal and (2) eventrelated brain potentials post-stimuli were not affected by the electrode-to-skin contact preparation. The difference between the preparation techniques was considered to be significant when the absolute difference was higher than two times the standard deviation (SD) of the pre-stimulus (from 100 ms to 0 ms) signal difference. 3. Results In the oscilloscope recordings without amplifier blocking, the biphasic as well as monophasic pulses induced an intensity-dependent response in the skin potential with characteristic response waveforms (Fig. 2). At 80% intensity, the biphasic pulse had an average amplitude of 27.0 V and the monophasic pulse 11.5 V. At 20% and 50% intensity, the biphasic pulses had an average peak-to-peak amplitude of 5.7 V and 18.0 V, respectively. The duration was 300 ls for the biphasic and ls for the monophasic pulse. The amplitudes varied depending on the stimulus intensity. In the EEG recordings with amplifier blocking, the minipuncture preparation of the scalp was more effective than mere rubbing of the scalp in minimizing the TMS-induced EEG artefact (Fig. 3). The decay of the artefact was faster after mini-puncturing compared to rubbing the difference in the size of the artefact between the preparation techniques remained larger than two times the pre-stimulus SD in average to 21 ms after the stimulus. This difference was dependent on the stimulation intensity (Fig. 4). The average pre-stimulus SD was 1.35 lv. Fig. 3. Averaged EEG recording of a single subject is presented showing the location-dependence of the TMS-induced artefact. Six electrodes from area of the artefact were chosen for global-field-power analysis. The signal range was from 100 ms pre-stimulus to 100 ms post-stimulus. TMSinduced artefact is presented for both conditions (rubbed and minipunctured). A close-up from the FC3-electrode signal is presented with amplitudes and recovery times. When examining the GFP of the electrodes most prone to the artefact, a significant (p < 0.05) decrease in the artefact power was observed after the mini-puncture procedure (Fig. 5). The artefact power increased significantly with the TMS intensity (p < 0.01). Altogether, the mini-puncture technique decreased the TMS-induced artefact power up to 93% as compared to the rubbing technique. When evaluating the stimulus artefact by normalizing the artefact power with respect to the artefact after rubbing, the minipuncture technique produced a significantly lower artefact. The significance of the improvement with mini-puncture technique was increased with the TMS intensity (Fig. 5). The spread of the TMS-evoked EEG artefact in a case of mixed electrode-to-skin contact preparation techniques was observed in one male subject. Mini-puncture preparation was performed to 10 electrodes on the left side on the scalp. The boundaries between different preparation tech-

6 P. Julkunen et al. / Clinical Neurophysiology 119 (2008) Fig. 4. The difference in the recovery time between the preparation techniques. This difference was determined finding a post-stimulus timepoint in which the difference between the signals was lower than two times the pre-stimulus SD of the signal difference between the preparations. The results are presented for each stimulation intensity as a group average together with SDs. Fig. 6. Spread of the TMS-induced EEG response at 6 10 ms post-stimuli in a test subject, who had 10 electrode skin contacts on the left side on top of M1 mini-punctured and remaining electrode-to-skin contacts rubbed. The punctured preparation area is surrounded with dashed line. The TMS-pulses with 90% MT were focused ipsilaterally for both conditions (on the left side for the punctured and on the right side for the rubbed). Fig. 5. (A) The normalized power (with respect to power after rubbing) of the TMS-induced artefacts (at 6 ms) is presented separately for each subject as a mean of all intensities. Only 10 of the electrode skin contacts were punctured for subject 6, and thus the artefact powers after rubbing and mini-puncture were computed from different sides. (B) Normalized artefact power (mean of subjects) after mini-puncture with respect to the artefact power after rubbing as a function of stimulation intensity. The effect of the preparation method on the artefact becomes more significant as the stimulation intensity increases. niques are apparent in the scalp potential maps at the time of the artefact maximum (Fig. 6). The right side (prepared with soft rubbing) showed >10 times greater artefact in stimulation area GFP as compared to the left side (prepared with mini-punctures). The TMS-induced EEG artefact decreased in each subject after the mini-puncture preparation. The spatial spreading of the artefact was similar, but its strength was significantly reduced (Fig. 7). Fig. 7. Spread of the TMS-induced artefact after rubbing and minipuncturing are presented for one subject. The TMS-pulses with MT intensity were focused on the left hemisphere. The difference in the spread of induced artefacts of the two techniques is also presented. Potential maps were normalized symmetrically to the maximum potential after rubbing. Below, stimulus-induced electric field densities computed by the stimulation software are presented at depth of 1 mm from the scalp (left) and on the cortex (right). 4. Discussion Studies on cortico-cortical connectivity have been hampered by the drastic stimulation artefacts, which are likely caused by the capacitive properties of the electrode-gel skin circuits (see Fig. 1). In this study we characterized the temporo-spatial properties of this artefact, and we

7 480 P. Julkunen et al. / Clinical Neurophysiology 119 (2008) describe an easy and practical method to significantly reduce the TMS artefact. The TMS-induced artefact during NBS is often mainly restricted to the stimulation area allowing accurate contralateral EEG examination during the stimulation. However, examining the whole spatial spread and short-latency properties of the TMS-evoked EEG response requires minimization of stimulus artefact. As found in this study, the spread of the artefact is clearly affected by the preparation of the electrode contact (Fig. 6). Our results indicate that the electric properties of skin epithelium have a profound effect on the TMS artefact. The conventional skin preparation consists of repeated rubbing of the outer epithelial layers, which is often used in EEG or ECG recordings to reduce the tissue impedance (Burbank and Webster, 1978; Tam and Webster, 1977). However, deeper layers of the skin epithelium, including much of the epithelium and the basal lamina, will remain intact. Their capacitive properties will lead to a charging of the skin after the TMS-pulse, which then gradually discharges and hence yields the long-lasting tail of stimulation artefact. Short-circuiting of this remaining layer by the mini-puncture technique described in the present study eliminates the remaining skin-borne component. It is notable here that mini-puncture alone (i.e. without prior rubbing) will yield about similar effect on skin electric properties (Miller et al., 2007; Tallgren, 2005). Hence our results from mini-puncture do not likely reflect a combined effect of rubbing plus mini-puncture, which in the present study was done just to be able to reliably compare the two preparation techniques. The impact of TMS-induced artefact is centred at the stimulation area below the TMS-coil. Therefore, by neglecting the signals from the electrodes with highest artefact or using signal processing techniques, the harmful effect can be reduced in the analysis. However, a technique that is able to minimize the induced artefact should be used when studying the areas under or close to the TMS-coil. Reducing the stimulation intensity reduced the stimulation artefact (Fig. 6). Recent studies have shown that TMS can evoke detectable EEG responses with very low intensities, which can be used to minimize the intensity-dependent power of the stimulus artefact (Komssi and Kahkonen, 2006; Komssi et al., 2007). The optimal length of the tip (i.e. penetration depth) was not separately studied here, but prior studies have suggested that a depth of <0.5 mm is sufficient to penetrate through the basal lamina (Burbank and Webster, 1978). However, since the skin thickness may vary, and occasional hairs may get under the instrument, previous findings suggest that for reliable results, a tip length of about 0.5 mm is likely more reliable. The short-circuiting procedure can be further ensured by performing repeated strokes (1 5 times; see Miller et al., 2007). It is notable here that an adequate mini-puncture usually does not cause any bleeding, because the skin blood vessels traverse mostly deeper in the subdermal tissue. Any skin lesion, whether due to abrasion or mini-punctures, will expose the skin at risk of infection from exogenous contaminants. While systematic studies are lacking, our own several years experience (incl. Miller et al., 2007), as well as our personal communications with other laboratories, suggests that the risk from mini-puncture is negligible if compared to other skin infections in the hospital environment. As far as the risk of blood-borne contamination from the subject to the measuring devices (Ferree et al., 2001; Putnam et al., 1992) is concerned, it is theoretically possible, but the absence of bleeding and the use of electrode cap without direct skin contacts both efficiently minimize the risk. It is advisable, however, that EEG caps should go through a prudent disinfection or sterilization protocol, and that the mini-puncture tools are made from disposable components. The major practical advantages of the method we describe here are that (i) the mini-puncture instrument can be self-made in every laboratory from the very low cost standard clinical needles, (ii) the needles are disposable, hence there are no sterilization concerns, and (iii) the procedure is very easy to learn, and quick and repeatable to perform. Moreover, our experience from a larger set of FbEEG recordings has shown that the mini-puncture causes usually less discomfort than an adequate rubbing, and the actual skin damage (i.e. invasiveness ) from a tiny epithelial penetration is practically less than after a good rubbing (Miller et al., 2007). The charging of the scalp led to bipolar spread of the artefact potential. This spatial distribution of the artefact resembles the electric field computed by the navigation software below the scalp (Fig. 7). The location of the positive and negative artefact maxima depends on the coil location and orientation (Fig. 3). The investigation of the TMS-induced artefact as a skin potential measured from forearm with an oscilloscope indicated that the EEG-amplifier s gain control and sampleand-hold circuits are good at guarding the TMS-related phenomena from the artefact. When comparing the amplitude of the artefact in forearm experiments with biphasic coil with the amplitude of the TMS-induced artefact in EEG from one subject s recording with the same intensity, the reduction of the highest possible artefact was 99.99% independent from the electrode contact preparation. The remaining artefact may be reduced by electrode contact preparation techniques, such as used in this study, and with offline artefact removal (Morbidi et al., 2007). There are differences between the TMS-coils and their ability to induce artefacts. As we used a biphasic figureof-eight coil in our study, we cannot make direct conclusions of the behaviour of mini-puncture technique with monophasic coils and coils with different construction or design. When comparing monophasic and biphasic coils, the measured potential between the electrodes was significantly different (Fig. 2). As the monophasic coil induces mainly a single potential rise, the galvanic effect is supposed to be emphasized since the opposite discharging

8 P. Julkunen et al. / Clinical Neurophysiology 119 (2008) phase (second, as in biphasic) is small or missing. Thus, we believe that mini-puncture technique could prove to be even more significant when using a monophasic coil together with EEG. In addition, EEG may be more prone to the intensity changes of monophasic pulse, because the duration of elevated skin potential seems to be dependent on the stimulation intensity (Fig. 2). Nevertheless, the induced potentials over the skin are normally lower when using monophasic coils due to a lower power of the induced magnetic field as compared to the biphasic coils. 5. Conclusions We conclude that TMS induces severe artefacts in the recorded EEG when applying high TMS intensities above MT. These artefacts are likely to originate from the skin. However, the artefacts are reduced when stimulation intensities below MT are used. In addition, TMS-induced artefact contaminated a significantly smaller area in the EEG when using mini-puncture preparation. Especially, the mini-puncture method is useful in the analysis of TMSevoked EEG responses with latencies shorter than 25 ms. Acknowledgement This study was supported by the Finnish Funding Agency for Technology and Innovation (TEKES) Helsinki, Finland. References Barker AT, Jalinous R, Freeston IL. Non-invasive magnetic stimulation of human motor cortex. Lancet 1985;1: Bonato C, Miniussi C, Rossini PM. Transcranial magnetic stimulation and cortical evoked potentials: a TMS/EEG co-registration study. Clin Neurophysiol 2006;117: Boroojerdi B, Foltys H, Krings T, Spetzger U, Thron A, Topper R. Localization of the motor hand area using transcranial magnetic stimulation and functional magnetic resonance imaging. Clin Neurophysiol 1999;110: Burbank DP, Webster JG. Reducing skin potential motion artefact by skin abrasion. Med Biol Eng Comput 1978;16:31 8. Ettinger GJ, Leventon ME, Grimson WE, Kikinis R, Gugino L, Cote W, et al. Experimentation with a transcranial magnetic stimulation system for functional brain mapping. Med Image Anal 1998;2: Ferree TC, Luu P, Russell GS, Tucker DM. Scalp electrode impedance, infection risk, and EEG data quality. Clin Neurophysiol 2001;112: Fuggetta G, Pavone EF, Walsh V, Kiss M, Eimer M. Cortico-cortical interactions in spatial attention: A combined ERP/TMS study. J Neurophysiol 2006;95: Gugino LD, Romero JR, Aglio L, Titone D, Ramirez M, Pascual-Leone A, et al. Transcranial magnetic stimulation coregistered with MRI: a comparison of a guided versus blind stimulation technique and its effect on evoked compound muscle action potentials. Clin Neurophysiol 2001;112: Hannula H, Ylioja S, Pertovaara A, Korvenoja A, Ruohonen J, Ilmoniemi RJ, et al. Somatotopic blocking of sensation with navigated transcranial magnetic stimulation of the primary somatosensory cortex. Hum Brain Mapp 2005;26: Ilmoniemi RJ, Virtanen J, Ruohonen J, Karhu J, Aronen HJ, Näätänen R, et al. Neuronal responses to magnetic stimulation reveal cortical reactivity and connectivity. Neuroreport 1997;10: Izumi S, Takase M, Arita M, Masakado Y, Kimura A, Chino N. Transcranial magnetic stimulation-induced changes in EEG and responses recorded from the scalp of healthy humans. Electroencephalogr Clin Neurophysiol 1997;103: Kahkonen S, Wilenius J, Komssi S, Ilmoniemi RJ. Distinct differences in cortical reactivity of motor and prefrontal cortices to magnetic stimulation. Clin Neurophysiol 2004;115: Kobayashi M, Pascual-Leone A. Transcranial magnetic stimulation in neurology. Lancet Neurol 2003;2: Komssi S, Aronen HJ, Huttunen J, Kesaniemi M, Soinne L, Nikouline VV, et al. Ipsi- and contralateral EEG reactions to transcranial magnetic stimulation. Clin Neurophysiol 2002;113: Komssi S, Kahkonen S. The novelty value of the combined use of electroencephalography and transcranial magnetic stimulation for neuroscience research. Brain Res Rev 2006;52: Komssi S, Savolainen P, Heiskala J, Kahkonen S. Excitation threshold of the motor cortex estimated with transcranial magnetic stimulation electroencephalography. Neuroreport 2007;18:13 6. Lehmann D, Skrandies W. Reference-free identification of components of checkerboard-evoked multichannel potential fields. Electroencephalogr Clin Neurophysiol 1980;48: Miller JW, Kim W, Holmes MD, Vanhatalo S. Ictal localization by source analysis of infraslow activity in DC-coupled scalp EEG recordings. Neuroimage 2007;35: Morbidi F, Garulli A, Prattichizzo D, Rizzo C, Manganotti P, Rossi S. Off-line removal of TMS-induced artifacts on human electroencephalography by Kalman filter. J Neurosci Methods 2007;162: Paus T, Sipila PK, Strafella AP. Synchronization of neuronal activity in the human primary motor cortex by transcranial magnetic stimulation: an EEG study. J Neurophysiol 2001;86: Putnam LE, Johnson Jr R, Roth WT. Guidelines for reducing the risk of disease transmission in the psychophysiology laboratory. SPR Ad Hoc Committee on the Prevention of Disease Transmission. Psychophysiology 1992;29: Schurmann M, Nikouline VV, Soljanlahti S, Ollikainen M, Basar E, Ilmoniemi RJ. EEG responses to combined somatosensory and transcranial magnetic stimulation. Clin Neurophysiol 2001;112: Siebner HR, Rothwell J. Transcranial magnetic stimulation: new insights into representational cortical plasticity. Exp Brain Res 2003;148:1 16. Sparing R, Buelte D, Meister IG, Paus T, Fink GR. Transcranial magnetic stimulation and the challenge of coil placement: A comparison of conventional and stereotaxic neuronavigational strategies. Hum Brain Mapp Swanson DK, Webster JG. A model for skin-electrode impedance. In: Miller HA, Harrison DC, editors. Biomedical electrode technology Theory and practice. New York: Academic Press; p Tallgren P. DC-stable electrode skin interface for human EEG recordings. Series E: Electronic Publications E 5 ( Elektroniikka/reports), Helsinki, Tam HW, Webster JG. Minimizing electrode motion artifact by skin abrasion. IEEE Trans Biomed Eng 1977;24: Thut G, Ives JR, Kampmann F, Pastor MA, Pascual-Leone A. A new device and protocol for combining TMS and online recordings of EEG and evoked potentials. J Neurosci Methods 2005;141: Vanhatalo S, Voipio J, Kaila K. Full-band EEG (FbEEG): an emerging standard in electroencephalography. Clin Neurophysiol 2005;116:1 8. Virtanen J, Ruohonen J, Naatanen R, Ilmoniemi RJ. Instrumentation for the measurement of electric brain responses to transcranial magnetic stimulation. Med Biol Eng Comput 1999;37: Wright MA, Orth M, Patsalos PN, Smith SJ, Richardson MP. Cortical excitability predicts seizures in acutely drug-reduced temporal lobe epilepsy patients. Neurology 2006;67:

Introduction to TMS Transcranial Magnetic Stimulation

Introduction to TMS Transcranial Magnetic Stimulation Introduction to TMS Transcranial Magnetic Stimulation Lisa Koski, PhD, Clin Psy TMS Neurorehabilitation Lab Royal Victoria Hospital 2009-12-14 BIC Seminar, MNI Overview History, basic principles, instrumentation

More information

Clinical Neurophysiology

Clinical Neurophysiology Clinical Neurophysiology 12 (29) 1392 1399 Contents lists available at ScienceDirect Clinical Neurophysiology journal homepage: www.elsevier.com/locate/clinph TMS-EEG co-registration: On TMS-induced artifact

More information

The Contribution of TMS-EEG Coregistration in the Exploration of the Human Connectome

The Contribution of TMS-EEG Coregistration in the Exploration of the Human Connectome IRCCS San Giovanni di Dio Fatebenefratelli The Contribution of TMS-EEG Coregistration in the Exploration of the Human Connectome Marta Bortoletto Carlo Miniussi Cognitive Neuroscience Section, The Saint

More information

Synchronizing the transcranial magnetic pulse with electroencephalographic recordings. effectively reduces inter-trial variability of the pulse

Synchronizing the transcranial magnetic pulse with electroencephalographic recordings. effectively reduces inter-trial variability of the pulse RESEARCH ARTICLE Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact Leo Tomasevic 1 *, Mitsuaki Takemi

More information

What is NBS? Nextstim NBS System

What is NBS? Nextstim NBS System Nextstim NBS System What is NBS? NBS means navigated brain stimulation, and is used to precisely map the areas controlling muscle movements/activity in the brain. This procedure provides advanced patient

More information

BME 701 Examples of Biomedical Instrumentation. Hubert de Bruin Ph D, P Eng

BME 701 Examples of Biomedical Instrumentation. Hubert de Bruin Ph D, P Eng BME 701 Examples of Biomedical Instrumentation Hubert de Bruin Ph D, P Eng 1 Instrumentation in Cardiology The major cellular components of the heart are: working muscle of the atria & ventricles specialized

More information

NIH Public Access Author Manuscript Conf Proc IEEE Eng Med Biol Soc. Author manuscript; available in PMC 2010 January 1.

NIH Public Access Author Manuscript Conf Proc IEEE Eng Med Biol Soc. Author manuscript; available in PMC 2010 January 1. NIH Public Access Author Manuscript Published in final edited form as: Conf Proc IEEE Eng Med Biol Soc. 2009 ; 1: 4719 4722. doi:10.1109/iembs.2009.5334195. Estimation of Brain State Changes Associated

More information

AdvAnced TMS. Research with PowerMAG Products and Application Booklet

AdvAnced TMS. Research with PowerMAG Products and Application Booklet AdvAnced TMS Research with PowerMAG Products and Application Booklet Table of ConTenTs Introduction p. 04 Legend p. 06 Applications» navigated TMS p. 08» clinical Research p. 10» Multi-Modal TMS p. 12»

More information

Chapter 5 Accessing Cortical Connectivity Using TMS: EEG Co-registration

Chapter 5 Accessing Cortical Connectivity Using TMS: EEG Co-registration Chapter 5 Accessing Cortical Connectivity Using TMS: EEG Co-registration TMS and Connectivity Carlo Miniussi, Marta Bortoletto, Gregor Thut and Domenica Veniero Abstract The combination of brain stimulation

More information

Neurophysiological Basis of TMS Workshop

Neurophysiological Basis of TMS Workshop Neurophysiological Basis of TMS Workshop Programme 31st March - 3rd April 2017 Sobell Department Institute of Neurology University College London 33 Queen Square London WC1N 3BG Brought to you by 31 March

More information

Neuro-MS/D DIAGNOSTICS REHABILITATION TREATMENT STIMULATION. Transcranial Magnetic Stimulator. of motor disorders after the stroke

Neuro-MS/D DIAGNOSTICS REHABILITATION TREATMENT STIMULATION. Transcranial Magnetic Stimulator. of motor disorders after the stroke Neuro-MS/D Transcranial Magnetic Stimulator DIAGNOSTICS of corticospinal pathway pathology REHABILITATION of motor disorders after the stroke TREATMENT of depression and Parkinson s disease STIMULATION

More information

Behavioural Brain Research

Behavioural Brain Research Behavioural Brain Research 191 (2008) 141 147 Contents lists available at ScienceDirect Behavioural Brain Research journal homepage: www.elsevier.com/locate/bbr Review Combining TMS and EEG to study cognitive

More information

Combining TMS and EEG Offers New Prospects in Cognitive Neuroscience

Combining TMS and EEG Offers New Prospects in Cognitive Neuroscience Brain Topogr (2010) 22:249 256 DOI 10.1007/s10548-009-0083-8 ORIGINAL PAPER Combining TMS and EEG Offers New Prospects in Cognitive Neuroscience Carlo Miniussi Æ Gregor Thut Received: 25 November 2008

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,900 116,000 120M Open access books available International authors and editors Downloads Our

More information

Publication V. "Oppikirjan julkaiseminen on päivän kunnia ja loppuelämän häpeä. Väitöskirja on päivän häpeä mutta loppuelämän kunnia.

Publication V. Oppikirjan julkaiseminen on päivän kunnia ja loppuelämän häpeä. Väitöskirja on päivän häpeä mutta loppuelämän kunnia. Publication V Vanhatalo S, Tallgren P, Andersson S, Sainio K, Voipio J, Kaila K. DC-EEG discloses prominent, very slow activity patterns during sleep in preterm infants. Clinical Neurophysiology, 2002,

More information

Supplementary Information on TMS/hd-EEG recordings: acquisition and preprocessing

Supplementary Information on TMS/hd-EEG recordings: acquisition and preprocessing Supplementary Information on TMS/hd-EEG recordings: acquisition and preprocessing Stability of the coil position was assured by using a software aiming device allowing the stimulation only when the deviation

More information

EEG Responses to TMS Are Sensitive to Changes in the Perturbation Parameters and Repeatable over Time

EEG Responses to TMS Are Sensitive to Changes in the Perturbation Parameters and Repeatable over Time EEG Responses to TMS Are Sensitive to Changes in the Perturbation Parameters and Repeatable over Time Silvia Casarotto, Leonor J. Romero Lauro, Valentina Bellina, Adenauer G. Casali, Mario Rosanova, Andrea

More information

Neurosoft TMS. Transcranial Magnetic Stimulator DIAGNOSTICS REHABILITATION TREATMENT STIMULATION. of motor disorders after the stroke

Neurosoft TMS. Transcranial Magnetic Stimulator DIAGNOSTICS REHABILITATION TREATMENT STIMULATION. of motor disorders after the stroke Neurosoft TMS Transcranial Magnetic Stimulator DIAGNOSTICS REHABILITATION TREATMENT of corticospinal pathways pathology of motor disorders after the stroke of depression and Parkinson s disease STIMULATION

More information

Electroencephalography

Electroencephalography The electroencephalogram (EEG) is a measure of brain waves. It is a readily available test that provides evidence of how the brain functions over time. The EEG is used in the evaluation of brain disorders.

More information

Biomedical Research 2013; 24 (3): ISSN X

Biomedical Research 2013; 24 (3): ISSN X Biomedical Research 2013; 24 (3): 359-364 ISSN 0970-938X http://www.biomedres.info Investigating relative strengths and positions of electrical activity in the left and right hemispheres of the human brain

More information

CHAPTER 6 INTERFERENCE CANCELLATION IN EEG SIGNAL

CHAPTER 6 INTERFERENCE CANCELLATION IN EEG SIGNAL 116 CHAPTER 6 INTERFERENCE CANCELLATION IN EEG SIGNAL 6.1 INTRODUCTION Electrical impulses generated by nerve firings in the brain pass through the head and represent the electroencephalogram (EEG). Electrical

More information

An Overview of BMIs. Luca Rossini. Workshop on Brain Machine Interfaces for Space Applications

An Overview of BMIs. Luca Rossini. Workshop on Brain Machine Interfaces for Space Applications An Overview of BMIs Luca Rossini Workshop on Brain Machine Interfaces for Space Applications European Space Research and Technology Centre, European Space Agency Noordvijk, 30 th November 2009 Definition

More information

Novel single trial movement classification based on temporal dynamics of EEG

Novel single trial movement classification based on temporal dynamics of EEG Novel single trial movement classification based on temporal dynamics of EEG Conference or Workshop Item Accepted Version Wairagkar, M., Daly, I., Hayashi, Y. and Nasuto, S. (2014) Novel single trial movement

More information

Outline of Talk. Introduction to EEG and Event Related Potentials. Key points. My path to EEG

Outline of Talk. Introduction to EEG and Event Related Potentials. Key points. My path to EEG Outline of Talk Introduction to EEG and Event Related Potentials Shafali Spurling Jeste Assistant Professor in Psychiatry and Neurology UCLA Center for Autism Research and Treatment Basic definitions and

More information

NEURO-MS TMS. Diagnostic Monophasic Magnetic Stimulator

NEURO-MS TMS. Diagnostic Monophasic Magnetic Stimulator NEURO-MS Diagnostic Monophasic Magnetic Stimulator Diagnostics of neurological disorders Powerful monophasic stimulus Ergonomic and lightweight coils of different shapes and sizes Configurations for single

More information

Descriptions of NDT Projects Fall 2004 October 31, 2004

Descriptions of NDT Projects Fall 2004 October 31, 2004 Descriptions of NDT Projects Fall 2004 October 31, 2004 Introduction There are two separate NDT labs in Magister: ULTRA for ultrasound and EDDY for eddy current. Both labs are equipped with mechanical

More information

Introduction to Electrophysiology

Introduction to Electrophysiology Introduction to Electrophysiology Dr. Kwangyeol Baek Martinos Center for Biomedical Imaging Massachusetts General Hospital Harvard Medical School 2018-05-31s Contents Principles in Electrophysiology Techniques

More information

A Brain Computer Interface System For Auto Piloting Wheelchair

A Brain Computer Interface System For Auto Piloting Wheelchair A Brain Computer Interface System For Auto Piloting Wheelchair Reshmi G, N. Kumaravel & M. Sasikala Centre for Medical Electronics, Dept. of Electronics and Communication Engineering, College of Engineering,

More information

Water immersion modulates sensory and motor cortical excitability

Water immersion modulates sensory and motor cortical excitability Water immersion modulates sensory and motor cortical excitability Daisuke Sato, PhD Department of Health and Sports Niigata University of Health and Welfare Topics Neurophysiological changes during water

More information

Effects of single-pulse transcranial magnetic stimulation (TMS) on functional brain activity: a combined event-related TMS and evoked potential study

Effects of single-pulse transcranial magnetic stimulation (TMS) on functional brain activity: a combined event-related TMS and evoked potential study Clinical Neurophysiology 114 (2003) 2071 2080 www.elsevier.com/locate/clinph Effects of single-pulse transcranial magnetic stimulation (TMS) on functional brain activity: a combined event-related TMS and

More information

Neural Networks: Tracing Cellular Pathways. Lauren Berryman Sunfest 2000

Neural Networks: Tracing Cellular Pathways. Lauren Berryman Sunfest 2000 Neural Networks: Tracing Cellular Pathways Lauren Berryman Sunfest 000 Neural Networks: Tracing Cellular Pathways Research Objective Background Methodology and Experimental Approach Results and Conclusions

More information

Effect of Transcranial Magnetic Stimulation(TMS) on Visual Search Task

Effect of Transcranial Magnetic Stimulation(TMS) on Visual Search Task INTERNATIONAL JOURNAL OF APPLIED BIOMEDICAL ENGINEERING VOL.2, NO.2 2009 1 Effect of Transcranial Magnetic Stimulation(TMS) on Visual Search Task K. Iramina, Guest member ABSTRACT Transcranial magnetic

More information

Quantitative Electrophysiology

Quantitative Electrophysiology ECE 795: Quantitative Electrophysiology Notes for Lecture #10 Wednesday, November 22, 2006 14. FUNDAMENTALS OF FUNCTIONAL ELECTRICAL STIMULATION (FES) We will look at: Design issues for FES Subthreshold

More information

EE 4BD4 Lecture 11. The Brain and EEG

EE 4BD4 Lecture 11. The Brain and EEG EE 4BD4 Lecture 11 The Brain and EEG 1 Brain Wave Recordings Recorded extra-cellularly from scalp (EEG) Recorded from extra-cellularly from surface of cortex (ECOG) Recorded extra-cellularly from deep

More information

MagPro by MagVenture. Versatility in Magnetic Stimulation

MagPro by MagVenture. Versatility in Magnetic Stimulation MagPro by MagVenture Versatility in Magnetic Stimulation MagPro A proven Record of Innovation With 7 different magnetic stimulators and 27 different coils, the MagPro line from MagVenture provides the

More information

Transcranial Magnetic Stimulation

Transcranial Magnetic Stimulation Transcranial Magnetic Stimulation Session 4 Virtual Lesion Approach I Alexandra Reichenbach MPI for Biological Cybernetics Tübingen, Germany Today s Schedule Virtual Lesion Approach : Study Design Rationale

More information

Early posterior ERP components do not reflect the control of attentional shifts toward expected peripheral events

Early posterior ERP components do not reflect the control of attentional shifts toward expected peripheral events Psychophysiology, 40 (2003), 827 831. Blackwell Publishing Inc. Printed in the USA. Copyright r 2003 Society for Psychophysiological Research BRIEF REPT Early posterior ERP components do not reflect the

More information

Neuro-MS/D Transcranial Magnetic Stimulator

Neuro-MS/D Transcranial Magnetic Stimulator Neuro-MS/D Transcranial Magnetic Stimulator 20 Hz stimulation with 100% intensity Peak magnetic field - up to 4 T High-performance cooling: up to 10 000 pulses during one session Neuro-MS.NET software

More information

TMS Disruption of Time Encoding in Human Primary Visual Cortex Molly Bryan Beauchamp Lab

TMS Disruption of Time Encoding in Human Primary Visual Cortex Molly Bryan Beauchamp Lab TMS Disruption of Time Encoding in Human Primary Visual Cortex Molly Bryan Beauchamp Lab This report details my summer research project for the REU Theoretical and Computational Neuroscience program as

More information

PHYSIOLOGICAL RESEARCH

PHYSIOLOGICAL RESEARCH DOMAIN STUDIES PHYSIOLOGICAL RESEARCH In order to understand the current landscape of psychophysiological evaluation methods, we conducted a survey of academic literature. We explored several different

More information

This presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute.

This presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute. Modified Combinatorial Nomenclature Montage, Review, and Analysis of High Density EEG Terrence D. Lagerlund, M.D., Ph.D. CP1208045-16 Disclosure Relevant financial relationships None Off-label/investigational

More information

The Sonification of Human EEG and other Biomedical Data. Part 3

The Sonification of Human EEG and other Biomedical Data. Part 3 The Sonification of Human EEG and other Biomedical Data Part 3 The Human EEG A data source for the sonification of cerebral dynamics The Human EEG - Outline Electric brain signals Continuous recording

More information

Combining tdcs and fmri. OHMB Teaching Course, Hamburg June 8, Andrea Antal

Combining tdcs and fmri. OHMB Teaching Course, Hamburg June 8, Andrea Antal Andrea Antal Department of Clinical Neurophysiology Georg-August University Goettingen Combining tdcs and fmri OHMB Teaching Course, Hamburg June 8, 2014 Classical Biomarkers for measuring human neuroplasticity

More information

The neurolinguistic toolbox Jonathan R. Brennan. Introduction to Neurolinguistics, LSA2017 1

The neurolinguistic toolbox Jonathan R. Brennan. Introduction to Neurolinguistics, LSA2017 1 The neurolinguistic toolbox Jonathan R. Brennan Introduction to Neurolinguistics, LSA2017 1 Psycholinguistics / Neurolinguistics Happy Hour!!! Tuesdays 7/11, 7/18, 7/25 5:30-6:30 PM @ the Boone Center

More information

Electrical recording with micro- and macroelectrodes from the cerebellum of man

Electrical recording with micro- and macroelectrodes from the cerebellum of man Electrical recording with micro- and macroelectrodes from the cerebellum of man D. GRAHAM SLAUGHTER, M.D., BLAINE S. NASHOLD, Jn., M.D., AND GEORGE G. SOMJEN, M.D. The Division of Neurosurgery, and the

More information

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Jason Silver August 26, 2009 Presentation Outline Introduction Thesis Objectives Mathematical Model and Principles Methods

More information

MagPro by MagVenture. Versatility in Magnetic Stimulation

MagPro by MagVenture. Versatility in Magnetic Stimulation MagPro by MagVenture Versatility in Magnetic Stimulation MagPro A proven record of innovation With 7 different magnetic stimulators and 33 different coils, the MagPro line from MagVenture provides the

More information

Statement on Repetitive Transcranial Magnetic Stimulation for Depression. Position statement CERT03/17

Statement on Repetitive Transcranial Magnetic Stimulation for Depression. Position statement CERT03/17 Statement on Repetitive Transcranial Magnetic Stimulation for Depression Position statement CERT03/17 Approved by the Royal College of Psychiatrists, Committee on ECT and Related Treatments: February 2017

More information

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards Neuro-MEP-Micro 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard EMG according to international standards Instant analysis of high-quality responses Over 50 EMG and EP

More information

Effects of Sub-Motor-Threshold Transcranial Magnetic Stimulation on. Event-Related Potentials and Motor-Evoked Potentials

Effects of Sub-Motor-Threshold Transcranial Magnetic Stimulation on. Event-Related Potentials and Motor-Evoked Potentials 東海大学基盤工学部紀要 5(2017 年 )1 頁 ~6 頁 Bull. School of Industrial and Welfare Engineering Tokai Univ., 5(2017), pp.1-6 Effects of Sub-Motor-Threshold Transcranial Magnetic Stimulation on Event-Related Potentials

More information

Neurobiology Biomed 509 Sensory transduction References: Luo , ( ), , M4.1, M6.2

Neurobiology Biomed 509 Sensory transduction References: Luo , ( ), , M4.1, M6.2 Neurobiology Biomed 509 Sensory transduction References: Luo 4.1 4.8, (4.9 4.23), 6.22 6.24, M4.1, M6.2 I. Transduction The role of sensory systems is to convert external energy into electrical signals

More information

DATA MANAGEMENT & TYPES OF ANALYSES OFTEN USED. Dennis L. Molfese University of Nebraska - Lincoln

DATA MANAGEMENT & TYPES OF ANALYSES OFTEN USED. Dennis L. Molfese University of Nebraska - Lincoln DATA MANAGEMENT & TYPES OF ANALYSES OFTEN USED Dennis L. Molfese University of Nebraska - Lincoln 1 DATA MANAGEMENT Backups Storage Identification Analyses 2 Data Analysis Pre-processing Statistical Analysis

More information

TMS: Full Board or Expedited?

TMS: Full Board or Expedited? TMS: Full Board or Expedited? Transcranial Magnetic Stimulation: - Neurostimulation or neuromodulation technique based on the principle of electro-magnetic induction of an electric field in the brain.

More information

ELECTROENCEPHALOGRAPHIC RESPONSES TO TRANSCRANIAL MAGNETIC STIMULATION

ELECTROENCEPHALOGRAPHIC RESPONSES TO TRANSCRANIAL MAGNETIC STIMULATION UNIVERSITY OF HELSINKI REPORT SERIES IN PHYSICS HU-P-D119 ELECTROENCEPHALOGRAPHIC RESPONSES TO TRANSCRANIAL MAGNETIC STIMULATION Soile Komssi Department of Physical Sciences Faculty of Science University

More information

Quick Guide - eabr with Eclipse

Quick Guide - eabr with Eclipse What is eabr? Quick Guide - eabr with Eclipse An electrical Auditory Brainstem Response (eabr) is a measurement of the ABR using an electrical stimulus. Instead of a traditional acoustic stimulus the cochlear

More information

Neuroimaging biomarkers and predictors of motor recovery: implications for PTs

Neuroimaging biomarkers and predictors of motor recovery: implications for PTs Neuroimaging biomarkers and predictors of motor recovery: implications for PTs 2018 Combined Sections Meeting of the American Physical Therapy Association New Orleans, LA February 21-24, 2018 Presenters:

More information

Evaluation of algorithms for correction of transcranial magnetic stimulation induced artifacts in electroencephalograms

Evaluation of algorithms for correction of transcranial magnetic stimulation induced artifacts in electroencephalograms Evaluation of algorithms for correction of transcranial magnetic stimulation induced artifacts in electroencephalograms Panteleimon Vafeidis a,*, Vasilios K. Kimiskidis b, Dimitris Kugiumtzis c a Bernstein

More information

PD233: Design of Biomedical Devices and Systems

PD233: Design of Biomedical Devices and Systems PD233: Design of Biomedical Devices and Systems (Lecture-7 Biopotentials- 2) Dr. Manish Arora CPDM, IISc Course Website: http://cpdm.iisc.ac.in/utsaah/courses/ Electromyogram (EMG) Skeletal muscles are

More information

Electrophysiologic approaches to delirium. Overview

Electrophysiologic approaches to delirium. Overview Electrophysiologic approaches to delirium Alvaro Pascual Leone, MD, PhD Mouhsin Shafi, MD, PhD Overview Overview of the problem and techniques Electrophysiological studies in delirium Electrophysiological

More information

EEG, ECG, EMG. Mitesh Shrestha

EEG, ECG, EMG. Mitesh Shrestha EEG, ECG, EMG Mitesh Shrestha What is Signal? A signal is defined as a fluctuating quantity or impulse whose variations represent information. The amplitude or frequency of voltage, current, electric field

More information

Transcranial magnetic stimulation and cortical evoked potentials: A TMS/EEG co-registration study

Transcranial magnetic stimulation and cortical evoked potentials: A TMS/EEG co-registration study Clinical Neurophysiology 117 (2006) 1699 1707 www.elsevier.com/locate/clinph Transcranial magnetic stimulation and cortical evoked potentials: A TMS/EEG co-registration study C. Bonato a, C. Miniussi a,b,

More information

EEG Instrumentation, Montage, Polarity, and Localization

EEG Instrumentation, Montage, Polarity, and Localization EEG Instrumentation, Montage, Polarity, and Localization 2 Krikor Tufenkjian The Source of EEG The source of the EEG potentials recorded from the scalp is the excitatory and inhibitory postsynaptic potentials

More information

Insights on the neural basis of motor plasticity induced by theta burst stimulation from TMS EEG

Insights on the neural basis of motor plasticity induced by theta burst stimulation from TMS EEG European Journal of Neuroscience European Journal of Neuroscience, Vol. 37, pp. 598 606, 2013 doi:10.1111/ejn.12069 NEUROSYSTEMS Insights on the neural basis of motor plasticity induced by theta burst

More information

Spike voltage topography in temporal lobe epilepsy

Spike voltage topography in temporal lobe epilepsy Thomas Jefferson University Jefferson Digital Commons Department of Neurology Faculty Papers Department of Neurology 5-17-2016 Spike voltage topography in temporal lobe epilepsy Ali Akbar Asadi-Pooya Thomas

More information

Diagnosing Complicated Epilepsy: Mapping of the Epileptic Circuitry. Michael R. Sperling, M.D. Thomas Jefferson University Philadelphia, PA

Diagnosing Complicated Epilepsy: Mapping of the Epileptic Circuitry. Michael R. Sperling, M.D. Thomas Jefferson University Philadelphia, PA Diagnosing Complicated Epilepsy: Mapping of the Epileptic Circuitry Michael R. Sperling, M.D. Thomas Jefferson University Philadelphia, PA Overview Definition of epileptic circuitry Methods of mapping

More information

Implantable Microelectronic Devices

Implantable Microelectronic Devices ECE 8803/4803 Implantable Microelectronic Devices Fall - 2015 Maysam Ghovanloo (mgh@gatech.edu) School of Electrical and Computer Engineering Georgia Institute of Technology 2015 Maysam Ghovanloo 1 Outline

More information

EEG in the ICU: Part I

EEG in the ICU: Part I EEG in the ICU: Part I Teneille E. Gofton July 2012 Objectives To outline the importance of EEG monitoring in the ICU To briefly review the neurophysiological basis of EEG To introduce formal EEG and subhairline

More information

EEG-Correlated Functional MRI: Recent Methodologic Progress and Current Issues

EEG-Correlated Functional MRI: Recent Methodologic Progress and Current Issues Epilepsia, 43(Suppl. 1):64 68, 2002 Blackwell Publishing International League Against Epilepsy EEG-Correlated Functional MRI: Recent Methodologic Progress and Current Issues * Louis Lemieux, * Afraim Salek-Haddadi,

More information

Event-Related Potentials Recorded during Human-Computer Interaction

Event-Related Potentials Recorded during Human-Computer Interaction Proceedings of the First International Conference on Complex Medical Engineering (CME2005) May 15-18, 2005, Takamatsu, Japan (Organized Session No. 20). Paper No. 150, pp. 715-719. Event-Related Potentials

More information

Physiological and Physical Basis of Functional Brain Imaging 6. EEG/MEG. Kâmil Uludağ, 20. November 2007

Physiological and Physical Basis of Functional Brain Imaging 6. EEG/MEG. Kâmil Uludağ, 20. November 2007 Physiological and Physical Basis of Functional Brain Imaging 6. EEG/MEG Kâmil Uludağ, 20. November 2007 Course schedule 1. Overview 2. fmri (Spin dynamics, Image formation) 3. fmri (physiology) 4. fmri

More information

Amy Kruse, Ph.D. Strategic Analysis, Inc. LCDR Dylan Schmorrow USN Defense Advanced Research Projects Agency

Amy Kruse, Ph.D. Strategic Analysis, Inc. LCDR Dylan Schmorrow USN Defense Advanced Research Projects Agency What can modern neuroscience technologies offer the forward-looking applied military psychologist? Exploring the current and future use of EEG and NIR in personnel selection and training. Amy Kruse, Ph.D.

More information

MOTOR EVOKED POTENTIALS AND TRANSCUTANEOUS MAGNETO-ELECTRICAL NERVE STIMULATION

MOTOR EVOKED POTENTIALS AND TRANSCUTANEOUS MAGNETO-ELECTRICAL NERVE STIMULATION MOTOR EVOKED POTENTIAS AND TRANSCUTANEOUS MAGNETO-EECTRICA NERVE STIMUATION Hongguang iu, in Zhou 1 and Dazong Jiang Xian Jiaotong University, Xian, People s Republic of China 1 Shanxi Normal University,

More information

1- Cochlear Impedance Telemetry

1- Cochlear Impedance Telemetry INTRA-OPERATIVE COCHLEAR IMPLANT MEASURMENTS SAMIR ASAL M.D 1- Cochlear Impedance Telemetry 1 Cochlear implants used presently permit bi--directional communication between the inner and outer parts of

More information

Using Transcranial magnetic stimulation to improve our understanding of Transverse Myelitis

Using Transcranial magnetic stimulation to improve our understanding of Transverse Myelitis Using Transcranial magnetic stimulation to improve our understanding of Transverse Myelitis Kathy Zackowski, PhD, OTR Kennedy Krieger Institute Johns Hopkins University School of Medicine TMS (transcranial

More information

Oscillations: From Neuron to MEG

Oscillations: From Neuron to MEG Oscillations: From Neuron to MEG Educational Symposium, MEG UK 2014, Nottingham, Jan 8th 2014 Krish Singh CUBRIC, School of Psychology Cardiff University What are we trying to achieve? Bridge the gap from

More information

Spatial localisation of EEG dipoles in MRI using the International System anatomical references

Spatial localisation of EEG dipoles in MRI using the International System anatomical references Proc. of First Int'l Workshop on Image and Signal Processing and Analysis Spatial localisation of EEG dipoles in MRI using the 10-20 International System anatomical references J. Pascau a,b, M. Desco a,

More information

Est-ce que l'eeg a toujours sa place en 2019?

Est-ce que l'eeg a toujours sa place en 2019? Est-ce que l'eeg a toujours sa place en 2019? Thomas Bast Epilepsy Center Kork, Germany Does EEG still play a role in 2019? What a question 7T-MRI, fmri, DTI, MEG, SISCOM, Of ieeg course! /HFO, Genetics

More information

In press at Brain Topography; accepted June 2010

In press at Brain Topography; accepted June 2010 In press at Brain Topography; accepted June 2010 Does high-frequency repetitive transcranial magnetic stimulation produce residual and/or cumulative effects within an experimental session? Massihullah

More information

Effects of Short-Term Repetitive Transcranial Magnetic Stimulation on P300 Latency in an Auditory Odd-Ball Task

Effects of Short-Term Repetitive Transcranial Magnetic Stimulation on P300 Latency in an Auditory Odd-Ball Task 28 INTERNATIONNAL JOURNAL OF APPLIED BIOMEDICAL ENGINEERING VOL.5, NO.1 2012 Effects of Short-Term Repetitive Transcranial Magnetic Stimulation on P300 Latency in an Auditory Odd-Ball Task Tetsuya Torii

More information

Detection and Plotting Real Time Brain Waves

Detection and Plotting Real Time Brain Waves Detection and Plotting Real Time Brain Waves Prof. M. M. PAL ME (ESC(CS) Department Of Computer Engineering Suresh Deshmukh College Of Engineering, Wardha Abstract - The human brain, either is in the state

More information

Intrinsic Signal Optical Imaging

Intrinsic Signal Optical Imaging Intrinsic Signal Optical Imaging Introduction Intrinsic signal optical imaging (ISOI) is a technique used to map dynamics in single cells, brain slices and even and most importantly entire mammalian brains.

More information

Off-line removal of TMS-induced artifacts on human. electroencephalography by Kalman filter

Off-line removal of TMS-induced artifacts on human. electroencephalography by Kalman filter Off-line removal of TMS-induced artifacts on human electroencephalography by Kalman filter F. Morbidi a, A. Garulli a, D. Prattichizzo a, C. Rizzo b, P. Manganotti c, S. Rossi d a Department of Information

More information

COGNITIVE SCIENCE 17. Peeking Inside The Head. Part 1. Jaime A. Pineda, Ph.D.

COGNITIVE SCIENCE 17. Peeking Inside The Head. Part 1. Jaime A. Pineda, Ph.D. COGNITIVE SCIENCE 17 Peeking Inside The Head Part 1 Jaime A. Pineda, Ph.D. Imaging The Living Brain! Computed Tomography (CT)! Magnetic Resonance Imaging (MRI)! Positron Emission Tomography (PET)! Functional

More information

FREQUENCY DOMAIN BASED AUTOMATIC EKG ARTIFACT

FREQUENCY DOMAIN BASED AUTOMATIC EKG ARTIFACT FREQUENCY DOMAIN BASED AUTOMATIC EKG ARTIFACT REMOVAL FROM EEG DATA features FOR BRAIN such as entropy COMPUTER and kurtosis for INTERFACING artifact rejection. V. Viknesh B.E.,(M.E) - Lord Jeganath College

More information

Development of a New Rehabilitation System Based on a Brain-Computer Interface Using Near-Infrared Spectroscopy

Development of a New Rehabilitation System Based on a Brain-Computer Interface Using Near-Infrared Spectroscopy Development of a New Rehabilitation System Based on a Brain-Computer Interface Using Near-Infrared Spectroscopy Takafumi Nagaoka, Kaoru Sakatani, Takayuki Awano, Noriaki Yokose, Tatsuya Hoshino, Yoshihiro

More information

Electronically Switchable Sham Transcranial Magnetic Stimulation (TMS) System

Electronically Switchable Sham Transcranial Magnetic Stimulation (TMS) System Electronically Switchable Sham Transcranial Magnetic Stimulation (TMS) System Fumiko Hoeft 1,2 *, Daw-An Wu 2,3, Arvel Hernandez 1, Gary H. Glover 4, Shinsuke Shimojo 2 1 Center for Interdisciplinary Brain

More information

TREATMENT-SPECIFIC ABNORMAL SYNAPTIC PLASTICITY IN EARLY PARKINSON S DISEASE

TREATMENT-SPECIFIC ABNORMAL SYNAPTIC PLASTICITY IN EARLY PARKINSON S DISEASE TREATMENT-SPECIFIC ABNORMAL SYNAPTIC PLASTICITY IN EARLY PARKINSON S DISEASE Angel Lago-Rodriguez 1, Binith Cheeran 2 and Miguel Fernández-Del-Olmo 3 1. Prism Lab, Behavioural Brain Sciences, School of

More information

Supplemental Material

Supplemental Material Supplemental Material Recording technique Multi-unit activity (MUA) was recorded from electrodes that were chronically implanted (Teflon-coated platinum-iridium wires) in the primary visual cortex representing

More information

Toward a more accurate delimitation of the epileptic focus from a surgical perspective

Toward a more accurate delimitation of the epileptic focus from a surgical perspective Toward a more accurate delimitation of the epileptic focus from a surgical perspective Margitta Seeck Department of Clinical Neurosciences EEG & Epilepsy Unit University Hospital of Geneva Geneva, Switzerland

More information

Chapter 5 The Research Methods of Biopsychology

Chapter 5 The Research Methods of Biopsychology Chapter 5 The Research Methods of Biopsychology Understanding What Biopsychologists Do This multimedia product and its contents are protected under copyright law. The following are prohibited by law: any

More information

The impact of numeration on visual attention during a psychophysical task; An ERP study

The impact of numeration on visual attention during a psychophysical task; An ERP study The impact of numeration on visual attention during a psychophysical task; An ERP study Armita Faghani Jadidi, Raheleh Davoodi, Mohammad Hassan Moradi Department of Biomedical Engineering Amirkabir University

More information

Neurostyle. Medical Innovation for Better Life

Neurostyle. Medical Innovation for Better Life Neurostyle Medical Innovation for Better Life Neurostyle Pte Ltd is a company dedicated to design, develop, manufacture and distribute neurological and neuromuscular medical devices. Strategically located

More information

EEG SPIKE CLASSIFICATION WITH TEMPLATE MATCHING ALGORITHM. Çamlık Caddesi No:44 Sarnıç Beldesi İZMİR 2 Elektrik ve Elektronik Müh.

EEG SPIKE CLASSIFICATION WITH TEMPLATE MATCHING ALGORITHM. Çamlık Caddesi No:44 Sarnıç Beldesi İZMİR 2 Elektrik ve Elektronik Müh. EEG SPIKE CLASSIFICATION WITH TEMPLATE MATCHING ALGORITHM Selim BÖLGEN 1 Gülden KÖKTÜRK 2 1 Pagetel Sistem Müh. San. Tic. Ltd. Şti. Çamlık Caddesi No:44 Sarnıç Beldesi İZMİR 2 Elektrik ve Elektronik Müh.

More information

CSE 599E Introduction to Brain-Computer Interfacing

CSE 599E Introduction to Brain-Computer Interfacing CSE 599E Introduction to Brain-Computer Interfacing Instructor: Rajesh Rao TA: Sam Sudar The Matrix (1999) Firefox(1982) Brainstorm (1983) Spiderman 2 (2004) Hollywood fantasy apart, why would we want

More information

Clinically Available Optical Topography System

Clinically Available Optical Topography System Clinically Available Optical Topography System Clinically Available Optical Topography System 18 Fumio Kawaguchi Noriyoshi Ichikawa Noriyuki Fujiwara Yûichi Yamashita Shingo Kawasaki OVERVIEW: Progress

More information

Seizure onset can be difficult to asses in scalp EEG. However, some tools can be used to increase the seizure onset activity over the EEG background:

Seizure onset can be difficult to asses in scalp EEG. However, some tools can be used to increase the seizure onset activity over the EEG background: This presentation was given during the Dianalund Summer School on EEG and Epilepsy, July 24, 2012. The main purpose of this introductory talk is to show the possibilities of improved seizure onset analysis

More information

WAVELET ENERGY DISTRIBUTIONS OF P300 EVENT-RELATED POTENTIALS FOR WORKING MEMORY PERFORMANCE IN CHILDREN

WAVELET ENERGY DISTRIBUTIONS OF P300 EVENT-RELATED POTENTIALS FOR WORKING MEMORY PERFORMANCE IN CHILDREN WAVELET ENERGY DISTRIBUTIONS OF P300 EVENT-RELATED POTENTIALS FOR WORKING MEMORY PERFORMANCE IN CHILDREN Siti Zubaidah Mohd Tumari and Rubita Sudirman Department of Electronic and Computer Engineering,

More information

Maturation of corticospinal tracts assessed by electromagnetic stimulation of the motor cortex

Maturation of corticospinal tracts assessed by electromagnetic stimulation of the motor cortex Archives of Disease in Childhood, 1988, 63, 1347-1352 Maturation of corticospinal tracts assessed by electromagnetic stimulation of the motor cortex T H H G KOH AND J A EYRE Department of Child Health,

More information