Evidence of the efficacy and safety of the thulium laser in the treatment of men with benign prostatic obstruction

Size: px
Start display at page:

Download "Evidence of the efficacy and safety of the thulium laser in the treatment of men with benign prostatic obstruction"

Transcription

1 632429TAU / Therapeutic Advances in UrologyY. Barbalat et al. research-article2016 Therapeutic Advances in Urology Review Evidence of the efficacy and safety of the thulium laser in the treatment of men with benign prostatic obstruction Yana Barbalat, Marissa C. Velez, Christopher I. Sayegh and Doreen E. Chung Ther Adv Urol 2016, Vol. 8(3) DOI: / The Author(s), Reprints and permissions: journalspermissions.nav Abstract: In 2005, the high power thulium laser was introduced for the surgical treatment of benign prostatic obstruction. It has several properties that confer theoretical advantages over other lasers used for the same indication, such as technical versatility and a relatively small zone of thermal damage. Studies using the W thulium laser systems demonstrate good efficacy of these procedures with low morbidity and few complications even in higher risk patients. Different techniques have been employed to treat the prostate with this technology, including enucleation, vapoenucleation, vaporization and resection. Comparative studies have been published comparing thulium laser prostatectomy to monopolar transurethral resection of prostate (), bipolar and holmium laser enucleation of prostate (HoLEP). In this review we discuss the current literature on the safety and efficacy of various thulium techniques for the treatment of benign prostatic hyperplasia and examine comparative studies. Keywords: laser therapy, prostatic hyperplasia, thulium Introduction According to the Urologic Diseases in America project, benign prostatic hyperplasia (BPH) affects 70% of men in the US aged and 80% of those aged 70 or older [Wei et al. 2005]. The Rancho Bernardo study, a longitudinal population-based study, found that 56% of men aged 50 79, 70% of men aged and 90% of men aged 90 or older reported experiencing lower urinary tract symptoms (LUTS) [Parsons et al. 2008]. Multiple surgical options are available for the treatment of BPH and its associated symptoms, with transurethral resection of the prostate () remaining the gold standard surgical treatment with the longest follow-up data available. Although traditional is both efficient and effective, it is associated with significant morbidity from bleeding and fluid shifts, including a 2 8% transfusion rate [Mebust et al. 1989; Rassweiler et al. 2006]. rates have declined over the past two decades due to the significant benefits of medical therapy and the proliferation of alternative surgical techniques that include laser therapies for BPH. Yu and colleagues analyzed practice patterns and found that, by 2005, traditional accounted for 39% of surgical interventions for BPH while laser procedures accounted for 57% [Yu et al. 2008]. There are several different types of minimally invasive laser procedures including enucleation, vaporization, vapoenucleation and resection. The high power thulium laser was first introduced in 2005 for the treatment of BPH [Xia et al. 2005]. Similar to holmium technology, at 2010 nm, the wavelength of the thulium laser is very close to the peak for absorption in water, which is 1940 nm. However, unlike the pulsed wave holmium laser, this high density energy is delivered in a continuous wave. This theoretically translates to more efficient vaporization and shallower depth of penetration in tissue, which has been reported to be 0.2 mm as compared with 0.4 mm for holmium lasers [Fried and Murray, 2005]. This property likely also results in a smaller zone of thermal damage, which in turn may help to decrease postoperative dysuria, an adverse effect that is commonly associated with Correspondence to: Doreen E. Chung, MD Columbia University Medical Center, 161 Fort Washington Avenue, HIP 11th Floor, New York, NY 10032, USA dec2154@cumc.columbia. edu Yana Barbalat, MD Marissa C. Velez, MD Christopher I. Sayegh, BSc Columbia University Medical Center, New York, NY, USA 181

2 Therapeutic Advances in Urology 8(3) transurethral laser prostate surgery [Rieken et al. 2010]. The fiber is diode pumped which gives it the capability of operating in either a pulsed mode or a continuous wave mode. The continuous wave mode is more suitable for hemostasis and coagulation of tissue, whereas the pulsed mode for is more suited for lithotripsy [Hardy et al. 2014]. Studies using the W thulium laser systems demonstrate good short-term efficacy with low morbidity and few complications [Gross et al. 2012]. This paper reviews the current evidence of safety and efficacy of the various thulium laser techniques for the treatment of BPH and the comparative studies. Methods A PubMed search for papers from 2005 to 2015 was conducted using the words thulium laser prostate. A total of 112 papers were obtained. After case reports, abstracts only and papers not in English were excluded, 98 articles remained. We reviewed all case series, review papers, cohort studies, and retrospective and prospective studies relevant to the topic covered in this review. We then scanned the references of the articles used to capture any additional relevant papers which would make this manuscript more comprehensive. Surgical techniques Several techniques using the thulium laser have been described for laser prostatectomy including thulium vapoenucleation (ThuVEP) and thulium laser resection of the prostate () (the tangerine technique), thulium laser enucleation (ThuLEP) and thulium vaporization (ThuVP) (Table 1). In the authors opinion, for smaller prostates all techniques are similarly efficient and feasible. The end-fire fiber in combination with effective vaporization of the thulium laser system lends itself to both vaporization and enucleation. Hence, the choice of technique in smaller prostates is mostly driven by surgeon preference. For larger prostates (i.e. size >100 ml), enucleation techniques are more efficient and effective. ThuVEP and ThuLEP are almost identical techniques in description. There may be a greater proportion of mechanical, as opposed to laser, enucleation in the ThuLEP technique. There are two main high power thulium laser systems: the Cyber TM (Quanta System, Solbiate Olona, Italy; 150W, 200W) and the Revolix (Lisa Laser, Katlenburg-Lindau, Germany; 30W, 70W, 120W and 200W systems). The authors have used both systems at the same power level and there does not appear to be a noticeable in vaporization efficiency. Vapoenucleation (ThuVEP) Vapoenucleation is the most commonly described technique and involves trilobar enucleation using a combination of laser and mechanical energy followed by intravesical morcellation, similar to holmium laser enucleation of prostate (HoLEP) [Bach et al. 2009a, 2009b]. The continuous wave of the thulium laser leads to a very different interaction with prostate tissue compared with the pulsed holmium laser, which is the reason the technique has been coined vapoenucleation. The majority of studies are short term and there is large heterogeneity in patient populations making the studies difficult to compare. The first studies were performed in small prostates where the tissue chip size was small enough to avoid the need for morcellation. Bach and colleagues reported on a single surgeon feasibility series of 54 men with a mean prostate volume 30.3 (range 12 38) cm 3 who underwent vaporesection of the prostate with the 70W RevoLix (Lisa Laser Products, Katlenburg-Lindau, Germany) laser system with a wavelength of 2013 nm [Bach et al. 2007]. Improvements were seen in mean International Prostate Symptom Score (IPSS) (19.8 to 6.9), maximum flow rate (Qmax) ( ml/s) and postvoid residual (PVR) (86 12 ml) compared with preoperative paramaters. No patients required transfusion or rehospitalization. A total of six (11%) patients developed a symptomatic urinary tract infection (UTI) requiring antibiotic therapy. Following this feasibility study, this same group of authors investigated the feasibility and efficacy of thulium:yag (Tm:YAG) laser vapoenucleation of the prostate in larger prostates [Bach et al. 2009b]. In this short-term study, with follow up to discharge, 88 patients with a prostate volume of 61.3 ± 24.0 cm 3 underwent vapoenucleation of the prostate with the 70W RevoLix Tm:YAG laser. In contrast to the previous study, morcellation was performed in all patients following enucleation. The complication rate was 16.6%, with 12 patients having complications: two (2.2%) patients required blood transfusions for 182

3 Y Barbalat, MC Velez et al. Table 1. Thulium non-comparative observational studies. Reference Thulium technique No. of patients Mean prostate size (g) Operative time (min) Anticoagulation (% patients) Follow up (months) Complications Iacono et al. [2012] Rausch et al. [2015] Gross et al. [2012] Netsch et al. [2013] Sun et al. [2015] Pariser et al. [2014] Vargas et al. [2014] ThuLEP ± ± N/A 12 UTI (12.8%) Bladder injury (2.7%) (2.7%) ThuLEP ± ± 37 ASA/clopidogrel held (except for high risk patients) (5.1%) 24 UTI (3%) (0.9%) Stricture (2.1%) ThuVEP * 56 (40-80) Continued (28.7%) 1 UTI (8.4%) (1.7%) ThuVEP 56 50* 61.5 ( ) Continued (100%) 24 (7.1%) * 64 (48 85) Continued (10.3%) 8 year UTI (3.1%) (0.6%) ThuVP ± ± 18 (laser time) Warfarin bridged to enoxaparin or heparin. ASA/ clopidogrel held or continued based on cardiology recommendation. (47%) 3 UTI (10%) (0%) ThuVP ± ± Excluded 6 UTI (3.6%) (0%) *Reported as median value. ASA, acetylsalicylic acid; ThuLEP, thulium laser enucleation; ThuVP, thulium vaporization;, thulium laser resection of the prostate; UTI, urinary tract infection. postoperative bleeding; six (6.8%) patients developed symptomatic UTIs; three (3.4%) patients experienced intra- or postoperative bleeding; and two (2.2%) underwent a second-look procedure during the same hospital stay due to inability to void. Significant improvements were seen at discharge in Qmax (3.5 ± ± 11.6 ml/s) and PVR (121 ± ± 33 ml). This same group reported on complications and early postoperative outcomes of ThuVEP performed by 11 surgeons at a single institution in an impressively large series of 1080 patients using various generations of the thulium laser between 70W and 200W [Gross et al. 2012]. This was a short-term analysis examining preoperative characteristics, surgical details and immediate outcomes. Median age at surgery was 71 years and prostate size was 52 ml [interquartile range (IQR) 36 79] with a median operation time of 56 minutes. A total of 22% of patients were in retention prior to surgery. Median enucleation time was 33 minutes (IQR 22 50) and median resected tissue weight was 30 g (IQR 36 78). Significant changes were seen after surgery in median maximum flow rate ( ml/s, p < 0.001) and PVR ( ml, p < 0.001) compared with before surgery. Median catheterization time was 2 days (IQR 2 2) and median hospital stay was 4 days (IQR 3 5). The overall immediate morbidity rate was 16.9%. Minor complications (Clavien class 1 and 2) occurred in 262 (24.6%) patients. Within 4 weeks, 71 (6.6%) patients required intervention 183

4 Therapeutic Advances in Urology 8(3) (Clavien 3a: 0.6%; Clavien 3b: 6%). One patient had a Clavien 4a complication and had an acute myocardial infarction. No mortalities were seen. The most frequently reported complications were urinary retention after catheter removal (9%), UTI without bacteremia (6.9%), clot retention without surgical revision (3.5%), residual prostate tissue requiring reoperation (2.7%), capsular perforation (2.1%), hemorrhage requiring reoperation (2%), bleeding requiring blood transfusion (1.7%), UTI with signs of bacteremia (1.5%), extraperitoneal fluid collection (1.5%), superficial bladder injury due to morcellation (1.4%), ureteral orifice injury (0.7%) and hydronephrosis due to ureteric orifice injury (0.6%). The overall reoperation rate was 4.7% and the readmission rate was 4.1%. A subanalysis was performed and patients were stratified by prostate size. Group A had a prostate size <40 ml (28%), Group B had a prostate size ml (47%) and Group C had a prostate size 80 ml (25%). No s were seen in complications rates between the groups. The complication rate using the Clavien classification system (CCS) were then compared with those in published series of HoLEP, photoselective vaporization of the prostate (PVP), and open prostatectomy. Overall in this large series, immediate outcomes and complication rates for ThuVEP were similar to those in large series of HoLEP and PVP and lower than in and open prostatectomy. This large series confirmed that ThuVEP is a safe and effective procedure for the treatment of symptomatic BPH with low perioperative morbidity. There are many strengths of this large series of patients including adequate power, multiple surgeons and use of standardized reporting methods for complications. However, the fact that it was a single center study and that various generations of the thulium laser were used may not make the results generalizable to some populations. Studies support the use of ThuVEP in medically complex patients, such as high risk cardiopulmonary patients on oral anticoagulation, with few perioperative complications. Macchione and colleagues investigated the safety and efficacy of ThVEP using the 120-W Tm:YAG laser (Revolix Duo) in 76 patients who were taking oral antiplatelet or anticoagulation. In 41 patients (group A), the procedure was performed while patients continued oral anticoagulation and, in 35 patients (group B), oral anticoagulation was discontinued 10 days prior to surgery and patients were bridged with low molecular weight heparin (LMWH) for 2 weeks, with 3 (8%) patients from this group taking warfarin [Macchione et al. 2013]. In group A, 5 (12%) patients were taking warfarin, 20 (48%) acetylsalicylic acid (ASA), 12 (29%) ticlopidine, and 4 (10%) ASA and clopidogrel. In group B, 3 (8%) patients were taking warfarin, 15 (42%) ASA, 11 (31%) ticlopidine and 6 (17%) ASA and clopidogrel. All procedures were performed by a single surgeon. The decision to discontinue oral anticoagulation was made by the consultant cardiologist. In both groups, mean age was similar (69 ± 7 for both) as well as mean prostate size (65 ml for both). Median ASA for both groups was 3. Operative times (48 ± 8, 47 ± 5 minutes), catherization time (1.5 ± 6, 1.6 ± 6 days), hospital stay (2.3 ± 0.9 and 2.4 ± 9 days), mean drop in sodium (0.52 ± 2.0 and 1.34 ± 1.1 g/l) and mean hemoglobin drop (0.35 ± 0.2 and 0.85 ± 0.2 g/l) were similar between groups A and B. Only one patient in group A required a transfusion. A total of three (4%) patients overall required continuous bladder irrigation for postoperative hematuria. Significant improvements were seen compared to baseline in Qmax, IPSS, PVR and quality of life (QoL) at 3 and 6 months postoperative. Thulium laser resection of prostate () was initially applied in 2004 by Xia and colleagues in the treatment of BPH [Xia et al. 2005]. Described as the tangerine technique, resection is carried out by dissection of whole prostatic lobes off the surgical capsule similar to that of peeling a tangerine. Tissue is vaporized sufficiently so that small pieces may be removed via a resectoscope without requiring use of a morcellator [Xia, 2009]. Several studies with shortterm follow up have demonstrated excellent safety and efficacy of this technique [Xia et al. 2008; Fu et al. 2010]. In 2014, Sun and colleagues evaluated the longterm durability and complication rates after through a large, prospective, multicenter study [Sun et al. 2015]. A total of 2016 patients were treated with at four medical centers and were followed for up to 8 years (61.1% followed for 5 years, 24.4% followed for 8 years). A 184

5 Y Barbalat, MC Velez et al. Tm:YAG laser was used with a laser power level at 50W, 70W or 120W in all patients. IPSS, QoL, Qmax and PVR were all significantly improved at 3 months after surgery and remained significantly improved during the entire follow-up period. IPSS and QoL decreased by 72.3% and 75%, respectively; Qmax had increased by 178% and PVR had decreased by 81.8% by the end of follow up. At 3 months, 1 year and 8 years postoperatively, median IPSS was 7, 6 and 6, respectively; median QoL was 1, 1 and 1; median Qmax was 21.7, 22.3 and 19.2 ml/s, respectively; and PVR was 22, 18 and 20 ml. These results showed sustained long-term improvement in all urinary parameters post. Short-term Clavien 1 and 2 complications occurred in 23.7% of the patients. A total of 9% patients had some type of temporary urinary incontinence and only 3% of patients were reported to have UTI. A total of 6% of patients went into urinary retention requiring catheterization and 3% had clot retention requiring bladder irrigation. Blood transfusion was required by 13 (0.6%) patients and eight (0.4%) developed deep vein thrombosis and pulmonary embolus. There was evidence of systemic infection in 29 (1.3%) patients. Clavien 3 complications, requiring re-intervention occurred in 2.2% of the patients. Resection of residual tissue was required in 11 (0.5%) patients and 37 (1.7%) patients underwent cystoscopy for bleeding. In the cohort of 556 patients with prostate size >80 g, there was no in overall, Clavien 1, 2 or 3 complications compared with the patients with prostate size <80 g. One unique aspect of this study was the reporting of long-term complications. Urethral stricture and bladder neck contractures occurred in 2.6% and 1.6% of patient, respectively. Persistent stress incontinence was found in two patients (0.1%). Re-operation as a result of BPH recurrence was required in 1.2% of patients over the course of up to 8 years. Of note, this study also included 228 patients who were taking oral anticoagulants (aspirin and/ or clopidogrel) at the time of surgery. There was no in overall, Clavien 1, 2 or 3 complications between those taking anticoagulants and not. Additionally, there was no in perioperative bleeding between the two groups (1.3% risk on anticoagulation 0.7% risk off anticoagulation, p = 0.41) This study offers a particular robust analysis given its prospective, multi-centered design, long-term follow up and inclusion of a diverse patient profile including varied prostate size and patients at higher risk of cardiopulmonary or bleeding complications than those on anticoagulation. Thulium laser vaporization of the prostate (ThuVP) Although the thulium laser is well suited to vaporization, it is only recently that the safety and efficacy of ThuVP has been reported. Pariser and colleagues reported short-term outcomes of ThuVP using the 150W (Cyber ) thulium laser in the US, which was the first study to be published on outcomes on any technique for thulium laser prostatectomy in a North American patient population. A total of 59 patients with mean prostate volume of 57 ± 30.2 ml underwent ThuVP; 47% of the patients were taking oral anticoagulation at baseline with aspirin, clopidogrel, warfarin or enoxaparin. The majority (78%) of patients were discharged home the same day of surgery. Although there was a significant change in hemoglobin from baseline ( g/dl), no patients received blood transfusions and the drop was similar to that seen in 532 nm laser studies [Pariser et al. 2014]. At 3 months, mean Qmax and PVR were significantly improved. Subjective measurements (IPSS and QoL) also demonstrated significant improvements from baseline at all follow-up intervals. At 3 months, IPSS was 8.7 ± 6.5 compared with 19.9 ± 8.0 at baseline and QoL was 2.1 ± 1.4 compared with 4.5 ± 1.1 at baseline (p < 0.05). All 15 patients who presented in retention were voiding spontaneously at the time of their last follow up. The overall 30-day complication rate was 20%, with all complications graded as Clavien 1 and 2. A total of 10% of patients needed catheterization for urinary retention (half of these were in retention prior to surgery) and 10% developed symptomatic culture-proven UTIs. There were no immediate higher grade complications. Between 30 and 90 days, 1 patient developed a urethral stricture and 1 a bladder neck contracture. Both were successfully managed endoscopically and represent the only Clavien grade 3 complications [Pariser et al. 2014]. Around the same time, Vargas and colleagues also published outcomes of 150W ThuVP with 6 months of follow up in 52 patients in Spain

6 Therapeutic Advances in Urology 8(3) Prostate size was comparatively smaller with median 51 ml (IQR ml) and patients on anticoagulation were excluded. Patients were also discharged home the same day of surgery. Significant improvements were seen in Qmax (mean improvement 9.33 ml/s) and mean IPSS (reduction by 17 points). Immediate complications were recorded at 1 month follow up and included acute urinary retention (one patient), urinary tract infection (two patients) and gross hematuria (two patients). The only late complication observed (assessed at the 6 month mark) was bladder neck contracture, which was seen in one patient. Again within 30 days, no Clavien grade 3 or higher complications were seen [Vargas et al. 2014]. No comparative data are available for ThuVP, although this technique appears to have short-term complications similar to those described after vaporization with other laser systems as well as [Reich et al. 2008; Pereira- Correia et al. 2012]. Thus far, early short-term studies on ThuVP appear promising and outcomes appear similar to those from 532 nm vaporization but further longterm and comparative studies are needed. Thulium laser enucleation of the prostate (ThuLEP) ThuLEP is extremely similar to ThuVEP except that enucleation of the adenoma is done mechanically without the use of energy. The initial cuts are still made with the laser [Kyriazis et al. 2012]. Due to the continuous pulse, vaporization occurs whenever the laser is employed. Indeed, in papers the description between the two techniques is often indistinguishable [Bach et al. 2009a, 2009b]. Iacono and colleagues described a series of 148 men who underwent ThuLEP with large prostate size (108 ± 24 ml) who underwent the procedure using the 120W RevoLix laser with 12 months of follow-up. Significant improvements were seen in IPSS, QoL, and PVR [Iacono et al. 2012]. Complications included UTI in 19 patients (12.8%), postoperative urgency incontinence in 10 (6.7%), early recatheterization with residual tissue at prostatic apex in four patients (2.7%), blood transfusion in four patients (2.7%) and bladder injury during morcellation in 2 patients (1.3%). There was significant increase in IIEF but the absolute in score was very small (19.3 ± ± 8.2, p < 0.05). In a recent series, Rausch and colleagues performed ThuLEP between 2008 and 2012 in 234 patients with a mean prostate size of 84.8 ± 34.9 ml using the RevoLix (power not specified). Overall the 30-day complication rate was 19.7%. In the perioperative period, only 3% of patients experienced a UTI, 6.8% required catheter replacement and 0.9% required a blood transfusion. In the postoperative period, 3% experienced urgency incontinence and 2.1% experienced bladder neck stricture [Rausch et al. 2015]. Complications occurring after 30 days included stress incontinence in one patient (0.5%) and inability to void requiring chronic catheterization in 19 (8.1%) patients. Predictors of complications in univariate and multivariate analysis were age >80 years and prostate size <50 ml. Very few studies have addressed sexual outcomes in detail following any thulium laser prostatectomy. In 2015, Carmignani and colleagues evaluated sexual outcomes in 110 men undergoing ThuLEP with the Cyber 150 W laser in a prospective study using validated instruments. Patients were evaluated before surgery and at 3 and 6 months after ThuLEP with IPSS, IIEF-5 and ICIQ-Male Sexual Matters associated with Lower Urinary Tract Symptoms (ICIQ- MLUTSsex) [Carmignani et al. 2015]. While a significant and sustained improvement in the scores evaluating urinary symptoms was observed, there were no significant s in erectile function before and after surgery. Comparative studies Comparative studies to traditional Several comparative studies of thulium laser prostatectomy and other transurethral techniques are available (see Table 2), mostly originating in Asia. Several studies have been published comparing thulium laser prostatectomy with standard monopolar [Xia et al. 2008]. Using a 50W continuous wave thulium laser (LISA Laser Products OHG, Germany), Xia and colleagues performed and compared outcomes up to 12 months with standard. Patients in urinary retention were excluded. A total of 52 patients were randomized to and 48 to. Operative time for both procedures were also similar for and (46 ± 16 and 50 ± 20 minutes, p = 0.28). There was a smaller decrease in hemoglobin in the group (0.92 ± ± 0.65 g/dl, 186

7 Y Barbalat, MC Velez et al. Table 2. Comparative studies. Reference Thulium techniques compared Study design No. of patients Prostate size (g) Mean prostate size (g) Follow up Complications Operative time Hospital stay Hemoglobin decrease (g/dl) Xia et al. [2008] Cui et al. [2014] Chang et al. [2015] Yang et al. [2013] Wei et al. [2014] Peng et al. [2013] Traditional traditional ThuVEP Traditional ThuLEP Randomized prospective trial Randomized prospective trial Prospective, nonrandomized Randomized prospective trial Randomized prospective trial Randomized prospective trial 100 < ± month No significant 55.1 ± < ± 23.2 All 4 year No significant 48 ± ± Any 57.2 ± 25.1 ThuVEP 64.7 ± < ± 21.2 ThuLEP 69.2 ± > ± ± Any 57.8 ± month ThuVEP 13.8% 26.7% 18 month No significant 18 month : Clavien 1: %; Clavien 2: %; Clavien 3: 0 0% 3 month No significant No significant ± 25.5 hours ± 33.8 hours (p < ) 0.92 ± ± 0.65 (p = ) Unknown Unknown Unknown Unknown No significant ThuLEP 65.4 ± 22.2 m 47.4 ± 15.9 m (p = 0.022) No significant 61.2 ± 24.2 m ± 5.9 m (p < 0.05) ThuLEP 2.5 ± 1.4 days 4.6 ± 1.4 days (p = 0.026) 3.8 ± 0.46 days 5.02 ± 0.54 days (p < ) 3.3 ± 0.8 days 4.1 ± 1.3 days (p < 0.05) No significant ThuLEP 0.15 ± ± 0.03 (p = 0.045) 0.86 ± ± 1.04 (p = 0.006) No significant, bipolar transurethral resection of the prostrate; ThuLEP, thulium laser enucleation; ThuLRP, thulium laser resection of the prostate; ThuVEP, thulium vapoenucleation;, transurethral resection of the prostate

8 Therapeutic Advances in Urology 8(3) p = ). Hospital stay (115 ± ± 34 hours, p < ) and catheterization time (46 ± 26 and 87 ± 34 hours, p < ) were also shorter in the group compared with. At 1, 6 and 12 months follow up, no significant s were seen between groups in IPSS, QoL, Qmax or PVR. No significant changes in IIEF-5 scores were seen compared with preoperative in either group [Xia et al. 2008]. Regarding adverse effects, there were two (4%) transfusions required in the group but none required in the group. No significant s were found with regard to rate of transfusion, syndrome or UTI. No s were seen in either the rate of de novo stress urinary incontinence or urethral strictures. Overall, this study suggested that subjective and objective improvements of this technique are similar to but with lower morbidity. More recently, Cui and colleagues performed a randomized trial comparing the safety and efficacy of standard compared with with outcomes to 4 years. Patients were randomized to the (49)and (57) groups. The authors found that the degree of improvement in all micturition parameters including IPSS, QoL, PVR and Qmax were near comparable in both the and the patients at every time point of follow up to 48 months. Details of the short-term complications were not reported. Long-term re-operation rates for BPH recurrence and rate of bladder neck contracture were similar in the two groups, although the study may be underpowered to look at these parameters [Cui et al. 2014]. Chang and colleagues recently reported a study that compared a high-power 150W CyberTM ThuVEP with standard with a 1-year follow up. A total of 29 patients were assigned to have ThuVEP and 30 to. Voided volume, Qmax, PVR and mean flow rate all improved significantly in both groups and there were no s in IPSS or QoL after 1 year of follow up. The transfusion rate in this study was 13.8% in the ThuVEP group and 26.7% in the group, which is higher than that reported in other studies using the high power laser [Gross et al. 2012; Pariser et al. 2014]. This may be due to a lower threshold for transfusion in the older patient population of this study (mean age: ThuVEP 76; 72). There was minimal change in hemoglobin level before and after the operation (ThuVEP: 0.5 ± 1.3 g/dl; : 0.5 ± 1.1 g/dl) [Chang et al. 2015]. Because operative time was not reported and baseline patient characteristics are very different to those in the previous studies, it is difficult to make a conclusion in regard to the benefit of the higher power laser compared with the 50W laser used by Xia and colleagues in A meta-analysis using nine trials to examine the performance of indicated to be a safe, feasible and efficient alternative to for treating patients with BPH with reliable perioperative safety, fewer complications, and comparable efficacy in relation to Qmax, PVP, QoL and IPSS. Patients undergoing experienced smaller declines in serum sodium levels (p < ), hemoglobin levels (p < ), shorter durations of catheterization (p < ), shorter lengths of hospital stay (p < ) and fewer total complications (p < ) [Tang et al. 2014]. Comparative studies to bipolar transurethral plasmakinetic prostatectomy () Yang and colleagues published a comparative study of 158 patients randomized to ThuLEP with a 100W thulium laser and, with all patients returning for 18-month follow up. Preoperative parameters were similar in both groups. The authors found that ThuLEP required a significantly longer operative time ( minutes, p = 0.022) than, but resulted in a significantly shorter hospital stay ( days, p = 0.026), shorter catheterization time ( days, p = 0.031) and lower drop in hemoglobin ( g/dl). Similar improvements were seen in IPSS, QoL, Qmax and PVR [Yang et al. 2013]. Short-term and perioperative complications were not mentioned. No patients in any group developed urethral strictures or bladder neck contractures. Wei and colleagues compared the efficacy and safety of using the 120W Tm:YAG laser to in patients with prostate size >80 g. A total of 45 patients were randomized to each group and were evaluated at 1, 6, 12 and 18 months. The mean prostate sizes ( ± ml, 115 ± ml group) as well as other perioperative parameters were similar in both groups. Compared with the group, the group had statistically lower hemoglobin drop, shorter catheterization time and shorter hospital stay. Both groups had significant postoperative improvements in IPSS, QoL, Qmax and PVR, 188

9 Y Barbalat, MC Velez et al. with no s observed between the two groups. Both techniques showed a low perioperative complication rate ( : Clavien 1: %; Clavien 2: %; Clavien 3: 0 0%). One patient in the group required a blood transfusion perioperatively. Urethral stricture rate was equal (one patient in each group) and one patient in group developed a bladder neck contracture. Additionally, there were no significant reduction in IIEF-5 scores during the follow-up period compared with preoperative data and no statistically significant was observed between the two groups [Wei et al. 2014]. Peng and colleagues also sought to compare the short-term efficacy and safety of with a 100W thulium laser (LISA Laser products OHG, Germany) to. A total of 100 patients were randomized to or. Operative time was significantly longer in the group (61 ± ± 6 minutes, p < 0.05), while catheterization time (1.8 ± ± 0.6 days, p < 0.05) and hospital stay (3.3 ± ± 1.3 days, p < 0.05) were significantly shorter. No transfusions were required in either group. Significant improvements were seen in both groups in subjective and objective objectives at 1 and 3 months postoperative. Short-term and perioperative complications were not mentioned. Compared with, was superior in safety, blood loss and urethral stricture rate with similar improvements in IPSS, Qmax and PVR [Peng et al. 2013]. Comparative studies to HoLEP Zhang and colleagues randomized 133 consecutive patients with BPH to either undergo ThuLEP or HoLEP in order to compare the two techniques. They used a 70W thulium laser system and a 100W holmium laser system and randomized 72 patients to the thulium group and 62 patients to the holmium group. For the ThuLEP and HoLEP groups, mean prostate volume was relatively small and similar (47 ± 25 and 44 ± 23 ml). Operative time was comparatively longer for the ThuLEP group the HoLEP group ( minutes), but resulted in less blood loss (130.0 ml ml). However, catheterization time and decrease in hemoglobin postoperatively were similar in both groups. The authors concluded that the shorter operative time of the HoLEP may be secondary to the ease of finding the correct capsular plane with the holium:yag laser. The physical characters of the pulsed holmium:yag laser include a scar-free feature on the prostatic surface with precise incision and dissection simultaneous with coagulation of small and medium-size vessels. Hence, as the incision reaches the surgical capsule, the transitional prostatic lobes burst from this plane to make the enucleation easier. In contrast, the thulium:yag laser energy is emitted in a continuous wave and induces an eschar-like effect on the surface of the incised tissue. Because of worse visualization, a longer time may have been spent to dissect in the correct plane. IPSS, QoL, PVR and PSA were similar in both groups at 1, 6, 12 and 18 months of follow up. No transfusions were required in either group, and no short or long term re-operations were mentioned [Zhang et al. 2012]. Learning curve. Although the outcomes of the Zhang series [Zhang et al. 2012] seem to be similar between the two laser technologies, HoLEP has been shown to demand a great learning curve, with cases required to become proficient [Brunckhorst et al. 2015]. Gross and colleagues addressed the learning curve of ThuVEP [Gross et al. 2012] All the 1080 cases were divided into consecutive groups of 216 patients each and complication rates were analyzed in each subgroup. Overall, complication rates decreased significantly over time, with a 41.7% complication rate within the first 216 cases and 19.4% within the last 216 cases (p < 0.001). ThuVEP may have an easier learning curve than HoLEP because the thulium laser allows for instant conversion to vaporization with the same end-fire fiber, a technique that more urologists are comfortable with. Cost. Currently no comparative cost studies have been performed specifically investigating thulium lasers. However, in 2001, a prospective, randomized trial investigating the cost effectiveness of holmium lasers traditional found catheterization time, length of hospital stay, risk of bleeding and incidence of untoward events reduced while offering equivalent outcomes at 1 year postoperatively. In a cost effectiveness analysis, these improvements represented a 24.5% cost saving over [Fraundorfer et al. 2001]. With regard to the thulium laser, acquisition costs are comparable with other laser modalities and the laser fibers cost about 450 each. In contrast to some other laser systems, however, the bare-ended quartz fibers of the thulium laser can be reused 189

10 Therapeutic Advances in Urology 8(3) many times, which leads to almost negligible running costs [Szlauer et al. 2009]. Conclusion With reports from around the world, the thulium laser prostatectomy represents a safe and efficacious procedure for benign prostatic obstruction. Multiple techniques including laser resection, vapoenucleation and vaporization have been described and appear to safe and effective with low morbidity. Overall, comparative studies with the traditional,, and HoLEP have demonstrated promising, noninferior data in terms of safety and efficacy. Thulium seems to provide better hemostasis, less overall morbidity, shorter catheterization time and a shorter hospital stay compared with the traditional. Also, its option for efficient vaporization in addition to enucleation makes it an easier technology for the average urologist to learn to use than the holmium laser. Finally, due to the physical properties of the laser, thulium laser prostatectomy may theoretically be associated with lower rates of dysuria compared with PVP, although studies are lacking. Further comparative studies are needed to explore this promising and user-friendly technology. Funding This research received no specific grant from any funding agency in the public, commercial, or notfor-profit sectors. Conflict of interest statement The authors declare no conflicts of interest in preparing this article. References Bach, T., Hermann, T., Ganzer, R., Burchardt, M. and Gross, A. (2007) Revolix vaporesection of the prostate: initial results of 54 patients with 1-year follow-up. World J Urol 25: Bach, T., Hermann, T., Hacker, A., Michel, M. and Gross, A. (2009a) Thulium:yttrium-aluminum-garnet laser prostatectomy in men with refractory urinary retention. BJU Int 104: Bach, T., Wendt-Nordahl, G., Michel, M., Hermann, T. and Gross, A. (2009b) Feasibility and efficacy of thulium:yag laser enucleation (vapoenucleation) of the prostate. World J Urol 27: Brunckhorst, O., Ahmed, K., Nehikhare, O., Marra, G., Challacombe, B. and Popert, R. (2015) Evaluation of the learning curve for holmium laser enucleation of the prostate using multiple outcome measures. Urology 86: Carmignani, L., Bozzini, G., Macchi, A., Maruccia, S., Picozzi, S. and Casellato, S. (2015) Sexual outcome of patients undergoing thulium laser enucleation of the prostate for benign prostatic hyperplasia. Asian J Androl 17: Chang, C., Lin, T., Chang, Y., Huang, W., Lin, A. and Chen, K. (2015) Vapoenucleation of the prostate using a high-power thulium laser: a one-year follow-up study. BMC Urol 15: 40. Cui, D., Sun, F., Zhuo, J., Sun, X., Han, B., Zhao, F. et al. (2014) A randomized trial comparing thulium laser resection to standard transurethral resection of the prostate for symptomatic benign prostatic hyperplasia: four-year follow-up results. World J Urol 32: Fraundorfer, M., Gilling, P., Kennett, K. and Dunton, N. (2001) Holmium laser resection of the prostate is more cost effective than transurethral resection of the prostate: results of a randomized prospective study. Urology 57: Fried, N. and Murray, K. (2005) High-power thulium fiber laser ablation of urinary tissues at 1.94 microm. J Endourol 19: Fu, W., Zhang, X., Yang, Y., Hong, B., Gao, J., Cai, W. et al. (2010) Comparison of 2-microm continuous wave laser vaporesection of the prostate and transurethral resection of the prostate: a prospective nonrandomized trial with 1-year follow-up. Urology 75: Gross, A., Netsch, C., Knipper, S., Holzel, J. and Bach, T. (2012) Complications and early postoperative outcome in 1080 patients after thulium vapoenucleation of the prostate: results at a single institution. Eur Urol 63: Hardy, L., Wilson, C., Irby, P. and Fried, N. (2014) Thulium fiber laser lithotripsy in an in vitro ureter model. J Biomed Opt 19: Iacono, F., Prezioso, D., Di Lauro, G., Romeo, G., Ruffo, A., Iliano, E. et al. (2012) Efficacy and safety profile of a novel technique, ThuLEP (Thulium laser enucleation of the prostate) for the treatment of benign prostate hypertrophy. Our experience on 148 patients. BMC Surg 12(Suppl 1): S21. Kyriazis, I., Swiniarski, P., Jutzi, S., Wolters, M., Netsch, C., Burchardt, M. et al. (2012) Transurethral anatomical enucleation of the prostate with Tm:YAG support (ThuLEP): review of the literature on a novel surgical approach in the management of benign prostatic enlargement. World J Urol 33:

11 Y Barbalat, MC Velez et al. Macchione, L., Mucciardi, G., Gali, A., Di Benedetto, A., Buttice, S. and Magno, C. (2013) Efficacy and safety of prostate vaporesection using a 120-W 2-µm continuous-wave Tm:YAG (RevoLix 2) in patients on continuous oral anticoagulant or antiplatelet therapy. Int Urol Nephrol 45: Mebust, W., Holtgrewe, H., Cockett, A. and Peters, P. (1989) Transurethral prostatectomy: immediate and postoperative complications. A cooperative study of 13 participating institutions evaluating 3,885 patients. J Urol 141: Netsch, C., Bach, T., Herrmann, T., Neubauer, O. and Gross, A. (2013) Evaluation of the learning curve for Thulium VapoEnucleation of the prostate (ThuVEP) using a mentor-based approach. World J Urol 31: Pariser, J., Famakinwa, O., Pearce, S. and Chung, D. (2014) High-power thulium laser vaporization of the prostate: short-term outcomes of safety and effectiveness. J Endourol 28: Parsons, J., Bergstrom, J., Silberstein, J. and Barrett- Connor, E. (2008) Prevalence and characteristics of lower urinary tract symptoms in men aged > or = 80 years. Urology 72: Peng, B., Wang, G., Zheng, J., Xia, S., Geng, J., Che, J. et al. (2013) A comparative study of thulium laser resection of the prostate and bipolar transurethral plasmakinetic prostatectomy for treating benign prostatic hyperplasia. BJU Int 111: Pereira-Correia, J., De Moraes Sousa, K., Santos, J., De Morais Perpetuo, D., Lopes-Da-Silva, L., Krambeck, R. et al. (2012) Greenlight HPS 120-W laser vaporization transurethral resection of the prostate (<60 Ml): a 2-year randomized double-blind prospective urodynamic investigation. BJU Int 110: Rassweiler, J., Teber, D., Kuntz, R. and Hofmann, R. (2006) Complications of transurethral resection of the prostate () incidence, management, and prevention. Eur Urol 50: ; discussion 980. Rausch, S., Heider, T., Bedke, J., Kruck, S., Schwentner, C., Fischer, K. et al. (2015) Analysis of early morbidity and functional outcome of thulium: yttrium-aluminum-garnet laser enucleation for benign prostate enlargement: patient age and prostate size determine adverse surgical outcome. Urology 85: Reich, O., Gratzke, C., Bachmann, A., Seitz, M., Schlenker, B., Hermanek, P. et al. (2008) Morbidity, mortality and early outcome of transurethral resection of the prostate: a prospective multicenter evaluation of 10,654 patients. J Urol 180: Rieken, M., Ebinger Mundorff, N., Bonkat, G., Wyler, S. and Bachmann, A. (2010) Complications of laser prostatectomy: a review of recent data. World J Urol 28: Sun, F., Han, B., Cui, D., Zhao, F., Sun, X., Zhuo, J. et al. (2015) Long-term results of thulium laser resection of the prostate: a prospective study at multiple centers. World J Urol 33: Szlauer, R., Gotschi, R., Razmaria, A., Paras, L. and Schmeller, N. (2009) Endoscopic vaporesection of the prostate using the continuous-wave 2-microm thulium laser: outcome and demonstration of the surgical technique. Eur Urol 55: Tang, K., Xu, Z., Xia, D., Ma, X., Guo, X., Guan, W. et al. (2014) Early outcomes of thulium laser transurethral resection of the prostate for managing benign prostatic hyperplasia: a systematic review and meta-analysis of comparative studies. J Endourol 28: Vargas, C., Garcia-Larrosa, A., Capdevila, S. and Laborda, A. (2014) Vaporization of the prostate with 150-W thulium laser: complications with 6-month follow-up. J Endourol 28: Wei, H., Shao, Y., Sun, F., Sun, X., Zhuo, J., Zhao, F. et al. (2014) Thulium laser resection plasmakinetic resection of prostates larger than 80 Ml. World J Urol 32: Wei, J., Calhoun, E. and Jacobsen, S. (2005) Urologic diseases in America project: benign prostatic hyperplasia. J Urol 173: Xia, S. (2009) Two-micron (thulium) laser resection of the prostate-tangerine technique: a new method for BPH treatment. Asian J Androl 11: Xia, S., Zhang, Y., Lu, J., Sun, X., Zhang, J., Zhu, Y. et al. (2005) [Thulium laser resection of prostatetangerine technique in treatment of benign prostate hyperplasia]. Zhonghua Yi Xue Za Zhi 85: Xia, S., Zhuo, J., Sun, X., Han, B., Shao, Y. and Zhang, Y. (2008) Thulium laser standard transurethral resection of the prostate: a randomized prospective trial. Eur Urol 53: Yang, Z., Wang, X. and Liu, T. (2013) Thulium laser enucleation plasmakinetic resection of the prostate: a randomized prospective trial with 18-month follow-up. Urology 81: Yu, X., Elliott, S., Wilt, T. and Mcbean, A. (2008) Practice patterns in benign prostatic hyperplasia surgical therapy: the dramatic increase in minimally invasive technologies. J Urol 180: ; discussion 245. Zhang, F., Shao, Q., Hermann, T., Tian, Y. and Zhang, Y. (2012) Thulium laser holmium laser transurethral enucleation of the prostate: 18-month follow-up data of a single center. Urology 79: Visit SAGE journals online SAGE journals 191

Combination of Thulium Laser Incision and Bipolar Resection Offers Higher Resection. Velocity than Bipolar Resection Alone in Large Prostates

Combination of Thulium Laser Incision and Bipolar Resection Offers Higher Resection. Velocity than Bipolar Resection Alone in Large Prostates Running Head: combination of thulium laser and bipolar in endoscopic prostatectomy-huang et al. Combination of Thulium Laser Incision and Bipolar Resection Offers Higher Resection Velocity than Bipolar

More information

Transurethral Laser Technology: Treatments for BPH

Transurethral Laser Technology: Treatments for BPH Transurethral Laser Technology: Treatments for BPH Richard Lee, MD Departments of Urology and Public Health The New York Presbyterian Hospital Weill Medical College of Cornell University Background Traditional

More information

Outcomes following Thulium vapoenucleation of large prostates

Outcomes following Thulium vapoenucleation of large prostates ORIGINAL ARTICLE Vol. 42 (4): 757-765, July - August, 2016 doi: 10.1590/S1677-5538.IBJU.2015.0424 Outcomes following Thulium vapoenucleation of large prostates Shane M. Pearce 1, Joseph J. Pariser 1, Rena

More information

Complications and Early Postoperative Outcome in 1080 Patients After Thulium Vapoenucleation of the Prostate: Results at a Single Institution

Complications and Early Postoperative Outcome in 1080 Patients After Thulium Vapoenucleation of the Prostate: Results at a Single Institution EUROPEAN UROLOGY 63 (2013) 859 867 available at www.sciencedirect.com journal homepage: www.europeanurology.com Platinum Priority Benign Prostatic Obstruction Editorial by Peter J. Gilling on pp. 868 869

More information

Thulium Laser versus Standard Transurethral Resection of the Prostate: A Randomized Prospective Trial

Thulium Laser versus Standard Transurethral Resection of the Prostate: A Randomized Prospective Trial european urology 53 (2008) 382 390 available at www.sciencedirect.com journal homepage: www.europeanurology.com Benign Prostatic Obstruction Thulium Laser versus Standard Transurethral Resection of the

More information

Submitted: August 15, Accepted: September 10, Published: October 15, 2018.

Submitted: August 15, Accepted: September 10, Published: October 15, 2018. Original Article doi: 10.22374/jeleu.v1i2.21 THULIUM LASER ENUCLEATION OF THE PROSTATE (THULEP) AS A TECHNIQUE FOR TREATMENT OF BPH: EVALUATION OF A SIX-YEAR EXPERIENCE AT A SINGLE INSTITUTION Mahmood

More information

Safety and efficacy of photoselective vaporization of the prostate using the 180-W GreenLight XPS laser system in patients taking oral anticoagulants

Safety and efficacy of photoselective vaporization of the prostate using the 180-W GreenLight XPS laser system in patients taking oral anticoagulants Clinical Report Safety and efficacy of photoselective vaporization of the prostate using the 180-W GreenLight XPS laser system in patients taking oral anticoagulants Journal of International Medical Research

More information

Vaporization of the Prostate with 150-W Thulium Laser: Complications with 6-Month Follow-Up

Vaporization of the Prostate with 150-W Thulium Laser: Complications with 6-Month Follow-Up JOURNAL OF ENDOUROLOGY Volume XX, Number XX, XXXX 2014 ª Mary Ann Liebert, Inc. Pp. --- --- DOI: 10.1089/end.2013.0715 Technology Vaporization of the Prostate with 150-W Thulium Laser: Complications with

More information

Original Article - Lasers in Urology. Min Ho Lee, Hee Jo Yang, Doo Sang Kim, Chang Ho Lee, Youn Soo Jeon

Original Article - Lasers in Urology. Min Ho Lee, Hee Jo Yang, Doo Sang Kim, Chang Ho Lee, Youn Soo Jeon www.kjurology.org http://dx.doi.org/10.4111/kju.2014.55.11.737 Original Article - Lasers in Urology http://crossmark.crossref.org/dialog/?doi=10.4111/kju.2014.55.11.737&domain=pdf&date_stamp=2014-11-16

More information

Treating BPH: Comparing Rezum UroLift and HoLEP

Treating BPH: Comparing Rezum UroLift and HoLEP Treating BPH: Comparing Rezum UroLift and HoLEP Scott M. Cheney MD Mayo Clinic Arizona 2018 MFMER slide-1 Welcome to AZ 2018 MFMER slide-2 Outline Background on BPH, Rezum, Urolift, HoLEP AUA Guideline

More information

Safety and effectiveness of high-power thulium laser enucleation of the prostate in patients with glands larger than 80 ml

Safety and effectiveness of high-power thulium laser enucleation of the prostate in patients with glands larger than 80 ml Chang et al. BMC Urology (2019) 19:8 https://doi.org/10.1186/s12894-019-0437-9 RESEARCH ARTICLE Open Access Safety and effectiveness of high-power thulium laser enucleation of the prostate in patients

More information

Early outcome of transurethral enucleation and resection of the prostate versus transurethral resection of the prostate

Early outcome of transurethral enucleation and resection of the prostate versus transurethral resection of the prostate Singapore Med J 2016; 57(12): 676-680 doi: 10.11622/smedj.2016026 Early outcome of transurethral enucleation and resection of the prostate versus transurethral resection of the prostate Sundaram Palaniappan

More information

Long-term Follow-up of Transurethral Enucleation Resection of the Prostate for Symptomatic Benign Prostatic Hyperplasia

Long-term Follow-up of Transurethral Enucleation Resection of the Prostate for Symptomatic Benign Prostatic Hyperplasia Journal of Surgery 2016; 4(2): 40-44 http://www.sciencepublishinggroup.com/j/js doi: 10.11648/j.js.20160402.18 ISSN: 2330-0914 (Print); ISSN: 2330-0930 (Online) Long-term Follow-up of Transurethral Enucleation

More information

Overview. Urology Dine and Learn: Erectile Dysfunction & Benign Prostatic Hyperplasia. Iain McAuley September 15, 2014

Overview. Urology Dine and Learn: Erectile Dysfunction & Benign Prostatic Hyperplasia. Iain McAuley September 15, 2014 Urology Dine and Learn: Erectile Dysfunction & Benign Prostatic Hyperplasia Iain McAuley September 15, 2014 Overview Review of the most recent guidelines for ED and BPH ED Guidelines CUA 2006 AUA 2011

More information

Early-Stage Clinical Experiences of Holmium Laser Enucleation of the Prostate (HoLEP)

Early-Stage Clinical Experiences of Holmium Laser Enucleation of the Prostate (HoLEP) JRural Med 2007 ; 2 : 93 97 Original article Early-Stage Clinical Experiences of Holmium Laser Enucleation of the Prostate (HoLEP) Shuzo Hamamoto 1,TakehikoOkamura 1,HideyukiKamisawa 1,KentaroMizuno 1,

More information

Index. urologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

Index. urologic.theclinics.com. Note: Page numbers of article titles are in boldface type. Index Note: Page numbers of article titles are in boldface type. A Ablative therapies, transurethral needle ablation, Adverse events, sexual side effects of BPH Aging, and incidence of BPH associated with

More information

Initial Experience of High Power Diode Laser for Vaporization of Prostate Muhammad Rafiq Zaki, Mujahid Hussain, Tahir Mehmood, Murtaza Hiraj

Initial Experience of High Power Diode Laser for Vaporization of Prostate Muhammad Rafiq Zaki, Mujahid Hussain, Tahir Mehmood, Murtaza Hiraj Original Article Initial Experience of High Power Diode Laser for Vaporization of Prostate Muhammad Rafiq Zaki, Mujahid Hussain, Tahir Mehmood, Murtaza Hiraj Abstract Objectives: Prospective evaluation

More information

REVIEWS. Laser treatment of benign prostate enlargement which laser for which prostate? Malte Rieken and Alexander Bachmann

REVIEWS. Laser treatment of benign prostate enlargement which laser for which prostate? Malte Rieken and Alexander Bachmann Laser treatment of benign prostate enlargement which laser for which prostate? Malte Rieken and Alexander Bachmann Abstract Laser-based prostatectomy for benign prostatic obstruction has emerged over the

More information

ISPUB.COM. Photoselective Vaporisation of the Prostate - Independent Surgical Experience Following Comprehensive Resident Training in the Technique.

ISPUB.COM. Photoselective Vaporisation of the Prostate - Independent Surgical Experience Following Comprehensive Resident Training in the Technique. ISPUB.COM The Internet Journal of Urology Volume 9 Number 4 Photoselective Vaporisation of the Prostate - Independent Surgical Experience Following Comprehensive Resident Training in the Technique. R Eapen,

More information

Wednesday 25 June Poster Session 9: BPH 1 Chairmen: M. Speakman and D. Rosario

Wednesday 25 June Poster Session 9: BPH 1 Chairmen: M. Speakman and D. Rosario Wednesday 25 June 14.30 15.30 Poster Session 9: BPH 1 Chairmen: M. Speakman and D. Rosario P080 Unreliable residual volume measurement after increased water load diuresis G. ALIVIZATOS, A. SKOLARIKOS,

More information

Comparison of outpatient versus inpatient transurethral prostate resection for benign prostatic hyperplasia: Comparative, prospective bi-centre study

Comparison of outpatient versus inpatient transurethral prostate resection for benign prostatic hyperplasia: Comparative, prospective bi-centre study original research Comparison of outpatient versus inpatient transurethral prostate resection for benign prostatic hyperplasia: Comparative, prospective bi-centre study Jae Heon Kim, MD; * Jae Young Park,

More information

HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION.

HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION. IN YOUR HANDS HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION. Main Application Fields UROLOGY GENERAL SURGERY ENT LASER AT YOUR SIDE IN YOUR HANDS is a high power holmium laser

More information

Outcome of 980 nm diode laser vaporization for benign prostatic hyperplasia: A prospective study

Outcome of 980 nm diode laser vaporization for benign prostatic hyperplasia: A prospective study Original Article - Lower Urinary Tract Dysfunction pissn 2466-0493 eissn 2466-054X Outcome of 980 nm diode laser vaporization for benign prostatic hyperplasia: A prospective study M. Hammad Mithani, Salman

More information

Biomedical Research 2017; 28 (12):

Biomedical Research 2017; 28 (12): Biomedical Research 2017; 28 (12): 5432-5437 ISSN 0970-938X www.biomedres.info A prospective, randomised trial comparing transurethral enucleation with bipolar system (TUEB) to monopolar resectoscope enucleation

More information

Randomized, controlled trial of laser vs. bipolar plasma vaporization treatment of benign prostatic hyperplasia

Randomized, controlled trial of laser vs. bipolar plasma vaporization treatment of benign prostatic hyperplasia ORIGINAL RESEARCH Randomized, controlled trial of laser vs. bipolar plasma vaporization treatment of benign prostatic hyperplasia Thomas A.A. Skinner, MSc, MD; Robert J. Leslie, MSc, MD; Stephen S. Steele,

More information

Xin Li 1, Jin-hong Pan 1, Qi-gui Liu 2, Peng He 1, Si-ji Song 1, Tao Jiang 1, Zhan-song Zhou 1 * Abstract. Introduction

Xin Li 1, Jin-hong Pan 1, Qi-gui Liu 2, Peng He 1, Si-ji Song 1, Tao Jiang 1, Zhan-song Zhou 1 * Abstract. Introduction Combined with Transurethral Incision of the Bladder Neck for Bladder Outlet Obstruction in Patients with Small Volume Benign Prostate Hyperplasia (BPH): A Prospective Randomized Study Xin Li 1, Jin-hong

More information

Holmium:YAG Transurethral Incision Versus Laser Photoselective Vaporization for Benign Prostatic Hyperplasia in a Small Prostate

Holmium:YAG Transurethral Incision Versus Laser Photoselective Vaporization for Benign Prostatic Hyperplasia in a Small Prostate Holmium:YAG Transurethral Incision Versus Laser Photoselective Vaporization for Benign Prostatic Hyperplasia in a Small Prostate Ahmed M. Elshal, Mohamed A. Elkoushy, Hazem M. Elmansy, John Sampalis and

More information

HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION. Main Application Fields UROLOGY GENERAL SURGERY ENT

HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION. Main Application Fields UROLOGY GENERAL SURGERY ENT IN YOUR HANDS HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION. Main Application Fields UROLOGY GENERAL SURGERY ENT Manufactured by Asclepion Laser Technologies GmbH LASER AT

More information

Benign enlargement of prostate (BEP), which is. Early Experiences with HoLEP. Original Article ABSTRACT INTRODUCTION. Bhandari BB*

Benign enlargement of prostate (BEP), which is. Early Experiences with HoLEP. Original Article ABSTRACT INTRODUCTION. Bhandari BB* Original Article Early Experiences with HoLEP Bhandari BB* * Consultant Urologist, Shree Birendra Army Hospital, Norvic International Hospital, Alka Hospital ABSTRACT introduction: Holmium Laser Enucleation

More information

Benign prostatic hyperplasia (BPH) is one of the

Benign prostatic hyperplasia (BPH) is one of the MISCELLANEOUS Safety and Efficacy of Bipolar Versus Monopolar Transurethral Resection of the Prostate: A Comparative Study Erkan Hirik, 1 Aliseydi Bozkurt, 1 Mehmet Karabakan, 1 * Huseyin Aydemir, 2 Binhan

More information

EUROPEAN UROLOGY 58 (2010)

EUROPEAN UROLOGY 58 (2010) EUROPEAN UROLOGY 58 (2010) 349 355 available at www.sciencedirect.com journal homepage: www.europeanurology.com Platinum Priority Benign Prostatic Hyperplasia Editorial by Petrisor Geavlete on pp. 356

More information

1 Department of Urology, the First Affiliated Hospital of Fujian Medical University, Fuzhou, China

1 Department of Urology, the First Affiliated Hospital of Fujian Medical University, Fuzhou, China ORIGINAL ARTICLE Vol. 42 (4): 747-756, July - August, 2016 doi: 10.1590/S1677-5538.IBJU.2015.0225 Bipolar transurethral enucleation and resection of the prostate versus bipolar resection of the prostate

More information

EFFICACY OF LASER SURGERY FOR BENIGN PROSTATIC HYPERPLASIA TREATMENT

EFFICACY OF LASER SURGERY FOR BENIGN PROSTATIC HYPERPLASIA TREATMENT EFFICACY OF LASER SURGERY FOR BENIGN PROSTATIC HYPERPLASIA TREATMENT Hasmeinda Medical faculty of Universitas Muhammadiyah Surakarta ABSTRACT Benign prostatic hyperplasia (BPH) is the most important cases

More information

Impact of endoscopic enucleation of the prostate with thulium fiber laser on the erectile function

Impact of endoscopic enucleation of the prostate with thulium fiber laser on the erectile function Enikeev et al. BMC Urology (2018) 18:87 https://doi.org/10.1186/s12894-018-0400-1 RESEARCH ARTICLE Impact of endoscopic enucleation of the prostate with thulium fiber laser on the erectile function Dmitry

More information

Int J Clin Exp Med 2016;9(4): /ISSN: /IJCEM

Int J Clin Exp Med 2016;9(4): /ISSN: /IJCEM Int J Clin Exp Med 2016;9(4):7328-7333 www.ijcem.com /ISSN:1940-5901/IJCEM0021226 Original Article Comparison of plasmakinetic enucleation of the prostate with holmium laser enucleation of the prostate

More information

GUIDELINES ON NON-NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION

GUIDELINES ON NON-NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION GUIDELINES ON NON-NEUROGENIC MLE LUTS INCLUDING BENIGN PROSTTIC OBSTRUCTION (Text update March 2015) S. Gravas (Chair), T. Bach,. Bachmann, M. Drake, M. Gacci, C. Gratzke, S. Madersbacher, C. Mamoulakis,

More information

Lasers in Urology. Ju Hyun Park 1, Hwancheol Son 1,2, Jae-Seung Paick 1. DOI: /kju

Lasers in Urology. Ju Hyun Park 1, Hwancheol Son 1,2, Jae-Seung Paick 1.   DOI: /kju www.kjurology.org DOI:10.4111/kju.2010.51.2.115 Lasers in Urology Comparative Analysis of the Efficacy and Safety of Photoselective Vaporization of the Prostate for Treatment of Benign Prostatic Hyperplasia

More information

Se-Hee Kang, Yong Sun Choi, Su Jin Kim, Hyuk Jin Cho, Sung-Hoo Hong, Ji Youl Lee, Tae-Kon Hwang, Sae Woong Kim

Se-Hee Kang, Yong Sun Choi, Su Jin Kim, Hyuk Jin Cho, Sung-Hoo Hong, Ji Youl Lee, Tae-Kon Hwang, Sae Woong Kim www.kjurology.org DOI:10.4111/kju.2011.52.4.260 Lasers in Urology Long-Term Follow-Up Results of Photoselective Vaporization of the Prostate with the 120 W Greenlight HPS Laser for Treatment of Benign

More information

Roberto Giulianelli, Barbara Gentile, Luca Albanesi, Paola Tariciotti, and Gabriella Mirabile

Roberto Giulianelli, Barbara Gentile, Luca Albanesi, Paola Tariciotti, and Gabriella Mirabile Surgical Techniques in Urology Bipolar Button Transurethral Enucleation of Prostate in Benign Prostate Hypertrophy Treatment: A New Surgical Technique Roberto Giulianelli, Barbara Gentile, Luca Albanesi,

More information

BENIGN PROSTATIC HYPERPLASIA (BPH) affects 70%

BENIGN PROSTATIC HYPERPLASIA (BPH) affects 70% JOURNAL OF ENDOUROLOGY Volume 14, Number 2, March 2000 Mary Ann Liebert, Inc. Holmium Laser Enucleation of the Prostate With Tissue Morcellation: Initial United States Experience JEFFREY A. MOODY, M.D.,

More information

980-nm Diode Laser: A Novel Laser Technology for Vaporization of the Prostate

980-nm Diode Laser: A Novel Laser Technology for Vaporization of the Prostate european urology 52 (2007) 1723 1728 available at www.sciencedirect.com journal homepage: www.europeanurology.com Benign Prostatic Obstruction 980-nm Diode Laser: A Novel Laser Technology for Vaporization

More information

Can men with prostates sized 80 ml or larger be managed conservatively?

Can men with prostates sized 80 ml or larger be managed conservatively? Original Article - Lower Urinary Tract Dysfunction Investig Clin Urol 2017;58:359-364. pissn 2466-0493 eissn 2466-054X Can men with prostates sized 80 ml or larger be managed conservatively? Alvin Lee,

More information

GUIDELINES ON NON-NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION (BPO)

GUIDELINES ON NON-NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION (BPO) GUIDELINES ON NON-NEUROGENIC MLE LUTS INCLUDING BENIGN PROSTTIC OBSTRUCTION (BPO) (Text update pril 2014) S. Gravas (chair),. Bachmann,. Descazeaud, M. Drake, C. Gratzke, S. Madersbacher, C. Mamoulakis,

More information

Cheng Liu, Xuejun Liu, Duo Liu, Jiagui Mu, Dongsheng Zhu, Li Fan, Qun Song, Dongwei Yao *

Cheng Liu, Xuejun Liu, Duo Liu, Jiagui Mu, Dongsheng Zhu, Li Fan, Qun Song, Dongwei Yao * Biomedical Research 2017; 28 (5): 2278-2283 ISSN 0970-938X www.biomedres.info Effect of dual-band semiconductor laser transurethral resection of prostate on efficacy, stress response and quality of life

More information

PHOTOSELECTIVE POTASSIUM-TITANYL-PHOSPHATE LASER VAPORIZATION OF THE BENIGN OBSTRUCTIVE PROSTATE: OBSERVATIONS ON LONG-TERM OUTCOMES

PHOTOSELECTIVE POTASSIUM-TITANYL-PHOSPHATE LASER VAPORIZATION OF THE BENIGN OBSTRUCTIVE PROSTATE: OBSERVATIONS ON LONG-TERM OUTCOMES 0022-5347/05/1744-1344/0 Vol. 174, 1344 1348, October 2005 THE JOURNAL OF UROLOGY Printed in U.S.A. Copyright 2005 by AMERICAN UROLOGICAL ASSOCIATION DOI: 10.1097/01.ju.0000173913.41401.67 PHOTOSELECTIVE

More information

INJINTERNATIONAL. Original Article INTRODUCTION. Int Neurourol J 2017;21: pissn eissn

INJINTERNATIONAL. Original Article INTRODUCTION. Int Neurourol J 2017;21: pissn eissn Official Journal of Korean Continence Society / Korean Society of Urological Research / The Korean Children s Continence and Enuresis Society / The Korean Association of Urogenital Tract Infection and

More information

Review Article A Personal Reflection of Greenlight 532 nm Laser for BPH Treatment

Review Article A Personal Reflection of Greenlight 532 nm Laser for BPH Treatment Advances in Andrology, Article ID 207901, 6 pages http://dx.doi.org/10.1155/2014/207901 Review Article A Personal Reflection of Greenlight 532 nm Laser for BPH Treatment Bilal Chughtai, Claire Dunphy,

More information

Runnig Head: Prevention of irritative syndrome after PVP-Way et al.

Runnig Head: Prevention of irritative syndrome after PVP-Way et al. Runnig Head: Prevention of irritative syndrome after PVP-Way et al. The Effect of Anticholinergics for Prevention of Storage Symptoms After Prostate Photovaporization David Alejandro Martín Way*, Rocio

More information

Original Policy Date

Original Policy Date MP 7.01.39 Transurethral Microwave Thermotherapy Medical Policy Section Surgery Issue 12:2013 Original Policy Date 12:2013 Last Review Status/Date Reviewed with literature search/12:2013 Return to Medical

More information

Outcomes of the Holmium Laser Enucleation of the Prostate for Patients With Prior Benign Prostatic Hyperplasia Surgery

Outcomes of the Holmium Laser Enucleation of the Prostate for Patients With Prior Benign Prostatic Hyperplasia Surgery Original Article J Korean Geriatr Soc 2014;18(4):199-204 http://dx.doi.org/10.4235/jkgs.2014.18.4.199 Print ISSN 1229-2397 On-line ISSN 2288-1239 Outcomes of the Holmium Laser Enucleation of the Prostate

More information

Lasers in Urology. Sae Woong Choi, Yong Sun Choi, Woong Jin Bae, Su Jin Kim, Hyuk Jin Cho, Sung Hoo Hong, Ji Youl Lee, Tae Kon Hwang, Sae Woong Kim

Lasers in Urology. Sae Woong Choi, Yong Sun Choi, Woong Jin Bae, Su Jin Kim, Hyuk Jin Cho, Sung Hoo Hong, Ji Youl Lee, Tae Kon Hwang, Sae Woong Kim www.kjurology.org http://dx.doi.org/10.4111/kju.2011.52.12.824 Lasers in Urology 120 W Greenlight HPS Laser Photoselective Vaporization of the Prostate for Treatment of Benign Prostatic Hyperplasia in

More information

NOTE: This policy is not effective until April 1, Transurethral Water Vapor Thermal Therapy of the Prostate

NOTE: This policy is not effective until April 1, Transurethral Water Vapor Thermal Therapy of the Prostate NOTE: This policy is not effective until April 1, 2019. Medical Policy Manual Surgery, Policy No. 210 Transurethral Water Vapor Thermal Therapy of the Prostate Next Review: December 2019 Last Review: December

More information

TITLE: Plasma Vaporization of the Prostate for Treatment of Benign Prostatic Hypertrophy: A Review of Clinical and Cost-Effectiveness, and Safety

TITLE: Plasma Vaporization of the Prostate for Treatment of Benign Prostatic Hypertrophy: A Review of Clinical and Cost-Effectiveness, and Safety TITLE: Plasma Vaporization of the Prostate for Treatment of Benign Prostatic Hypertrophy: A Review of Clinical and Cost-Effectiveness, and Safety DATE: 05 March 2014 CONTEXT AND POLICY ISSUES Benign prostatic

More information

Technique and Short-Term Outcome of Green Light Laser (KTP, 80 W) Vaporisation of the Prostate

Technique and Short-Term Outcome of Green Light Laser (KTP, 80 W) Vaporisation of the Prostate european urology 52 (2007) 1632 1637 available at www.sciencedirect.com journal homepage: www.europeanurology.com Surgery in Motion Technique and Short-Term Outcome of Green Light Laser (KTP, 80 W) Vaporisation

More information

Yong Taec Lee, Young Woo Ryu, Dong Min Lee, Sang Wook Park, Seung Hee Yum, June Hyun Han

Yong Taec Lee, Young Woo Ryu, Dong Min Lee, Sang Wook Park, Seung Hee Yum, June Hyun Han www.kjurology.org http://dx.doi.org/10.4111/kju.2011.52.11.763 Voiding Dysfunction Comparative Analysis of the Efficacy and Safety of Conventional Transurethral Resection of the Prostate, Transurethral

More information

Diode Laser Treatment of Human Prostates

Diode Laser Treatment of Human Prostates Original Article Diode Laser Treatment of Human Prostates Mohammad Reza Razzaghi, Hooman Mokhtarpour, Mohammad Mohsen Mazloomfard Laser Application in Medical Sciences Research Center, Shahid Beheshti

More information

Rezūm procedure for the Prostate

Rezūm procedure for the Prostate Rezūm procedure for the Prostate Mr Jas Kalsi Consultant Urological Surgeon This booklet has been provided to help answer the questions you may have with regards to your enlarged prostate and the Rezūm

More information

Service Line: Rapid Response Service Version: 1.0 Publication Date: March 01, 2017 Report Length: 16 Pages

Service Line: Rapid Response Service Version: 1.0 Publication Date: March 01, 2017 Report Length: 16 Pages CADTH RAPID RESPONSE REPORT: SUMMARY WITH CRITICAL APPRAISAL Bipolar versus Monopolar Transurethral Resection of the Prostate or GreenLight Laser Treatment: A Review of Clinical and Cost-Effectiveness

More information

Original Article HoLEP: the gold standard for the surgical management of BPH in the 21 st Century

Original Article HoLEP: the gold standard for the surgical management of BPH in the 21 st Century Am J Clin Exp Urol 2015;3(1):36-42 www.ajceu.us /ISSN:2330-1910/AJCEU0007305 Original Article HoLEP: the gold standard for the surgical management of BPH in the 21 st Century John Michalak, David Tzou,

More information

IS IRRIGATION NECESSARY AFTER MONOPOLAR TURP? OUR 11 YEARS EXPERIENCE

IS IRRIGATION NECESSARY AFTER MONOPOLAR TURP? OUR 11 YEARS EXPERIENCE IS IRRIGATION NECESSARY AFTER MONOPOLAR TURP? OUR 11 YEARS EXPERIENCE Prasannakumar K, Venkatesh Krishnamoorthy, Maneesh Sinha, Krishna Prasad T, Pradeepa MG Abstract Objective: This study was conducted

More information

Transurethral incision versus transurethral resection of the prostate in small prostatic adenoma: Long-term follow-up

Transurethral incision versus transurethral resection of the prostate in small prostatic adenoma: Long-term follow-up African Journal of Urology (2012) 18, 29 33 Pan African Urological Surgeons Association African Journal of Urology www.ees.elsevier.com/afju www.sciencedirect.com Transurethral incision versus transurethral

More information

Prostatic Diseases and Male Voiding Dysfunction

Prostatic Diseases and Male Voiding Dysfunction Prostatic Diseases and Male Voiding Dysfunction Prostatic-specific Antigen Velocity After Holmium Laser Enucleation of the Prostate: Possible Predictor for the Assessment of Treatment Effect Durability

More information

Lasers in Urology. Hyeon Jun Kim, Han Yi Lee, Sang Hun Song 1, Jae-Seung Paick.

Lasers in Urology. Hyeon Jun Kim, Han Yi Lee, Sang Hun Song 1, Jae-Seung Paick. www.kjurology.org http://dx.doi.org/10.4111/kju.2013.54.2.89 Lasers in Urology Relationship of Postoperative Recatheterization and Intraoperative Bladder Distention Volume in Holmium Laser Enucleation

More information

Can 80 W KTP Laser Vaporization Effectively Relieve the Obstruction in Benign Prostatic Hyperplasia?: A Nonrandomized Trial

Can 80 W KTP Laser Vaporization Effectively Relieve the Obstruction in Benign Prostatic Hyperplasia?: A Nonrandomized Trial pissn: 2287-428 / eissn: 2287-469 World J Mens Health 212 December 3(3): 16-165 http://dx.doi.org/1.5534/wjmh.212.3.3.16 Original Article Can 8 W KTP Laser Vaporization Effectively Relieve the Obstruction

More information

Bimalesh Purkait, Rahul Janak Sinha, Krishna Swamy A. Srinivas, Ankur Bansal, Ashok Kumar Sokhal, Vishwajeet Singh

Bimalesh Purkait, Rahul Janak Sinha, Krishna Swamy A. Srinivas, Ankur Bansal, Ashok Kumar Sokhal, Vishwajeet Singh 176 Turk J Urol 2017; 43(2): 176-82 DOI: 10.5152/tud.2017.20586 GENERAL UROLOGY Original Article Outcome analysis of transurethral resection versus potassium titanyl phosphate-photo selective vaporization

More information

Author's Accepted Manuscript

Author's Accepted Manuscript Author's Accepted Manuscript Direct comparison of Green Light Laser XPS Photoselective Vaporization of the Prostate (PVP) and Green Laser En Bloc enucleation of the prostate (GreenLEP) in enlarged glands

More information

Benign Prostatic Hyperplasia (BPH) is a common

Benign Prostatic Hyperplasia (BPH) is a common Photomedicine and Laser Surgery Volume 35, Number 6, 2017 ª Mary Ann Liebert, Inc. Pp. 300 304 DOI: 10.1089/pho.2016.4237 Photoselective Vaporization of the Prostate Using 120 W High Performance System:

More information

EAU GUIDELINES ON NON- NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION

EAU GUIDELINES ON NON- NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION EAU GUIDELINES ON NON- NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION (Limited text update March 2016) S. Gravas (Chair), T. Bach, A. Bachmann, M. Drake, M. Gacci, C. Gratzke, S. Madersbacher,

More information

GREENLIGHT XPS LASER THERAPY SYSTEM: A SYSTEMATIC APPROACH TO VAPORIZATION

GREENLIGHT XPS LASER THERAPY SYSTEM: A SYSTEMATIC APPROACH TO VAPORIZATION TM GREENLIGHT XPS LASER THERAPY SYSTEM: A SYSTEMATIC APPROACH TO VAPORIZATION Gregg R. Eure, MD, FACS Urology of Virginia Virginia Beach, Virginia GREENLIGHT XPS TM A SYSTEMATIC APPROACH TO VAPORIZATION

More information

Original Article Comparative study of 2 um laser versus Holmium laser for the resection of non-muscle invasive bladder cancer

Original Article Comparative study of 2 um laser versus Holmium laser for the resection of non-muscle invasive bladder cancer Int J Clin Exp Med 2016;9(12):23618-23623 www.ijcem.com /ISSN:1940-5901/IJCEM0030284 Original Article Comparative study of 2 um laser versus Holmium laser for the resection of non-muscle invasive bladder

More information

Review of Current Laser Therapies for the Treatment of Benign Prostatic Hyperplasia

Review of Current Laser Therapies for the Treatment of Benign Prostatic Hyperplasia www.kjurology.org http://dx.doi.org/10.4111/kju.2013.54.6.351 Review Article Review of Current Laser Therapies for the Treatment of Benign Prostatic Hyperplasia E. Charles Osterberg, Benjamin B. Choi Department

More information

Efficacy and safety of photoselective vaporization of the prostate in patients with prostatic obstruction induced by advanced prostate cancer

Efficacy and safety of photoselective vaporization of the prostate in patients with prostatic obstruction induced by advanced prostate cancer Asian Journal of Surgery (2011) 34, 135e139 Available online at www.sciencedirect.com journal homepage: www.e-asjsur.com ORIGINAL ARTICLE Efficacy and safety of photoselective vaporization of the prostate

More information

european urology 54 (2008)

european urology 54 (2008) european urology 54 (2008) 427 437 available at www.sciencedirect.com journal homepage: www.europeanurology.com Benign Prostatic Obstruction Transurethral Photoselective Vaporization versus Transvesical

More information

Prostate Artery Embolization

Prostate Artery Embolization Prostate Artery Embolization in the office interventional suite Robert J. Kennedy, M.D. Interventional & Vascular Center Melbourne, Florida The speaker has no financial conflicts of interest to disclose.

More information

PROSTATIC EMBOLIZATION FOR BENIGN HYPERPLASIA

PROSTATIC EMBOLIZATION FOR BENIGN HYPERPLASIA St. Louis Hospital PROSTATIC EMBOLIZATION FOR BENIGN HYPERPLASIA INITIAL CLINICAL RESULTS Faculty of Medical Sciences New University of Lisbon JOÃO PISCO LUÍS CAMPOS PINHEIRO TIAGO BILHIM HUGO RIO TINTO

More information

Voiding Dysfunction. Joon Seok Kwon, Jung Woo Lee 1, Seung Wook Lee, Hong Yong Choi, Hong Sang Moon. DOI: /kju

Voiding Dysfunction. Joon Seok Kwon, Jung Woo Lee 1, Seung Wook Lee, Hong Yong Choi, Hong Sang Moon.  DOI: /kju www.kjurology.org DOI:10.4111/kju.2011.52.4.269 Voiding Dysfunction Comparison of Effectiveness of Monopolar and Bipolar Transurethral Resection of the Prostate and Open Prostatectomy in Large Benign Prostatic

More information

OUTCOMES OF HoLEP IN THE RETREATMENT SETTING

OUTCOMES OF HoLEP IN THE RETREATMENT SETTING OUTCOMES OF HoLEP IN THE RETREATMENT SETTING Tracy Marien 1 MD, Mustafa Kadihasanoglu 1 MD, Teerayut Tangpaitoon 1 MD, Nadya York 2 MD, Andrew T. Blackburne 3 MD, Haidar Abdul-Muhsin 4 MD, Michael S. Borofsky

More information

(2018) The Clinical Effect of Bipolar Transurethral Resection in Saline of Benign. Hyperplasia with Long Term Follow-Up

(2018) The Clinical Effect of Bipolar Transurethral Resection in Saline of Benign. Hyperplasia with Long Term Follow-Up Open Journal of Urology, 2018, 8, 108-117 http://www.scirp.org/journal/oju ISSN Online: 2160-5629 ISSN Print: 2160-5440 The Clinical Effect of Bipolar Transurethral Resection in Saline of Benign Prostate

More information

Holmium laser enucleation of the prostate: a review of the clinical trial evidence

Holmium laser enucleation of the prostate: a review of the clinical trial evidence 511509TAU0010.1177/1756287213511509Therapeutic Advances in UrologyM Cynk 2013511509 Therapeutic Advances in Urology Review Holmium laser enucleation of the prostate: a review of the clinical trial evidence

More information

JMSCR Vol 04 Issue 10 Page October 2016

JMSCR Vol 04 Issue 10 Page October 2016 www.jmscr.igmpublication.org Impact Factor 5.244 Index Copernicus Value: 83.27 ISSN (e)-2347-176x ISSN (p) 2455-0450 DOI: https://dx.doi.org/10.18535/jmscr/v4i10.40 Combined Bladder Stones Removal: In

More information

Photoselective vaporization of the prostate towards a new standard

Photoselective vaporization of the prostate towards a new standard (2007) 10, S10 S14 & 2007 Nature Publishing Group All rights reserved 1365-7852/07 $30.00 ORIGINAL ARTICLE www.nature.com/pcan towards a new standard Galway Clinic, Doughiska, Galway, Ireland Many technologies

More information

Best laser for prostatectomy in the year 2013

Best laser for prostatectomy in the year 2013 Symposium Best laser for prostatectomy in the year 2013 Pankaj N. Maheshwari 1, Nitin Joshi 2, Reeta P. Maheshwari 1 Departments of Urology, 1 Aditya Birla Memorial Hospital, Chinchwad, Pune, 2 Shree Ramkrishna

More information

ISSN: (Print) (Online) Journal homepage:

ISSN: (Print) (Online) Journal homepage: Archives of Andrology Journal of Reproductive Systems ISSN: 0148-5016 (Print) (Online) Journal homepage: http://www.tandfonline.com/loi/iaan19 CHANGE IN INTERNATIONAL PROSTATE SYMPTOM SCORE AFTER TRANSURETHRAL

More information

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE Medical technology guidance SCOPE The UroLift system for the treatment of lower urinary tract symptoms secondary to benign prostatic hyperplasia 1

More information

Holmium Laser Enucleation of the Prostate: Modified Morcellation Technique and Results

Holmium Laser Enucleation of the Prostate: Modified Morcellation Technique and Results www.kjurology.org http://dx.doi.org/10.4111/kju.2012.53.11.779 Voiding Dysfunction Holmium Laser Enucleation of the Prostate: Modified Morcellation Technique and Results Su Hyung Lee, Jong In Choi, Kyung

More information

Benign Prostatic Hyperplasia (BPH)

Benign Prostatic Hyperplasia (BPH) Benign Prostatic Hyperplasia (BPH) Definition Prostate gland enlargement is a common condition as men get older. Also called benign prostatic hyperplasia (BPH), prostate gland enlargement can cause bothersome

More information

Title:Transurethral Cystolitholapaxy with the AH -1 Stone Removal System for the Treatment of Bladder Stones of Variable Size

Title:Transurethral Cystolitholapaxy with the AH -1 Stone Removal System for the Treatment of Bladder Stones of Variable Size Author's response to reviews Title:Transurethral Cystolitholapaxy with the AH -1 Stone Removal System for the Treatment of Bladder Stones of Variable Size Authors: Aihua Li (Li121288@aliyun.com) Chengdong

More information

Lasers in Urology. An Evidence-Based Approach to Choosing the Right Tool

Lasers in Urology. An Evidence-Based Approach to Choosing the Right Tool Lasers in Urology An Evidence-Based Approach to Choosing the Right Tool Today medical lasers and specifically designed optical fibers offer benefits in a variety of surgical applications. Selecting the

More information

Impact of Changing Trends in Medical Therapy on Surgery for Benign Prostatic Hyperplasia Over Two Decades

Impact of Changing Trends in Medical Therapy on Surgery for Benign Prostatic Hyperplasia Over Two Decades www.kjurology.org http://dx.doi.org/10.4111/kju.2012.53.1.23 Voiding Dysfunction Impact of Changing Trends in Medical Therapy on Surgery for Benign Prostatic Hyperplasia Over Two Decades Se Young Choi,

More information

Original Article Retrospective comparison of the modified and traditional holmium laser transurethral prostatectomy based on a 1-year follow-up

Original Article Retrospective comparison of the modified and traditional holmium laser transurethral prostatectomy based on a 1-year follow-up Int J Clin Exp Med 2016;9(2):4009-4015 www.ijcem.com /ISSN:1940-5901/IJCEM0017779 Original Article Retrospective comparison of the modified and traditional holmium laser transurethral prostatectomy based

More information

Name of Policy: Transurethral Microwave Thermotherapy

Name of Policy: Transurethral Microwave Thermotherapy Name of Policy: Transurethral Microwave Thermotherapy Policy #: 449 Latest Review Date: September 2013 Category: Surgery Policy Grade: B Background/Definitions: As a general rule, benefits are payable

More information

Holmium laser enucleation of the prostate: surgical, functional, and quality-of-life outcomes upon extended follow-up

Holmium laser enucleation of the prostate: surgical, functional, and quality-of-life outcomes upon extended follow-up ORIGINAL ARTICLE Vol. 42 (2): 293-301, March - April, 2016 doi: 10.1590/S1677-5538.IBJU.2014.0561 Holmium laser enucleation of the prostate: surgical, functional, and quality-of-life outcomes upon extended

More information

Surgical Treatment of LUTS in Men with BPE

Surgical Treatment of LUTS in Men with BPE Patient Information English 35 Surgical Treatment of LUTS in Men with BPE The underlined terms are listed in the glossary. You have been diagnosed with benign prostatic enlargement (BPE) and your doctor

More information

The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode

The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode 282 Original Paper FUNCTIONAL UROLOGY The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode Mariusz Szewczyk 1,

More information

EAU GUIDELINES ON NON- NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION

EAU GUIDELINES ON NON- NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION EAU GUIDELINES ON NON- NEUROGENIC MALE LUTS INCLUDING BENIGN PROSTATIC OBSTRUCTION (Text update March 2017) S. Gravas (Chair), T. Bach, M. Drake, M. Gacci, C. Gratzke, T.R.W. Herrmann, S. Madersbacher,

More information

Bipolar Transurethral Resection of the Prostate: Perioperative Safety and Functional Outcome: Prospective Randomized Study

Bipolar Transurethral Resection of the Prostate: Perioperative Safety and Functional Outcome: Prospective Randomized Study World Journal of Medical Sciences 11 (4): 439-444, 014 ISSN 1817-3055 IDOSI Publications, 014 DOI: 10.589/idosi.wjms.014.11.4.866 Bipolar Transurethral Resection of the Prostate: Perioperative Safety and

More information

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE INTERVENTIONAL PROCEDURES PROGRAMME Interventional procedure overview of transurethral water jet ablation for lower urinary tract symptoms caused by benign

More information

MODULE 3: BENIGN PROSTATIC HYPERTROPHY

MODULE 3: BENIGN PROSTATIC HYPERTROPHY MODULE 3: BENIGN PROSTATIC HYPERTROPHY KEYWORDS: Prostatic hypertrophy, prostatic hyperplasia, PSA, voiding dysfunction, lower urinary tract symptoms (LUTS) At the end of this clerkship, the medical student

More information

Holmium laser enucleation of the prostate can be taught: the first learning experience

Holmium laser enucleation of the prostate can be taught: the first learning experience Blackwell Science, LtdOxford, UK BJUBJU International1464-4096BJU International 909December 2002 3071 LEARNING HoLEP A. EL-HAKIM and M.M. ELHILALI 10.1046/j.1464-4096.2002.03071.x Original Article863869BEES

More information