TC for Acoustics, Ultrasound and Vibration: Highlights Salvador Barrera-

Size: px
Start display at page:

Download "TC for Acoustics, Ultrasound and Vibration: Highlights Salvador Barrera-"

Transcription

1 TC for Acoustics, Ultrasound and Vibration: Highlights Salvador Barrera-Figueroa, TC-AUV Chair 1

2 Outline Overview of the TC-AUV Highlights: EMRP IND09 Traceable Dynamic Measurement of Mechanical Quantities EMRP HLT01 EARS: Metrology for a universal ear simulator and the perception of non-audible sound EMRP HLT03 DUTy: Dosimetry for ultrasound therapy New EMRP proposals 2

3 Overview of the TCAUV Sub-Committes: 3 Members: 25 Comparisons: 2 CCAUV, 2 EURAMET, 2 COOMET, 3 Bilateral Projects: 9 CMC entries: 511 3

4 Highlights: EMRP Project IND09 Traceable Dynamic Measurement of Mechanical Quantities 4

5 The Objective of EMRP-JRP-IND09 traceable dynamic measurement of mechanical quantities Establish traceability for the dynamic quantities Force (periodic and shock) Torque (periodic) Pressure (Shock, gaseous, liquid) Conditioning amplifier sensitivity (charge, bridge, voltage) - Set up devices - Develop Methods and procedures - Modell systems and analyse uncertainties - Validate by (pan-european) comparison 5

6 The structure of EMRP-JRP-IND09 traceable dynamic measurement of mechanical quantities Documentary standards Dissemination methods Description of the measuring chain for dynamic applications Transducer modeling Amplifier modeling Data analys. & Uncertainty 6 Mech. Facilities & Methods Electr. Facilities & Methods Mathematical Tools

7 Highlights: EMRP Project HLT01 EARS Metrology for a universal ear simulator and perception of non-audible sound 7

8 Motivation and need Limited understanding of perception of non-audible sound: little known about hazard and lack of rationale for exposure limits No measurement methods and standard for determination of exposure on humans for >20 khz Ear simulators are developed mainly for pure tones and only for adults: Need for particular devices for children and newborns Existing devices and protocols are complex: extension needs new approach for cost reduction and flexible application Vision of the project Improvement of preventative strategies for hearing conservation: Better quality of life 8

9 Workpackages WP1: Measurement technology for determination of brain responses WP3: Brain response thresholds and hearing thresholds for nonaudible sound WP2: Quantitative characterization of non-audible sound WP4: Design of a wideband universal ear simulator WP6: Impact Thresholds Safety Papers Standards Dissemination WP7: Management WP5: Test and validation of the universal ear simulator and determination of reference data 9

10 Consortium Consortium of 6 NMIs, PTB is working as coordinator Accompanied: 10 collaborators Current status Start at 1 May 2012, all contract signing finished Kick-off meeting was held at 15 / 16 May in Braunschweig 10 First working steps are running with no delay

11 Impact Set exposure limits for rationally based safety requirements for manufacturers, health and safety agencies, patients, workers, and employers Reduce unnecessary introduction of requirements for sound protection of products Improve reliability and quality of screening results for newborns Improve effectiveness, simplicity, remove ambiguity and thus reduce costs of audiometer calibration 11

12 EMRP 2012 Proposals EMRP SRT-s01: Realisation, dissemination and application of the unit watt in airborne sound. EMRP SRT-s02: Optical standards for the traceable characterisation of dynamic pressure fields. 12

EURAMET TC-AUV Report to CCAUV11

EURAMET TC-AUV Report to CCAUV11 CCAUV/17-52 EURAMET TC-AUV Report to CCAUV11 Stephen Robinson BIPM, Paris 21 22 September 2017 2 Report to CCAUV11, EURAMET TC-AUV Summary TC-AUV Introduction General activities Current projects EURAMET

More information

Physikalisch-Technische Bundesanstalt

Physikalisch-Technische Bundesanstalt CCAUV/15-05 Status Report PTB Physikalisch-Technische Bundesanstalt Short Report for CCAUV, October 2015 1. Organisation PTB is the National Metrology Institute of Germany and the highest technical authority

More information

Physikalisch-Technische Bundesanstalt

Physikalisch-Technische Bundesanstalt Physikalisch-Technische Bundesanstalt Short Report for CCAUV, September2017 1. Organisation PTB is the National Metrology Institute of Germany and the highest technical authority for the field of metrology

More information

39th Annual UIA Symposium. Metrology research for External Beam Cancer Therapy. K.-V. Jenderka

39th Annual UIA Symposium. Metrology research for External Beam Cancer Therapy. K.-V. Jenderka 39th Annual UIA Symposium Metrology research for External Beam Cancer Therapy K.-V. Jenderka P B Physikalisch-Technische Bundesanstalt Braunschweig Department Sound www.ptb.de Topics Overview Therapeutic

More information

INVESTIGATION OF PERCEPTION AT INFRASOUND FRE- QUENCIES BY FUNCTIONAL MAGNETIC RESONANCE IM- AGING (FMRI) AND MAGNETOENCEPHALOGRAPHY (MEG)

INVESTIGATION OF PERCEPTION AT INFRASOUND FRE- QUENCIES BY FUNCTIONAL MAGNETIC RESONANCE IM- AGING (FMRI) AND MAGNETOENCEPHALOGRAPHY (MEG) INVESTIGATION OF PERCEPTION AT INFRASOUND FRE- QUENCIES BY FUNCTIONAL MAGNETIC RESONANCE IM- AGING (FMRI) AND MAGNETOENCEPHALOGRAPHY (MEG) Martin Bauer, Tilmann Sander-Thömmes, Albrecht Ihlenfeld Physikalisch-Technische

More information

Consultative Committee for Acoustics, Vibration and Ultrasound CCAUV

Consultative Committee for Acoustics, Vibration and Ultrasound CCAUV Consultative Committee for Acoustics, Vibration and Ultrasound CCAUV Dr. Takashi USUDA on behalf of Prof. Dr Joaquín Valdés CCAUV President and CIPM member (UNSAM Argentina) 25 th meeting of the CGPM AUV

More information

Metrology Thought Leader

Metrology Thought Leader Acoustics, Ultrasound and Vibration (AUV) Section: Metrology Thought Leader Customer Newsletter July 2017 In this issue: Acoustics, Ultrasound and Vibration (AUV) Section: Laboratory Employee Profile AUV

More information

IEC/TC 29 Electroacoustics. Status: September 2010

IEC/TC 29 Electroacoustics. Status: September 2010 IEC/TC 29 Electroacoustics Status: September 2010 Secretary: Leif Nielsen Danish Standards Association Kollegievej 6 DK-2920 Charlottenlund Denmark Email address: len@ds.dk Chairman: Susan Dowson National

More information

t Newsletter No Ears Project Welcome C o n t e n t s Welcome Preface of the coordinator News & facts Latest news

t Newsletter No Ears Project Welcome C o n t e n t s Welcome Preface of the coordinator News & facts Latest news Ears Project t Newsletter No C o n t e n t s Welcome Preface of the coordinator News & facts Latest news Highlights Measurement of hearing thresholds at ultrasound frequencies Second prototype of ear simulator

More information

IEC 87: Ultrasonics Overview update July 2002

IEC 87: Ultrasonics Overview update July 2002 - 1 - CCAUV/02-07 IEC 87: Ultrasonics Overview update July 2002 Roy C Preston Secretary IEC TC 87: Ultrasonics British Electrotechnical Committee, British Standards Institution, 389 Chiswick High Road,

More information

Publishable JRP Summary Report for JRP HLT11 MetroMRT Metrology for Molecular Radiotherapy Background

Publishable JRP Summary Report for JRP HLT11 MetroMRT Metrology for Molecular Radiotherapy Background Publishable JRP Summary Report for JRP HLT11 MetroMRT Metrology for Molecular Radiotherapy Background The medical treatment modality of molecular radiotherapy (MRT), or nuclear medicine therapy, has been

More information

3M Center for Hearing Conservation

3M Center for Hearing Conservation 3M Center for Hearing Conservation Key Terms in Occupational Hearing Conservation Absorption A noise control method featuring sound-absorbing materials that are placed in an area to reduce the reflection

More information

Organisation Internationale de Métrologie Légale

Organisation Internationale de Métrologie Légale Organisation Internationale de Métrologie Légale OIML INTERNATIONAL RECOMMENDATION Equipment for speech audiometry Appareils pour l audiométrie vocale OIML R 122 Edition 1996 (E) CONTENTS Foreword... 3

More information

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL RECOMMENDATION OIML R 122 Annex C Edition 1999 (E) Equipment for speech audiometry Annex C Test report format Appareils pour l audiométrie vocale Annexe C Format du rapport d essai OIML R

More information

Highlights from TC-IR

Highlights from TC-IR Highlights from TC-IR Ulrike Ankerhold, PTB TC-IR chair 10 th General Assembly, Plenary Session Oslo, Norway, 24 to 25 May 2016 Highlights from TC-IR Health EMRP projects (Health Call 2011; ended by April/May

More information

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998 INTERNATIONAL STANDARD IS0 8253-l First edition 1989-11-15 COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO 8253-1:1998 Acoustics - Audiometric test methods - Part I: Basic

More information

Signals, systems, acoustics and the ear. Week 1. Laboratory session: Measuring thresholds

Signals, systems, acoustics and the ear. Week 1. Laboratory session: Measuring thresholds Signals, systems, acoustics and the ear Week 1 Laboratory session: Measuring thresholds What s the most commonly used piece of electronic equipment in the audiological clinic? The Audiometer And what is

More information

Hearing Conservation Program

Hearing Conservation Program Hearing Conservation Program Revised: September 2017 2009-2017. University of New Hampshire Office of Environmental Health and Safety. All rights reserved. The most current version of this document can

More information

Ears II Project Newsletter No 2. Welcome. C o n t e n t s. Welcome Preface of the coordinator. News & facts Latest news

Ears II Project Newsletter No 2. Welcome. C o n t e n t s. Welcome Preface of the coordinator. News & facts Latest news C o n t e n t s Welcome Preface of the coordinator News & facts Latest news Highlights Universal ear simulator Reference ultrasound work place Special sources MEMS arrays Dissemination Presentations at

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ACOUSTICS, ULTRASOUND AND VIBRATION METROLOGY

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ACOUSTICS, ULTRASOUND AND VIBRATION METROLOGY CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ACOUSTICS, ULTRASOUND AND VIBRATION METROLOGY Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Revised By:

More information

Status report of INMETRO to the 11 th CCAUV meeting

Status report of INMETRO to the 11 th CCAUV meeting CCAUV/17-17 Status report of INMETRO to the 11 th CCAUV meeting September, 2017 This report presents a brief synthesis of the current status and presents some activities developed by Inmetro in the fields

More information

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs. INTRODUCTION TO PURE TONE AUDIOMETERY (AUDIOMETER & TESTING ENVIRONMENT) By Mrs. Wedad Alhudaib with many thanks to Mrs. Tahani Alothman Topics : This lecture will incorporate both theoretical information

More information

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1.

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1. DEUTSCHER KALIBRIERDIENST Guideline DKD-R 6-2 Part 1 Calibration of Measuring Devices for Vacuum Fundamentals Edition 03/2002 Page 1 of 6 Published by the Accreditation Body of the Deutscher Kalibrierdienst

More information

Delaware State University

Delaware State University Delaware State University University Area Responsible: Risk and Safety Management Policy Number and Name: 7-09: Hearing Conservation Policy Approval Date: 7/28/11 Revisions: 8/8/2013 Reviewed: 7/26/2013

More information

Hearing Conservation Program

Hearing Conservation Program California State University, Chico Department of Environmental Health and Safety TABLE OF CONTENTS Section 1.0 Introduction... 1-1 2.0 Exposure Limites for Noise... 2-1 2.1 Protection... 2-1 2.2 Levels

More information

Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003

Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003 Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003 1. Purpose 1.1. The purpose of this procedure is to establish a TVA Hearing Conservation Program (HCP)

More information

Hearing Lectures. Acoustics of Speech and Hearing. Subjective/Objective (recap) Loudness Overview. Sinusoids through ear. Facts about Loudness

Hearing Lectures. Acoustics of Speech and Hearing. Subjective/Objective (recap) Loudness Overview. Sinusoids through ear. Facts about Loudness Hearing Lectures coustics of Speech and Hearing Week 2-8 Hearing 1: Perception of Intensity 1. Loudness of sinusoids mainly (see Web tutorial for more) 2. Pitch of sinusoids mainly (see Web tutorial for

More information

The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST

The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial Science and Technology

More information

Status report of KRISS AUV for the 11 th CCAUV meeting

Status report of KRISS AUV for the 11 th CCAUV meeting CCAUV/17-29 Status report of KRISS AUV for the 11 th CCAUV meeting 1. Organization September 2017 Korea Research Institute of Standards and Science (KRISS) 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic

More information

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment Masahiro Yoshioka National Metrology Institute of Japan (NMIJ) National

More information

General about Calibration and Service on Audiometers and Impedance Instruments

General about Calibration and Service on Audiometers and Impedance Instruments General about Calibration and Service on Audiometers and Impedance Instruments Calibration and Service of Audiometers - page 1 of 14 Rev.4 2008-05-21/JF General about Calibration and Service on Audiometers

More information

Investigation on high-frequency noise in public space.

Investigation on high-frequency noise in public space. Investigation on high-frequency noise in public space. Mari UEDA 1 ; Atsushi OTA 2 ; Hironobu TAKAHASHI 3 1 Aviation Environment Research Center, Japan 2 Yokohama National University, Japan 3 Advanced

More information

2015 APMP Meeting TCRI Report

2015 APMP Meeting TCRI Report 2015 APMP Meeting TCRI Report Nov. 3, 2014 Chul-Young Yi TCRI Chair Beijing, China 1 I. 2014 TCRI workshop Participants 10 NMIs, 33 participants ARPANSA, ANSTO, INER, NMC, NMIJ, NIM, PTKMR-BATAN, OAP,

More information

Craven Community College HEARING CONSERVATION PROGRAM

Craven Community College HEARING CONSERVATION PROGRAM Craven Community College HEARING CONSERVATION PROGRAM 1. PURPOSE 1.1 The purpose of this program is to provide guidelines for employees exposed to occupational noise and to comply with the OSHA Occupational

More information

Auditory cortex activation by infrasonic and lowfrequency sound of equalized individual loudness

Auditory cortex activation by infrasonic and lowfrequency sound of equalized individual loudness Auditory cortex activation by infrasonic and lowfrequency sound of equalized individual loudness Robert Kühler, Johannes Hensel, Christian Koch Physikalisch-Technische Bundesanstalt (PTB), Braunschweig,

More information

Hearing Conservation Program

Hearing Conservation Program Last Reviewed Date: 3/07/2018 Last Revised Date: 7/27/2017 Effective Date: 6/27/1994 Applies To: Employees, Faculty, Students, Others For More Information contact: EHS, Coordinator at 860-486-3613 or valerie.brangan@uconn.edu

More information

HEARING CONSERVATION PROGRAM

HEARING CONSERVATION PROGRAM CALIFORNIA STATE UNIVERSITY, CHICO HEARING CONSERVATION PROGRAM PREPARED BY THE OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY REVISED June 2008 TABLE OF CONTENTS Section Page 1.0 Introduction... 1-1 2.0 Exposure

More information

Introduction to Audiology: Global Edition

Introduction to Audiology: Global Edition Introduction to Audiology For these Global Editions, the editorial team at Pearson has collaborated with educators across the world to address a wide range of subjects and requirements, equipping students

More information

HiFFUT A New Class of Transducer

HiFFUT A New Class of Transducer HiFFUT A New Class of Transducer Kick-Off Meeting Dr Andrew Feeney, Postdoctoral Research Fellow My Background I obtained a Master s degree in Mechanical Engineering from the University of Glasgow in 2010

More information

Hearing Conservation Program April 27, 2018

Hearing Conservation Program April 27, 2018 Hearing Conservation Program April 27, 2018 1.0 INTRODUCTION 1.1 Purpose The purpose of the Indiana University Hearing Conservation Program is to prevent occupational noise exposures which could lead to

More information

INDH 5131 Controls of Occupational Hazards. Noise & Hearing Conservation. Part II. V. Audiometric Testing

INDH 5131 Controls of Occupational Hazards. Noise & Hearing Conservation. Part II. V. Audiometric Testing INDH 5131 Controls of Occupational Hazards Noise & Hearing Conservation Part II By: Magdy Akladios, PhD, PE, CSP, CPE, CSHM V. Audiometric Testing Equal Loudness Contours (Fletcher-Munsen Curves) 1 Testing

More information

SUBJECT: Physics TEACHER: Mr. S. Campbell DATE: 15/1/2017 GRADE: DURATION: 1 wk GENERAL TOPIC: The Physics Of Hearing

SUBJECT: Physics TEACHER: Mr. S. Campbell DATE: 15/1/2017 GRADE: DURATION: 1 wk GENERAL TOPIC: The Physics Of Hearing SUBJECT: Physics TEACHER: Mr. S. Campbell DATE: 15/1/2017 GRADE: 12-13 DURATION: 1 wk GENERAL TOPIC: The Physics Of Hearing The Physics Of Hearing On completion of this section, you should be able to:

More information

IMPLANTABLE BONE-CONDUCTION AND BONE-ANCHORED HEARING AIDS

IMPLANTABLE BONE-CONDUCTION AND BONE-ANCHORED HEARING AIDS Coverage for services, procedures, medical devices and drugs are dependent upon benefit eligibility as outlined in the member's specific benefit plan. This Medical Coverage Guideline must be read in its

More information

The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST

The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial Science and Technology

More information

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry.

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry. The design and development of a force comparator standard machine to provide national traceability in force measurement to industry. Speaker/ Author: S. Dlamini Co-author: C. Gouws National Metrology Institute

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 389-8 First edition 2004-05-15 Acoustics Reference zero for the calibration of audiometric equipment Part 8: Reference equivalent threshold sound pressure levels for pure tones

More information

Vision Painting Inc. Safety Management System

Vision Painting Inc. Safety Management System HEARING / NOISE CONSERVATION 1. INTRODUCTION Written in 1983, the OSHA Hearing Conservation Standard (29CFR1910.95 Occupational Noise Exposure) requires that employers implement a hearing conservation

More information

Legal metrology and standardization: an effective cooperation in acoustics

Legal metrology and standardization: an effective cooperation in acoustics OVERVIEW - OIML TC 13 Legal metrology and standardization: an effective cooperation in acoustics KLAUS BRINKMANN and UTZ RICHTER Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany 1 Acoustics

More information

Hearing Conservation Program

Hearing Conservation Program 1500 - Hearing Conservation Program DOCUMENT HISTORY Version Date Comments 1.0 January, 2016 Initial Hearing Conservation Program 2.0 July, 2017 Annual Review This document will be reviewed routinely and

More information

SOLUTIONS Homework #3. Introduction to Engineering in Medicine and Biology ECEN 1001 Due Tues. 9/30/03

SOLUTIONS Homework #3. Introduction to Engineering in Medicine and Biology ECEN 1001 Due Tues. 9/30/03 SOLUTIONS Homework #3 Introduction to Engineering in Medicine and Biology ECEN 1001 Due Tues. 9/30/03 Problem 1: a) Where in the cochlea would you say the process of "fourier decomposition" of the incoming

More information

Hearing Conservation Program

Hearing Conservation Program Hearing Conservation Program Table of Contents I. Program Goals and Objectives... 2 II. Scope and Application... 2 III. Regulatory Authority and Related Information... 2 IV. Definitions... 2 V. Responsibilities...

More information

1. THEORY 1.1 Anatomy of the ear Describe the major components and functions of the peripheral auditory system.

1. THEORY 1.1 Anatomy of the ear Describe the major components and functions of the peripheral auditory system. (As an 1. THEORY 1.1 Anatomy of the ear Describe the major components and functions of the peripheral auditory system. 1.2 Causes of hearing loss List the common causes of hearing loss. 1.3 Types of hearing

More information

Metrology in pharmaceutical production

Metrology in pharmaceutical production Metrology in pharmaceutical production 22/05/2013 1 Metrology in pharmaceutical production Metrologidag 2013 Lorenzo Carli, Ph.D. lzcl@novonordisk.com Contributions from: Jan Lasson Andreasen (R&D) Kirsten

More information

Health, Safety, Security and Environment

Health, Safety, Security and Environment Document owner and change code Document Owner Aaron Perronne Title HSSE Manager Mark X Change Code Description X N/A First Issue A Typographical/Grammatical correction; formatting change; text clarification-no

More information

The Safety and Health at Work Act 2005

The Safety and Health at Work Act 2005 The Safety and Health at Work Act 2005 The Workplace (Noise) Regulations 2007 The Minister in exercise of the powers conferred on him in section 105 of the Safety and Health at Work Act, makes the following

More information

Audiology Curriculum Post-Foundation Course Topic Summaries

Audiology Curriculum Post-Foundation Course Topic Summaries Audiology Curriculum Post-Foundation Course Topic Summaries Speech and Language Speech and Language Acquisition HUCD 5150 This course acquaints students with current theories of language development, the

More information

PC BASED AUDIOMETER GENERATING AUDIOGRAM TO ASSESS ACOUSTIC THRESHOLD

PC BASED AUDIOMETER GENERATING AUDIOGRAM TO ASSESS ACOUSTIC THRESHOLD Volume 119 No. 12 2018, 13939-13944 ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu PC BASED AUDIOMETER GENERATING AUDIOGRAM TO ASSESS ACOUSTIC THRESHOLD Mahalakshmi.A, Mohanavalli.M,

More information

Model Safety Program

Model Safety Program Model Safety Program DATE: SUBJECT: Occupational Noise Exposure Program REGULATORY STATUTE: OSHA 29 CFR 1910.95 RESPONSIBILITY: The company Safety Officer is. He/she is solely responsible for all facets

More information

Current Status of Ultrasonic Device Calibration in China

Current Status of Ultrasonic Device Calibration in China APMP TCAUV - Changsha Current Status of Ultrasonic Device Calibration in China YANG Ping, NIM E-mail: yangp@nim.ac.cn 1 2 3 5 6 Contents 1 Ultrasound Power 2.1 Ultrasound Field Hydrophone Calibration

More information

(b) is as low as is reasonably practicable, where it is not reasonably practicable to meet the standard under clause (a).

(b) is as low as is reasonably practicable, where it is not reasonably practicable to meet the standard under clause (a). PART 12 HEARING CONSERVATION AND NOISE CONTROL Sound control design 12.1 An employer must ensure that a new workplace, a significant physical alteration, renovation or repair to an existing workplace or

More information

THE 75 db(a) THRESHOLD LEVEL OF THE PHYSICAL AGENTS DIRECTIVE: A FLAWED EVOLUTION

THE 75 db(a) THRESHOLD LEVEL OF THE PHYSICAL AGENTS DIRECTIVE: A FLAWED EVOLUTION Proceedings of the Institute of Acoustics Volume 22, Part 5, 2000 pages 61-68 THE 75 db(a) THRESHOLD LEVEL OF THE PHYSICAL AGENTS DIRECTIVE: A FLAWED EVOLUTION B W Lawton Institute of Sound and Vibration

More information

NOISE & HEARING CONSERVATION PROGRAM YALE UNIVERSITY

NOISE & HEARING CONSERVATION PROGRAM YALE UNIVERSITY Yale University Environmental Health and Safety NOISE & HEARING CONSERVATION PROGRAM YALE UNIVERSITY Revised: June 2017 Environmental Health & Safety TABLE OF CONTENTS SECTION 1. NOISE AND HEARING CONSERVATION

More information

HEARING CONSERVATION PURPOSE

HEARING CONSERVATION PURPOSE HEARING CONSERVATION PURPOSE The purpose of a Hearing Conservation Policy (HCP) is to prevent occupational noise exposures which could lead to noise-induced hearing loss and to comply with existing Occupational

More information

Hearing Conservation Program Regulations and Recommendations Summary

Hearing Conservation Program Regulations and Recommendations Summary ITEM # OSHA 29 CFR 1910.95 MSHA 30 CFR Part 62 NIOSH DHHS Pub. No. 98-126 NOISE MEASUREMENT NOISE MEASUREMENT NOISE MEASUREMENT 1 Methods: Not specified Not specified Conform to ANSI S12.19-1996 without

More information

Educational Module Tympanometry. Germany D Germering

Educational Module Tympanometry. Germany D Germering Educational Module anometry PATH medical Germany D-82110 Germering Our educational modules 1 are made for providing information on how the hearing organ works and which test procedures are used to test

More information

Later-amplified NOW Later-amplified THEN Early compared to pre-unhs Delayed onset hearing loss Less hearing loss Mild hearing loss Average age of ID

Later-amplified NOW Later-amplified THEN Early compared to pre-unhs Delayed onset hearing loss Less hearing loss Mild hearing loss Average age of ID Conflict of Interest Disclosure Maximizing auditory development outcomes in children with hearing loss Ryan McCreery, PhD ryan.mccreery@boystown.org Research presented here was supported by the National

More information

BEAUFORT COUNTY COMMUNITY COLLEGE OCCUPATIONAL NOISE

BEAUFORT COUNTY COMMUNITY COLLEGE OCCUPATIONAL NOISE BEAUFORT COUNTY COMMUNITY COLLEGE OCCUPATIONAL NOISE A. Purpose... 1 B. Objective... 1 C. Scope... 1 D. Noise Level Monitoring and Evaluation... 2 E. Noise Control... 3 F. Audiometric Testing... 4 G. Hearing

More information

Before taking field measurements, it is important to determine the type of information required. The person making the measurement must understand:

Before taking field measurements, it is important to determine the type of information required. The person making the measurement must understand: Why measure noise in the workplace? Measuring noise levels and workers' noise exposures is the most important part of a workplace hearing conservation and noise control program. It helps identify work

More information

East Carolina University

East Carolina University East Carolina University Office of Environmental Health & Safety 211 S Jarvis Street, Suite 102 Greenville, NC 27858 P: (252) 328-6166 F: (252) 737-1458 www.ecu.edu/oehs Hearing Conservation Program ii

More information

Neuro-Audio Version 2010

Neuro-Audio Version 2010 ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE ECochG MLR P300 Neuro-Audio Version 2010 one device for all audiological tests Auditory brainstem response (ABR)/Brainstem evoked response audiometry (BERA)

More information

CERTIFICATE OF COMPETENCE IN WORKPLACE NOISE RISK ASSESSMENT

CERTIFICATE OF COMPETENCE IN WORKPLACE NOISE RISK ASSESSMENT CERTIFICATE OF COMPETENCE IN WORKPLACE NOISE RISK ASSESSMENT Entry Requirements The Institute of Acoustics is committed to an open access policy. The main principle is to admit all who will benefit from

More information

Hearing Conservation Services Specifications

Hearing Conservation Services Specifications Hearing Conservation Services Specifications FACILITIES AND EQUIPMENT The following equipment is used in assessing hearing, middle ear function and noise levels: - Maico MA40 audiometer - Maico MA41 audiometer

More information

Procedure. Procedure

Procedure. Procedure Procedure 4.1526 Occupational Noise Hearing Conservation Procedure A. Purpose... 1 B. Objective... 1 C. Scope... 1 D. Noise Level Monitoring and Evaluation... 2 E. Noise Control... 3 F. Audiometric Testing...

More information

Purpose: To provide a process to protect employees from hearing loss caused by excessive occupational exposure to noise.

Purpose: To provide a process to protect employees from hearing loss caused by excessive occupational exposure to noise. CNM WAY PROCESS CNM Process Name Hearing Conservation Program (03/30/2018 Revision) Overview of Hearing Conservation Program Purpose: To provide a process to protect employees from hearing loss caused

More information

SUNY Cortland Environmental Health and Safety Office Hearing Conservation Program

SUNY Cortland Environmental Health and Safety Office Hearing Conservation Program SUNY Cortland Environmental Health and Safety Office Hearing Conservation Program Inception Date: Not Specified Latest Revision/Review Date: August 1, 2018 Previous Revision/Review Date: June 28, 2017

More information

Hearing Conservation Program. Santa Clara University 500 El Camino Real Santa Clara, CA 95053

Hearing Conservation Program. Santa Clara University 500 El Camino Real Santa Clara, CA 95053 Hearing Conservation Program Santa Clara University 500 El Camino Real Santa Clara, CA 95053 December 10, 2013 Program Approval Signature on file in the EHS Office 5/19/10 Signature Date Joe Sugg Assistant

More information

Environmental Health and Safety. Hearing Conservation Program

Environmental Health and Safety. Hearing Conservation Program Environmental Health and Safety Hearing Conservation Program Date of Issuance: 07/23/2018 Revision Number: Initial Revision Date: Prepared by: EH&S 1. Purpose Carnegie Mellon University (CMU) has developed

More information

Hearing Conservation Program

Hearing Conservation Program Hearing Conservation Program June 2018 Hearing Conservation Program Table of Contents I. Purpose II. III. Responsibilities Program Directives A. Noise Exposure Monitoring B. Audiometric Testing C. Control

More information

A Guide for Choosing the Right Calibration for Torque Transducers

A Guide for Choosing the Right Calibration for Torque Transducers P1.9 A Guide for Choosing the Right Calibration for Torque Transducers Wegener, Georg / Stenner, Lioba Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt 1. Introduction Torque transducers

More information

Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement

Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement 1 of 10 Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement Revision Date Reviewed By Approved By Summary: This document outlines the function test procedure for a piezoelectric accelerometer

More information

Noise at Work Regulations. Mick Gray MRSC, LFOH, ROH. MWG Associates Ltd

Noise at Work Regulations. Mick Gray MRSC, LFOH, ROH. MWG Associates Ltd Noise at Work Regulations Mick Gray MRSC, LFOH, ROH. MWG Associates Ltd The Issue NIHL is a significant occupational disease 170,000 people in the UK suffer deafness, tinnitus or other ear conditions as

More information

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300 ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300 Neuro-Audio one device for all audiological tests Auditory brainstem response (ABR)/Brainstem evoked response audiometry (BERA) (air and

More information

Hearing Conservation Program. Southwestern Community College. Office of Human Resources

Hearing Conservation Program. Southwestern Community College. Office of Human Resources Hearing Conservation Program Southwestern Community College Office of Human Resources Revised January 26, 2005 Southwestern Community College 1. PURPOSE HEARING CONSERVATION PROGRAM 1.1 The purpose of

More information

Reference: Mark S. Sanders and Ernest J. McCormick. Human Factors Engineering and Design. McGRAW-HILL, 7 TH Edition. NOISE

Reference: Mark S. Sanders and Ernest J. McCormick. Human Factors Engineering and Design. McGRAW-HILL, 7 TH Edition. NOISE NOISE NOISE: It is considered in an information-theory context, as that auditory stimulus or stimuli bearing no informational relationship to the presence or completion of the immediate task. Human ear

More information

THE EAR Dr. Lily V. Hughes, Audiologist

THE EAR Dr. Lily V. Hughes, Audiologist WHY AM I HERE? HEARING & THE BRAIN THE EAR Dr. Lily V. Hughes, Audiologist Fairbanks Hearing & Balance Center at the ENT Clinic 1 out of every 5 adults has hearing loss. That s more than 48 million people

More information

CONVENTIONAL AND DIGITAL HEARING AIDS

CONVENTIONAL AND DIGITAL HEARING AIDS CONVENTIONAL AND DIGITAL HEARING AIDS Coverage for services, procedures, medical devices and drugs are dependent upon benefit eligibility as outlined in the member's specific benefit plan. This Medical

More information

AUDIOMETERS AUDIXI 10

AUDIOMETERS AUDIXI 10 AUDIOMETERS AUDIXI 10 DESCRIPTION The Audixi 10 is a Two-Channel innovative digital audiometer with Internet connectivity leveraging the Tablet technology and incorporating a new and simplified calibration

More information

Speech perception in individuals with dementia of the Alzheimer s type (DAT) Mitchell S. Sommers Department of Psychology Washington University

Speech perception in individuals with dementia of the Alzheimer s type (DAT) Mitchell S. Sommers Department of Psychology Washington University Speech perception in individuals with dementia of the Alzheimer s type (DAT) Mitchell S. Sommers Department of Psychology Washington University Overview Goals of studying speech perception in individuals

More information

Marlene Bagatto & Anne Marie Tharpe. A Sound Foundation Through Early Amplification Conference Chicago, USA December 10, 2013

Marlene Bagatto & Anne Marie Tharpe. A Sound Foundation Through Early Amplification Conference Chicago, USA December 10, 2013 Marlene Bagatto & Anne Marie Tharpe A Sound Foundation Through Early Amplification Conference Chicago, USA December 10, 2013 Background Good consensus on the benefits of amplification for children with

More information

Air conduction hearing thresholds of young and older Japanese adults for pure tones from 125 Hz to 16 khz

Air conduction hearing thresholds of young and older Japanese adults for pure tones from 125 Hz to 16 khz TECHNICAL REPORT #2011 The Acoustical Society of Japan Air conduction hearing thresholds of young and older Japanese adults for pure tones from 125 Hz to 16 khz Kenji Kurakata 1;, Tazu Mizunami 1, Kazuma

More information

Week 2 Systems (& a bit more about db)

Week 2 Systems (& a bit more about db) AUDL Signals & Systems for Speech & Hearing Reminder: signals as waveforms A graph of the instantaneousvalue of amplitude over time x-axis is always time (s, ms, µs) y-axis always a linear instantaneousamplitude

More information

UNCONTROLLED IF PRINTED Hearing Conservation

UNCONTROLLED IF PRINTED Hearing Conservation 1.0 Purpose and Scope To establish guidelines for use at all Waupaca Foundry, Inc. facilities, preventing potential employee hearing loss due to occupational noise exposures. Each facility should review

More information

Baylor University Hearing Conservation Program OSHA 29 CFR

Baylor University Hearing Conservation Program OSHA 29 CFR Baylor University Hearing Conservation Program OSHA 29 CFR 1910.95 1 INTRODUCTION Hearing conservation is an important aspect of the overall safety and health program. Workplace noise, classroom noise,

More information

Hearing threshold measurements of infrasound combined with audio frequency sound

Hearing threshold measurements of infrasound combined with audio frequency sound 12th ICBEN Congress on Noise as a Public Health Problem Hearing threshold measurements of infrasound combined with audio frequency sound Elisa Burke 1, Johannes Hensel 1, Thomas Fedtke 1 1 Physikalisch-Technische

More information

Implantable Treatments for Different Types of Hearing Loss. Margaret Dillon, AuD Marcia Adunka, AuD

Implantable Treatments for Different Types of Hearing Loss. Margaret Dillon, AuD Marcia Adunka, AuD Implantable Treatments for Different Types of Hearing Loss Margaret Dillon, AuD Marcia Adunka, AuD Implantable Technologies Types of hearing loss Bone-anchored devices Middle ear implantation Cochlear

More information

Hearing Aids. Bernycia Askew

Hearing Aids. Bernycia Askew Hearing Aids Bernycia Askew Who they re for Hearing Aids are usually best for people who have a mildmoderate hearing loss. They are often benefit those who have contracted noise induced hearing loss with

More information

Publishable Summary for 15HLT06 MRTDosimetry Metrology for clinical implementation of dosimetry in molecular radiotherapy

Publishable Summary for 15HLT06 MRTDosimetry Metrology for clinical implementation of dosimetry in molecular radiotherapy Publishable Summary for 15HLT06 MRTDosimetry Metrology for clinical implementation of dosimetry in molecular radiotherapy Overview The overall aim of this project is to provide the metrology for the clinical

More information

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017 UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017 Table of Contents Purpose Applicable Regulations and Standards Responsibilities

More information

Strengthening Activity Measurement Quality in Radiation Protection from Metrological Science to Reliable End-user Application

Strengthening Activity Measurement Quality in Radiation Protection from Metrological Science to Reliable End-user Application Strengthening Activity Measurement Quality in Radiation Protection from Metrological Science to Reliable End-user Application Franz Josef Maringer a,b,c*, Robert Brettner-Messler a, Michael Kreuziger a

More information

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO THE AUDIOMETER PERFECT FOR EVERY PATIENT POPULATION GSI AUDIOSTAR PRO FAST AND EFFICIENT The GSI AudioStar Pro continues the tradition of excellence in clinical

More information