Jul05 Rev A
|
|
- Charlotte Manning
- 6 years ago
- Views:
Transcription
1 Engineering Report CORELINK* Mechanical Splice Jul05 Rev A 1. SCOPE This report describes testing performed on CORELINK* mechanical splices using Bellcore Specification TR-TSY (Splicing Systems For Singlemode Optical Fibers) as a guideline. All test were performed in house with the exception of vibration which was performed by Elite Electronics located in Franklin Park, Illinois. 2. OVERVIEW OF TESTING Specimens were exposed to: single mode insertion loss; multimode insertion loss; return loss; temperature cycling insertion loss; temperature cycling return loss; pull strength; water immersion; singlemode multiple insertion loss; vibration; and 900 micron torsion test Insertion Loss, Single Mode A. Test Equipment and Conditions Tests were performed by laboratory technicians under laboratory conditions. Splice loss tests were performed using the power method as defined in EIA RS See Figure 1 for test setup. Tests were performed at 1300 nm wavelength using a Siecor CME-1000 fiber optic attenuation test set. Temperature and humidity were normal ambient conditions. Two different fiber types were used: Corning singlemode fiber SMF-28 with CPC-3 coating (mode field diameter of 9.5 microns); and AT&T depressed cladding type fiber (mode field diameter of 8.7 microns). Cleaving was performed using a Fujikura CT-07BS cleaver. Figure 1 Singlemode Insertion Loss Test Setup - Similar and Dissimilar Fibers B. Insertion Loss, Identical Fibers 1. From a supply of 100 splices, 26 splices were randomly selected and tested. The system was setup with a direct fiber connection between the source and detector and an initial power reading taken. The fiber was then broken and the first insertion loss was recorded for each splice using the same fiber. Splices were made per Reliable Specification RLEC (CORELINK Fiber Optic Mechanical Splice Description and Installation). Loss was calculated using the initial power reading and the power reading after splicing using the following formula: db = 10Log 10 (P 2 /P 1 ) Where: P 1 = initial power reading P 2 = power reading after splice 2005 Tyco Electronics Corporation Harrisburg, PA All International Rights Reserved * Trademark 1 of 11 Indicates change LOC B
2 2. Test Results Splice losses were as follows: 9 splices <.050 db 12 splices >.050 db <.100 db 4 splices >.100 db <.150 db 1 splice >.150 db <.200 db See Figure 2 for histogram plot of these results which represent a mean splice loss of.057 db with a standard deviation of.025 db. Out of this test group, 96% of the splices were below.125 db. C. Insertion Loss, Dissimilar Fibers Figure 2 Singlemode Insertion Loss 1. Six new splices were selected and tested for splice loss for a total of 19 data points using the fibers described above. The source and detector were switched and 19 more data points were recorded. The data points represent a combination of first and multiple insertions. Multiple insertions were made by removing and replacing one of the two fibers in the splice. See Figure 1 for test setup. Splices were made per RLEC Power readings were obtained and calculated per the procedures in paragraph 2.1.B. 2. Test Results Loss measurements for AT&T to Corning fiber were as follows: 2 splices >.050 db <.100 db 5 splices >.100 db <.150 db 8 splices >.150 db <.200 db 4 splices >.200 db <.300 db Rev A 2 of 11
3 Loss measurements for Corning to AT&T fiber were as follows: 2 splices >.025 db <.050 db 3 splices >.050 db <.100 db 5 splices >.100 db <.150 db 4 splices >.150 db <.200 db 5 splices >.200 db <.300 db The theoretical nominal intrinsic loss for these two fibers is.034 db. This data represents for AT&T to Corning, an average loss of.108 db with 90% less than.22 db; and for Corning to AT&T, and average loss of.127 db with 90% less than.21 db. The intrinsic loss has been subtracted from the above data to obtain the averages Insertion Loss, Multimode Fiber A. Test Equipment and Conditions Test conditions were the same as those in paragraph 2.1.A. Tests were performed at 1300 nm wavelength using a General Fiber Optics series LED source and a 3M Photodyne 22LXC dual channel fiber optic multimeter. The fiber used was Berk-Tek duplex jumper cable with a mode field diameter of 62.5 microns. Cleaving was performed using a Fujikura CT-07BS cleaver. B. Insertion Loss Insertion loss tests for multimode fiber were performed in two different ways. In the first test, five first insertion were performed by concatenating the splices and measuring the loss after each splice. The second test involved multiple insertions on a single splice. Twenty splices were performed. See Figure 3 for test setup. Power readings were obtained using the same methods described in paragraph 2.1.B. with loss calculated using the formula also in paragraph 2.1.B. 1. First test results were as follows: Splice 1.00 db Splice 2.00 db Splice 3.01 db Splice 4.01 db Splice 5.01 db Figure 3 Multimode Insertion Loss Test Setup This represents a mean splice loss per splice of.002 db. Rev A 3 of 11
4 2. The second test results can be summarized as after 20 insertions, the insertion loss for each insertion varied between.00 db and.03 db Return Loss, Singlemode A. Test Equipment and Conditions Test conditions were the same as those in paragraph 2.1.A. See Figure 4 for test setup. Source used was a 3M Photodyne 1300 nm, 1700 series laser optical source driver, Model 9XT. Fiber used was Corning SMF-28. Couplers used were Amphenol Model B. Return Loss Figure 4 Return Loss Test Setup A total of 16 splices were tested for first insertion return loss. To establish an initial power reading, a measurement was taken on a bare fiber ending in gel. The loss measurements were then made by breaking the fiber and making 16 first insertion splices with the same fiber setup. Return loss was then calculated using the following formula: db = 10Log 10 (P r /P i ) Where: P r = reflected power reading P i = incident optical power The initial zero reading was 52 db. The first insertion results are as follows: Splice Number Return Loss (db) Splice Number Return Loss (db) This data can be summarized as having an average return loss of 48.4 db with a standard deviation of 3.81 db. Rev A 4 of 11
5 2.4. Temperature Cycling Insertion Loss A. Test Equipment and Conditions Temperature chamber was a Thermotron. Source, fiber and couplers were the same as in paragraph 2.3.A. Detector was the same as in paragraph 2.2.A. Chart recorder was a Gould strip recorder. See Figure 5 for test setup. B. Temperature Cycling Figure 5 Temperature Cycling Insertion Loss Test Setup Splices were subjected to 100 temperature cycles between -40 and 80/C with the rate of change at 1/C per minute and uncontrolled humidity. See Figure 6 for profile of temperature change as a function of time. Temperature and insertion loss were continuously monitored by a normalizing circuit and a continuous strip chart. Rev A 5 of 11
6 Figure 6 Temperature Cycling Profile Splice loss did not exceed.07 db variation from the initial reading at any point in the test. See Figure 7 for sample of the recording. Figure 7 Temperature Cycling Sample Rev A 6 of 11
7 2.5. Temperature Cycling Return Loss A. Test Equipment and Conditions Equipment used was the same as that used in paragraph 2.4.A.. See Figure 8 for test setup. B. Temperature Cycling Figure 8 Temperature Cycling Return Loss Test Setup Splices were subjected to 20 temperature cycles between -40 and 80/C with the rate of change at 1/C per minute and uncontrolled humidity. See Figure 6 for profile of temperature change as a function of time. Temperature and return loss were continuously monitored by a normalizing circuit and a continuous strip chart Pull Strength Testing showed that no point between -30 and 80/C did the return loss go below 50 db. Between -30 and -40/C, the return loss did not go below 40 db. A. Test Conditions and Equipment Test conditions and equipment was the same as that used in paragraph 2.1.A.. See Figure 9 for test setup. A Tinius Olsen Series 1000 tensile tester was used for pulling the fibers and reading force with a 100 pound load cell with a minimum load range of 5 pounds maximum scale. Loss versus load was plotted on a Tinius Olsen Series 1000 X-Y recorder. Rev A 7 of 11
8 Figure 9 Pull Strength Test Setup B. Pull Strength A total of 21 splices were made per RLEC A clamping mechanism was installed in the clamps of the pull tester that did not induce loss due to the clamp force applied to the fiber. Splices were made and an initial loss measurement taken. Fibers were then pulled at a rate of 1 inch per minute. Force versus loss was plotted, the point on the curve at which the loss increased was then recorded as the pull strength of the splice Water Immersion Pull Force (lb) Number of Splices >.5 <.75 1 >.75 < >.875 < > 1.0 < > < > 1.25 < > < This data represents a mean pull force of 1.09 pound with a standard deviation of.185 pound. A. Test Conditions and Equipment Test conditions and equipment was the same as that used in paragraph 2.4.A. with the exception that the splice was immersed in water in a container placed in the temperature chamber stabilized at 43/C. Splices were made per RLEC Rev A 8 of 11
9 B. Water Immersion The splice was made and insertion loss recorded. The splice was then placed in the temperature chamber and insertion loss was again recorded after the water stabilized to the chamber temperature. The splice remained in the temperature chamber for five days. The splice loss was again measured before removing the splice from the temperature chamber at the end of the five day period. Insertion loss was recorded continuously throughout the five day period. At the end of 24 hours and at the end of the five day period, the splice loss did not change from the initial reading taken before the splice was immersed in water Multiple Insertion A. Test Conditions and Equipment Test conditions and equipment was the same as that used in paragraph 2.1.A. See Figure 1 for test setup. B. Multiple Insertion Loss A total of 19 splices were randomly selected from a lot of 100 splices. Ten insertion loss measurements were made on each splice and recorded. Multiple insertion was made by opening the splice and removing and replacing one fiber. The fibers were always kept in the same angular orientation throughout the multiple insertions for each splice. Results can be summarized as the splice having 89% of the loss measurements below.2 db. See Figure 10 for a plot of the loss measurements. Rev A 9 of 11
10 Figure Vibration A. Test Conditions and Equipment Test was performed at room temperature. Source and detector was a Siecor CME-1000 attenuation test set. The vibration machine was an MB Model EL3600 with amplifier MB Model T451, Type 2 and control console HP Model 5427A. The accelerometer was Endevco Model 2233E. Splices were made per RLEC See Figure 11 for test setup. Rev A 10 of 11
11 Figure 11 Vibration Test Setup B. Vibration Six splices were secured to a fixture which in turn was rigidly attached to the moving element of the vibration machine. Splices were concatenated and splice loss was monitored during the test. Splices were vibrated in each of three mutually perpendicular axes over the frequency range of 10 to 55 Hz at a constant vibratory amplitude of 1.52 mm DA. Frequency range was traversed in one minute and was repeated 20 times in each axis. The change in splice loss did not change more than.05 db during the entire test Torsional Stress Resistance A. Test Conditions and Equipment Test conditions and equipment was the same as that used in paragraph 2.4.A. with the exception that six concatenated splices were used in place of a single splice. Splices were made per RLEC Fiber used was AT&T 900 micron. B. Torsional Stress Splice was made with 60 inches of fiber extending from both ends of the splice. These ends were secured to a splice tray and crossed over and figure eighted five times and stored on the tray. Splices were stored for seven days at room temperature and then placed in a temperature chamber and cycled per a standard twelve hour cycle for a total of 50 cycles. Splice loss was continuously recorded while temperature cycling the splice. Visual examination showed no evidence of physical damage with all fibers intact and not broken. The concatenated splice loss, which is the sum of insertion loss values for six splices, did not vary more than.3 db. Therefore, the average splice loss did not vary more than.05 db. Rev A 11 of 11
OPTICAL FIBER SPLICING. Courtesy from Significant Technologies Sdn Bhd
OPTICAL FIBER SPLICING Introduction Reason for jointing: - Increase fiber span (long cable runs) Connecting devices such as amplifiers, pigtails, etc. to fibers TYPES OF SPLICING Two types of splicing
More informationMass Fusion Splicing of Optical Fiber Ribbon Cables
Application Notes Mass Fusion Splicing of Optical Fiber Ribbon Cables Author Prasanna Pardeshi and Sudipta Bhaumik Issued January 2014 Abstract To build a fiber optic network, one may eventually join two
More informationSuccessful Splicing Made Easy
Successful Splicing Made Easy Years ago fiber splicing was a difficult and finicky process that was left to the fiber guru. The splicers were expensive and temperamental. Nobody wanted to be the person
More informationFusion Splicing Basics Do It Right The First Time! Keith Foord Product Manager Greenlee Communications
Fusion Splicing Basics Do It Right The First Time! Keith Foord Product Manager Greenlee Communications Attendee Announcements A1 Slide 2 A1 Subscribe section has been approved by Sarah on 5.9.17 Amy, 5/9/2017
More informationCorning SMF-28 Ultra Optical Fiber
Corning SMF-28 Ultra Optical Fiber Fusion Splice Verification Report AN0041 Issued: March 2014 OBJECTIVE Corning asked AFL to independently test the splicing performance of Corning s new SMF-28 Ultra optical
More informationFibrlok II 2529 Universal Optical Fiber Splice
Fibrlok II 2529 Universal Optical Fiber Splice Instructions October 2002 34-7035-4458-4-D Contents: 1.0 General...3 2.0 Splicing Set-up...4 3.0 Fiber Preparation...5 4.0 Splice Assembly...6 5.0 Fiber Repositioning...8
More informationWhite Paper Selecting the Correct Fusion Splicer for Your Application By: Keith Foord, Product Manager, Greenlee Communications
White Paper Selecting the Correct Fusion Splicer for Your Application By: Keith Foord, Product Manager, Greenlee Communications Introduction There are many variables to consider when selecting the correct
More informationInstructions. Fibrlok Optical Fiber Splicing System. Issue 6, August 1991
Instructions TM Fibrlok Optical Fiber Splicing System Issue 6, August 1991 1.0 General The 3M brand Fibrlok TM Optical Fiber Splicing System provides permanent mechanical splices for single or multi mode
More informationCampus & Data Centers Why Ribbon Technology Works for You
Campus & Data Centers Why Ribbon Technology Works for You Characteristics and Benefits of Ribbon Fiber & Ribbon Cables By Kurt Templeman, RCDD INDEX 1. Fiber Optic Specifications 2. Advantages of Standard
More informationGR-765-CORE Single Fiber Single-Mode Optical Splices and Splicing Systems Contents. Contents. Telcordia GR-765-Documentation Information
Telcordia GR-765-Documentation Information Generic Requirements Notice of Disclaimer...................... iii.......................................... v List of Figures..........................................
More informationAttendee Announcements
Attendee Announcements Seminar Raffle Be sure to drop your raffle ticket in the drum at today s Keynote located in the Mile High Ballroom. You have a chance to win a $250 American Express Gift Card. One
More informationCorning SMF-28 Ultra Optical Fiber Fusion Splicing Report
Ultra Fusion Splicing Report Application Note AN Issued: October 17 ISO 91 Registered Objective Corning routinely conducts fusion splicing studies for our optical fiber products. In this report Corning
More informationFilament Fusion Splicing Workstation
FFS-2000 Filament Fusion Splicing Workstation An Integrated System for Production and Specialty Fiber Splicing The FFS-2000 System The FFS-2000 is a complete workstation with all fusion splicing procedures
More informationINTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.
INTRODUCTION TO PURE TONE AUDIOMETERY (AUDIOMETER & TESTING ENVIRONMENT) By Mrs. Wedad Alhudaib with many thanks to Mrs. Tahani Alothman Topics : This lecture will incorporate both theoretical information
More informationAutomated Fusion Splicing of Circular and D-shaped Fiber with Elliptical Core
Automated Fusion Splicing of Circular and D-shaped Fiber with Elliptical Core Toshiki Kubo, 1 Bryan Malinsky, 1 Yoshiharu Kanda, 1 and Wenxin Zheng 1 A new method for splicing D-shaped and circular shaped
More informationInstructions. Fibrlok II Optical Fiber Splicing System. Issue 1, June 1992
Instructions TM Fibrlok II Optical Fiber Splicing System Issue 1, June 1992 Contents: 1.0 General... 1 2.0 Splicing Set-up... 3 3.0 Fiber Preparation... 4 4.0 Splice Assembly... 4 5.0 Fiber Repositioning...
More information24-Fiber Ribbon Fusion Splicer
24-Fiber Ribbon Fusion Splicer Toshiro Mizushima, Sachie Morita, Hiroshi Sugawara, Takeshi Sato and Shounosuke Yaguchi A small mass fusion splicer for splicing up to 24-fiber ribbon has been developed.
More informationFibrlok II 2529 Universal Optical Fiber Splice
Fibrlok II 2529 Universal Optical Fiber Splice Instructions January 2007 78-8128-0163-3-E Contents: 1.0 General... 3 2.0 Splicing Set-up... 4 3.0 Fiber Preparation... 5 4.0 Splice Assembly... 6 5.0 For
More informationDispersion Compensating Fibers with Improved Splicing Performance
Available online at www.sciencedirect.com ScienceDirect Physics Procedia 48 (2013 ) 96 101 The XIII International Conference on the Physics of Non-Crystalline Solids Dispersion Compensating Fibers with
More informationGeneral about Calibration and Service on Audiometers and Impedance Instruments
General about Calibration and Service on Audiometers and Impedance Instruments Calibration and Service of Audiometers - page 1 of 14 Rev.4 2008-05-21/JF General about Calibration and Service on Audiometers
More informationJun06 Rev A
Product Specification 108-2235 15Jun06 Rev A NETCONNECT* MRJ21 Gigabit Ethernet Cable Assemblies 1. SCOPE 1.1. Content This specification covers performance, test and quality requirements for NETCONNECT*
More informationHigh Strength splicing with Ericsson
High Strength splicing with Ericsson The High Strength Concept Fusion splicing technique has developed to such a degree that low loss splices have become the rule. However, the same cannot be said of
More informationInstallation Instructions
Installation Instructions 1View Manager 96 Enhanced OUCH RACKER Contents About his Document...1 Planning the OUCH RACKER Network...1 Backbone Network Guidelines...2 Star Network Guidelines...2 Installing
More informationRiGO801 Laboratory Requirements
RiGO801 Laboratory Requirements 2015-11-25 Air Conditioning According to EN 13032 1 and LM-79-08 the temperature in the environment of the DUT needs to be 25 C +/- 1 C during the measurement. EN 13032-4
More informationFT-302 Force Transducer
Technical Note FT-302 LabScribe is a trademark of 2015 Overview The FT-302 is a high-sensitivity dual-range research grade force transducer designed to measure forces in the 0.005 to 10 gram and 0 to 100
More informationOIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL RECOMMENDATION OIML R 122 Annex C Edition 1999 (E) Equipment for speech audiometry Annex C Test report format Appareils pour l audiométrie vocale Annexe C Format du rapport d essai OIML R
More informationLesson 9 Presentation and Display of Quantitative Data
Lesson 9 Presentation and Display of Quantitative Data Learning Objectives All students will identify and present data using appropriate graphs, charts and tables. All students should be able to justify
More informationCETR Adhesion Testing on Glass/Al Surface for Corning Inc.
CETR Adhesion Testing on Glass/Al Surface for Corning Inc. I. Introduction 1.1 Objective The goal of the study was to differentiate stiction from various glass composites and surface treatments using the
More informationStudy on the Influential Factors in the Fusion Splice Loss of SMF-28 and MP980 Fibers
, March 16-18, 2016, Hong Kong Study on the Influential Factors in the Fusion Splice Loss of and MP980 Fibers Pennapa Khamdee, Apichai Bhatranand, and Yuttapong Jiraraksopakun Abstract This paper presents
More informationAppendix B Approved Materials
WASHINGTON METROPOLITAN AREA TRANSIT AUTHORITY DEPARTMENT OF INFORMATION TECHNOLOGY NETWORK & COMMUNICATIONS SERVICES NETWORK COMMUNICATIONS DESIGN & WIRING STANDARDS Appendix B Approved Materials Item
More informationMPO Field Installable Connectors How & Why to Customize Exact Cable Builds with Emerging Solutions
MPO Field Installable Connectors How & Why to Customize Exact Cable Builds with Emerging Solutions J. Joshua Seawell Sumitomo Electric Lightwave Outline Still Moving 1G,10G 40G 100G?? Trends &P Projections
More informationBest Practices for Testing Fiber Optics in the Enterprise
Best Practices for Testing Fiber Optics in the Enterprise Osik Kwon Solution Engineer, PMP Korea office, VIAVI Solutions Agenda Quick review of some basics and standards End-face inspection and certification
More informationIS THAT SPLICE REALLY GOOD ENOUGH? IMPROVING FIBER OPTIC SPLICE LOSS MEASUREMENT
IS THAT SPLICE REALLY GOOD ENOUGH? IMPROVING FIBER OPTIC SPLICE LOSS MEASUREMENT NEMI Fiber Optic Splice Improvement Project Members: J. Meitzler, 3SAE; L.Wesson, Aurora; P. Arrowsmith and R. Suurmann,
More informationCOYOTE Flip Splice Trays for High Density Splice Applications
OCTOBER 08 COYOTE Flip Splice Trays for High Density Splice Applications Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product
More informationLION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:
LION PRECISION Application Note LA02-0061 March, 2013 Linear Position Measurement with Eddy-Current Sensors Position, Displacement Applicable Equipment: Eddy-Current position measurement systems. Applications:
More informationUser s manual for the FSU 995 FA single fiber fusion splicer by Ericsson
User s manual for the FSU 995 FA single fiber fusion splicer by Ericsson 1 2 Table of contents Introduction... 4 Safety Information... 5 Description of the FSU 995 FA... 6 Setting up the splicer... 8 BASIC
More informationWe bring quality to light. LGS 350 Goniophotometer
We bring quality to light. LGS 350 Goniophotometer The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight Accurate determination
More informationDECEMBER 21, 2007 TEST REPORT # REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF
DECEMBER 21, 2007 TEST REPORT #207814 REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF8-025-05.0-L-DV SAMTEC, INC. APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR
More informationHiFFUT A New Class of Transducer
HiFFUT A New Class of Transducer Project Meeting April 2017 Dr Andrew Feeney Study of the electro-mechanical behaviour of flexural ultrasonic transducers This work will help us to design HiFFUTs for particular
More informationMEGGITT SENSING SYSTEMS Endevco short course guide
MEGGITT SENSING SYSTEMS Endevco short course guide Shock and vibration measurement technology I Shock and vibration measurement technology II Instructors: Jon Wilson, Jon S. Wilson Consulting Michael Phan,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60601-2-37 2001 AMENDMENT 1 2004-08 Amendment 1 Medical electrical equipment Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring
More informationSep2018 Rev B1
Product Specification 12Sep2018 Rev B1 HD30 Series Connector System 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the TE Connectivity (TE) HD30 Series
More informationTesting Parallel Optics. Ed Gastle Product Manager Viavi Solutions
Testing Parallel Optics Ed Gastle Product Manager Viavi Solutions Agenda Quick review of some basics and standards End-face inspection and certification Fiber map Loss and polarity testing OTDR testing
More informationAssembly Instruction for Fiber Optic Series FOH Fischer Connectors
Assembly Instruction for Fiber Optic Series FOH Fischer Connectors Table des matières 1 Introduction... 3 2 Document history... 3 3 Definitions and Acronyms... 3 4 FOH Plugs & Receptacles with Potting
More informationInstallation of force transducers
Installation of force transducers Force transducers have reached a high technical standard in recent years. Transducers achieve part of their high accuracy due to improved possibilities for calibration.
More informationTorsion Property and Cyclic Fatigue Fracture Behavior of. Nickel-Titanium Endodontic Instruments
Key Engineering Materials Online: 2005-06-15 ISSN: 1662-9795, Vols. 288-289, pp 603-606 doi:10.4028/www.scientific.net/kem.288-289.603 2005 Trans Tech Publications, Switzerland Torsion Property and Cyclic
More informationLeakage Currents of Zinc Oxide Surge Arresters in 22 kv Distribution System Using Thermal Image Camera
Journal of Power and Energy Engineering, 2014, 2, 712-717 Published Online April 2014 in SciRes. http://www.scirp.org/journal/jpee http://dx.doi.org/10.4236/jpee.2014.24095 Leakage Currents of Zinc Oxide
More informationNew Core Alignment Fusion Splicer FSM-50S
New Core Alignment Fusion Splicer FSM-50S Shigeru Saito, Katsumi Sasaki, Kenji Takahashi, Koji Ohzawa, Taku Otani and Srachate Chumpol For many years, most fiber optic splicing in the core and edges of
More informationAcceptance testing of a large aperture dynamic wavefront sensor
Acceptance testing of a large aperture dynamic wavefront sensor David J. Fischer*, Alan Wertheimer, Laurie Hill Eastman Kodak Company, 1447 St. Paul St, Rochester, NY 14653 ABSTRACT A large aperture dynamic
More informationTHE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS
THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS THOMAS R. WATKINS, O. BURL CAVIN, CAMDEN R. HUBBARD, BETH MATLOCK, AND ROGER
More informationHD Flex Fiber Optic Cassettes SPECIFICATION SHEET
SPECIFICATION SHEET technical information HD Flex Fiber Optic Cassettes offer a wide array of deployment options to support both Ethernet and Fibre Channel networks. Cassette types are available with 1
More informationMove on from. based treatment
Product class Test items Diseases Tn-l CK-MB Myoglobin Thrombosis hs-crp Cardiovascular Inflammation PSA Prostate cancer AFP Liver cancer CEA Colorectal cancer Microalbumin HbA1c Cortisol Metabolism Total
More informationOrtronics Splice-On Connector Certification Program
Ortronics Splice-On Connector Certification Program TABLE OF CONTENTS PAGE 1.0 Understanding Splicing Technology...1 1.1 How a splicer works...1 1.2 V-Groove (Clad Alignment) vs. Core Alignment...2 1.3
More informationNOVIN medical engineering Co. Designer and manufacturer of physiotherapy equipment
NOVIN medical engineering Co. Designer and manufacturer of physiotherapy equipment NOVIN medical engineering Co. started its journey in the field of physiotherapy equipment in 1998. Using senior and experienced
More informationMEDIUM-FLOW PNEUMOTACH TRANSDUCER
MEDIUM-FLOW PNEUMOTACH TRANSDUCER SS11LA for MP3x and MP45 System TSD117 & TSD117-MRI for MP150/MP100 System RX117 Replacement Airflow Head See also: AFT series of accessories for airflow and gas analysis
More informationMeasurement of Mechanical Properties of Coronary Stents according to the European Standard pren
February 1999 45 Measurement of Mechanical Properties of Coronary Stents according to the European Standard pren 12006-3 W. SCHMIDT, P. BEHRENS, D. BEHREND, K.-P. SCHMITZ Institute for Biomedical Engineering,
More informationTechnical Data Sheet SONOFLOW CO.55/xxx(H) V2.0
The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on
More informationNova 3 Noise Attenuation Study
Nova 3 Noise Attenuation Study Prepared by: Mathew Bancroft (BE Mech Hons, Canterbury) Design Engineer RPB Safety Limited June 2012 Table of Contents 1.0 Introduction... 3 1.1 Noise Attenuation Data...
More informationDescriptions of NDT Projects Fall 2004 October 31, 2004
Descriptions of NDT Projects Fall 2004 October 31, 2004 Introduction There are two separate NDT labs in Magister: ULTRA for ultrasound and EDDY for eddy current. Both labs are equipped with mechanical
More information1. SCOPE ELIGIBILITY EXAMINATION CONTENT RENEWAL & RECERTIFICATION PROCEDURE ESSENTIAL READING...
Certification Services Division Newton Building, St George s Avenue Northampton, NN2 6JB United Kingdom Tel: +44(0)1604-893-811. Fax: +44(0)1604-893-868. E-mail: pcn@bindt.org PCN/GEN ISO 20807 Appendix
More informationDatasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors
Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA
More informationTesting FM Systems on the 7000 Hearing Aid Test System
Testing FM Systems on the 7000 Hearing Aid Test System Introduction Testing FM Systems on the 7000 Hearing Aid Test System This workbook describes how to test FM systems with the 7000 Hearing Aid Test
More information1 Service factor Determine the required service factor from tables 9 and 10 on pages 87 and 88.
SKF Couplings SKF Flex Couplings SKF Flex Couplings are designed to accommodate misalignment and shock loads and dampen vibration levels. These easy to install, maintenance-free couplings are available
More informationClinically Available Optical Topography System
Clinically Available Optical Topography System Clinically Available Optical Topography System 18 Fumio Kawaguchi Noriyoshi Ichikawa Noriyuki Fujiwara Yûichi Yamashita Shingo Kawasaki OVERVIEW: Progress
More informationElectromyography II Laboratory (Hand Dynamometer Transducer)
(Hand Dynamometer Transducer) Introduction As described in the Electromyography I laboratory session, electromyography (EMG) is an electrical signal that can be recorded with electrodes placed on the surface
More informationImpact of the ambient sound level on the system's measurements CAPA
Impact of the ambient sound level on the system's measurements CAPA Jean Sébastien Niel December 212 CAPA is software used for the monitoring of the Attenuation of hearing protectors. This study will investigate
More informationResearch of the spectral diffuse reflectance of melanoma in vivo
Research of the spectral diffuse reflectance of melanoma in vivo V.G. Petruk* a, D.B. Bolyuh b, S.M. Kvaternyuk a, O.E. Kvaternyuk c, Y.M. Denysiuk a, A. Kotyra d a Vinnytsia National Technical University,
More informationWarranty. Any attempt by an unauthorized person to alter or repair the product is also not covered by the warranty.
Warranty ii The Gentec-EO inc Holographic Beam Sampler carries a one year warranty (from date of shipment) against material and / or workmanship defects, when used under normal operating conditions. The
More informationInstruction manual. Fusion Splicer. 1st
1st Instruction manual Fusion Splicer Please read this instruction manual carefully before operating the equipment. Adhere to all safety instructions and warnings contained in this manual. Keep this manual
More informationGEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7
GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7 NOTICE: This document is version controlled and was produced as a part of the GEX Information Program which requires that all Series 100
More informationNuclear Associates
Nuclear Associates 37-013 GARD Users Manual March 2005 Manual No. 37-013-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective
More informationramé-hart Model 90 Goniometer / Tensiometer
World Leader in Surface Science Instruments Since 1961 www.ramehart.com ramé-hart shown with optional Fiber Optic Illuminator Upgrade ramé-hart ramé-hart is available in two variations: The Contact Angle
More informationYY Translated English of Chinese Standard: YY PHARMACEUTICAL INDUSTRY STANDARD
Translated English of Chinese Standard: YY0766-2009 www.chinesestandard.net Sales@ChineseStandard.net PHARMACEUTICAL INDUSTRY STANDARD YY OF THE PEOPLE S REPUBLIC OF CHINA ICS 11.040.70 C 41 YY 0766-2009
More informationS M A R T. tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free. Revolution in Diagnostics
S M A R T tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free Revolution in Diagnostics Conventional Diagnosis Patient visits the lab's local sample
More informationRibbon Splitting Tool (RST-000)
Ribbon Splitting Tool (RST-000) P/N 004-098 Issue 12 related literature Search www.corning.com/opcomm. Click on Resources. Slider button Latch 1. General Figure 1 1.1 This procedure describes how to divide
More informationPerformance of phased array and conventional ultrasonic probes on the new ISO reference block
Performance of phased array and conventional ultrasonic probes on the new ISO 19675 reference block C. Udell, D. Chai 1 and F. Gattiker Proceq S.A., Ringstrasse 2, Schwerzenbach, Switzerland. More info
More informationDirect Reading (Pocket) Dosimeter
Direct Reading (Pocket) Dosimeter What is a Pocket Dosimeter???? Direct Read Pocket Dosimeters are rugged, precision instruments about the size of a pocket fountain pen, which are used to measure accumulative
More informationDräger Alcotest 5510 Alcohol Screening Device
Dräger Alcotest 5510 Alcohol Screening Device The Dräger Alcotest 5510 handheld screener provides the quality, accuracy, and reliability that our customers have come to expect from our breath alcohol detection
More informationCORTEC Corporation. For: Behzad Bavarian California State University, Northridge, USA December 20, 2018
Laboratory Test to Evaluate the Vapor-Inhibiting Ability of Daubert NOX- RUST Vapor wrapper for Temporary Protection of Ferrous Surfaces after Exhaustion Test (MIL-STD-3010C) For: CORTEC Corporation By
More informationStandard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application 1
Designation: E1012 14 Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application 1 This standard is issued under the fixed designation
More informationSingle Use Curlew TM Multiple Biopsy Forceps
Single Use Curlew TM Multiple Biopsy Forceps 13 SPECIMEN WITH METAL STORAGE CYLINDER With In Situ Fixation, Batch or Single Specimen Collection US Patents 5,782,747; 5,980,468; 6,071,248; foreign patents
More informationBryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL
Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Table of Contents Bryan-DUmon Series II rigid bronchoscope 1. 2. 3. 4. 5. Diagram and Overview Universal Barrel Bronchial and
More informationImpact of Particle Mass Distribution on the Measurement Accuracy of Low-Cost PM-Sensors
Impact of Particle Mass Distribution on the Measurement Accuracy of Low-Cost PM-Sensors Bernd Laquai, 20.10.2017 Commodity PM-measurement devices are used more and more by citizens concerned about air
More informationChapter 7: Descriptive Statistics
Chapter Overview Chapter 7 provides an introduction to basic strategies for describing groups statistically. Statistical concepts around normal distributions are discussed. The statistical procedures of
More informationDissection and Contraction of Frog Heart
Dissection and Contraction of Frog Heart Rob MacLeod and Alex Brownell (aabrownell@yahoo.com) March 4, 2006 1 Purpose and Background 1.1 Purpose: To examine the anatomy and basic contractile physiology
More informationHEARING CONSERVATION PROGRAM
CALIFORNIA STATE UNIVERSITY, CHICO HEARING CONSERVATION PROGRAM PREPARED BY THE OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY REVISED June 2008 TABLE OF CONTENTS Section Page 1.0 Introduction... 1-1 2.0 Exposure
More informationMeasuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices
Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices By Zhang Feng, Senior Medical Applications Engineer Marten Smith, Medical Marketing Manager Medical Products Group Microchip
More informationHiFFUT A New Class of Transducer
HiFFUT A New Class of Transducer Kick-Off Meeting Dr Andrew Feeney, Postdoctoral Research Fellow My Background I obtained a Master s degree in Mechanical Engineering from the University of Glasgow in 2010
More informationIdentification. Eartips. Battery Door. 2-Position Switch. Eartip. Removal Cord. Flexible Neck Cord Protective Case. Filter Tool and Extra ACCU Filters
English User Manual Warnings Failure to follow these recommendations may severely reduce the amount of hearing protection provided by the earplugs. Earplugs comply with EN-352 standard of measurement.
More informationHuman LDL ELISA Kit. Innovative Research, Inc.
Human LDL ELISA Kit Catalog No: IRKTAH2582 Lot No: SAMPLE INTRODUCTION Human low-density lipoprotein (LDL) transports cholesterol from the liver to tissues where it is incorporated into cell membranes.
More informationWe bring quality to light. LGS 1000 Goniophotometer
We bring quality to light. LGS 1000 Goniophotometer Instrument description Measurement options Spatial radiation patterns Luminous flux integration Specifications Key features at a glance Goniophotometer
More informationImproving Headphone Fit Using Design Of Cable
Technical Disclosure Commons Defensive Publications Series October 27, 2017 Improving Headphone Fit Using Design Of Cable N/A Follow this and additional works at: http://www.tdcommons.org/dpubs_series
More informationTHE INFLUENCE OF IONS ON THE CONTRACTION OF ISOLATED EARTHWORM SMOOTH MUSCLE
THE INFLUENCE OF IONS ON THE CONTRACTION OF ISOLATED EARTHWORM SMOOTH MUSCLE BACKGROUND READING Animal Physiology by Hill, Wyse & Anderson, 2004: pp. 484 486. ANIMALS & EQUIPMENT Living material Large
More informationVistaCam ix Proof interchangeable head
VistaCam ix Proof interchangeable head Installation and Operating Instructions 9000-618-178/30 2014/07 Content Important information 1. About this document 4 1.1 Warnings and Symbols 4 1.2 Copyright notice
More informationE200 ORT - Optical Rotary Torque Transducer. Contents
E200 ORT - Optical Rotary Torque Transducer Contents Optical Rotary Torque Transducer [E200 ORT]: TSE2038R Rotary Torque Transducer Installation Guide: TS3001J Optical Rotary Torque Transducer [E200 ORT]
More informationSTANDARD TEST METHOD AND PERFORMANCE SPECIFICATION USED IN EVALUATING THE PERFORMANCE CHARACTERISTICS OF CHEST PROTECTORS FOR COMMOTIO CORDIS
STANDARD TEST METHOD AND PERFORMANCE SPECIFICATION USED IN EVALUATING THE PERFORMANCE CHARACTERISTICS OF CHEST PROTECTORS FOR COMMOTIO CORDIS NOCSAE DOC (ND) 200-17m17 Prepared By NATIONAL OPERATING COMMITTEE
More informationTesting Digital Hearing Aids
Testing Digital Hearing Aids with the FONIX 6500-CX Hearing Aid Analyzer Frye Electronics, Inc. Introduction The following is a quick guide for testing digital hearing aids using the FONIX 6500-CX. All
More informationSignals, systems, acoustics and the ear. Week 1. Laboratory session: Measuring thresholds
Signals, systems, acoustics and the ear Week 1 Laboratory session: Measuring thresholds What s the most commonly used piece of electronic equipment in the audiological clinic? The Audiometer And what is
More informationLUSI XPP Detector-Mover Engineering Specification
ENGINEERING SPECIFICATION DOCUMENT (ESD) Doc. No. SP-391-000-62 R0 LUSI SUB-SYSTEM XPP DIFFRACTOMETER LUSI XPP Detector-Mover Engineering Specification Prepared by: J B Langton Signature Date XPP System
More informationCORESTA RECOMMENDED METHOD N 22
CORESTA RECOMMENDED METHOD N 22 ROUTINE ANALYTICAL CIGARETTE-SMOKING MACHINE SPECIFICATIONS, DEFINITIONS AND STANDARD CONDITIONS (August 1991) 0. INTRODUCTION This CORESTA Recommended Method includes the
More information