Operating Instructions PROTAR evo. Always on the safe side.

Size: px
Start display at page:

Download "Operating Instructions PROTAR evo. Always on the safe side."

Transcription

1 Operating Instructions PROTAR evo. Always on the safe side.

2 Vertrieb/distribution: KaVo Dental GmbH Bismarckring 9 D-8800 Biberach Tel.: 0 7 / Fax: 0 7 / 88 Hersteller/manufacturer: Kaltenbach & Voigt GmbH Bismarckring 9 D-8800 Biberach

3 A User notes... A. Meaning of the pictograms... A. Important information... A. Safety measures... A. Purpose and applications... A. Observation of the movements of the mandible in the horizontal plane... A.6 System philosophy... A Scope of delivery Accessories...6 A. Scope of delivery...6 A Controls and functional elements... A Preparations for start-up operation... A.Support pin... A. Centric locks... A. PROTARevo with Splitcast (Factory adjustment)... A. Working with the Mounting Set Mat. No A. PROTARevo without Split-cast... A.. PROTARevo with magnetic fixing...6 A.6 PROTARevo with Splitcast...6 Assembly Instructions: Fitting magnetic fastenings to PROTAR articulators without split cast. Material number PS commonality material no A.6. Calibration A.6. Measuring...7 A Programming possibilities for KaVo PROTARevo articulators...8 A 6 Articulation of the model...9 A 6. Articulation of the upper model with the KaVo Face bow ARCUS...9 A 6. Articulation of the upper model with the help of the Transfer Stand...0 A 6. Articulation of the upper model with KaVo Facebow ARCUS light...0 A 6. Articulation of the upper model with face bows of other manufacturers... A 6. Programme data when using non KaVo face bows in the PROTAR Articulator... A 6.6 Average value method using the KaVo upper jaw model positioner Mat. No APFnt Method... A 6.7 Average value method using the KaVo Mounting and Setup Aid for the upper jaw... A 6.8 Average value method for the lower jaw model using the KaVo Plastering Gauge Mat. No A 6.8. Mounting of an edentulous lower jaw model... A 6.9 Articulation of the lower jaw model...7 A 7 Programming the articulator...8 A 7. Adjusting the condylar path inclination with protrusion recording block...8 A 7. Adjusting the Bennett angle with the left and right laterotrusion recording block...8 A 7. Setting the immediate Side Shift (ISS)...9 A 7. Adjusting the Shift-angle...0 A 7. Setting of a protrusion / distraction position... A 7.6 Setting the retrusion... A 7.7 Producing an individual incisal guidance... A 7.8 Programming the adjustable incisal plate... A 7.8. By use of a situation model... A 7.8. By use of programme data from ARCUSdigma... A 8 Installation of the shift angle insert in PROTARevo 7... A 9 Programming the articulator with data from ARCUSdigma...6 A 0 Setup aid for full dentures...7 A 0. Setup aid for lower jaw models according to the APFnt method (Mat. No )...7 A 0. D Setup aid for lower jaw models according to the APF method...8 A 0. D Setup template for upper jaw model (Mat. No )...0 A 0. D Setup aid for the upper jaw (Mat. No..00.9)... A 0. D Setup aid for the upper model for screw mounting (Mat. No..00.9)... A Milling table with transfer plate Split system... A Transport Box KaVo LOGICase... A Technical data... A Maintenance and adjustment...6 Guarantee conditions...7 PROTARevo...8 Spare parts PROTARevo...8 PROTARevo B...9 PROTARevo...9 PROTARevo PROTARevo PROTARevo lower section...

4 A User notes A. Meaning of the pictograms Situation which can lead to danger, damage to materials or operating faults if the information is ignored. Important information for operators and technicians. Automatic mode Automatic sequence Close, screw in, fasten, etc. Open, release, loosen + more, higher - less, lower Continuous operation Time, time sequence Disconnect mains plug A. Important information The operating instructions should be read by the user before putting the unit into operation for the first time, in order to avoid incorrect operation and damage. If further language versions are required, please request these from your responsible KaVo agent. Duplication and distribution of the Operating Instructions (OI) require prior consent from KaVo. All technical data, information and properties of the unit described in these OI instructions correspond to the situation on going to press. Modifications and improvements to the product on the basis of technical innovations are possible. This does not imply any right to upgrading of existing units. KaVo assumes no responsibility for damage arising through: external influences (poor quality of the media or poor installation) use of incorrect information improper use improperly performed repairs. The following are authorized to repair and service KaVo products: the engineers of the KaVo agents throughout the world the engineers of the KaVo dealers who have been specially trained by KaVo independent engineers specially trained by KaVo. In the event of modifications by third parties, the approvals become null and void. KaVo recommends using only original spare parts for operation and for repairs. A. Safety measures Safe operation and protection of the unit are ensured only through proper use in accordance with the Operating Instructions, using the tools approved for this purpose. The following should also be followed: the work safety regulations the accident prevention regulations. In accordance with these requirements, it is the duty of the user to use only flawless materials to observe the correct applications to protect the patient, and others, from exposure to injury to avoid contamination by the product. not to work not with damaged functional parts.

5 A. Purpose and applications The Gnathostomatic System is one of the most complex locomotor organs in the human body, largely due to its three dimensional spatial movements. In the event where a therapeutic, prosthetic or orthognathic treatment is required, a function-oriented therapy is essential. Segments of this kind of therapy, by necessity, have to be performed extraorally, i.e. functional diagnosis, treatment planning, surgical, therapeutic or prosthodontic appliances. A simulation device which can mimic the mandibular movements and can accept the parameters of the patient s condylar and anterior guidance accurately, in addition, will retain the program of the dynamics of the mandible and the condyles, is not only necessary in the dental practice, but also in the dental laboratory. An articulator and associated measuring devices are indispensable tools for recording and transferring existing anatomical conditions or manipulable variables, they form the basis for functionoriented therapy. A defect-free morphological condition between the temporomandibular joint, the neuromuscular system and the dentition, forms the basis for a healthy and well functioning gnathostomatic system. 6 7 FH In order to faithfully reproduce the movements of the mandible on an articulator, anatomical reference points and reference lines have to be identified on the patient, with regard to a system of coordinates. The visual connection between the subnasal point and the Tragus Medialis for instance, forms Camper s Plane of Occlusion (CP). On the other hand, the visual connection between the Porion 6 and the Infra- Orbital Point (IOP) forms the Frankfurt Horizontal Plane (FHP). The co-ordinates of these reference points and planes result in the Horizontal Condylar Inclination (HCI). Other terms in use: Protrusive Path - Mid-Sagittal Horizontal Inclination - Condylar Path Angle. Subnasal point Okklusions plane 7 Hinge axis

6 Shift PROTAR evo. A. Observation of the movements of the mandible in the horizontal plane Protrusion With protrusion, the mandible moves forward. There is ventral and caudal movement of the two condyles. The movement tracks of the maxillary tooth are shown on the mandibular tooth. Mediotrusion and laterotrusion In lateral occlusion, a differentiation is made between laterotrusion on the working side and mediotrusion on the non-working side. The connection between the beginning and end point of the condyle moved inwards on the mediotrusive path forms the Bennett angle with the protrusion trace on the non-working side. Bennett The condyle describes a laterotrusion on the working side. Deviations from the. laterotrusion are defined as shift angle. Bennett

7 A.6 System philosophy The articulator and face bow system from KaVo is designed so that work can be carried out using either the Frankfurt horizontal plane (FH) or Camper s plane (CP). The nasal support provides an average alignment of the face bow with respect to the two planes. The face bow can also be individually aligned to the required reference plane by using the reference pointer. Infra-orbital point Subnasal point In the articulator, the face bow is always inserted in the same position on the lateral reference pins and on the incisal pin (set to zero). The bite fork will, however, vary in its position depending on the patient s anatomy. 6 6 Support of the face bow 7 Incisal pin 7 In the PROTAR articulator, the models are almost parallel (deviations ± 0º) with the Camper s plane 9. Advantage for dental technology: the models mounted in an articulator have their occlusion plane q almost parallel to the Camper s plane 9 and thus also to the work surface. The plaster expansion is uniform. w e r 8 9 q 0 8 Infra-orbital point 0 Subnasal point w Tragus medialis e Porion r Hinge axis

8 0 0 0 PROTAR evo. A Scope of delivery Accessories A. Scope of delivery Articulator PROTAR evo Cast consisting of: Articulator upper section Mat. No Articulator lower section Mat. No or Articulator PROTAR evo with-split- Cast consisting of: Articulator-upper section Mat. No Articulator-lower section Mat. No or PROTAR evo Artikulator PROTAR evo with-out Split-Cast consisting of: Articulator-upper section Mat. No Articulator-lower section Mat. No or Articulator PROTAR evo with-split- Cast consisting of: Articulator-upper section Mat. No..00. Articulator-lower section Mat. No or PROTAR evo CE Articulator PROTAR evo with-out Split-Cast consisting of: Articulator-upper section Mat. No Articulator-lower section Mat. No or Articulator PROTAR evo B with-split- Cast consisting of: Articulator-upper section Mat. No..00. Articulator-lower section Mat. No PROTAR evo CE or 0 Articulator PROTAR evo B with-out Split-Cast consisting of: Articulator-upper section Mat. No..00. Articulator-lower section Mat. No PROTAR evo B 6

9 0, 0,0 6 0,, 0,0, PROTAR evo. Articulator PROTAR evo 7 with-split- Cast consisting of: Articulator-upper section Mat. No Articulator-lower section Mat. No or Articulator PROTAR evo 7 with-out Split-Cast consisting of: Articulator-upper section Mat. No Articulator-lower section Mat. No PROTAR evo 7 or Articulator PROTAR evo 9 with-split- Cast consisting of: Articulator-upper section Mat. No..00. Articulator-lower section Mat. No or Articulator PROTAR evo 9 with-out Split-Cast consisting of: Articulator-upper section Mat.-No..00. Articulator-lower section Mat. No PROTAR evo 9 Operating Instructions PROTAR evo Mat. No

10 A. Optional accessories Available on Incisal pointer Mat. No Incisal guidance 0 Mat. No Incisal guidance 0 Mat. No Incisal guidance 0 Mat. No Incisal guidance 0 Mat. No Incisal guidance 0 Mat. No Split-cast-built-in set Mat.-No (without drawing) # Transfer stand Mat. No. 0.6 Orbital plane guide for non-kavo face bows Mat.-No. 0.6 b face bow holder c Adapter referenz pin Jigs for average value articulator mounting Mat. No Ì Template holder Mat. No \ Short template Mat. No Long template Mat. No Mounting/Setting-up aid Upper complete prosthesis Mat. No for PROTARevo with screw Clamp for non-kavo articulator Mat. No Mounting/Setting-up aid Upper complete prosthesis Mat. No for PROTARevo with control base q Upper-model positioner Mat. No w Occlusion angle indicator Mat. No e Plaster mounting sleeve Mat. No.0.6.,0 mm Mat. No.0.6.,0 mm Mat. No.0.6.,6 mm r Milling table with transfer plate Split system Mat. No t Mounting Set Mat. No z Plaster mounting disc Mat. No u Video ARCUS /PROTAR Mat. No i Denar adapter Mat. No o Panadent indicator Mat. No p Bitefork holder Mat. No

11 PROTAR evo. Available on request: p Support pin E Support pin P Support pin T Mat.-Nr Mat.-Nr Mat.-Nr p a s a Adjustable incisal plate Mat. No s Holder Mat. No E d Bitefork holder Mat. No f PDR-Insert (pair) Mat. No P T d f L R 0 g Shift angle inserts (pair) Mat. No h Carrying case Mat. No j Fixing screws for mounting plates ( pieces) Mat. No g h j only for PROTARevo k Calibration gauge Mat. No ö l Magnetic fixture Mat. No ö Mounting plates for PS (pack of 0) Mat. No k l y Synchronization PS Mat. No y Transport box / Work trays x LOCIcase (pack of 0.) Mat. No..00. LOCIcase (pack of 0.) Mat. No c Box for registrations Mat. No x c v v Round canister for small parts Mat. No b Foam sponge for securing of models Mat. No b 9

12 Consumable materials Mounting plates pack of 0 Mat. No Retention adapters pack of 0. Mat. No Retention adapters pack of 0. Mat. No Mounting plates (not for Split-cast) pack of 0 Mat. No Inserts for mounting plate pack of 0. Mat. No Plaster mounting disc pack of 0. Mat. No Mounting plates for PS (pack of 0 ) Mat. No Closure caps Mat. No Spare parts: 8 Upper section support pin Mat. No Shift angle inserts Mat. No Mould release screw Mat. No Magnet Mat. No q Magnet wrench Mat. No. 0.. w Elastic bands forprotar pack of 0 Mat. No e Adhesive for adjustments Mat. No q w e Härter Harz 0

13 A Controls and functional elements Articulator upper section PROTARevo ö Support feet Hinge box, right p Centric lock, right Centric lock, left 6 Control base 7 Articulator lower section 8 Incisal tray, 0 9 Incisal disc, flat 0 Support pin q Mounting plate, bottom w Mounting plate, top e Fixing Bennett angle and lateral movement (ISS), right r ISS setting, right t Hinge axis z Reference pin u ISS setting, left i Fixing Bennett angle and lateral movement (ISS), left o Hinge box insert, left p Hinge box, left a Spring element, left PROTARevo h p w PROTARevo w p PROTARevo B o a j h CEFH f d a s Fixing shift angle, left d Fixing of hinge box, left f Fixing of hinge box, right g Fixing shift angle, right h Spring element, right j Hinge box insert, right k Ball joints l Magnet retention system 0 w p o q CEFH f d a k j h t z ö Tommy screw (optional) l 7

14 0,,0 0,,0 0 0 PROTAR evo. Articulator upper section PROTARevo 7 Support feet Hinge box, right Centric lock, right e r j g Centric lock, left 6 Control base 7 Articulator lower section 8 Incisal tray, 0 9 Incisal disc, flat w i u p o D CEFH s f d a h 0 Support pin q Mounting plate, bottom PROTARevo 9 w Mounting plate, top e Fixing Bennett angle and lateral movement (ISS), right r ISS setting, right t Hinge axis z Reference pin u ISS setting, left i Fixing Bennett angle and lateral movement (ISS), left w i u p o D CEFH s f d a e r j h g o Hinge box insert, left p Hinge box, left a Spring element, left s Fixing shift angle, left d Fixing of hinge box, left 0 k f Fixing of hinge box, right g Fixing shift angle, right h Spring element, right q t z j Hinge box insert, right k Ball joints l Magnet retention system ö Tommy screw (optional) l 7

15 A Preparations for start-up operation A.Support pin Insert support pin 6 into top or bottom part of articulator and screw in firmly CE Fit flat incisal plate with 0 incisal tray in the top or lower section. 0-0 trays can also be used instead of the 0 tray. 6 A. Centric locks open Position 0 7 In position 0 the centric lock is closed. The articulator upper section can only be rotated in the closed position 7 0 Position 9 When the centric locks are in the middle Position, the articulator is freely movable so that the desired articulator movements can be carried out. The spring elements 8 press the condyles against the joint surfaces 0 of the hinge boxes to prevent them from lifting off. 8 In its Position, the articulator can be handled like a non-arcon articulator. This will prevent the upper and lower sections of the articulator from coming apart

16 Position = open In this position, the upper section can be removed. 0 After positioning the articulator upper sections and closing the two centric locks, the articulator is now complete. The centric locks can only be closed when the articulator upper section is firmly located into the condylarball. The left centric lock must always be closed first. R L R = right L = left

17 A. PROTARevo with Splitcast (Factory adjustment) If the articulator is factory-equipped with the KaVo Splitcast, the magnetically-held control plate serves to accept the model. The retention adapter is used for retention of After completing the work, the model is pressed out of the control plate by use of the star-grip screw. Finally, clean the control plate. A. Working with the Mounting Set Mat. No The mounting set enables the production of accurately fitting plaster plates for the KaVo Split- Cast. Practical hints function Snap the mounting disc into the mounting set 6. As a rule, the mounting set does not have to be insulated. Remove the plaster plate after 6 hours, at the latest. After each use, immediately clean the mounting set thoroughly under running water. If necessary, use KaVo Separating Material (Order No. 0.6.). Blow off superfluous separating material. 6 7 Never use plaster solvents to clean the mounting set. Mat.- No. see A. A. PROTARevo without Split-cast 8 9 If the Artikulator is factory-installed equipped without Split-cast, then the mounting plates 9 (0.6.87) are fixed with the help of a tommy screw

18 A.. PROTARevo with magnetic fixing By use of the magnetic fixing , a magnet can be located in the PROTA- Revo in place of the capstan-head screw.together with the PS mounting plates a fast change of model is possible. This method of fixing the model does not allow synchronization. A.6 PROTARevo with Splitcast (Adjustment in the laboratory) PROTARevo articulators, which are not factory-equipped with a Split Cast, can be synchronized with the PS mounting plates in the laboratory. Required accessories: Mounting plate PS Mat. No Calibration gauge Mat. No Assembly Instructions: Fitting magnetic fastenings to PRO- TAR articulators without split cast. Material number It is possible to fit magnetic fastenings to PROTAR articulators without split cast. The diagram shows the individual steps to be performed on the articulator base: Remove the model mounting plate 7. Unscrew and remove the model mounting plate positionig pins and tommy screw 8 from the articulator. Insert magnet 6. PS commonality material no Upper part of articulator Remove the model mounting plate. Unscrew and remove the model mounting plate positionig pins and tommy screw from the articulator. Articulator base Remove the model mounting plate 7. Unscrew and remove the model mounting plate positionig pins and tommy screw 8 from the articulator. Fasten the magnet 6 securely using the screws

19 A.6. Calibration Remove foam washer ( ) from holder and glue centrally on calibration plate. Insert measuring and calibration gauge 6 in the articulator lower part. The magnet holds the gauge. Place calibration plate on the gauge 6. Adjust articulator support pin 7 to 0 (or zero with ratchet pin). Remove magnet, if this is mounted in articulator upper part. 7 Spread the provided adhesive over calibration plate outside the washer and carefully close the articulator. (Adhesive is sufficient for approx. calibrations) 6 A.6. Measuring The measuring/calibration gauge is designed to check the calibration at any time in the laboratory. To this end, the gauge is separated into two parts with the help of the two centre screws. Now the calibration can be checked by using occlusal paper. 7

20 A Programming possibilities for KaVo PROTARevo articulators PROTAR PROTAR PROTAR PROTAR B PROTAR 7 PROTAR 9 Saggittal condylar path Fixed Fixed Adjustable Adjustable Adjustable Adjustable 0 zur CE 0 zur CE -0 bis 90 (FH) -0 bis 90 (FH) -0 bis 90 (FH) -0 bis 90 (FH) zur FH zur FH - bis 7 (CE) - bis 7 (CE) - bis 7 (CE) - bis 7 (CE) Horizontal condylar path - (Bennet) Fix Fixed Fixed Fixed Adjustable Adjustable Adjustable Horizontal condylar path (ISS) 0 mm 0 mm 0 mm 0 mm 0 -, mm 0 -, mm Horizontal condylar path - Shift angle Optional bis +0 0 with 0.6. Adjustable Adjustable Protrusion 0 -, mm 0-6 mm Retrusion 0 - mm 0 - mm Distraktion 0 -, mm 0-6 mm 8

21 A 6 Articulation of the model A 6. Articulation of the upper model with the KaVo Face bow ARCUS Release clamping lever and pull face bow The support pin must already be located in the articulator lower section and set to the zero position. (Remove the incisal plate 6 and close the centric locks, at first the left, finally the right of the upper section). Affix the ear-pieces of the face bow to the orientation pins on the articulator lower section, slide the face bow together again then lock the clamping The face bow is placed on the support pin. Position the upper dentition in the impressions 7 on the bite fork. Mix the plaster to a creamy consistency, and place on the model of the upper jaw (Close the opening in the control plate with the retention adapter Mat. No ) Spread the plaster over the control plate in the upper section. Close the upper section, using no pressure. 7 6 After the plaster has hardened, remove the face bow together with the bite fork from the articulator. Release clamping lever, and take the facebow out of the articulator. 9

22 A 6. Articulation of the upper model with the help of the Transfer Stand If articulation is to be carried out in the dental laboratory, it is only necessary to send the bitefork with holder. Remove the support pin and incisal plate from the articulator. Locate Transfer Stand in the lower section of the articulator. Insert bite fork with bitefork holder into the transfer stand. A 6. Articulation of the upper model with KaVo Facebow ARCUS light Attach face bow ARCUS light with its earpieces to the orientation pins on PROTARevo. The provided support 8 is screwed into the lower end of the rod 7, for the bitefork holder 6. 6 Place facebow ARCUS light with its support 8 on the worktop. Place the articulator upper section on the facebow

23 A 6. Articulation of the upper model with face bows of other manufacturers The following accessories are required: Non-KaVo face bow reference kit Mat. No Consisting of: Reference plane (collar + screw) Face bow holder Adapter reference pin This accessory enables face bow systems of other manufacturers to be mounted in the PROTARevo Articulator. For systems with a free-moving pointer, a reference plane is required for the articulator upper section. (Illustration - Dentatus) The Dentatus face bow, with its infraorbital indicator, is swivelled until it contacts with the reference plane. Mounting of face bows with Swivelling pointer or glabella support (eg. SAM, Whip Mix) - remove incisal plate and support pin from the articulator. Turn the knurled screw of the transfer stand almost completely out, and push the transfer stand in its second possible position as far as the stop into the articulator lower section, then tighten the knurled screw. Mount the face bow holder onto the transfer stand. Locate the face bow holder with the help of the scale division and fix into position with the knurled screw. Denar Adapter Order No Using the Denar Adapter enables articulation with the Denar Bitefork.

24 7 6 0 PROTAR evo. A 6. Programme data when using non KaVo face bows in the PROTAR Articulator The following accessories are required: Transfer stand Mat. No Non-KaVo reference kit Mat. No consisting of: Reference plane (collar + screw) Face bow holder Adapter reference pin Manufacturer mounting with nasal support reference pointer accessory required possibility scale value for infra-orbital point scale value Girrbach Rotofix yes 9 66 Transfer stand, Reference plane + face bow holder Girbach yes Transfer stand Referenz Reference plane + face bow holder Dentatus yes - - Reference plane Hanau yes - - No accessories required Earpiece front cross rod 70 mm Face bow over worktop SAM yes 8 - Transfer stand Face bow holder Panadent yes not Transfer stand possible Reference plane and face bow holder and extra pointer (0.6.7) Hanau 6- yes - 9 Transfer stand Twirl-Bow Reference plane + face bow holder Gerber conditional - - No accessories required Denar yes - - Adapter Mat. No Whip-Mix yes 6 - Transfer stand Reference plane + face bow holder Adapter reference pin Quick yes 6 top - Transfer stand 9 middle Reference plane + face bow holder bottom Springbow yes orientate on with bitefork support Hanau reference plane Hager und Werken yes 6 Transfer stand Reference plane + face bow holder Ivoclar yes 9 Transfer stand Reference plane + face bow holder further manufacturers on request

25 A 6.6 Average value method using the KaVo upper jaw model positioner Mat. No APFnt Method The medium-value model positioner for an edentulous upper jaw model makes articulation possible, if no face bow is available. The edentulous flaps and the lowest points behind the two tubercles serve as reference points. Fixiing screw Adjustment mark if KaVo Split- Cast is not installed. Adjustment mark when KaVo Split- Cast is installed. Reference points

26 A 6.7 Average value method using the KaVo Mounting and Setup Aid for the upper jaw The Mounting-Setup aid Mat. No (without Split- Cast- mounting) Mat. No (with Split- Castmounting) enables medium-value articulation of an edentulous upper jaw model, if no face bow is available. The setup aids are aligned parallel to Camper s Plane. The mesial alignment is achieved by use of the papilla screw. According to the setup method, the papilla screw is withdrawn to the appropriate length, the model with its papilla placed on the screw, and the cradle pushed in so far until this comes to rest at the lowest point behihd the two tubercles. By use of the adjustment screw, the mounting and setup aid is uniquely aligned to the occlusal plane 6 of the respective articulator. 6 By using the clamp.00.97, the mounting and setup aid.00. can also be fixed in the Denar, Hanau and Stratos articulators.

27 A 6.8 Average value method for the lower jaw model using the KaVo Plastering Gauge Mat. No (APF Method) The plastering gauge makes it possible for partial or fully edentulous lower jaw models to be articulated in the PROTAR articulator. If the KaVo articulator is equipped with the Split-Cast, the plastering gauge must be fixed in Position (loosen screw ) If no Split-Cast is mounted, the gauge must be fixed in Position. A 6.8. Mounting of an edentulous lower jaw model Draw a circle around the retro-molar protuberance of the lower jaw model. Mark a centre line and divide into three parts. The occlusal plane runs to the upper marking.

28 Adjust the symphysis fork 9 to the height of the lower wax rim 8. Upper wax rim Locking screw Average value plastering gauge 6 Retro-molar protuberance 7 Sliding foot to retro-molar protuberance q Lower wax rim 9 Symphysis fork 0 Occlusal plane q Camper s plane After releasing the locking screw w, move the sliding part to the desired position and tighten the locking screw. Fix the plastering gauge to the model by using a rubber band e. w 9 e Finally, articulate the lower jaw model in the articulator. 6

29 A 6.9 Articulation of the lower jaw model Turn the articulator upside down. (centric locks remain closed). Fold out the articulator. Set the lower jaw model on the upper jaw model, with no rocking movement. When working without centric registration, the support pin is set at zero. Close the opening in the control plate with a retention adapter Mat. No Then apply plaster of a creamy consistency to the lower jaw model, and to the control plate of the articulator lower section. Using no pressure, now close the articulator. After the plaster has hardened, remove the centric registration and return support pin to the zero position. The upper and lower jaws are now articulated in the correct relationship. 7

30 A 7 Programming the articulator A 7. Adjusting the condylar path inclination with protrusion recording block (for PROTAR, B, 7, 9) Open the two centric locks and place the protrusion recording block between the dentition of the plaster models. This pushes the lower part of the articulator forwards in relation to the top part. The ball joints 6 of the articulator now no longer touch the condyle path. Release the clamps of the hinge boxes and bring the respective hinge boxes into contact with the ball joints 6. Apply clamps of the hinge boxes. 7 A 7. Adjusting the Bennett angle with the left and right laterotrusion recording block (for PROTARevo B, 7, 9) Release clamps and set the max. Bennett angle. Setting the left Bennett angle Place the right laterotrusion recording block between the dentition of teeth of the upper and lower jaws. 6 Turn the left hinge box insert 7 until the ball joint 6 and insert 7 touch and then secure with clamp. Setting the right Bennett angle Place the left laterotrusion recording block between the dentition of teeth of the upper and lower jaws. Turn the right hinge box insert 8 until the ball joint 6 and insert 7 touch and then secure with clamp. 8 Close the centric locks and place the articulator in its working position. 8

31 A 7. Setting the immediate Side Shift (ISS) (für PROTAR B, 7, 9) The immediate side shift (ISS) of the mediotrusion condyle can be preselected from 0 to. mm (in 0. mm steps). The fixing screw of the Bennett angle guides must be slackened by about / of a turn to make the adjustment. Set the adjustment to the value required on the adjustment mark of the immediate side shift (ISS). Retighten the fixing screw. The Bennett angle selected is retained. 9

32 A 7. Adjusting the Shift-angle If PROTAR 7 is equipped with the shift angle inserts (0.6.), movements on the working side (Laterotrusion side) can be exactly Slacken knurled screw so that the shiftangle insert can be adjusted by turning the pin. With the left lateral registration, the right Bennet angle and the left shift angle can be adjusted simultaneously. With the right lateral registration, the left Bennet angle and the right shift angle can be adjusted To adjust, turn the shift angle insert so far until it makes contact with the joint ball. 0

33 A 7. Setting of a protrusion / distraction position PROTARevo 9 The PROTARevo 9 is constructed in the same way as the PROTARevo 7. Supplementary the PROTARevo 9 has a P/D/R-insert. Mat. No right / left Defined Protrusion setting Defined Distraction setting Defined Retrusion setting The PROTARevo 7 can be retrofitted with P/D/R-insert. Setting a guided protrusion from 0 to mm in 0, mm steps from to 6 mm in 0, mm steps These settings are specifically guided and reproducible. The upper section stops in each protrusion setting. Examples of uses: Protrusion guides Grinding in the occlusion Setting a guided distraction from 0 to mm in 0, mm steps from to 6 mm in 0, mm steps from the centric position These settings are specifically guided and reproducible. The upper section stops in each distraction setting. The support pin can be readjusted accordingly. Example of use: Bite plate guides.

34 A 7.6 Setting the retrusion To produce retrusive free spaces when waxing, a retrusive movement is possible in PROTARevo 7/9. This reduces grinding-in work on the part of the dentist. Retrusive free spaces have already been provided in the modelling. Zero position of the When the lateral movement (ISS) is set to. mm, the retrusive movement can be increased to.0 mm (in step of 0, mm). In this case, no exactly centric position is possible with centric locks closed!

35 A 7.7 Producing an individual incisal guidance The user can shape an individual incisal guidance from the flat PROTAR incisal plate. Set the articulator centric lock to position and fold open the articulator towards the rear. Apply a release agent (petroleum jelly) to the incisal plate and the tip of the support pin. Fill the incisal plate with a doughy, stirred autopolymer so that it comes flush with the edge. By using models before the preparation, the front incisal guidance can be transferred to the still doughy autopolymer by movements in the articulator with the support pin. Release the individual tray from the incisal plate by levering it out with a suitable instrument in the opening in the incisal plate. The individual incisal guidance can be reinserted, since the retention slot allows the correct position to be found accurately.

36 A 7.8 Programming the adjustable incisal plate A 7.8. By use of a situation model Before cutting the teeth, a situation model from the patient is produced. The adjustable incisal plate is then programmed with this situation model. For correct installation of the incisal plate, the middle guidance is set to a value of approx. 70. R The incisal plate is then moved until contact with the ball of the incisal plate is reached, and then is fixed with the locking screw. L M Move the lower jaw in the articulator to the left and set the left guidance,. Then move the lower jaw to the right and set the right guidance. The middle guidance can be set by moving the model along the anterior teeth. Thus, the adjustable incisal plate records the tooth guidance. A 7.8. By use of programme data from ARCUSdigma The ARCUSdigma directly provides the programme data for the incisal plate. Set the values as described. (R) (M) (L) 60,0 6,6 7,0

37 A 8 Installation of the shift angle insert in PROTARevo 7 First the existing protrusion/retrusion cylinder has to be removed. This is achieved with the help of the provided hexagonal-slot wrench by using some some pressure to push out the locking pin from the drive wheel.. Remove protrusion/retrusion cylinder. Remove drive wheel. Remove black plastic stopping device Installing the shift angle insert 6. 6 The shift angle insert is installed as follows: - Push screw 7 in the slot. - Push the shift angle insert 8 from outside into the articulator box. - Tighten screw

38 A 9 Programming the articulator with data from ARCUSdigma (Mat. No ) PROTAR 7 together with shift angle insert (Order No. 0.6.) and the adjustable incisal plate (Order No ) can exactly reproduce all calculated settings. 6

39 A 0 Setup aid for full dentures A 0. Setup aid for lower jaw models according to the APFnt method (Mat. No ) Attach the occlusion inclination indicator to the centering axis of the articulator. Tighten screw. Turn the articulator upside down. Lay template on the model. In the mesial area, place the front insert on the two first anterior teeth. 6 In the dorsal area, position the rear crossrod 6 behind the two tubercles. Tighten screw, then tighten screw 7. If necessary, re-adjust screw again. 7 7

40 A 0. D Setup aid for lower jaw models according to the APF method Receptacle Template holder Long template Mat. No Short template Mat. No Positioning screw This template system can be applied generally no matter which aspects have governed mounting of the model in the articulator (face bow or jig for averagevalue articulator). With this template system, the user is provided with a flat surface providing the reference to the occlusal plane, and a convex surface, which takes into account the compensation curves in both the saggittal and transversal directions with respect to the static position of the mandible. The template can be universally adjusted with the aid of the template holder and the receptacle. The template can be aligned in every case whether with face bow, articulator jig or rubber band. By pressing the receptacle together, the complete unit is fixed between the balljoints of the articulator. 8

41 For alignment, the template is placed on the wax rim. To achieve this, the wax rim must be occlusally modified so that the template is aligned in the areas of the incisors and the lower molars. The flat surface of the template can be used, for example, for the Gerber method. The position of the template is determined by the positioning screw, which is fixed to the model through the template. The wax rim can now be somewhat retracted for setting up. A small drop of sticky wax will hold the positioning screw. The lower jaw can now be set up against the template. After removing the template holder, the articulator is once again complete. 9

42 A 0. D Setup template for upper jaw model (Mat. No ) This flat setup aid for the edentulous upper jaw model is aligned by the upper wax rim. To achieve this, the setup aid is held against the upper wax rim by a rubber band. The setup aid is then individually fixed in the lower section of the articulator by a small amount of plaster. 0

43 A 0. D Setup aid for the upper jaw (Mat. No..00.9) This accessory is both a plastering and a setup aid for the edentulous upper jaw. After retracting the papilla screw and pushing back the setdown slider, settting up of the upper jaw model can now begin. A 0. D Setup aid for the upper model for screw mounting (Mat. No..00.9)

44 A Milling table with transfer plate Split system For dental laboratory work required milling operations, it is often necessary to transfer the model alternately between articulator and milling machine. Magnet control bases lever The magnetic force provides secure holding of the work also during milling operations. The edge-to-edge fit of the split cast system based on the articulator mounting plates guarantees precise holding of the work. The model is set just once for the milling work and can then be rotated as often as required without the need for further adjustment.

45 Occlusal features can be constructed in the articulator. The necessary milling work can be carried out at any time. By accurate fit of the transfer between articulator and milling machine, all work stages can be continuously controlled.

46 A Transport Box KaVo LOGICase KaVo LOGICase the economic stackable transport box between the dental practice and laboratory. KaVo LOGICase is a transport box and work tray in one unit. Foam sponge for holding the models (0 pieces ) For the first application at ERGOspace the side latches are opened. Round canister for small parts (0 pieces ) Field for barcode Field for patient s name 6 0 boxes (0 half-trays.00.) 0 boxes (00 half-trays.000.9) 7 Square container for registrations (0 pieces ) Labor Mustermann Hygiene: LOGIcase can be disinfected with conventional materials. Following contents are possible: - models - or impression trays - KaVo ARCUS bite fork holder - containers for registrations - canisters for small parts 7 Special holder 8 for KaVo laboratory furniture programme. 6 Universal insert for all further furniture programmes

47 A Technical data PROTAR evo,, 7 and 9 articulators Lower section Intercondylar distance = fixed 0 mm 0 Support pin Adjustment range from + 0 mm to - 0 mm with locking facility Incisal table flat Incisal tray 0 (Accessories 0, 0, 0,0 ) Height 0 mm with mounting plate 08 mm + with split cast 97 mm Balkwill angle 0 Camper s plane (CE) parallel to the table plane Bennett angle, curved (after mm excursion) 0 ( 0, 0, 0, 0 ) Weight (with Split-Cast) Articulator lower section Articulator upper section PROTAR Articulator upper section PROTAR /7/9 90 g 60 g 0 g Technical modifications reserved CE

48 A Maintenance and adjustment Before starting up operation, spray the articulator with commercially available release agents (silicone sprays) - do not apply grease. Apply a light film of oil to ball joints 8, magnet retention system 9 or mounting plate thread as required. If the clamping levers for the HCI no longer clamp properly, they can be readjusted. Tool: Hexagon-slot wrench. mm 6 Screwdriver. mm For re-adjusting the centric locks and. Hexagon-slot wrench outer mm Hexagon-slot wrench inner mm Split-cast mounting in PROTARevo //7/9. (It is advisable to check every six months with measuring and adjusting gauge 0.6..) Unscrew magnet retention system 9 with magnet key q. For reasons of accuracy, the split-cast is aligned onto flanks e. The mounting plate must come flush with the flanks e. The gap w between the split cast r and the mounting plate must be parallel. On completion of the work, press off the model using the star grip screw u of the mounting plate t - z. Then clean mounting plates t - z. For better lubrication grease the Hinge i with Articulator Lubricating Paste REF

49 Guarantee conditions For the product cited in the transfer protocol, KaVo warrantees the end customer that the product will function properly, have no material or manufacturing flaws for months from the date of purchase under the following conditions: In the case of valid complaints due to defects or a short delivery, KaVo will make good its warranty by replacing the product free of cost or repairing it according to your wishes. All other claims of any kind are excluded, especially claims for damages. In case of delayed performance, gross negligence or criminal intent, this shall apply only if there are no compelling legal regulations to the contrary. KaVo is not liable for defects and their consequences that arise from natural wear, improper cleaning or servicing, the non-observance of instructions for use, servicing or connection, scale formation or corrosion, impurities in the air and water supply, or chemical or electrical influences that are unusual or impermissible according to the manufacturer's specifications. The warranty does not generally extend to lamps, glassware, rubber parts and the colour fastness of plastic parts. No liability is assumed when defects or their consequences can arise from manipulations or changes to the product by the customer or a third party. Claims from this warranty can only be asserted when the transfer protocol (copy) belonging to the product has been sent to KaVo, and the original can be presented by the operator or user. 7

50 Spare parts PROTARevo Mat.-Nr. No without ohne Split-Cast PS (0x) x Verk.-Nr. PROTARevo Mat.-Nr mit Split-Cast Mat.-Nr ohne Split-Cast 06/ PROTARevo Mat. Mat.-Nr. No with Split-Cast mit Split-Cast No without Split-Cast Mat.-Nr. ohne Splitcast x x (0x) x PS x 8

51 PROTARevo Mat. No..00. with Split-Cast Mat.-Nr..00. mit Splitcast Mat. No without Split-Cast Mat.-Nr ohne Splitcast x (0x) CEFH x PS Verk.-Nr PROTARevo x B Mat.-Nr mit Split-Cast Mat.-Nr ohne Split-Cast x 06/ PROTARevo B Mat. No..00. with Split-Cast Mat.-Nr..00. mit Splitcast Mat. No..00. without Split-Cast Mat.-Nr..00. ohne Splitcast x (0x) x CEFH x 9

52 0,,0 0 6 PROTAR evo. PROTARevo 7 Mat. No. Mat.-Nr with Split-Cast mit Splitcast Mat.-Nr. No ohne without Splitcast Split-Cast (0x) x x Verk.-Nr. PROTARevo Mat.-Nr..00. mit Split-Cast Mat.-Nr..00. ohne Split-Cast D CEFH (L) (R) (R) (L) x PS x 06/ R PROTARevo 9 Mat.-Nr. No..00. with mit Split-Cast Splitcast Mat.-Nr. No..00. without ohne Split-Cast Splitcast (L) (R) (0x) x (R) (L) x x

53 PROTARevo lower section Mat.-Nr. No with mit Split-Cast Splitcast Mat. Mat.-Nr. No without ohne Split-Cast Splitcast x (8xx0,) (8xx0,8) (8xx0,0) x PS x x

54 Fk 7/07 en 09.0 KaVo Dental GmbH. D-8800 Biberach/Riss Telefon Fax Internet:

3000 Series Articulator System

3000 Series Articulator System 3000 Series Articulator System Models 3040 and 3140 Instruction Manual Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com

More information

We have simplified the. for you! Just a few steps to the articulator system of your choice! choose the perfect articulator for you!

We have simplified the. for you! Just a few steps to the articulator system of your choice! choose the perfect articulator for you! A rticu l ato r s a n d Acc es s o r i es 13 SAM K I T SYS T EM All SAM articulators will be delivered with the same standard equipment from April 2007 on, that is curvature 1 white (with shallow curvature)

More information

KaVo PROTAR evo. Exciting design and function.

KaVo PROTAR evo. Exciting design and function. KaVo PROTAR evo Exciting design and function. KaVo PROTAR evo. Design and function in a new dimension. Show the precision. Effective direct performance. Present high quality. Alongside perfect precision

More information

Exciting design and function.

Exciting design and function. PROTARevo_en_1.002.4402 01.08.2007 13:48 Uhr Seite 1 KaVo PROTAR evo Exciting design and function. PROTARevo_en_1.002.4402 01.08.2007 13:48 Uhr Seite 2 KaVo PROTAR evo. Design and function in a new dimension.

More information

KaVo ARCUS digma the new generation. What human senses can t capture.

KaVo ARCUS digma the new generation. What human senses can t capture. What human senses can t capture. What human senses can t capture. Digma can. Integration in the treatment procedure. Self-sufficient, when Digma is to be located in differing positions in the practice.

More information

The Hanau Modular Articulator System 194 Fixed 11 cm width, adjustable Radial-Shift Guidances. Illustrated Instruction Manual

The Hanau Modular Articulator System 194 Fixed 11 cm width, adjustable Radial-Shift Guidances. Illustrated Instruction Manual The Hanau Modular Articulator System 194 Fixed 11 cm width, adjustable Radial-Shift Guidances Illustrated Instruction Manual A Study Case for Occlusal Analysis This instruction manual illustrates the

More information

The Hanau Modular Articulator System 190 Fixed 11 cm width, adjustable Bennett Angle and/or Adjustable Protrusion. Illustrated Instruction Manual

The Hanau Modular Articulator System 190 Fixed 11 cm width, adjustable Bennett Angle and/or Adjustable Protrusion. Illustrated Instruction Manual The Hanau Modular Articulator System 190 Fixed 11 cm width, adjustable Bennett Angle and/or Adjustable Protrusion Illustrated Instruction Manual A Study Case for Occlusal Analysis This instruction manual

More information

Prosthodontics. Dental articulator. 1-Allow most of the prosthetic work to be done in the absence of the patient.

Prosthodontics. Dental articulator. 1-Allow most of the prosthetic work to be done in the absence of the patient. Prosthodontics Dental articulator Definition: It is a mechanical instrument that represents the TMJ and jaw members to which the maxillary and mandibular casts are attached to simulate some or all mandibular

More information

Face-Bow Instructions

Face-Bow Instructions M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 The following procedure is followed when Panadent Bite-Tab compound discs are used

More information

Unique Dental Supply. Catalog We Bring World Quality Products to Enhance your Business QUALITY PRODUCTS SINCE 1974

Unique Dental Supply. Catalog We Bring World Quality Products to Enhance your Business QUALITY PRODUCTS SINCE 1974 Panadent Articulating System FINAL:UDS-NL-2013 14-09-22 2:04 PM Page 3 UDS Unique Dental Supply We Bring World Quality Products to Enhance your Business R QUALITY PRODUCTS SINCE 1974 Catalog 2014 Panadent

More information

Symposium on Occlusal Articulation. Mandibular Movement Recordings and Articulator Adjustments Simplified. Harry C. Lundeen, D.D.S.

Symposium on Occlusal Articulation. Mandibular Movement Recordings and Articulator Adjustments Simplified. Harry C. Lundeen, D.D.S. Symposium on Occlusal Articulation Mandibular Movement Recordings and Articulator Adjustments Simplified Harry C. Lundeen, D.D.S. Judging from the volume of writing that has appeared in the dental literature

More information

Jaw relation (Maxillomandibular relationship): any one of the infinite

Jaw relation (Maxillomandibular relationship): any one of the infinite Maxillo-mandibular Relationship Jaw relation (Maxillomandibular relationship): any one of the infinite spatial relationships of the mandible to the maxilla. Jaw relation record: It is a registration of

More information

Lab Procedure Prior to Try-in

Lab Procedure Prior to Try-in Lab Procedure Prior to Try-in It is the procedure of attaching the maxillary and mandibular casts to the articulator in their recorded jaw relation. It is also called articulation. The maxillary cast is

More information

529-A Treatment and Management of the Edentulous Patient. Upon completion of this course the student should be able to:

529-A Treatment and Management of the Edentulous Patient. Upon completion of this course the student should be able to: Course & Title: Session & Topic: 529-A Treatment and Management of the Edentulous Patient Jaw Relations General Goal: To understand the principles of orientational, horizontal and vertical jaw relations

More information

Articulator Instructions

Articulator Instructions M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 Raise and lock incisal pin and support pin (arrow) at least 5mm above incisal table.

More information

Bite-Tab Compound Disks 180/box Накусочные таблетки для фиксации прикусной вилки лицевой дуги. Features & Benefits. Bite-Tray регистраты 50/Bag

Bite-Tab Compound Disks 180/box Накусочные таблетки для фиксации прикусной вилки лицевой дуги. Features & Benefits. Bite-Tray регистраты 50/Bag Product Catalog Bite-Tab Compound Disks 180/box Накусочные таблетки для фиксации прикусной вилки лицевой дуги. Constructed from red impression compound deposited on self adhesive strips. Can be used with

More information

The Effect of the Central Bearing Plate Form on the Fischer Angle

The Effect of the Central Bearing Plate Form on the Fischer Angle The Effect of the Central Bearing Plate Form on the Fischer Angle Yasuhiro Kamimura, D.D.S. Kobe City, Japan INTRODUCTION The Fischer angle, which has been defined as "the angle between the inclinations

More information

Analog Selector Instructions

Analog Selector Instructions M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 Analog Selector Instructions Raise and lock incisal pin (arrow) at least 5mm above

More information

Multipower. User Guide E S S E N T I A L S T R E N G T H

Multipower. User Guide E S S E N T I A L S T R E N G T H E L E M E N T E S S E N T I A L S T R E N G T H User Guide The identification plate of and manufacturer, affixed to the frame behind the barbell rack, gives the following details: A B C D E Name and address

More information

There is one thing different. Everything.

There is one thing different. Everything. There is one thing different. Everything. THE MODEL MAKER THE SET-UP MODEL MAKER THE OCCLUSAL PLANE REFERENCE THE SURGICAL MODEL ACCURACY DEVICE Precise - Easy - Clean - Economical - Multi Purpose - Essential

More information

Kois Dento-Facial Analyzer System Instructions

Kois Dento-Facial Analyzer System Instructions These instructions apply to the following items: M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 Kois Dento-Facial Analyzer System

More information

Horizontal Jaw Relation

Horizontal Jaw Relation Horizontal Jaw Relation Horizontal Jaw Relation It is the relationship of the mandible to the maxilla in a horizontal plane. It can also be described as the relationship of the mandible to the maxilla

More information

DENAR TRACK II SYSTEM instruction manual

DENAR TRACK II SYSTEM instruction manual DENAR TRACK II SYSTEM instruction manual ACKNOWLEDGEMENTS The Track II System was developed in answer to the many requests from clinicians, dental educators and practicing professionals throughout the

More information

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Two-Piece ReActive Tri-Lobe Implants with Multi-Unit Abutments One-Piece ScrewIndirect Implants

More information

MM01-Facebow And Bite Registration Procedure Checklist

MM01-Facebow And Bite Registration Procedure Checklist MM01-Facebow And Bite Registration Procedure Checklist Bite fork Registration OK Redo 1. Estimate the shape of the patient s arch 2. Place the bite tabs on the bite fork 3. Warm the compound in hot water

More information

Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1)

Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1) Any contact between teeth of opposing dental arches; usually, referring to contact between the occlusal surface. The static relationship between the incising or masticatory surfaces of the maxillary or

More information

Articulators. 5- Wax up and refining the occlusion for dental restorations.

Articulators. 5- Wax up and refining the occlusion for dental restorations. Articulators It is a mechanical device represents the TMJ, maxillary and mandibular arches. It can be used to hold the upper and lower casts according to their relationships to facilitate the purposes

More information

Combi ArtiCulAtor SyStem instruction manual

Combi ArtiCulAtor SyStem instruction manual Denar Combi Articulator System instruction manual table of contents I. Rationale for Development... 2 II. Benefits and Features... 3 III. Set Path Condylar Insert... 5 IV. Adjustable Path Condylar Insert...

More information

Diagnosis 220 Temporary Filling Carrier. Periodontics Periodontal Curette / Sharpener

Diagnosis 220 Temporary Filling Carrier. Periodontics Periodontal Curette / Sharpener Diagnosis 220 Temporary Filling Carrier Periodontics Periodontal Curette / Sharpener Conservative Treatment Composite Syringe / Rubber Dam Punch / Clamp Forceps / Rubber Dam Kit / Reamer Stand / Endodontic

More information

Horizontal jaw relations: The relationship of mandible to maxilla in a

Horizontal jaw relations: The relationship of mandible to maxilla in a Horizontal relations Horizontal jaw relations: The relationship of mandible to maxilla in a horizontal plane (in anteroposterior and side to side direction). a- Protruded or forward relation. b-lateral

More information

MARCY DIAMOND ELITE UTILITY BENCH MD-440. Model MD-440. Retain This Manual for Reference OWNER'S MANUAL

MARCY DIAMOND ELITE UTILITY BENCH MD-440. Model MD-440. Retain This Manual for Reference OWNER'S MANUAL NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Hardware Identifier MARCY DIAMOND ELITE UTILITY BENCH MD-440 Assembly Instruction Parts List Warranty

More information

Trimmer HSS-88 for Orthodontics. For Bite Orientated Trimming of Plaster Jaw Models

Trimmer HSS-88 for Orthodontics. For Bite Orientated Trimming of Plaster Jaw Models Trimmer HSS-88 for Orthodontics For Bite Orientated Trimming of Plaster Jaw Models Wassermann Dental-Maschinen GmbH Rudorffweg 15 17 21031 Hamburg Germany Phone +49 (0)40 730 926-0 Fax: +49 (0)40 730 37

More information

8500 Series Articulator and QuickMount Face-Bow Instruction Manual

8500 Series Articulator and QuickMount Face-Bow Instruction Manual 8500 Series Articulator and QuickMount Face-Bow Instruction Manual 15616 8500 Articulator Instruction Man.indd 1 11/30/10 4:20 PM Whip Mix 8500 Series Articulator Model 8500 2 15616 8500 Articulator Instruction

More information

LEARN FROM A LEADER. Intensive, hands-on training that will prepare you to confidently fabricate the appliances you want.

LEARN FROM A LEADER. Intensive, hands-on training that will prepare you to confidently fabricate the appliances you want. from professionals like, one of the country s most experienced Guide to Orthodontic s... A Comprehensive Resource from Theory to. Brian also has been involved in many patents in the dental field. 2011

More information

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit a perfect fit IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS Open and closed impression-taking Impression-taking for option platform switching Bite registration Temporary

More information

Hanau Series H2 Articulator

Hanau Series H2 Articulator Hanau Series H2 Articulator technique for full denture prosthodontics hanau series h2 articulator technique for full denture prosthodontics This book contains detailed procedures for obtaining an Earpiece

More information

weight.detach/bench ITEM NO: 76310

weight.detach/bench ITEM NO: 76310 weight.detach/bench ITEM NO: 76310 OWNER S MANUAL IMPORTANT: Read all instructions carefully before using this product. Retain this owner s manual for future reference. The specifications of this product

More information

Low Row. User manual E S S E N T I A L S T R E N G T H

Low Row. User manual E S S E N T I A L S T R E N G T H E L E M E N T E S S E N T I A L S T R E N G T H User manual 1 The identification plate of and manufacturer, affixed on the back panel of the weight stack, gives the following details: A B C D E Name and

More information

Introduction to the Panadent System

Introduction to the Panadent System Prosthodontics has changed significantly over the years to the point where patient s acceptance or requests for complete removable dentures has been replaced with requests to save the natural dentition

More information

Supplies. Online. Reliability at a great value. Dentaurum. shop.dentaurum.com

Supplies. Online. Reliability at a great value. Dentaurum. shop.dentaurum.com Impression material Page 296 Laboratory accessories Page 298 Appliance containers and accessories Page 300 Orthodontic study / demonstration models Page 302 Other Page 307 292 . Reliability at a great

More information

USER S MANUAL QUESTIONS? CAUTION. For a great selection of new CD and MP3 workouts. Visit our website at. or call

USER S MANUAL QUESTIONS? CAUTION. For a great selection of new CD and MP3 workouts. Visit our website at.  or call Model No. RBBE950 Serial No. Write the serial number in the space above for future reference. USER S MANUAL Serial Number Decal (Under Seat) QUESTIONS? As a manufacturer, we are committed to providing

More information

The Condyle of the Articulator is a part of the Lower Member and functions as the condyle of the patient s mandible.

The Condyle of the Articulator is a part of the Lower Member and functions as the condyle of the patient s mandible. HANAU WIDE-VUE ARCON ARTICULATORS AND WIDE-VUE II ARTICULATORS ILLUSTRATED INSTRUCTION MANUAL The HANAU Wide-Vue Series of Arcon Articulators INTRODUCTION The HANAU Wide-Vue Articulators are classified

More information

Motorised Treadmill Model No: JI1625

Motorised Treadmill Model No: JI1625 BODYWORX Motorised Treadmill Model No: JI1625 Retain this owner s manual for future reference Read and follow all instructions in this owner s manual Version A 1 TABLE OF CONTENTS OVERVIEW DRAWING 2 ASSEMBLY

More information

Application of ARCUS digma I, II systems for full mouth reconstruction: a case report

Application of ARCUS digma I, II systems for full mouth reconstruction: a case report https://doi.org/10.14368/jdras.2016.32.4.345 ISSN 2384-4353 eissn 2384-4272 Case Report Application of ARCUS digma I, II systems for full mouth reconstruction: a case report Chan Park* Department of Prosthodontics,

More information

Instructions for use for the medical professional English

Instructions for use for the medical professional English English Page 2 of 32 TABLE OF CONTENTS TABLE OF CONTENTS 1 The OPTISLEEP therapeutic appliance... 4 1.1 Indications for use... 5 1.2 Contraindications... 5 2 OPTISLEEP Workflow... 6 3 Determining the treatment

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 37-013 GARD Users Manual March 2005 Manual No. 37-013-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective

More information

SimpleLine II Surgical / Prosthesis Manual

SimpleLine II Surgical / Prosthesis Manual SimpleLine II Surgical / Prosthesis Manual SimpleLine II SURGICAL MANUAL Surgical Drill Sequence 04 Fixture Installation 05 Fixture Connection 06 Surgical Kit Maintenance 08 Warnings 09 04 SimpleLine ll

More information

III Instructions CPI - Condylar Position Indicator. These instructions apply to the following items: h2500 Includes: 9611 D 9615 D

III Instructions CPI - Condylar Position Indicator. These instructions apply to the following items: h2500 Includes: 9611 D 9615 D M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 CPI - III Instructions Condylar Position Indicator These instructions apply to

More information

AD2 MEASURES CONDYLE DISPLACEMENT (MCD) MANUAL

AD2 MEASURES CONDYLE DISPLACEMENT (MCD) MANUAL AD2 MEASURES CONDYLE DISPLACEMENT (MCD) MANUAL Dr. Jorge Ayala Puente, DDS* Dr. Gonzalo Gutiérrez Álvarez, DDS* Dr. José Miguel Obach M., DDS Translation: Dr. Barbara Fernández Lübbert, DDS Edited: Dr.

More information

Calibration and Checking

Calibration and Checking Calibration and Checking BIO-ART ARTICULATORS INSTRUCTION MANUAL i n t e l l i g e n t s o l u t i o n s INDEX 1 - Introduction... 2 - Components of the Bio-Art Calibration and Checking Kit... 3 - Preparation

More information

Element-Z Screw-Retained Hybrid

Element-Z Screw-Retained Hybrid Element-Z Screw-Retained Hybrid Implant-Level Restoration Step-by-Step Restorative Protocol The Element-Z Screw-Retained Hybrid offers a fixed, all-ceramic implant solution for edentulous patients desiring

More information

Stratos 200. Bedienungsanleitung Operating Instructions Mode d emploi Istruzioni d uso Instrucciones de uso

Stratos 200. Bedienungsanleitung Operating Instructions Mode d emploi Istruzioni d uso Instrucciones de uso Stratos 200 Ab Fabr. Nr. 10 000 Valid as of Serial No. 10,000 A partir du n de série 10 000 Dal Nr. di fabbricazione 10.000 A partir del núm. fabric. 10.000 Bedienungsanleitung Operating Instructions Mode

More information

THE ADVANTAGES OF MOUNTING IN SEMI-ADAPTABLE ARTICULATORS IN DENTAL PROSTHETICS

THE ADVANTAGES OF MOUNTING IN SEMI-ADAPTABLE ARTICULATORS IN DENTAL PROSTHETICS THE ADVANTAGES OF MOUNTING IN SEMI-ADAPTABLE ARTICULATORS IN DENTAL PROSTHETICS Călin Mancaş, Paul Freiman, Teodora Eva Lupulescu, Tatiana Duminica Department of Dental Medicine, Faculty of Medicine, Pharmacy

More information

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction Reference to primary publication in ZWP 4/2014 Dr. Marcus Holzmeier, Wuerzburg Xantalgin Crono - Highly accurate alginate impressions. Introduction Even today when digital impression techniques are gaining

More information

AIR WALKER TRAINER USER MANUAL SF-E902

AIR WALKER TRAINER USER MANUAL SF-E902 AIR WALKER TRAINER USER MANUAL SF-E902 IMPORTANT: Read all of the instructions carefully before using this product. Retain the owner s manual for future reference. For customer service, please contact:

More information

Product Specifications and Usage Information P4405, P4410, & P4420 Genesys 30 Dosimeter Holder System

Product Specifications and Usage Information P4405, P4410, & P4420 Genesys 30 Dosimeter Holder System DESCRIPTION The Thermo Genesys 30 Spectrophotometer (G30) is supplied with specially designed dosimeter holders to fit a variety of dosimeters, including the B3 DoseStix and B3 WINdose dosimeters. The

More information

SelectTech 3.1 Bench Assembly / Owner s Manual

SelectTech 3.1 Bench Assembly / Owner s Manual SelectTech 3.1 Bench Assembly / Owner s Manual This product is compliant with the applicable CE requirements. Congratulations on your commitment to fitness and your purchase of the Bowflex SelectTech 3.1

More information

Fibrlok II 2529 Universal Optical Fiber Splice

Fibrlok II 2529 Universal Optical Fiber Splice Fibrlok II 2529 Universal Optical Fiber Splice Instructions January 2007 78-8128-0163-3-E Contents: 1.0 General... 3 2.0 Splicing Set-up... 4 3.0 Fiber Preparation... 5 4.0 Splice Assembly... 6 5.0 For

More information

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. Model No. NTCCBE950 Serial No. Write the serial number in the space above for future reference. USER S MANUAL Serial Number Decal (under seat) QUESTIONS? As a manufacturer, we are committed to providing

More information

CROSS TRAINING MAGNETIC TREADMILL

CROSS TRAINING MAGNETIC TREADMILL CROSS TRAINING MAGNETIC TREADMILL SF-T7615 USER MANUAL IMPORTANT : Read all instructions carefully before using this product. Retain this manual for future reference. For customer service, contact support@sunnyhealthfitness.com

More information

FULL DENTURE SYSTEM THE INHOUSE MOVEMENT

FULL DENTURE SYSTEM THE INHOUSE MOVEMENT EN FULL DENTURE SYSTEM THE INHOUSE MOVEMENT 2 FULL DENTURE PROSTHETICS ACCORDING TO DENTAL TECHNOLOGY LOGIC. PRECISE, CUSTOMISED, AESTHETIC. Ceramill FDS (Full Denture System) describes a completely continuous

More information

8500 Series Articulator and QuickMount Face-Bow Instruction Manual

8500 Series Articulator and QuickMount Face-Bow Instruction Manual 8500 Series Articulator and QuickMount Face-Bow Instruction Manual WHIP MIX 8500 SERIES ARTICULATOR Model 8500 2 CONTENTS INTRODUCTION... 4 OBTAINING FACE-BOW REGISTRATION... 5 I. Preparing Face-Bow...

More information

The Application of the HIP-Analyzer for the Evaluation of the Maxillary Occlusal Plane Topography

The Application of the HIP-Analyzer for the Evaluation of the Maxillary Occlusal Plane Topography The Application of the HIP-Analyzer for the Evaluation of the Maxillary Occlusal Plane Topography Sergey Shestopalov, PhD, DO, Konstantin Ronkin, DMD, MICCMO The orientation of the upper occlusal plane

More information

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE. Model No. WEBE Serial No.

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE.  Model No. WEBE Serial No. www.weiderfitness.com Model No. WEBE9971. Serial No. Write the serial number in the space above for reference. USER S MANUAL Serial Number Decal ACTIVATE YOUR WARRANTY To register your product and activate

More information

A REMINDER OF THE KEY ESTHETIC GUIDELINES AN INTRODUCTION TO THE DITRAMAX DENTAL DEVICE WHAT BENEFITS DOES DITRAMAX OFFER TO THE DENTIST?

A REMINDER OF THE KEY ESTHETIC GUIDELINES AN INTRODUCTION TO THE DITRAMAX DENTAL DEVICE WHAT BENEFITS DOES DITRAMAX OFFER TO THE DENTIST? A REMINDER OF THE KEY ESTHETIC GUIDELINES 1. The incisal plane must be parralel to the interpupillary line, 2. The interincisal midline must be parallel to the facial midline. In order to manufacture prostheses

More information

Manual. HTR 2.0 Ergometer Hometrainer. T +31 (0) e w

Manual. HTR 2.0 Ergometer Hometrainer. T +31 (0) e w HTR 2.0 Ergometer Hometrainer Manual For questions or missing parts please contact Fitness Benelux: Fitness Benelux Uw partner in fitness twekkelerweg 263 7553 lz Hengelo the netherlands T +31 (0)74-7600219

More information

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are inserted in a multiplanar and multi-directional fashion

More information

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions.

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions. Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions. Our phone number is: 908-879-2713 The Ab Coaster Company, 173 Route 206, P.O. Box 9 Chester,

More information

OPERATIVE TECHNIQUE SKS Total Knee Replacement

OPERATIVE TECHNIQUE SKS Total Knee Replacement OPERATIVE TECHNIQUE SKS Total Knee Replacement Femoral preparation A40577 1 2 5 1: Alignment rod A30049 + A30124 2: Centromedullary rod A40224 4: T-handle A40232 6: Femoral measuring device A40411 + A40414

More information

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions.

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions. Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions. Our phone number is: 908-879-2713 The Ab Coaster Company, 173 Route 206, P.O. Box 9 Chester,

More information

Jaw relation registration in RPD

Jaw relation registration in RPD Jaw relation registration in RPD Why to Record the Jaw Relations? To establish and maintain a harmonious relationship with all oral structures and to provide a masticatory apparatus that is efficient and

More information

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD) CHAPTER 17 Tooth preparation for posterior fi xed partial denture (FPD) 1 Defi nition and feature of FPD 2 Actual sequence of tooth preparation for posterior FPD Verify abutment teeth Occlusal guide groove

More information

SURGICAL MODEL ACCURACY DEVICE. 25 years - manufacturing and distribution - around the globe research - design - manufacturing - distribution

SURGICAL MODEL ACCURACY DEVICE. 25 years - manufacturing and distribution - around the globe research - design - manufacturing - distribution SURGICAL MODEL ACCURACY DEVICE 25 years - manufacturing and distribution - around the globe research - design - manufacturing - distribution 2 SMAD - SURGICAL MODEL ACCURACY DEVICE SMAD has be designed

More information

RSD SYSTEM. Owner s Manual

RSD SYSTEM. Owner s Manual RSD SYSTEM Owner s Manual RSD Parts Identification Diagram Index RSD Parts Identification Diagram Page 3 Cord Guide Page 4 Attaching the RSD Page 5 Attaching the Handle Page 6 Screw Cord Guide T-nut Handle

More information

Bowflex Home Gym- PR1000

Bowflex Home Gym- PR1000 Bowflex Home Gym- PR1000 Prepared for Bowflex Prepared by Christine Pfeiffer April 29, 2013 Table of Contents Table of Contents... iii Introduction... 1 Warnings/Preparation Before Assembly... 3 Basic

More information

AN EVALUATION OF MANDIBULAR BORDER MOVEMENTS THEIR CHARACTER AND SIGNIFICANCE

AN EVALUATION OF MANDIBULAR BORDER MOVEMENTS THEIR CHARACTER AND SIGNIFICANCE AN EVALUATION OF MANDIBULAR BORDER MOVEMENTS THEIR CHARACTER AND SIGNIFICANCE HARRY C. LUNDEEN, D.D.S. EDWIN F. SHRYOCK, D.D.S.,M.S. and CHARLES H. GIBBS, PhD. The University of Florida, College of Dentistry,

More information

itensic Trainer Instructions Type: b-effect As at: , Version No. 3, EN

itensic Trainer Instructions Type: b-effect As at: , Version No. 3, EN itensic Trainer Type: b-effect Instructions Table of contents 1 General information 3 1.1 Information about the instructions 3 1.2 Copyright 3 1.3 Sales / Service / Manufacturer 3 1.4 Labels on the trainer

More information

4000 Series Articulator and QuickMount Face-Bow Instruction Manual

4000 Series Articulator and QuickMount Face-Bow Instruction Manual 4000 Series Articulator and QuickMount Face-Bow Instruction Manual WHIP MIX 4000 SERIES ARTICULATORS Model 4640 Model 4641 2 CONTENTS Introduction... 4 Operation Instructions for the Locking Mechanism...

More information

Convex Array Transducer

Convex Array Transducer User Guide Type 8823 Convex Array Transducer English BB1740-C June 2012 For Professional Users Only BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100 / Fax:+45 4452 8199 www.bkmed.com Email:

More information

Fundamentals of Recording & Mounting. Workshop Instructions April 21, Michael J Melkers, DDS, FAGD & Jeanine M McDonald, DDS, FAGD

Fundamentals of Recording & Mounting. Workshop Instructions April 21, Michael J Melkers, DDS, FAGD & Jeanine M McDonald, DDS, FAGD Fundamentals of Recording & Mounting Workshop Instructions April 21, 2016 Michael J Melkers, DDS, FAGD & Jeanine M McDonald, DDS, FAGD NAME OF EXERCISE: Leaf gauge screen OBJECTIVES: Use of a Leaf Gauge

More information

WEIGHT BENCH EXERCISER User s Manual

WEIGHT BENCH EXERCISER User s Manual Model No. 831.15964.1 Serial No. Write the serial number in the space above for reference. WEIGHT BENCH EXERCISER User s Manual Serial Number Decal (under frame) Assembly Operation Maintenance Part List

More information

STEP-BY-STEP-ANLEITUNG

STEP-BY-STEP-ANLEITUNG STEP-BY-STEP-ANLEITUNG VON TECHNIKERN FÜR TECHNIKER LABORATORY PROCEDURES, STEP BY STEP BY TECHNICIANS FOR TECHNICIANS Eclipse junior Laboratory Procedures, Step by Step* Splints Drilling Stents Temporaries

More information

Implant and Tooth Supported Full-Mouth Rehabilitation with Hobo Twin-Stage Technique

Implant and Tooth Supported Full-Mouth Rehabilitation with Hobo Twin-Stage Technique 10.5005/JP-Journals-10012-1099 Koshika Tandon et al CASE REPORT Implant and Tooth Supported Full-Mouth Rehabilitation with Hobo Twin-Stage Technique Koshika Tandon, Ajay Singh, Himanshu Gupta, Rajdeep

More information

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. new products, prizes, fitness tips, and much more!

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.  new products, prizes, fitness tips, and much more! Model No. WEBE44.0 Serial No. Write the serial number in the space above for future reference. USER S MANUAL Serial Number Decal QUESTIONS? As a manufacturer, we are committed to providing complete customer

More information

SP450 OWNER S MANUAL

SP450 OWNER S MANUAL OWNER S MANUAL Product may vary slightly from the item pictured due to model upgrades Read all instructions carefully before using this product. Retain this owner s manual for future reference. NOTE: This

More information

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm STERN ERA IMPLANT ABUTMENT Summary Resilient precision overdenture attachment. Universal hinge with vertical movement. Titanium abutment, nylon male. Manufactured for most popular screw and cylinder implants.

More information

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT INTRODUCTION The torque wrench

More information

MARCY PRO OLYMPIC BENCH

MARCY PRO OLYMPIC BENCH NOTE: Please read all instructions carefully before using this product Table of Contents Safety Notice Important Assembly Information MARCY PRO OLYMPIC BENCH PM-70210 Care and Maintenance Parts List Warranty

More information

Adjustable Ab Board G

Adjustable Ab Board G Exclusively distributed by: RFE UK Ltd The Performance Centre Maidstone Road Kingston, Milton Keynes MK10 0BD, UK + (0)10 73020 sales@goldsgymfitness.com 2010. All rights reserved. Manufactured under license

More information

MemRx Orthodontic Appliances

MemRx Orthodontic Appliances MemRx Orthodontic Appliances Uses and Instructions The MemRx Fundamentals As the need for faster, more efficient treatment of non-compliant patients increases, orthodontic!technology and materials has

More information

IMPORTANT: Please read and follow all instructions thoroughly before using your AB SHREDDER. Maximum user weight is 100 KG. KEEP BODY PARTS, HANDS AND FEET AWAY FROM THE SEAT, WHEELS AND THE CURVED TRACK

More information

ADHESIVE DENTISTRY DR. JAVIER VASQUEZ AN ORDINARY BUT VERY PASSIONATE DENTIST/MASTER CERAMIST DENTAVANTGART MAXIMUM PROTOCOL SIMPLIFICATION

ADHESIVE DENTISTRY DR. JAVIER VASQUEZ AN ORDINARY BUT VERY PASSIONATE DENTIST/MASTER CERAMIST DENTAVANTGART MAXIMUM PROTOCOL SIMPLIFICATION DENTAVANTGART VOLUME VI ISSUE 01 SPRING 2016 INTERVIEW DR. JAVIER VASQUEZ AN ORDINARY BUT VERY PASSIONATE DENTIST/MASTER CERAMIST DR. JON GURREA DEALING WITH THE UNEXPECTED DR. JORDI MANAUTA & DR. DAN

More information

ULTR A SERIES G7-S13

ULTR A SERIES G7-S13 ULTR A SERIES G7-S13 PROPER USAGE 1. Do not exceed weight limits of the exercise device.. If applicable, set safety stops to appropriate height. 3. If applicable, adjust seat pads, leg pads, foot pads,

More information

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments Indications Instructions The Locator Root Attachment is designed for use with overdentures or partial dentures, retained in whole or in part by endodontically treated roots in the mandibular or maxilla.

More information

Impression Manual.

Impression Manual. Impression Manual www.paladigitaldentures.com Contents Page 1 Requirements for Impressions Complete Denture Single Arch Maxillary Denture Single Arch Mandibular Denture Maxillary Impression Maxillary

More information

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE. Model No. WEBE Serial No.

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE.  Model No. WEBE Serial No. www.weiderfitness.com Model No. WEBE15911.0 Serial No. Write the serial number in the space above for reference. USER S MANUAL Serial Number Decal ACTIVATE YOUR WARRANTY To register your product and activate

More information

The fitting process of SomnoGuard

The fitting process of SomnoGuard The fitting process of SomnoGuard Hints to complement the actual user instructions AP Tomed Dr. Toussaint GmbH, 31.07.2010 Needed accessories Spray disinfectant for all working tools Boling water bath

More information

SAFETY LABELS CAUTION: PINCH POINT. Make sure locking pin is fully engaged before beginning forward and side lift exercises.

SAFETY LABELS CAUTION: PINCH POINT. Make sure locking pin is fully engaged before beginning forward and side lift exercises. CONTENTS 3 Important Safety Information 4 Assembly Instructions 6 Adjusting the Seat 6 Getting On and Off the Ab Coaster Max 7 Ab Coaster Max Exercises a. Forward Lift b. Side Lift (Obliques) c. Free-Style

More information