Effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of enamel

Size: px
Start display at page:

Download "Effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of enamel"

Transcription

1 Original Article Effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of enamel Masahiro Iijima a ; Yoshitaka Yasuda b ; Takeshi Muguruma c ; Itaru Mizoguchi d ABSTRACT Objective: To investigate the effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of tooth enamel. Materials and Methods: Fifty-three human premolars were used in this study. The temperature changes of cross-sectioned specimens during laser irradiation were monitored with an infrared thermographic microscope system. Different laser output settings (3, 4, 5, and 6 W) were compared. The shear bond strength of brackets after laser irradiation was measured for specimens bonded with a conventional etch and rinse adhesive or with a self-etching adhesive, and the adhesive remnant index score was calculated. The hardness and elastic modulus of crosssectioned enamel after laser irradiation were investigated by the nanoindentation test. Data were compared by one-way and two-way analysis of variance, followed by the Scheffé test. Results: The temperature of enamel increased by about 200uC under CO 2 laser irradiation with a relatively high output (5 and 6 W), and a temperature increase of about 100uC to 150uC was seen under laser irradiation with a low output (3 and 4 W). The bracket shear bond strength decreased under all laser irradiation conditions. The hardness and elastic modulus of enamel were not affected by CO 2 laser debonding. Conclusion: CO 2 laser debonding may not cause iatrogenic damage to enamel. (Angle Orthod. 2010;80: ) KEY WORDS: Laser debonding; Enamel; Infrared thermography; Shear bond strength; Nanoindentation test INTRODUCTION Most ceramic brackets are made of polycrystalline alumina, single-crystal alumina, or zirconia. 1 A major clinical concern when using ceramic brackets is the risk of enamel damage (fracture) at debonding, 2 since ceramic brackets show a high bracket bond strength 2,3 and are probably difficult to deform because of their characteristic brittleness, with a low ductility and high elastic modulus compared with metal brackets. 1 To avoid enamel fracture, different debonding techniques have been suggested, such as ultrasonic debonding, electrothermal debonding, and the use of specially designed debonding instruments. 4,5 In addition, lasers have been used experimentally to debond ceramic brackets. Laser energy can degrade the adhesive resin as a result of the effects of thermal softening, thermal ablation, and photoablation. 6 It is possible that this heat may propagate to the tooth structure and eventually lead to pulp damage. 2 Although an increase in the pulpal cavity temperature of 5.5uC might cause pulpal necrosis, 7 it has been reported that appropriate laser irradiation decreases the bracket bond strength without a remarkable temperature increase in the pulpal cavity. 2,8 On the other hand, although organic components such as protein and free water comprise only a minor part of mature enamel, they are crucial to its development and are important in understanding its structural organization and physical properties. 9 Previa Associate Professor, Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Health Sciences University of Hokkaido, Hokkaido, Japan. b Private Practice, Nishinomiya, Japan. c Instructor, Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Health Sciences University of Hokkaido, Hokkaido, Japan. d Professor, Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Health Sciences University of Hokkaido, Hokkaido, Japan. Corresponding author: Dr Masahiro Iijima, Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, Health Sciences University of Hokkaido, 1757, Kanazawa, Ishikari-tobetsu, Hokkaido Japan ( iijima@hoku-iryo-u.ac.jp) Accepted: May Submitted: April G 2010 by The EH Angle Education and Research Foundation, Inc. DOI: /

2 1030 IIJIMA, YASUDA, MUGURUMA, MIZOGUCHI ously, He and Swain 10 investigated the effects of heat treatment (300uC) on the mechanical properties of enamel using the nanoindentation test and found that the hardness and elastic modulus of heat-treated enamel were influenced dramatically: the protein matrix and water within burnt enamel were destroyed and removed. The embrittlement of enamel may cause iatrogenic damage to enamel, such as fracture and the creation of other surface defects. No previous studies have studied the effect of laser irradiation on the mechanical properties of enamel. The purposes of this study were to investigate the effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of tooth enamel, such as the hardness and elastic modulus, by the nanoindentation test, while monitoring the temperature change with an infrared thermographic microscope system, and to measure the bracket bond strength. MATERIALS AND METHODS Materials Fifty-three noncarious human premolars were used in this study. The teeth had been extracted for orthodontic reasons with the patients informed consent. Three premolars were used to assess the temperature change during laser debonding by infrared thermography. The remaining teeth were randomly divided into 10 groups of five specimens each for measurements of shear bond strength (SBS) and the nanoindentation test. Selection criteria included the absence of any visible decalcification or cracking of the enamel surface as viewed under a stereoscopic microscope (SMZ 1500, Nikon, Tokyo, Japan) at a magnification of 310. The buccal surfaces of all teeth were cleaned using nonfluoridated pumice. The teeth were also polished using a rubber cup, thoroughly washed, and dried using a moisture-free air source. Assessment of the Change in Temperature Single-crystal brackets (Inspire ice, Ormco, Glendora, Calif) were bonded to the buccal surfaces of premolars with a conventional etch and rinse adhesive system (Transbond XT, 3M Unitek, Monrovia, Calif) according to the manufacturer s instructions. The specimens were stored in artificial saliva at 37uC for 24 hours and then cut horizontally with a slow-speed water-cooled diamond saw at the height of the bracket slot so that they were divided into occlusal and cervical halves; the roots were cut horizontally at approximately 1 cm from the apical surface (Figure 1). The specimen was fixed on the specimen stage of an infrared thermographic microscope system (FSV-GX7000, Apiste, Osaka, Japan) with insulated tape. A CO 2 Figure 1. Schematic illustration of specimen prepared for the infrared thermographic microscope analysis. laser (continuous wave) with a wavelength of 10.6 mm (Nano Laser GL-III, GC, Tokyo, Japan) and a spot diameter of 0.45 mm was applied to one spot (bracket wings) for 5 seconds. The tip of the attachment was positioned as close as possible to the bracket wings (distance: approximately 1 mm). Temperature changes at the surface of the cross-sectioned specimens during laser irradiation and 60 seconds after irradiation were measured using an infrared thermal imaging microscope. Different laser output settings (3, 4, 5, and 6 W) were compared; all experiments were carried out at room temperature. Measurement of SBS Single-crystal brackets were bonded to the buccal surfaces of premolars with either a conventional etch and rinse adhesive system (Transbond XT, 3M Unitek) or a self-etching adhesive system (Transbond Plus, 3M Unitek) according to the manufacturer s instructions. Excess bonding material was removed with an explorer. All samples were light-cured for 10 seconds. After the bonding procedures, the specimens were stored in artificial saliva at 37uC for 24 hours. The specimens were fixed with a custom-fabricated acrylic resin block using Model Repair II (Densply-Sankin, Tokyo, Japan) and the block was fixed with a universal testing machine (EZ Test, Shimadzu, Kyoto, Japan). The CO 2 laser was applied to four spots (each bracket wing) for 5 seconds each. The tip of the attachment was positioned as close as possible to the bracket wings. Different laser output settings (3, 4, 5, and 6 W) were compared for specimens bonded with a conventional etch and rinse adhesive system and those bonded with a self-etching adhesive system (n 5 5 for each system and each adhesive system, with additional sets of nonirradiated specimens serving as

3 CO 2 LASER DEBONDING OF A CERAMIC BRACKET 1031 Figure 2. Schematic illustration of cross-sectioned tooth for the nanoindentation test. controls). After the CO 2 laser was applied, a knifeedged shearing blade was secured to the crosshead with the direction of force parallel to the buccal surface and the bracket base; the brackets were then debonded at a crosshead speed of 0.5 mm/min. After bond failure, the bracket bases and enamel surfaces were examined with a stereoscopic microscope at a magnification of 310. The adhesive remnant index (ARI) scores were used to assess the amount of adhesive left on the enamel surface. ARI scores ranged from 0 to 3: 0 5 no adhesive left on the tooth surface, and the failure site was between the adhesive and the enamel; 1 5 less than half of the adhesive was left on the tooth surface; 2 5 at least half of the adhesive was left on the tooth; 3 5 all of the adhesive was left on the tooth surface, and the failure site was between the adhesive and the bracket base. Nanoindentation Test After SBS was measured, three representative specimens from each condition (a total of 30 specimens) were chosen and divided with a slow-speed water-cooled diamond saw into occlusal and cervical halves. The occlusal halves were then encapsulated in epoxy resin for the nanoindentation test. All samples were ground (600-grit sandpaper) and polished using diamond suspensions (particle sizes of 3, 1, and 0.25 mm) to obtain a suitably polished surface. All nanoindentation testing was carried out at 28uC (ENT- 1100a, Elionix, Tokyo, Japan) with a peak load of 20 mn using a Berkovich indenter. Each test consisted of three parts: 10 seconds for loading to the peak value, 1 second of holding at the peak load, and 10 seconds for unloading. The indentations were placed at depths of 1 to 1001 mm from the surface (20 locations spaced 50 mm apart) in three regions on each specimen (Figure 2). Figure 3 shows a schematic representation of the loading-unloading curve obtained by the nanoindentation testing. Linear extrapolation methods (ISO standard 14577) 11 were used for the unloading curve between 95% and 70% of the Figure 3. Schematic representation of the loading-unloading curve obtained by nanoindentation testing. maximum test force to calculate the elastic modulus. The hardness and elastic modulus were calculated by software available with the nanoindentation apparatus. Statistical Analysis Statistical comparisons were performed with Statistical Package for the Social Sciences software (SPSS Version 16.0J for Windows, Chicago, Ill). The mean SBS values for the 10 specimen groups were compared by one-way and two-way analysis of variance (ANOVA), followed by the Scheffé multiplerange test at the 5% significance level. The two factors for ANOVA were the adhesive material (etch and rinse adhesive system or self-etching adhesive system) and the laser output condition (3, 4, 5, or 6 W). The mean hardness and elastic modulus for the 10 specimen groups were compared by one-way ANOVA followed by the Scheffé multiple-range test at the 5% significance level. The chi-square test was used to evaluate the significance of differences in the ARI scores among the different groups. For the statistical analysis, ARI scores 0 and 1 were combined, as were ARI scores of 2 and 3. RESULTS Representative images obtained 5 seconds after starting CO 2 laser irradiation as registered by the infrared thermographic microscope system are shown in Figure 4. With regard to the change in the temperature of cross-sectioned enamel, irradiation at a relatively high output (5 and 6 W) resulted in an increase of about 200uC, while a low output (3 and 4 W) caused an increase of about 100uC to 150uC. Representative thermographic images at 30 seconds after irradiation by the CO 2 laser are shown in Figure 5. For all of the laser output conditions, the

4 1032 IIJIMA, YASUDA, MUGURUMA, MIZOGUCHI Figure 4. Representative images after 5 seconds of irradiation with a CO2 laser registered by the infrared thermographic microscope system. temperature of cross-sectioned enamel had fallen to room temperature by 30 seconds after irradiation. The SBS results after irradiation with a CO2 laser are shown in Figures 6 and 7. In two-way ANOVA, the adhesive material used (conventional etch and rinse adhesive system vs self-etching adhesive system; P 5.000) was a statistically significant factor. The laser output (3, 4, 5, or 6 W; P 5.000) was also a statistically significant factor. In one-way ANOVA with the Scheffe test, specimens that were bonded with the conventional etch and rinse adhesive system showed a significantly lower SBS than the control (nonirradiated) specimens under any of the laser output conditions. For specimens bonded with self-etching adhesive, irradiation at 3 W resulted in a significantly higher SBS than specimens irradiated at 4, 5, or 6 W, although the value was significantly lower than that of the control specimen. The ARI scores for the 10 groups tested are shown in Table 1. The chi-square test results indicated no significant difference in bond failure sites among the 10 groups. Mean values for hardness and the elastic modulus of cross-sectioned enamel specimens after the measurement of SBS are shown in Figures 8 and 9. Locations at 1 mm from the enamel surface for the specimens bonded with both the etch and rinse adhesive system and the self-etching adhesive system had significantly lower values for hardness and elastic modulus than other locations. The specimens that were irradiated with a CO2 laser and a control specimen showed similar values for hardness and elastic modulus in all locations, and the mean values for locations at 51 to 1001 mm from the enamel surface (hardness: GPa; elastic modulus: GPa) were similar to those obtained in previous reports using the nanoindentation test (hardness: GPa; elastic modulus: GPa). DISCUSSION In this study, the bracket SBS decreased following CO2 laser irradiation; these results agree with those of previous reports.2,6 Previous studies8,12 showed greater bond strength for bisphenol A glycidyl methacrylate resin under laser irradiation than methylmethacrylate resin. The present study compared the bracket SBS for specimens bonded with an etch and rinse adhesive system and a self-etching adhesive system, both of which contained bisphenol A glycidyl methacrylate resin. Specimens irradiated at 3 W showed a similar percentage decrease in SBS, whether they were bonded with a conventional etch and rinse adhesive system (31%) or a self-etching adhesive system (25%), compared to control (nonirradiated) specimens. However, specimens bonded with the self-etching adhesive system showed a remarkable decrease in SBS with an increase in laser output compared with specimens prepared with a conventional etch and rinse adhesive system. The main reason for this may be that the self-etching adhesive systems produce a shallower depth of resin penetration into intact enamel as a result of a milder etching effect compared to conventional etch and rinse adhesive systems13 and therefore it may be possible to deteriorate resin tags using a low laser output. This study used an infrared thermographic microscope system to investigate the change in temperature during the CO2 laser debonding procedure. Infrared thermography is preferred over the thermocouple method to monitor changes in temperature since the temperature can be analyzed over a large area, Figure 5. Representative images after 30 seconds of irradiation with a CO2 laser registered by the infrared thermographic microscope system.

5 CO 2 LASER DEBONDING OF A CERAMIC BRACKET 1033 Table 1. Frequency Distribution of ARI Scores of Tested Groups Figure 6. Means and standard deviations for SBS (in MPa) after irradiation with a CO 2 laser in four specimen groups and one nonirradiated specimen group (control) bonded with a conventional etch and rinse adhesive system. Bars with identical letters indicate that average values are not significantly different (one-way ANOVA and Scheffé multiple-range test; P,.05). although the measurement area is limited to the surface. Therefore, this study used cross-sectioned tooth specimens to monitor the temperature change during a laser debonding procedure; however, the propagation of heat in the enamel close to the surface might be slightly different from that which occurs under actual clinical conditions. Also, the measurement was performed at room temperature, which is lower than typical intraoral temperatures. In addition, measurement of the temperature of the pulpal cavity using a cross-sectioned specimen may be unreasonable because the pulpal cavity is located far from the tooth surface and the propagation behavior of heat is Figure 7. Means and standard deviations for SBS (in MPa) after irradiation with a CO 2 laser in four specimen groups and one nonirradiated specimen group bonded with a self-etching adhesive system. Bars with identical letters indicate that average values are not significantly different (one-way ANOVA and Scheffé multiplerange test; P,.05). Adhesive Conventional etch and rinse Laser Output, W ARI Scores a None (control) Self-etching None (control) a ARI scores: 0 indicates no adhesive left on tooth surface, with the failure site between the adhesive and enamel; 1, less than half of adhesive left on tooth surface; 2 at least half of the adhesive left on tooth; and 3, all adhesive left on tooth surface, with the failure site between the adhesive and the bracket base. ARI scores of 0 and 1 were combined (less than 50% of adhesive left on tooth surface), as were 2 and 3 (50% or more of adhesive left on tooth surface), for the chi-square test. The results showed no statistical difference among groups. different from the actual clinical situation. While a high laser output effectively decreases the bracket bond strength, it is important to consider the damage done to the tooth by heating. 2,7 Previous studies 2 have reported that the increase in the temperature of the pulpal cavity upon laser irradiation was lower than the temperature at which the tooth pulp is necrotized (5.5uC). However, a lower output should help to protect the tooth pulp. A recent study 14 used the nanoindentation test to examine the mechanical properties (hardness and elastic modulus) of the orthodontic wires, and the results were compared with values for hardness and elastic modulus obtained by the conventional Vickers hardness test, three-point bending test, and tension test. The study showed that different testing methods did not yield identical values for elastic modulus and hardness, although the order among the five wire products was always the same; the variations in results can be attributed to the different material volumes being sampled, the different work-hardening levels, and perhaps the effect of the oxide layer on the surface. The nanoindentation test is a suitable method for the evaluation of mechanical properties for small volumes of materials. Another recent study 15 using the nanoindentation test showed that the hardness and elastic modulus of the enamel surface region (1 and 5 mm from the enamel surface) decreased after bracket bonding with a conventional etch and rinse adhesive system, although the self-etching adhesive system showed a minimal decrease in the hardness and elastic modulus of the enamel surface region after bracket bonding. In the present study, the mean hardness and elastic modulus at 1 mm from the

6 1034 IIJIMA, YASUDA, MUGURUMA, MIZOGUCHI Figure 8. Mean values of (a) the hardness and (b) elastic modulus of cross-sectioned enamel specimens bonded with a conventional etch and rinse adhesive system. enamel surface for specimens bonded with a conventional etch and rinse adhesive system or a self-etching adhesive system were significantly lower than those at other locations, although this tendency was stronger for the specimen bonded with the conventional etch and rinse adhesive system because of its stronger etching ability. All of the specimens showed a tendency for decreasing hardness and elastic modulus values with an increase in the distance from the surface (from 51 mm), and this trend is consistent with a previous report. 10 Previous studies 16 have characterized the structural changes in enamel heated from 100uC to 700uC and found that most enamel structures become positively birefringent when heated to 400uC. Another study found that a slight contraction of the alpha-axis dimension in the crystal lattice of enamel apatite occurred at 250uC to 400uC. 17 He and Swain 10 investigated the effects of heat treatment (300uC) on the mechanical properties of enamel using the nanoindentation test and found that the hardness and elastic modulus of heat-treated enamel were dramatically affected, since the protein matrix and water within burnt enamel were destroyed and removed. The mechanical properties such as hardness and elastic modulus observed in the present study were not affected by CO 2 laser irradiation. This is believed to be a result of the fact that the crystal structure of enamel was stable even after CO 2 laser irradiation because the temperature of enamel did not reach 300uC, which was confirmed by monitoring with an infrared thermographic microscope, suggesting that CO 2 laser debonding may not cause iatrogenic damage to enamel. Figure 9. Mean values of (a) the hardness and (b) elastic modulus of cross-sectioned enamel specimens bonded with a self-etching adhesive system.

7 CO 2 LASER DEBONDING OF A CERAMIC BRACKET 1035 CONCLUSIONS N The temperature of cross-sectioned enamel increases by about 200uC under CO 2 laser irradiation with a relatively high output (5 and 6 W), while the temperature increases by about 100uC to 150uC under laser irradiation with low output (3 and 4 W). N The hardness and elastic modulus of enamel are not affected by CO 2 laser irradiation. N CO 2 laser debonding may not cause iatrogenic damage to enamel. ACKNOWLEDGMENT The authors thank Mr Michio Toishi at GC for providing expert technical assistance with the CO 2 laser bracket debonding technique. REFERENCES 1. Eliades T, Eliades G, Brantley WA. Orthodontic brackets. In: Brantley WA, Eliades T, eds. Orthodontic Materials: Scientific and Clinical Aspects. Stuttgart, Germany: Thieme; 2001: Azzeh E, Feldon PJ. Laser debonding of ceramic brackets: a comprehensive review. Am J Orthod Dentofacial Orthop. 2003;123: Odegaard J, Segner D. Shear bond strength of metal brackets compared with a new ceramic bracket. Am J Orthod Dentofacial Orthop. 1988;94: Bishara SE, Trulove TS. Comparison of different debonding techniques for ceramic brackets: an in vitro study. Part I. Background and methods. Am J Orthod Dentofacial Orthop. 1990;98: Swartz M. A history lesson: Inspire sapphire brackets. In: DeCarlo J, ed. Clinical Impressions. Glendora, CA: Ormco; 2001;10: Tocchio RM, Williams PT, Mayer FS, Standing KG. Laser debonding of ceramic orthodontic brackets. Am J Orthod Dentofacial Orthop. 1993;103: Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Path. 1965;19: Hayakawa K. Nd:YAG laser for debonding ceramic orthodontic brackets. Am J Orthod Dentofacial Orthop. 2005;128: Masa MC, Dumont ER. Built to last: the structure, function, and evolution of primate dental enamel. Evolutionary Anthropol. 1999;8: He LH, Swain MV. Influence of environment on the mechanical behavior of mature human enamel. Biomaterials. 2007;28: ISO Metallic Materials Instrumented Indentation Test for Hardness and Materials Parameters Part 1: Test Method. 1st ed. Geneva, Switzerland. International Organization for Standardization; Mimura H, Deguchi T, Obata A, Yamagishi T, Ito M. Comparison of different bonding materials for laser debonding. Am J Orthod Dentofacial Orthop. 1995;108: Fjeld M, Øgaard B. Scanning electron microscopic evaluation of enamel surfaces exposed to 3 orthodontic bonding system. Am J Orthod Dentofacial Orthop. 2006;130: Iijima M, Muguruma T, Brantley WA, Mizoguchi I. Comparison of nanoindentation, three-point bending and tension tests for orthodontic wires. Am J Orthod Dentofacial Orthop. In press. 15. Iijima M, Muguruma T, Brantley WA, Ito S, Yuasa T, Saito T, Mizoguchi I. Effect of bracket bonding on nanomechanical properties of enamel. Am J Orthod Dentofacial Orthop. In press. 16. Oho T, Morioka T. A possible mechanism of acquired acid resistance of human dental enamel by laser irradiation. Caries Res. 1990;24: Fowler BO, Kuroda S. Changes in heated and in laserirradiated human tooth enamel and their probable effects on solubility. Calcif Tissue Int. 1986;38:

Within the past few years, ceramic brackets have

Within the past few years, ceramic brackets have ORIGINAL ARTICLE Debonding of ceramic brackets by a new scanning laser method Mehmet Oguz Oztoprak, a Didem Nalbantgil, a Aysxe Sine Erdem, b Murat Tozlu, b and Tülin Arun c Istanbul, Turkey Introduction:

More information

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location Original paper Dental Materials Journal 21 (1): 32-43, 2002 Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location Toshiko INOUE, Hidekazu TAKAHASHI and Fumio

More information

Ceramic brackets have been the preferred choice

Ceramic brackets have been the preferred choice ORIGINAL ARTICLE Diode laser debonding of ceramic brackets Paul J. Feldon, a Peter E. Murray, b James G. Burch, c Malcolm Meister, c and Matthew A. Freedman d Boca Raton and Fort Lauderdale, Fla Introduction:

More information

Orthodontic In Vivo Bond Strength: Comparison with In Vitro Results

Orthodontic In Vivo Bond Strength: Comparison with In Vitro Results Original Article Orthodontic In Vivo Bond Strength: Comparison with In Vitro Results Kevin L. Pickett, DMD, MS a ; P. Lionel Sadowsky, DMD, BDS, Dip Ortho, M Dent b ; Alex Jacobson, DMD, MDS, MS, PhD c

More information

Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires

Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires Original Article Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires Takeshi Muguruma a ; Masahiro Iijima b ; William A. Brantley c ; Itaru Mizoguchi d ABSTRACT Objective:

More information

Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study

Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study Journal of Dentistry, Tehran University of Medical Sciences Original Article Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study M. Basafa 1, F. Farzanegan 2 1 Professor,

More information

Shear Bond Strength of Acidic Primer, Light-Cure Glass Ionomer, Light-Cure and Self Cure Composite Adhesive Systems - An In Vitro Study

Shear Bond Strength of Acidic Primer, Light-Cure Glass Ionomer, Light-Cure and Self Cure Composite Adhesive Systems - An In Vitro Study Shear Bond Strength of Acidic Primer, Light-Cure Glass Ionomer, Light-Cure and Self Cure Composite Adhesive Systems - An In Vitro Study Krishnakanth Reddy D 1, Kishore M S V 2, Safeena Safeena 3 1 Professor,

More information

Comparison of Shear Bond Strength of Metal Brackets Bonded to Porcelain Surface using Different Surface Conditioning Methods: An in vitro Study

Comparison of Shear Bond Strength of Metal Brackets Bonded to Porcelain Surface using Different Surface Conditioning Methods: An in vitro Study 10.5005/jp-journals-10024-1174 ORIGINAL RESEARCH Comparison of Shear Bond Strength of Metal Brackets Bonded to Porcelain Surface using Different Surface Conditioning Methods: An in vitro Study PV Girish,

More information

Various whitening systems are currently being

Various whitening systems are currently being ORIGINAL ARTICLE Can previously bleached teeth be bonded safely? Tancan Uysal, DDS, a Faruk Ayhan Basciftci, DDS, MS, b Serdar Üşümez, DDS, PhD, b Zafer Sari, DDS, PhD, b and Ahmet Buyukerkmen, DDS a Konya,

More information

A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets

A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets 1 A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets ABSTRACT F. Heravi DDS MS*, R. Naseh DDS MS** Introduction: A large number of orthodontists prefer to rebond the

More information

Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study

Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study The European Journal of Orthodontics Advance Access published February 22, 26 European Journal of Orthodontics of 5 doi:.9/ejo/cji7 The Author 26. Published by Oxford University Press on behalf of the

More information

Assessment of the Confidence of the Adhesive Remnant Index Score With Different Methods

Assessment of the Confidence of the Adhesive Remnant Index Score With Different Methods Original Article Assessment of the Confidence of the Adhesive Remnant Index Score With Different Methods A. Alper Öz; 1 * Sabahat Yazicioğlu; 2 Nursel Arici; 3 Berat Serdar Akdeniz; 4 Naci Murat; 5 and

More information

Original Research. Shear bond strength of new self etching primer (RSEP) Sorake A et al

Original Research. Shear bond strength of new self etching primer (RSEP) Sorake A et al Journal of International Oral Health 2015; 7(7):17-21 Received: 17 th January 2015 Accepted: 10 th April 2015 Conflicts of Interest: None Source of Support: Nil Original Research Comparison of Shear Bond

More information

A Comparison of Bond Strength Between Directand Indirect-bonding Methods

A Comparison of Bond Strength Between Directand Indirect-bonding Methods Marquette University e-publications@marquette School of Dentistry Faculty Research and Publications Dentistry, School of 3-1-2006 A Comparison of Bond Strength Between Directand Indirect-bonding Methods

More information

Early Shear Bond Strength of a One-step Self-adhesive on Orthodontic Brackets

Early Shear Bond Strength of a One-step Self-adhesive on Orthodontic Brackets Original Article Early Shear Bond Strength of a One-step Self-adhesive on Orthodontic Brackets Samir E. Bishara a ; Adam W. Ostby b ; Raed Ajlouni c ; John F. Laffoon d ; John J. Warren e ABSTRACT Objective:

More information

COMPARISON OF SHEAR BOND STRENGTH OF NEW AND RECYCLED BRACKETS WITH DIFFERENT MESH DESIGNS

COMPARISON OF SHEAR BOND STRENGTH OF NEW AND RECYCLED BRACKETS WITH DIFFERENT MESH DESIGNS COMPARISON OF SHEAR BOND STRENGTH OF NEW AND RECYCLED BRACKETS WITH DIFFERENT MESH DESIGNS Author: Dr.Pragati, M.D.S. 3 rd year student Department of Orthodontics, Co-Authors: Prof. Praveen Mehrotra, M.D.S.

More information

The words adhesionpromoters werefirstusedto

The words adhesionpromoters werefirstusedto ORIGINAL ARTICLE Effects of 3 adhesion promoters on the shear bond strength of orthodontic brackets: An in-vitro study Ascensión Vicente, a Luis A. Bravo, b Martín Romero, c Antonio J. Ortíz, d and Manuel

More information

The Effect of Different Bracket Base Cleaning Method on Shear Bond Strength of Rebonded Brackets

The Effect of Different Bracket Base Cleaning Method on Shear Bond Strength of Rebonded Brackets 10.5005/jp-journals-10024-1417 Emad Original F Al Maaitah Research et al The Effect of Different Bracket Base Cleaning Method on Shear Bond Strength of Rebonded Brackets Emad F Al Maaitah, Sawsan Alomari,

More information

The effect of orthodontic bracket pad shape on shear bond strength, an in vitro study on human enamel

The effect of orthodontic bracket pad shape on shear bond strength, an in vitro study on human enamel Journal section: Orthodontics Publication Types: Research doi:10.4317/jced.55121 http://dx.doi.org/10.4317/jced.55121 The effect of orthodontic bracket pad shape on shear bond strength, an in vitro study

More information

Scanning Electron Microscopy Evaluation of the Bonding Mechanism of a Self-etching Primer on Enamel

Scanning Electron Microscopy Evaluation of the Bonding Mechanism of a Self-etching Primer on Enamel Original Article Scanning Electron Microscopy Evaluation of the Bonding Mechanism of a Self-etching Primer on Enamel Julio P. Cal-Neto a ; José Augusto M. Miguel b Abstract: The aim of this study was to

More information

Bond strength assessment of metal brackets bonded to porcelain fused to metal surface using different surface conditioning method

Bond strength assessment of metal brackets bonded to porcelain fused to metal surface using different surface conditioning method ORIGINAL RESEARCH Bond strength assessment of metal brackets bonded to porcelain fused to metal surface using different surface conditioning method Vaishnav PD 1, Philip P 2, Shetty S 3, Mogra S 4, Batra

More information

TECHNICAL GUIDE. For use with CEREC

TECHNICAL GUIDE. For use with CEREC TECHNICAL GUIDE For use with CEREC THE FUTURE AND SOLUTION OF INNOVATIVE ZIRCONIA FEATURES TRANSLUCENCY SIMILAR TO NATURAL TOOTH ENAMEL BY SPEED SINTERING The collaboration of Kuraray Noritake Dental s

More information

ORIGINAL RESEARCH. Sandhya CA Shyam Lohakare, Pushpa Vinay Hazarey ABSTRACT

ORIGINAL RESEARCH. Sandhya CA Shyam Lohakare, Pushpa Vinay Hazarey ABSTRACT ORIGINAL RESEARCH Comparison of shear bond strength of no mix-composite resin, self cure resin reinforced glass ionomer cement and light cure resin reinforced glass ionomer cement: an in-vitro study Sandhya

More information

Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. VAN WAES, H, MATTER, T, KREJCI, Ivo.

Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. VAN WAES, H, MATTER, T, KREJCI, Ivo. Article Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets VAN WAES, H, MATTER, T, KREJCI, Ivo Abstract A mechanical computerized three-dimensional scanner

More information

Enamel surface roughness following debonding using two resin grinding methods

Enamel surface roughness following debonding using two resin grinding methods European Journal of Orthodontics 26 (2004) 333 338 European Journal of Orthodontics vol. 26 no. 3 European Orthodontic Society 2004; all rights reserved. Enamel surface roughness following debonding using

More information

Howard E. Strassler, DMD University of Maryland School of Dentistry

Howard E. Strassler, DMD University of Maryland School of Dentistry Part II National Board Review Operative Dentistry-Biomaterials Structures, chemical properties, physical properties BASIC CONCEPTS ON HOW DENTAL MATERIALS WORK! Howard E. Strassler, DMD University of Maryland

More information

Evaluation of Shear Bond Strength Orthodontic Bracket and Adhesive Remaining Materials on the Enamel Surface Using ARI (Adhesive Remnant Index)

Evaluation of Shear Bond Strength Orthodontic Bracket and Adhesive Remaining Materials on the Enamel Surface Using ARI (Adhesive Remnant Index) Cronicon OPEN ACCESS EC DENTAL SCIENCE Research Article Evaluation of Shear Bond Strength Orthodontic Bracket and Adhesive Remaining Materials on the Enamel Surface Using ARI Rina Sutjiati 1 * and Rudy

More information

Shear bond strength of a new polycarbonate bracketan in vitro study with 14 adhesives

Shear bond strength of a new polycarbonate bracketan in vitro study with 14 adhesives European Journal of Orthodontics 18 (1996) 295-301 O 1996 European Orthodontic Society Shear bond strength of a new polycarbonate bracketan in vitro study with 14 adhesives Nilgun Akin-Nergiz,* Ibrahim

More information

Press Release. Press Contact. The concept for Class II restoration Delicate preparation, rapid procedure and reliable results

Press Release. Press Contact. The concept for Class II restoration Delicate preparation, rapid procedure and reliable results Press Release The concept for Class II restoration Delicate preparation, rapid procedure and reliable results by Dr. Arzu Tuna and Dr. Umut Baysal, Attendorn, Germany Composite restorations have always

More information

Effect of Self-etchant ph on Shear Bond Strength of Orthodontic Brackets: An in vitro Study

Effect of Self-etchant ph on Shear Bond Strength of Orthodontic Brackets: An in vitro Study 10.5005/jp-journals-10015-1126 ORIGINAL RESEARCH Effect of Self-etchant ph on Shear Bond Strength of Orthodontic Brackets: An in vitro Study Amit Goyal, H Jyothikiran, BM Shivalinga WJD ABSTRACT Aims:

More information

AvaDent Bonding Procedure Results: The AvaDent bond exceeds ADA requirements.

AvaDent Bonding Procedure Results: The AvaDent bond exceeds ADA requirements. Tests Summary: AvaDent Bonding Procedure Results: The AvaDent bond exceeds ADA requirements. AvaDent Color Stability Results: AvaDent is more color stable than conventional dentures. AvaDent Acrylic Porosity

More information

Bonding to molars the effect of etch time (an in vitro study)

Bonding to molars the effect of etch time (an in vitro study) European Journal of Orthodontics 20 (1998) 195 199 1998 European Orthodontic Society Bonding to molars the effect of etch time (an in vitro study) Chris D. Johnston*, Donald J. Burden*, David L. Hussey**

More information

Various composite resins are used in orthodontic

Various composite resins are used in orthodontic CLINICIAN S CORNER Four applications of reinforced polyethylene fiber material in orthodontic practice Ali Ihya Karaman, DDS, PhD, a Nihal Kir, DDS, b and Sema Belli, DDS, PhD c Konya, Turkey Four different

More information

Transbond PLUS Color Change Adhesive Lunch and Learn

Transbond PLUS Color Change Adhesive Lunch and Learn Unitek Bonding System Transbond PLUS Color Change Adhesive Lunch and Learn Transbond PLUS Color Change Adhesive Agenda What is Transbond PLUS Color Change Adhesive? Why Transbond PLUS Color Change Adhesive?

More information

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36 GrandTEC Test Kit Dear User, This Test Kit has been put together to enable you to test GrandTEC on the model before using it in a clinical situation. GrandTEC is a resin-impregnated glass fibre strip.

More information

Bond strengths of different orthodontic adhesives after enamel conditioning with the same self-etching primer

Bond strengths of different orthodontic adhesives after enamel conditioning with the same self-etching primer Bond strengths of different orthodontic adhesives after enamel conditioning with the same self-etching primer Rogelio J. Scougall-Vilchis, * Chrisel Zárate-Díaz, Shusuke Kusakabe + and Kohji Yamamoto +

More information

Influence of saliva contamination on the shear bond strength of adhesives on enamel

Influence of saliva contamination on the shear bond strength of adhesives on enamel Influence of saliva contamination on the shear bond strength of adhesives on enamel Tatiana Feres Assad-Loss 1, Mônica Tostes 2, José Nelson Mucha 3 Objective: To evaluate shear bond strength of 3 adhesive

More information

Even though the acid-etching technique is useful

Even though the acid-etching technique is useful SHORT COMMUNICATION Bond failure rates with a self-etching primer: A randomized controlled trial Julio Pedra e Cal-Neto, a Cátia Abdo Quintão, b Marco Antônio de Oliveira Almeida, c and José Augusto Mendes

More information

Metal-Free Restorations PROCEDURES FOR POSTERIOR DIRECT & SEMI-DIRECT COMPOSITE RESTORATIONS D I D I E R D I E T S C H I. For.

Metal-Free Restorations PROCEDURES FOR POSTERIOR DIRECT & SEMI-DIRECT COMPOSITE RESTORATIONS D I D I E R D I E T S C H I. For. PROCEDURES FOR POSTERIOR DIRECT & SEMI-DIRECT COMPOSITE RESTORATIONS Metal-Free Restorations D I D I E R D I E T S C H I The Geneva Smile Center D.M.D, PhD, Privat-Docent 2, Quai Gustave Ador 1207 Geneva

More information

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012 MDJ Evaluation the effect of eugenol containing temporary fillings on shear bond strength of composite restoration Dr. Farid G. Numan B.D.S., M.Sc Abstract The purpose of this in-vitro study was to evaluate

More information

COMPARISON BETWEEN MOLAR BANDS, BONDABLE TUBES AND BONDABLE TUBES WITH FLOWABLE COMPOSITE

COMPARISON BETWEEN MOLAR BANDS, BONDABLE TUBES AND BONDABLE TUBES WITH FLOWABLE COMPOSITE COMPARISON BETWEEN MOLAR BANDS, BONDABLE TUBES AND BONDABLE TUBES WITH FLOWABLE COMPOSITE Azrul Hafiz AA*, Diana MZ, Fitri Octavianti A,Syiral M, Ainuddin Yushar Y, Zurairah I Islamic Science University

More information

An In-Vivo Comparison Of The Efficacy Between Direct And Indirect Bonding Methods

An In-Vivo Comparison Of The Efficacy Between Direct And Indirect Bonding Methods ISPUB.COM The Internet Journal of Dental Science Volume 13 Number 1 An In-Vivo Comparison Of The Efficacy Between Direct And Indirect Bonding Methods P Premanand, A J Shankar Citation P Premanand, A J

More information

Evaluation of Degree of Cure and Shear Bond Strength of a Color Changing Light Cure Adhesive

Evaluation of Degree of Cure and Shear Bond Strength of a Color Changing Light Cure Adhesive 10.5005/jp-journals-10021-1116 ORIGINAL ARTICLE Hanumantha Rao Chidipothu, Shyamala Chandrasekhar Evaluation of Degree of Cure and Shear Bond Strength of a Color Changing Light Cure Adhesive 1 Hanumantha

More information

Comparison of shear bond strength and adhesive remnant index between precoated and conventionally bonded orthodontic brackets

Comparison of shear bond strength and adhesive remnant index between precoated and conventionally bonded orthodontic brackets Guzman et al. Progress in Orthodontics 2013, 14:39 RESEARCH Open Access Comparison of shear bond strength and adhesive remnant index between precoated and conventionally bonded orthodontic brackets Ulises

More information

Structure and mechanical properties of teeth. Advisors: M.A. Meyers & E. A. Olevsky Student :Yen-Shan Lin Date: 6/23/2008

Structure and mechanical properties of teeth. Advisors: M.A. Meyers & E. A. Olevsky Student :Yen-Shan Lin Date: 6/23/2008 Structure and mechanical properties of teeth Advisors: M.A. Meyers & E. A. Olevsky Student :Yen-Shan Lin Date: 6/23/2008 Outline Basic structure and components of teeth Mechanical properties 1. tubule

More information

Department of Orthodontics, Faculty of Dentistry, Mahidol University.

Department of Orthodontics, Faculty of Dentistry, Mahidol University. Dental Journal Tensile properties of general purpose stainless steel wire formed for orthodontic use Pornkiat Churnjitapirom 1, Surachai Dechkunakorn 2, Niwat Anuwongnukroh 2 1 Research Office, Faculty

More information

S. Shear bond strength and debonding characteristics of metal and ceramic

S. Shear bond strength and debonding characteristics of metal and ceramic Journal section: Orthodontics Publication Types: Research doi:10.4317/jced.52658 http://dx.doi.org/10.4317/jced.52658 Shear bond strength and debonding characteristics of metal and ceramic brackets bonded

More information

Shear Bond Strength of Orthodontic Brackets Cured with Different Light Sources under Thermocycling

Shear Bond Strength of Orthodontic Brackets Cured with Different Light Sources under Thermocycling Shear Bond Strength of Orthodontic Brackets Cured with Different Light Sources under Thermocycling Oral Sokucu a Seyda Herguner Siso b Firat Ozturk c Ruhi Nalcaci d ABSTRACT Objectives: The aim of this

More information

The effect of different force magnitudes for placement of orthodontic brackets on shear bond strength, in three adhesive systems

The effect of different force magnitudes for placement of orthodontic brackets on shear bond strength, in three adhesive systems Journal section: Orthodontics Publication Types: Research doi:10.4317/jced.54733 http://dx.doi.org/10.4317/jced.54733 The effect of different force magnitudes for placement of orthodontic brackets on shear

More information

Comparitive Evaluation of Enamel Demineralisation using Conventional Light Cure Composite Resin and RMGIC- An Invivo Study

Comparitive Evaluation of Enamel Demineralisation using Conventional Light Cure Composite Resin and RMGIC- An Invivo Study I J Pre Clin Dent Res 2015;2(7):1-9 July-September All rights reserved International Journal of Preventive & Clinical Dental Research Comparitive Evaluation of Enamel Demineralisation using Conventional

More information

Efficient Bonding Protocol for the Insignia Custom Bracket System

Efficient Bonding Protocol for the Insignia Custom Bracket System Efficient Bonding Protocol for the Insignia Custom Bracket System Abstract The Insignia appliance is reverse-engineered from a digital set-up of the prescribed dental alignment. Each bracket configuration,

More information

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009 DURATEMP Temporary Crown & Bridge Material Temrex Corporation October 2009 DURATEMP Temporary Crown & Bridge Material Overview Product Characteristics Physical Properties Case Report Instructions Ordering

More information

Incognito Appliance System Bonding Protocols Step-by-Step Procedures

Incognito Appliance System Bonding Protocols Step-by-Step Procedures Incognito Appliance System Bonding Protocols Step-by-Step Procedures 2 Incognito Appliance System Bonding Protocols Summary Bonding Protocols Step-by-Step Procedures Adhesives 3 Bonding Dual Cure, RelyX

More information

Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys

Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys Original Article Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys Masahiro Iijima a ; Kazuhiko Endo b ; Toshihiro Yuasa c ; Hiroki Ohno d ; Kazuo Hayashi e ; Mitsugi

More information

Filtek LS Low Shrink Posterior Restorative System Case 1: Cusp build-up

Filtek LS Low Shrink Posterior Restorative System Case 1: Cusp build-up Case 1 This case study focuses on the restoration of an upper molar. Filtek LS Low Shrink Posterior Restorative System Case 1: Cusp build-up The existing, inadequate restoration led to the development

More information

Narendran Sanjana, N. Raghunath; International Journal of Advance Research, Ideas and Innovations in Technology

Narendran Sanjana, N. Raghunath; International Journal of Advance Research, Ideas and Innovations in Technology ISSN: 2454-132X Impact factor: 4.295 (Volume 5, Issue 1) Available online at: www.ijariit.com Comparison of enamel demineralization around orthodontic brackets bonded with conventional etching, self-etch

More information

Fuji II LC. A Perfect Choice

Fuji II LC. A Perfect Choice A Perfect Choice is a remarkable restorative material The world s first resin-reinforced glass ionomer has remained the benchmark for light cured glass ionomer cements, delivering more than 15 years of

More information

ON THE MICROHARDNESS AND YOUNG S MODULUS OF HUMAN TEETH

ON THE MICROHARDNESS AND YOUNG S MODULUS OF HUMAN TEETH ON THE MICROHARDNESS AND YOUNG S MODULUS OF HUMAN TEETH A.D.Zervaki 1, G.N. Haidemenopoulos 1 and A. Giannakopoulos 2 1. Department of Mechanical Engineering, University of Thessaly, Volos, Greece 2. Department

More information

Pulpal Protection: bases, liners, sealers, caries control Module A: Basic Concepts

Pulpal Protection: bases, liners, sealers, caries control Module A: Basic Concepts Readings: Fundamentals of Operative Dentistry, 3 nd Edition; Summitt, et al Chapters 5, 6 and 8 Pulpal Protection: bases, liners, sealers, caries control Module A: Basic Concepts REST 528A Operative #3A

More information

Post Graduate Student, Dept. of Orthodontics, KD Dental College and Hospital, Mathura, UP 2

Post Graduate Student, Dept. of Orthodontics, KD Dental College and Hospital, Mathura, UP 2 Journal section: Orthodontics Publication Types: Research doi:10.4317/jced.53237 http://dx.doi.org/10.4317/jced.53237 Evaluation of surface roughness of enamel after various bonding and clean-up procedures

More information

The Ultimate in Crystal Clear Aesthetics

The Ultimate in Crystal Clear Aesthetics The Ultimate in Crystal Clear Aesthetics SEM x500 SEM x30 SEM x25 SEM x30 Patient Aesthetics The macro photograph shows the clarity of the flawless PURE brackets. Made from pure monocrystalline sapphire

More information

General Properties of Dental Materials Physical properties: 1-Color Translucence

General Properties of Dental Materials Physical properties: 1-Color Translucence The science of dental materials involves a study of the composition and properties of materials and the way in which they interact with the environment in which they are placed. General Properties of Dental

More information

Prophylaxis-based dental treatment: cavity prophylaxis using enamel-protective bracket attachment

Prophylaxis-based dental treatment: cavity prophylaxis using enamel-protective bracket attachment Prophylaxis-based dental treatment: cavity prophylaxis using enamel-protective bracket attachment Author: Thomas Vidahl, Petershagen Orthopaedic jaw treatment that uses brackets and bands puts teeth at

More information

The effectiveness of paint remover to resin adhesive residue on base mesh of metal bracket

The effectiveness of paint remover to resin adhesive residue on base mesh of metal bracket The effectiveness of paint remover to residue on base mesh of metal bracket (Sukarto Abubakar et al.) The effectiveness of paint remover to residue on base mesh of metal bracket Sukarto Abubakar, Bergman

More information

Effects of Two Soft Drinks on Shear Bond Strength and Adhesive Remnant Index of Orthodontic Metal Brackets

Effects of Two Soft Drinks on Shear Bond Strength and Adhesive Remnant Index of Orthodontic Metal Brackets Original Article Effects of Two Soft Drinks on Shear Bond Strength and Adhesive Remnant Index of Orthodontic Metal Brackets Soodabeh Sadat Sajadi 1, Gholamreza Eslami amirabadi 2, Sepideh Sajadi 3 1 Assistant

More information

Adhesive Thickness Effects on the Bond Strength of a Light- Cured Resin-Modified Glass Ionomer Cement

Adhesive Thickness Effects on the Bond Strength of a Light- Cured Resin-Modified Glass Ionomer Cement Original Article Adhesive Thickness Effects on the Bond Strength of a Light- Cured Resin-Modified Glass Ionomer Cement Selim Arici, DDS, MMedSci, PhD a ; Cem Mustafa Caniklioglu, DDS, PhD b ; Nursel Arici,

More information

Article. Reference. Light-curing time reduction with a new high-power halogen lamp. STAUDT, Christine Bettina, et al.

Article. Reference. Light-curing time reduction with a new high-power halogen lamp. STAUDT, Christine Bettina, et al. Article Light-curing time reduction with a new high-power halogen lamp STAUDT, Christine Bettina, et al. Abstract Orthodontic brackets are routinely bonded with light-cured adhesives. Conventional halogen

More information

Microleakage around zirconia crowns after ultrasonic scaling around their margin

Microleakage around zirconia crowns after ultrasonic scaling around their margin Microleakage around zirconia crowns after ultrasonic scaling around their margin Bright Chang D2 Dental Student UAB School of Dentistry Final report (revision) July 26, 2017 Mentors: Nathaniel Lawson,

More information

The Impact of Er,Cr:YSGG Laser Recycling on Shear Bond Strength (SBS) of Stainless Steel Orthodontic Brackets

The Impact of Er,Cr:YSGG Laser Recycling on Shear Bond Strength (SBS) of Stainless Steel Orthodontic Brackets European International Journal of Science and Technology Vol. 3 No. 7 September, 2014 The Impact of Er,Cr:YSGG Laser Recycling on Shear Bond Strength (SBS) of Stainless Steel Orthodontic Brackets Faisal

More information

Comparison of Shear Bond Strength of Orthodontic Brackets Bonded to Enamel Prepared By Er:YAG Laser and Conventional

Comparison of Shear Bond Strength of Orthodontic Brackets Bonded to Enamel Prepared By Er:YAG Laser and Conventional Original Article Comparison of Shear Bond Strength of Orthodontic Brackets Bonded to Enamel Prepared By Er:YAG Laser and Conventional Acid-Etching M.H. Hosseini 1, F. Namvar 2, J. Chalipa 1, K. Saber 3,

More information

BioCoat Featuring SmartCap Technology

BioCoat Featuring SmartCap Technology R R Breakthrough! BioCoat Featuring SmartCap Technology The only bioactive pit and fissure sealant that provides relentless protection through daily release of fluoride, calcium and phosphate ions. Bioactive

More information

A new flash-free orthodontic adhesive system: A first clinical and stereomicroscopic study

A new flash-free orthodontic adhesive system: A first clinical and stereomicroscopic study Original Article A new flash-free orthodontic adhesive system: A first clinical and stereomicroscopic study Moritz Foersch a ; Christian Schuster b ; Roman K. Rahimi c ; Heinrich Wehrbein d ; Collin Jacobs

More information

Assessing the Performance of a Methyl Methacrylate-Based Resin Cement with Self-Etching Primer for Bonding Orthodontic Brackets

Assessing the Performance of a Methyl Methacrylate-Based Resin Cement with Self-Etching Primer for Bonding Orthodontic Brackets Original Article Assessing the Performance of a Methyl Methacrylate-Based Resin Cement with Self-Etching Primer for Bonding Orthodontic Brackets Mayuko Kawasaki, DDS a ; Tohru Hayakawa, PhD b ; Tsutomu

More information

Office reconditioning of stainless steel orthodontic attachments

Office reconditioning of stainless steel orthodontic attachments European Journal of Orthodontics 27 (2005) 231 236 doi:10.1093/ejo/cjh100 The Author 2005. Published by Oxford University Press on behalf of the European Orthodontics Society. All rights reserved. For

More information

Bond Strength of Amorphous Calcium Phosphate Containing Orthodontic Composite Used as a Lingual Retainer Adhesive

Bond Strength of Amorphous Calcium Phosphate Containing Orthodontic Composite Used as a Lingual Retainer Adhesive Original Article Bond Strength of Amorphous Calcium Phosphate Containing Orthodontic Composite Used as a Lingual Retainer Adhesive Tancan Uysal a ; Mustafa Ulker b ; Gulsen Akdogan c ; Sabri Ilhan Ramoglu

More information

Bracket bond strength dependence on light power density. STAUDT, Christine Bettina, KREJCI, Ivo, MAVROPOULOS, Anestis. Abstract

Bracket bond strength dependence on light power density. STAUDT, Christine Bettina, KREJCI, Ivo, MAVROPOULOS, Anestis. Abstract Article Bracket bond strength dependence on light power density STAUDT, Christine Bettina, KREJCI, Ivo, MAVROPOULOS, Anestis Abstract In order to reduce curing time for bracket bonding with light-cured

More information

Flowable Composite for Orthodontic Bracket Bonding (in vitro study)

Flowable Composite for Orthodontic Bracket Bonding (in vitro study) Tikrit Journal for Dental Sciences 1(01)44-50 Flowable Composite for Orthodontic Bracket Bonding (in vitro study) Bahn G. Agha BDS, MSc. (1) Key words flowable composite; shear bond strength; orthodontic

More information

Product Information. ibond Universal All-purpose convenience. Giving a hand to oral health.

Product Information. ibond Universal All-purpose convenience. Giving a hand to oral health. Product Information All-purpose convenience. Giving a hand to oral health. Bonding with confidence. What would you expect from a universal bonding? Durable, reliable bond strength. Convenient and safe

More information

The acid-etch technique has been widely used in

The acid-etch technique has been widely used in ORIGINAL ARTICLE Comparison of bond strength between orthodontic brackets bonded with halogen and plasma arc curing lights: An in-vitro and in-vivo study Michael D. Signorelli, a Elizabeth Kao, b Peter

More information

Hybrid Ceramics Block for CAD/CAM Use Shades: A2, A3, A3.5

Hybrid Ceramics Block for CAD/CAM Use Shades: A2, A3, A3.5 : Developed from Ceramics Cluster Filler, YAMAKIN s Unique Material Shades: A2, A3, A3.5 Outstanding Strength and Durability Evaluation of Biological Safety Flexural Strength Flexural Strength (MPa) 3

More information

OUR EXPERIENCE WITH GRADIA DIRECT IN THE RESTORATION OF ANTERIOR TEETH

OUR EXPERIENCE WITH GRADIA DIRECT IN THE RESTORATION OF ANTERIOR TEETH ISSN: 1312-773X (Online) Journal of IMAB - Annual Proceeding (Scientific Papers) 2006, vol. 12, issue 2 OUR EXPERIENCE WITH GRADIA DIRECT IN THE RESTORATION OF ANTERIOR TEETH Snezhanka Topalova-Pirinska,

More information

DiaDent Group International DIA.DENT DiaRoot BioAggregate. Root Canal Repair Material

DiaDent Group International DIA.DENT   DiaRoot BioAggregate. Root Canal Repair Material DiaDent Group International 1.877.DIA.DENT www.diadent.com DiaRoot BioAggregate Root Canal Repair Material PRECISION. PURITY. RESULTS ABOUT DIAROOT... DiaRoot BioAggregate Root Canal Repair Material is

More information

Improving Tensile Bond Strength of Orthodontic Bracket by Applying Papain Gel as an Deproteinization Agent

Improving Tensile Bond Strength of Orthodontic Bracket by Applying Papain Gel as an  Deproteinization Agent doi: 10.14693/jdi.v24i3.1095 ORIGINAL ARTICLE Improving Tensile Bond Strength of Orthodontic Bracket by Applying Papain Gel as an Email Deproteinization Agent Niswati F. Rosyida 1, Sri Suparwitri 1, Pinandi

More information

Recommended IDB Protocol

Recommended IDB Protocol Recommended IDB Protocol The bonding appointment is critical to fusion treatment since custom wires are designed to work with the bracket positions captured in the scan after bonding. Follow this protocol

More information

Comparison of White MTA And Grey MTA in the Apical Sealing Ability of Lased And Unlased Root Canal Walls - A Pilot Study

Comparison of White MTA And Grey MTA in the Apical Sealing Ability of Lased And Unlased Root Canal Walls - A Pilot Study IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 15, Issue 6 Ver. XIV (June 2016), PP 100-104 www.iosrjournals.org Comparison of White MTA And Grey MTA

More information

A Study on the Adhesion of the Composite Denture. Hiroshi KIMURA*, Takuji YAMAGUCHI*, Tetsuro SHIRAISHI*, Masakazu TSUBOKAWA*, Toshinori HIRAI*

A Study on the Adhesion of the Composite Denture. Hiroshi KIMURA*, Takuji YAMAGUCHI*, Tetsuro SHIRAISHI*, Masakazu TSUBOKAWA*, Toshinori HIRAI* MEMOIRS OF THE FACULTY OF ENGINEERING FUKUI UNIVERSITY VOL.26 No.2 1978 291 A Study on the Adhesion of the Composite Denture Hiroshi KIMURA*, Takuji YAMAGUCHI*, Tetsuro SHIRAISHI*, Masakazu TSUBOKAWA*,

More information

Calibra. Cements. The Simple Choice for Easy Cleanup

Calibra. Cements. The Simple Choice for Easy Cleanup Calibra Cements The Simple Choice for Easy Cleanup www.calibracement.com The Calibra family of definitive cements was designed to make it easier than ever to achieve consistent, successful results in your

More information

Bending strengths and hardness of autopolymerized acrylic resin

Bending strengths and hardness of autopolymerized acrylic resin Bending strengths and hardness of autopolymerized acrylic resin Tomoko Osada, DMD, PhD, Takako Ishimoto, DMD, PhD, Takayuki Aoki, DMD, PhD, Yasunori Suzuki, DMD, PhD, Norio Takishin, DDS, PhD, Chikahiro

More information

Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique

Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique SCIENTIFIC ARTICLE Australian Dental Journal 2006;51:(2):175-179 Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique GM Knight,* JM McIntyre,* Mulyani*

More information

A comparison of shear bond strength and mean survival time between treated and untreated mesh backed stainless steel brackets, an in-vitro assessment.

A comparison of shear bond strength and mean survival time between treated and untreated mesh backed stainless steel brackets, an in-vitro assessment. (J lnd Orthod Soc 2002; 35:124 128) RESEARCH ARTICLE - A comparison of shear bond strength and mean survival time between treated and untreated mesh backed stainless steel brackets, an in-vitro assessment.

More information

Non-osseointegrated. What type of mini-implants? 3/27/2008. Require a tight fit to be effective Stability depends on the quality and.

Non-osseointegrated. What type of mini-implants? 3/27/2008. Require a tight fit to be effective Stability depends on the quality and. Non-osseointegrated What type of mini-implants? Require a tight fit to be effective Stability depends on the quality and quantity of cortical and trabecular bone. Osseointegrated Non-osseointegrated AbsoAnchor

More information

Frictional Behavior and Surface Failure of Human Enamel

Frictional Behavior and Surface Failure of Human Enamel Frictional Behavior and Surface Failure of Human Enamel J. M. POWERS, R. G. CRAIG, and K. C. LUDEMA School of Dentistry, University of Michigan, Ann Arbor, Michigan 48104, USA, and College of Engineering,

More information

Introducing the Clarity SL Self-Ligating Appliance System

Introducing the Clarity SL Self-Ligating Appliance System Introducing the Clarity SL Self-Ligating Appliance System Lunch and Learn Agenda Clarity SL Brackets Overview Consultation Benefits Bracket Positioning Benefits Bonding Benefits Leveling & Aligning Benefits

More information

Operative dentistry. Lec: 10. Zinc oxide eugenol (ZOE):

Operative dentistry. Lec: 10. Zinc oxide eugenol (ZOE): Operative dentistry Lec: 10 د.عبذالمنعم الخفاجي Zinc oxide eugenol (ZOE): There are 2 types: 1) Unreinforced ZOE (ordinary type): supplied as powder (zinc oxide + some additives like zinc acetate, white

More information

Transbond IDB Pre-Mix Chemical Cure Adhesive Lunch and Learn

Transbond IDB Pre-Mix Chemical Cure Adhesive Lunch and Learn Transbond IDB Pre-Mix Chemical Cure Adhesive Lunch and Learn Agenda Transbond IDB Pre-Mix Chemical Cure Adhesive Value Proposition Product Claims Features Advantages Benefits Product Consideration Technical

More information

BioCoat Featuring SmartCap Technology

BioCoat Featuring SmartCap Technology new! BioCoat Featuring SmartCap Technology Premier s new bioactive pit and fissure sealant provides relentless protection, outstanding adhesion and extended fluoride release. Bioactive Release - Uptake

More information

Effect of simulated debracketing on enamel damage

Effect of simulated debracketing on enamel damage Journal of the Formosan Medical Association (2012) 111, 560e566 Available online at www.sciencedirect.com journal homepage: www.jfma-online.com ORIGINAL ARTICLE Effect of simulated debracketing on enamel

More information

Bond Strength of Disinfected Metal and Ceramic Brackets:

Bond Strength of Disinfected Metal and Ceramic Brackets: Original Article Bond Strength of Disinfected Metal and Ceramic s: An In Vitro Study Cornelia Speer a ; Dorothee Zimny b ; Werner Hopfenmueller c ; Eva Andrea Holtgrave d Abstract: The aim of this in vitro

More information

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post Abstract Aims: The aim of this study was to compare the attachment of different composite resin luting cements

More information

Effects of silanation time on shear bond strength between a gold alloy surface and metal bracket

Effects of silanation time on shear bond strength between a gold alloy surface and metal bracket Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 2005-372X Effects of silanation time on shear bond strength between a gold alloy surface and metal bracket Min-Ho Jung a Won-Jun

More information