Science Behind Insulin Delivery

Size: px
Start display at page:

Download "Science Behind Insulin Delivery"

Transcription

1 Science Behind Insulin Delivery 1

2 Overview Objective The objective of this presentation is to demonstrate why insulin pump therapy is more effective than multiple daily shots in delivering superior outcomes Key Points By reviewing this presentation you can learn how an insulin pump: Works more like a healthy pancreas Allows to create multiple basal rates Leads to more accurate bolus dosing Creates more predictable glucose lowering effect 2

3 Normal Insulin Production: The Pancreas A healthy pancreas releases insulin automatically, on average, every 10-to 14-minutes 1, in amounts appropriate for your varying blood glucose levels. Insulin Normal Insulin Secretion 0 hr 12 hrs 24 hrs Adapted from 1. Marchetti, P, et al. Diabetes, Vol 43, p , June Schematic representation only 3

4 There Are Big Gaps Between Pancreas Insulin Production and Conventional Therapy NPH and Short-Acting Insulin Injection Injection Normal Insulin Secretion Short-acting Insulin NPH Insulin 0 hr Schematic representation only 12 hrs 24 hrs 4

5 Intensive Diabetes Management with Injections Is Better But Leaves Room for Opportunity Lantus basal insulin plus rapid-acting insulin before meals Requires 4 5 injections / day Injection Injection Injection Injection Insulin Normal Insulin Secretion Rapid-acting Insulin Lantus 0 hr 12 hrs 24 hrs Schematic representation only. Lantus is a registered trademark of Aventis Pharmaceuticals. 5

6 When compared to multiple daily injections (MDI), CSII results in: Better metabolic control (improved A1C and fewer excursions) Less hypoglycemia Better patients satisfaction and quality of life CSII is the most physiological method of insulin delivery currently available Consensus statement on use of insulin pumps in pediatrics endorsed by the ADA and European Association for the Study of Diabetes (EASD) Phillip M, Battelino T, Rodriguez H, et al. Diabetes Care. 2007;30:

7 Basal Insulin Needs Vary Throughout the Day age 3-10 age age age >60 units/hour n= a 2-3a 4-5a 6-7a 8-9a 10-11a 12-1p hour 2-3p 4-5p 6-7p 8-9p 10-11p Results indicate it is not reasonable to expect basal insulin needs to be met by a flat rate of insulin delivery for 24 hours. Scheiner, Gary; Boyer, Bret A. Characteristics of basal insulin requirements by age and gender in Type-1 diabetes patients using insulin pump therapy. Diab Res and Clin Prac, 69 (2005) pg

8 Insulin Pump Users Program Multiple Basal Rates According to Their Daily Routine A typical profile of basal insulin rates in CSII. Many people are more active in the late afternoon, and more sedentary after dinner, necessitating adjustment to the basal rate. Note higher basal rate in pre-dawn hours Lenhard MJ, Reeves GD. Arch Intern Med. 2001;161: Reused with permission. 8

9 Insulin Pumps Also Deliver Customized Boluses for Different Types of Meals Insulin pumps offer smart calculators to help determine how much bolus insulin is needed, and can deliver precise amounts of insulin based on the amount of carbs to be taken. Lenhard MJ, Reeves GD. Arch Intern Med. 2001;161: Reused with permission. 9

10 Insulin Pumps Use Only Rapid Acting Insulin which Has the Least Intrapatient Variability Pharmacodynamic Variability in Insulin Action* Rapid-acting insulin 16% Rapid-acting insulin has the lowest intrapatient variability Glargine 36% NPH insulin 46% *Percentages represent the coefficients of variation (CV) for insulin action as measured by the maximum glucose infusion rate in these euglycemic glucose clamp studies Heinemann L, Weyer C, Rauhaus M, Heinrichs S, Heise T. Diabetes Care. 1998;21: ; Heise T, Nosek L, Rønn BB, et al. Diabetes. 2004; 53:

11 Injections with Long-acting Insulin Can Have Different Glucose Lowering Effects from Day-to-Day Deposit up to a full day s dose of insulin under the skin Expectation is that it will be used at the same rate, day-in and day-out Glucose lowering effect of intermediate and long-acting insulin can vary up to 46% *, which explains drastic day-to-day variations in glucose levels despite using the same amount *Heise T. Diabetes Care. 1998;21: ; Heise T, Nosek L, Rønn BB, et al. Diabetes. 2004; 53:

12 Medtronic Diabetes Devonshire Street Northridge, CA MINIMED ( ) 12

Clinical Evidence for Insulin Pump Therapy

Clinical Evidence for Insulin Pump Therapy Clinical Evidence for Insulin Pump Therapy 9501169-011 Objective Review the clinical evidence supporting the use of insulin pump therapy Key Points The benefits of CSII are: Improved metabolic control

More information

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University Pumps & Sensors made easy OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University DeFronzo RA. Diabetes. 2009;58:773-795. Ominous Octet Relationship of b-cell Dysfunction and Development

More information

Insulin pump therapy. Healthy Living with Diabetes

Insulin pump therapy. Healthy Living with Diabetes Insulin pump therapy Healthy Living with Diabetes 1 AGENDA Why Insulin Pump Therapy Pump Therapy Overview Benefits of Pump Therapy Getting Started on Pump Therapy 2 WHY INSULIN PUMP THERAPY UMPWHY INSULIN

More information

MINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD

MINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD MINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD USE AND EXAMPLES Rich Flores, RD Diabet es Clinical Manger Northern Minnesota/ St. Cloud WARNING: Territory Medtronic performed an evaluation of the MiniMed

More information

Diabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE

Diabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE Diabetes and Technology Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE Disclosure Speaker s Bureau: Janssan Pharmaceuticals Current Technology V-Go by Valeritas Continuous Sensors (personal

More information

Using the Bolus Wizard Calculator

Using the Bolus Wizard Calculator 9501179-011 Using the Bolus Wizard Calculator Objective Describe the features and benefits of the Bolus Wizard Calculator Key Points The Bolus Wizard: Estimates high blood glucose corrections using the

More information

Pumping Insulin is it for your patients?

Pumping Insulin is it for your patients? Pumping Insulin is it for your patients? YOU CAN make managing diabetes easier. Fred Porcase D.O. Disclosures to Participants Conflicts Of Interest and Financial Relationships Disclosures: No professional

More information

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes CareLink Management Software for Diabetes software REPORT REFERENCE GUIDE How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used

More information

Report Reference Guide

Report Reference Guide Report Reference Guide How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used to generate the sample reports was from sample patient

More information

INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. * NOW APPROVED FOR AGES 7 AND UP. Waterproof to a depth

More information

INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. * NOW APPROVED FOR AGES 7 AND UP. MORE TIME HERE TO USING

More information

The Realities of Technology in Type 1 Diabetes

The Realities of Technology in Type 1 Diabetes The Realities of Technology in Type 1 Diabetes May 6, 2017 Rosanna Fiallo-scharer, MD Margaret Frederick, RN Disclosures I have no conflicts of interest to disclose I will discuss some unapproved treatments

More information

Technology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE

Technology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE Technology for Diabetes: 101 Basic Rules of the Road Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE Quick Pump Facts! o Constant insulin supply o Pager-sized mini-computer worn

More information

Welcome to CareLink Pro

Welcome to CareLink Pro Reference Guide Welcome to CareLink Pro This guide was developed to serve as a reference for obtaining patient data and reviewing CareLink Pro reports. Getting Started with CareLink Pro Adding New Patients

More information

Getting Started. Learning Guide. with Insulin Pump Therapy. PUMP Foundations. for the MiniMed 530G with Enlite

Getting Started. Learning Guide. with Insulin Pump Therapy. PUMP Foundations. for the MiniMed 530G with Enlite Getting Started with Insulin Pump Therapy for the MiniMed 530G with Enlite Learning Guide PUMP Foundations MiniMed 530G Insulin Pump Settings Form: We recommend that you record all settings on this form

More information

Clinical Value and Evidence of Continuous Glucose Monitoring

Clinical Value and Evidence of Continuous Glucose Monitoring Clinical Value and Evidence of Continuous Glucose Monitoring 9402313-012 Objective To review the clinical value and the recent clinical evidence for Professional and Personal CGM Key Points CGM reveals

More information

Performance-powered. The OneTouch. Ping insulin pump and meter-remote.

Performance-powered. The OneTouch. Ping insulin pump and meter-remote. Performance-powered. The OneTouch Ping insulin pump and meter-remote. I We don t just deliver insulin. We deliver outstanding clinical performance. P36337_OTP_DetAid_OmniPodUpdate_r12.indd 1 OneTouch Ping.

More information

CGM Therapy Expert Program

CGM Therapy Expert Program CGM Therapy Expert Program PROGRAM OVERVIEW The Medtronic-Bayer CGM Therapy Expert Program is designed to update healthcare professionals on the most current scientific and technical information regarding

More information

This certificate-level program is non-sponsored.

This certificate-level program is non-sponsored. Program Name: Diabetes Education : A Comprehensive Review Module 5 Intensive Insulin Therapy Planning Committee: Michael Boivin, B. Pharm. Johanne Fortier, BSc.Sc, BPh.LPh, CDE Carlene Oleksyn, B.S.P.

More information

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical Practice Guideline Task Force Members Anne Peters, MD (Chair)

More information

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes Sarah Dombrowski, PharmD, BCACP Pennsylvania Pharmacists Association 10/20/18 1 Objectives At the completion of this activity,

More information

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

THERAPY MANAGEMENT SOFTWARE FOR DIABETES THERAPY MANAGEMENT SOFTWARE FOR DIABETES Report Report Interpretation Reference Guide Guide 2009 Medtronic MiniMed. All rights reserved. 6025274-012_a CareLink Pro Report Reference Guide 0 p.2 Adherence

More information

Self-Monitoring Blood Glucose (SMBG) Frequency & Pattern Tool

Self-Monitoring Blood Glucose (SMBG) Frequency & Pattern Tool Self-Monitoring Blood Glucose () Pattern Recommendation: Basal Insulin Only (To Target) NPH or long-acting analogue, typically given at. at least as often as is being given. Optional, less frequent can

More information

Insulin Pump Therapy

Insulin Pump Therapy Patient and Family Education Insulin Pump Therapy The insulin pump is a device that gives insulin to the body at a steady rate. With the pump you won t need daily shots. This handout describes how insulin

More information

Designed with your patients lives in mind

Designed with your patients lives in mind The Accu-Chek Insight diabetes therapy system Designed with your patients lives in mind With pre-filled insulin cartridge Designed for easy patient training The Accu-Chek Insight diabetes therapy system

More information

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK) Insulin Pump Therapy in children Prof. Abdulmoein Al-Agha, FRCPCH(UK) aagha@kau.edu.sa Highlights Evolution of insulin pump Pumps mimics Pancreas Goals of diabetes care What lowers HbA1c Criteria for selection

More information

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond) Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond) 9501366-011 20110401 Objectives Understand the need for insulin pumps and CGMS in managing

More information

Diabetes Management in Toddlers/Preschoolers (<6 yo)

Diabetes Management in Toddlers/Preschoolers (<6 yo) Diabetes Management in Toddlers/Preschoolers (

More information

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

THERAPY MANAGEMENT SOFTWARE FOR DIABETES THERAPY MANAGEMENT SOFTWARE FOR DIABETES Report Report Interpretation Reference Guide Guide 2007 Medtronic MiniMed. All rights reserved. 6025274-0U2 120707 CareLink Pro Report Reference Guide 0 p.2 Sensor

More information

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE Indicated for type 1 patients 14 and over. Prescription required. WARNING: Medtronic performed an evaluation of the MiniMed 670G system and determined that it

More information

WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES?

WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES? Christian In better control with his pump since 2012 WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES? Many people with Type 1 diabetes worry about potential long-term

More information

Insulin Pump Therapy. WakeMed Children s Endocrinology & Diabetes WakeMed Health & Hospitals Version 1.3, rev 5/21/13 MP

Insulin Pump Therapy. WakeMed Children s Endocrinology & Diabetes WakeMed Health & Hospitals Version 1.3, rev 5/21/13 MP Insulin Pump Therapy WakeMed Children s Endocrinology & Diabetes Overview What is an insulin pump? What are the advantages and disadvantages of an insulin pump? Lifestyle Changes Food Management Exercise

More information

New basal insulins Are they any better? Matthew C. Riddle, MD Professor of Medicine Oregon Health & Science University Keystone Colorado 15 July 2011

New basal insulins Are they any better? Matthew C. Riddle, MD Professor of Medicine Oregon Health & Science University Keystone Colorado 15 July 2011 New basal insulins Are they any better? Matthew C. Riddle, MD Professor of Medicine Oregon Health & Science University Keystone Colorado 15 July 2011 Presenter Disclosure I have received the following

More information

Type I Type II Insulin Resistance

Type I Type II Insulin Resistance Insulin An aqueous hormonal solution made in the pancreas. Affects metabolism by allowing glucose to leave the blood and enter the body cells, preventing hyperglycemia. It is measured in units, e.g. 100

More information

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES Many parents whose child is diagnosed with Type 1 diabetes wonder: Why is this happening to my child?

More information

UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE

UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE The insulin pump Replaces injections Delivers insulin through a soft cannula

More information

OneTouch Reveal web app Report Reference Guide

OneTouch Reveal web app Report Reference Guide OneTouch Reveal web app Report Reference Guide Your step-by-step guide to setting up and using the OneTouch Reveal web app OneTouch Verio meter OneTouch Verio Flex meter OneTouch Verio IQ meter OneTouch

More information

Effective Health Care Program

Effective Health Care Program Comparative Effectiveness Review Number 57 Effective Health Care Program Methods for Insulin Delivery and Glucose Monitoring: Comparative Effectiveness Executive Summary Background Diabetes mellitus is

More information

MANAGEMENT OF TYPE 1 DIABETES MELLITUS

MANAGEMENT OF TYPE 1 DIABETES MELLITUS MANAGEMENT OF TYPE 1 DIABETES MELLITUS INVESTIGATIONS AND TREATMENT MANSI NAIK VII SEMESTER INVESTIGATIONS FASTING BLOOD SUGAR PLASMA GLUCOSE HEMOGLOBIN A 1c SYMPTOMS OF TYPE 1 DIABETES MELLITUS Polyuria

More information

CANDY Camp Application

CANDY Camp Application CANDY Camp Application Please complete the following form and submit it by June 15, 2016. Please mail form to Bonnie Kruse, Diabetes Program Coordinator, HSHS St. Anthony s Memorial Hospital, 503 North

More information

Role of Academia In Achieving Targets in Diabetes Care

Role of Academia In Achieving Targets in Diabetes Care Role of Academia In Achieving Targets in Diabetes Care Disclosures Member of NovoNordisk, Lilly, Metavention, Sanofi, and Janssen Diabetes Advisory Boards Role of Academia in Discovering New Treatments

More information

INSULIN THERAY دکتر رحیم وکیلی استاد غدد ومتابولیسم کودکان دانشگاه علوم پزشکی مشهد

INSULIN THERAY دکتر رحیم وکیلی استاد غدد ومتابولیسم کودکان دانشگاه علوم پزشکی مشهد INSULIN THERAY DIABETES1 IN TYPE دکتر رحیم وکیلی استاد غدد ومتابولیسم کودکان دانشگاه علوم پزشکی مشهد Goals of management Manage symptoms Prevent acute and late complications Improve quality of life Avoid

More information

Insulin Pump Therapy for Type 2

Insulin Pump Therapy for Type 2 9501172-011 Insulin Pump Therapy for Type 2 Objective To show the effectiveness of CSII for insulin-taking type 2 patients Key Points Tight glycemic control decreases risk of diabetes-related complications

More information

Adjusting Insulin Doses

Adjusting Insulin Doses Adjusting Insulin Doses Everyone with diabetes, including you, will need to adjust your insulin doses at some time. There are several reasons why a person may need an insulin adjustment. These reasons

More information

Real-Time Continuous Glucose Monitoring: From Application to Evaluation

Real-Time Continuous Glucose Monitoring: From Application to Evaluation Real-Time Continuous Glucose Monitoring: From Application to Evaluation Gary Scheiner MS, CDE Owner/Director, Integrated Diabetes Services 333 E. Lancaster Ave., Suite 24 Wynnewood, PA 1996 (877) 735-3648

More information

Insulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education

Insulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education Insulin Pumps and Continuous Glucose Sensors- Embracing Technology Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education Diabetes Management Tools in 1974 Insulin pump history

More information

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1 Report Reference Guide THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1 How to use this guide Each type of CareLink report and its components are described in the following sections.

More information

Understanding the Assessment and Progress Report

Understanding the Assessment and Progress Report Understanding the ssessment and Progress Report ssessment and Progress 8//2-8/7/2 (7 Days) 3 7/2/2-7/27/2 (7 Days) 4 25-75% -% verage 2 4: M- 5:4 M Hyperglycemic patterns() :45 PM- :3 PM 2 3 :2 M- :5 M

More information

Type 1 DM. CME Away India & Sri Lanka March 23 - April 7, 2018

Type 1 DM. CME Away India & Sri Lanka March 23 - April 7, 2018 Type 1 DM CME Away India & Sri Lanka March 23 - April 7, 2018 Richard A. Bebb MD, ABIM, FRCPC Consultant Endocrinologist Medical Subspecialty Institute Cleveland Clinic Abu Dhabi Copyright 2017 by Sea

More information

Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier??

Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier?? Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier?? Moshe Phillip Institute of Endocrinology and Diabetes National Center of Childhood Diabetes Schneider

More information

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim Division of Endocrinology and Metabolism, Samsung Medical Center, Sungkyunkwan University School of Medicine Conflict of interest

More information

Making the Most of Continuous Glucose Monitoring

Making the Most of Continuous Glucose Monitoring Making the Most of Continuous Glucose Monitoring Gary Scheiner MS, CDE Owner & Clinical Director Integrated Diabetes Services LLC Wynnewood, PA AADE 2014 Diabetes Educator of the Year gary@integrateddiabetes.com

More information

What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes?

What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes? What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes? Dr. Fiona Wotherspoon Consultant in Diabetes and Endocrinology Dorset County Hospital Fiona.Wotherspoon@dchft.nhs.uk

More information

Confusion Regarding Duration of Insulin Action: A Potential Source for Major Insulin Dose Errors by Bolus Calculators

Confusion Regarding Duration of Insulin Action: A Potential Source for Major Insulin Dose Errors by Bolus Calculators 4319DSTXXX10.1177/1932296813514319Journal of Diabetes Science and TechnologyWalsh et al 014 Commentary Confusion Regarding Duration of Insulin Action: A Potential Source for Major Insulin Dose Errors by

More information

Position Statement of ADA / EASD 2012

Position Statement of ADA / EASD 2012 Management of Hyperglycemia in Type2 Diabetes: A Patient- Centered Approach Position Statement of ADA / EASD 2012 Cause of : Type 2 diabetes Cardiovascular disorders Blindness End-stage renal failure Amputations

More information

Advances in Diabetes Care Technologies

Advances in Diabetes Care Technologies 1979 Advances in Diabetes Care Technologies 2015 Introduction Insulin pump use: ~ 20% - 30% of patients with T1DM < 1% of insulin-treated patients with T2DM 2007 FDA estimates ~375,000 insulin pumps for

More information

Advances in Diabetes Care Technologies

Advances in Diabetes Care Technologies 1979 Advances in Diabetes Care Technologies 2015 Introduction Roughly 20% - 30% of patients with T1DM and fewer than 1% of insulin-treated patients with T2DM use an insulin pump In 2007, the US FDA estimated

More information

USING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User

USING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User USING THE MINIMED 670G SYSTEM Instructions for the Experienced MiniMed 630G System User This is a supplemental guide. For complete instructions and safety information, please see your MiniMed 670G System

More information

USING THE MINIMED 670G SYSTEM

USING THE MINIMED 670G SYSTEM USING THE MINIMED 670G SYSTEM Instructions for the Experienced MiniMed 630G System User USING THE MINIMED 670G SYSTEM: INSTRUCTIONS FOR THE EXPERIENCED USER Checklist for starting on your MiniMed 670G

More information

DIAGNOSIS OF DIABETES NOW WHAT?

DIAGNOSIS OF DIABETES NOW WHAT? DIAGNOSIS OF DIABETES NOW WHAT? DISCUSS GOALS FOR DIABETES CARE IDENTIFY COMMON COMPLIANCE- ADHERENCE ISSUES DESCRIBE TECHNOLOGY TO ASSIST AND / OR IMPROVE DIABETES CARE WHAT DO WE WANT OUR PATIENTS TO

More information

MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE TO TAKE CONTROL OF YOUR DIABETES

MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE TO TAKE CONTROL OF YOUR DIABETES MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE OF YOUR DIABETES HAVE YOU CONSIDERED THE REAL IMPACT HYPOS HAVE ON YOUR LIFE? AN ESTIMATED 1 HOUR EVERY DAY IS LOST TO THE MANAGEMENT OF 43% OF PEOPLE

More information

EAST OF ENGLAND CHILDREN AND YOUNG PEOPLE S DIABETES NETWORK. Optimising Glycaemic Control for Children and Young People with Diabetes

EAST OF ENGLAND CHILDREN AND YOUNG PEOPLE S DIABETES NETWORK. Optimising Glycaemic Control for Children and Young People with Diabetes EAST OF ENGLAND CHILDREN AND YOUNG PEOPLE S DIABETES NETWORK Optimising Glycaemic Control for Children and Young People with Diabetes Local diabetes teams need to take on the responsibility of ensuring

More information

USE OF INSULIN PUMP FOR THE 1 ST TIME IN A GOVERNMENT HOSPITAL JJ HOSPITAL, MUMBAI

USE OF INSULIN PUMP FOR THE 1 ST TIME IN A GOVERNMENT HOSPITAL JJ HOSPITAL, MUMBAI USE OF INSULIN PUMP FOR THE 1 ST TIME IN A GOVERNMENT HOSPITAL JJ HOSPITAL, MUMBAI Dr. Hemant Gupta [Associate Prof. & Unit Head, Dept of Medicine, J.J.Hospital, Mumbai] Dr. Ayaz Ahmed [lecturer] Dr. Parag

More information

Fine-tuning of The Dose of Insulin Pump

Fine-tuning of The Dose of Insulin Pump Fine-tuning of The Dose of Insulin Pump The manual does not guarantee specific individual or specific applicability of the environment, there is no express or implied warranties. Contents of this manual

More information

Development of Optimal Kids Insulin Dosing System Formulas for Young Children with Type 1 Diabetes Mellitus

Development of Optimal Kids Insulin Dosing System Formulas for Young Children with Type 1 Diabetes Mellitus DIABETES TECHNOLOGY & THERAPEUTICS Volume 14, Number 5, 2012 ª Mary Ann Liebert, Inc. DOI: 10.1089/dia.2011.0184 Development of Optimal Kids Insulin Dosing System Formulas for Young Children with Type

More information

REPORT INTERPRETATION

REPORT INTERPRETATION REPORT INTERPRETATION: Interpreting ipro Professional Continuous Glucose Monitoring (CGM) Reports and Making Therapy Adjustments TARGET AUDIENCE The audience for this section is physicians, mid-level practitioners,

More information

Case Study: Competitive exercise

Case Study: Competitive exercise Case Study: Competitive exercise 32 year-old cyclist Type 1 diabetes since age 15 Last HbA1 54 No complications and hypo aware On Humalog 8/8/8 and Levemir 15 Complains about significant hypoglycaemia

More information

Blood Glucose Monitoring System. Copyright 2017 Ascensia Diabetes Care Holdings AG. All rights reserved. diabetes.ascensia.com

Blood Glucose Monitoring System. Copyright 2017 Ascensia Diabetes Care Holdings AG. All rights reserved. diabetes.ascensia.com Using with the CONTOUR ΤΜ DIABETES app Always consult with your healthcare provider prior to making changes to treatment, diet or exercise. The feature identifies specific patterns and trends in your blood

More information

Type 1 Diabetes Update Robin Goland, MD

Type 1 Diabetes Update Robin Goland, MD Naomi Berrie Diabetes Center Type 1 Diabetes Update 2008 Robin Goland, MD Type 1 diabetes is: A manageable condition A chronic condition Often challenging Entirely compatible with a happy and healthy childhood

More information

Timely!Insulinization In!Type!2! Diabetes,!When!and!How

Timely!Insulinization In!Type!2! Diabetes,!When!and!How Timely!Insulinization In!Type!2! Diabetes,!When!and!How, FACP, FACE, CDE Professor of Internal Medicine UT Southwestern Medical Center Dallas, Texas Current Control and Targets 1 Treatment Guidelines for

More information

Continuous Glucose Monitoring (CGM)

Continuous Glucose Monitoring (CGM) Continuous Glucose Monitoring (CGM) Background Info A1c Average glucose levels over previous 2-3 months Currently remains gold standard for determining control Indicator of risk for development of complications

More information

Insulin Prior Authorization with optional Quantity Limit Program Summary

Insulin Prior Authorization with optional Quantity Limit Program Summary Insulin Prior Authorization with optional Quantity Limit Program Summary 1-13,16-19, 20 FDA LABELED INDICATIONS Rapid-Acting Insulins Humalog (insulin lispro) NovoLog (insulin aspart) Apidra (insulin glulisine)

More information

WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION

WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION 1,2 MINIMED 640G WITH SMARTGUARD HAVE YOU CONSIDERED THE REAL IMPACT HYPOGLYCAEMIA HAS ON YOUR LIFE?

More information

Providing Stability to an Unstable Disease

Providing Stability to an Unstable Disease Basal Insulin Therapy Providing Stability to an Unstable Disease Thomas A. Hughes, M.D. Professor of Medicine - Retired Division of Endocrinology, Metabolism, and Diabetes University of Tennessee Health

More information

1. Continuous Glucose Monitoring

1. Continuous Glucose Monitoring 1. Continuous Glucose Monitoring 1. Physiology of interstitial fluid glucose 2. Comparison of CGM and self-monitored blood glucose (SMBG) data 3. Insulin dosing indication in BGM vs. CGM & the FDA 4. Protection

More information

Mixed Insulins Pick Me

Mixed Insulins Pick Me Mixed Insulins Pick Me Alvin Goo, PharmD Clinical Associate Professor University of Washington School of Pharmacy and Department of Family Medicine Objectives Critically evaluate the evidence comparing

More information

CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER

CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER Case 1: CGM use during pregnancy 29 yo G1P0000 at 10 5/7 weeks gestation presents to set

More information

Blood glucose Meter Roche USA V6/ PMS 287 Proof Print Number 209 Advanced Owner s Booklet

Blood glucose Meter Roche USA V6/ PMS 287 Proof Print Number 209 Advanced Owner s Booklet This file may not print or view at 100%. Die lines and color breaks do not print. Roche USA 50841 V6/1 06434258002 Black Proof Print Number 209 06434258002-0512 Roche USA 50841 V6/2 06434258002 Cyan Proof

More information

Akio Ohta, Kaori Arai, Ami Nishine, Yoshiyuki Sada, Hiroyuki Kato, Hisashi Fukuda, Shiko Asai, Yoshio Nagai, Takuyuki Katabami and Yasushi Tanaka

Akio Ohta, Kaori Arai, Ami Nishine, Yoshiyuki Sada, Hiroyuki Kato, Hisashi Fukuda, Shiko Asai, Yoshio Nagai, Takuyuki Katabami and Yasushi Tanaka Endocrine Journal 2013, 60 (2), 173-177 Or i g i n a l Comparison of daily glucose excursion by continuous glucose monitoring between type 2 diabetic patients receiving preprandial insulin aspart or postprandial

More information

Diabetes Care Publish Ahead of Print, published online June 1, 2009

Diabetes Care Publish Ahead of Print, published online June 1, 2009 Diabetes Care Publish Ahead of Print, published online June 1, 2009 Biphasic insulin aspart 30/70 (BIAsp 30): pharmacokinetics (PK) and pharmacodynamics (PD) in comparison with once-daily biphasic human

More information

10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:

10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD: DEXCOM G5 MOBILE CGM COMPATIBLE B 100% 235 u INSULIN ON BOARD: OPTIONS 10:20 AM March 5, 2017 400 350 300 250 200 150 100 50 1.1 u 1:09 hrs BOLUS 124 mg/dl 3 HRS The pump that gets updated, not outdated.

More information

Pump Failure Guidelines

Pump Failure Guidelines Pump Failure Guidelines Planning Ahead All technology, including pumps, can fail occasionally, even within their warranty period. It is important to be able to independently initiate injection treatment

More information

SCHOOL HEALTH PLAN: DIABETES

SCHOOL HEALTH PLAN: DIABETES BRANDON FLORENCE MCLAURIN NORTHWEST PELAHATCHIE RANKIN COUNTY SCHOOL DISTRICT GREAT TO BEST PISGAH PUCKETT RICHLAND RANKIN COUNTY SCHOOL DISTRICT SCHOOL HEALTH PLAN: DIABETES of Plan: Effective s: This

More information

Stroke Hyperglycemia Insulin Network Effort (SHINE) Trial Treatment Protocols. Askiel Bruno, MD, MS Protocol PI

Stroke Hyperglycemia Insulin Network Effort (SHINE) Trial Treatment Protocols. Askiel Bruno, MD, MS Protocol PI Stroke Hyperglycemia Insulin Network Effort (SHINE) Trial Treatment Protocols Askiel Bruno, MD, MS Protocol PI SHINE Synopsis Acute ischemic stroke

More information

V-Go : Simple to start, easy to use

V-Go : Simple to start, easy to use V-Go : Simple to start, easy to use Patient Start Guide Make multiple daily insulin shots a thing of the past. Take control with V-Go. V-Go Customer Care personalized 1-on-1 support for you Call 1-866-881-1209

More information

Background: Brief review of epidemiology, diagnosis, classification and pathophysiology of diabetes mellistus.

Background: Brief review of epidemiology, diagnosis, classification and pathophysiology of diabetes mellistus. Insulin Therapy in Diabetes Mellitus Part 1 Lekshmi T. Nair, MD, MHS Assistant Professor Department of Internal Medicine Division of Endocrinology, Diabetes and Metabolism The Ohio State University Wexner

More information

How I use the latest technology to investigate and treat a person with Type 1 Diabetes. Dr Pratik Choudhary

How I use the latest technology to investigate and treat a person with Type 1 Diabetes. Dr Pratik Choudhary How I use the latest technology to investigate and treat a person with Type 1 Diabetes Dr Pratik Choudhary Disclosures Advisory board and speaker fees from Medtronic, Roche, Abbott and Johnson and Johnson,

More information

TYPE 1 DIABETES AND EXERCISE. Mark W Savage

TYPE 1 DIABETES AND EXERCISE. Mark W Savage TYPE 1 DIABETES AND EXERCISE Mark W Savage Acknowledgments Slides with a blue background are cropped and courtesy of both Eli Lilly and Company, and Dr Ian Gallen FRCP Consultant Diabetologist, Royal Berkshire

More information

Basal Bolus Insulin Therapy Frequently Asked Questions

Basal Bolus Insulin Therapy Frequently Asked Questions 1. What is Basal Bolus Insulin Therapy (BBIT)? 2. What evidence supports the use of subcutaneous Basal Bolus Insulin Therapy? 3. Does Basal Bolus Insulin Therapy apply to all patients? 4. What s wrong

More information

BEDFORDSHIRE AND LUTON JOINT PRESCRIBING COMMITTEE (JPC)

BEDFORDSHIRE AND LUTON JOINT PRESCRIBING COMMITTEE (JPC) BEDFORDSHIRE AND LUTON JOINT PRESCRIBING COMMITTEE (JPC) June 2017 Review: June 2020 (earlier if required see recommendations) Bulletin 255: Insulin aspart New Formulation - Fiasp JPC Recommendations:

More information

Optimizing Therapy and Clinical Outcomes Using Real-Time Continuous Glucose Monitoring (AADE PRODUCT THEATRE) August 7, 2014 Orlando, FL

Optimizing Therapy and Clinical Outcomes Using Real-Time Continuous Glucose Monitoring (AADE PRODUCT THEATRE) August 7, 2014 Orlando, FL Optimizing Therapy and Clinical Outcomes Using Real-Time Continuous Glucose Monitoring (AADE PRODUCT THEATRE) August 7, 2014 Orlando, FL Welcome and Introduction Orlando, FL August 7 th, 2014 Keri Weindel,

More information

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness Prepared for: Agency for Healthcare Research and Quality (AHRQ) www.ahrq.gov Outline of Material Introduction

More information

DISCOVER THE POWER OF CONNECTION MINIMED 640G

DISCOVER THE POWER OF CONNECTION MINIMED 640G DISCOVER THE POWER OF CONNECTION MINIMED 640G INSULIN PUMP THERAPY CHANGING LIVES TODAY Have you just been diagnosed with insulin dependent diabetes? Perhaps you ve been on multiple daily injection therapy

More information

The York Diabetes Care Model

The York Diabetes Care Model This Session The York Diabetes Care Model The annual review what s it for and how to do it How to make the diagnosis of diabetes and who to test Categorisation of diabetes at diagnosis Basics of Insulin

More information

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018 Objectives Innovations in Diabetes Care and Management Barbara Walz, RN, BSN, CDE April 26, 2018 1. Briefly discuss the history of diabetes management over the past 100 years 2. Describe the impact of

More information

These results are supplied for informational purposes only.

These results are supplied for informational purposes only. These results are supplied for informational purposes only. Prescribing decisions should be made based on the approved package insert in the country of prescription Sponsor/company: sanofi-aventis ClinialTrials.gov

More information

Updates in Diabetes Technology

Updates in Diabetes Technology Updates in Diabetes Technology Jessica Kirk, MSN, RN, CPN, CDE Nurse Manager, Endo ECHO No disclosures Disclosures 1 Objectives Distinguish patients appropriate for continuous glucose monitoring and insulin

More information

Do fat and protein affect post prandial glycemia in the outpatient real world setting? Neha Verma, MD Robert Melfi, MD

Do fat and protein affect post prandial glycemia in the outpatient real world setting? Neha Verma, MD Robert Melfi, MD Do fat and protein affect post prandial glycemia in the outpatient real world setting? Neha Verma, MD Robert Melfi, MD Objectives Understand the effect of fat and protein on glycemic excursion in the post-prandial

More information

Insulin Pumps Available in Canada

Insulin Pumps Available in Canada Insulin Pumps Available in Canada A Comparison from WaltzingTheDragon.ca *Accu-Chek Animas Ping/Vibe Medtronic Minimed 630G Omnipod ABOUT FORM: Is the insulin pump Tubing- Free? Is the pump? Or Water-Resistant?

More information