Dye dilution method. densitometry Fox 1761 Haller. = I / D 60 (L/min) Hamilton Stewart. Bloomfield 2) ( ) pulse dye
|
|
- Eustace Daniels
- 5 years ago
- Views:
Transcription
1 Dye dilution method 1. D(secmg/L) I(mg) CO = I / D 60 (L/min) 2 1) Bloomfield 2) ( ) pulse dye 1 densitometry Fox 1761 Haller 3) Stewart 4) Kinsman Hamilton Stewart 5) 1
2 52 Dye dilution method 2 Kinsman, Hamilton Kinsman et al: Amer J Physiol, 1929, 5) 2 I B D 1948 Hamilton Evans blue Fick 6) Hamilton Millikan oximeter Wood Oximetry, Medical Physics Vol2, ) CO 1950 Wood oximeter 2.2 Millikan oximeter Wood oximeter oximeter dye densitometer Densitometer Millikan oximeter Wood oximeter Millikan ear oximeter 4
3 green filter I red filter R Wood 7) nm Millikan green filter 750 nm 600 nm 800 nm red filter nm RHb O 2 Hb Millikan oximeter Wood 5 5 A C Io In Lambert-Beer A A R = A IR = log Io R In R = E R Hb D (1) log Io IR In IR = E IR Hb D (2) R IR E Hb D (1) (2) 5 Wood oximeter Wood et al J Lab Clin Med ) 6 Wood SaO 2 Wood et al: J Lab Clin Med, ) = A R A IR = E R E IR (3) E Wood 5 white subject 5 dark subject 6 8) 2.4 Wood densitometer Wood oximeter densitometer Wood densitometer pulse oxmetory ( 7) Wood oximeter O 2 Hb RHb
4 54 Dye dilution method 7 Wood densitometer Hb 4 5 Hb A 8 Evans blue, ICG, O 2 Hb, RHb A 1 = log Io 1 In 1 = Eh 1 Hb D + Ed 1 Cd D (4) A 2 = log Io 2 In 2 = Eh 2 Hb D + Ed 2 Cd D (5) Io In nm nm Eh Ed ICG Hb Cd ICG D ICG nm ICG Ed 2 =0 (5) A 2 = log Io 2 In 2 = Eh 2 Hb D (6) (4) (6) = A 1 A 2 = E h1 E h2 + Ed 1 Ed 2 Cd Hb (7) E Hb Cd 2.5 Indocyanine green ICG Stewart, Hamilton Evans 9 Evans blue ICG Fox et al: Proc Staff Meet Mayo Clin, ) blue Evans blue 625 nm Evans blue 1956 Fox ICG 9) ICG Evans blue O 2 Hb RHb 8 ICG 805 nm 805 nm O 2 Hb RHb SO 2 9 Evans Blue ICG 2 right ventricle Evans blue ICG 10) ICG ICG angiography
5 ICG Obana et al: Am J Ophthalmol, (11) Obana ICG angiography ICG 11) ICG test 3774 ICG mg 2 ( 2) ICG 2.6 pulse oximetry pulse oximetry ) pulse oximetry Wood densitometer Wood densitometer 10 densitometer (1) a. b. (7) 2 Wood densitometer pulse oximetry pulse oximetry 10 :, 1966.(1) 3 Wood oximeter pulse oximeter Wood oximetry Wood oximetry D pulse oximetry D Wood oximetry pulse oximetry systolic phase Is diastolic phase Id Lambert-Beer A R = A IR = = log Id R Is R = E R Hb D (8) log Id IR = E IR Hb D (9) Is IR A R = E R (10) A IR E IR (10) SaO 2 SaO 2
6 56 Dye dilution method 11 pulse dye densitometry pulse oximetry Wood oximetry pulse dye densitometry 1974 pulse oximetry pulse dye densitometry (PDD) PDD pulse oximetry pulse spectrophotometry Pulse oximeter O 2 Hb RHb PDD Hb 13,14,15) pulse dye densitometer Wood Hb PDD Pulse oximeter Wood PDD Wood 11 1 early phase 12 Iijima T et al: J Anesth, 2005[16] 6 late phase PDD PDD ICU 16) [1]
7 ) 2) 1) Stewart Hamilton Wood oximetry Aoyagi pulse oximetry 2) Wood oximeter Wood method dye densitometer ICG Pulse oximeter Pulse dye densitometer Wood dye densitometer Pulse oximetory Pulse oximeter 1997 Pulse dye densitometer 1. :,, Bloomfield DA; Dye Curves: The theory and practice of indicator dilution., HM + M, Fox IJ: History and development aspects of the indicator-dilution technic. Circul Res 10:381, Stewart MA: Research on the circulation time in organs and on the influences which affect it. I. Preliminary paper. Proc. Physiol.Soc.Nov.8th, Kinsman JM, Moore JW, Hamilton WF: Studies on the circuration. Injection method: Physical and mathematical considerations. Amer.J.Physiol. 89: , Hamilton WF, Riley RL, et al.: Comparison of the Fick and dye injection methods of measuring the cardiac output in man., Am J Physiol. 1;153: , Wood EH: Oximetry, Medical Physics Vol2, , The Year Book Publishers Inc Wood EH, Geraci JE: Photoelectric determination of arterial oxygen saturation in man. J Lab Clin Med., 34: , Fox IJ,Brooker LGS, Heseltine DW, Wood EH: A new dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation., Circulation 14, 937-8, Abstracts of the 29th scientific session, Fox IJ, Wood EH: Applications of dilution curves recorded from the right side of the heart or venous circulation with the aid of a new indicator dye. Proc Staff Meet Mayo Clin. 18;32:541-50, Obana A, Miki T, Hayashi K. et al., Survey of complications of indocyanine green angiography in Japan., Am J Ophthalmol. Dec 15;118: ME, 90-1, M.Fuse, T.Aoyagi, M.Kanemoto, C.Xie, H.Hosaka, M.Katayama, K.Miyasaka Dye dilution curve measurement using the principle of pulse oximetry. Medical and Biological Engineering & Computing 29 Suppl. 853, Iijima T, Aoyagi T, Iwao Y, Masuda J, Fuse
8 58 Dye dilution method M, Kobayashi N, Sankawa H: Cardiac output and circulating blood volume analysis by pulse dye-densitometry. J Clin Monit, 13:81-9, ?5: , Iijima T, Ueyama H et al: Determination of the standard value of circulating blood volume during anesthesia using pulse dyedensitometry: a multicenter study in Japan. J Anesth. 19:
A Simplified Method for Calculation of the Left to-right Shunt from a Single Earpiece Dye-dilution Curve
Tohoku J. exp. Med., 1969, 97, 337-346 A Simplified Method for Calculation of the Left to-right Shunt from a Single Earpiece Dye-dilution Curve Tetsuo Sato, Hiroshi Onoki, Norio Yamauchi and Ichiki Kano
More informationBiomedical Instrumentation D. The Photoplethysmogram
Biomedical Instrumentation D. The Photoplethysmogram Dr Gari Clifford Based on slides by Prof. Lionel Tarassenko The need for real-time oxygen saturation monitoring Respiratory failure & pulmonary disease
More informationThis work is licensed under a Creative Commons Attribution-Noncommercial-Share Alike 3.0 License.
University of Massachusetts Medical School escholarship@umms UMass Center for Clinical and Translational Science Research Retreat 2017 UMass Center for Clinical and Translational Science Research Retreat
More informationMeasuring circulating blood volume in newborn infants using pulse dye densitometry and indocyanine green
Pediatric Anesthesia 2008 18: 865 871 doi:10.1111/j.1460-9592.2008.02647.x Measuring circulating blood volume in newborn infants using pulse dye densitometry and indocyanine green NARENDRA ALADANGADY FRCPCH*,
More informationOximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan
Oximeters Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan chanhl@mail.cgu.edu.tw Pulse oximeter Masimo pulse CO-oximeter http://www.masimo.com/produc ts/continuous/radical-7/
More informationCLINICAL INVESTIGATIONS. ACUTE administration of crystalloid solution to parturients
1571 CLINICAL INVESTIGATIONS Anesthesiology 1999; 91:1571 6 1999 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc. Effects of Crystalloid and Colloid Preload on Blood Volume
More informationPulse oximetry revisited. Dr Liesel Bösenberg Specialist Physician and Fellow in Critical Care Kalafong Hospital University of Pretoria
Pulse oximetry revisited Dr Liesel Bösenberg Specialist Physician and Fellow in Critical Care Kalafong Hospital University of Pretoria Topics that will be discussed and dissected: Revisiting physiology
More informationNoninvasive Evaluation of Cardiac Output during Postural Change and Exercise in Humans: Comparison between the Modelflow and Pulse Dye-Densitometry
Japanese Journal of Physiology, 54, 153 160, 2004 Noninvasive Evaluation of Cardiac Output during Postural Change and Exercise in Humans: Comparison between the Modelflow and Pulse Dye-Densitometry K.
More informationSLOPE-VOLUME METHOD AS AN INDEX OF PULMONARY BLOOD VOLUME* tion of the blood flow and the rate of diminishing
EVALUATION OF THE SLOPE-VOLUME METHOD AS AN INDEX OF PULMONARY BLOOD VOLUME* By YANG WANG,t JOHN T. SHEPHERD 4 AND ROBERT J. MARSHALL (From the Mayo Clinic and Mayo Foundation,II Rochester, Minn.) (Submitted
More informationOximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan
Oximeters Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan chanhl@mail.cgu.edu.tw Oxygen transport in blood Hemoglobin Oxygen O Deoxygen +O O Oximeters Arterial saturation
More informationTHE RELATION BETWEEN CARDIAC OUTPUT AND BODY SIZE*
Brit. Heart J., 1963, 25, 425. TH RLATION BTWN CARDIAC OUTPUT AND BODY SIZ* BY W. JGIR, PAUL SKLJ, P. A. M. AULD, R. SIMPSON, AND M. McGRGOR From the Joint Cardio-Respiratory Service of the Montreal Children's
More informationSERIAL DETERMINATIONS BY A DYE DILUTION METHOD
THE NORMAL RESTING CARDIAC OUTPUT: SERIAL DETERMINATIONS BY A DYE DILUTION METHOD BY THOMAS A. BRUCE* AND JOHN P. SHILLINGFORD From the Department of Medicine, and the Medical Research Council Research
More informationUniversity of Groningen
University of Groningen Registratie en kwantitatieve interpretatie van kleurstofverdunningscurves, verkregen door reflectiemeting in rood of infrarood licht. Sparling, Cornelis Martinus IMPORTANT NOTE:
More informationBOTH ATEOPINE and isoproterenol
Effects of tropine and Isoproterenol on Cardiac Output, Central Venous Pressure, and Transit Time of Indicators Placed at Three Different Sites in the Venous System y KLPH RTEX, M.D., J. CULIE GUNXELLS,
More informationQUIZ 1. Tuesday, March 2, 2004
Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments
More informationsalt-free dextran. Increase in cardiac output was Evans Blue Dye. generally observed following hypervolemia.
FURTHER OBSERVATONS ON THE HEMODYNAMC EFFECT OF PLASMA VOLUME EXPANSON BY DEXTRAN1 By J. W. FLEMNG AND W. L. BLOOM (From the Piedmont Hospital, Atlanta, Ga., and the Medical Research Laboratory, Veterans
More informationCARDIOVASCULAR MONITORING. Prof. Yasser Mostafa Kadah
CARDIOVASCULAR MONITORING Prof. Yasser Mostafa Kadah Introduction Cardiovascular monitoring covers monitoring of heart and circulatory functions It makes it possible to commence interventions quickly in
More informationRevision of 10/27/2017 Form #280 Page 1 of 12 PVDOMICS STUDY Clinical Center Right Heart Catheterization (RHC) Results Form #280
Revision of 10/27/2017 Form #280 Page 1 of 12 PVDOMICS STUDY Clinical Center Right Heart Catheterization (RHC) Results Form #280 Instructions: Review PVDOMICS MOP Chapter 100 prior to completing right
More informationISSN: [Cortes* et al., 7(3): March, 2018] Impact Factor: 5.164
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY DESING OF A HYPOXIA DEVICE DETECTOR WITH WIRELESS ALERT Ing. Teo Cortes *1 & Dra. Fatima Moumtadi *2 *Department of Electronics,
More informationDetermination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times
Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times Clarence M. AGRESS, M.D. and Stanley WEGNER SUMMARY Examination was made of the relationship of left ventricular
More informationChandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology
Should NIRS be Standard Care for Pediatric CPB Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University Director of Pediatric Cardiac Anesthesiology Stanford Children s Hospital
More informationHow Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve
SpO2 Monitoring Contents 1 Introduction 1 What is SpO 2? How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve 5 How Do I Use SpO2? Choosing a Sensor
More informationCARDIOVASCULAR STUDIES
THE TWO-CATHETER TECHNIQUE IN INDICATOR-DILUTION CARDIOVASCULAR STUDIES BY E. GREY DIMOND, ALBERTO BENCHIMOL, AND ERNEST W. CROW From The Institute for Cardio-pulmonary Diseases, Scripps Clinic and Research
More informationNoninvasive Detection of Bilirubin in Discrete Vessels
, July 2-4, 2014, London, U.K. Noninvasive Detection of Bilirubin in Discrete Vessels Mark McEwen, Karen J. Reynolds Abstract Bilirubin, at the levels encountered in hyperbilirubinaemia, makes a similar
More informationThe patients were studied in the fasting state. All. were male, and their ages ranged from 22 to 44. Diagnoses
THE EFFECT OF THE INTRAVENOUS ADMINISTRATION OF DEXTRAN ON CARDIAC OUTPUT AND OTHER CIR- CULATORY DYNAMICS 1 By A. C. WITHAM, J. W. FLEMING, AND W. L. BLOOM (From the Medical Service, Lawson VA Hospital,
More informationTHE increase in cardiac output during
Effects of Cateeholamines and Atropine on Cardiovascular Response to Exercise in the Dog By ERNST W. 0. KECK, M.D., MICHAEL J. ALLWOOD, M.B., PH.D., ROBERT J. MARSHALL, M.D., M.R.C.P., AND JOHN T. SHEPHERD,
More informationResearch Journal of Pharmaceutical, Biological and Chemical Sciences
Research Journal of Pharmaceutical, Biological and Chemical Sciences Oxygen Glucose and Heart rate Monitor: An non Invasive approach Anne Frank Joe A*, Veeramani Saikrupa, and Prajukti Panda Sathyabama
More informationPermanent City Research Online URL:
Kyriacou, P. A., Pal, S. K., Langford, R. & Jones, DP (2006). Electro-optical techniques for the investigation of oesophageal photoplethysmographic signals and blood oxygen saturation in burns. Measurement
More informationCARDIAC OUTPUT Monitoring ANDY CAMPBELL JOURNAL CLUB NOV 2011
CARDIAC OUTPUT Monitoring ANDY CAMPBELL JOURNAL CLUB NOV 2011 Is keeping up the pressure enough? It is a source of regret that the measurement of flow is so much more difficult than the measurement of
More informationDesign and Development of Non-Invasive Prototype to Measure Pulse Rate, Blood Glucose and Oxygen Saturation Level in Arterial Blood
Design and Development of Non-Invasive Prototype to Measure Pulse Rate, Blood Glucose and Oxygen Saturation Level in Arterial Blood Nazo Haroon Department of Mechatronics Engineering, CEME National University
More informationJournal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE
PAK BULLET TRAIN (PBT) JFET 22(2) (2015) 39-44 Journal of Faculty of Engineering & Technology journal homepage: www.pu.edu.pk/journals/index.php/jfet/index DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH
More informationOxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood
Oxygen Saturation Monitors & Pulse Oximetry D. J. McMahon 141105 rev cewood 2017-11-14 2 3 Key Points Oxygen Saturation Monitors & Pulse Oximetry : Role of hemoglobin in respiration Basic principle of
More informationDRAINAGE PATHWAYS OF PULMONARY VEINS IN ATRIAL SEPTAL DEFECT
DRAINAGE PATHWAYS OF PULMONARY VEINS IN ATRIAL SEPTAL DEFECT BY EUGENE BRAUNWALD, CARLOS R. LOMBARDO, AND ANDREW G. MORROW From the Clinic of Surgery, National Heart Institute, Bethesda, Maryland, U.S.A.
More informationORIGINAL RESEARCH. Effect of road traffic accident contaminants on pulse oximetry among normoxaemic volunteers
ISSN 1447-4999 ORIGINAL RESEARCH Effect of road traffic accident contaminants on pulse oximetry among normoxaemic volunteers Dr Gyorgyi Kamaras MD, FCEM 1,2, Dr Tamas Geller MD 1, Dr Csaba Dioszeghy MD
More informationWhat is. InSpectra StO 2?
What is InSpectra StO 2? www.htibiomeasurement.com What is InSpectra StO 2? Hemoglobin O 2 saturation is measured in three areas: 1) Arterial (SaO 2, SpO 2 ) Assesses how well oxygen is loading onto hemoglobin
More informationABSTRACT. Recent studies have shown that the photoplethysmogram
A preliminary study of respiratory variations in the photoplethysmogram during lower body negative pressure Suzanne Wendelken, Stephen Linder, Sue McGrath Thayer School of Engineering and the Institute
More informationHaemodynamics. Milan Chovanec Department of Physiology 2.LF UK
Haemodynamics Milan Chovanec Department of Physiology 2.LF UK Major types of blood vessels Blood flow: 50cm/s 0.05cm/s Flow, pressure, resistance Flow, pressure, resistance ΔU = I x R Blood and vessels
More informationWhen Cyanosis is the Norm. Steven M. Schwartz, MD, FRCPC Cardiac Critical Care Medicine The Hospital for Sick Children Toronto
When Cyanosis is the Norm Steven M. Schwartz, MD, FRCPC Cardiac Critical Care Medicine The Hospital for Sick Children Toronto No Disclosures When Cyanosis is the Norm Physiology of cyanotic congenital
More informationContent Display. - Introduction to Unit 4. Unit 4 - Cardiorespiratory Response to Exercise : Lesson 1. KINE xxxx Exercise Physiology
Content Display Unit 4 - Cardiorespiratory Response to Exercise : Lesson KINE xxxx Exercise Physiology 5 Unit 4 - Cardiorespiratory Response to Exercise Lesson U4LP - Introduction to Unit 4 The specific
More informationNon-invasive Hemoglobin Measurement for Anemia Diagnosis
Non-invasive Hemoglobin Measurement for Anemia Diagnosis Raditya Artha Rochmanto 1, Hasballah Zakaria 2 Ratih Devi Alviana 3, Nurhalim Shahib 4 Department of Biomedical Engineering Medical Faculty Institut
More informationCheck a Pulse! When to Question SpO 2, NIBP & EtCO 2 Readings
Check a Pulse! When to Question SpO 2, NIBP & EtCO 2 Readings Mike McEvoy, PhD, RN, CCRN, NRP Professor Emeritus - Critical Care Medicine Albany Medical College Albany, New York Chair Resuscitation Committee
More informationONLINE DATA SUPPLEMENT. Impact of Obstructive Sleep Apnea on Left Ventricular Mass and. Diastolic Function
ONLINE DATA SUPPLEMENT Impact of Obstructive Sleep Apnea on Left Ventricular Mass and Diastolic Function Mitra Niroumand Raffael Kuperstein Zion Sasson Patrick J. Hanly St. Michael s Hospital University
More informationCalculations the Cardiac Cath Lab. Thank You to: Lynn Jones RN, RCIS, FSICP Jeff Davis RCIS, FSICP Wes Todd, RCIS CardioVillage.
Calculations the Cardiac Cath Lab Thank You to: Lynn Jones RN, RCIS, FSICP Jeff Davis RCIS, FSICP Wes Todd, RCIS CardioVillage.com Disclosure Information Calculations the Cardiac Cath Lab Darren Powell,
More informationInternational Journal of Health Sciences and Research ISSN:
International Journal of Health Sciences and Research www.ijhsr.org ISSN: 2249-9571 Review Article Pulse Oximetry - Working Principles in Pulpal Vitality Testing Jayashankar DN 1@, Zakirulla M 2, Sudhakar
More informationSupplementary Online Content
Supplementary Online Content Schmidt B, Whyte RK, Asztalos EV, et al; for the Canadian Oxygen Trial (COT) Group. Effects of targeting higher vs lower arterial oxygen saturations on death or disability
More informationanid to add new studies to fill in the gap between
BEHAVIOR OF STROKE VOLUME AT REST AND DURING EXERCISE IN HUMAN BEINGS * By CARLETON B. CHAPMAN, JOSEPH N. FISHER AND BRIAN J. SPROULE (Fromn the Cardiopulmoniary Laboratory of the Departmient of Intterntal
More informationBrief View of Calculation and Measurement of Cardiac Hemodynamics
Cronicon OPEN ACCESS EC CARDIOLOGY Review Article Brief View of Calculation and Measurement of Cardiac Hemodynamics Samah Alasrawi* Pediatric Cardiologist, Al Jalila Children Heart Center, Dubai, UAE *
More informationConsumer Near Infrared Spectroscopy as a Training and Recovery Tool. Jon Tarkington
Consumer Near Infrared Spectroscopy as a Training and Recovery Tool Jon Tarkington Outline - What is NIRS? - Devices - Data interpretation - Practical Application - Future Impacts - Suffix light Disclaimers
More informationFOWLER AND COWORKERS have
Effect of 1Arterenol Infusion on "Central Blood Volume" in the Dog By OSCAR W. SHADLB, M.D., JAMES C. MOORE, M.D. AND DOAL M. BILLIG, A.B. Infusion of 1arterenol into anesthetized dogs increased the volume
More informationAdvanced Monitoring of Cardiovascular and Respiratory Systems in Infants Kuwait 2018 Dr. Yasser Elsayed, MD, PhD Director of the Targeted Neonatal
Advanced Monitoring of Cardiovascular and Respiratory Systems in Infants Kuwait 2018 Dr. Yasser Elsayed, MD, PhD Director of the Targeted Neonatal Echocardiography, Point of Care and Hemodynamics Program
More informationCHAPTER 21 PULSE OXIMETRY AND PLETHYSMOGRAPHY
CHAPTER 21 PULSE OXIMETRY AND PLETHYSMOGRAPHY JOHANNES H. VAN OOSTROM BRIAN FUEHRLEIN RICHARD J. MELKER Pulse oximetry is a standard of care and is ubiquitous in operating rooms, inpatient hospital wards,
More informationCardiac output and Venous Return. Faisal I. Mohammed, MD, PhD
Cardiac output and Venous Return Faisal I. Mohammed, MD, PhD 1 Objectives Define cardiac output and venous return Describe the methods of measurement of CO Outline the factors that regulate cardiac output
More informationCARDIAC OUTPUT,VENOUS RETURN AND THEIR REGULATION. DR.HAROON RASHID. OBJECTIVES
CARDIAC OUTPUT,VENOUS RETURN AND THEIR REGULATION. DR.HAROON RASHID. OBJECTIVES Define Stroke volume, Cardiac output Venous return,& identity their normal values. Describe control (intrinsic & extrinsic)
More informationfluid in the muscles of the rat and the frog following violent
612.766.1: 612.014.461.3 THE CHANGES IN PLASMA AND TISSUE FLUID VOLUME FOLLOWING EXERCISE. By H. CULLUMBINE and A. C. E. KoCH. From the Department of Physiology and Pharmacology, University of Ceylon,
More informationImpedance Cardiography (ICG) Method, Technology and Validity
Method, Technology and Validity Hemodynamic Basics Cardiovascular System Cardiac Output (CO) Mean arterial pressure (MAP) Variable resistance (SVR) Aortic valve Left ventricle Elastic arteries / Aorta
More informationPulsioFlex Patient focused flexibility
PulsioFlex Patient focused flexibility Modular platform with intelligent visualisation for advanced patient Minimally invasive perioperative cardiac output trend with ProAQT Enables calibrated cardiac
More informationSCVMC RESPIRATORY CARE PROCEDURE
Page 1 of 7 New: 12/08 R: 4/11 R NC: 7/11, 7/12 B7180-63 Definitions: Inhaled nitric oxide (i) is a medical gas with selective pulmonary vasodilator properties. Vaso-reactivity is the evidence of acute
More informationOximetric detection of intracardiac left-to-right shunts'
British Heart Journal, 1979, 42, 690-694 Oximetric detection of intracardiac left-to-right shunts' MICHAEL D. FREED, OLLI S. MIETTINEN, AND ALEXANDER S. NADAS From the Department of Cardiology, Children's
More informationLab 16. The Cardiovascular System Heart and Blood Vessels. Laboratory Objectives
Lab 16 The Cardiovascular System Heart and Blood Vessels Laboratory Objectives Describe the anatomical structures of the heart to include the pericardium, chambers, valves, and major vessels. Describe
More informationHemodynamic Monitoring
Perform Procedure And Interpret Results Hemodynamic Monitoring Tracheal Tube Cuff Pressure Dean R. Hess PhD RRT FAARC Hemodynamic Monitoring Cardiac Rate and Rhythm Arterial Blood Pressure Central Venous
More informationYuko Kondo, Kaoru Sakatani, Noriya Hirose, Takeshi Maeda, Jitsu Kato, Setsuro Ogawa, and Yoichi Katayama
Chapter 16 Effect of Spinal Anesthesia for Elective Cesarean Section on Cerebral Blood Oxygenation Changes: Comparison of Hyperbaric and Isobaric Bupivacaine Yuko Kondo, Kaoru Sakatani, Noriya Hirose,
More informationCorrelation of Ratio of Ratio of Near Infrared Vs Infrared Photoplethysmograph Spectroscopy for the Non-Invasive Measurement of Haemoglobin
Correlation of Ratio of Ratio of Near Infrared Vs Infrared Photoplethysmograph Spectroscopy for the Non-Invasive Measurement of Haemoglobin Ashita Diwate 1, Yogesh Kumar 2, Dr. Sanjeev Kumar 3, Prof. T.
More informationPROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004
Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments
More informationIs Hypoxia common despite oxygen treatment in the Acute Medical ward?
Is Hypoxia common despite oxygen treatment in the Acute Medical ward? Dr. R Dhar, Dr. RN Harrison and Dr. PD Snashall University Hospital of North Tees, Stockton on Tees, TS198PE, United Kingdom (Received
More informationIndications and Usage: For determining cardiac output, hepatic function and liver blood flow, and for ophthalmic angiography.
INDOCYANINE GREEN - INDOCYANINE GREEN - indocyanine green injection, powder, lyophilized, for solution Novadaq Technologies Inc. ---------- Indocyanine Green for Injection USP Rx Only Description: Indocyanine
More informationGlobal Pulse Oximetry Market: Trends and Opportunities ( )
Global Pulse Oximetry Market: Trends and Opportunities (2013-18) Scope of the Report The report titled Global Pulse Oximetry Market: Trends and Opportunities (2013-2018) provides an insight into the market
More informationThe Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for
1 2 The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for continuous central venous oximetry (ScvO2) 3 The Vigileo
More informationInfrared fundus angiography
Brit. J. Ophthal. (I973) 57, 797 Infrared fundus angiography NICHOLAS BROWN AND RICHARD STRONGC Moorfields Eye Hospital, City Road, London This paper describes a technique for fundus angiography of the
More informationHemodynamic Monitoring in Critically ill Patients in Arthur Simonnet, interne Tuteur : Pr. Raphaël Favory
Hemodynamic Monitoring in Critically ill Patients in 2017 Arthur Simonnet, interne Tuteur : Pr. Raphaël Favory Rationale for Hemodynamic Monitoring Identify the presence of hemodynamic instability Identify
More informationMeasuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices
Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices By Zhang Feng, Senior Medical Applications Engineer Marten Smith, Medical Marketing Manager Medical Products Group Microchip
More informationPerioperative Goal- Protocol Summary
Perioperative Goal- Directed Therapy Protocol Summary Evidence-based, perioperative Goal-Directed Therapy (GDT) protocols. Several single centre randomized controlled trials, meta-analysis and quality
More informationPulse Dye Densitometry and Indocyanine Green Plasma Disappearance in ASA Physical Status I-II patients
Pulse Dye Densitometry and Indocyanine Green Plasma Disappearance in ASA Physical Status I-II patients Marije Reekers, Mischa J.G. Simon, Fred Boer, René A.G. Mooren Jack W. van Kleef, Albert Dahan and
More informationPerioperative Goal- Protocol Summary
Perioperative Goal- Directed Therapy Protocol Summary Evidence-based, perioperative Goal-Directed Therapy (GDT) protocols. Several single centre randomized controlled trials, meta-analysis and quality
More informationAppendix E Choose the sign or symptom that best indicates severe respiratory distress.
Appendix E-2 1. In Kansas EMT-B may monitor pulse oximetry: a. after they complete the EMT-B course b. when the service purchases the state approved pulse oximeters c. when the service director receives
More informationPCV and PAOP Old habits die hard!
PCV and PAOP Old habits die hard! F Javier Belda MD, PhD Head of Department Associate Professor Anaesthesia and Critical Care Hospital Clínico Universitario Valencia (SPAIN) An old example TOBACO SMOKING
More informationMASSACHUSETTS INSTITUTE OF TECHNOLOGY
Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments
More information#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure
#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure Objectives: Observe slide of artery and vein cross-section Auscultate heart sounds using a stethoscope Measure
More informationDefinition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill
By Craig Definition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill pt Can assist diagnosis and decision making
More informationAbsolute Cerebral Oximeters for Cardiovascular Surgical Cases
Absolute Cerebral Oximeters for Cardiovascular Surgical Cases Mary E. Arthur, MD, Associate Professor, Anesthesiology and Perioperative Medicine Medical College of Georgia at Georgia Regents University
More informationDESCRIBE THE FACTORS AFFECTING CARDIAC OUTPUT.
DESCRIBE THE FACTORS AFFECTING CARDIAC OUTPUT. BY: DISHA PRAKASH I MBBS, ROLL NO: 16M069 OBJECTIVES OF LEARNING Terminology and conceptual understanding of Cardiac Output. Factors regulating Cardiac Output.
More informationFUNDAMENTALS OF HEMODYNAMICS, VASOACTIVE DRUGS AND IABP IN THE FAILING HEART
FUNDAMENTALS OF HEMODYNAMICS, VASOACTIVE DRUGS AND IABP IN THE FAILING HEART CINDY BITHER, MSN, ANP, ANP, AACC, CHFN CHIEF NP, ADV HF PROGRAM MEDSTAR WASHINGTON HOSPITAL CENTER CONFLICTS OF INTEREST NONE
More informationOptical Sensor System for Hemoglobin Measurement
International Journal of Computational Engineering Research Vol, 03 Issue, 7 Optical Sensor System for Hemoglobin Measurement Rajashree Doshi 1, Anagha Panditrao 2 1 Department of Instrumentation and Control,
More informationSepsis Wave II Webinar Series. Sepsis Reassessment
Sepsis Wave II Webinar Series Sepsis Reassessment Presenters Nova Panebianco, MD Todd Slesinger, MD Fluid Reassessment in Sepsis Todd L. Slesinger, MD, FACEP, FCCM, FCCP, FAAEM Residency Program Director
More informationCritical Care Monitoring. Assessing the Adequacy of Tissue Oxygenation. Tissue Oxygenation - Step 1. Tissue Oxygenation
Critical Care Monitoring 1 Assessing the Adequacy of Tissue oxygenation is the end-product of many complex steps 2 - Step 1 Oxygen must be made available to alveoli 3 1 - Step 2 Oxygen must cross the alveolarcapillary
More informationPulse Oximetry Test: Summary Report
Test Condition : Overnight on Room Air Pulse Oximetry Test: Summary Report Patient Information Referring/Ordering Physician DME/HME Courier John Sample Insurance ID : 123456789B DOB : 1/1/1909 Gender :
More informationIntroduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring
Introduction Invasive Hemodynamic Monitoring Audis Bethea, Pharm.D. Assistant Professor Therapeutics IV January 21, 2004 Hemodynamic monitoring is necessary to assess and manage shock Information obtained
More informationA New Technique for Repeated Measurement of Cardiac Output During Cardiopulmonary Resuscitation
Purdue University Purdue e-pubs Weldon School of Biomedical Engineering Faculty Publications Weldon School of Biomedical Engineering 1980 A New Technique for Repeated Measurement of Cardiac Output During
More informationGeorgios C. Bompotis Cardiologist, Director of Cardiological Department, Papageorgiou Hospital,
Georgios C. Bompotis Cardiologist, Director of Cardiological Department, Papageorgiou Hospital, Disclosure Statement of Financial Interest I, Georgios Bompotis DO NOT have a financial interest/arrangement
More informationIndicators and Detectors for Circulatory Dilution Studies and Their Application to Organ or Regional Blood-flow Determination
Indicators and Detectors for Circulatory Dilution Studies and Their Application to Organ or Regional Blood-flow Determination By I. j. Fox, M.D. Increasing application of the indicator-dilution technic
More informationCogent 2-in-1 Hemodynamic Monitoring System
Cogent 2-in-1 Hemodynamic Monitoring System Minimally invasive and invasive hemodynamic monitoring technologies in a single, lightweight system with wireless communication The flexibility you ve been asking
More informationsuggested by Katz and Gauchat (3) for the ex- diaphragm during inspiration, traction is applied Dornhorst, Howard, and Leathart (2), using an
Journal of Clinical Investigation Vol. 42, No. 2, 1963 THE MECHANISM OF PULSUS PARADOXUS DURING ACUTE PERICARDIAL TAMPONADE * By RICHARD J. GOLINKO,t NEVILLE KAPLAN, AND ABRAHAM M. RUDOLPH t (From the
More informationMechanics of Cath Lab Support Devices
Mechanics of Cath Lab Support Devices Issam D. Moussa, MD Chief Medical Officer First Coast Cardiovascular Institute, Jacksonville, FL Professor of Medicine, UCF, Orlando, FL None DISCLOSURE Percutaneous
More informationDisclosures. Set up audience participation. Test question. Outline. Neuromonitoring What and When? IP for monitoring technology licensed to Medtronic
Neuromonitoring What and When? Disclosures IP for monitoring technology licensed to Medtronic Ken Brady, MD Pediatrics, Anesthesia, Critical Care Texas Children s Hospital Baylor College of Medicine Set
More informationEvolutionary origins of the right ventricle. S Magder Department of Critical Care, McGill University Health Centre
Evolutionary origins of the right ventricle S Magder Department of Critical Care, McGill University Health Centre Fully separated four chamber heart only evolved in birds and mammals What are the evolutionary
More informationSTUDIES OF THE PULMONARY AND SYSTEMIC ARTERIAL
STUDIES OF THE PULMONARY AND SYSTEMIC ARTERIAL PRESSURE IN CASES OF PATENT DUCTUS ARTERIOSUS WITH SPECIAL REFERENCE TO EFFECTS OF SURGICAL CLOSURE' By BOWEN E. TAYLOR,2 ALBERT A. POLLACK,9 HOWARD B. BURCHELL,
More informationCardiovascular Structure & Function
Cardiovascular Structure & Function Cardiovascular system: The heart Arteries Veins Capillaries Lymphatic vessels Weighting of the heart ceremony: Ancient Egyptians William Harvey and Blood Flow April
More informationCirculating Blood Volume in Burn Resuscitation
Hiroshima J. Med. Sci. Vol. 51, No. 1, 7-13, March, 2002 HIJM51-2 7 Circulating Blood Volume in Burn Resuscitation Takeshi INOUE, Kiyoshi OKABAYASHI, Minako OHTANI, Takao YAMANOUE, Seishi WADA and Koji
More informationOPTICAL PERFUSION AND OXYGENATION CHARACTERIZATION IN A LIVER PHANTOM. A Thesis TRAVIS J. KING
OPTICAL PERFUSION AND OXYGENATION CHARACTERIZATION IN A LIVER PHANTOM A Thesis by TRAVIS J. KING Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements
More informationAdministration Hospital, Minneapolis, Minn.) men with disease of the aortic valve or hypertensive heart
STUDIES OF THE PULMONARY CIRCULATION. II. THE CIRCU- LATION TIME FROM THE PULMONARY ARTERY TO THE FEMORAL ARTERY AND THE QUANTITY OF BLOOD IN THE LUNGS IN PATIENTS WITH MITRAL STENO- SIS AND IN PATIENTS
More informationJAMES R. KNIGHT
JAMES R. KNIGHT knightjr@ah.org James is currently the supervisor of clinical engineering at Sonora Regional Medical Center. He is the chairman of the CMIA Training & Education Committee. He also develops
More information