Waterproof quality IP X4
|
|
- June Dickerson
- 6 years ago
- Views:
Transcription
1 Actual size
2 Thanks to its high level of miniaturisation, the R.Test Evolution 3 is compact and lightweight (45 g. batteries included), for total discretion. Its exceptional design ensures high patient compliance, even in cases of long term monitoring (up to 8 days). Suspended around the neck like a medallion, it is retained by an auto-adjustable cable, a particularly ergonomic configuration which drastically limits movement artefacts. The R.Test new housing makes it fully splashproof. In addition, its (medical grade) Polyurethane coating constitutes an efficient protection in cases of exposure to humid environments. An assurance of reliability! Equipped with the exclusive Novacor external artefact rejection technology using piezo-electric sensors, the R.Test Evolution 3 benefits from an excellent Signal Quality. Waterproof quality IP X4 Thanks to an optimised power consumption, the R.Test Evolution 3 ensures 8 days of monitoring with 2 tiny batteries. The advanced micro-electronics are capable of real time QRS acquisition and processing. The R.Test Evolution 3 stores only significant events, thus avoiding the generation of huge data files usually associated with long term ECG monitoring.
3 The R.Test Evolution 3 is now equipped with a new acquisition system favouring the CM5 lead, for excellent results in arrhythmia detection and ST shifts measurement. The PC user interface (RTSoft) is a model of User Friendliness. Patient ID is directly sent to and stored in the recorder before it starts, enhancing Safety in data management. The number and type of events to be recorded as well as the pre and post event time are entirely programmable, allowing either a specific screening for the confirmation of a suspected pathology or a wider search field in the absence of strong clinical evidence. Fast transfer of the recorded data and the display of all the events, plus the heart rate curve and event histograms allow an immediate global overview. Each strip can also be zoomed separately for a detailed analysis. Events selection and report printout can then be done in a couple of mouse clicks. Because we value your time efficiency is at the heart of our innovation!
4 ARRHYTHMIA AND ISCHEMIC EVENTS Paroxysmal Supra Ventricular Tachycardia Ventricular Tachycardia Pause ST shift The automatic recording of supraventricular events as well as relative pauses, associated to the heart rate curve gives the R.Test Evolution 3 an excellent diagnostic yield for Paroxysmal AF (3, 4). Recording of heart rate trend (mean, min and max) and compilation of histograms for all events from the entire monitoring period. Manual recordings for the diagnosis of symptomatic events. Specifically indicated for paediatric cardiology: in addition to its unique design, its algorithms are optimised for paediatric ECG signal processing. Integrated pacemaker spike detection: a long term monitoring tool for the differential diagnosis of arrhythmias in paced patients. * (1) Roche F et al. Accuracy of an automatic and patient-triggered long-term solid memory ambulatory cardiac event recorder. The Am J Cardiol, 1997;80: (2) Balmelli N et al. Efficacy of an automatic and patient-triggered long-term solid memory ambulatory cardiac event recorder in the evaluation of 101 patients with palpitations or syncope. Clin. Cardiol. 2003;26: (3) Roche F et al. Frequent and prolonged asymptomatic episodes of paroxysmal atrial fibrillation revealed by automatic long-term event recorders in patients with a negative 24 hour Holter. Pacing Clin Electrophysiol 2002 Nov;25: (4) Roche F et al. Automatic Cardiac Event recorders reveal Paroxysmal Atrial Fibrillation after Unexplained Strokes or Transient Ischemic Attacks. A.N.E 2003;8:
5 For more than 20 years, Novacor has focused its energy on innovation in Ambulatory Cardiac Monitoring. The R.Test Evolution 3 is a good example of our dedication and know-how. Its clinical power and its ease of use position it as an unrivalled low-cost screening tool in cardiology particularly adjusted to the needs of Health Care Networks. In today s world, economy and efficiency are increasingly important. Innovative tools specially developed for Healthcare Networks and Clinical Trial Organisations allow the R.Test to be set-up and fitted to patients away from the usual Healthcare departments. NovaDrive software facilitates the programming and reading of the R.Test. It can be easily installed on a PC, at any convenient location (GP surgery, private clinic, etc). R.Test recordings can then be transmitted to a centre for expert analysis either by direct connection to a modem or by . Recorded strips as well as real-time ECG can also be transmitted by transtelephonic modulation.
6 A complete system A complete range of accessories has been designed for the R.Test Evolution 3 to ensure optimal performance. TECHNICAL SPECIFICATIONS R.TEST EVOLUTION 3 Length 60 mm Width 48 mm Height 28 mm Weight with batteries 45 g Operating temperature 0 C C Storage temperature -20 C C DECOTEST Length 150 mm Width 133 mm Height 46 mm Weight with batteries 320 g Operating temperature 0 C C Storage temperature -20 C C ACCESSORIES Special Zinc-Air batteries Solid gel electrodes for long term recording Adhesive patches for electrodes CM5 cable Neck cable Metal electrodes R.Test-PC cable R.Test-Modem cable R.Test Evolution 3 is registered trademark of NOVACOR - France Technical specifications subject to changes without notification Revision 1-12/2003 Distributed by: 4, passage Saint Antoine Rueil Malmaison - France Tél. +33 (0) Fax +33 (0) NOVACOR UK Ltd Southern Cross Industrial Estate London Road Swanley Kent BR8 8EE Tel : [44] Fax : [44]
Pathfinder Holter Analyzer CARDIAC DIAGNOSTIC SOLUTIONS
Pathfinder Holter Analyzer CARDIAC DIAGNOSTIC SOLUTIONS Pathfinder Digital - An Evolution... Del Mar Reynolds rich history of innovation began nearly a half century ago with the development of Holter monitoring
More informationHSCRIBE 5 HOLTER ANALYSIS SYSTEM
HSCRIBE 5 HOLTER ANALYSIS SYSTEM freedom Your patients will be free to go about their miniature devices will let them forget they The H3+ digital recorder gives new meaning to the word compact, while providing
More informationMARS Ambulatory ECG Analysis The power to assess and predict
GE Healthcare MARS Ambulatory ECG Analysis The power to assess and predict Connecting hearts and minds Prevention starts with knowledge Around the world, heart disease is one of our fastest-growing health
More informationNovember 2016 POWERFULLY SIMPLE CARDIAC MONITORING. SEEQ External Cardiac Monitor (ECM) System. From the leaders who brought you Reveal LINQ ICM
November 2016 POWERFULLY SIMPLE CARDIAC MONITORING SEEQ External Cardiac Monitor (ECM) System From the leaders who brought you Reveal LINQ ICM TRADITIONAL HOLTER MONITORING TYPICALLY 1-2 DAYS NOT LONG
More information2017/8/23 1. SE-2003&SE-2012 Holter Analysis System
1 SE-2003&SE-2012 Holter Analysis System Process of Holter Analysis Wear a Holter for at least 24 hrs Upload the data & analyze Template categorizing ST analyzing Event selection Other advanced analyzing
More informationAmbulatory Cardiac Monitors and Outpatient Telemetry Corporate Medical Policy
Ambulatory Cardiac Monitors and Outpatient Telemetry Corporate Medical Policy File Name: Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry File Code: UM.SPSVC.13 Origination: 10/2015 Last
More informationPortable, cordless, single-channel ECG Monitor (HCG-801-E) Screening & Self-Monitoring of cardiac events
Screening & Self-Monitoring of cardiac events Portable, cordless, single-channel ECG Monitor (HCG-801-E) Compact - Cordless - Simple operation - Fast - Discrete www.omron-healthcare.com Taking a closer
More informationThe HeartCheck TM PEN Handheld ECG Is your heartbeat slow, fast, or irregular? Are you at risk? Put your heart health in your own hands
The HeartCheck TM PEN Handheld ECG Is your heartbeat slow, fast, or irregular? our hands Are you at risk? Put your heart health in your own hands The first FDA-Cleared device that can be unlocked to allow
More informationA Streamlined Approach to Atrial Fibrillation Screening
A Streamlined Approach to Atrial Fibrillation Screening Partnership between the Cardiac Rhythm Management Team & Department of Stroke Medicine 1 Dowds J, 1 Britton J, 1 McNair W, 1 Turkington L, 1 Curry
More informationCare for Patients Wherever They Are, Wherever You Are.
Care for Patients Wherever They Are, Wherever You Are. Patients want the latest healthcare technology with the least impact on their daily lives. The AliveCor System helps you to partner with your patients
More informationWelch Allyn HScribe Holter Analysis System
Welch Allyn HScribe Holter Analysis System CARDIOLOGY Freedom Empower your patients to go about their daily lives. The H3+ Digital Recorder gives new meaning to the word compact, while providing some of
More informationArrhythmia Care in the DGH What Still Needs to be Done? Dr. Sundeep Puri Consultant Cardiologist
Arrhythmia Care in the DGH What Still Needs to be Done? Dr. Sundeep Puri Consultant Cardiologist LOTS!!! This presentation confines itself to the situation in the North West. The views expressed are my
More informationPOWERFULLY SIMPLE CARDIAC MONITORING
POWERFULLY SIMPLE CARDIAC MONITORING SEEQ Mobile Cardiac Telemetry (MCT) System From the leaders who brought you Reveal LINQ ICM MEDTRONIC CARDIAC DIAGNOSTIC & MONITORING SYSTEMS TRANSFORM Transform your
More informationMEDICAL POLICY Cardiac Event Monitors/ Cardiac Event Detection
POLICY: PG0039 ORIGINAL EFFECTIVE: 10/01/11 LAST REVIEW: 12/12/17 MEDICAL POLICY Cardiac Event Monitors/ Cardiac Event Detection GUIDELINES This policy does not certify benefits or authorization of benefits,
More informationGE Healthcare. The GE EK-Pro Arrhythmia Detection Algorithm for Patient Monitoring
GE Healthcare The GE EK-Pro Arrhythmia Detection Algorithm for Patient Monitoring Table of Contents Arrhythmia monitoring today 3 The importance of simultaneous, multi-lead arrhythmia monitoring 3 GE EK-Pro
More informationZio System Publications. Peer-reviewed publications demonstrating the clinical validity and utility of the Zio system
Zio System Publications Peer-reviewed publications demonstrating the clinical validity and utility of the Zio system Contents Electrocardiographic Responses to Deer Hunting in Men and Women. Wilderness
More informationSpeed - Accuracy - Exploration. Pathfinder SL
Speed - Accuracy - Exploration Pathfinder SL 98000 Speed. Accuracy. Exploration. Pathfinder SL represents the evolution of over 40 years of technology, design, algorithm development and experience in the
More informationClinical Policy: Holter Monitors Reference Number: CP.MP.113
Clinical Policy: Reference Number: CP.MP.113 Effective Date: 05/18 Last Review Date: 04/18 Coding Implications Revision Log Description Ambulatory electrocardiogram (ECG) monitoring provides a view of
More informationName of Policy: Mobile Cardiac Outpatient Telemetry and Hybrid Devices
Name of Policy: Mobile Cardiac Outpatient Telemetry and Hybrid Devices Policy #: 460 Latest Review Date: March 2014 Category: Medical Policy Grade: Effective January 2, 2013, this remains an active policy
More informationDiagnostic capabilities of the implantable therapeutic systems
Cardiac pacing 2012 and beyound Monday August 27, 2012 Diagnostic capabilities of the implantable therapeutic systems Pekka Raatikainen Heart Center Co. Tampere University Hospital and University of Tampere
More informationSyllabus and Program of the Diploma in Cardiac Pacing
Syllabus and Program of the Diploma in Cardiac Pacing 1. The conductive system of the heart(1 hour): Study the anatomical and functional properties of the different componenets of the conductive system
More informationCLINICAL MEDICAL POLICY
Policy Name: Policy Number: Responsible Department(s): CLINICAL MEDICAL POLICY Single-use Ambulatory Electrocardiographic Monitors (e.g., Zio Patch) MP-076-MD-DE Medical Management Provider Notice Date:
More informationAmbulatory ECG Monitoring. Gill Bouncir Blackpool Victoria Hospital
Ambulatory ECG Monitoring Gill Bouncir Blackpool Victoria Hospital History Developed in late 1950 s as a result of research of Dr Norman Holter TYPES Holter - continuous recording. Event recorder- patient
More informationCASE STUDY: THE CLINICAL BENEFIT OF MOBILE CARDIAC OUTPATIENT TELEMETRY. June 22, 2009
CASE STUDY: THE CLINICAL BENEFIT OF MOBILE CARDIAC OUTPATIENT TELEMETRY June 22, 2009 Sanjeev Wasson, MD, FACC, Medical Director, Department of Electrophysiology Skagit Valley Medical Center and Skagit
More information- Non-invasive - Mobile; collect data continuously at anywhere and any time - Used outside clinical setting
Background Advances in medical technologies are increasing remote patient monitoring programs. These technologies enable healthcare professionals to monitor the health status of patients outside clinical
More informationAntony French Consultant Cardiologist & Electrophysiologist
Antony French Consultant Cardiologist & Electrophysiologist Palpitations Unpleasant awareness of rapid or forceful heart beat Not all tachycardias cause palpitations, and not all palpitations are due to
More informationMEDICAL POLICY SUBJECT: AMBULATORY EVENT MONITORS
MEDICAL POLICY SUBJECT: AMBULATORY EVENT MONITORS PAGE: 1 OF: 8 If a product excludes coverage for a service, it is not covered, and medical policy criteria do not apply. If a commercial product, including
More informationThe technology described in this briefing is the Zio Service. It is a remote cardiac monitoring system used for detecting cardiac arrhythmias.
pat hways Zio Service for detecting cardiac arrhythmias Medtech innovation briefing Published: 28 March 20 nice.org.uk/guidance/mib101 Summary The technology described in this briefing is the Zio Service.
More informationA SIMPLE SOLUTION FOR CARDIAC MONITORING
A SIMPLE SOLUTION FOR CARDIAC MONITORING SEEQ Mobile Cardiac Telemetry System Actual size. NOW THERE S AN EXTERNAL HEART MONITOR THAT S AS SIMPLE TO WEAR AS A BANDAGE It s called the SEEQ Mobile Cardiac
More informationCardiac Event Monitors
Last Review Date: July 14, 2017 Number: MG.MM.DM.18aCv2 Medical Guideline Disclaimer Property of EmblemHealth. All rights reserved. The treating physician or primary care provider must submit to EmblemHealth
More informationPatient Resources: Arrhythmias and Congenital Heart Disease
Patient Resources: Arrhythmias and Congenital Heart Disease Overview Arrhythmias (abnormal heart rhythms) can develop in patients with congenital heart disease (CHD) due to thickening/weakening of their
More information2009 CPT Codes for Cardiac Device Monitoring
2009 CPT Codes for Cardiac Device Monitoring December 2008 Notices Current Procedural Terminology (CPT ) is copyright 2008 American Medical Association. All Rights reserved. No fee schedules, basic units,
More informationSCHILLER s medilog Holter system
D I N A N D M A N U F A C T U R E D E D I G N S E E P E U R O SCHILLER s medilog Holter system ECG analysis that meets highest demands medilog DARWIN 2... the unique diagstic tool! With medilog DARWIN
More informationBHRS Prep course Pub style Quiz NOT A
BHRS Prep course Pub style Quiz NOT A Round 1 Quiz questions Common ECG s in CRM Colin Cunnington Over the past 3 months, a 24-yearold man who works as a truck driver has had frequent episodes of pre-syncope
More informationPHYSICIAN S INSERVICE MANUAL Model CN1006 (C5)
PHYSICIAN S INSERVICE MANUAL Model CN1006 (C5) CONTACT INFORMATION CardioNet Monitoring Center Tel. 866-727-3397 For all clinical issues To extend or discontinue monitoring service For fetch requests for
More informationmicroprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE
Technical data Ergometer for cardiac rehabilitation Brake system microprocessor controlled eddy current brake Load / accuracy 6-999 Watt, speed independent / according to DIN VDE 0750-238 Speed range 30-130
More informationAF monitoring and stroke: XPECT & REVEAL LINQ. Helmut Pürerfellner, Linz, Austria
AF monitoring and stroke: XPECT & REVEAL LINQ Helmut Pürerfellner, Linz, Austria 2 Medtronic Confidential 3 Circ Arrhythm Electrophysiol 2010;3:141-47 Reveal XT versus LINQ 5 Parameter Reveal XT Reveal
More informationEmergency Medical Training Services Emergency Medical Technician Paramedic Program Outlines Outline Topic: WPW Revised: 11/2013
Emergency Medical Training Services Emergency Medical Technician Paramedic Program Outlines Outline Topic: WPW Revised: 11/2013 Wolff-Parkinson-White syndrome (WPW) is a syndrome of pre-excitation of the
More informationPanorama. Arrhythmia Analysis Frequently Asked Questions
Panorama Arrhythmia Analysis Frequently Asked Questions What ECG vectors are used for Beat Detection? 3-wire lead set 5-wire lead set and 12 lead What ECG vectors are used for Beat Typing? 3-wire lead
More informationTOP 3: EMBRACE. Lucy Vieira MD FRCP Neurologist MUHC. N Engl J Med Volume 370(26): June 26, David J.
TOP 3: EMBRACE N Engl J Med Volume 370(26):2467-2477 June 26, 2014 David J. Gladstone et al Lucy Vieira MD FRCP Neurologist MUHC Receiving research funds AstraZeneca 2014-2016 Original Article Atrial Fibrillation
More informationCONFIRM Rx INSERTABLE CARDIAC MONITOR CONTINUOUS HEART MONITORING LIVE LIFE WITHOUT SKIPPING A BEAT
CONFIRM Rx INSERTABLE CARDIAC MONITOR CONTINUOUS HEART MONITORING LIVE LIFE WITHOUT SKIPPING A BEAT FIND YOUR RHYTHM DON T IGNORE THE SYMPTOMS OF AN IRREGULAR HEARTBEAT 7.1 MILLION Up to 7.1 million people
More informationMEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring
MEDTRONIC CARELINK NETWORK FOR PACEMAKERS Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring Transtelephonic Monitoring Transmission What can you determine
More informationΧρήση έξυπνων τεχνολογιών στην ανίχνευση κολπικής μαρμαρυγής Use of smart technology in atrial fibrillation detection
Χρήση έξυπνων τεχνολογιών στην ανίχνευση κολπικής μαρμαρυγής Use of smart technology in atrial fibrillation detection Χάρης Κοσσυβάκης Επιμελητής A Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ» Risk of Stroke
More informationRobust Detection of Atrial Fibrillation for a Long Term Telemonitoring System
Robust Detection of Atrial Fibrillation for a Long Term Telemonitoring System B.T. Logan, J. Healey Cambridge Research Laboratory HP Laboratories Cambridge HPL-2005-183 October 14, 2005* telemonitoring,
More informationAmbulatory Cardiac Monitoring Modalities
Ambulatory Cardiac Monitoring Modalities NAVIGATING THE CHOICES MKT0390.03 LEARNING OBJECTIVES Identify the Clinical Applications for Each Modality Define and Distinguish Between the Various Monitoring
More informationpowerful versatile mobile
M9 Premium Compact Ultrasound System powerful versatile mobile M9 Premium Compact Ultrasound System powerful versatile mobile Powerful Platform With the next generation of technologies, the Mindray M9
More informationInteractive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators
22 March 2002 Interactive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators F. HINTRINGER, O. PACHINGER Division of Cardiology, Department for Internal Medicine, University
More informationDiploma in Electrocardiography
The Society for Cardiological Science and Technology Diploma in Electrocardiography The Society makes this award to candidates who can demonstrate the ability to accurately record a resting 12-lead electrocardiogram
More informationDC-40 Ultrasound System. powerful efficient sleek
DC-40 Ultrasound System powerful efficient sleek To deliver on the promise of quality healthcare within reach, Mindray s DC-40, the next generation of shared service ultrasound systems, incorporates innovative
More informationDefibrillators TEC-8300K series. Improving quality of resuscitation
Defibrillators TEC-8300K series Improving quality of resuscitation Transitioning back to life For intensive treatment and advanced life support Pre-hospital Out-of-hospital 12-lead ECG acquisition and
More informationCardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.
Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc. The Miracle of Living February 21, 2018 Matthew Ostrom MD,FACC,FHRS Division of
More informationCARDIAC MONITORING THE EARLY DAYS
CARDIAC MONITORING THE EARLY DAYS CARDIAC MONITORING - TODAY SEEQ Mobile cardiac telemetry system for short-term monitoring up to 30 days Reveal LINQ Insertable cardiac monitoring system for long-term
More informationECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR
ECHOLAB Otoacoustic Emissions System - DPOAE - ABR - AABR Screening and Clinical Modality User Programmable Protocols ECHOLAB Otoacoustic Emissions System - DPOAE - ABR - AABR All of Labat s technology
More informationNHA Certified EKG Technician (CET) Test Plan for the CET Exam
NHA Certified EKG Technician (CET) Test Plan for the CET Exam 100 scored items Exam Time: 2 hours *Based on the results of a job analysis completed in 2017 This document provides both a summary and detailed
More informationRemote Monitoring & the Smart Home of the 21 Century
Cardiostim EHRA Europace 2016, Nice - June 8-11, 2016 Remote Monitoring & the Smart Home of the 21 Century Antonio Raviele, MD, FESC, FHRS President ALFA -Alliance to Fight Atrial fibrillation- Venezia
More informationLong-Term ECG Monitoring Using an ILR. Evgeny Pokushalov, MD, PhD
Long-Term ECG Monitoring Using an ILR Evgeny Pokushalov, MD, PhD Long- Term ECG Monitoring Using an ILR Evgeny Pokushalov, MD, PhD, FESC State Research Ins;tute of Circula;on Pathology, Novosibirsk, Russia
More informationepatch - A Clinical Overview
1 epatch - A Clinical Overview epatch Research Unit * I. WHY WE DESIGNED THE EPATCH Since the first Holter recorders were invented in the 1940s there has been a tremendous development in the capabilities
More informationMedicare Advantage Medical Policy
Medicare Advantage Medical Policy Current Policy Effective Date: 1/1/18 Title: Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry Description/Background Indications for Ambulatory Cardiac
More informationSabri DEMIRCAN Istanbul Bilim University Department of Cardiology
abri DEMIRCN Istanbul Bilim University Department of Cardiology H/CC/HR Guideline for the Management of Patients With trial Fibrillation. J m Coll Cardiol 4;64:46-8. European Heart Journal () 3, 369-49
More informationAmbulatory Event Monitors and Mobile Cardiac Outpatient Telemetry
Ambulatory Event Monitors and Mobile Cardiac Page: 1 of 20 Last Review Status/Date: March 2015 Ambulatory Event Monitors and Mobile Cardiac Description There are a wide variety of devices available for
More informationAmbulatory Event Monitors and Mobile Cardiac Outpatient Telemetry
Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry Policy Number: 2.02.08 Last Review: 9/2018 Origination: 11/2002 Next Review: 9/2019 Policy Blue Cross and Blue Shield of Kansas City (Blue
More informationWHY AM I FAINTING? Finding answers about unexplained fainting
WHY AM I FAINTING? Finding answers about unexplained fainting PERSONAL STORIES For about 15 years, Lloyd s friends and family thought he was clumsy. Each spring, he seemed to have an unusual accident.
More informationCommunity Cardiology Service - Reinventing Care
Cardiology Community Cardiology Service - Reinventing Care Dr Dilsher Singh Clinical Cardiology Lead Connected care Partnership Background Evidence of Need Cardiology accounts for high volumes of OP activity
More informationManual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev
Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing D. J. McMahon 141001 cewood rev 2017-10-04 Key Points Defibrillators: - know the definition & electrical value
More informationProfessional body composition analysis: BODYSTAT I500. Touch Screen THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.
Professional body composition analysis: BODYSTAT I500 Touch Screen THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT www.bodystat.com ADVANCED BODY COMPOSITION THE HEALTH, FITNESS & LEISURE TAKE YOUR BUSINESS
More informationNational Coverage Determination (NCD) for Cardiac Pacemakers (20.8)
Page 1 of 12 Centers for Medicare & Medicaid Services National Coverage Determination (NCD) for Cardiac Pacemakers (20.8) Tracking Information Publication Number 100-3 Manual Section Number 20.8 Manual
More informationEHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs
EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs Dear EHRA Member, Dear Colleague, As you know, the EHRA Accreditation Process is becoming increasingly recognised as an important step for
More informationEEG, ECG Measurement and Data Analysis. Carlo Lucignoli. ATSiP Teesside 2006
EEG, ECG Measurement and Data Analysis Carlo Lucignoli ATSiP Teesside 2006 What are we trying to achieve? The psychologists wish to measure patients anxiety. The measurement is shown to patients so they
More informationthe truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines
the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines advanced TEOAE, DPOAE and AABR technologies with fully automated results and completely standardized, pre-
More informationNeurostyle. Medical Innovation for Better Life
Neurostyle Medical Innovation for Better Life Neurostyle Pte Ltd is a company dedicated to design, develop, manufacture and distribute neurological and neuromuscular medical devices. Strategically located
More informationLa strategia diagnostica: il monitoraggio ecg prolungato. Michele Brignole
La strategia diagnostica: il monitoraggio ecg prolungato Michele Brignole ECG monitoring and syncope In-hospital monitoring Holter Monitoring External loop recorder Remote (at home) telemetry Implantable
More informationAmbulatory Event Monitors and Mobile Cardiac Outpatient Telemetry
Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry Policy Number: Original Effective Date: MM.02.021 02/01/2014 Line(s) of Business: Current Effective Date: HMO; PPO; QUEST Integration 07/27/2018
More informationERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H
ERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H Therapy by design One of the major goals of cardiac rehabilitation is to systematically improve the performance of the cardiovascular system. The
More informationClinical Investigations
Clinical Investigations New Real-Time Loop Recorder Diagnosis of Symptomatic Arrhythmia Via Telemedicine Address for correspondence: Eran Leshem-Rubinow, MD Department of Internal Medicine E Tel Aviv Sourasky
More informationPRP-100-GB. Instruction Manual
PRP-100- Instruction Manual Thank you for choosing HoMedics products. Please read these instructions for use carefully and keep them for further use. WARNINGS Never use this unit near the heart, around
More informationMedical Policy An independent licensee of the Blue Cross Blue Shield Association
Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry Page 1 of 33 Medical Policy An independent licensee of the Blue Cross Blue Shield Association Title: Ambulatory Event Monitors and Mobile
More informationWelch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.
Welch Allyn ABPM 6100S Comprehensive blood pressure monitoring that brings patient comfort home. Features and Benefits of the Welch Allyn ABPM 6100S Pictorial application instructions, artery markers and
More informationTop 5 Things to Know about Pacemakers and ICD s. Jeffrey S. Osborn, M.D., C.C.D.S. March 4, 2017.
Top 5 Things to Know about Pacemakers and ICD s Jeffrey S. Osborn, M.D., C.C.D.S. March 4, 2017. Top 5 Things 1. Remote Monitoring leads to better care and outcomes. 2. MRI s CAN be done on device patients.
More informationClinical and Electrocardiographic Characteristics of Patients with Brugada Syndrome: Report of Five Cases of Documented Ventricular Fibrillation
J Arrhythmia Vol 25 No 1 2009 Original Article Clinical and Electrocardiographic Characteristics of Patients with Brugada Syndrome: Report of Five Cases of Documented Ventricular Fibrillation Seiji Takashio
More informationAtrial Fibrillation. Ivan Anderson, MD RIHVH Cardiology
Atrial Fibrillation Ivan Anderson, MD RIHVH Cardiology Outline Definition and Pathophysiology Rate versus rhythm control Rate control thresholds (how much is enough) Anti-coagulation CHADS2VASc score HASBLED
More informationElectrocardiography for Healthcare Professionals
Electrocardiography for Healthcare Professionals Kathryn A. Booth Thomas O Brien Chapter 5: Rhythm Strip Interpretation and Sinus Rhythms Learning Outcomes 5.1 Explain the process of evaluating ECG tracings
More informationEPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE
EPIC-PLUS System for auditory evoked potentials and neuro-otology PEA - VEMPs ASSR - E-ABR FACIAL NERVE EPIC-PLUS System for auditory evoked potentials and neuro-otology Epic-plus, a unique solution. With
More informationQUESTION: In a patient with different QT intervals, which one will give the highest prognostic accuracy? REPLY:
QUESTION: In a patient with different QT intervals, which one will give the highest prognostic accuracy? REPLY: First, there are two possibilities: I) It is not known, if the patient (subject) presented
More informationthe truly automated all-in-one hearing screener
the truly automated all-in-one hearing screener ONLY THE ECHO-SCREEN HEARING SCREENER COMBINES ADVANCED TEOAE, DPOAE AND AABR TECHNOLOGIES WITH FULLY AUTOMATED RESULTS AND COMPLETELY STANDARDIZED, PRE-
More informationHeart rhythm analysis using ECG recorded with a novel sternum based patch technology
Downloaded from orbit.dtu.dk on: Apr 17, 2018 Heart rhythm analysis using ECG recorded with a novel sternum based patch technology Saadi, Dorthe Bodholt; Fauerskov, Inge; Osmanagic, Armin; Sheta, Hussam
More informationLATITUDE Patient Management System
LATITUDE Patient Management System Boston Scientific Corporation Overview Key Benefits Benefits in HF-Management The future of RPM 2 Boston Scientific Corporation LATITUDE Patient Management Overview Patient
More informationSimple is better. MAC 2000 ECG analysis system
Simple is better Simple is Productive Simple is Connected Simple is Reliable Product overview MAC 2000 ECG analysis system Simple is productive Simple is Productive Simple is Connected Simple is Reliable
More informationSJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.
SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000 1 APPROVED MRI SCAN CONDITIONS 1.5 TESLA FULL BODY 2 SETUP SJM MRI ACTIVATOR HANDHELD DEVICE The SJM MRI Activator handheld device must be enabled
More informationTriAuto mini Compact, Cordless Endodontic Handpiece
TriAuto mini Compact, Cordless Endodontic Handpiece Thinking ahead. Focused on life. Lightweight with Compact Head and Body The refined, compact design of TriAuto mini s head and body is very small and
More informationResting and Stress ECG
Operating Manual Resting and Stress ECG 1 Safety 2 Hardware 3 Software 4 Hygiene Part 3: Operating characteristics: custo diagnostic 5.0 and higher for Windows MSW 0001 DK 1660 Version 002 13/06/2018 2018
More informationCARDIOVIT CS-200. The Gold Standard. Innovations are our passion. The CARDIOVIT CS-200 is the key to complete diagnostic services, including:
CARDIOVIT CS-200 The Gold Standard The CARDIOVIT CS-200 is the key to complete diagnostic services, including: 12-channel Resting ECG Automatic ECG measurements and interpretation (adult and pediatric)
More informationAssessing Arrhythmia Performance ST/AR Algorithm
Assessing Arrhythmia Performance ST/AR Algorithm Application Note This report provides the arrhythmia performance of the ST/AR (ST and Arrhythmia) algorithm. For a description of the algorithm, see the
More informationAmbulatory Event Monitors and Mobile Cardiac Outpatient Telemetry Section 2.0 Medicine Subsection 2.02 Cardiology
2.02.08 Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry Section 2.0 Medicine Subsection 2.02 Cardiology Effective Date December 31, 2014 Original Policy Date April 5, 2007 Next Review
More informationGSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard
GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER New Standard for Clinical Impedance The GSI TympStar Pro is setting the clinical standard for performing a full
More informationReview of devices for early AF detection Nadya Hamedi Primary Care cardiovascular pharmacist Health innovation Network
Review of devices for early AF detection Nadya Hamedi Primary Care cardiovascular pharmacist Health innovation Network n.hamedi@nhs.net HRC 2016 The ICC Birmingham UK 9-12 October 2016 PAN London AF Improvement
More informationCardiac Dysrhythmias and Sports
Sudden unexpected death during athletic participation is the overriding consideration in advising individuals with dysrhythmias about participation in sports. The incidence of sudden death is 1 to 2 per
More informationImplantable Cardiac Monitors for Atrial Fibrillation (AF) Detection: Ready for Routine Use?
Implantable Cardiac Monitors for Atrial Fibrillation (AF) Detection: Ready for Routine Use? Helmut Pürerfellner, MD, Assoc. Prof. Saint Elisabeth s Sisters Hospital Academic Teaching Center Linz/Austria
More informationUsing Apple Watch for Arrhythmia Detection. December 2018
Using Apple Watch for Arrhythmia Detection December 2018 Contents Overview 3 Introduction... 3 PPG-based arrhythmia detection 3 Technical and Feature Description... 3 Preclinical Development... 4 Clinical
More informationMini Pulse Electronic Stimulator
Mini Pulse Electronic Stimulator Model: PM-180 Operating Manual IMPORTANT: Please read all instructions before using this product. Retain this manual for future reference. www.santamedical.com IMPORTANT
More informationOHTAC Recommendation: Internet- Based Device-Assisted Remote Monitoring of Cardiovascular Implantable Electronic Devices
OHTAC Recommendation: Internet- Based Device-Assisted Remote Monitoring of Cardiovascular Implantable Electronic Devices Ontario Health Technology Advisory Committee January 2012 Issue Background The Ontario
More information