Embolization of atherothrombotic debris occurs commonly

Size: px
Start display at page:

Download "Embolization of atherothrombotic debris occurs commonly"

Transcription

1 Randomized Comparison of Distal Protection With a Filter-Based Catheter and a Balloon Occlusion and Aspiration System During Percutaneous Intervention of Diseased Saphenous Vein Aorto-Coronary Bypass Grafts Gregg W. Stone, MD; Campbell Rogers, MD; James Hermiller, MD; Robert Feldman, MD; Patrick Hall, MD; Robert Haber, MD; A. Masud, MD; Patrick Cambier, MD; Ron P. Caputo, MD; Mark Turco, MD; Richard Kovach, MD; Bruce Brodie, MD; Howard C. Herrmann, MD; Richard E. Kuntz, MD; Jeffrey J. Popma, MD; Steve Ramee, MD; David A. Cox, MD; for the FilterWire EX Randomized Evaluation (FIRE) Investigators Background The high rate of periprocedural complications resulting from atherothrombotic embolization after percutaneous intervention in diseased saphenous vein grafts is reduced by distal microcirculatory protection using a balloon occlusion and aspiration system. Whether filter-based catheters, which offer the inherent advantages of maintained perfusion and ease of use, are as effective for this purpose has not been established. Methods and Results A total of 651 patients undergoing percutaneous intervention of 682 saphenous vein graft lesions were prospectively randomized to distal protection with the filter-based FilterWire EX versus the GuardWire balloon occlusion and aspiration system. Device success was 95.5% and 97.2% with the FilterWire EX and GuardWire, respectively (P 0.25). Postprocedural measures of epicardial flow and angiographic complications were similar between the 2 groups, although bailout IIb/IIIa inhibitors were required slightly less frequently in the FilterWire EX group (0% versus 1.5%, P 0.03). The primary end point, the composite incidence of death, myocardial infarction, or target vessel revascularization at 30 days, occurred in 9.9% of FilterWire EX patients and 11.6% of GuardWire patients (difference [95% CI] 1.7% [ 6.4%, 3.1%]; P for superiority 0.53, P for noninferiority ). Conclusions Distal protection with the FilterWire EX may be safely used as an adjunct to percutaneous intervention of diseased saphenous vein grafts and, compared with distal protection with the GuardWire balloon occlusion and aspiration system, results in similar rates of major adverse cardiac events at 30 days. (Circulation. 2003;108: ) Key Words: grafting stent complications Embolization of atherothrombotic debris occurs commonly during percutaneous coronary intervention (PCI) of diseased saphenous vein bypass grafts (SVGs), frequently resulting in periprocedural myocardial infarction (MI). 1 4 In a multicenter, randomized trial, protection of the distal microcirculation by a balloon occlusion and aspiration system (Medtronic GuardWire) significantly reduced the occurrence of angiographic and clinical complications during stent implantation in SVGs 5 and is therefore presently accepted as the standard therapy for this application. Balloon occlusion devices, however, obligate a several-minute duration of ischemia that may result in severe angina and left ventricular dysfunction with hypotension and necessitate a hurried procedure. In contrast, distal protection with catheterbased filters maintains antegrade perfusion 6,7 and may thus be preferable in selected patients. However, distal filters are larger profile than the GuardWire and possess their own set of technical and operator-related issues that may adversely impact outcomes. 7 We therefore performed a pivotal, multicenter randomized trial to evaluate the safety and efficacy of distal microcirculatory protection with a novel filter-based catheter compared with the GuardWire balloon occlusion and aspiration device during PCI of diseased SVGs. Received April 9, 2003; revision received April 29, 2003; accepted May 5, From the Cardiovascular Research Foundation and Lenox Hill Heart and Vascular Institute, New York, NY. Drs Stone, Hermiller, and Herrmann serve as consultants to Boston Scientific Corp (BSC); Dr Caputo is a member of the BSC advisory board; Dr Cox is an advisor to BSC; Drs Feldman and Ramee each have a small amount of equity in BSC; Drs Masud, Popma, Herrmann, and Cox receive research funding from BSC; Dr Rogers is on the speaker s bureau for BSC; and Dr Stone serves as a consultant to Medtronic. A complete list of the FilterWire EX Randomized Evaluation investigators and study organization appears in the online-only Appendix available at Correspondence to Gregg W. Stone, MD, Cardiovascular Research Foundation, 55 E 59th St, 6th Floor, New York, NY gstone@crf.org 2003 American Heart Association, Inc. Circulation is available at DOI: /01.CIR A 548

2 Stone et al Distal Protection Device Comparison 549 TABLE 1. Baseline Clinical Characteristics of the Study Population FilterWire EX GuardWire P No. patients, No. lesions 332, , 334 Age, y Male, % Hypertension, % Hyperlipidemia, % Smoking within 1 year, % Diabetes mellitus, % Prior MI, % Peripheral vascular disease, % Cerebrovascular disease, % Canadian Heart Association angina class, % I II III IV Left ventricular ejection fraction, % SVG age, y Methods Patient Selection Patients 21 years old undergoing PCI with planned stenting of 1 or more de novo lesions in diseased SVGs were eligible for enrollment. Exclusion criteria included acute or recent MI or current elevation of creatine phosphokinase (CPK)-MB isoenzyme, uncontrollable allergy or contraindication to contrast or any of the study medications, cerebrovascular event within 2 months, serum creatinine 2.5 mg/dl, prior target vessel PCI within 30 days or planned multivessel intervention in which not all lesions met study enrollment criteria, SVG age 6 months, true aorto-ostial lesion 10 mm in length, reference vessel diameter 3.5 mm or 5.5 mm, TIMI 0 flow, lesion within 2.5 cm of the distal anastomosis or 2 cm of relatively straight vessel distal to the lesion not present, unprotected Y-limb branch vessel proximal to the study device, planned use of laser or atherothrombectomy devices, or left ventricular ejection fraction 25%. The Investigational Review Board at each site approved the protocol, and all patients provided informed written consent. Randomization and Interventional Protocol Aspirin 325 mg was administered before the procedure. A 300-mg clopidogrel or 500-mg ticlopidine load was recommended before the procedure but was administered in all cases within 4 hours after the procedure. Glycoprotein IIb/IIIa inhibitor use was left to the discretion of the investigator. Intravenous heparin was administered to maintain the procedural activated clotting time to 300 seconds ( 200 seconds if a IIb/IIIa inhibitor was used). Randomization was stratified by intended IIb/IIIa inhibitor administration. Patients were randomized 1:1 to either distal protection with the FilterWire EX system (Boston Scientific) or the GuardWire (Medtronic). As previously described, the FilterWire EX consists of a distal polyurethane filter with 110- m diameter pores mounted on a in steerable guide wire via a spinner tube, which permits unrestricted wire rotation and steering. 7 The filter is attached to an elliptical, eccentric self-expanding radiopaque nitinol loop, deployed after crossing the lesion by retracting a restraining 3.9F delivery sheath. The elliptical loop maximizes the cross-sectional area exposed to the bloodstream and affords apposition of vessels ranging from 3.5 to 5.5 mm in diameter. PCI is then performed over the guide wire, with maintained antegrade perfusion carrying the liberated atherosclerotic and thrombotic debris distally into the filter. The filter is then closed with a retrieval sheath and the retained debris removed. In contrast, the GuardWire consists of a in guide wire incorporating a central inflation lumen to which an elastomeric balloon is attached distally. 5,8 The crossing profile is in ( 2.8F). Once distal to the lesion, injection of diluted contrast results in balloon inflation (3.0- to 6.0-mm-diameter range) with subsequent cessation of antegrade blood flow. Actuating the MicroSeal adapter closes a proximal valve in the GuardWire, allowing the inflation syringe to be disconnected, after which intervention is performed over the wire. Liberated debris is suspended within a stagnant column of blood and is aspirated through the 5F monorail Export Catheter. The GuardWire balloon is then deflated and flow restored. Once distal protection was established, stenting was performed using approved devices and standard techniques. The decision of whether to perform balloon angioplasty before or after stent implantation was left to the discretion of the operator. CPK-MB levels were measured at least 3 times after the procedure within the first 24 hours, and a 12-lead ECG was obtained immediately and before TABLE 2. Baseline Angiographic Characteristics (Core Laboratory) FilterWire EX GuardWire P No. patients, No. lesions 332, , 334 SVG distribution, % LAD LCX RCA SVG lesion location, % Proximal With ostial involvement Mid Distal Lesion length, mm Reference vessel diameter, mm Minimal luminal diameter, mm Diameter stenosis, % TIMI flow, % 0/ TIMI frame count Eccentric, % Tortuous, % Bend 45 degrees, % Calcification, % Irregular, % Ulcerated, % Aneurysmal, % Thrombus, % SVG degeneration score,* % *Axial length of lumen irregularities or ectasia expressed as a percent of the entire SVG length. LAD indicates left coronary descending; LCX, left coronary circumflex; and RCA, right coronary ascending.

3 550 Circulation August 5, 2003 TABLE 3. Procedural Outcomes and Angiographic Results FilterWire EX GuardWire P No. patients, No. lesions 332, , 334 Procedure duration,* min Device success, % Failure to deliver device, % Failure to deploy filter, % 0.6 Failure to inflate balloon, % 0.9 Failure to maintain occlusion, or rupture, % 1.2 Clinical success, % IIb/IIIa inhibitors used before intervention, % IIb/IIIa inhibitors used during procedure, % Stents implanted, % No. of stents implanted per lesion Total length of stents, mm Maximal device size, mm Maximal inflation pressure, atm Reference vessel diameter after procedure, mm In-stent minimal luminal diameter after procedure, mm In-stent diameter stenosis after procedure, % In-lesion minimal luminal diameter after procedure, mm In-lesion diameter stenosis after procedure, % TIMI flow post, % 0/ Thrombus, % Dissection, % Perforation, % Distal embolus, % *Time from arterial puncture to guide catheter removal. discharge. Aspirin was continued indefinitely, and a thienopyridine was continued for 4 weeks if stents were implanted. Definitions, End Points, and Statistical Analysis The primary end point of the study was the 30-day composite occurrence of major adverse cardiac events (MACE), including death, MI, or target vessel revascularization. An MI was defined as any postprocedural CK-MB elevation to 3 times normal. The development of new, pathological Q waves in 2 contiguous leads (assessed by a blinded ECG Core Laboratory) was required to diagnose a Q-wave MI. All primary end point events were adjudicated by an independent committee blinded to treatment allocation. Device success for the FilterWire EX was defined as the ability to deliver, deploy, and retract a device at and from the desired target location. Device success for the GuardWire was defined as the ability to deliver a device to the desired target, obtain distal occlusion, and perform aspiration without loss of occlusion attributable to leak or rupture. Clinical success was defined as device success with a final lesion diameter stenosis 50% without inhospital MACE. Angiographic films were analyzed in a central core laboratory using previously validated techniques. 9 The sample size was chosen to demonstrate that the FilterWire EX was noninferior (ie, equivalent or superior) to the GuardWire. 10 Assuming that the 30-day MACE rates for both the control and study device were 10%, randomizing 618 patients would provide 80% power to demonstrate noninferiority with 1-sided error of 5% and of 6%. Categorical variables were compared by the likelihood ratio 2 test or Fisher s exact test. Continuous variables are presented as mean SD and were compared by 1-way ANOVA or unpaired t test. The influence of baseline demographic features, angiographic variables, and treatment assignment on 30-day outcomes was evaluated using logistic regression. All analyses were by intention to treat, and all P values are 2-sided. Statistical significance was determined at the P 0.05 level. Results Patient Population Between October 2001 and September 2002, 651 patients at 66 sites in the United States and Canada undergoing stent implantation in 682 SVG lesions were randomized. As seen in Table 1, the population was elderly and characterized by a high incidence of hypertension, hyperlipidemia, diabetes, and prior MI. Baseline angiographic characteristics were well matched between the 2 groups, except that grafts randomized to the GuardWire had a slightly worse degeneration score (Table 2). Thrombus was present in approximately one quarter of lesions, and TIMI flow was reduced in 20% of vessels.

4 Stone et al Distal Protection Device Comparison 551 Figure 1. Primary end point MACE rates at 30 days in patients randomized to the FilterWire EX (black bars) or the GuardWire (white bars). indicates absolute difference; HR, hazard ratio. Procedural Results Device and clinical success rates were similar with both devices (Table 3). IIb/IIIa inhibitors were used in approximately half of patients in both groups before the procedure, although the bailout use of these agents was slightly more frequent in patients assigned to the GuardWire. Stent sizing was slightly greater in the GuardWire arm, although inflation pressures were higher in the FilterWire EX arm. Quantitative and qualitative angiographic results and epicardial coronary flow rates were similar in both arms, except for a slightly lower in-lesion diameter stenosis with the FilterWire EX device (Table 5). In-Hospital and 30-Day Clinical Outcomes In-hospital MACE occurred in 9.6% of FilterWire EX patients compared with 10.7% of GuardWire patients (difference [95% confidence interval] 1.0% [ 5.7 to 3.6], P 0.67). As shown in Figure 1, the primary composite 30-day MACE end point occurred in 9.9% of FilterWire EX patients and 11.6% of GuardWire patients (P 0.53). The 1-sided test of noninferiority was met at the P level. With 95% confidence, absolute 30-day MACE rates with the FilterWire EX compared with the GuardWire could range from 6.4% better to 3.1% worse or by relative measures from 45% better to 33% worse. Most MACE events consisted of non Q-wave MIs (Table 4). As seen in Figure 2, the extent of periprocedural myonecrosis was nearly identical with both the FilterWire EX and GuardWire devices. Figure 2. Cumulative frequency distribution curves of peak postprocedural CPK-MB for patients randomized to distal protection with the FilterWire EX ( ) versus the GuardWire ( ). Each curve shows the percentage of patients whose CPK-MB elevation (expressed as a multiple of institutional upper limit of normal) exceeds the value on the X-axis. Compared with the GuardWire, 30-day MACE rates were lower with the FilterWire EX in smaller vessels and eccentric lesions; MACE rates were statistically similar with the 2 protection devices stratified by other angiographic variables (Table 5). By multivariate analysis, however, only the number of stents and total stent length were independently correlated with 30-day MACE in the entire population (Table 6). Discussion In the present study, the first to examine the comparative efficacy of distal microcirculatory protection with 2 competitive technologies, the 30-day outcomes of PCI in diseased SVGs using the FilterWire EX system were noninferior (ie, statistically equivalent or better) to those with the predicate GuardWire system. Postprocedural measures of epicardial flow, angiographic complications, and the extent of myonecrosis were also similar between the 2 groups, although bailout use of glycoprotein IIb/IIIa inhibitors was required slightly more frequently with the GuardWire. The baseline features of the patients in the present trial were similar to those in the Saphenous vein graft Angioplasty Free of Emboli Randomized (SAFER) trial, 5 the pivotal study that established the GuardWire as the standard of care for TABLE 4. MI Classification by Peak Postprocedural CPK-MB Levels and New Q-Wave Formation After the Index Procedure* FilterWire GuardWire P No. patients Type 3 MI (Q-wave or CPK-MB 8 ULN), % Q-wave MI, % CPK-MB elevation 8 ULN, % Type 2 CPK-MB elevation 3 to 8 ULN, % Type 2 CPK-MB elevation 1 to 3 ULN with ECG changes, % Type 1 CPK-MB elevation 1 to 3 ULN, % Any CPK-MB elevation ULN to 30 days, % *Only MIs occurring immediately after the index procedure were classified as types 1 through 3 non Q-wave MI. ULN indicates upper limits of normal.

5 552 Circulation August 5, 2003 TABLE 5. Thirty-Day MACE Stratified by Baseline Clinical and Angiographic Characteristics Variable FilterWire EX, % GuardWire, % Risk Ratio (95% CI) P Diabetes (0.23 to 1.54) 0.29 No diabetes (0.57 to 1.87) 0.91 Stable angina (0.51 to 2.25) 0.85 Unstable angina (0.35 to 1.45) 0.35 SVG graft age 10 years (0.25 to 1.14) 0.10 SVG graft age 10 years (0.62 to 2.47) 0.55 Reference vessel diameter median (3.3 mm) (0.13 to 0.76) 0.01 Reference vessel diameter 3.3 mm (0.76 to 3.02) 0.24 Minimal luminal diameter 1 mm (0.27 to 1.62) 0.36 Minimal luminal diameter 1 mm (0.47 to 1.69) 0.72 Diameter stenosis 70% (0.50 to 1.90) 0.94 Diameter stenosis 70% (0.25 to 1.37) 0.22 Lesion length median (13 mm) (0.28 to 1.45) 0.28 Lesion length 13 mm (0.55 to 2.23) stent implanted (0.65 to 4.24) stents implanted (0.33 to 1.26) 0.20 Stent length implanted median (20 mm) (0.31 to 5.63) 0.71 Stent length implanted 20 mm (0.50 to 1.55) 0.65 TIMI 0 to 2 flow (0.11 to 1.25) 0.11 TIMI 3 flow (0.52 to 1.70) 0.85 Lesion eccentric (0.24 to 0.95) 0.04 Lesion concentric (0.75 to 4.07) 0.20 Thrombus (0.38 to 1.26) 0.22 No thrombus (0.43 to 3.83) 0.66 Ostial or proximal lesion (0.36 to 1.69) 0.52 Mid or distal lesion (0.42 to 1.71) 0.65 SVG degeneration score 25% (0.63 to 4.08) 0.32 SVG degeneration score 25% (0.33 to 1.27) 0.20 IIb/IIIa inhibitor used (0.32 to 1.17) 0.14 No IIb/IIIa inhibitor used (0.62 to 3.09) 0.43 distal protection during SVG intervention. The 11.6% 30-day MACE rate with the GuardWire in the present trial is also similar to the 9.6% rate with the same device in SAFER. Moreover, major device failure with the GuardWire was less in the present trial (2.3%) than reported in the SAFER trial, in which inability to deliver the device or maintain vessel occlusion occurred in 8.6% of patients. It is therefore unlikely that the relatively favorable results with the FilterWire EX system in the present trial are explained by suboptimal results in the control (GuardWire) arm. Thus, within the framework of the inclusion and exclusion criteria that dictated patient selection in this trial, physicians may be 95% confident that use of the FilterWire EX will result in 30-day MACE rates ranging from 45% better than with the GuardWire (absolute 6.4% less MACE) to 33% worse (absolute 3.1% greater MACE). These data are also consistent with the hypothesis that the FilterWire EX is better than control (putative placebo effect), given the 42% treatment effect versus placebo seen in SAFER, using the same definitions as in the present study. Subtle differences in outcomes may not have been revealed by this study. For example, it was not possible to measure transient intraprocedural events, because the GuardWire results in total vessel occlusion whereas the FilterWire EX typically preserves antegrade perfusion throughout most or all of the procedure. It is also difficult to quantify the relative benefits of ease of use with filter-based distal protection devices, because the ischemia that results with balloon occlusion and aspiration mandates extremely rapid work, which may paradoxically result in shorter procedural times or reduced contrast use. Whether the more relaxed pace of filter-based distal protection allows more considered and appropriate decision-making cannot be answered by the present study. In this regard it is interesting that slightly larger stents were chosen in the GuardWire arm, but slightly greater stent inflation pressures were used with the FilterWire EX. Whether these parameters were affected by the choice of distal protection device is speculative. The diameter stenosis achieved was also slightly lower with the FilterWire EX, although the clinical significance of this slight improvement is doubtful. Although exploratory subgroup analyses demonstrated a possible benefit of the FilterWire EX compared with the GuardWire in smaller vessels and eccentric lesions, the

6 Stone et al Distal Protection Device Comparison 553 TABLE 6. Independent Correlates of 30-Day MACE Variable Risk Ratio (95% CI) P Entire population No. of stents ( 2 vs 1) 2.54 (1.27 to 5.07) Total length of stents median (20 mm) 3.44 (1.46 to 8.11) FilterWire EX patients Total length of stents median (20 mm) 4.98 (1.95 to 12.75) Reference vessel diameter median (3.3 mm) 2.55 (1.07 to 6.10) 0.03 GuardWire patients No. of stents ( 2 vs 1) 6.56 (2.70 to 15.93) SVG degeneration score ( 25% vs 25%) 3.80 (1.55 to 9.32) mechanistic explanation for these observations is uncertain, and these findings may be attributable to chance given multiple comparisons. The outcomes with both protection devices were statistically indistinct in other lesion and vessel subtypes, although this study was underpowered to detect variables that might favor one device rather than the other. Of note, however, event rates were very low in both groups when only 1 stent was implanted or the total length of stents was limited. Conversely, by multivariate analysis, the longer the lesion and the greater the number and length of stents implanted, the higher the event rate with both protection devices. Periprocedural adverse event rates were also increased in thrombotic lesions and degenerated vein grafts. Clearly, adjunctive therapies in addition to distal protection devices are required to additionally reduce the high adverse event rates after PCI in complex SVG lesions. Future design enhancements are likely to additionally improve outcomes with both devices. As previously reported, lack of vessel wall apposition with the FilterWire EX loop may occur and allow embolic debris to bypass the filter. 7 This phenomenon may be reduced by paying close attention to loop apposition in orthogonal views and has been eliminated with the next generation FilterWire EZ device, in which the collection apparatus moves independently from the guide wire shaft. The EZ device is also lower profile ( 3F) and more flexible, which would be expected to facilitate passage in tortuous vessels and crossing of tight lesions. The GuardWire has also been improved, however, with the crossing profile of the GuardWire Plus reduced to inches ( 2.3F) and with a simpler-to-use MicroSeal adapter and smaller Export catheter. The results of this trial apply only to the application studied, ie, distal protection during PCI of diseased SVGs. Whether filter-based catheters or balloon occlusion and aspiration systems are preferred in other clinical settings or vascular territories, such as during neurovascular intervention 11,12 or primary angioplasty for acute MI, 13 will require separate randomized trials to determine. Finally, additional comparative investigations will also be required to establish whether other filter-based distal protection catheters perform equally well, better, or worse than the FilterWire EX device. Clinical Implications Distal protection with the FilterWire EX system may be safely used as an adjunct to PCI of diseased SVGs and, compared with distal protection with the GuardWire balloon occlusion and aspiration system, results in similar rates of MACE at 30 days. Periprocedural adverse outcomes still occur in 10% of patients, however, emphasizing the need for complementary device-based innovations and new pharmacologic regimens to additionally enhance the safety of intervention in these high-risk patients. References 1. de Feyter PJ, van Suylen R-J, dejaegere PPT, et al. Balloon angioplasty for the treatment of lesions in saphenous vein bypass grafts. J Am Coll Cardiol. 1993;21: Holmes DR, Topol EJ, Califf RM, et al. A multicenter, randomized trial of coronary angioplasty versus directional atherectomy for patients with saphenous vein bypass graft lesions. Circulation. 1995;91: Hong MK, Mehran R, Dangas G, et al. Creatine kinase-mb enzyme elevation following successful saphenous vein graft intervention is associated with late mortality. Circulation. 1999;100: Hong MK, Mehran R, Dangas G, et al. Are we making progress with percutaneous saphenous vein graft treatment? A comparison of 1990 to 1994 and 1995 to 1998 results. J Am Coll Cardiol. 2001;38: Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation. 2002;105: Grube E, Gerckens U, Yeung AC, et al. Prevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection. Circulation. 2001;104: Stone GW, Rogers C, Ramee S, et al. Distal filter protection during saphenous vein graft stenting: technical and clinical correlates of efficacy. J Am Coll Cardiol. 2002;40: Grube E, Schofer J, Webb J, et al. Evaluation of a balloon occlusion and aspiration system for protection from distal embolization during stenting in saphenous vein grafts. Am J Cardiol. 2002;89: Lansky A, Popma J. Qualitative and quantitative angiography. In: Topol E, ed. Textbook of Interventional Cardiology. Philadelphia, Pa: WB Saunders; 1999: Blackwelder WC. Proving the null hypothesis in clinical trials. Control Clin Trials. 1982;3: Al-Mubarak N, Roubin GS, Vitek JV, et al. Effect of the distal-balloon protection system on microembolization during carotid stenting. Circulation. 2001;104: Grube E, Colombo A, Hauptmann A, et al. Multicenter experience with a novel distal protection filter during carotid artery stent implantation. Catheter Cardiovasc Interv. 2003;58: Wang HJ, Kao HL, Liau CS, et al. Export aspiration catheter thrombosuction before actual angioplasty in primary coronary intervention for acute myocardial infarction. Catheter Cardiovasc Interv. 2002;57:

Randomized Evaluation of the TriActiv Balloon-Protection Flush and Extraction System for the Treatment of Saphenous Vein Graft Disease

Randomized Evaluation of the TriActiv Balloon-Protection Flush and Extraction System for the Treatment of Saphenous Vein Graft Disease Journal of the American College of Cardiology Vol. 46, No. 9, 2005 2005 by the American College of Cardiology Foundation ISSN 0735-1097/05/$30.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2005.06.073

More information

Correlates of Adverse Events During Saphenous Vein Graft Intervention With Distal Embolic Protection

Correlates of Adverse Events During Saphenous Vein Graft Intervention With Distal Embolic Protection JACC: CARDIOVASCULAR INTERVENTIONS VOL. 1, NO. 2, 2008 2008 BY THE AMERICAN COLLEGE OF CARDIOLOGY FOUNDATION ISSN 1936-8798/08/$34.00 PUBLISHED BY ELSEVIER INC. DOI: 10.1016/j.jcin.2008.01.002 Correlates

More information

Treatment of Saphenous Vein Bypass Grafts With Ultrasound Thrombolysis. A Randomized Study (ATLAS)

Treatment of Saphenous Vein Bypass Grafts With Ultrasound Thrombolysis. A Randomized Study (ATLAS) Treatment of Saphenous Vein Bypass Grafts With Ultrasound Thrombolysis A Randomized Study (ATLAS) Mandeep Singh, MD; Uri Rosenschein, MD; Kalon K.L. Ho, MD; Peter B. Berger, MD; Richard Kuntz, MD; David

More information

CASE REPORTS: Filters to Prevent Distal Embolization during Coronary Artery Stenting: The Risk of Mousetrap

CASE REPORTS: Filters to Prevent Distal Embolization during Coronary Artery Stenting: The Risk of Mousetrap Page 1 / 5 CASE REPORTS: Filters to Prevent Distal Embolization during Coronary Artery Stenting: The Risk of Mousetrap - Ugo Limbruno, MD, Alberto Genovesi Ebert, MD, Michele Galli, MD We describe a case

More information

Clinical research Interventional cardiology

Clinical research Interventional cardiology European Heart Journal (2006) 27, 920 928 doi:10.1093/eurheartj/ehi736 Clinical research Interventional cardiology Platelet glycoprotein receptor inhibition as adjunctive treatment during saphenous vein

More information

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial Myeong-Ki Hong, MD. PhD on behalf of the IVUS-XPL trial investigators

More information

Are We Making Progress With Percutaneous Saphenous Vein Graft Treatment? A Comparison of 1990 to 1994 and 1995 to 1998 Results

Are We Making Progress With Percutaneous Saphenous Vein Graft Treatment? A Comparison of 1990 to 1994 and 1995 to 1998 Results Journal of the American College of Cardiology Vol. 38, No. 1, 2001 2001 by the American College of Cardiology ISSN 0735-1097/01/$20.00 Published by Elsevier Science Inc. PII S0735-1097(01)01324-9 Are We

More information

LM stenting - Cypher

LM stenting - Cypher LM stenting - Cypher Left main stenting with BMS Since 1995 Issues in BMS era AMC Restenosis and TLR (%) 3 27 TLR P=.282 Restenosis P=.71 28 2 1 15 12 Ostium 5 4 Shaft Bifurcation Left main stenting with

More information

PROMUS Element Experience In AMC

PROMUS Element Experience In AMC Promus Element Luncheon Symposium: PROMUS Element Experience In AMC Jung-Min Ahn, MD. University of Ulsan College of Medicine, Heart Institute, Asan Medical Center, Seoul, Korea PROMUS Element Clinical

More information

Results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies

Results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies Intracoronary Radiation Therapy Improves the Clinical and Angiographic Outcomes of Diffuse In-Stent Restenotic Lesions Results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions

More information

Keywords: reperfusion coronary bypass surgery primary angioplasty. Article: INTRODUCITON

Keywords: reperfusion coronary bypass surgery primary angioplasty. Article: INTRODUCITON Poor long-term patient and graft survival after primary percutaneous coronary intervention for acute myocardial infarction due to saphenous vein graft occlusion By: Bruce R. Brodie, Debra S. VerSteeg,

More information

A Randomized Comparison of Clopidogrel and Aspirin Versus Ticlopidine and Aspirin After the Placement of Coronary Artery Stents

A Randomized Comparison of Clopidogrel and Aspirin Versus Ticlopidine and Aspirin After the Placement of Coronary Artery Stents Journal of the American College of Cardiology Vol. 41, No. 6, 2003 2003 by the American College of Cardiology Foundation ISSN 0735-1097/03/$30.00 Published by Elsevier Science Inc. doi:10.1016/s0735-1097(02)02974-1

More information

Percutaneous Coronary Interventions Without On-site Cardiac Surgery

Percutaneous Coronary Interventions Without On-site Cardiac Surgery Percutaneous Coronary Interventions Without On-site Cardiac Surgery Hassan Al Zammar, MD,FESC Consultant & Interventional Cardiologist Head of Cardiology Department European Gaza Hospital Palestine European

More information

The MAIN-COMPARE Study

The MAIN-COMPARE Study Long-Term Outcomes of Coronary Stent Implantation versus Bypass Surgery for the Treatment of Unprotected Left Main Coronary Artery Disease Revascularization for Unprotected Left MAIN Coronary Artery Stenosis:

More information

Periprocedural Myocardial Infarction and Clinical Outcome In Bifurcation Lesion

Periprocedural Myocardial Infarction and Clinical Outcome In Bifurcation Lesion Periprocedural Myocardial Infarction and Clinical Outcome In Bifurcation Lesion Hyeon-Cheol Gwon Cardiac and Vascular Center Samsung Medical Center Sungkyunkwan University School of Medicine Dr. Hyeon-Cheol

More information

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System Volume 1, Issue 1 Case Report Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System Robert F. Riley * and Bill Lombardi University of Washington Medical Center, Division

More information

The grey zone of coronary interventions: Degenerated saphenous vein grafts

The grey zone of coronary interventions: Degenerated saphenous vein grafts PCI: procedural complications August 26: 14:00 15:30 The grey zone of coronary interventions: Degenerated saphenous vein grafts Prof. Dr. M. Haude Städtische Kliniken Neuss Lukaskrankenhaus GmbH Declaration

More information

Journal of the American College of Cardiology Vol. 35, No. 4, by the American College of Cardiology ISSN /00/$20.

Journal of the American College of Cardiology Vol. 35, No. 4, by the American College of Cardiology ISSN /00/$20. Journal of the American College of Cardiology Vol. 35, No. 4, 2000 2000 by the American College of Cardiology ISSN 0735-1097/00/$20.00 Published by Elsevier Science Inc. PII S0735-1097(99)00639-7 Immediate

More information

TCTAP Upendra Kaul MD,DM,FACC,FSCAI,FAMS,FCSI

TCTAP Upendra Kaul MD,DM,FACC,FSCAI,FAMS,FCSI Indian TUXEDO Trial In Medically Treated Diabetics Upendra Kaul MD,DM,FACC,FSCAI,FAMS,FCSI Executive Director and Dean Escorts Heart Institute & Medical Research Center and Fortis Hospitals, New Delhi

More information

Acute Myocardial Infarction. Willis E. Godin D.O., FACC

Acute Myocardial Infarction. Willis E. Godin D.O., FACC Acute Myocardial Infarction Willis E. Godin D.O., FACC Acute Myocardial Infarction Definition: Decreased delivery of oxygen and nutrients to the myocardium Myocardial tissue necrosis causing irreparable

More information

Acute Myocardial Infarction

Acute Myocardial Infarction Acute Myocardial Infarction Hafeza Shaikh, DO, FACC, RPVI Lourdes Cardiology Services Asst.Program Director, Cardiology Fellowship Associate Professor, ROWAN-SOM Acute Myocardial Infarction Definition:

More information

Abstract Background: Methods: Results: Conclusions:

Abstract Background: Methods: Results: Conclusions: Two-Year Clinical and Angiographic Outcomes of Overlapping Sirolimusversus Paclitaxel- Eluting Stents in the Treatment of Diffuse Long Coronary Lesions Kang-Yin Chen 1,2, Seung-Woon Rha 1, Yong-Jian Li

More information

SVG Stenting without Distal Protection Device:

SVG Stenting without Distal Protection Device: SVG Stenting without Distal Protection Device: My Experience Chetan P Shah, MD,DM,FACC,FACP Lilavati Hospital Fortis Hospital Kohinoor Hospital Kikabhai Premchand Cardiac Institute Zynova Heart Hospital

More information

Strategies for PCI of SVG

Strategies for PCI of SVG Strategies for PCI of SVG Ron Waksman, MD, FACC Augusto Pichard, MD, FACC Washington Hospital Center, Washington DC OPTIONS FOR IMPROVED OUTCOMES IN SVG PCI Direct Stenting Thrombus Management Embolic

More information

Case Report Rheolytic Thrombectomy Combined with a Protective Filter and Platelet Glycoprotein IIb/IIIa Receptor Inhibitors in Rescue Angioplasty

Case Report Rheolytic Thrombectomy Combined with a Protective Filter and Platelet Glycoprotein IIb/IIIa Receptor Inhibitors in Rescue Angioplasty Hell J Cardiol 46: 430-434, 2005 Case Report Rheolytic Thrombectomy Combined with a Protective Filter and Platelet Glycoprotein IIb/IIIa Receptor Inhibitors in Rescue Angioplasty PETROS S. DARDAS, NIKOS

More information

Clinical Investigations

Clinical Investigations Clinical Investigations Clinical Outcomes for Single Stent and Multiple Stents in Contemporary Practice Qiao Shu Bin, MD; Liu Sheng Wen, MD; Xu Bo, BS; Chen Jue, MD; Liu Hai Bo, MD; Yang Yue Jin, MD; Chen

More information

ARMYDA-RECAPTURE (Atorvastatin for Reduction of MYocardial Damage during Angioplasty) trial

ARMYDA-RECAPTURE (Atorvastatin for Reduction of MYocardial Damage during Angioplasty) trial ARMYDA-RECAPTURE ( for Reduction of MYocardial Damage during Angioplasty) trial Prospective, multicenter, randomized, double blind trial investigating efficacy of atorvastatin reload in patients on chronic

More information

Coronary Stenting with MGuard: First-In-Man Trial

Coronary Stenting with MGuard: First-In-Man Trial Original Contribution Coronary Stenting with MGuard: First-In-Man Trial Edo Kaluski, MD, Karl Eugen Hauptmann, MD, * Ralf Müller, MD, Steve Tsai, MD, Marc Klapholz MD, * Eberhard Grube, MD ABSTRACT: MGuard

More information

For Personal Use. Copyright HMP 2013

For Personal Use. Copyright HMP 2013 Case Report J INVASIVE CARDIOL 2013;25(2):E39-E41 A Case With Successful Retrograde Stent Delivery via AC Branch for Tortuous Right Coronary Artery Yoshiki Uehara, MD, PhD, Mitsuyuki Shimizu, MD, PhD,

More information

CAROTID ARTERY ANGIOPLASTY

CAROTID ARTERY ANGIOPLASTY CAROTID ARTERY ANGIOPLASTY Coverage for services, procedures, medical devices and drugs are dependent upon benefit eligibility as outlined in the member's specific benefit plan. This Medical Coverage Guideline

More information

Journal of the American College of Cardiology Vol. 46, No. 5, by the American College of Cardiology Foundation ISSN /05/$30.

Journal of the American College of Cardiology Vol. 46, No. 5, by the American College of Cardiology Foundation ISSN /05/$30. Journal of the American College of Cardiology Vol. 46, No. 5, 2005 2005 by the American College of Cardiology Foundation ISSN 0735-1097/05/$30.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2005.06.009

More information

Link between effectiveness and cost data Costing was conducted prospectively on the same patient sample as that used in the effectiveness analysis.

Link between effectiveness and cost data Costing was conducted prospectively on the same patient sample as that used in the effectiveness analysis. Heparin after percutaneous intervention (HAPI): a prospective multicenter randomized trial of three heparin regimens after successful coronary intervention Rabah M, Mason D, Muller D W, Hundley R, Kugelmass

More information

Influence of Planned Six-Month Follow-Up Angiography on Late Outcome After Percutaneous Coronary Intervention A Randomized Study

Influence of Planned Six-Month Follow-Up Angiography on Late Outcome After Percutaneous Coronary Intervention A Randomized Study Journal of the American College of Cardiology Vol. 38, No. 4, 2001 2001 by the American College of Cardiology ISSN 0735-1097/01/$20.00 Published by Elsevier Science Inc. PII S0735-1097(01)01476-0 Influence

More information

Intra-Procedural Stent Thrombosis

Intra-Procedural Stent Thrombosis JACC: CARDIOVASCULAR INTERVENTIONS VOL. 6, NO. 1, 2013 2013 BY THE AMERICAN COLLEGE OF CARDIOLOGY FOUNDATION ISSN 1936-8798/$36.00 PUBLISHED BY ELSEVIER INC. http://dx.doi.org/10.1016/j.jcin.2012.08.018

More information

A Pooled Analysis of Five Randomized Clinical Trials

A Pooled Analysis of Five Randomized Clinical Trials Lack of Benefit From Intravenous latelet Glycoprotein IIb/IIIa Receptor Inhibition as Adjunctive Treatment for ercutaneous Interventions of Aortocoronary Bypass Grafts A ooled Analysis of Five Randomized

More information

Journal of the American College of Cardiology Vol. 55, No. 9, by the American College of Cardiology Foundation ISSN /10/$36.

Journal of the American College of Cardiology Vol. 55, No. 9, by the American College of Cardiology Foundation ISSN /10/$36. Journal of the American College of Cardiology Vol. 55, No. 9, 2010 2010 by the American College of Cardiology Foundation ISSN 0735-1097/10/$36.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2009.09.052

More information

Distal Protection in Native Coronary Arteries During Primary Angioplasty in Acute Myocardial Infarction: Single-Center Experience

Distal Protection in Native Coronary Arteries During Primary Angioplasty in Acute Myocardial Infarction: Single-Center Experience Catheterization and Cardiovascular Interventions 60:152 158 (2003) Distal Protection in Native Coronary Arteries During Primary Angioplasty in Acute Myocardial Infarction: Single-Center Experience Pedro

More information

Le# main treatment with Stentys stent. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

Le# main treatment with Stentys stent. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy Le# main treatment with Stentys stent Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy Disclosure Statement of Financial Interest I, Carlo Briguori DO NOT have a financial interest/ arrangement

More information

Are Asian Patients Different? - Updates Of Biomatrix Experience In Regional Settings: BEACON II (3 Yr F up) &

Are Asian Patients Different? - Updates Of Biomatrix Experience In Regional Settings: BEACON II (3 Yr F up) & Are Asian Patients Different? - Updates Of Biomatrix Experience In Regional Settings: BEACON II (3 Yr F up) & Biomatrix TM Single Center Experience (Indonesia)(Final 5 Yr F up) T. Santoso University of

More information

Three-Year Clinical Outcomes with Everolimus-Eluting Bioresorbable Scaffolds: Results from the Randomized ABSORB III Trial Stephen G.

Three-Year Clinical Outcomes with Everolimus-Eluting Bioresorbable Scaffolds: Results from the Randomized ABSORB III Trial Stephen G. Three-Year Clinical Outcomes with Everolimus-Eluting Bioresorbable Scaffolds: Results from the Randomized ABSORB III Trial Stephen G. Ellis MD Dean J. Kereiakes MD and Gregg W. Stone MD for the ABSORB

More information

How to Choose Among Carotid Embolic Protection Devices?

How to Choose Among Carotid Embolic Protection Devices? How to Choose Among Carotid Embolic Protection Devices? James P. Zidar, M.D., F.A.C.C., F.S.C.A.I. Associate Professor of Medicine Duke University Medical Center Director, Cardiovascular Services Duke

More information

Coronary drug-eluting stents (DES) were first approved

Coronary drug-eluting stents (DES) were first approved Thrombosis in Coronary Drug-Eluting Stents Report From the Meeting of the Circulatory System Medical Devices Advisory Panel of the Food and Drug Administration Center for Devices and Radiologic Health,

More information

FFR vs. icecg in Coronary Bifurcations (FIESTA) - preliminary results. Dobrin Vassilev MD, PhD National Heart Hospital Sofia, Bulgaria

FFR vs. icecg in Coronary Bifurcations (FIESTA) - preliminary results. Dobrin Vassilev MD, PhD National Heart Hospital Sofia, Bulgaria FFR vs. icecg in Coronary Bifurcations (FIESTA) - preliminary results Dobrin Vassilev MD, PhD National Heart Hospital Sofia, Bulgaria I would like to express my personal gratitude to Dr. BK Koo for opening

More information

STENTYS for Le, Main Sten2ng. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

STENTYS for Le, Main Sten2ng. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy STENTYS for Le, Main Sten2ng Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy Disclosure Statement of Financial Interest I, Carlo Briguori DO NOT have a financial interest/ arrangement or affilia2on

More information

EXCEL vs. NOBLE: How to Treat Left Main Disease in 2017 AATS International Cardiovascular Symposium December 8-9, 2017

EXCEL vs. NOBLE: How to Treat Left Main Disease in 2017 AATS International Cardiovascular Symposium December 8-9, 2017 EXCEL vs. NOBLE: How to Treat Left Main Disease in 2017 AATS International Cardiovascular Symposium December 8-9, 2017 Igor F. Palacios, MD Director of Interventional Cardiology Professor of Medicine Massachusetts

More information

Bifurcation stenting with BVS

Bifurcation stenting with BVS Bifurcation stenting with BVS Breaking the limits or just breaking the struts? Maciej Lesiak Department of Cardiology University Hospital in Poznan, Poland Disclosure Speaker s name: Maciej Lesiak I have

More information

Journal of the American College of Cardiology Vol. 38, No. 3, by the American College of Cardiology ISSN /01/$20.

Journal of the American College of Cardiology Vol. 38, No. 3, by the American College of Cardiology ISSN /01/$20. Journal of the American College of Cardiology Vol. 38, No. 3, 2001 2001 by the American College of Cardiology ISSN 0735-1097/01/$20.00 Published by Elsevier Science Inc. PII S0735-1097(01)01423-1 Effect

More information

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER Page 1 of 5 ASPIRATION CATHETER Carefully read all instructions prior to use, observe all warnings and precautions noted throughout these instructions. Failure to do so may result in complications. STERILE.

More information

Prevention of Coronary Stent Thrombosis and Restenosis

Prevention of Coronary Stent Thrombosis and Restenosis Prevention of Coronary Stent Thrombosis and Restenosis Seong-Wook Park, MD, PhD, FACC Division of Cardiology, Asan Medical Center University of Ulsan College of Medicine, Seoul, Korea 9/12/03 Coronary

More information

Supplementary Table S1: Proportion of missing values presents in the original dataset

Supplementary Table S1: Proportion of missing values presents in the original dataset Supplementary Table S1: Proportion of missing values presents in the original dataset Variable Included (%) Missing (%) Age 89067 (100.0) 0 (0.0) Gender 89067 (100.0) 0 (0.0) Smoking status 80706 (90.6)

More information

Revived indications for thrombus aspiration during primary PCI: Unanswered questions after TAPAS

Revived indications for thrombus aspiration during primary PCI: Unanswered questions after TAPAS Revived indications for thrombus aspiration during primary PCI: Unanswered questions after TAPAS Gregg W. Stone MD Columbia University Medical Center Cardiovascular Research Foundation Disclosures Gregg

More information

FFR-guided Jailed Side Branch Intervention

FFR-guided Jailed Side Branch Intervention FFR-guided Jailed Side Branch Intervention - Pressure wire in Bifurcation lesions - Bon-Kwon Koo, MD, PhD Seoul National University Hospital, Seoul, Korea Bifurcation Lesions Bifurcation Lesions Still

More information

Revascularization after Drug-Eluting Stent Implantation or Coronary Artery Bypass Surgery for Multivessel Coronary Disease

Revascularization after Drug-Eluting Stent Implantation or Coronary Artery Bypass Surgery for Multivessel Coronary Disease Impact of Angiographic Complete Revascularization after Drug-Eluting Stent Implantation or Coronary Artery Bypass Surgery for Multivessel Coronary Disease Young-Hak Kim, Duk-Woo Park, Jong-Young Lee, Won-Jang

More information

Importance of the third arterial graft in multiple arterial grafting strategies

Importance of the third arterial graft in multiple arterial grafting strategies Research Highlight Importance of the third arterial graft in multiple arterial grafting strategies David Glineur Department of Cardiovascular Surgery, Cliniques St Luc, Bouge and the Department of Cardiovascular

More information

Why I m afraid of occlusive devices

Why I m afraid of occlusive devices Why I m afraid of occlusive devices Cannes 28.06.2008 Carlo Cernetti Cardiology Department Mirano (Venice) MEET 2008 CANNES I HAVE NOT FINACIAL INTEREST/ARRANGEMENT OR AFFILIATION CONFLICT Obstructive

More information

Ischemic Postconditioning During Primary Percutaneous Coronary Intervention Mechanisms and Clinical Application Jian Liu, MD FACC FESC FSCAI Chief Phy

Ischemic Postconditioning During Primary Percutaneous Coronary Intervention Mechanisms and Clinical Application Jian Liu, MD FACC FESC FSCAI Chief Phy Ischemic Postconditioning During Primary Percutaneous Coronary Intervention Mechanisms and Clinical Application Jian Liu, MD FACC FESC FSCAI Chief Physician, Professor of Medicine Department of Cardiology,

More information

Safety and Efficacy of Angioplasty with Intracoronary Stenting in Patients with Unstable Coronary Syndromes. Comparison with Stable Coronary Syndromes

Safety and Efficacy of Angioplasty with Intracoronary Stenting in Patients with Unstable Coronary Syndromes. Comparison with Stable Coronary Syndromes Original Article Safety and Efficacy of Angioplasty with Intracoronary Stenting in Patients with Unstable Coronary Syndromes. Comparison with Stable Coronary Syndromes Luís C. L. Correia, José Carlos Brito,

More information

Safety of Single- Versus Multi-vessel Angioplasty for Patients with AMI and Multi-vessel CAD

Safety of Single- Versus Multi-vessel Angioplasty for Patients with AMI and Multi-vessel CAD Safety of Single- Versus Multi-vessel Angioplasty for Patients with AMI and Multi-vessel CAD Mun K. Hong, MD Associate Professor of Medicine Director, Cardiovascular Intervention and Research Weill Cornell

More information

Contemporary Percutaneous Coronary Intervention Versus Balloon Angioplasty for Multivessel Coronary Artery Disease

Contemporary Percutaneous Coronary Intervention Versus Balloon Angioplasty for Multivessel Coronary Artery Disease Contemporary Percutaneous Coronary Intervention Versus Balloon Angioplasty for Multivessel Coronary Artery Disease A Comparison of the National Heart, Lung and Blood Institute Dynamic Registry and the

More information

Unprotected LM intervention

Unprotected LM intervention Unprotected LM intervention Guideline for COMBAT Seung-Jung Park, MD, PhD Professor of Internal Medicine, Seoul, Korea Current Recommendation for unprotected LMCA Stenosis Class IIb C in ESC guideline

More information

Lessons learned From The National PCI Registry

Lessons learned From The National PCI Registry Lessons learned From The National PCI Registry w a v e On Behalf of The Publication Committee of the National PCI Registry Objectives & Anticipated Achievements To determine the epidemiology of patients

More information

We Catch. What Others Miss

We Catch. What Others Miss We Catch What Others Miss GORE Embolic Filter Diamond Frame Circumferential Filter Attachment eptfe Filter Media with 100-Micron Pores and Hydrophilic Heparin Coating Diamond Frame designed to enhance

More information

C. Thrombus burden according to TIMI thrombus grading system

C. Thrombus burden according to TIMI thrombus grading system The Supplementary appendix A. TIMI flow grading system B. Coronary lesions classification C. Thrombus burden according to TIMI thrombus grading system D. TIMI frame count E. Myocardial blush grade A. TIMI

More information

The New England Journal of Medicine INTRAVASCULAR GAMMA RADIATION FOR IN-STENT RESTENOSIS IN SAPHENOUS-VEIN BYPASS GRAFTS

The New England Journal of Medicine INTRAVASCULAR GAMMA RADIATION FOR IN-STENT RESTENOSIS IN SAPHENOUS-VEIN BYPASS GRAFTS INTRAVASCULAR GAMMA RADIATION FOR IN-STENT RESTENOSIS IN SAPHENOUS-VEIN BYPASS GRAFTS RON WAKSMAN, M.D., ANDREW E. AJANI, M.D., R. LARRY WHITE, M.D., ROSANNA C. CHAN, M.D., LOWELL F. SATLER, M.D., KENNETH

More information

Count Down to COMBAT

Count Down to COMBAT Count Down to COMBAT Randomized COMparison of Bypass Surgery versus AngioplasTy using Sirolimus-Eluting Stent in Patients with Left Main Coronary Artery Disease Roxana Mehran, MD Associate Professor of

More information

Interventional Cardiology

Interventional Cardiology Interventional Cardiology Saphenous Vein Graft Stenting and Major Adverse Cardiac Events A Predictive Model Derived From a Pooled Analysis of 3958 Patients Alanna Coolong, MD, MSc; Donald S. Baim, MD;

More information

COMBAT- Revised Protocol

COMBAT- Revised Protocol COMBAT- Revised Protocol Randomized COMparison of Bypass Surgery versus AngioplasTy using Sirolimus-Eluting Stent in Patients with Left Main Coronary Artery Disease Roxana Mehran, MD Associate Professor

More information

CPT Code Details

CPT Code Details CPT Code 93572 Details Code Descriptor Intravascular Doppler velocity and/or pressure derived coronary flow reserve measurement (coronary vessel or graft) during coronary angiography including pharmacologically

More information

SKG Congress, 2015 EVOLVE II. Stephan Windecker

SKG Congress, 2015 EVOLVE II. Stephan Windecker SKG Congress, 2015 EVOLVE II Stephan Windecker Department of Cardiology Swiss Cardiovascular Center and Clinical Trials Unit Bern Bern University Hospital, Switzerland BIODEGRADABLE POLYMER DES Stefanini,

More information

Modeling and Risk Prediction in the Current Era of Interventional Cardiology

Modeling and Risk Prediction in the Current Era of Interventional Cardiology Modeling and Risk Prediction in the Current Era of Interventional Cardiology A Report From the National Heart, Lung, and Blood Institute Dynamic Registry David R. Holmes, MD; Faith Selzer, PhD; Janet M.

More information

TOBA II 12-Month Results Tack Optimized Balloon Angioplasty

TOBA II 12-Month Results Tack Optimized Balloon Angioplasty TOBA II 12-Month Results Tack Optimized Balloon Angioplasty William Gray, MD System Chief, Cardiovascular Division Main Line Health, Philadelphia, PA Dissection: The Primary Mechanism of Angioplasty Lesions

More information

PCI for Left Anterior Descending Artery Ostial Stenosis

PCI for Left Anterior Descending Artery Ostial Stenosis PCI for Left Anterior Descending Artery Ostial Stenosis Why do you hesitate PCI for LAD ostial stenosis? LAD Ostial Lesion Limitations of PCI High elastic recoil Involvement of the distal left main coronary

More information

Safety and Efficacy of Coronary Stent Implantation. Acute and Six Month Outcomes of 1,126 Consecutive Patients Treated in 1996 and 1997

Safety and Efficacy of Coronary Stent Implantation. Acute and Six Month Outcomes of 1,126 Consecutive Patients Treated in 1996 and 1997 Original Article Safety and Efficacy of Coronary Stent Implantation. Acute and Six Month Outcomes of 1,126 Consecutive Patients Treated in 1996 and 1997 Luiz Alberto Mattos, Ibraim Pinto, Alexandre Abizaid,

More information

Final Clinical and Angiographic Results From a Nationwide Registry of FIREBIRD Sirolimus- Eluting Stent: Firebird In China (FIC) Registry (PI R. Gao)

Final Clinical and Angiographic Results From a Nationwide Registry of FIREBIRD Sirolimus- Eluting Stent: Firebird In China (FIC) Registry (PI R. Gao) The Microport FIREBIRD Polymer-based Sirolimus- Eluting Stent Clinical Trial Program Update: The FIC and FIREMAN Registries Junbo Ge, MD, FACC, FESC, FSCAI On behalf of Runlin Gao (FIC PI) and Haichang

More information

Hypothesis: When compared to conventional balloon angioplasty, cryoplasty post-dilation decreases the risk of SFA nses in-stent restenosis

Hypothesis: When compared to conventional balloon angioplasty, cryoplasty post-dilation decreases the risk of SFA nses in-stent restenosis Cryoplasty or Conventional Balloon Post-dilation of Nitinol Stents For Revascularization of Peripheral Arterial Segments Background: Diabetes mellitus is associated with increased risk of in-stent restenosis

More information

Coronary angiography and PCI

Coronary angiography and PCI Coronary arteries Coronary angiography and PCI Samo Granda, Franjo Naji Department of Cardiology Clinical department of internal medicine University clinical centre Maribor Coronary arteries Atherosclerosis

More information

DESolve NX Trial Clinical and Imaging Results

DESolve NX Trial Clinical and Imaging Results DESolve NX Trial Clinical and Imaging Results Alexandre Abizaid, MD, PhD, Instituto Dante Pazzanese, Sao Paulo, Brazil On behalf of the DESolve Nx Trial Investigators Please refer to the TCT2014 App or

More information

Coronary Artery Perforation Angioplasty Summit Seoul April 30, 2005

Coronary Artery Perforation Angioplasty Summit Seoul April 30, 2005 Coronary Artery Perforation Angioplasty Summit Seoul April 30, 2005 James R. Margolis, M.D. Miami International Cardiology Consultants Miami, Florida USA Introduction In the stent era, coronary artery

More information

DECISION-CTO. Optimal Medical Therapy With or Without Stenting For Coronary Chronic Total Occlusion. Seung-Jung Park, MD., PhD.

DECISION-CTO. Optimal Medical Therapy With or Without Stenting For Coronary Chronic Total Occlusion. Seung-Jung Park, MD., PhD. DECISION-CTO Optimal Medical Therapy With or Without Stenting For Coronary Chronic Total Occlusion Seung-Jung Park, MD., PhD. Heart Institute, University of Ulsan College of Medicine Asan Medical Center,

More information

Angiographic and Intravascular Ultrasound Predictors of In-Stent Restenosis

Angiographic and Intravascular Ultrasound Predictors of In-Stent Restenosis 1630 JACC Vol. 32, No. 6 Angiographic and Intravascular Ultrasound Predictors of In-Stent Restenosis SHUNJI KASAOKA, MD, JONATHAN M. TOBIS, MD, FACC, TATSURO AKIYAMA, MD,* BERNHARD REIMERS, MD,* CARLO

More information

RECOMMENDED INSTRUCTIONS FOR USE

RECOMMENDED INSTRUCTIONS FOR USE Rapid Exchange PTCA Dilatation Catheter RECOMMENDED INSTRUCTIONS FOR USE Available in diameters 1.25mm to 4.5mm and in lengths 09mm to 40mm Caution: This device should be used only by physicians trained

More information

DISRUPT CAD. Todd J. Brinton, MD Clinical Associate Professor of Medicine Adjunct Professor of Bioengineering Stanford University

DISRUPT CAD. Todd J. Brinton, MD Clinical Associate Professor of Medicine Adjunct Professor of Bioengineering Stanford University DISRUPT CAD A multicenter, prospective, single-arm study of percutaneous Lithoplasty prior to stent implantation in heavily calcified coronary lesions Todd J. Brinton, MD Clinical Associate Professor of

More information

Clinical Investigations

Clinical Investigations Clinical Investigations Risk Factors of Cardiac Troponin T Elevation in Patients with Stable Coronary Artery Disease After Elective Coronary Drug-Eluting Stent Implantation Zhang-Wei Chen, MD; Ju-Ying

More information

Impact of Clinical Syndrome Acuity on the Differential Response to 2 Glycoprotein IIb/IIIa Inhibitors in Patients Undergoing Coronary Stenting

Impact of Clinical Syndrome Acuity on the Differential Response to 2 Glycoprotein IIb/IIIa Inhibitors in Patients Undergoing Coronary Stenting Impact of Clinical Syndrome Acuity on the Differential Response to 2 Glycoprotein IIb/IIIa Inhibitors in Patients Undergoing Coronary Stenting The TARGET Trial* Gregg W. Stone, MD; David J. Moliterno,

More information

PrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!!

PrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!! PrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!! Prof Piotr Pieniazek MD PhD Jagiellonian University Institute of Cardiology, John Paul II Hospital Krakow, Poland

More information

Clopidogrel Date: 15 July 2008

Clopidogrel Date: 15 July 2008 These results are supplied for informational purposes only. Prescribing decisions should be made based on the approved package insert in the country of prescription Sponsor/company: sanofi-aventis ClinicalTrials.gov

More information

Cafri C; Zahger D; Rosenshtein G, Kleshian I; Ilia R

Cafri C; Zahger D; Rosenshtein G, Kleshian I; Ilia R Primary Percutaneous Coronary Intervention and Large Thrombus Burden Lesio: A Questionable Impact of Mesh Covered Stent on the Frequency of No Reflow Cafri C; Zahger D; Rosehtein G, Kleshian I; Ilia R

More information

ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions

ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions Julinda Mehilli, MD Deutsches Herzzentrum Technische Universität Munich Germany ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions Background Left main

More information

What is the Optimal Triple Anti-platelet Therapy Duration in Patients with Acute Myocardial Infarction Undergoing Drug-eluting Stents Implantation?

What is the Optimal Triple Anti-platelet Therapy Duration in Patients with Acute Myocardial Infarction Undergoing Drug-eluting Stents Implantation? What is the Optimal Triple Anti-platelet Therapy Duration in Patients with Acute Myocardial Infarction Undergoing Drug-eluting Stents Implantation? Keun-Ho Park, Myung Ho Jeong, Min Goo Lee, Jum Suk Ko,

More information

Direct Thrombin Inhibitors for PCI Pharmacology: Role of Bivalirudin in High-Risk PCI

Direct Thrombin Inhibitors for PCI Pharmacology: Role of Bivalirudin in High-Risk PCI Direct Thrombin Inhibitors for PCI Pharmacology: Role of Bivalirudin in High-Risk PCI Charles A. Simonton MD, FACC, FSCAI Sanger Clinic Medical Director Clinical Innovation and Research Carolinas Heart

More information

Δημήτριος Αγγοσράς, FETCS

Δημήτριος Αγγοσράς, FETCS ΣΕΜΙΝΑΡΙΟ ΟΜΑΔΩΝ ΕΡΓΑΣΙΑΣ Δημήτριος Αγγοσράς, FETCS Επίκοσρος Καθηγηηής Καρδιοτειροσργικής Ιαηρική Πανεπιζηημίοσ Αθηνών Πανεπιζηημιακό Γενικό Νοζοκομείο Αηηικόν Randomized Controlled Trials (RCTs) Why

More information

Comparison Of Primary Long Stenting Versus Primary Short Stenting For Long Femoropopliteal Artery Disease (PARADE)

Comparison Of Primary Long Stenting Versus Primary Short Stenting For Long Femoropopliteal Artery Disease (PARADE) Comparison Of Primary Long Stenting Versus Primary Short Stenting For Long Femoropopliteal Artery Disease (PARADE) Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

More information

PCI for Long Coronary Lesion

PCI for Long Coronary Lesion PCI for Long Coronary Lesion Shift of a General Idea with the Introduction of DES In the Bare Metal Stent Era Higher Restenosis Rate With Increasing Stent Length and Decreasing Stent Area Restenosis.6.4.2

More information

Adjunctive Stent Implantation Following Directional Coronary Atherectomy in Patients With Coronary Artery Disease

Adjunctive Stent Implantation Following Directional Coronary Atherectomy in Patients With Coronary Artery Disease JACC Vol. 32, No. 7 December 1998:1855 60 1855 Adjunctive Stent Implantation Following Directional Coronary Atherectomy in Patients With Coronary Artery Disease EZIO BRAMUCCI, MD,* LUIGI ANGOLI, MD,* PIERA

More information

FAME STUDY: 2-year Follow-Up & CLINICAL SUBGROUP ANALYSIS

FAME STUDY: 2-year Follow-Up & CLINICAL SUBGROUP ANALYSIS Coronary Physiology In The Cathlab FAME STUDY: 2-year Follow-Up & CLINICAL SUBGROUP ANALYSIS Educational Training Program ESC European Heart House april 7th 9th 2011 Nico H.J.Pijls, MD, PhD Catharina Hospital,

More information

EBC London 2013 Provisional SB stenting strategy with kissing balloon with Absorb

EBC London 2013 Provisional SB stenting strategy with kissing balloon with Absorb EBC London 2013 Provisional SB stenting strategy with kissing balloon with Absorb A. Medina Servicio de Cardiología Hospital Universitario de Gran Canaria Dr. Negrín Islas Canarias (Spain) Provisional

More information

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER Page 1 of 5 NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER STERILE. SINGLE USE ONLY. Sterilized with ethylene oxide gas. Non pyrogenic. Do not resterilize. Do not use opened or damaged packages.

More information

When Aspiration Thrombectomy Does Not Work? A A R O N W O N G N A T I O N A L H E A R T C E N T R E S I N G A P O R E

When Aspiration Thrombectomy Does Not Work? A A R O N W O N G N A T I O N A L H E A R T C E N T R E S I N G A P O R E When Aspiration Thrombectomy Does Not Work? A A R O N W O N G N A T I O N A L H E A R T C E N T R E S I N G A P O R E Thrombus in STEMI Over 70% of STEMI patients has angiographic evidence of thrombus

More information