We Catch. What Others Miss
|
|
- Dorothy Armstrong
- 6 years ago
- Views:
Transcription
1 We Catch What Others Miss
2 GORE Embolic Filter Diamond Frame Circumferential Filter Attachment eptfe Filter Media with 100-Micron Pores and Hydrophilic Heparin Coating
3 Diamond Frame designed to enhance wall apposition to improve filter efficiency. Circumferential Filter Attachment designed to limit the escape of debris between the frame and vessel wall while accommodating small landing zones with tight curves. eptfe Filter Media with 100-Micron Pores and Hydrophilic Heparin Coating along with proximal frame attachment provides large filter capacity and good flow through the filter. Trackability with torque response similar to bare wire. Access tight tortuous lesions.
4 IN VITRO EVALUATIONS * Filter Efficiency The ability to capture embolic debris is driven by a combination of filter frame vessel apposition, circumferential support of filter media and pore size the GORE Embolic Filter excels in all three. The GORE Embolic Filter maintains performance when deployed in tight curves that are representative of clinical anatomy. Pore Size (microns) GORE Embolic Filter 100 Boston Scientific FILTERWIRE EZ 110 Abbott RX ACCUNET 120 Cordis ANGIOGUARD RX 100 Covidien SPIDERFX Abbott Vascular EMBOSHIELD NAV Average capture efficiency and normalized pressure gradient increase with 143 μm particles (n = 10) Normalized Pressure Gradient Increase with 143 µm particles (%) Cordis 100 ANGIOGUARD Abbott RX ACCUNET RX Covidien SPIDERFX Abbott Vascular EMBOSHIELD NAV6 Boston Scientific FILTERWIRE EZ GORE Embolic Filter Capture Efficiency (%) * Siewiorek GM, Wholey MH, Finol EA. A comparative analysis of bench-top performance assessment of distal protection filters in transient flow conditions. Journal of Endovascular Therapy 2012;19(2):
5 Lesion Crossability TIP TRANSITIONS Smooth tip transition may reduce potential for embolization while crossing lesions. 3.2 Fr crossing profile is competitive with other devices. GORE Embolic Filter Boston Scientific FILTERWIRE EZ Abbott RX ACCUNET Cordis ANGIOGUARD RX Covidien SPIDERFX Abbott Vascular EMBOSHIELD NAV6 GORE Embolic Filter 0.014" Guidewire Nitinol frame Heparin-coated eptfe with 3 radiopaque filter bag markers Olive Floppy tip (radiopaque) Radiopaque Collar 3 cm Delivery Catheter 150 cm Wire Exit Port 30 cm 3.2 Fr (1.1 mm) Retrieval Catheter 150 cm Radiopaque Marker 4.8 Fr (1.6 mm) Wire Exit Port 3 mm 30 cm
6 Particles Missed by Commercially-Available Filters Recent Filter Efficiency Publication Highlights * Independent verification of internal filter efficiency video GORE Embolic Filter has the highest capture efficiency of the main embolic filters with the smallest particles GORE Embolic Filter demonstrates excellent flow rates and minimal pressure gradients Embolic Debris missed by GORE Embolic Filter Embolic Debris missed by Abbott RX ACCUNET Embolic Debris missed by Boston Scientific FILTERWIRE EZ Embolic Debris missed by Abbott Vascular EMBOSHIELD NAV6 Embolic Debris missed by Cordis ANGIOGUARD RX Embolic Debris missed by Covidien SPIDERFX * Siewiorek GM, Wholey MH, Finol EA. A comparative analysis of bench-top performance assessment of distal protection filters in transient flow conditions. Journal of Endovascular Therapy 2012;19(2):
7 Configurations Catalogue Number (US / Europe) Filter Diameter Unconstrained (mm) Reference Vessel Diameter Range (mm) Description GEF A / GEF E mm Filter on 185 cm Guidewire GEF A / GEF E mm Filter on 300 cm Guidewire GEF A / GEF E mm Filter on 185 cm Guidewire GEF A / GEF E mm Filter on 300 cm Guidewire Sizing Table Filter Diameter Unconstrained (mm) Reference Vessel Diameter Range (mm) Guiding Catheter / Sheath min ID 0.066" (1.67 mm) min ID 0.066" (1.67 mm) 6 Fr guide catheter and 5 Fr sheath compatible
8 W. L. Gore & Associates, Inc. Flagstaff, AZ (Asia Pacific) (Europe) (United States) (United States) goremedical.com INDICATIONS FOR USE IN THE US: The GORE Embolic Filter is indicated for use as a guidewire and embolic protection system to contain and remove embolic material during angioplasty and stenting procedures in carotid arteries with diameters between 2.5 and 5.5 mm. INDICATIONS FOR USE UNDER CE MARK: The GORE Embolic Filter is indicated for use as a guidewire and embolic protection system to contain and remove embolic material (thrombus / debris) during angioplasty and stenting procedures in coronary arteries, saphenous vein grafts, carotid arteries and peripheral arteries with reference diameters of 2.5 to 5.5 mm. Refer to Instructions for Use at goremedical.com for a complete list of contraindications, warnings and precautions, and adverse events. Products listed may not be available in all markets. ACCUNET, EMBOSHIELD, and NAV6 are trademarks of the Abbott Laboratories. FILTERWIRE EZ is a trademark of Boston Scientific Corporation. ANGIOGUARD RX is a trademark of Cordis Corporation. SPIDERFX is a trademark of Covidien. GORE, PERFORMANCE BY DESIGN, and designs are trademarks of W. L. Gore & Associates. 2006, , 2013 W. L. Gore & Associates, Inc. AQ4426-EN2 NOVEMBER 2013
How to Choose Among Carotid Embolic Protection Devices?
How to Choose Among Carotid Embolic Protection Devices? James P. Zidar, M.D., F.A.C.C., F.S.C.A.I. Associate Professor of Medicine Duke University Medical Center Director, Cardiovascular Services Duke
More informationFilters versus Occlusion Balloons during CAS Is there a clear preference?
Washington TCT 2005 Filters versus Occlusion Balloons during CAS Is there a clear preference? K. Mathias Department of Radiology Teaching Hospital of Dortmund - Germany Presenter Disclosure Information
More informationAll-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS
All-In-One Iliac Branch System PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS Exclusively Designed for Use in The GORE EXCLUDER Iliac Branch designed for the iliac branch, built from the same
More informationTHE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT
THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous
More informationCAROTID ARTERY ANGIOPLASTY
CAROTID ARTERY ANGIOPLASTY Coverage for services, procedures, medical devices and drugs are dependent upon benefit eligibility as outlined in the member's specific benefit plan. This Medical Coverage Guideline
More informationMAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES
MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES PUSHING BOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging
More informationThe Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES
The Art of Flow Restoration Japan s Recognized PCI Technology For Both Everyday and Complex CTO Cases* Manufactured by Kaneka Corporation, one of Japan s leading providers of interventional devices. Now
More informationIndications for use. Contraindications within the United States
Indications for use Indications within the United States The GORE TAG Thoracic Endoprosthesis is intended for endovascular repair of all lesions of the descending thoracic aorta, including: Isolated lesions
More informationDurable outcomes. Proven performance.
Durable outcomes. Proven performance. GORE EXCLUDER AAA Endoprosthesis GORE EXCLUDER Iliac Branch Endoprosthesis GORE EXCLUDER AAA Endoprosthesis The most-studied* EVAR stent graft designed for durable
More informationIssam D. Moussa, MD. Professor of Medicine Mayo Clinic College of Medicine Chair, Division of Cardiovascular Diseases Mayo Clinic Jacksonville, FL
Carotid Technologies and Protection Issam D. Moussa, MD Professor of Medicine Mayo Clinic College of Medicine Chair, Division of Cardiovascular Diseases Mayo Clinic Jacksonville, FL Disclosure Statement
More informationZenith Alpha T HORACIC ENDOVASCULAR GRAFT
Device description Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21181-EN-F Modular design The two-piece modular system allows the physician to customize a graft system to fit each
More informationINSTRUCTIONS FOR USE FOR: English
INSTRUCTIONS FOR USE FOR: English INSTRUCTIONS FOR USE FOR: Carefully read all instructions prior to use. Observe all warnings and precautions noted throughout these instructions. Failure to do so may
More informationNIRxcell CoCr Coronary Stent System
cordis.com/nirxcell NIRxcell CoCr Coronary Stent System Exceptional Outcomes by Design Exceptionally low TLR rate of 5.1 % at 9 months 1 Superior Deliverability and Crossability 2 Best-in-class Conformability
More informationSolitaire FR Revascularization Device
Solitaire FR Revascularization Device FEATURING PARAMETRIC DESIGN Restore. Retrieve. Revive. 5 Revolutionizing Mechanical Thrombectomy with Parametric Design Solitaire FR Device The Solitaire FR revascularization
More informationCarotid artery stents and embolic protection
Regulation of Carotid Artery Stents and Embolic Protection Devices in the United States A history of, and perspectives on, FDA regulation of carotid stents and associated embolic protection devices over
More informationMechanical Properties of the GORE TIGRIS Vascular Stent
Mechanical Properties of the GORE TIGRIS The nitinol frame makes it strong. The fluoropolymers make it flexible. Together, they make it unique. Purpose The association of target vessel restenosis with
More informationIntroduction What Causes Peripheral Vascular Disease? How Do Doctors Treat Peripheral Vascular Disease?... 9
Patient Information Table of Contents Introduction... 3 What is Peripheral Vascular Disease?... 5 What Are Some of the Symptoms of Peripheral Vascular Disease?... 7 What Causes Peripheral Vascular Disease?...
More informationCAROTID ARTERY ANGIOPLASTY
CAROTID ARTERY ANGIOPLASTY Non-Discrimination Statement and Multi-Language Interpreter Services information are located at the end of this document. Coverage for services, procedures, medical devices and
More informationNitinol biomedical devices: Design analysis
Biomedical Engineering Nitinol biomedical devices: Design analysis M. Conti Dipartimento di Meccanica Strutturale, Università degli Studi di Pavia, Italy micheleconti82@gmail.com http://www.unipv.it/dms/auricchio
More information1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER
Page 1 of 5 ASPIRATION CATHETER Carefully read all instructions prior to use, observe all warnings and precautions noted throughout these instructions. Failure to do so may result in complications. STERILE.
More informationMy Indications are based on anatomy
Update in Carotid Artery Stenting &Stroke Management How to choose the best therapy? My Indications are based on anatomy Max Amor M.D max-amor@wanadoo.fr C.Breton,Z.Chati,G.Ethevenot,J.Lemoine,J.P.Simon
More informationDEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service
M AY. 6. 2011 10:37 A M F D A - C D R H - O D E - P M O N O. 4147 P. 1 DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control
More informationAccess More Patients. Customize Each Seal.
Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate
More informationIntroduction 3. What is Peripheral Vascular Disease? 5. What Are Some of the Symptoms of Peripheral Vascular Disease? 6
Patient Information Table of Contents Introduction 3 What is Peripheral Vascular Disease? 5 What Are Some of the Symptoms of Peripheral Vascular Disease? 6 What Causes Peripheral Vascular Disease? 7 How
More informationInstructions for Use Cordis PRECISE PRO Rx Nitinol Stent System
100000017144.3 100000017144.3 Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System Figure 1.065" (1.65 mm) OR.078" (1.98 mm) 16 4 13 10 11 15 8 3 14.062" (1.57 mm) OR.065" (1.65 mm).038" (0.97
More informationPressureWire Aeris with Agile Tip Technology. Wireless FFR Functionality and Handles like a Workhorse PCI Guidewire 1
Home» Products» All International Products» PressureWire Aeris with Agile Tip Technology PressureWire Aeris with Agile Tip Technology This device is commercially available for use in select international
More informationMaximise Clinical Safety*. Cordis ExoSeal. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD
Cordis ExoSeal Vascular Closure Device Cardiology and Endovascular CORDIS EXOSEAL VCD Maximise Clinical Safety*. The novel approach to secure and easy closure. * Clinical data from the ECLIPSE Trial indicates
More informationNew concepts for filter protection during CAS: double filtration. Alberto Cremonesi MD, FESC
New concepts for filter protection during CAS: double filtration Alberto Cremonesi MD, FESC First Experience with the PALADIN Carotid Post-Dilation Balloon with Integrated Embolic Protection Alberto Cremonesi
More informationChronic Total Occlusion (CTO) Technologies
to receive our latest news and key activities. Chronic Total Occlusion (CTO) Technologies Re-open vital channels LinkedIn page Follow us on CORDIS EMEA OUTBACK LTD Re-Entry Catheter True Lumen Re-Entry
More informationZenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up
Zenith Renu AAA Converter Graft Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Device description: Device indications The Zenith Renu AAA Converter Graft with Z-Trak Introduction
More informationMaximize Control. Minimize Migration.
Maximize Control. Minimize Migration. New SHORT WIRE Delivery System SHORT W IRE BILIARY ENDOPROSTHESIS Improved treatment of biliary strictures The self-expanding, fully covered metal stent is intended
More informationTalent Abdominal Stent Graft
Talent Abdominal with THE Xcelerant Hydro Delivery System Expanding the Indications for EVAR Treat More Patients Short Necks The Talent Abdominal is the only FDA-approved device for proximal aortic neck
More informationChronic Total Occlusion (CTO) Technologies. Re-open vital channels
Chronic Total Occlusion (CTO) Technologies Re-open vital channels OUTBACK LTD Re-Entry Catheter True Lumen Re-Entry Technology Get back into the true lumen with ease and precision There are a number of
More informationLOWERING THE PROFILE RAISING THE BAR
LOWERING THE PROFILE RAISING THE BAR INNOVATIVE LOW PROFILE. ADVANCED CLINICAL PERFORMANCE. The AFX TM Endovascular AAA System integrates anatomical fixation with an advanced delivery system and graft
More informationABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM
ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM Pure performance and quality: Stent graft systems by JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development
More informationMicromesh technology in carotid artery treatment what is next? Max Amor MD Clinique Louis Pasteur, Essey-Les-Nancy France
Micromesh technology in carotid artery treatment what is next? Max Amor MD Clinique Louis Pasteur, Essey-Les-Nancy France www.incathlab.com Disclosure Speaker name: Max Amor, MD.... I have the following
More informationRenal Artery Stenting With Embolic Protection
Renal Artery Stenting With Embolic Protection Embolic protection during renal stenting may be beneficial, but new device designs are necessary. BY RAJESH M. DAVE, MD Renal artery stenosis (RAS) is the
More informationVascular V12. Covered Stent. The New Standard of Care
Vascular V12 Covered Stent The New Standard of Care Innovation Novel Thermo-Conformable Covered Stent 316L stainless steel stent completely encapsulated in a proprietary one piece eptfe film cast covering
More informationPrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!!
PrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!! Prof Piotr Pieniazek MD PhD Jagiellonian University Institute of Cardiology, John Paul II Hospital Krakow, Poland
More informationCarotid Revascularization and Medical Management for Asymptomatic Carotid Stenosis
Carotid Revascularization and Medical Management for Asymptomatic Carotid Stenosis William A. Gray MD System Chief of Cardiovascular Services, President, Wynnewood, PA USA Two parallel multi-center randomized,
More informationProven Performance Through Innovative Design *
Proven Performance Through Innovative Design * Deliver Our Next Generation AV Covered Stent Results The COVERA Vascular Covered Stent builds upon proven technologies from the category leader in AV Access.
More informationCarotid Artery Stenting
Carotid Artery Stenting JESSICA MITCHELL, ACNP CENTRAL ILLINOIS RADIOLOGICAL ASSOCIATES External Carotid Artery (ECA) can easily be identified from Internal Carotid Artery (ICA) by noticing the branches.
More informationSMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS
SMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS A NEW STANDARD FOR SMOOTH VASCULAR ACCESS NEEDLE PENETRATION FORCE Needle penetration was measured by the amount of force it took for the needle to
More informationFROM THE EVERYDAY TO THE EXTRAORDINARY
FROM THE EVERYDAY TO THE EXTRAORDINARY Created with the collaboration of more than 250 physicians around the world, ENDURANT empowers you to create stronger outcomes for more patients, including those
More informationWhen Outcomes Matter, Design Matters
to receive our latest news and key activities. Cordis S.M.A.R.T. Self-Expanding Nitinol Lower Extremity Solutions When Outcomes Matter, Design Matters For superficial femoral artery (SFA) and iliac lesions.
More informationStraub Endovascular System &
Straub Endovascular System & S t r a u b E n d o v a s c u l a r To o l s Straub Endovascular System Effective debulking in occluded arteries and veins Effective debulking in many indications Rotarex
More informationAdvanced Innovation for Exceptional Performance
Advanced Innovation for Exceptional Performance longest BALLOON LENGTHS ON THE MARKET Bard Peripheral Vascular Ultraverse 014 300 mm Boston Scientific Coyote 220 mm Cordis SLEEK RX 220 mm Aviator Plus
More informationKoen Keirse, MD RZ Tienen, Belgium
Clinical Benefits of the Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection from the ENTRAP Study Koen Keirse, MD RZ Tienen, Belgium Disclosure Speaker name: Koen Keirse...
More informationAppropriate Device Selection for Endovascular Procedures
Appropriate Device Selection for Endovascular Procedures Thomas M. Shimshak, MD Florida Hospital Heartland Medical Center Sebring, Florida Disclosures Speaker s Bureau: Abbott Vascular Boston Scientific
More informationQuick Reference Guide
Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology
More informationthoracic stent graft system Smallest delivery profile as from 20 F
thoracic stent graft system Smallest delivery profile as from 20 F Third-generation thoracic stent graft system effective, precise and safe JOTEC develops stent graft systems in close collaboration with
More informationPhoenix Atherectomy System Product Overview /LB
Phoenix Atherectomy System Product Overview Phoenix Atherectomy System- The next generation of atherectomy The first hybrid atherectomy system available Combines the benefits of existing atherectomy systems
More informationRuby Coil. Large Volume Detachable Coils
Ruby Coil Ruby Case Examples 38 mm Hepatic Artery Aneurysm Pulmonary AVM 2 Coils Dr. James Benenati Miami Cardiac and Vascular Institute, FL Y90 Embolization Type 2 Endoleak Dr. J Moskovitz Florida Hospital,
More informationCordis ExoSeal. Maximise Clinical Safety*. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD
Cordis ExoSeal Vascular Closure Device CORDIS EXOSEAL VCD Maximise Clinical Safety*. The novel approach to secure and easy closure. * Clinical data from the ECLIPSE Trial indicates safety in terms of vascular
More informationRandomised Trials of Carotid Interventions Will the Changing Technology of Membrane Mesh Stents Shape The Future?
Randomised Trials of Carotid Interventions Will the Changing Technology of Membrane Mesh Stents Shape The Future? Dr Sumaira Macdonald MBChB (Comm.), FRCP, FRCR, PhD, EBIR Vascular Interventional Radiologist
More informationNC EMERGE TM PTCA Dilatation Catheter
LEARN MORE Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. Information for use only in countries with applicable health
More informationBalloon-expandable closed-cell stents were introduced
Designing the Ideal Stent Stent cell geometry and its clinical significance in carotid stenting. BY MARK H. WHOLEY, MD, AND ENDER A. FINOL, PHD Balloon-expandable closed-cell stents were introduced for
More informationCurrent Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center
Current Status of Abdominal Aortic Stent Grafts John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center Autumn Greetings Disclosure Statement of Financial Interest Within
More informationAlgorithm and Tools for the Uncrossable CTO
Algorithm and Tools for the Uncrossable CTO David E. Kandzari, MD, FACC, FSCAI Chief Scientific Officer Director, Interventional Cardiology Piedmont Heart Institute Atlanta, Georgia david.kandzari@piedmont.org
More informationBTK Case Studies Joseph Cardenas, MD AZ Heart & Vascular, Yuma, AZ
BTK Case Studies Joseph Cardenas, MD AZ Heart & Vascular, Yuma, AZ 1 Case 1 78 yr. old female Rutherford Class II/III lesion 1 block claudicant 2 Pre Treatment Post Treatment Anterior Tibial Artery Occlusion
More informationCP STENT. Large Diameter, Balloon Expandable Stent
CP STENT Large, Expandable CP STENT OPTIONS 12mm to Expansion 26mm to Expansion CP Matrix (number of zigs) 1.6 2.2 2.8 3.4 3.9 4.5 5 5.5 6 12 14 15 16 18 20 22 24 26 28 30 CP Details: CP is composed of
More informationWhen and how to use distal protection devices for lower extremity revascularization. Peter A. Schneider, MD Kaiser Foundation Hospital, Honolulu
When and how to use distal protection devices for lower extremity revascularization Peter A. Schneider, MD Kaiser Foundation Hospital, Honolulu Disclosure Peter A. Schneider Potential conflicts of interest
More informationVascular Resistance in the Carotid Artery: An In Vitro Investigation of Embolic Protection Filters
Laboratory Investigations Vascular Resistance in the Carotid Artery: An In Vitro Investigation of Embolic Protection Filters Gail M. Siewiorek, BS, Mark H. Wholey, MD, and Ender A. Finol, PhD PURPOSE:
More informationOptimized for Performance and Ease of Use. Designed with Titanium Oxide Surface. References
References MicroVention data on file low Re-direction Endoluminal Device in treatment of cerebral aneurysms: initial experience with short-term follow-up results, Author: Naci Kocer et al. The RED and
More informationEvaluation of a new micromesh carotid stent with Optical Coherence Tomography.
Evaluation of a new micromesh carotid stent with Optical Coherence Tomography. Technical case report. J. Lemoine,S. Myla,Z. Chati,R.Aslam, M.Amor Clinic Louis Pasteur,Essey les Nancy.France Disclosure
More informationXIENCE Sierra INTRODUCING
INTRODUCING Sierra With the safety you ve always relied on and the deliverability you ve always wanted, choosing the right stent is now an easier decision. START 2017 Abbott. All rights reserved. AP2944678-OUS
More informationSCAFFOLD Study Gore PTFE mesh-covered stent preclinical and clinical data so far. Peter A. Schneider, MD Kaiser Foundation Hospital Honolulu, Hawaii
SCAFFOLD Study Gore PTFE mesh-covered stent preclinical and clinical data so far Peter A. Schneider, MD Kaiser Foundation Hospital Honolulu, Hawaii Disclosure Peter A. Schneider... I have the following
More informationCarotid Artery Stenting
Carotid Artery Stenting Natural history of the carotid stenosis Asymptomatic 80% carotid stenosis - 6% risk of stroke / year Symptomatic carotid stenosis have 10% risk of CVA at one year and 40% at 5 years
More information-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE
Stent Graft SOLUTIONS FOR VASCULAR DISEASE 1 PURE PERFORMANCE AND QUALITY: STENT GRAFT SYSTEMS BY JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development
More informationCombine the best of both worlds
S c i e n c e B a s e d E v o l u t i o n s l e a d t o R e v o l u t i o n a r y S o l u t i o n s PIONEER CoCr STENT ON DEB Combine the best of both worlds A next step in cardiovascular treatment should
More informationNON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER
Page 1 of 5 NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER STERILE. SINGLE USE ONLY. Sterilized with ethylene oxide gas. Non pyrogenic. Do not resterilize. Do not use opened or damaged packages.
More informationVersatility and Proven Safety
Versatility and Proven Safety Indicated for: Temporary or Permanent placement Standard or Over-The-Wire Delivery Jugular, Femoral, Antecubital, and Popliteal Access > Proven Safety Initial Clinical Trial
More informationNAVIGATE DISTAL AND TORTUOUS ANATOMY
PROGREAT ALPHA PUSHINGBOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging cases. We are relentlessly
More informationTurboHawk. Plaque Excision System
TurboHawk Plaque Excision System Twelve-month Patency in Diabetics DIABETICS VS. NON-DIABETICS 12-month Primary Patency (%) Diabetic patients show a more positive response to directional atherectomy than
More informationMechanical Thrombectomy of Large Vessel Occlusions Using Stent Retriever Devices
Mechanical Thrombectomy of Large Vessel Occlusions Using Stent Retriever Devices Joey English MD, PhD Medical Director, Neurointerventional Services California Pacific Medical Center Hospitals, San Francisco,
More informationROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards
Peripheral ROTABLATORTM Rotational Atherectomy System Quick Reference Cards Technical Assistance: 1.800.949.6708 Customer Service: 1.888.272.1001 Complaints: 1.800.811.3211 Setup Video: www.bostonscientific.com/rotablatorsetup
More informationA New EVAR Device for Infrarenal AAAs
A New EVAR Device for Infrarenal AAAs Peter Nelson, MD, MS Assistant Professor of Surgery MM0203 Rev. 01 Current U.S. EVAR Devices Anatomical Fixation Proximal Fixation Powerlink - Endologix Excluder WL
More informationPTA Balloon Dilatation Catheter
PTA Balloon Dilatation Catheter March 2016 1/6(3214-0) Catalogue number Serial number Lot number Use by Do not reuse Do not resterilize Do not use if package is damaged Consult instructions for use Keep
More informationPTA Balloon Dilatation Catheter
PTA Balloon Dilatation Catheter 1/6(3211-0) February 2016 TIS-488-06272017 Catalogue number Serial number Lot number Use by Do not reuse Do not resterilize Do not use if package is damaged Consult instructions
More informationGuide Wires design and selection Abbott Vascular. All rights reserved.
Guide Wires design and selection the cardiac catheter was...the key in the lock Cournand AF, Nobel lecture December 11, 1956; nowadays, the coronary guidewire is the master key to all locks Colombo et
More informationENG TREO ABDOMINAL STENT-GRAFT SYSTEM TABLE OF CONTENTS
TREO ABDOMINAL STENT-GRAFT SYSTEM TABLE OF CONTENTS 1. DEVICE DESCRIPTION 28 1.1. Stent-Graft 28 1.1.1. Main Bifurcated Stent-Graft 28 1.1.2. Leg Extensions 28 1.2. Delivery System for the Bifurcated Main
More informationAnatomical challenges in EVAR
Anatomical challenges in EVAR M.H. EL DESSOKI, MD,FRCS PROFESSOR OF VASCULAR SURGERY CAIRO UNIVERSITY Disclosure Speaker name:... I have the following potential conflicts of interest to report: Consulting
More informationLow profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster
Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster Disclosure Speaker name:...michel Bosiers... I have the following potential conflicts of interest to report: Consulting Employment
More informationTriVascular Ovation Prime Abdominal Stent Graft System
TriVascular Ovation Prime Abdominal Stent Graft System Science of the Seal O-Ring Sealing Technology O-Ring Sealing in Proven Engineering Solutions O-rings are designed to seal by blocking the flow of
More informationZenith Alpha T HORACIC ENDOVASCULAR GRAFT
Deployment Sequence Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21183-EN-F Preparation and flush Proximal and distal components Remove the yellow hubbed inner stylet from the dilator
More informationWelcome to the 8 th European Bifurcation Club October Barcelona
Welcome to the 8 th European Bifurcation Club 12-13 October 2012 - Barcelona Safety and clinical efficacy of Sideguard stent for treatment of bifurcation lesions Interim results from European multicentre
More information5F Devices with 0.035
Ambulatory mamagement for PAD endovascular treatment 5F Devices with 0.035 Flavio Airoldi, MD Multmedica IRCCS Milan - ITALY flavio.airoldi@multimedica.it Is there a need for low profile delivery systems?
More informationJETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW
JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW DISCOVER THE VALUE OF VERSATILITY Versatility means not having to guess the morphology! Peripheral arterial lesions can present with
More informationMy personal experience with INCRAFT in standard and challenging cases
My personal experience with INCRAFT in standard and challenging cases G Pratesi, MD Vascular Surgery University of Rome Tor Vergata giovanni.pratesi@uniroma2.it Disclosure Speaker name: Giovanni Pratesi,
More informationSCAI Fall Fellows Course Subclavian/Innominate Case Presentation
SCAI Fall Fellows Course 2012 Subclavian/Innominate Case Presentation Daniel J. McCormick DO, FACC, FSCAI Director, Cardiovascular Interventional Therapy Pennsylvania Hospital University of Pennsylvania
More informationThe evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System
The evolution of AORFIX AORFIX AAA Stent Graft now with the new AORFLEX Delivery System The confident choice for the right angles AORFIX the only AAA stent graft approved for all angulations from 0 90,
More informationCarotid artery percutaneous treatment: back to the future Alberto Cremonesi MD, FESC
Carotid artery percutaneous treatment: back to the future Alberto Cremonesi MD, FESC GVM Care & Research - Cardiovascular Department (Cotignola Italy) Hypothesis: Does CAS present similar outcomes than
More informationWallFlex Biliary Metal Stents
WallFlex Biliary Metal Stents Please Note: These steps are intended to be for general guidance only. For complete instructions for use, indications, contraindications and warnings, please refer to the
More informationTechniques for Carotid Interventon
Techniques for Carotid Interventon Jay S. Yadav MD Cleveland, Ohio Disclosures Inventor of Angioguard; fixed and recurring payments from JNJ Advisor: JNJ, Guidant Understand the Patient What is the Cause
More informationGuidewire Selection. Making the Most Out of My Guidewire: LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016
Making the Most Out of My Guidewire: Guidewire Selection LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016 Brian DeRubertis, MD, FACS Associate Professor of Surgery Division
More informationChallenging anatomies demand versatility.
Challenging anatomies demand versatility. The Distinct Advantages of Separating Seal and Fixation ANATOMICAL FIXATION Unlike proximal fixation designs, the AFX bifurcated unibody endograft allows for natural
More informationWael Tawfick Sherif Sultan UCHG, NUIG, RCSI
Carotid Artery Stenting Cervical Approach Wael Tawfick Sherif Sultan UCHG, NUIG, RCSI 1. Western Vascular Institute, University College Hospital, Galway, Ireland (UCHG) 2. School of Medicine, National
More informationExcimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING
Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING 1 2013 Spectranetics. All Rights Reserved. Approved for External
More informationAXS Catalyst Distal Access Catheter
AXS Catalyst Distal Access Catheter Directions for Use 2 AXS Catalyst Distal Access Catheter ONLY Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. warning Contents
More informationUreteroscopy solutions for your most challenging cases.
Ureteroscopy solutions for your most challenging cases. IT TAKES INSIGHT TO SEE THAT NO TWO STONE PATIENTS ARE ALIKE. THAT S THE DIFFERENCE BETWEEN MAKING DEVICES AND MAKING PROGRESS. There is nothing
More information