CT angiography of pulmonary arteries to detect pulmonary embolism with low kv settings

Size: px
Start display at page:

Download "CT angiography of pulmonary arteries to detect pulmonary embolism with low kv settings"

Transcription

1 CT angiography of pulmonary arteries to detect pulmonary embolism with low kv settings Poster No.: C-3289 Congress: ECR 2010 Type: Scientific Exhibit Topic: Chest - Your latest results Authors: M. K. Gill, A. Vijayananthan, G. K. Kumar, K. H. Ng, K. Jayarani; Kuala Lumpur/MY Keywords: kvp: x-ray tube voltage, mas: x-ray beam intensity, CTPA: CT angiography of the pulmonary arteries Keywords: Lung, Respiratory system, Thorax DOI: /ecr2010/C-3289 Any information contained in this pdf file is automatically generated from digital material submitted to EPOS by third parties in the form of scientific presentations. References to any names, marks, products, or services of third parties or hypertext links to thirdparty sites or information are provided solely as a convenience to you and do not in any way constitute or imply ECR's endorsement, sponsorship or recommendation of the third party, information, product or service. ECR is not responsible for the content of these pages and does not make any representations regarding the content or accuracy of material in this file. As per copyright regulations, any unauthorised use of the material or parts thereof as well as commercial reproduction or multiple distribution by any traditional or electronically based reproduction/publication method ist strictly prohibited. You agree to defend, indemnify, and hold ECR harmless from and against any and all claims, damages, costs, and expenses, including attorneys' fees, arising from or related to your use of these pages. Please note: Links to movies, ppt slideshows and any other multimedia files are not available in the pdf version of presentations. Page 1 of 32

2 Purpose General Objective: To assess the feasibility of using a low kvp technique in the evaluation of pulmonary embolism. In developing countries like ours, where 16 slice multidetector scanners are still widely used, this study may be beneficial in improving the efficacy of the available scanners as well as reducing the radiation dose. Specific Objective: 1. To assess the image quality of the low dose (100kVp) protocol as compared to the standard dose(120kvp) protocol. 2. To determine the ideal mas for the low dose protocol and also to calculate the amount of radiation dose reduction using a preliminary phantom study. Page 2 of 32

3 Methods and Materials Patient selection and period of study: A prospective study was carried in all patients at our center suspected of having pulmonary embolism based on the presence of one or more of the following symptoms: shortness of breath, chest pain, cough and hemoptysis. The patients were divided into two groups; the first group of 33 patients (group A) was scanned with a low dose 100kVp protocol; while the second group of 33 patients (group B) were scanned with the standard dose 120kVp protocol. This study was divided into two phases: 1) a preliminary phantom study to determine the ideal mas for the low dose protocol and also to calculate the amount of radiation dose reduction 2) the main study to evaluate image quality of the low dose protocol with the preset protocol as a standard value. Patient demographics: In total, 66 consecutive patients were recruited and their ages ranged from 19 to 87 years (median age years). We measured the antero-posterior (AP) and transverse diameters of the chest at the level of the main pulmonary artery. The patient demographics which included: sex, age, and body weight were obtained from patient records. Eligibility Criteria: 1. Inclusion Criteria Page 3 of 32

4 All patients suspected with pulmonary embolism from A&E and wards. The weight of the patient should be within 50 to 70kg. 2. Exclusion criteria: Patients who were below 18 years of age, those unable to hold their breath for at least 20seconds, pregnant women and those with severe spinal deformities or had metal thoracic implants. Study Design: 1. Preliminary study (phantom) A phantom study was done to obtain a suitable protocol for optimisation of the low dose scanning technique. Using the 120kVp 90mAs as a standard, different mas ranging from 70 to 135 were compared with 100kVp on a phantom to obtain the most suitable mas for the 100kv protocol without significantly affecting the image quality. 2. Scanning Protocol on patients 16 slice spiral MDCT caudal-cranial direction 5.0mm slice thickness Pitch 1.5 Total rotation time: 18.0 seconds Collimation: 16 x 0.75mm Start delay: Smart Prep HU=100 at right ventricle Contrast media: mls of IV Iopromide 370 mg I/ml at 3-4mls per second Exposure parameters varied between groups A and B. Patients in group A were scanned with a low-dose, low kilovoltage protocol at 100 kvp and 115 mas(predetermined by a phantom study), while for the standard protocol in group B, we used 120 kvp and 90 mas. (Figure 1) Image Evaluation: Page 4 of 32

5 Quantitative and subjective analyses were made as follows (Figure 2): 1. Quantification Analysis (a) Vascular attenuation. To evaluate attenuation in the central pulmonary arteries, we measured the mean CT number (in Hounsfield units) in the main pulmonary artery by using a region of interest 2 2 of at least 1.0cm (± 0.5cm ). We also evaluated the maximum attenuation (CT number) of peripheral pulmonary arteries close to the beginning and the end of each scan in a segmental or sub-segmental artery at an apical and a basal section position.the maximum CT number was used as a proxy for vascular attenuation because the caliber of the peripheral vessels was too small to reliably set an intraluminal region of interest to determine the mean CT number. (b) Image noise. Objective quantification of the image noise was analysed by measuring the standard 2 deviation(sd) in three homogeneous regions of interest measuring about 1.0cm (± 2 0.5cm ) in the main pulmonary artery that was free of motion or contrast material-induced artifacts. The SD served as quantitative marker of image noise. Signal intensity (SI) (ie, CT number) measurements were determined in three 2 2 homogeneous regions of interest measuring about 1.0cm (± 0.5cm ) in the main pulmonary artery. On the basis of these numbers the average main pulmonary artery signal intensity (SIMPV) was calculated. The measurement of background noise was based on the standard deviation (in Hounsfield units) of three 1cm² regions of interest in front of the patient (central, left and right). These values were averaged to obtain the final background noise (BN). In addition, attenuation of the paraspinal muscles were measured on both sides and averaged (muscle SI). Based on these measurements the signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated using the following equations: SNR = SIMPV/BN Page 5 of 32

6 CNR = (SIMPV # muscle SI)/BN where SIMPV is mean SI of main pulmonary artery, muscle SI is the mean signal intensity at the paraspinal muscle and BN is background noise. (c) Analysis of segmental arteries Analysis of segmental arteries was done on transverse images only. We used a CT angiography window setting (width, 450 HU; level, 100 HU) and a lung window setting (width, 1500 HU; level, -500 HU) for this analysis. The arteries were named according to the nomenclature of Remy-Jardin et. al. as described by Boyden, and according to the nomenclature of Jackson and Huber. This nomenclature assigns 10 segmental arteries on the right and nine segmental arteries on the left. Therefore, a total of 19 segmental arteries could be expected per patient if no anatomic variant was present. For each patient, we then calculated the percentage of analyzable segmental arteries. Subjective evaluation Two senior radiologists with more than 10 years of experience performed consensus interpretation of the CT images. Images were presented to the observers who were blinded to the patient and scan data in random order. After reviewing several previous studies, the reviewers predetermined the pulmonary artery settings based on consensus and used a window width between and widow level between in order to compensate for increased attenuation within the pulmonary arteries at low kilovoltage setting The mediastinum, liver and lungs were assessed in the mediastinal (WW450 WL100) and lung (WW1500; WL-500) window settings. The following parameters were assessed: (a) Image quality The images were subjectively analyzed for making a diagnosis other than PE and scored by using a five-point scale ranging from 1 to 5 as follows: (Figure 3) a score of 1 : very bad image quality that no diagnosis can be made Page 6 of 32

7 a score of 2: low image quality that reduced the confidence in making the diagnosis a score of 3: moderate image quality sufficient to make a diagnosis a score of 4: good image quality a score of 5: excellent image quality that enabled excellent differentiation of even small structures Subsequently, image quality for selected anatomic areas such as the mediastinum, the lungs, the main pulmonary artery, and the liver parenchyma were assessed separately. (b) Pulmonary artery contrast enhancement The degree of contrast enhancement was also graded by using a five-point scale (Figure 3), and the subjective contrast enhancement score was determined by evaluating the main pulmonary arteries. After reviewing several previous studies, the reviewers predetermined the pulmonary artery settings based on consensus and used a window width between and window level between in order to compensate for increased attenuation within the pulmonary arteries at low kilovoltage settings (c) Image noise and Motion artifacts The degree of presence and effect of image noise and motion artifacts were similarly graded using a five-point scale (Figure 3). The different anatomical areas were combined to rate the image noise and presence of motion artifacts only once per examination. Radiation Dose Evaluation: The Computed Tomography weighted Dose Index (CTDIvol) is preset by the CT scanner based on measurement of the selected pitch value which was 5.74 for Group A and 7.01 for Group B. The system then determines the scan length from the topogram and combines it with the CTDIvol to calculate the dose length product (DLP) in each patient respectively. The DLP is a measure of the radiation dose delivered to that patient during the scan. Estimation of the effective dose was performed based on the DLP which was converted using a standardized conversion factor of 0.017mSv/mGy for chest CT. Page 7 of 32

8 Estimated Effective dose = Dose Length Product (DLP) / In addition, the Effective radiation doses values for males and females were calculated according to International Commission of Radiation Protection (IRCP). This value was evaluated using a phantom during the first phase of our study. Page 8 of 32

9 Images for this section: Fig. 0: Flow chart on study design Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 9 of 32

10 Fig. 0: Flow chart on data analysis Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 10 of 32

11 Fig. 0: Five-Point Scales for Subjective Rating of Image Quality Characteristics Schueller-Weidekamm C et al.(2006) CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.radiology;241(3): Page 11 of 32

12 Results Study Groups. There were 66 patients used in this study; 25 (36%) were male and 41 (59%) were females with age group ranging from 19 to 87 years with a mean of Comparison of the two patient groups did not reveal any significant differences in patients age, sex, amount of extrathoracic soft tissue, AP and transverse diameters of the chest as well as in the incidence of PE. CT evaluation of the pulmonary arteries demonstrated PE in 11 patients (15%). (Figure 1). The mean age in group A was 50.8 years ± 18.9 [range, years], while mean age in group B was 54.8 years ± 17.4 [range, years]; (P =.372, t test) or sex (there were 13 male patients in group A vs 12 male patients in group B, while there were 20 females in group A vs 21 female patients in group B; P =.250, t test). The mean body weight in group A was 58.2Kg ± 7.1, while mean body weight in group B was 60.4Kg ± 5.6; indicating no significant difference in the body weight between the two groups (P =.167, t test). There was also no significant difference noted between the antero-posterior and transverse diameters of the chest as well as the skin to rib thickness between the two protocols. (Figure 1) Phantom Analysis We matched 70, 80, 90, 100, 115, 120, 125, 130 and 135mAs with the low dose protocol, and concluded that an effective mas of 115 was ideal for the 100kVp protocol as it did not significantly affect the image noise. It also provided a 17.5% reduction in radiation dose in the 100kVp protocol using the 120kVp protocol as a standard (Figure 2) Patient Analysis 1. Quantification Analysis (a) Quantification of Vascular Enhancement Page 12 of 32

13 Both central pulmonary arteries (measured in the main pulmonary artery) and peripheral arteries showed significantly higher attenuation with the 100-kVp protocol than with the standard 120-kVp protocol as shown in Figure 3 and Figure 4. All differences were significant at a level of P <.001. The average attenuation in the main pulmonary artery was 486 HU ± (95% confidence interval [CI]: 70, 172 HU) in group A and 347.3HU ± 93.1 (95% CI: 60, 172 HU) in group B; P <.001, t test. In the peripheral pulmonary arteries at the level of the aortic arch, the maximum attenuation was 503.4HU ± (95% CI: 45, 162 HU) for group A and 399.5HU ± 82.2 (95% CI: 45, 162 HU) for group B; P <.001, t test. In peripheral pulmonary arteries at the lung base, the maximum attenuation was 481.6HU ± 98.9 (95% CI: 59, 148 HU) for group A and 377.6HU ± 79.8 (95% CI: 59, 148 HU) for group B; P <.001, t test. (b) Image Noise Image noise measured at the level of the main pulmonary artery was 25.7 HU ± 6.3 for group A and 14.2 HU ± 3.0 for group B. The difference was statistically significant (P = <.001). (Figure 5) Background noise increased from 24.2HU ± 10.2(Group B) to 27.0HU ± 9.8 (Group A), which was not a significant difference (P =.28). There was no significant difference between the patient groups A (100kVp) and B(120kVp) respectively for SNR (18.6HU ± 8.3 vs 16.5HU ± 7.1; P =.26) however there was significant increase in the CNR between the two groups (440.5HU ± vs 350.2HU ± 101.5; P = <.001) which was an outcome that was generally expected with the low kvp protocol. (Figure 5) (c) Analysis of Segmental Arteries A total of 792 segmental arteries (396 each in group A and group B:) were analyzed. The percentage of segmental arteries that were considered to have sufficient quality for assessment of PE did not significantly differ between group A (mean, 91% ± 15) and group B (mean, 91% ± 7) (P =.85, Mann-Whitney U test). Figure 6 demonstrates filling defects within the segmental branches in both the protocols. Page 13 of 32

14 2. Subjective Grading of Image Quality There was no significant difference of inter-observer variability between the two protocols (Figure 7). However a consensual agreement was made and all results were subsequently obtained as follows: (a) Image quality Subjective scores for image quality were lower for the 100-kVp images than for the 120kVp images, while the vascular enhancement was higher in the 100-kVp protocol but the difference between the average scores were not significant (Figure 8). Differences in subjective scoring did not reach significance for any of the five anatomic areas (main pulmonary artery: P =.43; lungs: P =.02; mediastinum: P =.13; liver 2 parenchyma: P =.18; t test). (Figure 9) None of the scans was considered to have such low image quality that it would interfere with diagnosis (grades 1 or 2) for the anatomic regions evaluated(figure 8). (b) Pulmonary artery contrast enhancement The 100-kVp scans were rated as having significantly superior contrast enhancement (mean score, 4.6 vs 3.9; P = <.001). (Figure 9) (c) Image noise and motion artifacts There was no significant difference for the subjective grading of image noise (mean score, 4.6 vs 4.6; P =.659) or of motion artifacts (mean score, 4.8 vs 4.8; P =.804) for the 100kVp and 120-kVp images, respectively. (Figure 9) Radiation Exposure Page 14 of 32

15 Concerning radiation exposure, the preset CTDIvol (mgy) values given by the scanner were 5.74 mgy for Group A and 7.01 mgy for Group B. There was a significant difference noted in the DLP and estimated effective dose between Group A and Group B; Dose length product (186.3 mgy x cm ± 21.8 vs mgy x cm ± 60.5, respectively; p<.001), and estimated effective dose (3.16 msv ± 0.38 vs 6.79 msv ± 1.40, respectively (P <.001). The latter corresponds to an average reduction of estimated effective dose of approximately 53% (Figure 10). Page 15 of 32

16 Images for this section: Fig. 0: Descriptive statistics of demographic and morphologic data of 66 consecutive patients examined at 100kVp(Group A) and 120kVp(Group B) CT Pulmonary Arteriograms Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 16 of 32

17 Fig. 0: Phantom study where the 120kVp protocol was refered to as a standard to get an appropriate mas for the 100kVp(low dose) protocol without significantly affecting the image quality. We concluded that 115 mas was the ideal for the 100kVp(low dose) protocol as it did not significantly affect the image quality and at the same time reduced the radiation dose by 17.5%. Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 17 of 32

18 Fig. 0: Contrast enhanced CT pulmonary arteriogram in mediastinal window setting(ww 400 ; WL 100) demonstrating the comparison of vascular enhancement at the level of main pulmonary artery (A) showing enhancement of HU that is close to the average in 120kVp group and (B) showing a much higher enhancement of HU that was noted in the 100kVp protocol. Circles indicated the ROI of 1.0cm² (±0.5) that was used to measure the average CT number at the main pulmonary artery. Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 18 of 32

19 Fig. 0: Box plot demonstrating the average attenuation in the main pulmonary artery is significantly higher in the 100kVp low dose protocol as compared to the 120kVp standard protocol Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 19 of 32

20 Fig. 0: There was a significant increase in image noise (standard deviation at the level of the main pulmonary artery) in the 100kVp protocol as was expected with a lower kvp. However, there was no significant difference in the SNR while there was a significant difference in the CNR between the two protocols. This result was expected as different behavioural pattern of iodine within the vessels and surrounding soft tissue should lead to a higher contrast between these two structures thereby increasing the CNR. Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 20 of 32

21 Fig. 0: Contrast enhanced CT pulmonary studies in Axial sections at the level of the main pulmonary artery in two patients with pulmonary embolism demonstrating the comparison of image quality at the central and peripheral pulmonary arteries in (A) the low dose 100kVp protocol and (B) in the standard dose 120 kvp protocol. Note the emboli in the lower lobe segmental arteries (arrows) Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 21 of 32

22 Fig. 0: Demonstration of the inter-observer variability for subjective image quality Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 22 of 32

23 Fig. 0: Demonstrating the difference in subjective image quality by consensus between the two protocols. Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 23 of 32

24 Fig. 0: Statistical analysis of subjective image evaluation between the two protocols Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 24 of 32

25 Fig. 0: The preset CTDIvol(mGy) values were given by the scanner. There was a significant difference noted in the DLP and estimated effective dose between Group A and Group B, indicating a significant dose reduction in the low dose 100kVp protocol. Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 25 of 32

26 Conclusion Use of a 100 kvp setting in the CTPA examination results in a significant reduction in the radiation exposure whilst increasing the iodine attenuation level. This actually increases pulmonary artery enhancement Although the image noise was increased, the subjective and objective image evaluation did not demonstrate a significant decrease in image quality between the 100kVp(low dose) and 120kVp (standard dose) protocols. Figures 1 and 2 demonstrate the image quality and vascular enhancement in the 100kVp and 120kVp protocols in two separate patients respectively who were positive for pulmonary embolism. Future prospects of this study Beneficial in other vascular CT studies as well as in the dual source CT scanners because of increase in the attenuation of the vessels with the low kvp protocol. In developing countries like ours, where 16 slice multidetector scanners are still widely used, this study may be beneficial in improving the efficacy of the available scanners as well as reducing the radiation dose. Page 26 of 32

27 Page 27 of 32

28 Images for this section: Fig. 0: Contrast enhanced CT pulmonary arteriogram in pulmonary artery window (WW 1600 ; WL 700) in a 58 year old male with history of sudden onset shortness of breath demonstrating filling defects at the segmental arteries (arrows) pulmonary arteries in the 100 kvp protocol in (A) axial sections and (B) coronal sections. Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 28 of 32

29 Fig. 0: Contrast enhanced CT pulmonary arteriogram in pulmonary artery window (WW 1600 ; WL 700) in a 42 year old male with history of cough and breathlessness demonstrating filling defects at the segmental arteries (arrows) pulmonary arteries in the 120 kvp protocol in (A) axial sections and (B) coronal sections. Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 29 of 32

30 References 1. Kalra MK, Prasad S, Saini S, et al. Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. AJR Am J Roentgenol 2002; 179: Claudia Schueller-Weidekamm, et al, CT Angiography of Pulmonary Arteries to Detect Pulmonary Embolism: Improvement of Vascular Enhancement with Low Kilovoltage Settings Radiology 2006; 241: Christoph M. Heyer, et al. Image Quality and Radiation Exposure at Pulmonary CT Angiography with 100- or 120-kVp Protocol: Prospective Randomized Study; Radiology: Volume 245: Number 2-November Takahashi M, Maguire WM, Ashtari M, et al. Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique. Invest Radiol 1998; 33: Diederich S, Lenzen H, Windmann R, et al. Pulmonary nodules: Experimental and clinical studies at low-dose CT. Radiology 1999; 213: Szucs-Farkas.Z. et al in Detection of Pulmonary Emboli With CT Angiography at Reduced Radiation Exposure and Contrast Material Volume: Comparison of 80 kvp and 120 kvp Protocols in a Matched Cohort. 7. Wintersperger B, Jacobs T, Herzog P, et al. Aorto-iliac multidetector-row CT angiography with low kv settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 2005;15(2): Prasad SR, Wittram C, Shepard JA, McLoud T, Rhea J. Standard-dose and 50%- reduced-dose chest CT: comparing the effect on image quality. AJR Am J Roentgenol 2002; 179: Wintermark, M., P. Maeder, et al. (2000). "Using 80 kvp versus 120 kvp in perfusion CT measurement of regional cerebral blood flow." AJNR Am J Neuroradiol 21(10): Wintersperger, B., T. Jakobs, et al. (2005). "Aorto-iliac multidetector-row CT angiography with low kv settings: improved vessel enhancement and simultaneous reduction of radiation dose." Eur Radiol 15(2): Boyden EA. Segmental anatomy of the lungs. New York, NY: McGraw-Hill, Jackson CL, Huber JF. Correlated applied anatomy of the bronchial tree and lungs with a system of nomenclature: diseases. Chest 1943;9: Page 30 of 32

31 Personal Information Dr Maninderpal Kaur Gill, MBBS, Associate Professor Dr. Anushya Vijayananthan, MBBS, M Rad, Professor Dr. Gnana Kumar, MBBS, MMed (RAD), FRCR, Dr. Kasthoori Jayarani, MBBS, M Rad, FRCR, Professor Dr. Ng Kwan Hoong, PhD, FIPM, MIPEM, DABMP. Department of Biomedical Imaging, University of Malaya Kuala Lumpur, Malaysia mindy_gill@yahoo.com Page 31 of 32

32 Images for this section: Fig. 0 Department of Bio-Imaging, University Malaya Medical Center - Kuala Lumpur/MY Page 32 of 32

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T. The feasibility of biphasic contrast-media-injection-protocol for chest imaging on 320-slice volume MDCT: Direct comparison of biphasic and bolus contrast-media injection protocols on 320-slice volume

More information

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients 128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients Poster No.: C-0634 Congress: ECR 2010 Type: Scientific Exhibit Topic: Cardiac Authors: Y. H. Choe, J. W. Lee,

More information

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006).

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006). Feasibility, image quality and radiation dose of coronary CT angiography (CCTA) in patients with atrial fibrillation using a new generation 256 multi-detector CT (MDCT) Poster No.: C-2378 Congress: ECR

More information

High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous?

High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous? High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous? Poster No.: C-1753 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit B. Y. Lee, H. R. KIM, J. I. Jung,

More information

64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes

64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes 64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes Poster No.: C-051 Congress: ECR 2009 Type: Scientific Exhibit Topic: Abdominal and Gastrointestinal Authors:

More information

Monophasic versus biphasic contrast application in CT of patients with head and neck tumour

Monophasic versus biphasic contrast application in CT of patients with head and neck tumour Monophasic versus biphasic contrast application in CT of patients with head and neck tumour Poster No.: C-3331 Congress: ECR 2010 Type: Topic: Authors: Keywords: DOI: Scientific Exhibit Head and Neck G.

More information

Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos

Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos Poster No.: C-3032 Congress: ECR 2010 Type: Scientific Exhibit Topic: Radiographers Authors: P.

More information

Application of CARE kv and SAFIRE in Contrast-Enhanced CT Examination on Thorax

Application of CARE kv and SAFIRE in Contrast-Enhanced CT Examination on Thorax Application of CARE kv and SAFIRE in Contrast-Enhanced CT Examination on Thorax Poster No.: C-0013 Congress: ECR 2013 Type: Authors: Scientific Exhibit Z. Dejian 1, X. Zhuodong 2, J. Hui 2, L. Xiao 3 ;

More information

Scientific Exhibit Authors:

Scientific Exhibit Authors: Clinical Audit on Optimization of Radiation Dose from MDCT: Effect on Diagnostic Reference Levels for Brain, Sinus, Cervical Spine, Chest, Abdomen-Pelvis, and Lumbar Spine Examinations and on Nationwide

More information

Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation.

Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation. Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation. Award: Poster No.: E-0004 Certificate of Merit Congress:

More information

Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil

Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil Poster No.: C-0671 Congress: ECR 2016 Type: Educational Exhibit Authors: H. Patel 1, W. Liu 2, J. DeSanto 2, S. Meagher 2, M. Zagardo 2,

More information

B. CT protocols for the spine

B. CT protocols for the spine B. CT protocols for the spine Poster No.: A-003 Congress: ECR 2010 Type: Invited Speaker Topic: Neuro Authors: B. Tins; Oswestry/UK Keywords: CT, spine, diagnostic imaging protocol DOI: 10.1594/ecr2010/A-003

More information

Radiation induced DNA double strand breaks undergoing PET/CT examinations.

Radiation induced DNA double strand breaks undergoing PET/CT examinations. Radiation induced DNA double strand breaks undergoing PET/CT examinations. Poster No.: C-1685 Congress: ECR 2011 Type: Scientific Exhibit Authors: M. S. May, M. Brand, T. Löwe, M. Sommer, C. Engert, U.

More information

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes Poster No.: C-0488 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit E.-J. Kang,

More information

A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT

A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT Poster No.: C-0623 Congress: ECR 2017 Type: Authors: Keywords: DOI:

More information

Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy

Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy Poster No.: C-1785 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific

More information

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Poster No.: C-2511 Congress: ECR 2012 Type: Scientific Exhibit Authors: N. D. Gupta, M. K. Heir, P. Bradding; Leicester/UK Keywords:

More information

A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography.

A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography. A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography. Poster No.: C-1787 Congress: ECR 2012 Type: Educational Exhibit Authors: N. Ahmed 1, G. Avery

More information

Contrast enhancement of the right ventricle during coronary CTA: is it necessary?

Contrast enhancement of the right ventricle during coronary CTA: is it necessary? Contrast enhancement of the right ventricle during coronary CTA: is it necessary? Poster No.: C-1545 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit M. Kok, C. Mihl, B. Kietselaer,

More information

Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine

Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine Poster No.: C-2125 Congress: ECR 2015 Type: Authors: Scientific Exhibit S. patil 1, A. M.

More information

The effect of CT dose reduction on performance of a diagnostic task

The effect of CT dose reduction on performance of a diagnostic task The effect of CT dose reduction on performance of a diagnostic task Poster No.: B-0856 Congress: ECR 2012 Type: Scientific Paper Authors: D. Zhang, M. Khatonabadi, H. Kim, C. Jude, E. Zaragoza, S. McNitt-Gray,

More information

The effect of CT dose reduction on performance of a diagnostic task

The effect of CT dose reduction on performance of a diagnostic task The effect of CT dose reduction on performance of a diagnostic task Poster No.: B-0856 Congress: ECR 2012 Type: Scientific Paper Authors: D. Zhang, M. Khatonabadi, H. Kim, C. Jude, E. Zaragoza, S. McNitt-Gray,

More information

Chest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study

Chest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study Chest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study Poster No.: C-1207 Congress: ECR 2013 Type: Scientific Exhibit Authors: Y. Shimomiya, M. Kondo, M.

More information

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients Poster No.: C-2511 Congress: ECR 2012 Type: Scientific Exhibit Authors: N. D. Gupta, M. K. Heir, P. Bradding; Leicester/UK Keywords:

More information

Utilization patterns and yield of Computed Tomography Pulmonary Angiogram (CTPA) at a tertiary teaching hospital - Liverpool Hospital

Utilization patterns and yield of Computed Tomography Pulmonary Angiogram (CTPA) at a tertiary teaching hospital - Liverpool Hospital Utilization patterns and yield of Computed Tomography Pulmonary Angiogram (CTPA) at a tertiary teaching hospital - Liverpool Hospital Poster No.: R-0017 Congress: Type: Authors: Keywords: DOI: 2014 CSM

More information

3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy

3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy 3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy Poster No.: C-0493 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper A. LONG

More information

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate Poster No.: B-0742 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Paper

More information

CT Fluoroscopy-Guided vs Multislice CT Biopsy ModeGuided Lung Biopies:a preliminary experience

CT Fluoroscopy-Guided vs Multislice CT Biopsy ModeGuided Lung Biopies:a preliminary experience CT Fluoroscopy-Guided vs Multislice CT Biopsy ModeGuided Lung Biopies:a preliminary experience Poster No.: C-0097 Congress: ECR 2016 Type: Scientific Exhibit Authors: A. Casarin, G. Rech, C. Cicero, A.

More information

FDG-18 PET/CT - radiation dose and dose-reduction strategy

FDG-18 PET/CT - radiation dose and dose-reduction strategy FDG-18 PET/CT - radiation dose and dose-reduction strategy Poster No.: C-1856 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit P. Nicholson, S. McSweeney, K. O'Regan; Cork/IE Radiation

More information

Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma

Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma Poster No.: C-0729 Congress: ECR 2013 Type: Scientific Exhibit Authors: A. Marin, I. Pozek,

More information

Acute abdominal venous thromboses- the hyperdense noncontrast CT sign

Acute abdominal venous thromboses- the hyperdense noncontrast CT sign Acute abdominal venous thromboses- the hyperdense noncontrast CT sign Poster No.: C-1095 Congress: ECR 2011 Type: Educational Exhibit Authors: M. Goldstein, K. Jhaveri; Toronto, ON/CA Keywords: Abdomen,

More information

How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained

How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained Poster No.: C-3077 Congress: ECR 2010 Type: Educational Exhibit Topic: Vascular Authors: D. V. Thomas; Northampton/UK

More information

Pulmonary infarction semiology in CT. Revision of 80 cases.

Pulmonary infarction semiology in CT. Revision of 80 cases. Pulmonary infarction semiology in CT. Revision of 80 cases. Poster No.: C-0369 Congress: ECR 2012 Type: Scientific Exhibit Authors: M. González Vázquez, D. Castellon, J. Calatayud, N. Silva 1 2 1 1 1 1

More information

Postmortem Computed Tomography Finding of Lungs in Sudden Infant Death.

Postmortem Computed Tomography Finding of Lungs in Sudden Infant Death. Postmortem Computed Tomography Finding of Lungs in Sudden Infant Death. Poster No.: C-1147 Congress: ECR 2013 Type: Educational Exhibit Authors: Y. Kawasumi, A. Usui, Y. Hosokai, M. Sato, A. Nakajima,

More information

Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study

Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study Poster No.: R-0016 Congress: 2015 ASM Type: Scientific Exhibit Authors: J. Au, A. Webb, G. Buirski, P. Smith, M. Pickering, D.

More information

Uozu city/jp, Minatoku, Tokyo/JP Bones, Extremities, CT, Surgery, Physics, Artifacts, Image verification /ecr2014/C-0462

Uozu city/jp, Minatoku, Tokyo/JP Bones, Extremities, CT, Surgery, Physics, Artifacts, Image verification /ecr2014/C-0462 Metal Artifact Reduction Algorithm enablesreduce metal artifacts and improvement of diagnosis in the postoperative Pedicle screws implant for Spinal Fusion: A Phantom Study Poster No.: C-0462 Congress:

More information

Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time

Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time Poster No.: C-208 Congress: ECR 2009 Type: Educational Exhibit Topic: Chest Authors:

More information

Contrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760

Contrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760 Can Weight-Adapted IV Contrast Media Protocols Reduce Iodine Dose and Still Produce a Diagnostic Contrast Enhancement Level in Abdomino-Pelvic CT Scans? Poster No.: C-1760 Congress: ECR 2015 Type: Authors:

More information

Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner.

Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner. Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner. Poster No.: C-2613 Congress: ECR 2015 Type: Authors: Keywords: DOI: Scientific Exhibit

More information

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters Poster No.: C-2584 Congress: ECR 2015 Type: Scientific

More information

Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography

Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography Poster No.: C-1342 Congress: ECR 2013 Type: Scientific Exhibit Authors:

More information

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation Poster No.: C-2014 Congress: ECR 2014 Type: Educational Exhibit Authors: M. A. Ottesen; Oslo/NO Keywords: Cardiac, Arteries / Aorta, CT, CT-Angiography,

More information

Radiological features of Legionella Pneumophila Pneumonia

Radiological features of Legionella Pneumophila Pneumonia Radiological features of Legionella Pneumophila Pneumonia Poster No.: E-0048 Congress: ESTI 2012 Type: Scientific Exhibit Authors: M. Vinciguerra, L. Stefanetti, E. Teti, G. Argentieri, L. G. 1 1 1 1 1

More information

How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter

How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter Poster No.: C-0281 Congress: ECR 2013 Type: Scientific

More information

Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis

Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis Poster No.: C-1887 Congress: ECR 2016 Type: Authors: Keywords: DOI: Educational Exhibit M.

More information

Death due to Hypothermia: Postmortem Forensic Computed Tomography.

Death due to Hypothermia: Postmortem Forensic Computed Tomography. Death due to Hypothermia: Postmortem Forensic Computed Tomography. Poster No.: C-1128 Congress: ECR 2012 Type: Educational Exhibit Authors: Y. Kawasumi, A. Usui, Y. Hosokai, M. Sato, H. Saito, T. Ishibashi,

More information

PI-RADS classification: prognostic value for prostate cancer grading

PI-RADS classification: prognostic value for prostate cancer grading PI-RADS classification: prognostic value for prostate cancer grading Poster No.: C-1622 Congress: ECR 2014 Type: Scientific Exhibit Authors: I. Platzek, A. Borkowetz, T. Paulus, T. Brauer, M. Wirth, M.

More information

A time-honored but almost forgotten sign of COPD: sabersheath trachea as a marker of severe airflow obstruction

A time-honored but almost forgotten sign of COPD: sabersheath trachea as a marker of severe airflow obstruction A time-honored but almost forgotten sign of COPD: sabersheath trachea as a marker of severe airflow obstruction Poster No.: C-0958 Congress: ECR 2013 Type: Scientific Exhibit Authors: F. Ciccarese, A.

More information

Metal Artifact Reduction by Dual Energy CT

Metal Artifact Reduction by Dual Energy CT Metal Artifact Reduction by Dual Energy CT Poster No.: C-0108 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper T. Johnson, F. Bamberg, A. Dierks, H.-C. Becker, M. F. Reiser; Munich/DE

More information

3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta

3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta 3D cine PCA enables rapid and comprehensive hemodynamic assessment of the abdominal aorta Poster No.: C-1138 Congress: ECR 2013 Type: Scientific Exhibit Authors: M. Takahashi 1, Y. Takehara 2, H. Isoda

More information

CT evaluation of small bowel carcinoid tumors

CT evaluation of small bowel carcinoid tumors CT evaluation of small bowel carcinoid tumors Poster No.: C-0060 Congress: ECR 2015 Type: Educational Exhibit Authors: N. V. V. P. Costa, L. Nascimento, T. Bilhim ; Estoril/PT, PT, 1 2 3 1 2 3 Lisbon/PT

More information

Role of Dual source CT angiography and perfusion in the diagnosis of pulmonary embolism

Role of Dual source CT angiography and perfusion in the diagnosis of pulmonary embolism Role of Dual source CT angiography and perfusion in the diagnosis of pulmonary embolism Poster No.: C-1145 Congress: ECR 2011 Type: Educational Exhibit Authors: P. S. Naphade, A. A. Raut, A. keraliya,

More information

Lung cancer in patients with chronic empyema

Lung cancer in patients with chronic empyema Lung cancer in patients with chronic empyema Poster No.: P-0025 Congress: ESTI 2015 Type: Scientific Poster Authors: Y. Lee, C.-K. Park; Guri/KR Keywords: Neoplasia, Biopsy, PET-CT, CT, Thorax, Lung DOI:

More information

Multislice CT versus cone beam CT: dosimetric and image quality comparision.

Multislice CT versus cone beam CT: dosimetric and image quality comparision. Multislice CT versus cone beam CT: dosimetric and image quality comparision. Poster No.: C-2589 Congress: ECR 2015 Type: Authors: Scientific Exhibit C. Dionisi 1, A. Crispo 2, E. Stefani 3, A. Lovaglio

More information

An audit of radiation dose of 4D CT in a radiotherapy department

An audit of radiation dose of 4D CT in a radiotherapy department An audit of radiation dose of 4D CT in a radiotherapy department Poster No.: R-0097 Congress: Type: Authors: Keywords: DOI: 2014 CSM Scientific Exhibit T. Hubbard, J. Callahan, J. Cramb, R. Budd, T. Kron;

More information

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

Bottom up cardiac CT for CABG assessment to resolve breathing artefact Bottom up cardiac CT for CABG assessment to resolve breathing artefact Poster No.: C-0589 Congress: ECR 2010 Type: Educational Exhibit Topic: Cardiac Authors: P. Glass, P. Donnelly, P. Hanley, D. Higginson,

More information

Ultra-low dose CT of the acute abdomen: Spectrum of imaging findings

Ultra-low dose CT of the acute abdomen: Spectrum of imaging findings Ultra-low dose CT of the acute abdomen: Spectrum of imaging findings Poster No.: C-1452 Congress: ECR 2010 Type: Educational Exhibit Topic: GI Tract Authors: P. A. Vlachou, C. Kloeters, S. Kandel, P. Hein,

More information

Pulmonary embolism: Strategies to optimize pulmonary MDCT angiography studies

Pulmonary embolism: Strategies to optimize pulmonary MDCT angiography studies Pulmonary embolism: Strategies to optimize pulmonary MDCT angiography studies Poster No.: C-0152 Congress: ECR 2013 Type: Educational Exhibit Authors: G. Viteri, A. Garcia-lallana, I. Simon Yarza, A. Villanueva

More information

Comparison of CT findings between MDR-TB and XDR-TB

Comparison of CT findings between MDR-TB and XDR-TB Comparison of CT findings between MDR-TB and XDR-TB Poster No.: C-0757 Congress: ECR 2017 Type: Authors: Keywords: DOI: Scientific Exhibit K. Yoon, H. Soohee; Changwon-si/KR Thorax, Lung, Respiratory system,

More information

Purpose. Methods and Materials. Results

Purpose. Methods and Materials. Results Prevalence and significance of hypoattenuating hepatic lesions deemed too small to characterise: How are we following up these lesions and what are the outcomes? Poster No.: C-014 Congress: ECR 2009 Type:

More information

Whole brain CT perfusion maps with paradoxical low mean transit time to predict infarct core

Whole brain CT perfusion maps with paradoxical low mean transit time to predict infarct core Whole brain CT perfusion maps with paradoxical low mean transit time to predict infarct core Poster No.: B-292 Congress: ECR 2011 Type: Scientific Paper Topic: Neuro Authors: S. Chakraborty, M. E. Ahmad,

More information

The "whirl sign". Diagnostic accuracy for intestinal volvulus.

The whirl sign. Diagnostic accuracy for intestinal volvulus. The "whirl sign". Diagnostic accuracy for intestinal volvulus. Poster No.: C-0670 Congress: ECR 2014 Type: Scientific Exhibit Authors: M. Pire, M. Marti, A. Borobia, A. Verón; Madrid/ES Keywords: Abdomen,

More information

A more accurate method to estimate patient dose during body CT examinations with tube current modulation

A more accurate method to estimate patient dose during body CT examinations with tube current modulation A more accurate method to estimate patient dose during body CT examinations with tube current modulation Poster No.: C-0738 Congress: ECR 2014 Type: Scientific Exhibit Authors: A. Kawaguchi 1, Y. Matsunaga

More information

Shear Wave Elastography In Characterization Of Liver Tumours

Shear Wave Elastography In Characterization Of Liver Tumours Shear Wave Elastography In Characterization Of Liver Tumours Poster No.: C-1921 Congress: ECR 2014 Type: Scientific Exhibit Authors: K. L. Choong 1, B. J. J. Abdullah 1, G. Kumar 2, C. H. Yeong 1, K. L.

More information

Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT

Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT Poster No.: C-9 Congress: ECR 5 Type: Scientific Exhibit Authors: M. Nakadate, Y. Iwasa, M. Kishino, U. Tateishi;

More information

Ethanol ablation of benign thyroid cysts and predominantly cystic thyroid nodules: factors that predict outcome.

Ethanol ablation of benign thyroid cysts and predominantly cystic thyroid nodules: factors that predict outcome. Ethanol ablation of benign thyroid cysts and predominantly cystic thyroid nodules: factors that predict outcome. Poster No.: C-0322 Congress: ECR 2014 Type: Authors: Keywords: DOI: Scientific Exhibit J.

More information

Scientific Exhibit Authors: V. Moustakas, E. Karallas, K. Koutsopoulos ; Rodos/GR, 2

Scientific Exhibit Authors: V. Moustakas, E. Karallas, K. Koutsopoulos ; Rodos/GR, 2 Diagnosis of Acute Appendicitis: the role of Color Doppler Ultrasound as first-line imaging method and evaluation of the higher diagnostic performances of CT against its disadvantages. Poster No.: C-0708

More information

Purpose. Methods and Materials

Purpose. Methods and Materials Comparison of iterative and filtered back-projection image reconstruction techniques: evaluation of heavily calcified vessels with coronary CT angiography Poster No.: C-1644 Congress: ECR 2011 Type: Scientific

More information

Intraluminal gas in non-perforated acute appendicitis: a CT sign of gangrenous appendicitis

Intraluminal gas in non-perforated acute appendicitis: a CT sign of gangrenous appendicitis Intraluminal gas in non-perforated acute appendicitis: a CT sign of gangrenous appendicitis Poster No.: C-978 Congress: ECR 202 Type: Scientific Exhibit Authors: D. Plata Ariza, E. MARTINEZ CHAMORRO, J.

More information

The role of abdominal CT and MRI in detection of complications after transplantations of liver, kidney and pancreas.

The role of abdominal CT and MRI in detection of complications after transplantations of liver, kidney and pancreas. The role of abdominal CT and MRI in detection of complications after transplantations of liver, kidney and pancreas. Poster No.: C-1319 Congress: ECR 2015 Type: Educational Exhibit Authors: R. Muslimov,

More information

Cumulative radiation CT dose in young traumatic patients: a single centre 5 years retrospective review

Cumulative radiation CT dose in young traumatic patients: a single centre 5 years retrospective review Cumulative radiation CT dose in young traumatic patients: a single centre 5 years retrospective review Poster No.: C-1604 Congress: ECR 2014 Type: Scientific Exhibit Authors: S. Salerno, C. Geraci, E.

More information

Use of IV-contrast versus IV-and oral-contrast in the evaluation of abdominal pain on CT in the emergency department

Use of IV-contrast versus IV-and oral-contrast in the evaluation of abdominal pain on CT in the emergency department Use of IV-contrast versus IV-and oral-contrast in the evaluation of abdominal pain on CT in the emergency department Poster No.: B-0693 Congress: ECR 2016 Type: Authors: Scientific Paper M. Wasserman 1,

More information

CT Findings in the Elderly Lung

CT Findings in the Elderly Lung CT Findings in the Elderly Lung Poster No.: C-2498 Congress: ECR 2015 Type: Educational Exhibit Authors: P. Ananias, R. Coelho, H. M. R. Marques, O. Fernandes, M. Simões, L. Figueiredo; Lisbon/PT Keywords:

More information

Purpose. Methods and Materials

Purpose. Methods and Materials Thin-section CT findings in peripheral lung cancer of 3 cm or smaller: are there any characteristic features for predicting tumor histology or do they depend only on tumor size? Poster No.: C-1893 Congress:

More information

Single cold nodule in Graves' disease: benign vs malignant

Single cold nodule in Graves' disease: benign vs malignant Single cold nodule in Graves' disease: benign vs malignant Poster No.: C-0073 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper L. I. Sonoda, M. Halim, K. Balan; Cambridge/UK Head and neck,

More information

Pulmonary changes induced by radiotherapy. HRCT findings

Pulmonary changes induced by radiotherapy. HRCT findings Pulmonary changes induced by radiotherapy. HRCT findings Poster No.: C-2299 Congress: ECR 2015 Type: Educational Exhibit Authors: R. E. Correa Soto, M. Albert Antequera, K. Müller Campos, D. 1 2 4 3 1

More information

Dual Energy CT: a new tool in evaluation of the urinary tract stones composition in clinical practice - initial study

Dual Energy CT: a new tool in evaluation of the urinary tract stones composition in clinical practice - initial study Dual Energy CT: a new tool in evaluation of the urinary tract stones composition in clinical practice - initial study Poster No.: C-2279 Congress: ECR 2013 Type: Scientific Exhibit Authors: M. Guzi#ski,

More information

Cavitary lung lesion: Two different diagnosis with similar appearence

Cavitary lung lesion: Two different diagnosis with similar appearence Cavitary lung lesion: Two different diagnosis with similar appearence Poster No.: P-0043 Congress: ESTI 2015 Type: Educational Poster Authors: M. Yesildag, H. Kalkan, K. Ödev; Konya/TR Keywords: Infection,

More information

Small-bowel obstruction due to bezoar: CT diagnosis and characterization

Small-bowel obstruction due to bezoar: CT diagnosis and characterization Small-bowel obstruction due to bezoar: CT diagnosis and characterization Poster No.: C-1450 Congress: ECR 2013 Type: Scientific Exhibit Authors: I. lópez blasco, S. Paz Maya, R. Dosdá Muñoz, D. Soriano

More information

Utility of Variable Helical Pitch CT Scanning Technique for CT Angiography of Aortoiliac and Lower Extremity Arteries

Utility of Variable Helical Pitch CT Scanning Technique for CT Angiography of Aortoiliac and Lower Extremity Arteries Utility of Variable Helical Pitch CT Scanning Technique for CT Angiography of Aortoiliac and Lower Extremity Arteries Poster No.: C-0863 Congress: ECR 2015 Type: Scientific Exhibit Authors: A. Nakamoto,

More information

Treatment options for endoleaks: stents, embolizations and conversions

Treatment options for endoleaks: stents, embolizations and conversions Treatment options for endoleaks: stents, embolizations and conversions Poster No.: C-0861 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific Exhibit G. Lombardi; napoli/it Arteries / Aorta, Abdomen,

More information

Aetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH)

Aetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH) Aetiologies of normal CT main pulmonary arterial (PA) measurements in patients with right heart catheter (RHC) confirmed pulmonary hypertension (PH) Poster No.: C-0964 Congress: ECR 2010 Type: Scientific

More information

CT staging in sigmoid diverticulitis

CT staging in sigmoid diverticulitis CT staging in sigmoid diverticulitis Poster No.: C-1503 Congress: ECR 2012 Type: Scientific Paper Authors: M. Buchberger, B. von Rahden, J. Schmid, W. Kenn, C.-T. Germer, D. Hahn; Würzburg/DE Keywords:

More information

Overview of physiological post-mortem alterations in totalbody imaging of 100 in-hospital deceased patients

Overview of physiological post-mortem alterations in totalbody imaging of 100 in-hospital deceased patients Overview of physiological post-mortem alterations in totalbody imaging of 100 in-hospital deceased patients Poster No.: C-1234 Congress: ECR 2016 Type: Scientific Exhibit Authors: I. Wagensveld, W. Oosterhuis,

More information

Institutional review board approval was obtained prior to the start of this study.

Institutional review board approval was obtained prior to the start of this study. Lower Limb Alignment and Length Measurements - Comparison of Computed Tomography, Upright Full-Length Conventional Radiography and Upright Biplanar Linear-Low Dose X-ray Scanner Poster No.: C-1382 Congress:

More information

CT assessment of acute coalescent mastoiditis.

CT assessment of acute coalescent mastoiditis. CT assessment of acute coalescent mastoiditis. Poster No.: C-1794 Congress: ECR 2010 Type: Educational Exhibit Topic: Head and Neck Authors: A. Thomson, S. J. Thomas, A. Hutchings, E. Tilley; Portsmouth/UK

More information

Abdominal fat distribution (subcutaneous vs. visceral abdominal fat compartments): correlation with gender, age, BMI and waist circumference

Abdominal fat distribution (subcutaneous vs. visceral abdominal fat compartments): correlation with gender, age, BMI and waist circumference Abdominal fat distribution (subcutaneous vs. visceral abdominal fat compartments): correlation with gender, age, BMI and waist circumference Poster No.: C-934 Congress: ECR 202 Type: Scientific Exhibit

More information

Imaging Gorham's disease (vanishing bone)

Imaging Gorham's disease (vanishing bone) Imaging Gorham's disease (vanishing bone) Poster No.: C-2201 Congress: ECR 2010 Type: Scientific Exhibit Topic: Musculoskeletal Authors: D. Vanel, P. Ruggieri, M. Alberghini; Bologna/IT Keywords: Gorham,

More information

Evaluation and Optimization of Exposure Index in Lumbar Spine and Pelvis X-Ray

Evaluation and Optimization of Exposure Index in Lumbar Spine and Pelvis X-Ray Evaluation and Optimization of Exposure Index in Lumbar Spine and Pelvis X-Ray Poster No.: C-1492 Congress: ECR 2012 Type: Scientific Exhibit Authors: R. M. Lopes, L. H. Domingos ; Mortágua/PT, Azoia de

More information

CT-guided core needle biopsy of pulmonary lesions: a better tool for radiologist and clinician

CT-guided core needle biopsy of pulmonary lesions: a better tool for radiologist and clinician CT-guided core needle biopsy of pulmonary lesions: a better tool for radiologist and clinician Poster No.: C-2476 Congress: ECR 2018 Type: Educational Exhibit Authors: A. Kosolapov, I. Blokhin, P. Gelezhe;

More information

Idiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases

Idiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases Idiopathic dilatation of the pulmonary artery : radiographic and MDCT features in 6 cases Poster No.: P-0075 Congress: ESTI 2014 Type: Authors: Educational Poster J. J. Woo 1, K. Y. Lee 2, Y. Cho 1, J.

More information

DEXA Scores and Bone Density Measured on Routine CT Scans

DEXA Scores and Bone Density Measured on Routine CT Scans DEXA Scores and Bone Density Measured on Routine CT Scans Poster No.: R-0072 Congress: 2015 ASM Type: Scientific Exhibit Authors: C. Annabattula, P. Phadke; Sydney/AU Keywords: Screening, Nuclear medicine

More information

Emerging Referral Patterns for Whole-Body Diffusion Weighted Imaging (WB-DWI) in an Oncology Center

Emerging Referral Patterns for Whole-Body Diffusion Weighted Imaging (WB-DWI) in an Oncology Center Emerging Referral Patterns for Whole-Body Diffusion Weighted Imaging (WB-DWI) in an Oncology Center Poster No.: C-1296 Congress: ECR 2014 Type: Scientific Exhibit Authors: G. Petralia 1, G. Conte 1, S.

More information

Lung sonography in the diagnosis of pneumothorax.

Lung sonography in the diagnosis of pneumothorax. Lung sonography in the diagnosis of pneumothorax. Poster No.: C-0526 Congress: ECR 2011 Type: Educational Exhibit Authors: K. Stefanidis, K. Vintzilaios, D. D. Cokkinos, E. Antypa, S. Dimopoulos, S. Nanas,

More information

Comparison of multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and cholangiocarcinoma

Comparison of multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and cholangiocarcinoma Comparison of multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and cholangiocarcinoma Poster No.: C-0245 Congress: ECR 2014 Type: Scientific Exhibit Authors: M. Yata,

More information

Intratendinous tears of the Achilles tendon - a new pathology? Analysis of a large 4 year cohort.

Intratendinous tears of the Achilles tendon - a new pathology? Analysis of a large 4 year cohort. Intratendinous tears of the Achilles tendon - a new pathology? Analysis of a large 4 year cohort. Poster No.: C-1680 Congress: ECR 2014 Type: Scientific Exhibit Authors: S. Morton, T. Parkes, O. Chan,

More information

Assessment of Vasospasm and Delayed Cerebral Ischemia after Subarachnoid Hemorrhage: Current concepts and Value of CT Perfusion and CT Angiography

Assessment of Vasospasm and Delayed Cerebral Ischemia after Subarachnoid Hemorrhage: Current concepts and Value of CT Perfusion and CT Angiography Assessment of Vasospasm and Delayed Cerebral Ischemia after Subarachnoid Hemorrhage: Current concepts and Value of CT Perfusion and CT Angiography Poster No.: C-2563 Congress: ECR 2012 Type: Educational

More information

Radiofrequency ablation combined with conventional radiotherapy: a treatment option for patients with medically inoperable lung cancer

Radiofrequency ablation combined with conventional radiotherapy: a treatment option for patients with medically inoperable lung cancer Radiofrequency ablation combined with conventional radiotherapy: a treatment option for patients with medically inoperable lung cancer Poster No.: C-0654 Congress: ECR 2011 Type: Scientific Paper Authors:

More information

Role of positron emission mammography (PEM) for assessment of axillary lymph node status in patients with breast cancer

Role of positron emission mammography (PEM) for assessment of axillary lymph node status in patients with breast cancer Role of positron emission mammography (PEM) for assessment of axillary lymph node status in patients with breast cancer Poster No.: C-1260 Congress: ECR 2011 Type: Scientific Paper Authors: K. M. Kulkarni,

More information

Standardizing mammographic breast compression: Pressure rather than force?

Standardizing mammographic breast compression: Pressure rather than force? Standardizing mammographic breast compression: Pressure rather than force? Poster No.: C-2383 Congress: ECR 2012 Type: Authors: Scientific Paper J. E. de Groot 1, W. Branderhorst 1, M. Broeders 2, G. J.

More information