Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur ABSTRACT

Size: px
Start display at page:

Download "Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur ABSTRACT"

Transcription

1 JOURNAL OF BONE AND MINERAL RESEARCH Volume 18, Number 10, American Society for Bone and Mineral Research Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur B VAN RIETBERGEN, 1 R HUISKES, 1 F ECKSTEIN, 2 andprüegsegger 3 ABSTRACT Quantitative information about bone tissue level loading is essential for understanding bone mechanical behavior. We made microfinite element models of a healthy and osteoporotic human femur and found that tissue-level strains in the osteoporotic femoral head were 70% higher on average and less uniformly distributed than those in the healthy one. Introduction: Bone tissue stresses and strains in healthy load-adapted trabecular architectures should be distributed rather evenly, because no bone tissue is expected to be overloaded or unused. In this study, we evaluate this paradigm with the use of microfinite element ( FE) analyses to calculate tissue-level stresses and strains for the human femur. Our objectives were to quantify the strain distribution in the healthy femur, to investigate to what extent this distribution is affected by osteoporosis, to determine if osteoporotic bone is simply bone adapted to lower load levels, and to determine the safety factor for trabecular bone. Materials and Methods: FE models of a healthy and osteoporotic proximal femur were made from microcomputed tomography images. The models consisted of over 96 and 71 million elements for the healthy and osteoporotic femur, respectively, and represented their internal and external morphology in detail. Stresses and strains were calculated for each element and their distributions were calculated for a volume of interest (VOI) of trabecular bone in the femoral head. Results: The average tissue-level principal strain magnitude in the healthy VOI was microstrains and that in the osteoporotic VOI was microstrains. Calculated safety factors were 8.6 for the healthy and 4.9 for the osteoporotic femurs. After reducing the force applied to the osteoporotic model to 59%, the average strain compared with that of the healthy femur, but the SD was larger (208 microstrains). Conclusions: Strain magnitudes in the osteoporotic bone were much higher and less uniformly distributed than those in the healthy one. After simulated joint-load reduction, strain magnitudes in the osteoporotic femur were very similar to those in the healthy one, but their distribution is still wider and thus less favorable. J Bone Miner Res 2003;18: INTRODUCTION ALREADY OVER A CENTURY ago, the anatomist Meyer (1) and the engineer Culmann (2) discovered a remarkable similarity between the trabecular architecture of the proximal femur and the patterns of stress trajectories, calculated with the new theory of Graphical Statics, developed by Culmann. (2) On these results, Wolff (3) based his trajectorial theory, the match of trabecular morphology and stress trajectories and the essence of Wolff s law. Accordingly, The authors have no conflict of interest. trabecular architecture is assumed to minimize both bone stress and weight. This paradigm at least suggests that, normally, stresses and strains should be distributed rather evenly over the trabecular architecture. So far, however, there have been no possibilities for a quantitative evaluation of this paradigm. It has been argued that the premise of Wolff s law is a false one and that the correspondence between trabecular architecture and stress trajectories is just an optical illusion. (4) The Graphical Statics technique for analysis of stress transfer in solids is based on requirements for continuity of the material. The results of these analyses only tell us about the courses of the 1 Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands. 2 Institute of Anatomy, Ludwig-Maximilians-Universität, München, Germany. 3 Institute of Biomedical Engineering, University and ETH Zürich, Zürich, Switzerland. 1781

2 1782 VAN RIETBERGEN ET AL. stress trajectories if the bone would be made out of a single homogeneous and isotropic material with no trabecular architecture. It has been argued as well that the similarity between trabecular orientation and stress trajectories is circumstantial rather than causal and that there are no mathematical rules for bone architecture. (5) Over the last decades, far more advanced computational models, as based on finite element (FE) analysis, were developed to calculate stresses and strains in complex three-dimensional (3D) structures. Where analyses of bones are concerned, however, this approach still suffers from the same limitations: bone material can only be represented as a homogenized continuum. Although such methods can account for the local porosity and anisotropy of the material, they can only provide stresses and strains at the homogenized level and not those in individual trabeculae. Because of the lack of stress and strain information at this small level, it is not known if, and to what extent, even distributions are possible for the actual tissue stresses and strains, or whether this is only possible for the average tissues stresses and strains over a loading cycle. Nor is it known to what extent a potential even distribution of tissue stresses and strains is affected by structural changes caused by osteoporosis and what the safety factor of the bone is for changes in loads. In this study, we aim at finding answers to these questions by calculating bone tissue stresses and strain in the femoral head of a healthy and osteoporotic femur using high-resolution FE models that can represent individual trabeculae in the proximal end of the femur. With this technique, high-resolution sequential images obtained from, for example, microcomputed tomography ( CT) scanners are used as a basis for the geometry of a 3D FE model that can represent the trabecular structure in detail. (6) Because models generated in this way will in generally consist of a very large number of elements (on the order of /cm 3 ), special iterative FE solvers and supercomputers are generally required. (7,8) To date, this technique has only been used to analyze test samples of bone (loaded in a non-physiological way) and small animal bones because of limitations on CT scanning volume and computer resources. For the calculation of physiological tissue loading, natural boundary conditions must be applied, which is possible only when FE models can represent whole bones. With recently developed CT scanners for large pieces of bone and new parallel computers with many gigabytes of memory, this is now possible. The feasibility of this FE approach to calculate tissue level stresses and strains in human bones with this new hardware is explored here. Specific purposes of this study are to quantify and compare strain distributions in the healthy and osteoporotic femoral head, to investigate to what extent an even strain distribution can be obtained and to what extent this distribution is affected by osteoporosis, to determine if osteoporotic bone is simply bone adapted to lower load levels, and to determine the safety factor for trabecular bone. MATERIALS AND METHODS Bone mineral density (BMD) values of the femoral neck were measured (DPX-L, DXA scanner; Lunar) in situ in 80 elderly cadavers from an anatomic dissection course. Based on these measurements, a healthy femur (T-score: 0.5) and a severely osteoporotic (T-score: 4.0) femur were selected, with closely matched age (healthy, 82 years; osteoporotic, 89 years), body weight (healthy, 63 kg; osteoporotic, 57 kg), length (healthy, 1.60 m; osteoporotic, 1.61 m), and femoral head diameter (45 mm for both femurs) of the female donors. Sequential cross-sectional images of the proximal 10 cm of these femurs were made using a CT scanner ( CT80; Scanco, Bassersdorf, Switzerland) with an 80-mm field-ofview. The resolution of the images was chosen as 80 m so that the entire volume could be captured with images of pixels in size. A total of 1154 and 1152 images were made for the healthy and osteoporotic femur, respectively, covering a length of approximately 92 mm of each femur. The slice distance was chosen the same as the pixel size at 80 m. The total time needed for imaging and reconstruction was about 200 s per cross-section, resulting in a total scan time of approximately 3 days for each femur. After reconstruction of the bone in a voxel grid, a modest Gauss filtering algorithm followed by a segmentation algorithm was applied to reduce the noise and to extract the bone tissue, respectively. The resulting 3D reconstructions of the healthy and osteoporotic proximal femur represented the internal and external architecture of the bone in great detail (Fig. 1). By comparing simulated radiographs made from the computer reconstruction data (Fig. 2) with real radiographs of the bone, it was concluded that all relevant features of the bone as seen on the real radiographs were clearly recognizable in the simulated radiographs. Bone voxels were converted to equally sized brick elements, resulting in FE models with over 96.8 and 71.6 million elements and 130 and 100 million nodes for the healthy and osteoporotic femurs, respectively. In each femur, cortical and cancellous bone regions were identified based on the number of bone voxels in the neighborhood of each voxel. Elements were assigned a stiffness of 22.5 GPa for cortical and 15 GPa for trabecular bone tissue. (9,10) A physiological distributed load was applied normal to the femoral head surfaces. The radius and the center of the femoral head sphere were found by calculating the radius and center of the circle that best fits the contour of the femoral head, as seen in the simulated radiographs in three spatial directions. The direction and magnitude of the resultant external force acting on the femoral head were chosen to represent the stance phase of walking and were obtained from in vivo telemetry measurement. (11) The force magnitude was 234% of body weight (BW), corresponding to 1446N and 1308N for the healthy and osteoporotic femurs, respectively. The force was distributed normal to the surface of the femoral head with its magnitude following a cosine function of the polar angle as obtained from the telemetry data. The distal ends of both models were fully constrained.

3 TRABECULAR BONE TISSUE STRESSES AND STRAINS 1783 FIG. 1. FE models of the (A) healthy and (B) osteoporotic femurs. In the larger images, only the half-models are shown to show the trabecular bone regions. Insets: rendered image of the full model. The FE analyses were performed with an iterative element-by-element solver that was optimized for parallel processing. (7,8) Thirty processors of an SG/Cray Origin2000 computer, with a total of 128 processors and 57 GB of memory, were used for the calculations. Memory requirements were 17 GB for the healthy femur and 13 GB for the osteoporotic one. About 30,000 iterations were needed to obtain sufficiently converged results. (12) Total cpu time for solving the healthy femur model was about h, and total wall-clock time was approximately 6 weeks. For the osteoporotic model, these figures were approximately 25% less. Principal stresses and strains were calculated for each element in the model, and the component of the tissue principal strain with the largest magnitude was represented in 3D contour plots. Further analyses of tissues stresses and strains in the trabecular bone tissue concentrated on a spherical volume of interest (VOI) located within the femoral head (Fig. 2). This sphere, with a radius of 16 mm, comprises most of the trabecular bone in the femoral head of both femurs. The number of elements in this sphere was 15.3 and 8.4 million for the healthy and osteoporotic model, respectively. From these numbers, it was calculated that the trabecular bone volume fraction was 0.46 for the VOI in the healthy femur model and 0.25 for the VOI in the osteoporotic model, which clearly shows the large difference in bone density in this region. Histogram plots were created for the component of the principal strain with the largest magnitude, further indicated as i princ max, with the sign dependent on the sign of i princ and i 1, 2, or 3, representing the three components of the principal strain. The same indicators were used for the component of the principal stress with the largest magnitude, further indicated as i princ max, for the strain energy density (SED), for the Von Mises equivalent stress, indicated as VM, and for the maximal principal strain magnitude, indicated as i princ max. To check whether the osteoporotic architecture is adapted to reduced load, we investigated if the strain distribution in the osteoporotic bone would be similar to that in healthy bone for a reduced hip-joint load. For this purpose, the stress and strain calculations for the osteoporotic bone were redone after scaling the external load such that the average value of the principal strain magnitude in the VOIs was the same in the healthy and osteoporotic case. Because these are linear FE analyses, the scaling of external loading conditions can be done without performing additional FE analyses. The calculated displacements and forces could simply be scaled by the same factor, and the indices for the reduced hip-joint load were obtained by recalculation of the stress and strain values. Finally, to determine a safety factor for bone in the femoral head, we calculated the magnitude of the external load for which local bone failure would occur. For this purpose, we used a failure criterion that was developed in an earlier study of experimentally failure prediction in the human radius. (13) A good prediction of bone failure could be obtained from linear FE analyses, assuming that bone failure would occur for an external force resulting in a tissue strain distribution with 2% of the bone tissue loaded beyond 7000 microstrains. In this study, we calculated the safety factor as the number by which the external load magnitude must be multiplied to reach this tissue-level strain criterion.

4 1784 VAN RIETBERGEN ET AL. FIG. 2. Simulated radiographs of the FE models of the (A) healthy and (B) osteoporotic femurs. Grayscale represents the density in each pixel of the projection image. The same scale is used for both images. The circles drawn in the femoral heads indicate the outer dimension of the spherical VOI in each femoral head. RESULTS The contour plot for the component of the tissue principal strain with the largest magnitude i princ max in the healthy femur (Fig. 3A) shows that compression is found for trabeculae running from the femoral head to the medial cortex and tension for trabeculae in the perpendicular direction. A similar loading pattern can be observed for the osteoporotic femur (Fig. 3B), although the strains in this bone are generally higher. The average tissue-level principal strain magnitude i princ max in the healthy VOI was 304 microstrains and that for the osteoporotic VOI was 520 microstrains. Hence, to have the same average value in the healthy and osteoporotic VOIs, the magnitude of the external load working on the osteoporotic femur had to be reduced to 767N or 59% of its original value. Histograms of the bone tissue level loading distribution as represented by the parameters i princ max, i princ max, SED, VM, and i princ max in the VOI (Fig. 4) clearly show the differences between the healthy and osteoporotic femoral heads. For the osteoporotic VOI, the distribution curves are much wider, indicating that more material is subjected to high stress than for the healthy VOI. After downscaling the load to 59% of its original value (such that the average of i princ max is the same as in the healthy situation), however, the curves for the osteoporotic bone and those for the healthy bone closely match for all investigated parameters. From the average values of the parameters investigated and their SDs (Table 1), it was calculated that, on average, the stress and strain components in the osteoporotic VOI are increased by 57 71% relative to the healthy one. The increase in the SED was much larger at 208%. After reducing the magnitude of the external load applied to the osteoporotic femur to 59%, differences between the average values in the healthy and osteoporotic VOI were less than 8% for any of the parameters investigated. Nevertheless, the SDs of the parameters calculated for the osteoporotic bone were larger in all cases (by 12 25%) than in the healthy VOI. Even for parameter i princ max, which has exactly the same average value as in the healthy situation because its value was used as the reference for the load scaling, the SD was 13% higher than in the healthy case. The safety factor calculated for the healthy femur was This means that the external load magnitude of 1446N should be multiplied with a factor of 8.62, corresponding to a force magnitude of 12.5 kn, to reach a state where the tissue level strains exceed 7000 microstrains for 2% of the bone tissue. For the osteoporotic femur, this factor was much less at 4.9, corresponding to a force magnitude of 6.4 kn. For the osteoporotic femur with reduced loading, this factor was only slightly less than that for the healthy case at The corresponding magnitude of the load, however, was the same as for the osteoporotic bone; the scaling factor is increased only because the magnitude of the external load was reduced in this case. DISCUSSION One of the purposes of this study was to investigate to what extent an even distribution of tissue-level strains can

5 TRABECULAR BONE TISSUE STRESSES AND STRAINS 1785 FIG. 3. Calculated distribution of the principal strain component with the largest magnitude in the (A) healthy and the (B) osteoporotic femurs for a physiological joint force representing the stance-phase of walking. Yellow-to-red represent increasing compressive strains; blue-to-green, increasing tensile strains. FIG. 4. Histograms of the (A) maximum principal strain, (B) the maximum principal stress, (C) strain energy density, (D) von Mises equivalent stress, and (E) maximum principal strain magnitude for the VOI in the femoral heads. Thick white lines represent results for the healthy femur, thick black lines for the osteoporotic femur, and narrow black lines for the osteoporotic femur after reducing the joint force until the average strain was the same as in the healthy case.

6 1786 VAN RIETBERGEN ET AL. TABLE 1. STATISTICAL DESCRIPTION OF THE DISTRIBUTIONS FOUND FOR THE INVESTIGATED PARAMETERS Average SD Minimum 1st quartile Median 3rd quartile Maximum Skewness Curtosis eps_p_max ( strain) Healthy Osteoporotic Osteoporotic red. load sig_p_max (Mpa) Healthy Osteoporotic Osteoporotic red. load SED (Jm 3 ) Healthy Osteoporotic Osteoporotic red. load VM (Mpa) Healthy Osteoporotic Osteoporotic red. load eps_p_max ( strain) Healthy Osteoporotic Osteoporotic red. load be expected for a single external load case. From the results obtained, it is clear that there is considerable variation in the tissue strains for the most common and largest external load (the stance phase of walking) working on the femoral head. Obviously, a perfectly even distribution cannot be expected for one single load case because the femur is subjected to varying loading magnitudes and directions during normal daily activities. The actual trabecular structure that is caused by load adaptive remodeling should reflect all these different loading configurations in a weighted manner. In this light, the distribution found in this study is surprisingly small. Less than 2% of the tissue is loaded below 50 microstrains, and only % of the tissue is loaded beyond 3000 microstrains. The tissue-level stress and strain distributions calculated in this study compare very well to those obtained in an earlier study of a beagle femur. (14) The average strain magnitude calculated in this study (304 microstrains) is only 8.9% higher than that calculated for the beagle (279 microstrains). The average Von Mises stress and strain energy density found in the present study were 4.66 MPa and 1011 Jm 3, respectively, which are almost the same as in the canine study (4.60 MPa and 1020 Jm 3, respectively). It is interesting to note that the SDs for the strain magnitude in the canine femur (212 microstrains) are higher than those found in the present study (139 microstrains). This could be explained by the fact that magnitudes and directions of joint loads in the dog vary much more than those in humans. (15) It should be noted at this point that the sample size for each of the investigated distributions is very large, and that, accordingly, any suitable statistical test would indicate that average values differ significantly in case that these are only a fraction apart. However, statistical analyses are not very useful here because we have only analyzed one healthy and one osteoporotic bone. Hence, our results are exemplary. A second purpose was to investigate to what extent the stress and strain distribution would be affected by osteoporosis. The strain distribution in the osteoporotic femur was less favorable than that in the healthy femur, with strains 70% higher on average, and with a much higher (though still small) fraction of the tissue (0.045%) loaded beyond 3000 microstrains. Interestingly, the amount of low-loaded bone with a strain magnitude less than 50 microstrains (2.63%) was higher in the osteoporotic than in the healthy bone (1.98%), suggesting that osteoporosis does lead to the formation of loose trabecular ends. A third purpose of this study was to determine if osteoporotic bone is simply bone adapted to reduced load levels. To obtain the same average tissue level strain magnitudes, the external load applied to the osteoporotic femoral head had to be reduced considerably to 59% of its original value. After this load reduction, the histograms of all investigated parameters were very similar to those of the healthy femoral head, although the distributions were still somewhat wider, as indicated by the larger SDs. It is worth noting, however, that the amount of low-loaded bone with a strain magnitude less than 50 microstrains (4.69%) is more than twice as high as in the healthy case (1.98%), indicating that after this load reduction an increased amount of bone would be subjected to very small strains. Hence, although the tissue stress and strain distributions after load reduction look very similar to those of the healthy femur, the larger SDs and the larger amount of low-loaded bone indicate that osteoporotic bone is not the same as healthy bone adapted to lower loads. Following the paradigm that, normally, stresses and strains should be distributed rather evenly over the trabecular architecture, the larger SD found for the osteoporotic bone seems unfavorable. The interpretation of these findings also depends on the physical activities of both donors, which unfortunately were not known. If both donors were equally

7 TRABECULAR BONE TISSUE STRESSES AND STRAINS 1787 active, the load magnitudes originally applied to the FE models, which were based on in vivo telemetry measurements in active subjects, should be realistic. In this case, the bone of the osteoporotic donor is clearly higher loaded and will be more susceptible to fractures. It is possible, however, that the osteoporotic donor was (much) less active than the healthy one, such that (part of) the osteoporotic bone loss is caused by adaptation to lower load levels. In this case, the FE analyses with the reduced load would be more appropriate, and the bone loading during normal activities would be very similar to the healthy femur. It should be noted, however, that also in the latter case, the bone of the osteoporotic donor would be much more susceptible to fractures caused by non-physiological forces, such as falls, where the forces are largely determined by body weight, which was similar for both subjects. A final purpose of this study was to establish a safety factor for trabecular bone in the human femur. We calculated a safety factor of 8.62 for the healthy bone and a factor of 4.90 for the osteoporotic bone. These values correspond to 20 times BW and 11.5 times BW for the healthy and osteoporotic femur, respectively. In their study, Bergmann et al. (11) reported a maximum load magnitude measured during all measurements of 8.7 times BW (for stumbling). This indicates that the bone in the femoral head is unlikely to fracture for any of the activities that have been measured in these studies, including stumbling. It should be noted, however, that femoral fractures usually do not occur in he femoral head but rather in the neck or trochanteric region and usually are not caused by physiological loading, but to an unusual load, such as in a fall. As such, the numbers that we mention here are not directly representative for the bone fracture risk, but they are an indication for the safety factor of bone in the femoral head for physiological loading conditions. Some limitations of this study should be mentioned. First, muscle forces were not included in the model. However, their net effect is included in the joint force because these were based on in vivo measurements. Hence, stresses and strains in the femoral head and neck, which are determined only by the joint force, are correct. In the trochanteric and more distal regions, however, the muscle forces will contribute to the stresses and strains as well. Hence, the results as represented in Fig. 3 represent physiological values in the femoral head and neck that are determined by the joint force alone, but do not represent physiological values in other regions that are determined by the muscle forces as well. Second, in this study, we have assumed that the tissue level material properties in the healthy and osteoporotic situation are the same. This assumption is supported by recent studies that reported no significant changes in bone tissue material properties with osteoporosis. (16 18) It is possible to simply scale the results of the osteoporotic analyses to accommodate for changes in material behavior as long as these take place uniformly. For example, a 10% higher modulus in the osteoporotic case would result in 10% lower strains in the tissue. Third, numerical errors and the relatively large 80- m voxel size can limit the accuracy of the FE models. (19) However, earlier convergence studies have indicated that high-resolution FE models with an element size of 80 m can produce accurate calculations in the femoral head. (20,21) Although local errors in the strains might exist, in particular near the surface of the trabeculae, their effects on histograms and plots are small. (7,14) Fourth, we used linear elastic FE analyses to predict bone failure. In an earlier study, using similar FE analyses in combination with experimental data provided good results for the prediction of the bone failure load measured in experiments. (13) The concept that bone failure would occur as soon as 2% of the tissue is overloaded also agrees with findings by others, who used nonlinear FE to predict bone yield behavior. (22,23) Nevertheless, it is not known if the same values would provide similar results for bone at other sites. The values reported here thus can only be used as a first estimate of the actual failure load. Finally, computational requirements for these analyses are still excessive. The equivalent of 2.9 years of cpu-time was used for each of the analyses. Consequently, large parallel computer systems are required to perform these analyses in a reasonable amount of wall-clock time. ACKNOWLEDGMENTS This study was supported by an ETH research grant. We thank Dr Bruno Koller from Scanco Medical (Bassersdorf, Switzerland) for making the CT scans of the bones. REFERENCES 1. Meyer GH 1867 Archief fur den anatomische und physiologischen Wissenschaften im Medizin. Die Architektur der Spongiosa 34: Culmann K 1866 Die Graphische Statik. Verlag von Meyer & Zeller, Zürich, Switzerland. 3. Wolff J 1892 Das gesetz der Transformation de Knochen. Hirschwald, Berlin, Germany. 4. Cowin SC 1997 The false premise of Wolff s law. Forma 12: Huiskes R 2000 If bone is the answer, then what is the question? J Anat 197: Hollister SJ, Brennan JM, Kikuchi N 1994 A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress. J Biomech 27: van Rietbergen B, Weinans H, Huiskes R, Odgaard A 1995 A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. J Biomech 28: van Rietbergen B, Weinans H, Polman BJW, Huiskes R 1996 Computational strategies for iterative solutions of large FEM applications employing voxel data. Int J Num Meth Eng 39: Rho JY, Ashman RB, Turner CH 1993 Young s modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements. J Biomech 26: Turner CH, Rho J, Takano Y, Tsui TY, Pharr GM 1999 The elastic properties of trabecular and cortical bone tissues are similar: Results from two microscopic measurement techniques. J Biomech 32: Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN 2001 Hip contact forces and gait patterns from routine activities. J Biomech 34: van Rietbergen B, Eckstein F, Koller B, Huiskes R, Baaijens FPT, Rüegsegger P 1999 Feasibility of micro-fe analyses of human bones. In: Middleton J, Jones ML, Shrive NG, Pande GN (eds.) Computer Methods in Biomechanics and Biomedical Engineering. Gordon and Breach Science Publishers, London, UK, pp Pistoia W, van Rietbergen B, Lochmuller EM, Lill CA, Eckstein F, Ruegsegger P 2002 Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images. Bone 30:

8 1788 VAN RIETBERGEN ET AL. 14. van Rietbergen B, Muller R, Ulrich D, Ruegsegger P, Huiskes R 1999 Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions. J Biomech 32: Bergmann G, Siraky J, Rohlmann A, Koelbel R 1984 A comparison of hip joint forces in sheep, dog and man. J Biomech 17: Homminga J, McCreadie BR, Ciarelli TE, Weinans H, Goldstein SA, Huiskes R 2002 Cancellous bone mechanical properties from normals and patients with hip fractures differ on the structure level, not on the bone hard tissue level. Bone 30: Ding M 2000 Age variations in the properties of human tibial trabecular bone and cartilage. Acta Orthop Scand Suppl 292: Guo XE, Goldstein SA 2000 Vertebral trabecular bone microscopic tissue elastic modulus and hardness do not change in ovariectomized rats. J Orthop Res 18: Guldberg RE, Hollister SJ, Charras GT 1998 The accuracy of digital image-based finite element models. J Biomech Eng 120: Ulrich D, van Rietbergen B, Weinans H, Ruegsegger P 1998 Finite element analysis of trabecular bone structure: A comparison of image-based meshing techniques. J Biomech 31: Pistoia W, van Rietbergen B, Laib A, Ruegsegger P 2001 Highresolution three-dimensional-pqct images can be an adequate basis for in-vivo microfe analysis of bone. J Biomech Eng 123: Niebur GL, Yuen JC, Hsia AC, Keaveny TM 1999 Convergence behavior of high-resolution finite element models of trabecular bone. J Biomech Eng 121: Niebur GL, Feldstein MJ, Yuen JC, Chen TJ, Keaveny TM 2000 High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. J Biomech 33: Address reprint requests to: B van Rietbergen, PhD Faculty of Biomedical Engineering Eindhoven University of Technology PO Box MB Eindhoven, The Netherlands b.v.rietbergen@tue.nl Received in original form November 13, 2002; in revised form March 7, 2003; accepted May 7, 2003.

Load distribution in the healthy and osteoporotic human proximal femur during a fall to the side

Load distribution in the healthy and osteoporotic human proximal femur during a fall to the side Bone 42 (2008) 30 35 www.elsevier.com/locate/bone Load distribution in the healthy and osteoporotic human proximal femur during a fall to the side E. Verhulp, B. van Rietbergen, R. Huiskes Department of

More information

W. PISTOIA, 1 B. VAN RIETBERGEN, 2 E.-M. LOCHMÜLLER, 3 C. A. LILL, 4,5 F. ECKSTEIN, 6 and P. RÜEGSEGGER 1

W. PISTOIA, 1 B. VAN RIETBERGEN, 2 E.-M. LOCHMÜLLER, 3 C. A. LILL, 4,5 F. ECKSTEIN, 6 and P. RÜEGSEGGER 1 Estimation of Distal Radius Failure Load With Micro-Finite Element Analysis Models Based on Three-dimensional Peripheral Quantitative Computed Tomography Images W. PISTOIA, 1 B. VAN RIETBERGEN, 2 E.-M.

More information

Variations in mineralization affect the stress and strain distributions in cortical and trabecular bone

Variations in mineralization affect the stress and strain distributions in cortical and trabecular bone ARTICLE IN PRESS Journal of Biomechanics 40 (2007) 1211 1218 www.elsevier.com/locate/jbiomech www.jbiomech.com Variations in mineralization affect the stress and strain distributions in cortical and trabecular

More information

An effort is made to analyse the stresses experienced by the human femur. In order

An effort is made to analyse the stresses experienced by the human femur. In order Finite Element Analysis of Human Femur Bone U N Mughal 1, H A Khawaja 2*, M Moatamedi 1, M Souli 3 1. Narvik University College, Norway 2. UiT-The Arctic University of Norway, Norway 3. University of Lille,

More information

Number Crunching: How and When Will Numerical Models Be Used in the Clinical

Number Crunching: How and When Will Numerical Models Be Used in the Clinical Number Crunching: How and When Will Numerical Models Be Used in the Clinical Setting? W. Brent Edwards and Karen L. Troy Corresponding Author: Karen L. Troy University of Illinois at Chicago, Musculoskeletal

More information

DEVELOPMENT AND VALIDATION OF ROBUST 3D -SOLID MODEL OF HUMAN FEMUR USING CT DATA

DEVELOPMENT AND VALIDATION OF ROBUST 3D -SOLID MODEL OF HUMAN FEMUR USING CT DATA DEVELOPMENT AND VALIDATION OF ROBUST 3D -SOLID MODEL OF HUMAN FEMUR USING CT DATA 1 NISHANT KUMAR SINGH, 2 RICHA BRARU, 3 SANJAY KUMAR RAI 1 Research Scholar, School of Biomedical Engineering, IIT (BHU),

More information

HIP JOINT CONTACT PRESSURE DISTRIBUTION PRIOR AND AFTER TRIPLE OSTEOTOMY

HIP JOINT CONTACT PRESSURE DISTRIBUTION PRIOR AND AFTER TRIPLE OSTEOTOMY 148 Paper presented at Bucharest, Romania HIP JOINT CONTACT PRESSURE DISTRIBUTION PRIOR AND AFTER TRIPLE OSTEOTOMY Tiberiu LAURIAN 1), Lucian MARINCA 2), Andrei TUDOR 1), Felix PÂRVU 1) 1) POLITEHNICA

More information

Topology optimisation of hip prosthesis to reduce stress shielding

Topology optimisation of hip prosthesis to reduce stress shielding Computer Aided Optimum Design in Engineering IX 257 Topology optimisation of hip prosthesis to reduce stress shielding S. Shuib 1, M. I. Z. Ridzwan 1, A. Y. Hassan 1 & M. N. M. Ibrahim 2 1 School of Mechanical

More information

Biomechanical Analysis of Hip Joint Arthroplasties using CT-Image Based Finite Element Method

Biomechanical Analysis of Hip Joint Arthroplasties using CT-Image Based Finite Element Method Research Article Biomechanical Analysis of Hip Joint Arthroplasties using CT-Image Based Finite Element Method Mitsugu Todo * Research Institute for Applied Mechanics, Kyushu University, Kasuga, Japan

More information

Regional Distribution of Stress on the Distal Femur in Advanced Osteoarthritis

Regional Distribution of Stress on the Distal Femur in Advanced Osteoarthritis J Bone Metab 2018;25(3):175-180 https://doi.org/10.11005/jbm.2018.25.3.175 pissn 2287-6375 eissn 2287-7029 Original Article Regional Distribution of Stress on the Distal Femur in Advanced Osteoarthritis

More information

Finite Element Analysis of Radius and Ulna. Eli Pavlatos April 24, 2013

Finite Element Analysis of Radius and Ulna. Eli Pavlatos April 24, 2013 Finite Element Analysis of Radius and Ulna Eli Pavlatos April 24, 2013 Outline Review bone biomechanics bone behavior during fracture Stress analysis concepts properties of bone for models Fracture simulations

More information

MECHANICAL PROPERTIES OF A SINGLE CANCELLOUS BONE TRABECULAE TAKEN FROM BOVINE FEMUR

MECHANICAL PROPERTIES OF A SINGLE CANCELLOUS BONE TRABECULAE TAKEN FROM BOVINE FEMUR Advanced Materials Development and Performance (AMDP2011) International Journal of Modern Physics: Conference Series Vol. 6 (2012) 349-354 World Scientific Publishing Company DOI: 10.1142/S201019451200342X

More information

Journal of Biomechanical Science and Engineering

Journal of Biomechanical Science and Engineering 0123456789 Bulletin of the JSME Vol.9, No.2, 2014 Journal of Biomechanical Science and Engineering Finite element analysis of hip joint cartilage reproduced from real bone surface geometry based on 3D-CT

More information

CT Imaging of skeleton in small animals. Massimo Marenzana

CT Imaging of skeleton in small animals. Massimo Marenzana CT Imaging of skeleton in small animals Massimo Marenzana Introduction Osteoporosis is a disease in which bones become fragile and more likely to break. It can be defined as a systemic skeletal disease

More information

International Journal of Engineering Research and Development e A Mathematical Model to Calculate Contact Stresses In Artificial Human Hip Joint

International Journal of Engineering Research and Development e A Mathematical Model to Calculate Contact Stresses In Artificial Human Hip Joint International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 6, Issue 12 (May 2013), PP. 119-123 A Mathematical Model to Calculate Contact Stresses

More information

NANOINDENTATION STUDY OF NORMAL AND OSTEOPOROTIC BONES

NANOINDENTATION STUDY OF NORMAL AND OSTEOPOROTIC BONES NANOINDENTATION STUDY OF NORMAL AND OSTEOPOROTIC BONES C.T. Lim, B.H.B. Omar and J.C.J. Goh 1 Division of Bioengineering & Department of Mechanical Engineering, 1 Department of Orthopaedic Surgery, National

More information

Micro-CT imaging of surgical screw tightening in human trabecular bone

Micro-CT imaging of surgical screw tightening in human trabecular bone Micro-CT imaging of surgical screw tightening in human trabecular bone E. Perilli 1, M. Ryan 1, R. Ab-Lazid 1, J.J. Costi 1, K.J. Reynolds 1 1 Medical Device Research Institute, School of Computer Science,

More information

Stress Distribution in Human Tibia Bones using Finite Element Analysis

Stress Distribution in Human Tibia Bones using Finite Element Analysis Article Stress Distribution in Human Tibia Bones using Finite Element Analysis Wanchalerm Tarapoom a and Tumrong Puttapitukporn b,* Department of Mechanical Engineering, Faculty of Engineering, Kasetsart

More information

Effect of the femoral stem size on femur bone quality towards THR

Effect of the femoral stem size on femur bone quality towards THR Original article: Effect of the femoral stem size on femur bone quality towards THR Palash Kumar Maji a,*, Amit Roy Chowdhury b, Debasis Datta b, S Karmakar a, Subhomoy Chatterjee b and A K Prasad a a

More information

S. N. Khan 1, R. M. Warkhedkar 2, A. Shyam 3, B. R. Patil 4

S. N. Khan 1, R. M. Warkhedkar 2, A. Shyam 3, B. R. Patil 4 IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN(e) : 2278-1684, ISSN(p) : 2320 334X, PP : 40-44 www.iosrjournals.org Correlation between BMD and Radio intensity of Human Bones for Strength

More information

In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics.

In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics. In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics. Chandrasenan.P 1, Vishnu.G 2, Akshay K Nair 3 1M Tech student, Department of Mechanical

More information

Previous studies have shown that low-density,

Previous studies have shown that low-density, Mutual associations among microstructural, physical and mechanical properties of human cancellous bone Ming Ding, Anders Odgaard, Carl Christian Danielsen, Ivan Hvid From Aarhus University Hospital, Aarhus,

More information

Thickness Computation Under In-Vivo Trabecular Bone CT Imaging

Thickness Computation Under In-Vivo Trabecular Bone CT Imaging Thickness Computation Under In-Vivo Trabecular Bone CT Imaging Gokul. S PG Scholar,M.E - II year Department of Computer Science and Engineering Jansons Institute of Technology Coimbatore, Tamilnadu Aarthi.K

More information

Comparative Study of Fixation Devices for Intertrochanteric Fractures

Comparative Study of Fixation Devices for Intertrochanteric Fractures Comparative Study of Fixation Devices for Intertrochanteric Fractures C. Sticlaru * A. Davidescu Politehnica University of Timişoara Politehnica University of Timişoara Timişoara, România Timişoara, România

More information

INTACT AND IMPLANTED FEMUR BEHAVIOUR DURING WALKING AND JOGGING

INTACT AND IMPLANTED FEMUR BEHAVIOUR DURING WALKING AND JOGGING 1 from 4 INTACT AND IMPLANTED FEMUR BEHAVIOUR DURING WALKING AND JOGGING V. A. Papathanasopoulou 1, D. I. Fotiadis 2 and C.V. Massalas 3 1 Dept. of Medical Physics, Medical School, University of Ioannina,

More information

Comparative study of the contact pressures in hip joint models with femoroacetabular impingment with different cephalic deformities

Comparative study of the contact pressures in hip joint models with femoroacetabular impingment with different cephalic deformities Comparative study of the contact pressures in hip joint models with femoroacetabular impingment with different cephalic deformities Iryna Havenko Instituto Superior Técnico, Universidade de Lisboa, Portugal

More information

3D Morphological Tumor Analysis Based on Magnetic Resonance Images

3D Morphological Tumor Analysis Based on Magnetic Resonance Images 3D Morphological Tumor Analysis Based on Magnetic Resonance Images Sirwoo Kim Georgia Institute of Technology The Wallace H. Coulter Department of Biomedical Engineering, Georgia. Abstract In this paper,

More information

Dynamic Finite Element Analysis of Impulsive Stress Waves Propagating from the Greater Trochanter of the Femur by a Sideways Fall

Dynamic Finite Element Analysis of Impulsive Stress Waves Propagating from the Greater Trochanter of the Femur by a Sideways Fall 215 9 3 15171 Dynamic Finite Element Analysis of Impulsive Stress Waves Propagating from the Greater Trochanter of the Femur by a Sideways Fall a* b a b 1 9 3 ʼ ɵ ɸ ɵ ɸ ɵ ɸ ɵ ɸ (A (B Sideways fall configuration.

More information

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment Bone Investigational Toolkit BIT TM Biomechanical Bone Integrity Assessment The Bone Densitometry Problem Modeling of cortical shell failure with third-party engineering models. Bone densitometry is widely

More information

Thomas A. Metzger, Stephen A. Schwaner, Jonelle M. Shudick, Anthony J. LaNeve, Glen L. Niebur. University of Notre Dame, Notre Dame, IN, USA.

Thomas A. Metzger, Stephen A. Schwaner, Jonelle M. Shudick, Anthony J. LaNeve, Glen L. Niebur. University of Notre Dame, Notre Dame, IN, USA. Mechanical Stimuli in Bone Marrow During Physiologic Loading Thomas A. Metzger, Stephen A. Schwaner, Jonelle M. Shudick, Anthony J. LaNeve, Glen L. Niebur. University of Notre Dame, Notre Dame, IN, USA.

More information

FEA of a proximal humerus fracture with a fixation plate

FEA of a proximal humerus fracture with a fixation plate FEA of a proximal humerus fracture with a fixation plate 1 University of Exeter, Exeter, UK P. Young 1, J. Kennedy 2, R.Cotton 3, 2 University College Dublin, Dublin, Ireland. 3 Simpleware Ltd., Exeter,

More information

CONTRACTING ORGANIZATION: Spaulding Rehabilitation Hospital, Boston, MA 02129

CONTRACTING ORGANIZATION: Spaulding Rehabilitation Hospital, Boston, MA 02129 AD Award Number: W81XWH-10-1-1043 TITLE: FES-Rowing versus Zoledronic Acid to Improve Bone Health in SCI PRINCIPAL INVESTIGATOR: Leslie R. Morse, DO CONTRACTING ORGANIZATION: Spaulding Rehabilitation Hospital,

More information

Assessing Bone Quality in Terms of Bone Mineral Density, Buckling Ratio and Critical Fracture Load

Assessing Bone Quality in Terms of Bone Mineral Density, Buckling Ratio and Critical Fracture Load J Bone Metab 01;1:- http://dx.doi.org/10.1100/jbm.01.1.. pissn - eissn -0 Original Article Assessing Bone Quality in Terms of Bone Mineral Density, Buckling Ratio and Critical Fracture Load Anitha D 1,

More information

A DAMAGE/REPAIR MODEL FOR ALVEOLAR BONE REMODELING

A DAMAGE/REPAIR MODEL FOR ALVEOLAR BONE REMODELING A DAMAGE/REPAIR MODEL FOR ALVEOLAR BONE REMODELING M. Mengoni 1 and J.-P. Ponthot 2 1. ABSTRACT Tooth movements obtained through orthodontic appliances result from a complex biochemical process of bone

More information

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis Miriam Chaudhary, M.Sc. 1, Peter S. Walker, PhD 2. 1 NYU Hospital for Joint Diseases, New York City, NY, USA, 2 NYU-Hospital

More information

Prediction Of Pathological Fracture In The Proximal Femora With Bone Lesions Using A CT Scan-based Finite Element Method

Prediction Of Pathological Fracture In The Proximal Femora With Bone Lesions Using A CT Scan-based Finite Element Method Prediction Of Pathological Fracture In The Proximal Femora With Bone Lesions Using A CT Scan-based Finite Element Method Yusuke Kawabata 1, Kosuke Matsuo 2, Hiroyuki Ike, MD 2, Tomoyuki Saito, MD, PhD

More information

# % # & # # ( # ) # % # # ) +,#. # ) / ) 3 ) ) 7 55, # 09 /:2 ;88% 111 <!= <01 9<1:<:1:==

# % # & # # ( # ) # % # # ) +,#. # ) / ) 3 ) ) 7 55, # 09 /:2 ;88% 111 <!= <01 9<1:<:1:== ! # % # & # # ( # ) # % # # ) +,#. # ) /01 2 + ) 3 ) 4 5 6 ) 7 55, 5 8 3 # 09 /:2 ;88% 111 This is the accepted version of the following article: Joshua N. Farr, Wei Zhang, Shaji

More information

Static and Dynamic Load on Hip Contact of Hip Prosthesis and Thai Femoral Bones K. Chalernpon, P. Aroonjarattham, K.

Static and Dynamic Load on Hip Contact of Hip Prosthesis and Thai Femoral Bones K. Chalernpon, P. Aroonjarattham, K. Static and Dynamic Load on Hip Contact of Hip Prosthesis and Thai Femoral Bones K. Chalernpon, P. Aroonjarattham, K. Aroonjarattham International Science Index, Mechanical and Mechatronics Engineering

More information

Engineering Approaches to Age-related Diseases

Engineering Approaches to Age-related Diseases Keynote Paper Engineering Approaches to Age-related Diseases *Taeyong Lee 1), D Anitha 2), Jee Chin Teoh 3) 1), 2), 3) Department of Bioengineering, National University of Singapore, 9 Engineering Drive

More information

Numerical evaluation of bone remodelling associated with trans-femoral osseointegration implant - a 68 month follow-up study

Numerical evaluation of bone remodelling associated with trans-femoral osseointegration implant - a 68 month follow-up study Title Page & Abstract Numerical evaluation of bone remodelling associated with trans-femoral osseointegration implant - a 68 month follow-up study D H Xu 1, A D Crocombe 2, W Xu* 2 1 Department of Orthopaedics

More information

Beyond BMD: Bone Quality and Bone Strength

Beyond BMD: Bone Quality and Bone Strength Beyond BMD: Bone Quality and Bone Strength Mary L. Bouxsein, PhD Center for Advanced Orthopedic Studies Department of Orthopedic Surgery, Harvard Medical School MIT-Harvard Health Sciences and Technology

More information

Keywords: Angioplasty, Explicit finite elements method, Tube hidroforming, Stents.

Keywords: Angioplasty, Explicit finite elements method, Tube hidroforming, Stents. Blucher Mechanical Engineering Proceedings May 2014, vol. 1, num. 1 www.proceedings.blucher.com.br/evento/10wccm AN ANALYSIS OF THE CONTACT BETWEEN THE STENT AND THE ARTERY USING TUBE HIDROFORMING SIMULATION

More information

Original Article. Kazuhiro Imai. Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, Tokyo, Japan

Original Article. Kazuhiro Imai. Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, Tokyo, Japan Aging and Disease www.aginganddisease.org Volume 6, Number 3; 180-187, June 2015 http://dx.doi.org/10.14336/ad.2014.0621 Original Article Analysis of Vertebral Bone Strength, Fracture Pattern, and Fracture

More information

The Mechanical Behavior of Bone Cement in THR in the Presence of Cavities

The Mechanical Behavior of Bone Cement in THR in the Presence of Cavities Engineering, Technology & Applied Science Research Vol. 4, No. 3, 2014, 625-630 625 The Mechanical Behavior of Bone Cement in THR in the Presence of Cavities A. Benouis Mechanical Engineering Department

More information

Modelling of temporomandibular joint and FEM analysis

Modelling of temporomandibular joint and FEM analysis Acta of Bioengineering and Biomechanics Vol. 8, No. 1, 2006 Modelling of temporomandibular joint and FEM analysis MARTINA FRIOVÁ, ZDENK HORÁK, SVATAVA KONVIKOVÁ Laboratory of Biomechanics, Department of

More information

Finite-element study of vibration effect to fracture healing of a human tibia

Finite-element study of vibration effect to fracture healing of a human tibia Finite-element study of vibration effect to fracture healing of a human tibia Leonid Maslov 1, Jean-Baptiste Etheve 2, Nikolay Sabaneev 3 Ivanovo State Power Engineering University, Ivanovo, Russia 1 Corresponding

More information

Trabecular bone analysis with tomosynthesis in diabetic patients: comparison with CT-based finite-element method

Trabecular bone analysis with tomosynthesis in diabetic patients: comparison with CT-based finite-element method Trabecular bone analysis with tomosynthesis in diabetic patients: comparison with CT-based finite-element method Poster No.: C-1789 Congress: ECR 2015 Type: Scientific Exhibit Authors: M. Fujii, T. Aoki,

More information

Introduction to Biomedical Engineering: Basic concepts and Bone Biomechanics

Introduction to Biomedical Engineering: Basic concepts and Bone Biomechanics Introduction to Biomedical Engineering: Basic concepts and Bone Biomechanics Fall 2016, AKUT G. Rouhi Biomechanics The field of biomechanics applies principles of mechanics to study the structure and function

More information

ME/BioE C176 Final Exam, Fall 2001

ME/BioE C176 Final Exam, Fall 2001 Saturday, December 15, 8:00 11:00 AM, 2001. Answer all questions for a maximum of 100 points. Please write all answers in the space provided. If you need additional space, write on the back sides. Indicate

More information

Hierarchical Microimaging of Bone Structure and Function

Hierarchical Microimaging of Bone Structure and Function Hierarchical Microimaging of Bone Structure and Function Prof. Ralph Müller, PhD Institute for Biomechanics, ETH Zürich, Zürich, Switzerland 1 Motivation and aims Engineering endpoints have become an important

More information

Evaluation of the Potential Clinical Application of Low-Intensity Ultrasound Stimulation for Preventing Osteoporotic Bone Fracture

Evaluation of the Potential Clinical Application of Low-Intensity Ultrasound Stimulation for Preventing Osteoporotic Bone Fracture Annals of Biomedical Engineering, Vol. 38, No. 7, July 21 (Ó 21) pp. 2438 2446 DOI: 1.17/s1439-1-9983-8 Evaluation of the Potential Clinical Application of Low-Intensity Ultrasound Stimulation for Preventing

More information

Introduction. Original Article. Abstract

Introduction. Original Article. Abstract J Musculoskel Neuron Interact 2004; 4(2):152-158 Original Article Hylonome Loading simulation of lumbar spine vertebrae during a compression test using the finite elements method and trabecular bone strength

More information

Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis

Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis 1 Research Article Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis Aswin Yodrux* Department of Materials Handling and Logistics for Engineering,

More information

/mhj. Relationship between the hip-joint loading and the capital epiphyseal growth plate orientation. Y.H. Sniekers BMTE 02.17

/mhj. Relationship between the hip-joint loading and the capital epiphyseal growth plate orientation. Y.H. Sniekers BMTE 02.17 Relationship between the hip-joint loading and the capital epiphyseal growth plate orientation Y.H. Sniekers BMTE.7 Supervisors: Wouter Wilson Rik Huiskes Eindhoven, May /mhj Relationship between the hip-joint

More information

Observations on the Geometric Distribution of Micro-structural Features in Cortical Bone

Observations on the Geometric Distribution of Micro-structural Features in Cortical Bone Observations on the Geometric Distribution of Micro-structural Features in Cortical Bone I. S. Hage, R. F. Hamade Abstract This paper reports on observations of the distribution of micro-structural features

More information

Beyond BMD: Bone Quality and Bone Strength

Beyond BMD: Bone Quality and Bone Strength Beyond BMD: Bone Quality and Bone Strength Consultant / advisor: Amgen, Eli Lilly, Merck Disclosures Mary L. Bouxsein, PhD Beth Israel Deaconess Medical Center Harvard Medical School, Boston, MA mbouxsei@bidmc.harvard.edu

More information

Prediction of the Trabecular Architecture and Its Potential Variation. (Remodeling) on the Glenoid of the Glenohumeral (GH) Joint.

Prediction of the Trabecular Architecture and Its Potential Variation. (Remodeling) on the Glenoid of the Glenohumeral (GH) Joint. Prediction of the Trabecular Architecture and Its Potential Variation (Remodeling) on the Glenoid of the Glenohumeral (GH) Joint A Thesis Submitted to the Faculty of Drexel University by Dohyung Lim in

More information

Bone mechanics bone strength and beyond

Bone mechanics bone strength and beyond Bone mechanics bone strength and beyond Tim Arnett Bone Curriculum Symposium 2018 Department of Cell & Developmental Biology University College London Factors affecting bone strength Mass Architectural

More information

Modélisation par éléments finis des effets des médicaments sur le remodelage osseux : Approche mécanobiologique

Modélisation par éléments finis des effets des médicaments sur le remodelage osseux : Approche mécanobiologique Modélisation par éléments finis des effets des médicaments sur le remodelage osseux : Approche mécanobiologique Ridha Hambli Prisme Institute 8, Rue Léonard de Vinci, 45072 Orléans cedex 2, France Phone

More information

Investigating the loading behaviour of intact and meniscectomy knee joints and the impact on surgical decisions

Investigating the loading behaviour of intact and meniscectomy knee joints and the impact on surgical decisions Investigating the loading behaviour of intact and meniscectomy knee joints and the impact on surgical decisions M. S. Yeoman 1 1. Continuum Blue Limited, One Caspian Point, Caspian Way, CF10 4DQ, United

More information

Analysis of Plate Bone Construct Failure Following Tibial Tuberosity Advancment

Analysis of Plate Bone Construct Failure Following Tibial Tuberosity Advancment Analysis of Plate Bone Construct Failure Following Tibial Tuberosity Advancment W. T. McCartney 1,2 E. Galvin 2 B Mac Donald D Comiskey 3 1 Marie Louise Veterinary Hospital, Baldoyle, Dublin 13, Ireland

More information

Comparison of volume estimation methods for pancreatic islet cells

Comparison of volume estimation methods for pancreatic islet cells Comparison of volume estimation methods for pancreatic islet cells Jiří Dvořák a,b, Jan Švihlíkb,c, David Habart d, and Jan Kybic b a Department of Probability and Mathematical Statistics, Faculty of Mathematics

More information

Bone Densitometry Radiation dose: what you need to know

Bone Densitometry Radiation dose: what you need to know Bone Densitometry Radiation dose: what you need to know John Damilakis, PhD Associate Professor and Chairman University of Crete, Iraklion, Crete, GREECE Estimation of bone status using X-rays Assessment

More information

This is a repository copy of Microarchitecture of bone predicts fractures in older women.

This is a repository copy of Microarchitecture of bone predicts fractures in older women. This is a repository copy of Microarchitecture of bone predicts fractures in older women. White Rose Research Online URL for this paper: http://eprints.whiterose.ac.uk/130351/ Version: Accepted Version

More information

Incorporating uncertainty in mechanical properties for finite element-based evaluation of bone mechanics

Incorporating uncertainty in mechanical properties for finite element-based evaluation of bone mechanics Journal of Biomechanics 40 (2007) 2831 2836 www.elsevier.com/locate/jbiomech www.jbiomech.com Incorporating uncertainty in mechanical properties for finite element-based evaluation of bone mechanics Peter

More information

Disclosures. Beyond BMD: Bone Quality & Bone Strength. Design of a Structure. Fractures = structural failure of the skeleton

Disclosures. Beyond BMD: Bone Quality & Bone Strength. Design of a Structure. Fractures = structural failure of the skeleton Disclosures Beyond BMD: Bone Quality & Bone Strength Mary L. Bouxsein, PhD Center for Advanced Orthopedic Studies, BIDMC Department of Orthopedic Surgery, HMS MIT-Harvard Health Sciences and Technology

More information

Collars on Cementless Femoral Stems Make More of a Contribution to Primary Stability When Subjected to Adverse Mechanical Environments

Collars on Cementless Femoral Stems Make More of a Contribution to Primary Stability When Subjected to Adverse Mechanical Environments Collars on Cementless Femoral Stems Make More of a Contribution to Primary Stability When Subjected to Adverse Mechanical Environments Mark Taylor, PhD 1, Scott Brumby, MD 2, David Beverland, MD 3, Clare

More information

Available online at ScienceDirect

Available online at   ScienceDirect Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 69 ( 2014 ) 1251 1257 24th DAAAM International Symposium on Intelligent Manufacturing and Automation, 2013 Comparative Study

More information

Experimental and Numerical Comparison of Stresses Level between Titanium and Novel Composite Single Tooth Implant

Experimental and Numerical Comparison of Stresses Level between Titanium and Novel Composite Single Tooth Implant International Journal of Mechanical & Mechatronics Engineering IJMME-IJENS Vol:15 No:06 84 Experimental and Numerical Comparison of Stresses Level between Titanium and Novel Composite Single Tooth Implant

More information

Effect of different load conditions on a DHS implanted human femur

Effect of different load conditions on a DHS implanted human femur Effect of different load conditions on a DHS implanted human femur Nooshin S. Taheri, Aaron S. Blicblau, and Manmohan Singh Abstract As a result of improving life expectancy, the number of elderly people

More information

Microstructural changes in the bone tissue and in the bone callus of diabetic rats with and without insulin treatment

Microstructural changes in the bone tissue and in the bone callus of diabetic rats with and without insulin treatment Microstructural changes in the bone tissue and in the bone callus of diabetic rats with and without insulin treatment A. Zamarioli 1, M.S. Campos 1, A. Guimarães 1, M. Butezloff 1, G.B. Leoni 2, M.D. Sousa-Neto

More information

Patient specific optimization of fracture treatment considering the inhomogeneous material properties of bone tissue and the expected load situation

Patient specific optimization of fracture treatment considering the inhomogeneous material properties of bone tissue and the expected load situation Lectures Patient specific optimization of fracture treatment considering the inhomogeneous material properties of bone tissue and the expected load situation M. Schimmelpfenning presented at the Weimar

More information

REGIONAL MECHANICAL PROPERTIES OF AAA TISSUE AND FINITE ELEMENT ANALYSIS OF RUPTURE

REGIONAL MECHANICAL PROPERTIES OF AAA TISSUE AND FINITE ELEMENT ANALYSIS OF RUPTURE USE OF REGIONAL MECHANICAL PROPERTIES OF ABDOMINAL AORTIC ANEURYSMS TO ADVANCE FINITE REGIONAL MECHANICAL PROPERTIES OF AAA ELEMENT MODELING OF RUPTURE RISK TISSUE AND FINITE ELEMENT ANALYSIS OF RUPTURE

More information

Age changes in the human femoral neck and progression to failure. Functional Adaptation in the Femoral Neck

Age changes in the human femoral neck and progression to failure. Functional Adaptation in the Femoral Neck Age changes in the human femoral neck and progression to failure Functional Adaptation in the Femoral Neck Changes with Ageing Processes Associated with Structural Failure From the macroscopic to the microscopic

More information

Simulation of Ridge Formation in Cortical Bone near the Anterior Cruciate Ligament Insertion: Bone Remodeling due to Interstitial Fluid Flow

Simulation of Ridge Formation in Cortical Bone near the Anterior Cruciate Ligament Insertion: Bone Remodeling due to Interstitial Fluid Flow Simulation of Ridge Formation in Cortical Bone near the Anterior Cruciate Ligament Insertion: Bone Remodeling due to Interstitial Fluid Flow Yusuke TAKAHASHI, Shigehiro HASHIMOTO Biomedical Engineering

More information

Imaging to Assess Bone Strength and its Determinants

Imaging to Assess Bone Strength and its Determinants Imaging to Assess Bone Strength and its Determinants Mary L. Bouxsein, PhD Harvard Medical School, Boston, MA UCSF Osteoporosis Course 26 July 212 Consultant / advisor: Amgen, Eli Lilly, Merck Research

More information

Change in Femur Shape during Postnatal Development and Growth of C57BL/6 Mice

Change in Femur Shape during Postnatal Development and Growth of C57BL/6 Mice Change in Femur Shape during Postnatal Development and Growth of C57BL/6 Mice Introduction: Disorders of skeletal development, including hip dysplasia, slipped capital femoral epiphysis, and Legg-Calve-Perthes

More information

Thickness effects on maximum von-mises stress of a cement mantle in total hip replacement - a finite element study

Thickness effects on maximum von-mises stress of a cement mantle in total hip replacement - a finite element study Journal of Applied Biomaterials & Biomechanics 2009; Vol. 7 no. 2, pp. 111-115 Società Italiana Biomateriali Thickness effects on maximum von-mises stress of a cement mantle in total hip replacement -

More information

Use of Digital Image Correlation for Validation of Surface Strain in Specimen-specific Vertebral Finite Element Models

Use of Digital Image Correlation for Validation of Surface Strain in Specimen-specific Vertebral Finite Element Models Use of Digital Image Correlation for Validation of Surface Strain in Specimen-specific Vertebral Finite Element Models H. M. Gustafson 1,2 and P. A. Cripton 1,2 1 Orthopaedics and Injury Biomechanics Laboratory,

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 4,100 116,000 120M Open access books available International authors and editors Downloads Our

More information

The role of the calcar femorale in stress distribution in the proximal femuros4_

The role of the calcar femorale in stress distribution in the proximal femuros4_ Orthopaedic Surgery (2009), Volume 1, No. 4, 311 316 ORIGINAL ARTICLE The role of the calcar femorale in stress distribution in the proximal femuros4_53 311..316 Qi Zhang MD 1, Wei Chen MD 1, Huai-jun

More information

Validating FE predictions of distal radius failure load: standard region and 4% region

Validating FE predictions of distal radius failure load: standard region and 4% region Validating FE predictions of distal radius failure load: standard region and 4% region M Hosseinitabatabaei, N Soltan, M McDonald, C Kawalilak, G Johnston, S Kontulainen, JD Johnston Fixed Scan Position

More information

Finite Element Analysis of Dental Implant as Orthodontic Anchorage

Finite Element Analysis of Dental Implant as Orthodontic Anchorage JCDP 10.5005/jp-journals-10024-1044 ORIGINAL RESEARCH Finite Element Analysis of Dental Implant as Orthodontic Anchorage Finite Element Analysis of Dental Implant as Orthodontic Anchorage Anirban Sarmah,

More information

Femoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements

Femoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements Femoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements Daniel Kluess, Sarah Bierbaum, Wolfram Mittelmeier, Rainer Bader,

More information

Yener N. Yeni a,, Eric A. Zelman a, George W. Divine b, Do-Gyoon Kim a, David P. Fyhrie c. Introduction

Yener N. Yeni a,, Eric A. Zelman a, George W. Divine b, Do-Gyoon Kim a, David P. Fyhrie c. Introduction Bone 42 (2008) 591 596 www.elsevier.com/locate/bone Trabecular shear stress amplification and variability in human vertebral cancellous bone: Relationship with age, gender, spine level and trabecular architecture

More information

[ICESTM-2018] ISSN Impact Factor

[ICESTM-2018] ISSN Impact Factor GLOBAL JOURNAL OF ENGINEERING SCIENCE AND RESEARCHES MODELING AND FINITE ELEMENT ANALYSIS OF KNEE JOINT PROSTHESIS U.D.S.Prathap varma *1,S.Rajesh 2, B.Suresh Kumar 3 & P.Rama Murthy Raju 4 *1 M.TechScholar,

More information

Biomechanical Analysis of Jaw Bone with Cyst Using CT-Image Based Finite Element Method

Biomechanical Analysis of Jaw Bone with Cyst Using CT-Image Based Finite Element Method Research Article Biomechanical Analysis of Jaw Bone with Cyst Using CT-Image Based Finite Element Method Takaaki Arahira 1, Mitsugu Todo 2* 1 Department of Dental Engineering, Fukuoka Dental College 2-15-1

More information

Plate and Bone Stresses for Single- and Double-Plated Femoral Fractures. D.R. Carter and R. Vasu

Plate and Bone Stresses for Single- and Double-Plated Femoral Fractures. D.R. Carter and R. Vasu Plate and Bone Stresses for Single- and Double-Plated Femoral Fractures D.R. Carter and R. Vasu J. Biomech 14: 55-62, 1981 Loading Koch Conditions Intact Trans-cortical stress Composite Beam Representation

More information

Numerical predicting of contact and pressure sore of lower extremity parts caused by prosthetic and orthotic

Numerical predicting of contact and pressure sore of lower extremity parts caused by prosthetic and orthotic MACROJOURNALS The Journal of MacroTrends in Health and Medicine Numerical predicting of contact and pressure sore of lower extremity parts caused by prosthetic and orthotic Reza Fakhrai, Bahram Saadatfar,

More information

Peripheral Quantitative CT (pqct) Using a Dedicated Extremity Cone-Beam CT Scanner

Peripheral Quantitative CT (pqct) Using a Dedicated Extremity Cone-Beam CT Scanner SPIE Medical Imaging 23 Peripheral Quantitative CT (pqct) Using a Dedicated Extremity Cone-Beam CT Scanner A. A. Muhit, a S. Arora, a M. Ogawa, a Y. Ding, a W. Zbijewski, a J. W. Stayman, a G. Thawait,

More information

FINITE ELEMENT ANALYSIS : AN EFFECTIVE TOOL FOR PROSTHESES DESIGN

FINITE ELEMENT ANALYSIS : AN EFFECTIVE TOOL FOR PROSTHESES DESIGN Trends Biomater. Artif. Organs. Vol. 17(2) pp 141-148 (2004) http//www.sbaoi.org FINITE ELEMENT ANALYSIS : AN EFFECTIVE TOOL FOR PROSTHESES DESIGN S K Senapati & S.Pal School of Biosc, & Engg, Jadavpur

More information

Comparative study of mechanical stresses in human limb bones

Comparative study of mechanical stresses in human limb bones ORIGINAL RESEARCH Comparative study of mechanical stresses in human limb bones Doina Dra gulescu, 1 Lucian Rusu, 1 Vlad Morcovescu, 1 Cris Precup 2 1 Politehnica University of Timişoara, Timişoara, Romania;

More information

Beyond BMD: Bone Quality and Bone Strength

Beyond BMD: Bone Quality and Bone Strength Beyond BMD: Bone Quality and Bone Strength Consultant / advisor: Amgen, Eli Lilly, Merck Disclosures Mary L. Bouxsein, PhD Beth Israel Deaconess Medical Center Harvard Medical School, Boston, MA mbouxsei@bidmc.harvard.edu

More information

Failure criteria for Adhesives. Sainath Kadam, 3mE 19 oktober 2014

Failure criteria for Adhesives. Sainath Kadam, 3mE 19 oktober 2014 Failure criteria for Adhesives Sainath Kadam, 3mE 19 oktober 2014 () Failure criteria for Adhesives 1 / 59 Outline 1 Introduction 2 Testing 3 Data analysis 4 FEM 5 Results and Conclusions () Failure criteria

More information

Comparison of in Vitro Young and Old Lumbar Vertebrae of Ewes Related to Bone Density and Compression Strength

Comparison of in Vitro Young and Old Lumbar Vertebrae of Ewes Related to Bone Density and Compression Strength Modern Applied Science; Vol. 11, No. 4; 2017 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education Comparison of in Vitro Young and Old Lumbar Vertebrae of Ewes Related

More information

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia Types of Plates 1. New Dynamic Compression Plate: DCP Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia 1. Undercut adjacent to the holes low contact: less stress shield 2. Undercut at the undersurface

More information

Multi-scale Finite Element Analysis on Biomechanical Response of Functionally Graded Dental Implant / Mandible System

Multi-scale Finite Element Analysis on Biomechanical Response of Functionally Graded Dental Implant / Mandible System Journal of the Serbian Society for Computational Mechanics / Vol. 1 / No. 1, 2007 / pp. 164-173 Multi-scale Finite Element Analysis on Biomechanical Response of Functionally Graded Dental Implant / Mandible

More information

Modeling of human knee joint and finite element analysis of landing impact motion

Modeling of human knee joint and finite element analysis of landing impact motion ISSN 1746-7659, England, UK Journal of Information and Computing Science Vol. 13, No. 1, 2018, pp.044-048 Modeling of human knee joint and finite element analysis of landing impact motion Bao Chunyu 1,3,Meng

More information

Preclinical biomechanics of a new intramedullary nail for femoral diaphyseal fractures

Preclinical biomechanics of a new intramedullary nail for femoral diaphyseal fractures ISSN 2304-3415, Russian Open Medical Journal 1 of 7 Original article Preclinical biomechanics of a new intramedullary nail for femoral diaphyseal fractures Dmitry Ivanov 1, Anatoly Barabash 2, Yuri Barabash

More information

Bone density and shape adapt to loading. Bone remodeling simulation models. Bone remodeling. But... Frost: mechanostat theory. Bone remodeling theory

Bone density and shape adapt to loading. Bone remodeling simulation models. Bone remodeling. But... Frost: mechanostat theory. Bone remodeling theory Bone density and shape adapt to loading Bone remodeling simulation models Turkey Ulna experiments (Rubin et al) Sheep ulnar osteotomy (McNamara) Bert van Rietbergen Bone is deposited in regions of high

More information