Chin J Radiol 2002; 27:
|
|
- Curtis Sharp
- 6 years ago
- Views:
Transcription
1 Chin J Radiol 2002; 27: the Digital Imaging and Communications in Medicine, DICOM [1] DICOM the American College of Radiology and the National Electrical Manufactures Association (ACR-NEMA) [2,3] DICOM Picture Archiving and Communication System, [4,5] Digital Radiography, DR Computed Radiography, CR Image Plate, IP 222 Quality Assurance, QA Digital Imaging System RIS HIS Electronic Patient/Medical Record System, EPR or EMR
2 298 MRI in cobalamin deficiency [6] FCR accession number X [7] 5
3 MRI in cobalamin deficiency International Business Machines Corpaoation, RISC System/6000-SP2, White Plains, New York, USA AIX, version 4.3.1, New York, USA, Oracle 8.0, Redwood Shores, CA, USA HIS Sun Microsystems, Inc. Ultra Eterprise 450, Santa Clara, CA, USA Image Storage Unit, ISU Modality Interface Unit, MIU Apple, Mac G4, Cupertino, CA, USA imaging modalities DICOM 3:1 lossless GE PathSpeed CT Head and Neck CT Body Extremity MRI Head and Neck MRI Body Extremity Body Extremity CT Body Extremity, MRI Body Extremity, and Body Extremity F7
4 300 MRI in cobalamin deficiency picture archiving and communication system, ISU (image storage unit); ARC (archive); MIU (modality interface unit); HL7 (Health level 7); HIS (hospital information system); RIS (radiology information system) Redundant Array of Inexpensive Disks, RAID5 RJ MB 7 LEO, Pentium III 300MHz ~ Pentium IV 1GHz, Taiwan, ROC Microsoft, Windows 98/ NT/2000, Taiwan, ROC (1) (2) / 8 (3) GE PathSpeed eb browser (4) (5) QA GE, PathSpeed Exam Manager 8.1, Milwaukee, Wisconsin, USA GE, Medical Systems, Taiwan, ROC Fuji, QA/WS771, Minato-ku, Tokyo, Japan DELL Computer corporation, Precision 420, Round Rock, Texas, USA (6) BARCO, MGD521 ( )/MGD 221( ), Kortrijk, Belgium (7) ViewSonic, 17 SVGA monitor, Walnut, CA, USA (8) EPSON, LQ-670C, Nagano, Japan Tally, T2145, Kent, WA, USA (9) Bar-code reader REGAL, IM-7100 ED, New York, USA (1) GE, Advantage HiSpeed CT, Milwaukees, Wisconsin, USA SIEMENS, SOMATOM Emotion CT, Müenchen, Germany (2) Philips, Gyroscan T5-NT, Best, Holland (3) Philips, Integris V3000, Best, Holland (4) Philips, Diagnost 96, Best, Holland (5) Fuji, FCR 5000, Tokyo, Japan Fuji IDT Gateway Fuji ID terminal (6) Image plate, IP (7) Fuji, QA/WS771, Tokyo, Japan DICOM 3.0 CCD 39 9 (1) start code (2) (data code (3) check code (4) end code 39 Code 39 /
5 MRI in cobalamin deficiency LCD (%) Fuji ID Terminal RS232 USB Fuji ID Terminal / CPU Default AUTO CR QA/WS771 DICOM 3 11 YY MM DD L SSSS 12 YY M D L SSSS ) X SS 1 C 10 A 10 B 11 C 12 1 X I,O 1 0 / 10 T Fuji IDT Gateway 11 Fuji ID Terminal 12 Fuji ID
6 302 MRI in cobalamin deficiency Terminal ID Terminal ID Terminal IP IP 56 0% 222 Fuji FCR5000 QA/WS % 2 DICOM (1) 1998 CR F7 GE PathSpeed (2) X CT 7 17:00-21:00 60~ [7] 1,648 15% 222 (1) (2) 56 LED 1 (3) EPSON LQ-650C TALLY T2145 REGAL IM- 7100ED (1) (2) TALLY T2145 EPSON LQ-650C (3) Fuji ID Terminal 7.5 (4) LCD % Fuji REGAL IM-7100ED
7 MRI in cobalamin deficiency Terminal FCR ID CR Terminal 400 DR ID X /11/06 SIMENS SOMATOM EMOTION CT work-list 10 GE Advantage HiSpeed Philips Gyroscan T5-NT Patient Register 1. Hindel R. Ed. Implementation of the DICOM 3.0 standard: a pragmatic handbook. Oak Brook, IL: Radiologyical Society of North America, RSNA Lou SL, David R. Hoogstrate and H.K. Huang, An Automate Image Acquisition and Recovery Scheme for Image Integrity Based on the DICOM Standard, Comput Med Imaging Graphics 1997; 21: Moore SM. Observation on DICOM demonstration at the RSNA annual meetings. Proc. SPIE, Med Imag 1996; 2711: Lou SL, Wang J, Moskowitz M, Bazzill T, Huang HK. Methods of automatically acquiring images from digital medical systems. Comput Med Imaging Graphics 1995; 19: Prior FW. Specifying DICOM compliance for modality interface. Radiographics 1993; 13: Huang HK. Introduction, basic principles and applications, Canada, Wiley-Liss Inc., 1999: Chen CN, Lee SK, Hung SW, Huang SK, Chun JS, Hwang CJ. The Application of the Barcode in the Radiology Department. Chin J Radiol 2000; 25:
8 304 MRI in cobalamin deficiency The Application of Bar-Code in Picture Archiving and Communication System CHIH-MING FAN 1,2 CHUN-HSU YAO 2 JACKSON C-T LIN 2 GWO-HAO HO 4 HSUN-SHENG HUNG 4 SHU-HANG NG 1 Department of Radiology 1 and Department of Medical Information Administration 4, Chang Gung Memorial Hospital Department of radiological Technology 2, Chung-Tai Institute of Health Sciences and Technology Department of Medical Imaging 3, Chung Shan Medical University Hospital Bar-code system is widely utilized in our daily life. In order to assess the usefulness of the bar-code system in picture archiving and communicating system (), we used bar-code reader as the complementary tool of for registration, radiographic taking, and imaging reporting in the department of the diagnostic radiology. Our hospital has just accomplished with bar-code system for the Health Care Center, Intensive Care Unit and Emergency Department. The working flow of our computer radiography (CR) is currently more complicate than that of the conventional radiography. It requires registry, printing registry sheet, selecting the items of the procedure from the work-list and seting imaging parameter in the CR ID terminal, taking radiography, reading imaging by CR reader, imaging quality assurance, transporting images to the, printing images, and film interpretation. In this study, we used bar code in for the purposes to reduce the workload and the keyboard input error of technologists, and to facilitate radiologists to interpret the images on viewers by rapid retrieval of Hospital Information System (HIS) and the Radiology Information System (RIS). From an analysis of 102 randomized cases using key-broad to input examination information, we found that the averaged time for the routine radiologic procedures was 7 seconds, while for CT and MRI was 47 seconds. The error percentage is 2.95%. For comparison, we assessed the efficiency of bar code in retrieving medical information from 56 patients. We found that each data retrieval with bar code required only one second and the error percentage was zero. In addition, radiologists took the advantage of bar code by getting the images, clinical and radiological data simultaneously, obviating any input mistake. We concluded that bar code could enhance the efficiency of technologist and radiologist during executing. Key words: Bar-Code reader, Computer Radiography, Digital Radiography, Picture Archiving and Communication System, Work-list
Medical Diagnostic Imaging
Medical Diagnostic Imaging Laboratories Medical Diagnostic Imaging Lab Name Location Person in Charge Programs Served Courses Served Patient Care and Management (2) Introduction to MDI Radiographic Technique
More informationImpact of PACS on Dictation Turnaround Time and Productivity
Impact of PACS on Dictation Turnaround Time and Productivity Luigi Lepanto, M.D., 1 Guy Paré, Ph.D., 2 David Aubry, M.Sc., 2 Pierre Robillard, M.D., 1 and Jacques Lesage, M.D. 1 This study was conducted
More informationRadiologist Peer Review Program Implementation Improving Quality, Enabling Collaboration and Innovating Continuously
Radiologist Peer Review Program Implementation Improving Quality, Enabling Collaboration and Innovating Continuously Radiological Society of North America Annual Meeting 2017 1 Contents Background: The
More informationA real-time interactive pulmonary nodule analysis system
Clinical applications A real-time interactive pulmonary nodule analysis system E.J.R. van Beek B.F. Mullan B.H.Thomson Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City,
More informationDosimeter Setting Device
Instruction Manual Dosimeter Setting Device For Electronic Personal Dosimeter Dose-i (Unit:Sv, Version:1.05 English) WTA529748 a 1 / 38 Foreword Thank you for purchasing the Dosimeter Setting Device; a
More informationINTRODUCTION TO DICOM FOR THE PRACTICING VETERINARIAN
INTRODUCTION TO DICOM FOR THE PRACTICING VETERINARIAN MATTHEW A. WRIGHT, DENNIS BALLANCE, IAN D. ROBERTSON, BRIAN POTEET Digital Imaging and Communication in Medicine (DICOM) is a communication protocol
More informationIntroduction and Background
CT Lung Cancer Screening and the Medical Physicist: Background, Findings and Participant Dosimetry Summary of the National Lung Screening Trial (NLST) Randell Kruger, PhD, DABR Medical Physics Section
More informationDigital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care.
Digital Mammography Imaging on KODAK CR Systems Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care. Commercial distribution of the CR Mammography
More informationX-ray (Radiography) - Chest
Scan for mobile link. X-ray (Radiography) - Chest Chest x-ray uses a very small dose of ionizing radiation to produce pictures of the inside of the chest. It is used to evaluate the lungs, heart and chest
More informationEchocardiography A powerful module of MediConnect
Echocardiography A powerful module of MediConnect WHERE IT ALL COMES TOGETHER MEDICONNECT AN OVERVIEW Integrating the latest IT technologies with medical expertise within an existing clinical infrastructure
More informationA Web based Computer aided Diagnosis Tool for Bone Age Assessment:
Society of Pediatric Radiology 2009 A Web based Computer aided Diagnosis Tool for Bone Age Assessment: Clinical Implementation and Lessons Learned K Ma*; P Moin, MD*; M Fleshman*; L Vachon, MD**; A Zhang,
More informationInteraction techniques for radiology workstations: impact on users' productivity
Interaction techniques for radiology workstations: impact on users' productivity Abstract Moise, Adrian; Atkins, M. Stella {amoise, stella }@cs.sfu.ca Simon Fraser University, Department of Computing Science
More informationFor true visualisation
ENGLISH For true visualisation Planmeca ProModel is a patient-specific physical model for high-end maxillofacial operations and dental surgery. By reproducing the anatomy of the patient in real-size, Planmeca
More informationX-ray (Radiography) - Bone
Scan for mobile link. X-ray (Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones or
More informationFor Electric Personal Dosimete Dose-i
Instruction Manual Dosime eter Setting Device For Electric Personal Dosimete er Dose-i (Unit:rem, Version:1.05 English) Issued on March 2015 WTA529893 1 / 38 Foreword Thank you for purchasing the Dosimeter
More informationRS85 Ultrasound System DICOM Conformance Statement
RS85 Ultrasound System DICOM Conformance Statement Revision 1.0 System Version 1.0 Created: October 20, 2017 Last Updated: October 20, 2017 RS85 DICOM Conformance SAMSUNG MEDISON 0 COVER PAGE Company Name:
More informationHealth informatics Digital imaging and communication in medicine (DICOM) including workflow and data management
INTERNATIONAL STANDARD ISO 12052 Second edition 2017-08 Health informatics Digital imaging and communication in medicine (DICOM) including workflow and data management Informatique de santé Imagerie numérique
More informationVariation of Occupational Doses among Subspecialties in Diagnostic Radiology. A.N. Al-Haj, C.S. Lagarde, A.M. Lobriguito
Variation of Occupational Doses among Subspecialties in Diagnostic Radiology A.N. Al-Haj, C.S. Lagarde, A.M. Lobriguito Biomedical Physics Department, MBC 03 King Faisal Specialist Hospital and Research
More informationWhat Computer Tools to Use for Your Quality and Safety Program
What Computer Tools to Use for Your Quality and Safety Program Lincoln L. Berland, M.D., F.A.C.R. University of Alabama at Birmingham Disclosure Consultant to Nuance, Inc. Learning Objectives Understand
More informationCaptus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive
Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier. The Captus 3000 combines a software program with the
More informationDICOM Conformance Statement
DICOM Conformance Statement Document Version 2.0 Revision Summary Date Revision Changes 30 th December 2016 2.0 Update to OrthoView 7.0 Specification 20 October 2005 1.0 Release of OrthoView 3.1 WK3 build
More informationIntroducing the future of DXA. Powerful images. Clear answers. Horizon DXA System
Introducing the future of DXA Powerful images. Clear answers. Horizon DXA System Hologic turns ideas into innovation. Again. Hologic cares about you and your patients about keeping their bones healthy,
More information19 CP Add teaching file export related codes
19 CP-1680 - Add teaching file export related codes Page 1 1 Status Final Text 2 Date of Last Update 2017/09/14 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com 5 Submitter Name David Clunie
More informationBody Composition Analyzer
For Advanced Analysis Body Composition Analyzer 370S_catalog_Eng_A_161020.indd 1 2016. 10. 20. 오후 3:12 InBody Since InBody established in 1996, we have strived to operate as an excellent, 21st-century
More informationHEALTHCARE AI DEVELOPMENT CYCLE
Dr. Keith Dreyer Chief Science Officer, ACR Data Science Institute ACR Board of Chancellors, Chairman Informatics Commission Chief Data Science Officer, MGH, BWH, Partners Healthcare Associate Professor
More informationrience at Georgetown University
PACS clinical rience at Georgetown University Steven C, Horii, Seong Ki Mun, Larry P. Elliott, Betty Levine, Ben Lo, Brian S. Garra, Robert E:. &man, Matthew Freedman, Clifton Leftridge, Dieter Schellinger,
More informationMQSA Physicist Qualifications. Jon J. Erickson, Ph.D., DABR
2027 North 36 th Street Saint Joseph, Mo 64506 (86) 390-90 (800) 306-4477 MQSA Physicist Qualifications Jon J. Erickson, Ph.D., DABR Contents Missouri Mammography Physicist Initial Qualifications Certificate
More informationInformation Systems Integration in Radiology
Information Systems Integration in Radiology Janice C. Honeyman Advances in information systems and technology in conjunction with outside forces requiring improved reporting are driving sweeping changes
More informationSolutions at GE Inspection Technologies
Solutions at GE Inspection Technologies Business Overview Paul A. Meyer Our Company A global leader in technology-driven inspection solutions that deliver productivity, quality, and safety to our customers
More information19 CP Add teaching file export related codes
19 CP-1680 - Add teaching file export related codes Page 1 1 Status Letter Ballot 2 Date of Last Update 2017/06/21 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com 5 Submitter Name David Clunie
More informationImage Registration: The Challenge for QA Centers
Image Registration: The Challenge for QA Centers Kenneth Ulin, Ph.D. Marcia M. Urie, Ph.D. Quality Assurance Review Center Imaging Studies Used for: Staging Protocol Eligibility Target Volume Definition
More informationInnovative Lung Cancer Screening Solution
Innovative Lung Cancer Screening Solution Lung cancer is the leading cause of cancer deaths for both men and women, resulting in more than 150,000 deaths each year in the United State; a fi gure that is
More informationMR IMAGING OF THE LUMBAR SPINE A TEACHING ATLAS 1ST EDITION
page 1 / 5 page 2 / 5 mr imaging of the pdf MR Imaging of Parotid Tumors: Typical Lesion Characteristics in MR Imaging Improve Discrimination between Benign and Malignant Disease MR Imaging of Parotid
More informationInformatics in Radiology
Note: This copy is for your personal non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, contact us at www.rsna.org/rsnarights. INFORMATICS 655 Informatics
More informationProven clinical effectiveness at low radiation dose
MicroDose Mammography Solutions Proven clinical effectiveness at low radiation dose Several studies provide evidence that Philips MicroDose Mammography* can provide outstanding image quality at 18% to
More informationIntravenous Pyelogram (IVP)
Scan for mobile link. Intravenous Pyelogram (IVP) Intravenous pyelogram (IVP) is an x-ray exam that uses an injection of contrast material to evaluate your kidneys, ureters and bladder and help diagnose
More informationSession 2: The Role of Specialist Radiology Technologists
Session 2: The Role of Specialist Radiology Technologists Louise M. Henderson, MSPH PhD Assistant Professor, Department of Radiology The University of North Carolina, Chapel Hill Overview Role of the technologist
More informationQuantitative Measurement of Cardiac Biomarkers
Cardiac Biomarker Analyzer Quantitative Measurement of Cardiac Biomarkers Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Results in 17 minutes Direct measurement from whole blood samples 6 parallel
More information5/28/2015. The need for MRI in radiotherapy. Multiparametric MRI reflects a more complete picture of the tumor biology
Ke Sheng, Ph.D., DABR Professor of Radiation Oncology University of California, Los Angeles The need for MRI in radiotherapy T1 FSE CT Tumor and normal tissues in brain, breast, head and neck, liver, prostate,
More informationGEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7
GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7 NOTICE: This document is version controlled and was produced as a part of the GEX Information Program which requires that all Series 100
More informationEarly Detection of Lung Cancer
Early Detection of Lung Cancer Aswathy N Iyer Dept Of Electronics And Communication Engineering Lymie Jose Dept Of Electronics And Communication Engineering Anumol Thomas Dept Of Electronics And Communication
More informationANNUAL REPORT OF POST-PRIMARY EXAMINATIONS 2014
ANNUAL REPORT OF POST-PRIMARY EXAMINATIONS 214 INTRODUCTION The ARRT offers two categories of certification and registration: primary and post-primary. This report summarizes the results of the 214 post-primary
More informationVarian Treatment. Streamlined Treatment Delivery Management Application. Specifications
Varian Treatment Streamlined Treatment Delivery Management Application Specifications Specifications Varian Treatment 1 Introduction Streamlined Treatment Delivery Management Varian Treatment verifies
More informationPACS PACS . PACS. Published By Tehran University Of Medical Sciences
45.. PACS (PACS) 5 4 3 2 *1 1390/5/26 : 1390/2/14 : : (PACS) :.. PACS 88 :.. -. :.. :. 83/3 43/1 PACS. 66/7 80 PACS. PACS :. DICOM PACS : ( *) -1 E-mail: njabbarimp@gmail.com 0441-2752298 : -2-3 -4-5 ..39
More informationMulticenter Trial, Phase I Assessment of 2-D FFDM Versus Combo of 2-D and 3-D Tomosynthesis in Breast Cancer Screening
ACRIN PA 4006: Comparison of Full Field Digital Mammography with Digital Breast Tomosynthesis Image Acquisition in Relation to Screening Call-Back Rate Imaging Manual Multicenter Trial, Phase I Assessment
More informationStudy on User Interface of Pathology Picture Archiving and Communication System
Original Article Healthc Inform Res. 2014 January;20(1):45-51. pissn 2093-3681 eissn 2093-369X Study on User Interface of Pathology Picture Archiving and Communication System Dasueran Kim, MS 1, Peter
More informationDosimeter Setting Device System NRZ
User s Manual Dosimeter Setting Device System NRZ For Dosimeter NRF series (Units: msv Version:0.26 English) TA5C0903 b 1 / 50 Preface Thank you for purchasing the Dosimeter Setting Device; a product by
More informationThe Veterinarian s Choice. Delta Six.
The Veterinarian s Choice Delta Six www.esaote.com Compact & Complete Making the Difference! Mobile Patient ID/Owner Name The patient demographic screen is dedicated to the veterinary environment with
More informationBackground Information
Background Information Erlangen, November 26, 2017 RSNA 2017 in Chicago: South Building, Hall A, Booth 1937 Artificial intelligence: Transforming data into knowledge for better care Inspired by neural
More informationUCLA UCLA UCLA 7/10/2015. The need for MRI in radiotherapy. Multiparametric MRI reflects a more complete picture of the tumor biology
Ke Sheng, Ph.D., DABR Professor of Radiation Oncology University of California, Los Angeles The need for MRI in radiotherapy T1 FSE CT Tumor and normal tissues in brain, breast, head and neck, liver, prostate,
More informationTrends in examination frequency and population doses in Norway,
Workshop on European Populaltion Doses from Medical Exposure, 24-26 April 2012, Athens, Greece Trends in examination frequency and population doses in Norway, 2002-2008 OLERUD H.M. 1,2, FRIBERG E.G. 1,
More informationvertaplan the spine surgeon s software vertaplan System for successful reconstruction of the individual sagittal balance
the spine surgeon s software System for successful reconstruction of the individual sagittal balance What do you think of patient-specific reconstruction of the spine geometry? Optimum surgical outcome
More informationUGEO HM70A Ultrasound System DICOM Conformance Statement
UGEO HM70A Ultrasound System DICOM Conformance Statement Revision 1.0 System Version 1.0 Created: Dec 06, 2013 Last Updated: Dec 06, 2013 UGEO HM70A DICOM Conformance SAMSUNG MEDISON 0 COVER PAGE Company
More informationCatalog Addendum
Catalog Addendum - 2018 Day Class RADIOLOGIC TECHNOLOGY (Levittown) HEGIS CODE: 5207.00 Radiologic Technologies (X-Ray) Day Program - 2005 Hours (16 mos./67 wks.) Diploma Program Hunter Business School
More informationCosts of plain-film radiography in a partially digitized radiology department
Acta Radiologica ISSN: 04-151 (Print) 1600-0455 (Online) Journal homepage: https://www.tandfonline.com/loi/iard0 Costs of plain-film radiography in a partially digitized radiology department J. Alanen,
More informationThe Key to Confidence
WITH The Key to Confidence The Key to Confidence More detail, better accuracy, greater confidence The G-scan Brio is a revolutionary MRI approach for all musculoskeletal applications, which allows you
More informationAmendment No. 2. Item No. 2 (Rfx/ Event number )
Amendment 2 Sub: Amendment to the Document 06.12.2018 Ref.: Notice Inviting Bid ref. HITES/PCD/NCI-AIIMS/36/18-19 dated 26.09.2018 read with its Amendment no. 1 dated 19.11.18 The following changes have
More informationAdvanced Point-of-Care Bone Health Assessment HOLOGIC OSTEOPOROSIS ASSESSMENT
O S T E O P O R O S I S A S S E S S M E N T Advanced Point-of-Care Bone Health Assessment HOLOGIC OSTEOPOROSIS ASSESSMENT Identify Patients at Risk The evaluation of bone health has become an essential
More informationDICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL TUS-AI900 V1.5 MODEL TUS-AI800 V1.5 MODEL TUS-AI700 V1.5
DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL TUS-AI900 V1.5 MODEL TUS-AI800 V1.5 MODEL TUS-AI700 V1.5 TOSHIBA MEDICAL SYSTEMS CORPORATION 2016 ALL RIGHTS RESERVED Trademarks Aplio
More informationASJ. Magnification Error in Digital Radiographs of the Cervical Spine Against Magnetic Resonance Imaging Measurements. Asian Spine Journal
Asian Spine Journal Asian Spine Clinical Journal Study Asian Spine J 2013;7(4):267-272 Magnification http://dx.doi.org/10.4184/asj.2013.7.4.267 error in cervical spine 267 Magnification Error in Digital
More informationMR QA/QC for MRgRT. Rick Layman, PhD, DABR Department of Radiology July 13, 2015
MR QA/QC for MRgRT Rick Layman, PhD, DABR Department of Radiology July 13, 2015 The Ohio State University Comprehensive Cancer Center Arthur G. James Cancer Hospital and Richard J. Solove Research Institute
More informationQuantitative Measurement of Emergency Biomarkers in Parallel
Point-of-Care Immunoassay Analyzer Quantitative Measurement of Emergency Biomarkers in Parallel Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Results in 17 minutes Direct measurement from whole
More informationMammography. What is Mammography? What are some common uses of the procedure?
Mammography What is Mammography? Mammography is a specific type of imaging that uses a low-dose x-ray system to examine breasts. A mammography exam, called a mammogram, is used to aid in the early detection
More informationRADIOLOGY VERSION 5. Retrospective data in full ACIR
RADIOLOGY VERSION 5 Retrospective data in full ACIR 2008-2015 Contents Radiology, version 5 1 Report availability... 1 1.1 Emergency department / critical care unit plain radiography reports (L) 1 1.2
More informationTHYROID UPTAKE SYSTEMS
76 CAPTUS 4000e THYROID UPTAKE SYSTEM New and improved stand provides ergonomically adjustable monitor and easy to position articulating collimator arm. Four sided comfortable handle grips and swivel wheels
More informationScintimammography. What is scintimammography?
Scan for mobile link. Scintimammography Scintimammography uses small amounts of radioactive materials called radiotracers, a special camera and a computer to help investigate an abnormality discovered
More informationDigital Imaging and Communications in Medicine (DICOM) Supplement 45: Ultrasound Protocol Supplement
ASE ACR NEMA Digital Imaging and Communications in Medicine (DICOM) Supplement 45: Ultrasound Protocol Supplement Prepared by: DICOM Standards Committee, Working Group 12 Ultrasound 1300 N. 17 th Street
More informationWelch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.
Welch Allyn ABPM 6100S Comprehensive blood pressure monitoring that brings patient comfort home. Features and Benefits of the Welch Allyn ABPM 6100S Pictorial application instructions, artery markers and
More informationPre-treatment verification for IMRT / IGRT and Rotational therapy
In OmniPro-I mrt Vivo treatment software verification Pre-treatment verification for IMRT / IGRT and Rotational therapy Introduction Introduction Introduction Introtro Intro Intro The rapid development
More informationRadiological Technology (Radiography): Emergence of a Profession
Radiological Technology (Radiography): Emergence of a Profession (Dr) Bev Snaith Consultant Radiographer, Mid Yorkshire Hospitals Honorary Research Fellow, University of Bradford UK Introduction Gratitude
More informationInteroperability Matters: Impact on Mammography Outcomes Session # 314, February 23, 2017
Interoperability Matters: Impact on Mammography Outcomes Session # 314, February 23, 2017 Wyatt M.Tellis, PhD, Director of Imaging IT Solutions Kathryn Pearson, MD, Breast Imaging Radiologist & Consultant.
More informationRS80A Ultrasound System DICOM Conformance Statement
RS80A Ultrasound System DICOM Conformance Statement Revision 1.1 System Version 1.00.03 Created: June 02, 2014 Last Updated: August 22, 2014 RS80A DICOM Conformance SAMSUNG MEDISON 0 COVER PAGE Company
More informationMammography. What is Mammography?
Scan for mobile link. Mammography Mammography is a specific type of breast imaging that uses low-dose x-rays to detect cancer early before women experience symptoms when it is most treatable. Tell your
More informationElectronic collimation and radiation protection in paediatric digital radiography: revival of the silver lining
Insights Imaging (2013) 4:723 727 DOI 10.1007/s13244-013-0281-5 PICTORIAL REVIEW Electronic collimation and radiation protection in paediatric digital radiography: revival of the silver lining J. Bomer
More informationCT Imaging at the Point-of-Care
ENGLISH True Dedication The new Planmed Verity Extremity CT Scanner revolutionizes extremity CT imaging. The compact unit brings 3D imaging at emergency departments, orthopedic clinics or trauma centers
More informationObserver variation for radiography, computed tomography, and magnetic resonance imaging of occult hip fractures
Observer variation for radiography, computed tomography, and magnetic resonance imaging of occult hip fractures Collin, David; Dunker, Dennis; Gothlin, Jan H.; Geijer, Mats Published in: Acta Radiologica
More informationThe New Frontier in Hip Preservation Preoperative CT-based Planning for FAI correction
The New Frontier in Hip Preservation Preoperative CT-based Planning for FAI correction DYONICS PLAN Hip Impingement Planning System DYONICS PLAN will substantially raise the bar on the standard of what
More informationDual-energy Vertebral Assessment
Dual-energy Vertebral Assessment gehealthcare.com Dual-energy Vertebral Assessment More than 40% of women with normal or osteopenic BMD had a moderate or severe vertebral deformation seen with DVA. Patrick
More informationEvaluation of Real-time Outbreak and Disease Surveillance (RODS) system in Taiwan
Evaluation of Real-time Outbreak and Disease Surveillance (RODS) system in Taiwan Yi-Chen Tsai EIC / FETP Taiwan CDC October 25, 2014 Real-time Outbreak and Disease Surveillance (RODS) system An automated
More informationBreast Tomosynthesis. What is breast tomosynthesis?
Scan for mobile link. Breast Tomosynthesis Breast tomosynthesis is an advanced form of mammography, a specific type of breast imaging that uses low-dose x-rays to detect cancer early when it is most treatable.
More informationPreparing for Medical Physics Components of the ABR Core Examination
Preparing for Medical Physics Components of the ABR Core Examination The ABR core examination for radiologists contains material on medical physics. This content is based on the medical physics that is
More informationA VIRTUAL TRAINING SYSTEM FOR CHEST RADIOGRAM INTERPRETATIONS USING ANATOMICAL HUMAN STRUCTURES IN HIGH-RESOLUTION CT IMAGES
A VIRTUAL TRAINING SYSTEM FOR CHEST RADIOGRAM INTERPRETATIONS USING ANATOMICAL HUMAN STRUCTURES IN HIGH-RESOLUTION CT IMAGES T. Hara*, X. Zhou*, H. Fujita*, I. Kurimoto*, T. Kiryu**, R. Yokoyama**, H.
More informationLymphoma is a cancer that develops in the white blood cells (lymphocytes) of the lymphatic system, which is part of the body's immune system.
Scan for mobile link. Lymphoma Lymphoma is a cancer that develops in the white blood cells of the lymphatic system. Symptoms may include enlarged lymph nodes, unexplained weight loss, fatigue, night sweats
More informationX X X. GXS-700 Direct USB Digital Intraoral Sensors. Buy a Sensor Combo and a Digital Pan Unit, Receive $600 Off! GO.BENCO benco.
8 0 0. G O. B E N C O b e n c o. c o m GS-700 Direct USB Digital Intraoral Sensors Designed to make migrating from film, or upgrading an existing digital system, easier than ever High quality image capture
More informationAvaya IP Office R9.1 Avaya one-x Portal Call Assistant Voluntary Product Accessibility Template (VPAT)
Avaya IP Office R9.1 Avaya one-x Portal Call Assistant Voluntary Product Accessibility Template (VPAT) Avaya IP Office Avaya one-x Portal Call Assistant is an application residing on the user s PC that
More informationEmergency Care Clinical Data Transmission Networks
Emergency Care Clinical Data Transmission Networks Preparing for Patient Arrival and Care Application Note Send Consult Prepare The Goal: Better Information, More Informed Decisions From the moment ALS
More informationClinical Trial Credentialing:
IROC Mission Clinical Trial Credentialing: Provide integrated radiation oncology and diagnostic Where imaging to Start quality and control programs in support of the NCI s NCTN Network thereby Resources
More informationUpdate of Digital Breast Tomosynthesis. Susan Orel Roth, MD
Update of Digital Breast Tomosynthesis Susan Orel Roth, MD NCI estimates that : Why DBT? Approximately 20% of breast cancers are missed at mammography screening Average recall rates approximately 10%
More informationSimple is better. MAC 2000 ECG analysis system
Simple is better Simple is Productive Simple is Connected Simple is Reliable Product overview MAC 2000 ECG analysis system Simple is productive Simple is Productive Simple is Connected Simple is Reliable
More informationNew Information Object Definitions for DICONDE
4th European-American Workshop on Reliability of NDE - Th.5.B.4 New Information Object Definitions for DICONDE M. JOBST, GE Sensing & Inspection Technologies, Hürth, Germany; J. HANSEN, GE Sensing & Inspection
More information9/3/2015. New Mammographic Modality Training. Mammographer. Qualified Radiologic Technologist. Tomosynthesis Training
FDA Required Breast Tomosynthesis Training New Mammographic Modality Training On any new mammography technology, such as breast tomosynthesis, the Mammography Quality Standards Act (MQSA) (http:fda.gov/radiation-emitting
More informationHong Kong Association of Medical Physics. Guide to Candidates
Hong Kong Association of Medical Physics Certification of Medical Physicists Professional Assessment Guide to Candidates PA App Form (r2017.1) Contents Chapter 1 p. 3 Professional Assessment System and
More informationECG MACHINE KEC- Series
KIZLON ECG MACHINE KEC- Series 404 Crescent Royale, Off New Link Road Andheri West, Mumbai 40053, Phones: 022-6708747 Email: info@kizlon.com Website: www.kizlon.com ECG Machine KEC-A100 This ECG machine
More informationPulmonary nodule detection in PET/CT images: Improved approach using combined nodule detection and hybrid FP reduction
Pulmonary nodule detection in PET/CT images: Improved approach using combined nodule detection and hybrid FP reduction Atsushi Teramoto* a, Hiroshi Fujita b, Yoya Tomita c, Katsuaki Takahashi c, Osamu
More information8/1/2017. Financial Disclosures. Dose Tracking at MGH. How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center
How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center Mannudeep K. Kalra, MD Webster Center for Quality and Safety Massachusetts General Hospital Harvard Medical School
More informationDICOM Conformance Statement for. Hitachi ARIETTA Precision
DICOM Conformance Statement for Hitachi ARIETTA Precision Company Name : Hitachi, Ltd. Product Name : Diagnostic Ultrasound System Hitachi ARIETTA Precision Version : Version 1. 1 Date : 2016. 04. 01 Internal
More informationFeatures and Benefits
Features and Benefits DC7 Significant Features HIPAA Compliant Frequency Compound Imaging Standard i-clear Standard i-beam Standard SCI Digital Processing Channels 2048 Dynamic Range > 160 Db 10 Bit A/D
More informationXT series. Continuous Positive Airway Pressure
XT series Continuous Positive Airway Pressure XT series is one of the smallest CPAP in the market. Its palmsized and light weight design lends itself well to travel. However, it delivers the same effective
More informationCPU MF Formulas and Updates
CPU MF Formulas and Updates December 2017 John Burg z/os SMF 113 Record SMF113_2_CTRVN2 1 = z10 2 = z196 / z114 3 = zec12 / zbc12 4 = z13 / z13s 5 z14 2 2 RNI-based LSPR Workload Decision Table MP RNI
More information