Goniometric Reliability in a Clinical Setting

Size: px
Start display at page:

Download "Goniometric Reliability in a Clinical Setting"

Transcription

1 Goniometric Reliability in a Clinical Setting Elbow and Knee Measurements JULES M. ROTHSTEIN, PETER J. MILLER, and RICHARD F. ROETTGER Reliability of goniometric measurements has been examined only under standardized conditions and usually with healthy subjects. The purpose of this study was to assess goniometric reliability in a clinical setting. The reliability of goniometric measurements of passive elbow and knee positions was assessed using patients as subjects. The effect of using the means of repeated measurements and the interdevice reliability of three common goniometers were also examined. Results showed that intratester reliability for flexion and extension of the knee and the elbow joints was high (r = to ). Intertester reliability was also high (r =.88 to ) for these measurements except for measurements of knee extension (r = to.70). Although previous investigators have suggested that using the means of multiple measurements improves reliability, our data indicate that this procedure never improves the correlation coefficient more than.12. The reliability was similar for all three devices. The results of this study indicate that for the knee and elbow joints, goniometric measurements performed in a clinical setting can be highly reliable. The method described in this study provides a simple protocol that can be used clinically to investigate goniometric reliability. Key Words: Elbow joint, Goniometric measurement, Knee joint, Physical therapy. Although goniometry is a primary measurement tool in physical therapy for initial assessment and for charting patient progress, the reliability of using goniometry in a clinical setting has not been examined. In a clinical setting, measurement technique will often vary between therapists, partially because of their training and preferences and partially because of adaptations, such as positioning, which are necessary with different patients. Therefore, reliability studies that have used standardized protocols, limited numbers of therapists, and healthy subjects do not necessarily reflect the reliability of clinical goniometry. Dr. Rothstein is Instructor, Program in Physical Therapy, Washington University School of Medicine, St. Louis, MO (USA). He is also a consultant physical therapist at the Irene Walter Johnson Institute for Rehabilitation, Washington University Medical Center, St. Louis, MO Mr. Miller is Staff Physical Therapist, Professional Physical Therapy, Inc, Creve Coeur, MO and Research Assistant, Program in Physical Therapy. At the time of this study, he was Staff Physical Therapist, Jewish Hospital of St. Louis, Washington University Medical Center. Mr. Roettger is Instructor, Program in Physical Therapy, Washington University School of Medicine and Director of Physical Therapy, Jewish Hospital of St. Louis. This article was submitted October 13, 1982; was with the authors for revision eight weeks; and was accepted April 29, Previous reports on goniometric reliability have been made by Hellebrandt and associates, Boone et al, and Low. 13 Boone et al and Low each examined the reliability of goniometry when it was applied to healthy subjects. 2, 3 In the study by Boone et al, the therapists used a prescribed method of measurement. 2 Hellebrandt and associates used patients as subjects, but only examined intertester reliability by comparing a therapist's obtained measurements with those of an acknowledged expert. 1 Although the three studies give some insight into the potential reliability of goniometry under somewhat idealized conditions, they do not reflect the goniometric reliability one can expect in clinical practice. Even Low's suggestion that taking the means of multiple measurements of the same joint improves reliability has been questioned, 2 and Hellebrandt and her associates' suggestion that large goniometers are better than small goniometers, has not been tested. The purpose of this study was to develop a protocol that could be used to examine goniometric reliability in a physical therapy department and to use that protocol to determine the following: 1. Intratester reliability for the measurement of pas Volume 63 / Number 10, October

2 marked in 2degree increments*; 2) a goniometer with 10in movable arms, marked in 1degree increments')"; and 3) a goniometer with 6in movable arms, marked in 5degree increments. The scales on all three goniometers were covered so the therapist using the device could not see the numbers and, therefore, be influenced by the results of the measurements. The test procedure was as follows (Fig. 2): 1. A therapist first identified a patient who was suitable for the study. 2. The therapist then sought out a supervisor to monitor the test. 3. The therapist then measured the passive range of motion of the knee or elbow joint for flexion and extension six times. Each goniometer was used twice, but the same goniometer was not used config. 1. The three goniometers used in the testing prosecutively. The therapist made the measurement tocol (left to right): large,, and small by using her own technique. The supervisor gave plastic. no instructions on technique but did note the patient's position. 4. When the therapist had aligned the arms of the goniometer to her satisfaction, she gave the gonisive flexion and extension of the knee and elbow ometer to the supervisor who uncovered the scale joints with each of three commonly used goniomto read and record the measurement obtained. eters; 5. After all six measurements had been made, the supervisor found the second therapist who had 2. Intertester reliability for the measurement of pasbeen paired randomly (using a program written sive flexion and extension of the knee and elbow for a Texas Instruments SR59 calculator**) with joints with each of three commonly used goniomthe first therapist. eters; 3. Possibility of improved intertester reliability by 6. The second therapist took six measurements folusing the means of repeated measurements made lowing the same procedure as the first therapist. on the same joint with the same goniometer; and 7. The supervisor read and recorded the measure4. Interchangeability of the three commonly used ments as previously described. goniometers. Two statistical methods were used to calculate reliability coefficients. One was the classical method METHODS using the Pearson productmoment (r), which is a correlation, or an assessment of covariance. The secsubjects were 24 patients referred for physical ther ond method was suggested by Bartko,4 who demonapy at the Jewish Hospital of St. Louis, Washington strated that productmoment correlation coefficients University Medical Center. Goniometric measure can be high even with large discrepancies between ments were made by 12 physical therapists who had paired scores. This high correlation results because r graduated from five different schools and who had reflects association (covariance) between two sets of from one to four years of clinical experience (average numbers, not necessarily the agreement of the two of 2.8 years). Supervisors in the department moni sets. This second method consisted of calculating 4 tored the testing and did not take measurements. The intraclass correlation coefficients (ICCs). Agreement criterion for selecting a patient was that goniometric between multiple measures is reflected by the ICC, measurement of the patient's knee or elbow joints and the value of the correlation is the percentage of 4 6 would have been a part of the regular course of common variance among repeated measures. " If examination. The measurements for the study were goniometric measurements are to be used intermade during the patients' daily treatments. Twelve patients had their elbows measured and 12 patients had their knees measured. Depending on the pattern of involvement, the left or right extremity was meas* PC 5053, JA Preston Corp, 60 Page Rd, Clifton, NJ No International Standard Goniometer, Orthopedic ured. Equipment Co Inc, Bourbon, IN, The three goniometers (Fig. 1) were the following: Hanger Limb Co, St. Louis, MO ) a large goniometer with 12in movable arms, ** Texas Instruments, Lubbock, TX PHYSICAL THERAPY

3 RESEARCH Fig. 2. The flow chart used to conduct the study. changeably between examiners, and if these measurements are to be done serially, then agreement among repeated measures, as tested by the ICC, may be more appropriate than assessment of association or covariance. To assess intratester reliability, a therapist's first measurement with a given goniometer on a given joint was correlated with the second measurement made on the same joint by the same therapist using the same goniometer. Because all the patients were measured by two different therapists, each measurement with each type of goniometer yielded 24 pairs of scores. Similar pairings were used for the calculation of the ICC. To assess intertester reliability, three different productmoment correlations and ICCs were calculated for each goniometer. A therapist's first measurement on a joint with a given goniometer was compared with the first measurement made by the second therapist on the same joint with the same goniometer. Second measurements and the means of both measurements were similarly compared. Because two measurements, one by each therapist, were compared for each of the 12 joints, 12 paired measurements were used in each of these analyses. To determine whether intertester reliability could be improved by comparing the means of repeated measurements taken by the same therapists, three coefficients were compared. One set of coefficients (ICC and r) was calculated based on the first measurements made by the therapists. A second set of coefficients was calculated based on the second measurements made by the therapists. The third set was based on the means of the measurements made by the therapists on a given joint. To examine whether the devices could be used interchangeably (reliability among devices), the mean value each therapist obtained for a position using a given device was correlated with the mean value the same therapist obtained with the other two devices (N = 24 from the two sets of paired measurements). TABLE 1 Intratester Reliability (N = 24) Device r a a r = Pearson productmoment correlation. b ICC = Intraclass correlation coefficient. ICC b.86 In addition to the three correlation coefficients, an ICC also was calculated in this manner. The ICC allowed simultaneous comparison of all three devices. RESULTS Results show that intratester reliability for passive flexion and extension of the knee and elbow joints was high (Tab. 1). Intertester reliability was also high for these measurements with the exception of knee extension (Tab. 2). Table 2 also shows that taking the mean of multiple measures does not improve the correlation coefficient for intertester reliability more than.12. Interdevice reliability was found to be high using intraclass correlation coefficients for all positions (Tab. 3), and Pearson productmoment values were also high for all positions. DISCUSSION Regardless of the type of device used, a high degree of intratester reliability for both joints and for all four movements tested was found. This agrees with previous studies conducted outside a clinical setting. 1 " 3 Intertester reliability was high for elbow flexion, elbow extension, and knee flexion. The relatively poor intertester reliability for the measurement of knee extension (r ranged from.57 to.80) existed for all three devices. We thought that this poor reliability could have resulted from the therapists' use of different patient positions for measuring knee movements. Different positions could have led to a variable effect from the twojoint hamstring muscle limiting knee extension. To test this hypothesis, a, post hoc analysis was carried out. From records obtained at the time of the study, we determined that seven pairs of measurements were made by therapists who used the same position. Reliability coefficients and intraclass correlation coefficients were then calculated for these seven Volume 63 / Number 10, October

4 TABLE 2 Intertester Reliability (N = 12) 1 st Measurement 2nd Measurement Device r b ICC C r ICC r ICC a = Mean of first and second measurements. b r = Pearson productmoment correlation. c ICC = Intraclass correlation coefficient. TABLE 3 Interdevice Reliability (N = 24) Large Plastic a Small Plastic a a r *= Pearson productmoment correlation. b ICC = Intraclass correlation coefficient. ICC b paired measurements and for the five paired measurements where different positions were used. Examination of Table 4 shows that using the same position by both testers dramatically increased the reliability coefficient. When these coefficients for intertester reliability of knee extension were compared with the intratester coefficients, intertester reliability was still relatively poor. Using the same position improved intertester reliability, but never to a point that was comparable to intratester reliability. For most of the measures, between 15 to 20 percent of the variance can be accounted for by using the same person to measure knee extension. This finding suggests that for knee extension measurements, the same therapist should take all the measurements for the same patient's joint. The data also suggest that therapists should record the patient's position at the time measurements of knee extension are made. Of the four movements examined in this study, only intertester reliability for knee extension was poor. Because this finding was true even when positioning was accounted for, other difficulties in obtaining good intertester reliability for this movement must exist. The knee extension arc is limited, and any error might, therefore, be magnified. Determining the anatomical landmarks may be difficult in patients with pathological changes in the knee. itself may be highly labile and, therefore, hard to quantify. At least two of these hypotheses seem unlikely. is also measured in a limited arc, and intertester reliability for elbow extension was excellent. If movements into knee extension are highly labile and change with each successive passive movement, poor intratester reliability would have been observed, but this was not the case. If problems identifying bony landmarks for placing the goniometer caused the poor reliability, placement errors could occur more easily for measurements of the knee than of the elbow because of the long lever arms associated with the knee, the shank, and the thigh. We cannot say what caused poor intertester reliability for knee extension. The results strongly suggested, however, that repeated measurements of knee extension be made by the same therapist. This is in sharp contrast with the three other movements examined: elbow flexion, elbow extension, and knee flexion. For these movements, only minor improvements in reliability can be gained by having the same therapist take all measurements. The results also indicated that no greater intertester reliability is obtained when therapists use the means 1614 PHYSICAL THERAPY

5 RESEARCH of repeated measurements on the same joint. This finding contrasts with the results of Low 3 but agrees with those of Boone et al. 2 Because the present study was done in a clinical setting, the results indicated that reliability and efficiency can be served by taking a single measurement. Hellebrandt and associates strongly suggested that reliability was improved when all therapists in a department used the same goniometer. 1 They also stated that the best device was a large universal goniometer. Our results did not support either assertion. By examining the correlation matrix (Tab. 3), one can see that all the measurements obtained with the three goniometers systematically related to each other. Of even greater importance was the fact that no ICC value was lower than 9 (Tab. 3). These results demonstrated that for measurements of knee and elbow movements, all three goniometers could be used interchangeably in the physical therapy department we examined. The results on these two single axis joints cannot necessarily be generalized to other joints, which may have more degrees of freedom and may be more difficult to measure because they are either proximal (hip and shoulder) or small (fingers and ankle). The clinical reliability of goniometric assessment of other joints will require further research. This study was conducted in one physical therapy department. Although the methods used by the physical therapists to take goniometric measurements in the study were not unique, the results cannot necessarily be generalized to all departments. The protocol used in this study has been demonstrated to be feasible in a busy department and can, therefore, be used by other clinicians who want to assess goniometric reliability in their setting. In this study, multiple devices and the effects of multiple measures were examined. Clinicians interested in establishing goniometric reliability in their own setting may modify the protocol by examining only single devices with single measurements. In our experience, such a study would take no more than five minutes to conduct with each patient. Reliability is inherent to the quality of a measurement; therefore, this testing protocol can also serve as a tool to provide and document quality assurance. This study demonstrated that a high degree of reliability can be expected when a therapist measures the same knee and elbow joints. This reliability was almost equally high when other therapists measured elbow movements and knee flexion. For measurements of knee extension, reliability was high only when the same therapist took all serial measurements. This study also indicated that expensive devices were no more reliable than some inexpensive devices for measuring the knee and elbow joints and that relia TABLE 4 Reliability Coefficients for Intertester Measures of Knee Extension When the Two Testers Used the Same and Different Positions a Position Same (n = 7) Different (n = 5) Type of Goniometer r b ICC C a These coefficients are based on the first measure each tester made. Coefficients using the means of the two measurements made by each tester tended to be only slightly higher in most cases and slightly lower in a few cases. b r = Pearson productmoment correlation. c ICC = Intraclass correlation coefficient. bility and efficiency can be served by taking single measurements. CONCLUSION Goniometric measurements made in a clinical setting on the elbow and knee can be highly reliable when taken by the same therapist. Measurements taken by different therapists can also be reliable for elbow flexion and extension and for knee flexion. measurements taken by multiple therapists demonstrate poor reliability. Reliability can be obtained with single measurements made by any one of three commonly used goniometers. Goniometry can be assessed in a clinic using the protocol in this study, and goniometric assessment can be used for charting patient progress and quality assurance. Acknowledgments. The authors thank Dr. Franz Steinberg for his cooperation, Eugene Michaels and Dr. Steven J. Rose for their critical thoughts on this manuscript and for their advice on the design of this study, and the staff therapists at the Jewish Hospital of St. Louis whose efforts made this study possible. REFERENCES 1. Hellebrandt FA, Duvall EN, Moore ML: The measurement of joint motion: Part III Reliability of goniometry. Phys Ther Rev 29: , Boone DC, Azen SP, Lin CM, et al: Reliability of goniometric measurements. Phys Ther 58: , Low JL: The reliability of joint measurement. Physiotherapy 62:227229, Bartko J J, Carpenter WT: On the methods and theory of reliability. J Nerv Ment Dis 163: , Ebel RL: Estimation of the reliability of ratings. Psychometrika 16:407424, Winer BJ: Statistical Principles In Experimental Design, ed 2. New York, NY, McGrawHill Inc, 1971, pp Volume 63 / Number 10, October

OBJECTIVE AND ACCURATE measurements of lumbar

OBJECTIVE AND ACCURATE measurements of lumbar 99 Strapped Versus Unstrapped Technique of the Prone Press-Up for Measurement of Lumbar Extension Using a Tape Measure: Differences in Magnitude and Reliability of Measurements William D. Bandy, PhD, PT,

More information

DOUGLAS S. CREIGHTON, PT, BS,t VARICK L. OLSON, PT, PhD*

DOUGLAS S. CREIGHTON, PT, BS,t VARICK L. OLSON, PT, PhD* 0196-6011 /87/0807-0357$02.00/0 THE JOURNAL OF ORTHOPAEDIC AN0 SPORTS PHYSICAL THERAPY Copyright 0 1987 by The Orthopaedic and Sports Physical Therapy Sections of the American Physical Therapy Association

More information

Introduction -

Introduction - Introduction - http://www.irdpq.qc.ca/communication/publications/pdf/preliminaries.pdf Part 1 Gait : http://www.irdpq.qc.ca/communication/publications/pdf/part_1_gait.pdf Part 2 Muscle Strength and Physical

More information

The Reliability of Four Different Methods. of Calculating Quadriceps Peak Torque Angle- Specific Torques at 30, 60, and 75

The Reliability of Four Different Methods. of Calculating Quadriceps Peak Torque Angle- Specific Torques at 30, 60, and 75 The Reliability of Four Different Methods. of Calculating Quadriceps Peak Torque Angle- Specific Torques at 30, 60, and 75 By: Brent L. Arnold and David H. Perrin * Arnold, B.A., & Perrin, D.H. (1993).

More information

Relationship of the Penn Shoulder Score with Measures of Range of Motion and Strength in Patients with Shoulder Disorders: A Preliminary Report

Relationship of the Penn Shoulder Score with Measures of Range of Motion and Strength in Patients with Shoulder Disorders: A Preliminary Report The University of Pennsylvania Orthopaedic Journal 16: 39 44, 2003 2003 The University of Pennsylvania Orthopaedic Journal Relationship of the Penn Shoulder Score with Measures of Range of Motion and Strength

More information

Journal of Sport Rehabilitation. The reliability of strength tests performed in elevated shoulder positions using a hand-held dynamometer

Journal of Sport Rehabilitation. The reliability of strength tests performed in elevated shoulder positions using a hand-held dynamometer The reliability of strength tests performed in elevated shoulder positions using a hand-held dynamometer Journal: Manuscript ID: JSR.2015-0034.R2 Manuscript Type: Technical Report Keywords: dynamometry,

More information

The amount of active range of motion (AROM) for forearm

The amount of active range of motion (AROM) for forearm Reliability of 2 Functional Goniometric Methods for Measuring Forearm Pronation And Supination Active Range of Motion Christos Karagiannopoulos, MPT, MEd, ATC 1 Michael Sitler, EdD, ATC 2 Susan Michlovitz,

More information

CALIFORNIA STATE UNIVERSITY, NORTHRIDGE COMPARISON OF GONIOMETRY AND INCLINOMETRY DURING PASSIVE KNEE EXTENSION: A RELIABILITY STUDY

CALIFORNIA STATE UNIVERSITY, NORTHRIDGE COMPARISON OF GONIOMETRY AND INCLINOMETRY DURING PASSIVE KNEE EXTENSION: A RELIABILITY STUDY CALIFORNIA STATE UNIVERSITY, NORTHRIDGE COMPARISON OF GONIOMETRY AND INCLINOMETRY DURING PASSIVE KNEE EXTENSION: A RELIABILITY STUDY A thesis submitted in partial fulfillment of the requirements For the

More information

Reliability of Measuring Trunk Motions in Centimeters

Reliability of Measuring Trunk Motions in Centimeters Reliability of Measuring Trunk Motions in Centimeters MARGARET ROST, SANDRA STUCKEY, LEE ANNE SMALLEY, and GLENDA DORMAN A method of measuring trunk motion and two related motions using a tape measure

More information

lntertester and lntratester Reliability of a Dynamic Balance Protocol Using the Biodex Stability System

lntertester and lntratester Reliability of a Dynamic Balance Protocol Using the Biodex Stability System Journal of Sport Rehabilitation, 1998, 7, 95-101 0 1998 Human Kinetics Publishers, Inc. lntertester and lntratester Reliability of a Dynamic Balance Protocol Using the Biodex Stability System Randy Schmitz

More information

Effect of intermittent stretching on the maintenance of flexibility in the hamstrings

Effect of intermittent stretching on the maintenance of flexibility in the hamstrings The University of Toledo The University of Toledo Digital Repository Master s and Doctoral Projects Effect of intermittent stretching on the maintenance of flexibility in the hamstrings Pamela Spradlin

More information

Joint Range of Motion Assessment Techniques. Presentation Created by Ken Baldwin, M.Ed Copyright

Joint Range of Motion Assessment Techniques. Presentation Created by Ken Baldwin, M.Ed Copyright Joint Range of Motion Assessment Techniques Presentation Created by Ken Baldwin, M.Ed Copyright 2001-2006 Objectives Understand how joint range of motion & goniometric assessment is an important component

More information

Measurement of Elbow Range of Motion in Full Term Neonates

Measurement of Elbow Range of Motion in Full Term Neonates Volume 5 Issue 11 November-2017 Pages-7721-7731 ISSN(e):2321-7545 Website: http://ijsae.in Index Copernicus Value- 56.65 DOI: http://dx.doi.org/10.18535/ijsre/v5i11.03 Measurement of Elbow Range of Motion

More information

Motion Commotion: A Station Lab

Motion Commotion: A Station Lab Introduction: You arrive home after a hard day at school and trudge up the stairs to your room. You open the door, throw your backpack on the floor and sit down at your computer for a little quality time

More information

Factors influencing the reliability of the universal goniometer in measurement of. lower limb range of motion: a literature review

Factors influencing the reliability of the universal goniometer in measurement of. lower limb range of motion: a literature review Factors influencing the reliability of the universal goniometer in measurement of lower limb range of motion: a literature review 1 Abstract Introduction: The universal goniometer (UG) is commonly used

More information

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects Test protocol Muscle test procedures. Prior to each test participants

More information

A Comparison of Two Stretching Protocols on Hip Range of Motion: Implications for Total Daily Stretch Duration

A Comparison of Two Stretching Protocols on Hip Range of Motion: Implications for Total Daily Stretch Duration Journal of Strength and Conditioning Research, 2003, 17(2), 274 278 2003 National Strength & Conditioning Association A Comparison of Two Stretching Protocols on Hip Range of Motion: Implications for Total

More information

Examination of some physiotherapy methods for treatment of Knee joint injury

Examination of some physiotherapy methods for treatment of Knee joint injury Fatehiya F. Hasan MSc, PhD *, Elham Khald Ibraham MSc** Abstract: Objective: This study investigates different range of motion of Knee joint, the effect of age, sex, regular, irregular patients treated

More information

Validity of Data Extraction Techniques on the Kinetic Communicator (KinCom) Isokinetic Device

Validity of Data Extraction Techniques on the Kinetic Communicator (KinCom) Isokinetic Device Validity of Data Extraction Techniques on the Kinetic Communicator (KinCom) Isokinetic Device By: Laurie L. Tis, PhD, AT,C * and David H. Perrin, PhD, AT,C Tis, L.L., & Perrin, D.H. (1993). Validity of

More information

IS THERE A LINK BETWEEN SPINE AND HIP MOBILITY?

IS THERE A LINK BETWEEN SPINE AND HIP MOBILITY? EXERCISE AND QUALITY OF LIFE Volume 4, No. 2, 2012, 1-5 UDC 796.012.23 Research article IS THERE A LINK BETWEEN SPINE AND HIP MOBILITY? Miroslav Saviè and S2P, Laboratory for Motor Control and Motor Learning,

More information

i;l Contents PART I INTRODUCTIOM TO GONIOMETRY, I ~haoter '1 Basic Conceots. 3 Chapter 2 Procedures, 19 Chapter 3 Validity and Reliability, 39

i;l Contents PART I INTRODUCTIOM TO GONIOMETRY, I ~haoter '1 Basic Conceots. 3 Chapter 2 Procedures, 19 Chapter 3 Validity and Reliability, 39 w Contents i;l PART I INTRODUCTIOM TO GONIOMETRY, I ~haoter '1 Basic Conceots. 3 Goniometry, 3 Joint Motion, 4 Arthrokinematics, 4 Osteokinematics, 5 Planes and Axes, 5 Range of Motion, 6 Active Range

More information

Can Muscle Power Be Estimated From Thigh Bulk Measurements? A Preliminary Study

Can Muscle Power Be Estimated From Thigh Bulk Measurements? A Preliminary Study Journal of Sport Rehabilitation, 1999, 8.50-59 O 1999 Human Kinetics Publishers, Inc. Can Muscle Power Be Estimated From Thigh Bulk Measurements? A Preliminary Study Eric Maylia, John A. Fairclough, Leonard

More information

Measurement of passive ankle dorsiflexion: Procedure and reliability

Measurement of passive ankle dorsiflexion: Procedure and reliability Anne Moseley Roger Adams Measurement of passive ankle dorsiflexion: Procedure and reliability The purpose of this study was to develop a reliable procedure to measure passive ankle dorsiflexion in the

More information

Title: Reliability and Accuracy of Knee Goniometry Methods. Abstract

Title: Reliability and Accuracy of Knee Goniometry Methods. Abstract Title: Reliability and Accuracy of Knee Goniometry Methods Abstract Background The accuracy of measurement of angles around the knee is important both for research and for monitoring patient progress after

More information

Measurement of Selected Hip, Knee, and Ankle Joint Motions in Newborns

Measurement of Selected Hip, Knee, and Ankle Joint Motions in Newborns Measurement of Selected Hip, Knee, and Ankle Joint Motions in Newborns KELLY GILMORE WAUGH, JEAN L. MINKEL, ROCHELLE PARKER, and VALERIE A. COON As clinicians become more involved in preventative screening,

More information

Chapter 20: Muscular Fitness and Assessment

Chapter 20: Muscular Fitness and Assessment Chapter 20: Muscular Fitness and Assessment American College of Sports Medicine. (2010). ACSM's resource manual for guidelines for exercise testing and prescription (6th ed.). New York: Lippincott, Williams

More information

Goniometry. Wrist Flexion: Pt seated with forearm resting on table (use olecranon process & midline of ulna as reference for stationary arm)

Goniometry. Wrist Flexion: Pt seated with forearm resting on table (use olecranon process & midline of ulna as reference for stationary arm) Goniometry Wrist Flexion: Pt seated with forearm resting on table (use olecranon process & midline of ulna as reference for stationary arm) Wrist Extension: Pt seated with forearm resting on table (Goniometer

More information

Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards.

Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards. Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards. Prepared by Engineering and Human Performance Lab Department of

More information

Dynamic Splinting of the

Dynamic Splinting of the Dynamic Splinting of the Rheumatoid Hand BY F. RICHARD CONVERY, M.D.,* J. PIERCE CONATY, M.D.** AND VERNON L. NICKEL, M.D.** Rancho Los Amigos Hospital, Downey, California (University of Southern California

More information

A Comparison of the Immediate Effects of Eccentric Training vs Static Stretch on Hamstring Flexibility in Basketball Players Dr.

A Comparison of the Immediate Effects of Eccentric Training vs Static Stretch on Hamstring Flexibility in Basketball Players Dr. A Comparison of the Immediate Effects of Eccentric Training vs Static Stretch on Hamstring Flexibility in Basketball Players Dr. Mandeep Thour* *Assistant Professor, Department of Physical Education SGGS

More information

Chapter 4B: Reliability Trial 2. Chapter 4B. Reliability. General issues. Inter-rater. Intra - rater. Test - Re-test

Chapter 4B: Reliability Trial 2. Chapter 4B. Reliability. General issues. Inter-rater. Intra - rater. Test - Re-test Chapter 4B: Reliability Trial 2 Chapter 4B Reliability General issues Inter-rater Intra - rater Test - Re-test Trial 2 The second clinical trial was conducted in the spring of 1992 using SPCM Draft 6,

More information

Introduction -

Introduction - Introduction - http://www.irdpq.qc.ca/communication/publications/pdf/preliminaries.pdf Part 1 Gait : http://www.irdpq.qc.ca/communication/publications/pdf/part_1_gait.pdf Part 2 Muscle Strength and Physical

More information

Intramachine and intermachine reproducibility of concentric performance: A study of the Con-Trex MJ and the Cybex Norm dynamometers

Intramachine and intermachine reproducibility of concentric performance: A study of the Con-Trex MJ and the Cybex Norm dynamometers Isokinetics and Exercise Science 12 (4) 91 97 91 IOS Press Intramachine and intermachine reproducibility of concentric performance: A study of the Con-Trex MJ and the Cybex Norm dynamometers C. Bardis

More information

Reliability of the Ely s Test for Assessing Rectus Femoris Muscle Flexibility and Joint Range of Motion

Reliability of the Ely s Test for Assessing Rectus Femoris Muscle Flexibility and Joint Range of Motion Reliability of the Ely s Test for Assessing Rectus Femoris Muscle Flexibility and Joint Range of Motion J. Peeler, 1 J.E. Anderson 2 1 Department of Kinesiology and Applied Health, University of Winnipeg,

More information

Goniometry: is it a reliable tool to monitor passive joint range of motion in horses?

Goniometry: is it a reliable tool to monitor passive joint range of motion in horses? evj_254 676..682 676 EQUINE VETERINARY JOURNAL Equine vet. J. (2010) 42 (Suppl. 38) 676-682 doi: 10.1111/j.2042-3306.2010.00254.x Goniometry: is it a reliable tool to monitor passive joint range of motion

More information

Comparison of functional training and strength training in improving knee extension lag after first four weeks of total knee replacement.

Comparison of functional training and strength training in improving knee extension lag after first four weeks of total knee replacement. Biomedical Research 2017; 28 (12): 5623-5627 ISSN 0970-938X www.biomedres.info Comparison of functional training and strength training in improving knee extension lag after first four weeks of total knee

More information

Title: Rotational strength, range of motion, and function in people with unaffected shoulders from various stages of life

Title: Rotational strength, range of motion, and function in people with unaffected shoulders from various stages of life Author's response to reviews Title: Rotational strength, range of motion, and function in people with unaffected shoulders from various stages of life Authors: Jean-Sébastien Roy (jean-sebastien.roy.1@ulaval.ca)

More information

PTA 2. Kinesiology and Applied Anatomy

PTA 2. Kinesiology and Applied Anatomy PTA 2 Kinesiology and Applied Anatomy SYLLABUS AND COURSE INFORMATION PACKET Spring 2018 4 credits Prof. Michael Mattia PT DPT MS 2 hour lecture/4 hours lab Office: S-128 Phone: 718 368-4818 Email: michael.mattia12@kbcc.cuny.edu

More information

Validity and Reliability of Electrogoniometer in Musculoskeletal Injury/Disorder ROM Assessment

Validity and Reliability of Electrogoniometer in Musculoskeletal Injury/Disorder ROM Assessment Evidence-Based Practice Group Answers to Clinical Questions Validity and Reliability of Electrogoniometer in Musculoskeletal Injury/Disorder ROM Assessment By WorkSafeBC Evidence-Based Practice Group Dr.

More information

TOOLS TO IMPROVE CLINICAL REASONING FOR ASSESSMENT & TREATMENT Presented By: Michelle Green, PT, DPT, c/ndt, NCS

TOOLS TO IMPROVE CLINICAL REASONING FOR ASSESSMENT & TREATMENT Presented By: Michelle Green, PT, DPT, c/ndt, NCS TOOLS TO IMPROVE CLINICAL REASONING FOR ASSESSMENT & TREATMENT Presented By: Michelle Green, PT, DPT, c/ndt, NCS Carolina Clinical Education Consortium Spring Conference 2018 OBJECTIVES: Following completion

More information

Effect of Preload and Range of Motion on Isokinetic Torque in Women

Effect of Preload and Range of Motion on Isokinetic Torque in Women Effect of Preload and Range of Motion on Isokinetic Torque in Women By: Laurie L. Tis, David H. Perrin, Arthur Weltman, Donald W. Ball, and Joe H. Gieck * Tis, L.L., Perrin, D.H., Weltman, A., Ball, D.W.,

More information

Fulfill your potential

Fulfill your potential Fulfill your potential Clinical Concept and Advanced Technologies MediTouch creates innovative physical rehabilitation solutions for hospital, community clinic and home care use. The unique patented products

More information

Relative Isometric Force of the Hip Abductor and Adductor Muscles

Relative Isometric Force of the Hip Abductor and Adductor Muscles Relative Isometric Force of the Hip Abductor and Adductor Muscles WARREN W. MAY, Captain, AMSC A-LTHOUGH THE CONCEPT of the muscular force curve is not new, its clinical application has been generally

More information

PTA Applied Kinesiology 1

PTA Applied Kinesiology 1 Western Technical College 10524156 PTA Applied Kinesiology 1 Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Introduces basic principles of musculoskeletal

More information

Assessment protocol of limb muscle strength in critically ill. patients admitted to the ICU: Dynamometry

Assessment protocol of limb muscle strength in critically ill. patients admitted to the ICU: Dynamometry Assessment protocol of limb muscle strength in critically ill patients admitted to the ICU: Dynamometry To proceed to voluntary muscle strength assessment, the neurologic en hemodynamic stability of the

More information

Dynamic Stretching Program augmented by self-myofascial Release on Knee Flexion

Dynamic Stretching Program augmented by self-myofascial Release on Knee Flexion Dynamic Stretching Program augmented by self-myofascial Release on Knee Flexion Passive Motion and Sprint Speed Context: Stretching techniques as well as self-myofascial release (self-mfr) have recently

More information

An Objective Measurement Technique for

An Objective Measurement Technique for An Objective Measurement Technique for - Posterior Scapular Displacement Dean M. Plafcan, MS, ATC, SPT Patricia ). Turczany, MS, ATC, SPT* Blaine A. Guenin, MS, SPT 3t6 Sam Kegerreis, MS, PT, ATC4 Teddy

More information

This copy is for personal use only - distribution prohibited.

This copy is for personal use only - distribution prohibited. PMID: 17599027 Received: 2006.02.18 Accepted: 2007.01.10 Published: 2007.07.01 Authors Contribution: A Study Design B Data Collection C Statistical Analysis D Data Interpretation E Manuscript Preparation

More information

Reliability of Popliteal Angle Measurement. A Study in Cerebral Palsy Patients and Healthy Controls

Reliability of Popliteal Angle Measurement. A Study in Cerebral Palsy Patients and Healthy Controls ORIGINAL ARTICLE A Study in Cerebral Palsy Patients and Healthy Controls Sabine R. ten Berge, MD,*Þ Jan P.K. Halbertsma, PhD,*Þ Patrick G.M. Maathuis, MD,þ Nienke P. Verheij, MSc,*Þ Pieter U. Dijkstra,

More information

Inter- and lntratester Reliability of Measuring Neck Motions with Tape Measure and ~yrin" Gravity- Reference Goniometer

Inter- and lntratester Reliability of Measuring Neck Motions with Tape Measure and ~yrin Gravity- Reference Goniometer Inter- and lntratester Reliability of Measuring Neck Motions with Tape Measure and ~yrin" Gravity- Reference Goniometer JOSEPH A. BALOGUN, PhD, PT, MNSP,' OLADEHINDE K. ABEREOJE, MEd, MNSP? MATTHEW 0.

More information

The Reliability and Concurrent Validity of the Figure-of-Eight Method of Measuring Hand Edema in Patients with Burns

The Reliability and Concurrent Validity of the Figure-of-Eight Method of Measuring Hand Edema in Patients with Burns The Reliability and Concurrent Validity of the Figure-of-Eight Method of Measuring Hand Edema in Patients with Burns William S. Dewey, PT, OCS, CHT, Travis L. Hedman, MPT, OCS, Ted T. Chapman, OTR/L, Steven

More information

The iliotibial (IT) tract,

The iliotibial (IT) tract, Use of an Inclinometer to Measure Flexibility of the Iliotibial Band Using the Ober Test and the Modified Ober Test: Differences in Magnitude and Reliability of Measurements Nancy B. Reese, PT, PhD 1 William

More information

Obesity is associated with reduced joint range of motion (Park, 2010), which has been partially

Obesity is associated with reduced joint range of motion (Park, 2010), which has been partially INTRODUCTION Obesity is associated with reduced joint range of motion (Park, 2010), which has been partially attributed to adipose tissues around joints limiting inter-segmental rotations (Gilleard, 2007).

More information

MMT measurements are acceptable in routine clinical practice: Results from periodic medical examinations of polio survivors

MMT measurements are acceptable in routine clinical practice: Results from periodic medical examinations of polio survivors 51 Japanese Journal of Comprehensive Rehabilitation Science (2017) Original Article MMT measurements are acceptable in routine clinical practice: Results from periodic medical examinations of polio survivors

More information

EVect of stretching duration on active and passive range of motion in the lower extremity

EVect of stretching duration on active and passive range of motion in the lower extremity Br J Sports Med 1999;33:259 263 259 School of Health Sciences, University of Sunderland J M Roberts K Wilson Correspondence to: J M Roberts, School of Health Sciences, University of Sunderland, Chester

More information

Validity Study of Head and Neck Flexion-Extension Motion Comparing Measurements of a Pendulum Goniometer and Roentgenograms1

Validity Study of Head and Neck Flexion-Extension Motion Comparing Measurements of a Pendulum Goniometer and Roentgenograms1 Validity Study of Head and Neck Flexion-Extension Motion Comparing Measurements of a Pendulum Goniometer and Roentgenograms1 DENYSE BREDENKAMP HERRMANN, MHS, P? Physical therapists measure head and neck

More information

EVALUATION OF THE ANKLE ROLL GUARD S EFFECTIVENESS TO IMPROVE ITS CLINICAL BENEFIT PROGRESS REPORT. Prepared By:

EVALUATION OF THE ANKLE ROLL GUARD S EFFECTIVENESS TO IMPROVE ITS CLINICAL BENEFIT PROGRESS REPORT. Prepared By: EVALUATION OF THE ANKLE ROLL GUARD S EFFECTIVENESS TO IMPROVE ITS CLINICAL BENEFIT PROGRESS REPORT Prepared By: Dr. Tyler Brown, Principal Investigator Wyatt Ihmels, Graduate Research Assistant Research

More information

Total Hip Replacement Rehabilitation: Progression and Restrictions

Total Hip Replacement Rehabilitation: Progression and Restrictions Total Hip Replacement Rehabilitation: Progression and Restrictions The success of total hip replacement (THR) is a result of predictable pain relief, improvements in quality of life, and restoration of

More information

Journal of Rehabilitation Sciences and Research. The Reliability of Smartphone and Goniometric Measurements of Hip Range of Motion

Journal of Rehabilitation Sciences and Research. The Reliability of Smartphone and Goniometric Measurements of Hip Range of Motion JRSR 4 (2016) 77-84 Journal of Rehabilitation Sciences and Research Journal Home Page: jrsr.sums.ac.ir Original Article The Reliability of Smartphone and Goniometric Measurements of Hip Range of Motion

More information

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults Original Article https://doi.org/10.14474/ptrs.2017.6.2.65 pissn 2287-7576 eissn 2287-7584 Phys Ther Rehabil Sci 2017, 6 (2), 65-70 www.jptrs.org The reliability of the nonradiologic measures of thoracic

More information

Bioscience Research Print ISSN: Online ISSN:

Bioscience Research Print ISSN: Online ISSN: Available online freely at www.isisn.org Bioscience Research Print ISSN: 1811-9506 Online ISSN: 2218-3973 Journal by Innovative Scientific Information & Services Network RESEARCH ARTICLE BIOSCIENCE RESEARCH,

More information

Analysis of a Modified Active Knee Extension Test

Analysis of a Modified Active Knee Extension Test Analysis of a Modified Active Knee Extension Test Yvonne Kane, MS, PT' lay Bernasconi, MS, PT2 P hysical therapists frequently assess hamstring muscle length (HML) in patients with hamstring injuries,

More information

Lever system. Rigid bar. Fulcrum. Force (effort) Resistance (load)

Lever system. Rigid bar. Fulcrum. Force (effort) Resistance (load) Lever system lever is any elongated, rigid (bar) object that move or rotates around a fixed point called the fulcrum when force is applied to overcome resistance. Force (effort) Resistance (load) R Rigid

More information

Orthotics Measurement Board for Tibial Torsion and Toe-Out

Orthotics Measurement Board for Tibial Torsion and Toe-Out Orthotics Measurement Board for Tibial Torsion and Toe-Out HANS R. LEHNEIS, C.P.O. 2 COORDINATED function of the brace-anatomical complex is dependent upon the configuration and fit of the brace with the

More information

Intertester Reliability of Assessing Postural Sway Using the Chattecx Balance System

Intertester Reliability of Assessing Postural Sway Using the Chattecx Balance System Intertester Reliability of Assessing Postural Sway Using the Chattecx Balance System By: Carl G. Mattacola, MEd, ATC; Denise A. Lebsack, PhD, ATC; David H. Perrin, PhD, ATC * Mattacola, C.G., Lebsack,

More information

Reliability of radiographic measurements of knee motion following knee arthroplasty for use in a virtual knee clinic

Reliability of radiographic measurements of knee motion following knee arthroplasty for use in a virtual knee clinic ORTHOPAEDIC SURGERY doi 10.1308/003588412X13373405385575 Reliability of radiographic measurements of knee motion following knee arthroplasty for use in a A Phillips, A Goubran, S Naim, D Searle, V Mandalia,

More information

THE CORRELATION BETWEEN FOUR CLINICAL TRIALS FOR MEASUREMENT OF HAMSTRING MUSCLE FLEXIBILITY

THE CORRELATION BETWEEN FOUR CLINICAL TRIALS FOR MEASUREMENT OF HAMSTRING MUSCLE FLEXIBILITY ISSN: 2186-2982 (P), 2186-2990 (O), Japan, DOI: https://doi.org/10.21660/2019.55.3652 Special Issue on Science, Engineering & Environment THE CORRELATION BETWEEN FOUR CLINICAL TRIALS FOR MEASUREMENT OF

More information

Effects of Ankle Dorsiflexion on Active and Passive Unilateral Straight Leg Raising

Effects of Ankle Dorsiflexion on Active and Passive Unilateral Straight Leg Raising Effects of Ankle Dorsiflexion on Active and Passive Unilateral Straight Leg Raising RICHARD L. GAJDOSIK, BARNEY F. LEVEAU, and RICHARD W. BOHANNON The purpose of this study was to analyze the straight-leg-raising

More information

Int J Physiother. Vol 1(4), , October (2014) ISSN:

Int J Physiother. Vol 1(4), , October (2014) ISSN: Int J Physiother. Vol 1(4), 195-199, October (214) ISSN: 2348-8336 1 Jibi Paul 2 Pradeep Balakrishnan 3 Mohd Izham ABSTRACT Background: Stretching exercises have been routinely used in persons with hamstring

More information

Radiographic Procedures 1

Radiographic Procedures 1 Western Technical College 10526149 Radiographic Procedures 1 Course Outcome Summary Course Information Textbooks Description Career Cluster Instructional Level Total Credits 5 Prepares radiography students

More information

Discrepancies in Knee Joint Moments Using Common Anatomical Frames Defined by Different Palpable Landmarks

Discrepancies in Knee Joint Moments Using Common Anatomical Frames Defined by Different Palpable Landmarks Journal of Applied Biomechanics, 2008, 24, 185-190 2008 Human Kinetics, Inc. Discrepancies in Knee Joint Moments Using Common Anatomical Frames Defined by Different Palpable Landmarks Dominic Thewlis,

More information

Skeletal System. Std. VIII

Skeletal System. Std. VIII Skeletal System Std. VIII The skeleton in our body serves following functions : 1. Support and shape : The skeleton provides a support or framework to all the soft parts and gives the body and its parts

More information

Adaptive shortening of long flexor in patients with claw hand: A short report

Adaptive shortening of long flexor in patients with claw hand: A short report Lepr Rev (2016) 87, 548 552 SHORT REPORT Adaptive shortening of long flexor in patients with claw hand: A short report PANKAJ GUPTA*, KENNETH KEVIN JOSHUA* & TASMIN JAHAN* *The Leprosy Mission Community

More information

ASSESSMENT OF STRENGTH IN CHILDREN WITH JUVENILE DERMATOMYOSITIS

ASSESSMENT OF STRENGTH IN CHILDREN WITH JUVENILE DERMATOMYOSITIS ASSESSMENT OF STRENGTH IN CHILDREN WITH JUVENILE DERMATOMYOSITIS CURE JM STANFORD SCHOOL OF MEDICINE OCTOBER 3, 2014 Minal Jain, PT, DSc, PCS Research Coordinator, Physical Therapy Section Rehabilitation

More information

International Journal of Medical and Exercise Science (Multidisciplinary, Peer Reviewed and Indexed Journal)

International Journal of Medical and Exercise Science (Multidisciplinary, Peer Reviewed and Indexed Journal) ORIGINAL ARTICLE International Journal of Medical and Exercise Science (Multidisciplinary, Peer Reviewed and Indexed Journal) EFFECTIVENESS OF MYOFASCIAL RELEASE IN REDUCTION OF HAMSTRINGS SPASTICITY AMONG

More information

Among the non-operative methods, serial or wedge casting of the patient's arm in forced extension has been used with success. However, the weight and

Among the non-operative methods, serial or wedge casting of the patient's arm in forced extension has been used with success. However, the weight and A Modular, Prefabricated Orthosis for Treatment of Elbow Flexion Contractures 1 S.I. REGER, PH.D., C.P. 2 J. O'REAGAN 2 M.H. BO-BLITZ2 R.W. ROSENBERGER, C.P. 2 A simple and adjustable orthosis has been

More information

Reliability of Stationary Dynamometer Muscle Strength Testing in Community-Dwelling Older Adults

Reliability of Stationary Dynamometer Muscle Strength Testing in Community-Dwelling Older Adults 1128 Reliability of Stationary Dynamometer Muscle Strength Testing in Community-Dwelling Older Adults Cheryl D. Ford-Smith, PT, MS, NCS, Jean F. Wyman, PhD, RN, R.K. Elswick Jr, PhD, Theresa Fernandez,

More information

A Reliability Study of Measurement Techniques to Determine Static Scapular Position

A Reliability Study of Measurement Techniques to Determine Static Scapular Position A Reliability Study of Measurement Techniques to Determine Static Scapular Position Mark H. Gibson, MS, PT, ATC1l6 Gerald V. Goebel, MS, PT*,~ Terry M. lordan, MS, PT, A TC 3,6 Sam Kegerreis, MS, PT, ATC4

More information

3D SSPP Version 6. ANALYSIS & USE GUIDE For Reactive & Proactive Use

3D SSPP Version 6. ANALYSIS & USE GUIDE For Reactive & Proactive Use 3D SSPP Version 6 ANALYSIS & USE GUIDE For Reactive & Proactive Use REQUIREMENTS The user must complete the UAW-GM 3D SSPP training course offered through the UAW- GM Center for Human Resources for the

More information

The Cun Measurement System: an Investigation into its Suitability in Current Practice

The Cun Measurement System: an Investigation into its Suitability in Current Practice The Measurement System: an Investigation into its Suitability in Current Practice Meaghan Coyle, Mark Aird, DM Cobbin, C Zaslawski This article is based on a paper presented at the Fifth Australasian Acupuncture

More information

Peak Torque Comparison between isam 9000 and Biodex Isokinetic Devices

Peak Torque Comparison between isam 9000 and Biodex Isokinetic Devices International Journal of Health Sciences September 2016, Vol. 4, No. 3, pp. 7-13 ISSN: 2372-5060 (Print), 2372-5079 (Online) Copyright The Author(s). All Rights Reserved. Published by American Research

More information

Unraveling the Mystery of Cervical Pain #3: TP7 Ligament Sprains

Unraveling the Mystery of Cervical Pain #3: TP7 Ligament Sprains Unraveling the Mystery of Cervical Pain #3: TP7 Ligament Sprains Instructor: Ben Benjamin, Ph.D. Instructor: Ben Benjamin, Ph.D. ben@benbenjamin.com 1 Webinar Goal Explore the assessment and treatment

More information

Comparing Vertical and Horizontal Scoring of Open-Ended Questionnaires

Comparing Vertical and Horizontal Scoring of Open-Ended Questionnaires A peer-reviewed electronic journal. Copyright is retained by the first or sole author, who grants right of first publication to the Practical Assessment, Research & Evaluation. Permission is granted to

More information

Relationship between Hip Extension Range of Motion and Postural Alignment

Relationship between Hip Extension Range of Motion and Postural Alignment Relationship between Hip Extension Range of Motion and Postural Alignment JACKLYN G. HEINO, PT,' JOSEPH J. GODGES, PT, 0CS,2 CHARLES L. PhD, PT3 Journal of Orthopaedic & Sports Physical Therapy The purpose

More information

Sensitivity and Specificity of the Minimal Chair Height Standing Ability Test: A Simple and Affordable Fall-Risk Screening Instrument

Sensitivity and Specificity of the Minimal Chair Height Standing Ability Test: A Simple and Affordable Fall-Risk Screening Instrument Sensitivity and Specificity of the Minimal Chair Height Standing Ability Test: A Simple and Affordable Fall-Risk Screening Instrument By: Nadia C. Reider, MSc ; Patti-Jean Naylor, PhD ; Catherine Gaul,

More information

The Immediate Effects of Dorsiflexion Resisted Walking on Ankle Mobility, Muscle Recruitment and Gait Velocity: A Pilot Study

The Immediate Effects of Dorsiflexion Resisted Walking on Ankle Mobility, Muscle Recruitment and Gait Velocity: A Pilot Study The Immediate Effects of Dorsiflexion Resisted Walking on Ankle Mobility, Muscle Recruitment and Gait Velocity: A Pilot Study Eric G. Johnson, DSc, PT, NCS 1 Everett B. Lohman, DSc, PT, OCS 1 Abel Rendon,

More information

DEEP SQUAT. Upper torso is parallel with tibia or toward vertical Femur below horizontal Knees are aligned over feet Dowel aligned over feet

DEEP SQUAT. Upper torso is parallel with tibia or toward vertical Femur below horizontal Knees are aligned over feet Dowel aligned over feet APPENDIX 9 SCORING CRITERIA DEEP SQUAT Upper torso is parallel with tibia or toward vertical Femur below horizontal Knees are aligned over feet Dowel aligned over feet Upper torso is parallel with tibia

More information

Intratester and Intertester Reliability and Validity of Measures of lnnominate Bone Inclination

Intratester and Intertester Reliability and Validity of Measures of lnnominate Bone Inclination Intratester and Intertester Reliability and Validity of Measures of lnnominate Bone Inclination Richard D. Crowell, MS, PT' Cordon S. Cummings, MA, PT2 /. Randy Walker, PhD, PT3 larry I. Tillman, PhD4

More information

Manual Muscle Testing. Yasser Moh. Aneis, PhD, MSc., PT. Lecturer of Physical Therapy Basic Sciences Department

Manual Muscle Testing. Yasser Moh. Aneis, PhD, MSc., PT. Lecturer of Physical Therapy Basic Sciences Department Manual Muscle Testing Yasser Moh. Aneis, PhD, MSc., PT. Lecturer of Physical Therapy Basic Sciences Department Manual Muscle Testing Evaluation of the function and strength of individual muscles and muscles

More information

Research Report. Key Words: Functional status; Orthopedics, general; Treatment outcomes. Neva J Kirk-Sanchez. Kathryn E Roach

Research Report. Key Words: Functional status; Orthopedics, general; Treatment outcomes. Neva J Kirk-Sanchez. Kathryn E Roach Research Report Relationship Between Duration of Therapy Services in a Comprehensive Rehabilitation Program and Mobility at Discharge in Patients With Orthopedic Problems Background and Purpose. The purpose

More information

Specificity of Speed of Exercise. MARY T. MOFFROID, M.A. and ROBERT H. WHIPPLE, B.A PHYSICAL THERAPY

Specificity of Speed of Exercise. MARY T. MOFFROID, M.A. and ROBERT H. WHIPPLE, B.A PHYSICAL THERAPY Resistive exercise is employed to increase functional performance. Weight lifting has been the traditional program of resistive exercise to increase muscular force (strength). Ten years ago Hellebrandt

More information

Electronic Supplementary Materials

Electronic Supplementary Materials Electronic Supplementary Materials Study 1 Body Measurements. To find proxies of lifting strength that could later be used in laboratory settings without cumbersome weight-lifting equipment, a variety

More information

ASSESSMENT OF FLEXIBILITY

ASSESSMENT OF FLEXIBILITY Name: Date ASSESSMENT OF FLEXIBILITY Objective The purpose of this lab is to gain an assessment of the participant s flexibility. A number of key joints and movement patterns will be assessed to gain an

More information

Research in Physical Medicine and Rehabilitation

Research in Physical Medicine and Rehabilitation Research in Physical Medicine and Rehabilitation IV. Some Practical Designs in Applied Research RICHARD P. REILLY, PHD AND THOMAS W. FINDLEY, MD, PHD The randomized controlled trial is often difficult,

More information

THE EXTREMITY SCREEN MANUAL: A Guide to the Subjective and Objective Outcomes Assessment of the Upper and Lower Extremity

THE EXTREMITY SCREEN MANUAL: A Guide to the Subjective and Objective Outcomes Assessment of the Upper and Lower Extremity THE EXTREMITY SCREEN MANUAL: A Guide to the Subjective and Objective Outcomes Assessment of the Upper and Lower Extremity Steven G. Yeomans, DC, FACO INTRODUCTION: Objective screen for the extremities

More information

=0.96 to 0.99) and a lower SEM compared to the goniometer (ICC 2,3

=0.96 to 0.99) and a lower SEM compared to the goniometer (ICC 2,3 IJSPT ORIGINAL RESEARCH RELIABILITY OF THREE MEASURES OF ANKLE DORSIFLEXION RANGE OF MOTION Megan M. Konor 1 Sam Morton, MS, CSCS, USAW 1 Joan M. Eckerson, PhD, FACSM, FNSCA, CSCS 1 Terry L. Grindstaff,

More information

Comparison of N-K Table Offset Angles with the Human Knee Flexor Torque Curve

Comparison of N-K Table Offset Angles with the Human Knee Flexor Torque Curve Comparison of N-K Table Offset Angles with the Human Knee Flexor Torque Curve By: Daniel J. LaPlaca *, Douglas R. Keskula, Kristinn I. Heinrichs, and David H. Perrin LaPlaca, D.J., Keskula, D., Heinrichs,

More information

Open and Closed Chained Activity Effect on Shoulder External Rotation Range of Motion using Whole Body Vibration Therapy

Open and Closed Chained Activity Effect on Shoulder External Rotation Range of Motion using Whole Body Vibration Therapy Open and Closed Chained Activity Effect on Shoulder External Rotation Range of Motion using Whole Body Vibration Therapy Timothy L. Cooley, MS, ATC University of Utah Craig L. Switzler, MS, ATC University

More information

Post-op / Pre-op Page (ALREADY DONE)

Post-op / Pre-op Page (ALREADY DONE) Post-op / Pre-op Page (ALREADY DONE) We offer individualized treatment plans based on your physician's recommendations, our evaluations, and your feedback. Most post-operative and preoperative rehabilitation

More information

X-ray (Radiography) - Bone

X-ray (Radiography) - Bone Scan for mobile link. X-ray (Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones or

More information